This document discusses the P-delta effect on tall reinforced concrete buildings with and without shear walls. P-delta is a second-order geometric nonlinearity effect that occurs when axial loads cause additional deflection in structures. The study analyzes a 20-story RC building model in ETABS to compare displacements, bending moments, and other parameters with and without considering P-delta effects under seismic and wind loads. Results show that P-delta effects decrease story displacements when shear walls are used and bending moments increase slightly in columns and shear walls after accounting for P-delta.
While Designing a High rise Load & Structural Analysis is major factor to consider. Here we analyzed some data and try to describe briefly. We hope that it will help you lot :) Done by Neeti Lamic, Bayezid, Sykot Hasan
P delta effect in reinforced concrete structures of rigid jointYousuf Dinar
ABSTRACT: Popularity of High-Rise structures of rigid joint frame system are increasing day by day to accommodate growing people in metropolitan city and to construct the structures without any special structural component. However combination of rigid frame with RC structure get 30 storey as maximum storey and prone to collapse under severe displacement, axial force and moment, if the P-Delta effects does not included in analysis and design phase. Due to complexity and low knowledge of P-Delta analyses designers, engineers and architectures are prone to perform Linear Static analysis which may eventually become a cause of catastrophic collapse of the high-rise. 12 cases and 2 different analysis are performed to give a light on the P-Delta effect in RC Structures of Rigid Joint which will aware and suggest concerning person to understand, make experience and perform P-Delta analysis of the high-rise for safety using numerical modelling which may accelerate the process and reduce the complexities.
While Designing a High rise Load & Structural Analysis is major factor to consider. Here we analyzed some data and try to describe briefly. We hope that it will help you lot :) Done by Neeti Lamic, Bayezid, Sykot Hasan
P delta effect in reinforced concrete structures of rigid jointYousuf Dinar
ABSTRACT: Popularity of High-Rise structures of rigid joint frame system are increasing day by day to accommodate growing people in metropolitan city and to construct the structures without any special structural component. However combination of rigid frame with RC structure get 30 storey as maximum storey and prone to collapse under severe displacement, axial force and moment, if the P-Delta effects does not included in analysis and design phase. Due to complexity and low knowledge of P-Delta analyses designers, engineers and architectures are prone to perform Linear Static analysis which may eventually become a cause of catastrophic collapse of the high-rise. 12 cases and 2 different analysis are performed to give a light on the P-Delta effect in RC Structures of Rigid Joint which will aware and suggest concerning person to understand, make experience and perform P-Delta analysis of the high-rise for safety using numerical modelling which may accelerate the process and reduce the complexities.
Bracing elements in structural system plays a vital role in the seismic behaviour of high rise buildings during earthquake. Many of the structural failures in buildings during strong earthquake shaking have indicated that sustainable strength and stable energy dissipation capability are most desirable to maintain inter story drifts and overall structural displacements within tolerable levels. So earthquake action brings a greater concern in the structural design of buildings which is situated in earthquake prone areas. Steel bracing are the common type which mainly used to resist the lateral loads acting during a seismic activity. Conventional types of lateral load resisting systems are concentrically-braced frames (CBFs) and eccentrically braced frames (EBF). Buckling Restrained Braces (BRB) are recent developed structural system which has a stable energy dissipation property. Main advantage of BRB is its ability to yield both in tension and compression without buckling, thus obtaining a stable hysteresis loop. The BRB brace placed in a concentric frame is termed as BRBF system.
Special shear walls + ordinary shear walls ACI - 318 - جدران القص الخاصة - P...Dr.Youssef Hammida
Specifications of Special
shear walls
• 1- to form a plastic hinge and wall work in the plastic area
distracting section of the quake, where increasing energy transfer and nonlinear distortions
With firmness despite rising resistance section loads base shear forces
Detailed plastically shaped at the bottom of the wall up the foundation base point
Where the forces of bending moment and shear baseband is greatest
• 2 - have a long high hinge plastically area along the height of the wall
And almost equal to the rise in the wall / 6, H / 6 or along the plan length L
• 3 - the region where the plastic hinge cracked consider (cracked section) and the reduction of inertia (Ig) = (0.35 - 0.5) according to the local code
But after the hinge ductile shear wall treats ordinary wall
area (un cracked section) = (0.7 - 0.8)
• 4 - neglecting the resistance of concrete to resist shear forces
and reinforcing longitudinal and horizontal
In the area and the plastic hinge along only
Bracing elements in structural system plays a vital role in the seismic behaviour of high rise buildings during earthquake. Many of the structural failures in buildings during strong earthquake shaking have indicated that sustainable strength and stable energy dissipation capability are most desirable to maintain inter story drifts and overall structural displacements within tolerable levels. So earthquake action brings a greater concern in the structural design of buildings which is situated in earthquake prone areas. Steel bracing are the common type which mainly used to resist the lateral loads acting during a seismic activity. Conventional types of lateral load resisting systems are concentrically-braced frames (CBFs) and eccentrically braced frames (EBF). Buckling Restrained Braces (BRB) are recent developed structural system which has a stable energy dissipation property. Main advantage of BRB is its ability to yield both in tension and compression without buckling, thus obtaining a stable hysteresis loop. The BRB brace placed in a concentric frame is termed as BRBF system.
Special shear walls + ordinary shear walls ACI - 318 - جدران القص الخاصة - P...Dr.Youssef Hammida
Specifications of Special
shear walls
• 1- to form a plastic hinge and wall work in the plastic area
distracting section of the quake, where increasing energy transfer and nonlinear distortions
With firmness despite rising resistance section loads base shear forces
Detailed plastically shaped at the bottom of the wall up the foundation base point
Where the forces of bending moment and shear baseband is greatest
• 2 - have a long high hinge plastically area along the height of the wall
And almost equal to the rise in the wall / 6, H / 6 or along the plan length L
• 3 - the region where the plastic hinge cracked consider (cracked section) and the reduction of inertia (Ig) = (0.35 - 0.5) according to the local code
But after the hinge ductile shear wall treats ordinary wall
area (un cracked section) = (0.7 - 0.8)
• 4 - neglecting the resistance of concrete to resist shear forces
and reinforcing longitudinal and horizontal
In the area and the plastic hinge along only
Performance of High-Rise Steel Building With and Without BracingsIJERA Editor
A comparative study on performance of high-rise steel building with and without bracings, carried
out on a residential building by considering the gravity loads and lateral loads in the form of Earth quake loads
and Wind loads incorporating the Bracings to reduce lateral loads on structural elements. In this study, a 20
storey steel frame structure has been selected to be idealized as multi storey steel building model. The model is
analyzed by using STAAD.Pro 2008 structural analysis software with the consideration of wind and earthquake
loads. At the same time the influence of X-bracing pattern has been investigated.The building proposed in
designed by Limit State Method according to steel code IS: 800-2007, the Wind load analysis according to IS:
875-(part-3)1987 and seismic/Earth quake loads according to IS: 1893 (Part-1)-2002. In this study the node
displacements of buildings having with and without bracings of wind and earthquake effect of Zone II and
Zone V, and the axial force of the members of the buildings having with and without bracings of wind and
earthquake effect of Zone II and Zone V.
Variation of deflection of steel high rise structure due to p- delta effect c...Yousuf Dinar
Abstract—This paper evaluates deflection of the steel high rise structure due to the P-Delta effect considering the global slenderness of the whole structure. For easy and quick design only Linear Static analysis is performed and secondary loading effect is neglected in several underdeveloped and developing countries of South Asia. Using STAADPro v8i, 40 different model is simulated to observe the severity of the P-Delta phenomenon against standard Linear Static method. 4 different storey were combined with 5 varying span in both direction for varying the slenderness of the structure. During analysis lateral load imposed with UBC94 to perform the seismic events in two directions in the seismic moderate risk zone of Bangladesh using Bangladesh National Building Code (BNBC) corresponding coefficients however wind load is omitted to observe the seismic event effect in Steel high-rise structure solely assuming outcome decision would be same if the simulation would done for wind load also. This analysis reveals how crucial side of the structure generates different deflections with changing slenderness. Test results were evaluated by storey deflection (in mm) and percentage of variation of deflection was performed by comparing P-Delta outputs with Linear Static Method outputs.
Influence of Combine Vertical Irregularities in the Response of Earthquake Re...IOSRJMCE
This study investigates the effect of frame set-back with vertical irregularity in height on accuracy of Pushover Analysis for predicting target displacement, story drifts, base shear and performance point. The behavior of high rise building during strong earthquake motion depends on the distribution of mass, stiffness and strength in both horizontal and vertical planes of the buildings. The Indian IS code 1893:2002(Part 1) has pointed out of different structures irregularities like plan irregularity and vertical irregularity. In this study the seismic performance of G+ 16 storey having combine effect of vertical irregularity with R.C building are examined using Non Linear Static Analysis (Pushover Analysis). The Base shear, lateral displacement, storey drift and performance points are the response parameters use to quantify the performance of the structure. These irregularities are responsible for structural collapse of buildings under the action of dynamic loads. Five different types of building geometry are taken one regular and four irregular frames. The all buildings are modeled and analyzed in software SAP 2000. It was found that irregularity in elevation of the building reduce the performance level of structure.
International Journal of Engineering and Science Invention (IJESI) is an international journal intended for professionals and researchers in all fields of computer science and electronics. IJESI publishes research articles and reviews within the whole field Engineering Science and Technology, new teaching methods, assessment, validation and the impact of new technologies and it will continue to provide information on the latest trends and developments in this ever-expanding subject. The publications of papers are selected through double peer reviewed to ensure originality, relevance, and readability. The articles published in our journal can be accessed online.
HEAP SORT ILLUSTRATED WITH HEAPIFY, BUILD HEAP FOR DYNAMIC ARRAYS.
Heap sort is a comparison-based sorting technique based on Binary Heap data structure. It is similar to the selection sort where we first find the minimum element and place the minimum element at the beginning. Repeat the same process for the remaining elements.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Using recycled concrete aggregates (RCA) for pavements is crucial to achieving sustainability. Implementing RCA for new pavement can minimize carbon footprint, conserve natural resources, reduce harmful emissions, and lower life cycle costs. Compared to natural aggregate (NA), RCA pavement has fewer comprehensive studies and sustainability assessments.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
NUMERICAL SIMULATIONS OF HEAT AND MASS TRANSFER IN CONDENSING HEAT EXCHANGERS...ssuser7dcef0
Power plants release a large amount of water vapor into the
atmosphere through the stack. The flue gas can be a potential
source for obtaining much needed cooling water for a power
plant. If a power plant could recover and reuse a portion of this
moisture, it could reduce its total cooling water intake
requirement. One of the most practical way to recover water
from flue gas is to use a condensing heat exchanger. The power
plant could also recover latent heat due to condensation as well
as sensible heat due to lowering the flue gas exit temperature.
Additionally, harmful acids released from the stack can be
reduced in a condensing heat exchanger by acid condensation. reduced in a condensing heat exchanger by acid condensation.
Condensation of vapors in flue gas is a complicated
phenomenon since heat and mass transfer of water vapor and
various acids simultaneously occur in the presence of noncondensable
gases such as nitrogen and oxygen. Design of a
condenser depends on the knowledge and understanding of the
heat and mass transfer processes. A computer program for
numerical simulations of water (H2O) and sulfuric acid (H2SO4)
condensation in a flue gas condensing heat exchanger was
developed using MATLAB. Governing equations based on
mass and energy balances for the system were derived to
predict variables such as flue gas exit temperature, cooling
water outlet temperature, mole fraction and condensation rates
of water and sulfuric acid vapors. The equations were solved
using an iterative solution technique with calculations of heat
and mass transfer coefficients and physical properties.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers