This document analyzes and compares the design of supporting systems for circular elevated water tanks of the same 300m3 capacity located in different seismic zones (II, III, and IV) in India. The study models the tank and conducting response spectrum analysis to calculate seismic forces - shear force, axial force, and bending moment - induced on peripheral and interior columns under full and empty tank conditions. Results show seismic forces generally increase with higher seismic zone and are greater for interior columns compared to peripheral columns. For Zone IV, interior columns fail the bending moment check, indicating larger column sizes are needed. In conclusion, seismic forces on a tank's supporting structure vary significantly based on the seismic zone and column location.