The document outlines 7 steps for obtaining necessary licenses and approvals for establishing a radiation installation using medical diagnostic x-ray equipment in India:
1) Obtain site approval from AERB for the layout of the diagnostic x-ray room.
2) Request the equipment manufacturer to conduct quality assurance tests after installation, submitting the results to AERB.
3) Apply to AERB for registration of diagnostic x-ray units or licensing of CT/cathlab units after installation is complete.
4) Ensure only qualified radiologists and technicians operate the equipment in accordance with safety guidelines.
5) Obtain necessary dosimetry badges and have a qualified Radiation Safety Officer.
radiation regulatory bodies. ( international + indian )akshayonslideshar
Radiation is harmful . right ? but who is looking after that it is being used in correct manner in hospitals .I have tried to write about some international and indian regulatory bodies.
Quality Assurance Programme in Computed TomographyRamzee Small
Introduction to Computed Tomography
Basic description of the components of a CT System
Introduction to Quality Assurance
Quality Assurance and Quality Control Tests in Computed Tomography base on frequency
Objective of QA/QC Test
This free eBook was written to help Radiologic Technologists improve their image quality and understand some of the latest tools and techniques available with Computed and Digital Radiography equipment.
radiation regulatory bodies. ( international + indian )akshayonslideshar
Radiation is harmful . right ? but who is looking after that it is being used in correct manner in hospitals .I have tried to write about some international and indian regulatory bodies.
Quality Assurance Programme in Computed TomographyRamzee Small
Introduction to Computed Tomography
Basic description of the components of a CT System
Introduction to Quality Assurance
Quality Assurance and Quality Control Tests in Computed Tomography base on frequency
Objective of QA/QC Test
This free eBook was written to help Radiologic Technologists improve their image quality and understand some of the latest tools and techniques available with Computed and Digital Radiography equipment.
this slide sharer contents are basic principle of CT fluoroscopy , software and hardware parts of equipment and image aqua cation and radiation dose comparison and videos related to equipment .
this slide sharer contents are basic principle of CT fluoroscopy , software and hardware parts of equipment and image aqua cation and radiation dose comparison and videos related to equipment .
AERB registration for a dental RVG x-ray machine.pdfJagriti Agarwal
Obtaining AERB registration ensures that the equipment is being used safely and that radiation exposure is minimized for patients and dental staff. The AERB has set specific safety standards for the use of ionizing radiation in medical and dental imaging, and obtaining registration ensure that these standards are being followed.
Presentation on what it takes to get a clinical study off the ground in the UK along with some info on the impact of directive 2007/47/EC will have on clinical data requirements
This standard provides guidance on the use of infrared thermography for the inspection of low rise, three stories or less, wood or steel frame, residential and light commercial buildings.
싸이퍼랩 RS30은 안드로이드 4.4를 지원하는 안드로이드 PDA로 1.3GHz Cortex Quad Core CPU를 채택한 기업용 모바일 컴퓨터로서 기존의 스마트폰 사용자 환경에 친숙한 유저 인터페이스를 제공하고, 기업의 업무환경에 적합하도록 견고성 및 NFC, 바코드스캔, 무선통신등 다양한 기능을 제공합니다.
유통 및 물류 산업분야 사용에 적합하게 설계되었으며, TCO(총소유비용)를 낮추어주는 경제적인 솔루션입니다.
최신 최고 사양
최신 CPU(쿼드코어 1.3Ghz), 높은 메모리용량(8Gb Flash/1Gb RAM) 및 견고한 디스플레이 (4.4인치 고릴라 글래스 3)를 채택한 최신 사양의 안드로이드 디바이스입니다.
스마트폰 사용자에 익숙한 환경
기존 스마트폰과 유사한 UI제공 및 안드로이드(버전4.4)에서 운용되는 모든 어플리케이션을 수정 없이 사용가능합니다.
기업용 환경에 적합한 견고성 제공
일반 스마트폰에 비해 IP54 방수방진 및 1.5m 낙하 충격에도 견딜수 있는 견고성 제공으로 유통, 물류, 창고등의 업무에 적합합니다.
다양한 통신기능
기업 업무에 필요한 무선랜(802.11b/g/n), 3G 통신(HSDPA), 블루투스등을 지원합니다.
다양한 데이타 취득 기능
다양한 바코드 리더(1D CCD, 1D Laser, 2D Imager) 및 NFC기능을 제공하여 다양한 종류의 바코드 인식 및 NFC를 활용한 RFID 어플리케이션을 구현할수 있습니다.
AppLock 기능
RS30 화면의 복잡한 메뉴를 사용자가 필요로하는 메뉴만 화면에 표시가능하여 기기의 화면을 단순하게 유지하여 우연한 사용자 실수를 사전에 방지합니다.
다양한 기기 관리툴 제공
다수의 기기를 제어 및 관리할수 있는 소프트웨어(SOTI) 및 어플리케이션 개발을 지원하는 툴(KALIPSO Mobile Application Generator)을 제공하여 사용자 효율성 및 관리자의 업무 용이성을 높여줍니다.
4.7인치 민감한 터치 패털
0.2mm 두께의 라텍스 장갑 사용가능
PLATFORM, PROCESSOR & MEMORY
Operating System & CPU
OS Version : Android 4.4.2
CPU : Cortex 1.3 GHz Quad-Core Processor
Memory
ROM : 8GB eMMC
RAM : 1GB LPDDR2 RAM
Expansion Slot :
One microSDHC card slot (up to 32GB)
SDXC supported
COMMUNICATION & DATA CAPTURE
Communication
USB Client : USB 2.0 OTG
WPAN : Bluetooth Class II, v4.0 and v2.1+EDR
WLAN : IEEE 802.11b/g/n networking
WWAN :
Built-in module for Quadband HSPA+/GSM
GSM/GPRS/EDGE/WCDMA/UMTS/HSDPA/HSUPA/HSPA+
Frequency band:
GSM/GPRS/EDGE: 850/900/1800/1900
WCDMA/UMTS/HSDPA/HSUPA: 850/900/1900/2100
HSPA+: 14.4 Mbps/5.76 Mbps
Built-in GPS with AGPS support, ephemeris downloadable
Data & Image Capture
Digital Camera : 8 Mega pixels with user-controllable flash
Barcode Reader : Ordering options include Linear Imager (SM1), 1D Laser (SE955), 2D Imager(SE4500)
HF RFID Reader :
ISO14443A/B (Mifare), ISO15693 (Felica)
Supports NFC (Peer-to-peer, Card reader, Card emulation)
ELECTRICAL CHARACTERISTICS
Batteries
Main Battery Pack :
Rechargeable Li-ion battery: 3.7V, 2500 mAh
Charging time: 4 hours
Backup Battery :
Rechargeable Li-ion battery: 3.7V, 70 mAh
Data retention for 30 minutes
Charging time: 4 hours
Power Adaptor
Power Supply Cord with :
Input AC 100~240 V, 50/60 Hz
Universal Power Adaptor :
Output DC 5V, 2A
Working Time
Supports working time for up to 8-10 hours.
PROGRAMMING SUPPORT
Development Environment & Tools
Integrated Environment : Development Visual Studio 2008, Visual Studio 2005
Software Development Kit :
Microsoft SDK
System API (DLL) for system configuration
Reader API (DLL) for reader configuration
Software & Utilities
CipherLab Software Package : Reader Configuration
Third-party Software : Kalipso
ACCESSORIES
Accessory Options :
Hardshell
Charging Cradle
>하이온아이티
주소 : 서울 금천구 가산디지털2로 165, 1304호 (백상스타타워2차)
대표번호 : 02-2038-0018 / 이메일 : hion@hionit.com
홈페이지 : http://hionsmart.com
Welcome to TechSoup New Member Orientation and Q&A (May 2024).pdfTechSoup
In this webinar you will learn how your organization can access TechSoup's wide variety of product discount and donation programs. From hardware to software, we'll give you a tour of the tools available to help your nonprofit with productivity, collaboration, financial management, donor tracking, security, and more.
Macroeconomics- Movie Location
This will be used as part of your Personal Professional Portfolio once graded.
Objective:
Prepare a presentation or a paper using research, basic comparative analysis, data organization and application of economic information. You will make an informed assessment of an economic climate outside of the United States to accomplish an entertainment industry objective.
Palestine last event orientationfvgnh .pptxRaedMohamed3
An EFL lesson about the current events in Palestine. It is intended to be for intermediate students who wish to increase their listening skills through a short lesson in power point.
Synthetic Fiber Construction in lab .pptxPavel ( NSTU)
Synthetic fiber production is a fascinating and complex field that blends chemistry, engineering, and environmental science. By understanding these aspects, students can gain a comprehensive view of synthetic fiber production, its impact on society and the environment, and the potential for future innovations. Synthetic fibers play a crucial role in modern society, impacting various aspects of daily life, industry, and the environment. ynthetic fibers are integral to modern life, offering a range of benefits from cost-effectiveness and versatility to innovative applications and performance characteristics. While they pose environmental challenges, ongoing research and development aim to create more sustainable and eco-friendly alternatives. Understanding the importance of synthetic fibers helps in appreciating their role in the economy, industry, and daily life, while also emphasizing the need for sustainable practices and innovation.
Honest Reviews of Tim Han LMA Course Program.pptxtimhan337
Personal development courses are widely available today, with each one promising life-changing outcomes. Tim Han’s Life Mastery Achievers (LMA) Course has drawn a lot of interest. In addition to offering my frank assessment of Success Insider’s LMA Course, this piece examines the course’s effects via a variety of Tim Han LMA course reviews and Success Insider comments.
Unit 8 - Information and Communication Technology (Paper I).pdfThiyagu K
This slides describes the basic concepts of ICT, basics of Email, Emerging Technology and Digital Initiatives in Education. This presentations aligns with the UGC Paper I syllabus.
How to Make a Field invisible in Odoo 17Celine George
It is possible to hide or invisible some fields in odoo. Commonly using “invisible” attribute in the field definition to invisible the fields. This slide will show how to make a field invisible in odoo 17.
Instructions for Submissions thorugh G- Classroom.pptxJheel Barad
This presentation provides a briefing on how to upload submissions and documents in Google Classroom. It was prepared as part of an orientation for new Sainik School in-service teacher trainees. As a training officer, my goal is to ensure that you are comfortable and proficient with this essential tool for managing assignments and fostering student engagement.
Instructions for Submissions thorugh G- Classroom.pptx
Aerb guidelines for Room installation
1.
2. As per Atomic Energy (Radiation Protection)
Rules 2004 Section (3) a License / Registration
is necessary for establishing a radiation
installation.
This process involves 3 steps.
(i) Site Approval by AERB
(ii) Quality Assurance Test by
manufacturer/supplier under intimation to DRS
(iii) License/Registration by AERB .
3. Guideline 1
Submit completely filled and duly signed “Application
for Site Approval of X-Ray Installation Layout” along
with layout plan of the diagnostic x-ray room, drawn
to scale 1:50 showing details as described in the
application form, in original with two copies for
approval to the Director, Directorate of Radiation
Safety,AERB , Niyamak Bhavan, Anusaktinagar ,
Mumbai-400094.
4.
5. Separate form should be submitted for each
medical diagnostic x-ray unit installation. Mobile
units do not require plan approval (mobile units
should not be used in a room with table) but
need Registration Certificate.
Enclose fees in the form of Demand Draft drawn
in favor of the Director of Radiation Safety
payable at AERB, at the rates prescribed by the
Government.
6. Guideline 2
The room housing an x-ray unit shall not be less
than 18m2 for general-purpose radiography and
conventional fluoroscopy equipment and no single
dimension of the x-ray room shall be less than 4.0m.
The room housing the gantry of the computed
tomography (CT Scan) unit shall not be less than 25
m 2 and no single dimension of the gantry of CT
Scan room shall be less than 4m.
7.
8. The room housing an orthopan tomography
(OPG) units shall not be less that 15 m2 and no
single dimension of the OPG room shall be less
than 3.5m.
The room housing a mammography x-ray unit
shall not be less than 10 m2 and no single
dimension of x-ray room shall be less than 3m.
Also, not more than one unit of any type shall be
installed in the same room.
9.
10. Cont
The minimum wall thickness of the x-ray room
should be 9 inch or 23cm solid brick or
equivalent.
There shall be no windows and ventilations shall
be above 2m from the floor outside. Table shall
be oriented such that the primary (chest stand) is
not directed towards the main door or darkroom.
The primary wall thickness shall be 35 cm of
solid brick or 32 cm solid brick + 1.5 mm LEAD
11. Guideline 3
The users should install only Atomic Energy
Regulatory Board (AERB) “Type Approved”
unit or unit with valid NOC for medical
diagnostic purpose and obtain a copy of the
AERB “Type Approval” certificate from the
supplier/manufacturer of the x-ray unit prior
to the procurement of the unit.
User may verify the Type Approval
Certificate Number from AERB in case of
any doubt.
12.
13. The users should procure and use
protective accessories such as mobile
protective barrier, lead rubber aprons, lead
rubber flaps, gloves, thyroid shields, etc.
14.
15. The employer shall provide Personnel Monitoring
Badges to all radiation workers of the institute.
For procuring personnel monitoring badges,
please contact Avanttec Laboratories Private
Limited, #31, Kamaraj Street, Srinivasa Nagar,
Padi, Chennai-600 050.
16.
17. The users should follow the guidelines given in AERB
Safety Code for Medical Diagnostic X-Ray Equipment
and Installations [Code No.AERB/SC/MED-2 (Rev.-1)].
The same can be purchased from AERB or downloaded
from AERB website www.aerb.gov.in.
The user shall comply with other regulatory documents
related to the use and operation of x-ray units that are
available in AERB website or DRS website.
18. i Atomic Energy (Radiation Protection) Rules, 2004
(G.S.R.303)
ii Radiation Surveillance Procedures for Medical
Applications of Radiation, 1989 (G.S.R.No.388)
iii Performa for “Registration of Diagnostic X-Ray
installations and Licence of Computed Tomography
(CT)/Cathlab unit Installations”.
iv Documents (i) & (ii) can be purchased from bookstalls
selling government publications or can be downloaded
from DRS website. (iii) shall be given by the Directorate
of Radiation Safety on Site Approval
19. The users should request the supplier/manufacturer
of the diagnostic x-ray units to conduct Quality
Assurance (QA) tests after the installation of x-ray
unit/computed tomography unit/mammography/
cathlab unit prior to using it for patient diagnosis,
under intimation to the DRS.
Preserve the QA tests report in the
hospital/institution record for further use and submit
a copy of QA tests report to the DRS. The unit
should be used for patient diagnosis only if its
performance is found satisfactory.
20.
21. After installation, the users should send the completely filled
and duly signed “Application for Registration of Diagnostic X-
Ray installations” / “Application for Licence of Computed
Tomography (CT) unit / Interventional Radiology (Cathlab)
Installations” (as applicable) to the Director, Directorate of
Radiation Safety, AERB for onward transmission with
recommendation to the Atomic Energy Regulatory Board for
obtaining Registration Certificate for diagnostic x-ray units
and/or License Certificate for CT Scan/Cathlab units for
operation.
22. The employer shall employ only qualified
Radiologist and Medical imaging
Technologist. The minimum qualification is
given in AERB Safety Code for Medical
Diagnostic X-Ray Equipment and
Installations [Code No.AERB/SC/MED-
2(Rev-1)]
23.
24. AERB issues notice every year in all
leading newspapers in the country (both
Hindi and English) regarding “Statutory
Requirements for Safe Operation of
Medical diagnostic X-ray units by
Hospitals, Clinics and other Medical
Institutions in India”.
28. e-LORA is a web based I&CT application
implemented by AERB to facilitate
licensing of radiation facilities.
e-governance initiative by AERB.
Objective:
Enhanced efficiency and transparency in
the regulatory processes of AERB.
Aimed at achieving paperless licensing.
29.
30. Step : 1 creation of account in e-LORAfor
user D & password.
Step 2 : Approval letter.
Step 3: QA report for applying license.
Step 4 : TLD badges for doctor, operator.
Step 5 : Qualified Technicians.
Step 6: Approved RSO.
Step 7 : Radiation License certificate.