In electrical engineering, a synchronous condenser (sometimes synchronous capacitor or synchronous compensator) is a device identical to a synchronous motor, whose shaft is not connected to anything but spins freely.
As the AIS (Air-Insulated Substation) is having more limitations, More and more people are going for the Gas-Insulated Substation which is environment friendly as well.
In these presentation, We discussed about theoritical and technological advancement and advantages related to GIS as compared to other substations.
We discussed different parts of the GIS as well as their operations and advantages.
By going through this presentation, you will have idea regarding comparative advantages and disadvantages of both substations.
In electrical engineering, a synchronous condenser (sometimes synchronous capacitor or synchronous compensator) is a device identical to a synchronous motor, whose shaft is not connected to anything but spins freely.
As the AIS (Air-Insulated Substation) is having more limitations, More and more people are going for the Gas-Insulated Substation which is environment friendly as well.
In these presentation, We discussed about theoritical and technological advancement and advantages related to GIS as compared to other substations.
We discussed different parts of the GIS as well as their operations and advantages.
By going through this presentation, you will have idea regarding comparative advantages and disadvantages of both substations.
Generation of High D.C. Voltage (HVDC generation)RP6997
Generation of high dc voltage using different methods like half wave and full wave rectifier, voltage doubler circuits, voltage multiplier circuits, cockcroft-walton circuits and van de graaff generators.
Paschen's law Is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. It is named after Friedrich Paschen who discovered it empirically in 1889. Paschen studied the breakdown voltage of various gases between parallel metal plates as the gas pressure and gap distance was varied:
About Transmission Line.
Transmission Lines
Classification Of Transmission Lines
Overhead Power Line
Advantages Of Overhead Transmission Lines
Disadvantages Of Overhead Transmission Lines
Nominal “T” Method
Nominal “Pi” Model of a Medium Transmission Line
Underground Transmission Lines
Classification Of Underground Cables
Advantages Of Underground Cables
Disadvantages Of Underground Cables
In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. The theory and application of these protective devices is an important part of the education of a power engineer who specializes in power system protection.
This presentation provides information about different types of protective relaying system.
Loadability of line is defined as the extent of load which can flow through the line without exceeding the limitations. Line Loadability is expressed in percentage of Surge Impedance Loading of line. The limiting factor for line loading are: thermal limit, voltage drop limit and steady state stability.
Generation of High D.C. Voltage (HVDC generation)RP6997
Generation of high dc voltage using different methods like half wave and full wave rectifier, voltage doubler circuits, voltage multiplier circuits, cockcroft-walton circuits and van de graaff generators.
Paschen's law Is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. It is named after Friedrich Paschen who discovered it empirically in 1889. Paschen studied the breakdown voltage of various gases between parallel metal plates as the gas pressure and gap distance was varied:
About Transmission Line.
Transmission Lines
Classification Of Transmission Lines
Overhead Power Line
Advantages Of Overhead Transmission Lines
Disadvantages Of Overhead Transmission Lines
Nominal “T” Method
Nominal “Pi” Model of a Medium Transmission Line
Underground Transmission Lines
Classification Of Underground Cables
Advantages Of Underground Cables
Disadvantages Of Underground Cables
In electrical engineering, a protective relay is a relay device designed to trip a circuit breaker when a fault is detected. The theory and application of these protective devices is an important part of the education of a power engineer who specializes in power system protection.
This presentation provides information about different types of protective relaying system.
Loadability of line is defined as the extent of load which can flow through the line without exceeding the limitations. Line Loadability is expressed in percentage of Surge Impedance Loading of line. The limiting factor for line loading are: thermal limit, voltage drop limit and steady state stability.
High-frequency welding is included in a group of resistance welding process variations that use high-frequency welding current (1kHz to 800kHz) to concentrate the welding heat at the desired location.
The heat produces the coalescence of metals, and an upsetting force usually is applied to produce a forged weld.
High-frequency resistance welding is an automated process and is not adaptable to manual welding.
High-frequency resistance welding was developed during the late 1940s and early 1950s to fill the need for high-integrity butt joints and seam welds in pipe and tubing.
But today the process is also used in the manufacture of products such as spiral-fin boiler tubes, closed roll form shapes, and welded structural beams.
A wide range of commonly used metals can be welded, including low-carbon and alloy steels, ferritic and austenitic stainless steels, and many aluminum, copper, titanium, and nickel alloys.
HFW is based on two main electrical phenomena
Skin effect
Proximity effect
This slide is for mechanical engineering student. this is basically describes about the arc welding and its types with processes and also its advantages and disadvantages..... Remember us in your Prayers Folks.
A transducer is a device which transforms a non-electricalphysical quantity (i.e. temperature, sound or light) into anelectrical signal (i.e. voltage, current, capacity…)
In a generating station the generator and transformer are the most expensive equipments and hence it is desirable to employ protective system to isolate the faulty equipment as quickly as possible to keep the healthy section in normal operation and to ensure uninterruptable power supply.
Design of Magnetic Circuit for Synchronous MachineAbhishek Choksi
Mmf required to drive flux in the magnetic circuit of a synchronous machine can be calculated as by the governing terms:-
Mmf for air gap
Mmf for armature teeth
Mmf for core
Mmf for poles
Mmf for yoke
Total field Mmf at no load
Total field Mmf at full load
Load flow studies or Power flow studies is the analysis of a power system in normal steady state condition.
Load flow studies basically comprises of the determination of
Voltage
Current
Active Power
Reactive Power
Pulse Width Modulation, or PWM, is a technique for getting analog results with digital means.
Digital control is used to create a square wave, a signal switched between on and off.
It is that branch of welding in which Electric current is used to produce the large heat required for joining together into firm two pieces of metals.
Electrical welding process fall into two main categories
RESISTANCE WELDING.
ARC WELDING.
DC motor and open loop speed control.
Closed loop speed control of DC drives.
Closed loop speed control with inner loop current control
Closed loop field control
Closed loop armature control.
Synthesis of unsymmetrical phasors from their symmetrical componentsAbhishek Choksi
Power systems are large and complex three phase system
In normal operating conditions , electrical power system operate in balanced condition.
But sometimes certain situation occurs like fault or short circuit which make the system to be unstable.
Single phase equivalent system method of analysis cannot be applied to such system.
In early days, there was a little demand for electrical energy so that small power stations were built to supply lighting and heating loads. However, the widespread use of electrical energy by modern civilisation has necessitated to produce bulk electrical energy economically and efficiently.
The increased demand of electrical energy can be met by building big power stations at favourable places where fuel (coal or gas) or water energy is available in abundance.
The armature winding is the main current-carrying winding in which the electromotive force or counter-emf of rotation is induced.
The current in the armature winding is known as the armature current.
The location of the winding depends upon the type of machine.
The armature windings of dc motors are located on the rotor, since they must operate in union with the commutator.
In DC rotating machines other than brushless DC machines, it is usually rotating.
The microprocessor is the core of computer systems.
Nowadays many communication, digital entertainment, portable devices, are controlled by them.
A designer should know what types of components he needs, ways to reduce production costs and product reliable.
Principle of regenerative braking and chopper configurationAbhishek Choksi
A Regenerative Brake, is an energy recovery mechanism which slows a vehicle or object down by converting its kinetic energy into another form, which can be either used immediately or stored until needed.
Regenerative braking takes place whenever the speed of the motor exceeds the synchronous speed.
This braking method is called regenerative baking because here the motor works as generator and supply itself is given power from the load, i.e. motors.
Root locus is a graphical representation of the closed-loop poles as a system parameter is varied.
It can be used to describe qualitatively the performance of a system as various parameters are changed.
It gives graphic representation of a system’s transient response and also stability.
We can see the range of stability, instability, and the conditions that cause a system to break into oscillation.
Web application attack and audit framework (w3af)Abhishek Choksi
w3af (web application attack and audit framework) is an open-source web application security scanner. The project provides a vulnerability scanner and exploitation tool for Web applications. It provides information about security vulnerabilities and aids in penetration testing efforts. Users have the choice between a graphic user interface and a command-line interface.
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
1. 6th
Sem
Electrical Engineering Department
Batch – B1 (2014 Batch)
Abhishek Choksi
(140120109005)
Design of DC Machines & Transformer (2160912)
ALA Presentation
On
“ Design of LV Winding ”
Prepared By: Guided By:
Prof. Jaimini Gohel
Gandhinagar Institute Of Technology
2. L.V. Winding
• A transformer is a static device.
• The primary and secondary windings of oil filled transformers are
made with aluminium or electrolytic copper.
3. • The main reason behind the LV winding placed nearer to core is the
heat which is proportional to the copper losses occurring in the wires
or winding.
• This heat produced is larger in High Voltage winding than in Low
Voltage winding so for the heat to travel outside the transformer and
to avoid the damage to the transformer the high voltage winding is
placed outside the low voltage winding so that more heat flows outside
the transformer easily.
• If HV winding is placed inside LV winding then heat produced the
Core and LV winding will burn.
7. • The choice of current density depends on the allowable temperature
rise, copper loss and method of cooling.
• After finding the cross section area of LV conductor , the dimension of
conductor are selected as per IS table of copper conductors.
8. Reference
• Wikipedia - https://en.wikipedia.org/wiki/Transformer
• [V.K. Mehta] - electrical machine design
• AK sawhney - electrical machine design
• Aditya-design-of-transformers
• SPX TRANSFORMER SOLUTIONS, INC.
• ABB - http://www.abb.com/transformers
• Minnesota Power Systems Conference November 3 5, 2009 Earl‐
Brown Heritage Center University of Minnesota