I am seeking Project Manager / Project Engineering work opportunities which will utilize my varied experience with utility power delivery projects and medium voltage manufacturing projects including engineering, design, and construction management.
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
Michael Dunlap Resume - 2016
1. MICHAEL L. DUNLAP
4487 Raccoon Place, Dublin, Virginia 24084
dunlapmichaell@gmail.com
(423) 718-1946 (Cell)
OBJECTIVE
I am seeking Project Manager / Project Engineering work opportunities which will utilize my varied
experience with utility power delivery projects and medium voltage manufacturing projects including
engineering, design, and construction management.
EDUCATION
M.S. Engineering Management / Industrial Engineering, University of Tennessee, December 15, 1990, GPA
3.79 / 4.00.
B.S. Electrical Engineering , University of Tennessee, August 25, 1978. With Honors, GPA 3.23 / 4.00.
EXPERIENCE
- Power Transmission and Distribution
Project Manager for Wood Group Mustang working at Celanese Acetate Site in Narrows, VA. Responsible
for review of Electrical Substation design drawings and manufacturers’ drawings for adherence to scope and
specifications. Assured design continuity of 138kv & 6900V Protection & Control (P&C), Physical, and
Telecommunication. Projects included familiarization with Schweitzer Engineering Laboratories (SEL)
devices such as - SEL-2411 & 2440 (Remote I/O), SEL-2730 (Ethernet Switch), SEL-3354 (HMI), SEL-3530
(Front End Processor), SEL-751(OC Relay), SEL-700G (Generator Relay), SEL-587Z (Hi-Imp Diff Relay),
Multilin Power Quality Meter (PQM II), Siemens SPIROTEC relays, etc.
Provided Project Engineering support for construction of a 138kv substation consisting of replacement of a
138kv/6900v transformer and addition of MOD (motor operated disconnect), HV Circuit Switcher, Secondary
Breakers, related Arresters, CCVTS, etc. Provided review of P&C designs including transformer
differential, bus differential, transformer primary & secondary OC protection, transformer neutral,
zero-sequence relaying, SCADA, etc.
Additionally, I provided Project Engineering support for construction of a 6900v indoor substation including
installation of double bus/double breaker metal clad switchgear, 125VDC system, 120VAC instrument &
lighting systems, conduit and cable trays, etc.
Project Manager for Celanese site projects including:
Department electrical reclassification upgrade
Chemical sewer monitoring via pH and conductivity measurement
Installation of 120VAC, 12.5 KVA UPS
Installation of furnace oxygen trim systems
Addition of wireless conductivity transmitters for storm sewer monitoring
Refurbishment of 6900V/480V transformer
Replacement of 240V/240V/120V lighting transformers
Replacement of 6900V/480V, 2500KVA secondary bushing and transformer maintenance
2400V motor starter relay upgrades
2400V & 480V substation feeder relay upgrades
Consultant for Sargent & Lundy LLC
(S&L) working with Pacific Gas & Electric (PG&E) as Owner’s Engineer
for the oversight of multiple Engineering contractors including Worley Parsons and Ocampo Esta
Corporation. As PG&E Owner’s Engineer my responsibilities included 1) evaluation of contractor proposals
2. Page 2 of 5
for adherence to the Request For Proposal (RFP), 2) contractor interface with and support of PG&E’s various
Engineering & Design groups and Construction organization, 3) monitoring of contractor reporting, 4)
overview of contractor design submittals/drawings, and 5) contractor adherence to project budget and
schedule.
Manager for S&L Chattanooga Office responsible for projects associated with S&L’s Power Delivery
Services. Responsible for substation project PM role, office manpower loadings, and business
development with existing and potential clients. Served as S&L’s primary point-of-contact for substation
managed tasks performed for the Tennessee Valley Authority (TVA).
Manager of S&L Los Angeles Office serving as primary contact for Engineering tasks performed for Southern
California Edison (SCE). Responsibilities included client liaison, expansion of office presence relating to
SCE, and fulfillment of Project Management role.
Project Manager of numerous TVA Substation upgrade projects responsible for overall project cost (CPI -
Cost Performance Index), schedule, and quality. Typical projects included:
Guntersville Hydro Plant - Replacement of existing 161-115kV transformer with four single-phase
50 MVA 161-115-13.8 kV power transformers and addition of 115kV, 2000A power circuit
breaker. Tasks included physical design of pier-slab foundations and various augured
foundations for associated bus, etc. Replacement of existing protective relaying including
addition of SEL-387 transformer differential, SEL-551 over current, breaker failure, and SEL-421
& REL-512 line relays.
Colbert Fossil Plant - Replacement of twenty-seven (27) 161kV Oil Circuit Breakers with 3000A
SF6 PCBs, replacement of seventy-six (76) disconnect switches including twenty-three (23)
Motor Operated Disconnects (MODs), addition of forty-eight (48) surge arresters, addition of
Digital Fault Recorder (DFR) and SEL-2030 communication interfaces, and modification of
associated Line and Breaker Failure (BF) relaying.
Batesville, MS 161kV Substation - Replacement of existing 161kV line relays with dual
microprocessor line relay package consisting of GE “D90” and REL-670 relays operating in pilot
scheme via power line carrier and interfaced with SEL2030 communications
processor.Installation of associated wave traps, LTU, and transmitter / receivers for power line
carrier.
Power Engineer responsible for over-site of design review, design calculations, construction, equipment
specification, and commissioning of 161-kV switchyard. Construction experience including live-line
demolition of OCB switchyard and installation of SF6 GCB switchyard.
Knowledge of the design and testing of protective relay schemes including electromechanical and
programmable relays, SCADA, revenue metering systems, annunciation, ground detection units,
161/13.8-kV delta and grounded wye distribution systems, and SF6 GCBs, OCBs, & ACBs.
Developed pre-operational test protocol and completed testing of new 161kV Substation.
Performed design review of Single-line Diagrams, Three-line Diagrams, AC & DC Control Schematics,
Elementary Diagrams, Wiring Diagrams, General Arrangements, and Conduit & Grounding Drawings.
Power Engineer assigned to Martin Marietta Energy Systems (MMES) Power Operations Department.
Power Operations Department representative accountable for providing engineering support to plant
electrical safety committee. Committee was the site “authority having jurisdiction” as defined by the NEC.
3. Page 3 of 5
Power Operation Department’s Safety Officer including responsibility for the analysis and resolution of safety
related employee concerns.
Familiar with NEC 1996, OSHA 1910.269 “Standard for Electric Power Generation, Transmission, and
Distribution”, and OSHA 1910.300 series “Safety Related Work Practices.”
- Electrical
Project Manager (Wood Group Mustang) for multiple projects including : 1) oversight of assessment of the
plants 480V & 2300V substations, 2) the addition of 6900V feeder arc reduction maintenance switches –
ARMS, 3) the addition of Emerson coriolis mass flow transmitters, 4) differential pressure sensor installation
(Endress & Hauser Waterpilot) for the plant water filtration system, 5) GE Mark V generator turbine control
data logger upgrade, and 6) installation of furnace Rosemount oxygen trim system.
- Consulting
Business Development Manager responsible for extension of the commercial / industrial client base for J.
Givoo Consultants in areas geographically close to Aiken, South Carolina. J. Givoo Consultants is an A-E
firm based in New Jersey and employing approximately 140 employees.
Senior Electrical Engineer with Merrick Southeast, Engineers and Architects supporting projects involved in
the modification and upgrade of the Department of Energy’s Savannah River Site (DOE - SRS). Provided
design support for the installation of 600hp river water suction pump and associated motor operated valves
(MOVs).
Familiar with the analysis and development of coordination studies, system short circuit calculations using
ETAP software, analysis of motor thermal overload protection, and voltage drop calculations.
Project Engineer with J. Givoo Consultants supporting the Plant Validation and Readiness Team under NRC
50.54 (f). Tasks included addressing NRC licensing concerns through the review of plant operational &
administrative procedures and processes.
- Procurement and Contract Administration
Contract Administrator responsible for the solicitation and award of numerous commodity and engineering
service contracts. Contracts included $60M, five year contract for just-in-time (JIT) procurement of personal
computer systems, peripheral hardware, and workstations.
Experience in contractual negotiations with small businesses (SB, SDB) and corporations.
Familiar with evaluated procurement procedures, technical specification development, and federal
acquisition regulations.
- Hazardous Waste Management
Supervisor for shift operation of a mixed waste (hazardous/radioactive) neutralization facility processing
waste water from a Toxic Substances Control Act (TSCA) incinerator.
Management representative on Project Management Team (PMT) established to improve mixed
(hazardous/radioactive) waste water treatment facility operation, safety, and maintenance activities via Total
Quality Management (TQM).
- Instrumentation and Controls
4. Page 4 of 5
Procurement Engineer responsible for the solicitation, evaluation, and award of contracts for the purchase of
instrumentation and control equipment associated with power generation plants. Typical devices included
flow, pressure, and temperature metering and transmitters.
Instrumentation & Controls Engineer responsible for physical layout and PLC integration of instrumentation
and control devices throughout Nuclear Power Generation Plant. Evaluated instrumentation for application
of IEEE standards (and others) relating to Nuclear and general plant environments.
TRAINING
Working level knowledge of software including SAP, MS Project, Excel, Access, PowerPoint, MS Word,
WordPerfect, and Lotus Notes.
Participated in 5 day protective relaying course presented by Asea Brown Boveri (ABB).
Participated in 4 day protective relaying course presented by The Associated Training Corporation.
Participated in 2 day underground distribution system fault location seminar presented by Multi-Amp.
Participated in 5 day Substation Engineering course conducted by Sargent & Lundy LLC
Participated in MS Project training course presented at New River Community College.
Training seminars including: two seminars reviewing the 1993 NEC, 40 hour SARA/OSHA Hazwoper and
Hazard Communications training with 8 hour refresher course, Confined Space Entry Training, Carcinogen
Worker Training, and Radiation Worker Training.
Thirteen (13) years experience as an approved Navy instructor conducting classroom instruction of general
engineering and management.
WORK HISTORY
7/12 to Present Wood Group Mustang – Celanese International, Narrows, VA – Project Manager /
Project Engineer
1/00 to 3/12 Sargent & Lundy LLC
– Manager and Consultant, Power Delivery Services,
Chattanooga, TN (Tenn Valley Authority)
Manager and Consultant, Power Delivery Services, Los
Angeles, CA (Southern Cal Edison) / San Francisco, CA
(Pacific Gas & Electric)
3/98 to 1/00 Secondary Education Teacher – State of Tennessee License with endorsements in
Physics and Mathematics
5/97 to 3/98 J. Givoo Consultants, Aiken SC and Salem NJ - Manager, Commercial and
Industrial Accounts, Senior Project Engineer
9/96 to 3/97 ACTS, Inc., Aiken, SC - Senior Electrical Engineer and Project Engineer
12/88 to 3/96 Lockheed Martin Energy Systems, Oak Ridge, TN - Power Engineer, Contract
Administrator
8/78 to 8/88 TVA, Knoxville, TN and Watts Bar Nuclear Plant, Spring City, TN - Electrical
Engineer and I & C Engineer
5. Page 5 of 5
MILITARY
United States Navy Reserve / June 1982 - October 1995
Rank / Designator: Lieutenant Commander (O4) / ENGINEERING DUTY OFFICER (1445)
Commanding Officer - Yorktown Naval Weapons Station (NWS) Detachment A309. Responsibilities
included performance as Command Duty Officer of NWS-Yorktown accountable for “off-hour” receipt of
special weapons.
Engineering Duty Officer -
Charleston Naval Shipyard Detachment 209 & Portsmouth Naval Shipyard Detachment 709
LICENSE
Project Management Professional (PMP) certification application previously accepted by Project
Management Institute
State of Tennessee, Department of Education, Secondary Education, Areas of Endorsement: 1.)
Mathematics 2.) Physics