Testing is an essential activity in any engineer's career. Whatever your role in industry (electrical designer, purchase engineer, manufacturer, installation contractor or maintenance engineer) a solid knowledge of tests to be carried out on a given piece of electrical equipment and interpretation of results obtained is a necessity.
This manual is designed to familiarise you with various aspects of testing general electrical equipment and high voltage testing in particular. Examples are cited from various international standards regarding the procedure for conducting of tests and interpreting the test results. The need for keeping proper records of tests conducted both in the initial stages and later during routine maintenance is discussed. Some of the tests are too complex to be performed on a routine basis or may require specialised equipment which may not be normally available to user industries or even manufacturers. This is where the services of an independent and accredited test lab is useful. The role of such labs is briefly discussed.
MORE INFORMATION: http://www.idc-online.com/content/practical-medium-high-voltage-testing-electrical-equipment-engineers-and-technicians-47?id=138
Practical Medium and High voltage Testing of Electrical Equipment for Enginee...Living Online
Testing is an essential activity in any engineer’s career. Whatever your role in industry (electrical designer, purchase engineer, manufacturer, installation contractor or maintenance engineer) a solid knowledge of tests to be carried out on a given piece of electrical equipment and interpretation of results obtained is a necessity. This workshop is designed to familiarise you with various aspects of testing general electrical equipment and high voltage testing in particular.
Examples will be cited from various international standards regarding the procedure for conducting of tests and interpreting the test results. The need for keeping proper records of tests conducted both in the initial stages and later during routine maintenance will be discussed. Some of the tests are too complex to be performed on a routine basis or may require specialised equipment which may not be normally available to user industries or even manufacturers. This is where the services of an independent and accredited test lab is useful. The role of such labs will be briefly discussed.
WHO SHOULD ATTEND?
Building service designers
Consulting engineers
Control engineers
Data systems planners and managers
Electrical engineers
Electrical technicians
Instrumentation engineers
Instrumentation technicians
Maintenance engineers
Power system protection engineers
Project engineers
MORE INFORMATION: http://www.idc-online.com/content/practical-medium-high-voltage-testing-electrical-equipment-engineers-and-technicians-48
This Presentation is about l.v switch gear design, presented during the graduation project final discussion 15/7/2018.
It presented a good summary of switch gear components and types and practicing on AL.HAMOOL W.T.P M.D.B design using SIEMENS SIVACON S8
Practical Medium and High voltage Testing of Electrical Equipment for Enginee...Living Online
Testing is an essential activity in any engineer’s career. Whatever your role in industry (electrical designer, purchase engineer, manufacturer, installation contractor or maintenance engineer) a solid knowledge of tests to be carried out on a given piece of electrical equipment and interpretation of results obtained is a necessity. This workshop is designed to familiarise you with various aspects of testing general electrical equipment and high voltage testing in particular.
Examples will be cited from various international standards regarding the procedure for conducting of tests and interpreting the test results. The need for keeping proper records of tests conducted both in the initial stages and later during routine maintenance will be discussed. Some of the tests are too complex to be performed on a routine basis or may require specialised equipment which may not be normally available to user industries or even manufacturers. This is where the services of an independent and accredited test lab is useful. The role of such labs will be briefly discussed.
WHO SHOULD ATTEND?
Building service designers
Consulting engineers
Control engineers
Data systems planners and managers
Electrical engineers
Electrical technicians
Instrumentation engineers
Instrumentation technicians
Maintenance engineers
Power system protection engineers
Project engineers
MORE INFORMATION: http://www.idc-online.com/content/practical-medium-high-voltage-testing-electrical-equipment-engineers-and-technicians-48
This Presentation is about l.v switch gear design, presented during the graduation project final discussion 15/7/2018.
It presented a good summary of switch gear components and types and practicing on AL.HAMOOL W.T.P M.D.B design using SIEMENS SIVACON S8
Unit I: Introduction to Protection System:
Introduction to protection system and its elements, functions of protective relaying, protective zones, primary and backup protection, desirable qualities of protective relaying, basic terminology.
Relays:
Electromagnetic, attracted and induction type relays, thermal relay, gas actuated relay, design considerations of electromagnetic relay.
Unit-II: Relay Application and Characteristics:
Amplitude and phase comparators, over current relays, directional relays, distance relays, differential relay.
Static Relays: Comparison with electromagnetic relay, classification and their description, over current relays, directional relay, distance relays, differential relay.
Unit-III Protection of Transmission Line:
Over current protection, distance protection, pilot wire protection, carrier current protection, protection of bus, auto re-closing,
Unit-IV: Circuit Breaking:
Properties of arc, arc extinction theories, re-striking voltage transient, current chopping, resistance switching, capacitive current interruption, short line interruption, circuit breaker ratings.
Testing Of Circuit Breaker: Classification, testing station and equipments, testing procedure, direct and indirect testing.
Unit-V Apparatus Protection:
Protection of Transformer, generator and motor.
Circuit Breaker: Operating modes, selection of circuit breakers, constructional features and operation of Bulk Oil, Minimum Oil, Air Blast, SF6, Vacuum and d. c. circuit breakers.
Blind Spots of Low Voltage Testing Webinar Presented by Megger BakerTranscat
Find faults where they begin, not where they end.
When the highest reliability is demanded of your motors, high voltage testing is not just an option - it's a necessity. This webinar will focus on the theory and application of electric motor insulation testing techniques.
Importance on switchgear, its teatings commesioning
saving on losses instad of using stat delta starter use of VFDs with same operation but savings in losses
Unit I: Introduction to Protection System:
Introduction to protection system and its elements, functions of protective relaying, protective zones, primary and backup protection, desirable qualities of protective relaying, basic terminology.
Relays:
Electromagnetic, attracted and induction type relays, thermal relay, gas actuated relay, design considerations of electromagnetic relay.
Unit-II: Relay Application and Characteristics:
Amplitude and phase comparators, over current relays, directional relays, distance relays, differential relay.
Static Relays: Comparison with electromagnetic relay, classification and their description, over current relays, directional relay, distance relays, differential relay.
Unit-III Protection of Transmission Line:
Over current protection, distance protection, pilot wire protection, carrier current protection, protection of bus, auto re-closing,
Unit-IV: Circuit Breaking:
Properties of arc, arc extinction theories, re-striking voltage transient, current chopping, resistance switching, capacitive current interruption, short line interruption, circuit breaker ratings.
Testing Of Circuit Breaker: Classification, testing station and equipments, testing procedure, direct and indirect testing.
Unit-V Apparatus Protection:
Protection of Transformer, generator and motor.
Circuit Breaker: Operating modes, selection of circuit breakers, constructional features and operation of Bulk Oil, Minimum Oil, Air Blast, SF6, Vacuum and d. c. circuit breakers.
Blind Spots of Low Voltage Testing Webinar Presented by Megger BakerTranscat
Find faults where they begin, not where they end.
When the highest reliability is demanded of your motors, high voltage testing is not just an option - it's a necessity. This webinar will focus on the theory and application of electric motor insulation testing techniques.
Importance on switchgear, its teatings commesioning
saving on losses instad of using stat delta starter use of VFDs with same operation but savings in losses
FACULTY OF ENGINEERING & TECHNOLOGY , GURUKULA KANGARI UNIVERSITY ,HARIDWARashwini kumar
THIS PROJECT IS RELATED TO GAS INSULATED SUBSTATION,,IN THIS SUBSTATION SF6 GAS IS USED
ASHWINI KUMAR
ELECTRICAL ENGINEERING(FINAL YEAR)
ashwinikmr555@gmail.com
+919027134556
Power Plant Regenerative feed heating and design aspects of Feed Heaters.This is a ppt for beginners in Power Plant Engineering.Also discusses Heat Transfer and Rankine cycle.
This presentation will discuss how the use and need for voltage transformers has changed over the last twenty years. With the introduction of auto-ranging electric meters, meter technicians need to be prepared, use the appropriate tools and PPE for high capacity circuits (without VT's), as this method has become increasingly popular.
High voltage technology & insulation testingZeeshan Akhtar
About HV Transmission, distribution, Voltage level classification, Insulation testing.
Part 1
What is High Voltage?
Why Needed
Levels of Voltages
Application of High Voltage
Electrical Insulation and Dielectrics
Part 2
Design & Test Issues for High Voltage
Aircraft Electric Power System
Introduction to the importance of HV in electric actuator systems
Basic review of HV design
Discussion of test methods
Summary
Part 3
Voltage Testing & Partial Discharge Measurement For Power Cable Accessories
Introduction
Ac Test After Installation
Acrf Test System
Schematic Diagram Of Test System
Arallel Operation Mode Of Test System
Artial Discharge Methods & Principle.
Iscussion & Conclusion.
THE WORKSHOP:
This practical workshop covers all the essentials of process control and tools to optimise the operation of your plant and process, including the ability to perform effective loop tuning.
Practical process control is aimed at engineers and technicians who wish to have a clear, practical understanding of the essentials of process control and loop tuning, as well as how to optimise the operation of their particular plant or process. These persons would typically be primarily involved in the design, implementation and upgrading of industrial control systems. Mathematical theory has been kept to a minimum with the emphasis throughout on practical applications and useful information.
Inspection, Testing and Commissioning of Electrical Switchboards, Circuit Bre...Living Online
THE WORKSHOP:
Whether you are designing, specifying, installing, testing or commissioning electrical equipment from small to large commercial and industrial installations, you need to have a thorough understanding of switchboards, switchgear, circuit breakers and associated protective relays.
The overall focus of this workshop is on electrical inspection, testing and commissioning and will commence with a detailed examination of switchgear (and circuit breakers). Circuit breakers are critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. Protection relays are then discussed. These are used in power systems to maximise continuity of supply and are found in both small and large power systems from generation, through transmission, distribution and utilisation of power in plant, industrial and commercial equipment.
We cover commissioning and periodic inspection of cables and their various failure modes and how to detect these faults. The often neglected topic of switchboards will be detailed next, followed by the interesting topic of interfacing to the control system (either PLC’s or other control devices).
Case studies and practical sessions are used throughout to illustrate key practical principles.
This workshop covers key elements in a practical and project focused way. Many people assume (wrongly) that inspecting, testing and commissioning is a fairly straightforward process and is simply a rubber stamp confirmation of a so-called outstanding design. Our experience in the field demonstrates quite the opposite; where the litany of problems ranges from design and installation errors to equipment manufacturing defects. It is best that these problems are identified and corrected before the inevitable downtime comes in an operational installation where many thousands of dollars are lost in correcting the faults. The situation today is made more challenging by the heightened safety requirements and interfacing to low powered electronic control and monitoring devices (such as PLC’s) using software that has to also be verified.
Hands on Data Communications, Networking & TCP/IP TroubleshootingLiving Online
THE WORKSHOP:
Data communication is given high priority in today’s industrial environment. This workshop is designed to be hands-on, providing the participants with essential knowledge and helping them to understand and troubleshoot systems.
This is a comprehensive two-day hands-on workshop that covers practical aspects of data communication such as serial communications, Ethernet networking, TCP/IP, Modbus, wireless communications and security.
This workshop is for enthusiastic engineers and technicians who wish to develop and enhance their practical knowledge in the field of data communications and networking. It will help them to understand the concepts behind data transmission, the various protocols involved, and the topologies that govern data exchange among various systems in industry. It will also equip them with the skills and tools to design and/or maintain these systems on an ongoing basis.
Fundamentals of Instrumentation, Process Control, PLCs and SCADA for Plant Op...Living Online
THE WORKSHOP:
This course represents a tremendous opportunity to gain expertise in all the key areas of the fast growing area of industrial automation in two days. Presented by an expert in the area but who is passionate with getting the key chunks of know-how and expertise across to you in a simple understandable manner which you can immediately apply to your job. This is most definitely not a boring lecture style presentation but an intensive learning experience where you will walk away with real skills as a result of the hands-on practical exercises, calculations, case studies and group sessions to ensure an understanding of the concepts and ideas discussed. You will undertake practical sessions at approximately 20 to 30 minute intervals to maximise the absorption rate.
Practical Alarm Management for Engineers and TechniciansLiving Online
The manual focuses on simple and practical information for personnel ranging from operators all the way up to supervisors, engineers and managers.
FOR MORE INFORMATION: http://www.idc-online.com/content/practical-alarm-management-engineers-and-technicians-26?id=8
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
TECHNICAL TRAINING MANUAL GENERAL FAMILIARIZATION COURSEDuvanRamosGarzon1
AIRCRAFT GENERAL
The Single Aisle is the most advanced family aircraft in service today, with fly-by-wire flight controls.
The A318, A319, A320 and A321 are twin-engine subsonic medium range aircraft.
The family offers a choice of engines
Democratizing Fuzzing at Scale by Abhishek Aryaabh.arya
Presented at NUS: Fuzzing and Software Security Summer School 2024
This keynote talks about the democratization of fuzzing at scale, highlighting the collaboration between open source communities, academia, and industry to advance the field of fuzzing. It delves into the history of fuzzing, the development of scalable fuzzing platforms, and the empowerment of community-driven research. The talk will further discuss recent advancements leveraging AI/ML and offer insights into the future evolution of the fuzzing landscape.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Forklift Classes Overview by Intella PartsIntella Parts
Discover the different forklift classes and their specific applications. Learn how to choose the right forklift for your needs to ensure safety, efficiency, and compliance in your operations.
For more technical information, visit our website https://intellaparts.com
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Immunizing Image Classifiers Against Localized Adversary Attacks
Practical Medium and High Voltage Testing of Electrical Equipment for Engineers and Technicians
1. PRACTICAL
MEDIUM & HIGH
VOLTAGE TESTING
OF ELECTRICAL
EQUIPMENT
FOR ENGINEERS & TECHNICIANS
2. 1
Introduction
1.1 Electrical system
The electrical distribution network has become the main nerve center of economic
activities today. When electricity was invented a couple of centuries back, no one could
have imagined the quantum of electricity being generated in the world today; it runs to
millions of mega watts. This had been possible by the simultaneous invention of many
electrical equipment which are used to distribute the generated power to many remote
corners of the world.
The following is a very simple network of an electrical system comprising of many
electrical equipment, shown in single line diagram.
3. Practical HV and MV Testing of Electrical Equipment
2
Figure 1.1
Typical HV/MV electrical network
1.2 HV AND MV equipment
The above diagram includes transformers which are mainly used to transform the voltage
from one value to another. Hence it is obvious that any electrical system intended to serve
many consumers, whether in a plant or a township or a country, primarily consists of
equipment whose voltage ratings will differ from one zone to another. This is mainly
because of the use of transformers, which are the backbones of efficient electrical
distribution at minimum losses.
The use of equipment at different voltage levels has led to the need for demarcation of
type of equipment based on their normal operating voltage. This is termed as Nominal
operating voltage of equipment. The main reason for demarcation is to limit the cost of
equipment to be used at a particular voltage. It is some times very common to find
4. Introduction
3
equipment rated at say 6.6 kV and 13.8 kV being used at 3.3 kV and 11 kV respectively.
But the reasons may be more due to the range manufactured in a country from where the
particular equipment is imported.
The operating voltages are broadly divided to three main categories:
• High Voltage refers to voltages above 69 kV as per ANSI standards. It is also
common practice to refer to this range as Extra High Voltage (EHV) in
Europe and Asian countries.
• Medium Voltage (MV) refers to equipment above 1 kV up to and including
69 kV. In some parts of the world, MV voltage is used for capacity up to 3.3
kV, beyond which the term HV is applied. (That is one reason for the term
EHV)
• Low Voltage (LV) refers to voltages up to 1 kV but generally the operating
voltage seldom is expected to be between 500 to 1000 V under this category.
Low voltage distribution is the most common one ranging from the simple lighting
switch where you are reading this manual to small switch boards and motor control
centers. LV equipment are mainly limited for controlling small power loads whose ratings
may range from fractional to a few hundreds of HP.
The equipment considered in this manual mostly cover those falling in the EHV, HV
and MV category with a brief description covering LV equipment as well. It shall be
remembered that most of the tests which verify the condition of equipment insulation do
need test voltages exceeding 1 kV but at the same time the testing and measurements
invariably derive these high voltages using low voltage equipment.
1.3 Use of HV and MV equipment
Though there is no theoretical boundary or battery limits for the areas using HV and MV
equipment but practical reasons dictate the use of HV and MV equipment based on the
power requirements and applications.
1.3.1 High voltage equipment
HV equipment is extensively used in the following areas.
• Generating stations where the bulk of the generated power is transferred at
voltages above 110 kV up to and including 765 kV; mainly to cut down the
transmission losses and the transmission cost.
• Intermediate substations of utilities involved in power transmission and
distribution, which are mainly used to step down the very high voltages to a
lesser high voltage to enable flexibility in the power distribution covering
switching/changeover applications and for local distribution substations.
• Receiving substations in utilizing industries where the maximum receiving
voltages are generally limited to a maximum of 275 kV with the minimum in
the range of 110 to 132 kV. (Though majority of the industries i.e. almost
90% in terms of numbers, receive power at medium voltage from as low as
3 kV in some parts of the world).
5. Practical HV and MV Testing of Electrical Equipment
4
1.3.2 Medium voltage equipment
The use of MV equipment is mainly applicable in the following areas.
• Industries whose plant demand is limited to around 50 MVA. However the
provision of MV voltage is more governed by the availability of grid lines in
the vicinity. (There are no strict common rules in international standards
regarding the limitation of use of medium voltage with respect to MVA
demand but almost followed strictly due to practical reasons).
• Receiving substations in commercial buildings and residential
townships/apartments, where the incoming voltages are mostly limited to
around 13.8 kV.
• Generating stations. Since the generating voltage is limited to around 33 kV, it
is necessary to use MV equipment matching the generated voltage before
transferring the power through the local grid at High Voltage.
• Induction and synchronous motors of many industries and commercial
complexes with their terminal voltages invariably limited to ratings of around
3 kV to 6.6 kV for less than 5 MW and upto 13.8 kV beyond these ratings.
However motors with voltages in the range of 69 kV are already produced
under special applications and this has been possible with developments in
designs leading to easy availability of insulated cables rated for these higher
voltages.
1.3.3 Common HV and MV equipment
The common HV and MV equipment used in the electrical system are generally the
following:
• Circuit Breakers (HV and MV)
• Air break switches/disconnectors/ isolators (HV and MV)
• Instrument transformers (CTs, PTs, etc, HV and MV)
• Switchgear panels (limited to MV)
• Transformers (HV and MV)
• Lightning arrestors (HV and MV)
• Generators (MV)
• Induction and Synchronous Motors (MV)
• Bus ducts (MV)
• Capacitors (MV)
• Cables (HV and MV)
It is to be noted almost all the above equipment are also available for low voltage use.
This manual will cover electrical testing procedures adopted for a majority of the above
equipment including their main insulating mediums like oil, SF6, etc.
1.4 Need for testing
The continuity of power distribution depends on the reliability of the electrical equipment
in a system. While the reliability of many equipment have increased manifold during the
last century, it is not recommended to connect any finished equipment to a system
directly from the manufacturing place, unless its performance is proven. Earlier
manufacturers had to think of many ways to prove the worthiness and reliability of their
equipment. Nevertheless due to various reasons, manufacturers duplicating proven
6. Introduction
5
equipment also gained entry into the market. This had led to claims and counterclaims by
the sellers, with consumers and end users being confused.
However the concepts have changed and bringing equipment under a common umbrella
to prove their performance have slowly become the practice in every country. Each
country had established committees and organizations to ensure the uniformity and
performance of electrical equipment in an orderly way. This has led to the release of
electrical standards in each country (for all electrical equipment). The major content of
most of these cover the minimum tests that are to be conducted on any equipment in an
environment that may be more severe than normal operating conditions; in terms of
voltage and current levels.
With the sharing of knowledge among intellectuals from different regions and with
globalization leading to the use of electrical equipment from different parts of the world,
a common way to establish the capability of equipment has been accepted. This has lead
to mandatory testing of electrical equipment before being put into use. The tests and the
methods to be followed are covered in all electrical standards.
It can be concluded that testing on electrical equipment is needed
• To prove the performance of an equipment before being put into service
• To ensure that the equipment is assessed on a common basis with respect to
their technical capabilities
• The end user is confident about the capability and performance of the
equipment where it is to be used
• An assurance is established to show that the equipment will not cause any
damage to property and personnel, when the equipment is put into service.
1.5 Purpose of testing
Most electrical equipments are produced by assembling various components made of
different materials. The internal construction of the final equipment like transformers,
circuit breakers, etc are not visible from the outside and it is not possible to visually check
the performance of each and every part under a particular operating condition. Hence it is
necessary to find ways to check the performance of the equipment in its full form without
dismantling it. Accordingly ways and means have been drawn out to check the
performance of the complete equipment in its final form which has become the basis of
all electrical equipment standards. The testing helps in identifying the defects that may be
inherent in particular equipment. Hence it enables the user to take a decision whether to
use or not to use the equipment under known circumstances.
The purpose of electrical testing on major equipment is basically to ensure that the
equipment will function as desired, when it is installed and energized within its specified
voltage and load conditions. This is basically like an insurance premium to be spent
before the equipment is accepted in a particular installation. The other purpose is to
develop a set of base line test results of the equipment that can be compared in future to
identify deterioration and therefore for taking corrective actions.
1.6 Categories of tests
Depending on the area/nature of the tests, they may be categorized as
• Factory tests
• Field/pre-commissioning tests
The factory tests are the major tests that are to be conducted by the manufacturer before
declaring that the equipment suits a particular application.
7. Practical HV and MV Testing of Electrical Equipment
6
These are categorized as:
• Type tests/design tests: These are normally done on identical equipment.
These tests can be destructive in some cases in a sense that the type tested
equipment may not be usable again. Hence it is not expected that the
equipment under use is type tested but its design should have been proven by
conducting tests on similarly designed equipment. All type tests are not
destructive. Some times when multiple quantities of similar equipment are
ordered, it is acceptable that one unit alone passes these tests.
• Routine tests: These are the necessary basic tests that are to be conducted by a
manufacturer even if a customer does not specifically indicate this
requirement. Any equipment which had failed in any of the routine tests is
generally NOT to be used for the desired application. However under
exceptional cases some routine tests may be repeated after making minor
alterations to internal construction. It may be noted that all electrical
equipment in service, should pass the routine tests.
• Acceptance tests: Some of the tests are to be conducted in case the operating
conditions demand the same. These tests may not be applicable for all
operating conditions and are mostly guided by the application of the particular
equipment.
• Sample tests: When tens and hundreds of identical equipment are ordered, it is
not necessary to conduct the same set of tests on each and every unit.
Standards define the quantities to be considered for sample testing and the
items are randomly tested to prove their capacity. The quantities to be selected
are defined by a table or by some formula and samples are chosen
accordingly.
• Special tests/other tests: These are defined by standards for some specific
equipment at some specific ratings/capacities. These are invariably defined for
tests like partial discharge tests, impulse withstand voltage tests, etc which are
normally applicable for operating voltages above specified ranges like 132 kV
or 220 kV.
• Field tests: As the name implies these are tests that are conducted on
equipment in the field of service before being put into service. Invariably
most of the pre-commissioning tests are almost same as routine tests (like
megger tests, insulation tests, etc).
• Maintenance tests: These are tests conducted at regular intervals as part of
maintenance checks to maintain performance. Typical tests are conducted on
items like relays, etc which control the HV equipment and on oil which is the
insulating medium in transformers.
1.7 Variations to test voltages and results
It is not practically possible to test the electrical equipment in ambient conditions at
which they are expected to be in service. The major conditions that can affect
performance and its acceptance by the end user are
• Altitude above sea levels
• Maximum and minimum ambient temperatures
• Tolerances on test results
8. Introduction
7
Hence it is customary to define the performance requirements at pre-defined altitude
and temperature and also to correct the test results to some basic temperature conditions;
so that the equipment performance can be evaluated in a true sense.
1.7.1 Altitudes above sea level
The major requirement for any electrical equipment is that it shall be able to withstand
some minimum voltage across its terminals and also across each terminal to earth, since
the equipment is expected to carry its rated voltage throughout its life. Hence almost all
HV and MV equipment shall be tested to prove its capacity to withstand voltage
conditions. These are generally called Dielectric tests. Most electrical equipment has its
terminals separated by air. This means that air is the insulating medium, though internally
their parts may be filled with some other insulating medium like oil. It is well known that
the breakdown voltages across two terminals separated by air vary with the ambient
temperature due to the presence of moisture at higher altitude conditions. Hence it is
usual to define test voltages at some minimum altitude conditions. The standards
normally consider an altitude of 1000 meters above sea level, to define the test voltages to
be withstood by equipment. Correction factors shall be applied for altitudes above this
value, which means the equipment, shall be able to withstand higher operating voltages at
higher altitudes.
1.7.2 Temperature conditions
Similarly the operating temperature can vary the factors like impedance, temperature rise,
etc. The variation of temperatures could be critical to assess the losses of major electrical
equipment (like power transformers, motors, generators, etc). It is usual to correct the
results to a common temperature, which is 75ºC for electrical equipment. Hence the
testing engineer shall ensure that the test results are properly corrected to take care of the
altitude and temperature conditions.
The operating temperatures can affect the ratings of some main equipment like
transformers and generators because their current ratings are dependent on the windings
that carry the currents. Hence it is necessary to define the ratings based on the expected
operating temperatures.
1.7.3 Tolerances
The other major condition on which test results are dependant is the applicable tolerance
level. It is necessary that there cannot be any tolerance on the test voltages after applying
the above correction factors. This means that any equipment failing at 99.9 kV with its
defined test voltage of 100 kV can not be considered to have passed this test. At the same
time the losses and impedance values which are normally measured during tests, cannot
meet the guaranteed figures exactly. Hence it is usual to define tolerances on test result
values for such guaranteed figures and the equipment is accepted to meet the testing
requirements if the results fall within the defined tolerance value.
The following sections also include the conditions and tolerances that are normally
applicable for various HV/MV equipment test values and their respective results.