This document analyzes the seismic behavior of reinforced concrete flat slab buildings with and without shear walls using response spectrum analysis and equivalent static force method. Five models of a 7-story building are considered: a bare frame with flat slab, exterior shear wall, L-shaped shear wall, rectangular shear wall, and lift core shear wall. Results for base shear, story drift, displacement, and acceleration are obtained and compared using ETABS software for zone 5 seismicity. The analysis finds that shear walls improve seismic performance by resisting lateral loads and limiting structural deformation and damage.
STATIC LINEAR AND NON LINEAR (PUSHOVER) ANALYSIS OF RC BUILDING ON SLOPING GR...IAEME Publication
OBJECTIVE: This paper Deals with the seismic activity field investigations often verify so as to uneven constructions undergo extra harm than their common counterparts. This is known in seismic design codes, & limitations on top of sudden changes within mass & rigidity are compulsory. METHODS/ANALYSIS: Irregularity within sizes pressures sharing about rigidity, & within twist influence ability, as mass irregularity is likely to pressure compulsory required. Altitude irregularity has been observed in the direction of reason story failure due to non-uniform distribute of demand-to-supply ratios the length about length of the elevation. Plan irregularity, resting on the additional hand, reason non-uniform demand-to-capacity ratios bounded by the columns. In this paper the structure chosen for study is a 4 to 7 storey commercial complex building. The building which is located in seismic zone III, IV, & V on Medium soil sites. 3D mathematical models for the same are generated in ETABS software. FINDINGS: For all structural fundamentals, M40 Grade of material is used. The floor Diaphragms are unspecified to be rigid. Seismic loads were considered acting along either of the 2 major directions. Using ETABS a 4 to7 storey RC structure with typical ground slope choosing angle range between 00 and 400 building that which produce less torsion effect for set-back & step-back with irregular configuration in horizontal & vertical direction is modeled and analyzed. “And isolated bearing is also used that which resist during earthquake and building that which produce less torsion effect for setback - step back with irregular configuration.
A comparative study on force based design and direct displacement based desig...eSAT Journals
Abstract In recent times, many research works related to seismic resistant design of structures were done and various methods of seismic resistant design were predicted and this study explains about two major seismic design methods (i.e) Force Based Design(FBD) and Direct Displacement Based Design(DDBD) in which former is a conventional method while later one is a performance approach of design. Design and Analysis were done on two dimensional bare frames of four, eight and twelve stories based on following codes IS 456, IS 1893:2000, FEMA 356 and the two design approaches were studied. Analysis and design for this study was done using Structural Analysis Program software(SAP 2000). Both design approaches is validated using non linear time history analysis for 16 different ground motion of PGA =0.32g. Structural parameters like Drift Ratio, Ductility Demand and Base shear were compared within the frames of different stories and between design approaches. Keywords: Force Based Design (FBD), Direct Displacement Based Design (DDBD), Base Shear, Ductility, Inter storey Drift, Reinforced Concrete Frames, FEMA.
Seismic Vulnerability of RC Building With and Without Soft Storey Effect Usi...IJMER
A soft storey is one which has less resistance to earthquake forces than the other storeys;
Buildings containing soft stories are extremely vulnerable to earthquake collapses, since one floor is
flexible compared to others. Vulnerability of buildings is important in causing risk to life hence special
consideration is necessary for such soft storey RC buildings. In the present study, analytical
investigation of a RC building by considering the effect of soft storey situated in seismic Zone-V of
India, in accordance with IS 1893-2002 (part-1), is taken as an example and the various analytical
approaches (linear static and nonlinear static analysis) are performed on the building to identify the
seismic demand and also pushover analysis is performed to determine the performance levels, and
Capacity spectrum of the considered, also Storey Shear is compared for 3 models by using Finite
Element Software Package ETAB’s 9.7.4 version.
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSISIjripublishers Ijri
In plan during the seismic excitation using nonlinear static analysis (pushover) have been performed on the
same structure. The literature pertaining to pushover analysis is reviewed. The pushover analysis adopted
in the present study is on similar lines with the procedure presented by Ashraf Habibullah and Stephen
Pyle using ETABS V 9.7 structural analysis software. The effect of earthquake force in a idealized G+4 story
building under maximum earthquake zone, with the help of pushover analysis has been investigated and
the results were compared in terms of base shear, displacement, spectral acceleration, spectral displacement
and effective damping and effective time period .to strengthen the symmetric and un symmetric RCC
framed buildings` steel braces are included by using retrofitting method.
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
STATIC LINEAR AND NON LINEAR (PUSHOVER) ANALYSIS OF RC BUILDING ON SLOPING GR...IAEME Publication
OBJECTIVE: This paper Deals with the seismic activity field investigations often verify so as to uneven constructions undergo extra harm than their common counterparts. This is known in seismic design codes, & limitations on top of sudden changes within mass & rigidity are compulsory. METHODS/ANALYSIS: Irregularity within sizes pressures sharing about rigidity, & within twist influence ability, as mass irregularity is likely to pressure compulsory required. Altitude irregularity has been observed in the direction of reason story failure due to non-uniform distribute of demand-to-supply ratios the length about length of the elevation. Plan irregularity, resting on the additional hand, reason non-uniform demand-to-capacity ratios bounded by the columns. In this paper the structure chosen for study is a 4 to 7 storey commercial complex building. The building which is located in seismic zone III, IV, & V on Medium soil sites. 3D mathematical models for the same are generated in ETABS software. FINDINGS: For all structural fundamentals, M40 Grade of material is used. The floor Diaphragms are unspecified to be rigid. Seismic loads were considered acting along either of the 2 major directions. Using ETABS a 4 to7 storey RC structure with typical ground slope choosing angle range between 00 and 400 building that which produce less torsion effect for set-back & step-back with irregular configuration in horizontal & vertical direction is modeled and analyzed. “And isolated bearing is also used that which resist during earthquake and building that which produce less torsion effect for setback - step back with irregular configuration.
A comparative study on force based design and direct displacement based desig...eSAT Journals
Abstract In recent times, many research works related to seismic resistant design of structures were done and various methods of seismic resistant design were predicted and this study explains about two major seismic design methods (i.e) Force Based Design(FBD) and Direct Displacement Based Design(DDBD) in which former is a conventional method while later one is a performance approach of design. Design and Analysis were done on two dimensional bare frames of four, eight and twelve stories based on following codes IS 456, IS 1893:2000, FEMA 356 and the two design approaches were studied. Analysis and design for this study was done using Structural Analysis Program software(SAP 2000). Both design approaches is validated using non linear time history analysis for 16 different ground motion of PGA =0.32g. Structural parameters like Drift Ratio, Ductility Demand and Base shear were compared within the frames of different stories and between design approaches. Keywords: Force Based Design (FBD), Direct Displacement Based Design (DDBD), Base Shear, Ductility, Inter storey Drift, Reinforced Concrete Frames, FEMA.
Seismic Vulnerability of RC Building With and Without Soft Storey Effect Usi...IJMER
A soft storey is one which has less resistance to earthquake forces than the other storeys;
Buildings containing soft stories are extremely vulnerable to earthquake collapses, since one floor is
flexible compared to others. Vulnerability of buildings is important in causing risk to life hence special
consideration is necessary for such soft storey RC buildings. In the present study, analytical
investigation of a RC building by considering the effect of soft storey situated in seismic Zone-V of
India, in accordance with IS 1893-2002 (part-1), is taken as an example and the various analytical
approaches (linear static and nonlinear static analysis) are performed on the building to identify the
seismic demand and also pushover analysis is performed to determine the performance levels, and
Capacity spectrum of the considered, also Storey Shear is compared for 3 models by using Finite
Element Software Package ETAB’s 9.7.4 version.
DESIGN AND ANALYSIS OF MULTI STORIED STRUCTURES USING STATIC NON LINEAR ANALYSISIjripublishers Ijri
In plan during the seismic excitation using nonlinear static analysis (pushover) have been performed on the
same structure. The literature pertaining to pushover analysis is reviewed. The pushover analysis adopted
in the present study is on similar lines with the procedure presented by Ashraf Habibullah and Stephen
Pyle using ETABS V 9.7 structural analysis software. The effect of earthquake force in a idealized G+4 story
building under maximum earthquake zone, with the help of pushover analysis has been investigated and
the results were compared in terms of base shear, displacement, spectral acceleration, spectral displacement
and effective damping and effective time period .to strengthen the symmetric and un symmetric RCC
framed buildings` steel braces are included by using retrofitting method.
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Descriptive study of pushover analysis in rcc structures of rigid jointYousuf Dinar
ABSTRACT: Structures in mega cities, are under serious threat because of faulty and unskilled design and construction of structures. Sometimes structure designers are more concerned in constructing different load resistant members without knowing its necessity and its performance in the structure. Different configuration of construction may also lead to significant variation in capacity of the same structure. Nonlinear static pushover analysis provides a better view on the performance of the structures during seismic events. This comprehensive research evaluates as well as compares the performances of bare, different infill percentage level, different configuration of soft storey and Shear wall consisting building structures with each other and later depending upon the findings, suggests from which level of performance shear wall should be preferred over the infill structure and will eventually help engineers to decide where generally the soft storey could be constructed in the structures. Above all a better of effects of pushover analysis could be summarized from the findings. Masonry walls are represented by equivalent strut according to pushover concerned codes. For different loading conditions, the performances of structures are evaluated with the help of performance point, base shear, top displacement, storey drift and stages of number of hinges form.
Performance Based Evaluation of Shear Walled RCC Building by Pushover AnalysisIJMER
International Journal of Modern Engineering Research (IJMER) is Peer reviewed, online Journal. It serves as an international archival forum of scholarly research related to engineering and science education.
International Journal of Modern Engineering Research (IJMER) covers all the fields of engineering and science: Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Computer Engineering, Agricultural Engineering, Aerospace Engineering, Thermodynamics, Structural Engineering, Control Engineering, Robotics, Mechatronics, Fluid Mechanics, Nanotechnology, Simulators, Web-based Learning, Remote Laboratories, Engineering Design Methods, Education Research, Students' Satisfaction and Motivation, Global Projects, and Assessment…. And many more.
The Pushover Analysis from basics - Rahul LeslieRahul Leslie
Pushover analysis has been in the academic-research arena for quite long. The papers published in this field usually deals mostly with proposed improvements to the approach, expecting the reader to know the basics of the topic... while the common structural design practitioner, not knowing the basics, is left out from participating in those discussions. Here I’m making an effort to bridge that gap by explaining the Pushover analysis, from basics, in its simplicity.
A write up on this topic can be found at http://rahulleslie.blogspot.in/p/blog-page.html, though does not cover the full spectrum presented in this slide show.
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...Ijripublishers Ijri
In the recent years a lot of attention has been given to the earthquake analysis of structure it is one of the most devastating
natural calamity and which causes severe damage not only to the properties but also to the lives. This is the
reason there has been a lot of focus on the structures to be earthquake resistant. Buildings get damaged mostly due
to the earthquake ground motions. In an earthquake, the building base experiences high frequency movements, which
results in the inertial force on the building and its components and this problem gets worse when a structure is irregular
in shape, size etc,. Therefore, there is a lot to work on the seismic behavior of the irregular building which might not
respond the way regular building does. It makes the irregular building quite more complex and unpredictable during
the course of an earthquake.
Variation of deflection of steel high rise structure due to p- delta effect c...Yousuf Dinar
Abstract—This paper evaluates deflection of the steel high rise structure due to the P-Delta effect considering the global slenderness of the whole structure. For easy and quick design only Linear Static analysis is performed and secondary loading effect is neglected in several underdeveloped and developing countries of South Asia. Using STAADPro v8i, 40 different model is simulated to observe the severity of the P-Delta phenomenon against standard Linear Static method. 4 different storey were combined with 5 varying span in both direction for varying the slenderness of the structure. During analysis lateral load imposed with UBC94 to perform the seismic events in two directions in the seismic moderate risk zone of Bangladesh using Bangladesh National Building Code (BNBC) corresponding coefficients however wind load is omitted to observe the seismic event effect in Steel high-rise structure solely assuming outcome decision would be same if the simulation would done for wind load also. This analysis reveals how crucial side of the structure generates different deflections with changing slenderness. Test results were evaluated by storey deflection (in mm) and percentage of variation of deflection was performed by comparing P-Delta outputs with Linear Static Method outputs.
Descriptive study of pushover analysis in rcc structures of rigid jointYousuf Dinar
ABSTRACT: Structures in mega cities, are under serious threat because of faulty and unskilled design and construction of structures. Sometimes structure designers are more concerned in constructing different load resistant members without knowing its necessity and its performance in the structure. Different configuration of construction may also lead to significant variation in capacity of the same structure. Nonlinear static pushover analysis provides a better view on the performance of the structures during seismic events. This comprehensive research evaluates as well as compares the performances of bare, different infill percentage level, different configuration of soft storey and Shear wall consisting building structures with each other and later depending upon the findings, suggests from which level of performance shear wall should be preferred over the infill structure and will eventually help engineers to decide where generally the soft storey could be constructed in the structures. Above all a better of effects of pushover analysis could be summarized from the findings. Masonry walls are represented by equivalent strut according to pushover concerned codes. For different loading conditions, the performances of structures are evaluated with the help of performance point, base shear, top displacement, storey drift and stages of number of hinges form.
Performance Based Evaluation of Shear Walled RCC Building by Pushover AnalysisIJMER
International Journal of Modern Engineering Research (IJMER) is Peer reviewed, online Journal. It serves as an international archival forum of scholarly research related to engineering and science education.
International Journal of Modern Engineering Research (IJMER) covers all the fields of engineering and science: Electrical Engineering, Mechanical Engineering, Civil Engineering, Chemical Engineering, Computer Engineering, Agricultural Engineering, Aerospace Engineering, Thermodynamics, Structural Engineering, Control Engineering, Robotics, Mechatronics, Fluid Mechanics, Nanotechnology, Simulators, Web-based Learning, Remote Laboratories, Engineering Design Methods, Education Research, Students' Satisfaction and Motivation, Global Projects, and Assessment…. And many more.
The Pushover Analysis from basics - Rahul LeslieRahul Leslie
Pushover analysis has been in the academic-research arena for quite long. The papers published in this field usually deals mostly with proposed improvements to the approach, expecting the reader to know the basics of the topic... while the common structural design practitioner, not knowing the basics, is left out from participating in those discussions. Here I’m making an effort to bridge that gap by explaining the Pushover analysis, from basics, in its simplicity.
A write up on this topic can be found at http://rahulleslie.blogspot.in/p/blog-page.html, though does not cover the full spectrum presented in this slide show.
PERFORMANCE BASED ANALYSIS OF VERTICALLY IRREGULAR STRUCTURE UNDER VARIOUS SE...Ijripublishers Ijri
In the recent years a lot of attention has been given to the earthquake analysis of structure it is one of the most devastating
natural calamity and which causes severe damage not only to the properties but also to the lives. This is the
reason there has been a lot of focus on the structures to be earthquake resistant. Buildings get damaged mostly due
to the earthquake ground motions. In an earthquake, the building base experiences high frequency movements, which
results in the inertial force on the building and its components and this problem gets worse when a structure is irregular
in shape, size etc,. Therefore, there is a lot to work on the seismic behavior of the irregular building which might not
respond the way regular building does. It makes the irregular building quite more complex and unpredictable during
the course of an earthquake.
Variation of deflection of steel high rise structure due to p- delta effect c...Yousuf Dinar
Abstract—This paper evaluates deflection of the steel high rise structure due to the P-Delta effect considering the global slenderness of the whole structure. For easy and quick design only Linear Static analysis is performed and secondary loading effect is neglected in several underdeveloped and developing countries of South Asia. Using STAADPro v8i, 40 different model is simulated to observe the severity of the P-Delta phenomenon against standard Linear Static method. 4 different storey were combined with 5 varying span in both direction for varying the slenderness of the structure. During analysis lateral load imposed with UBC94 to perform the seismic events in two directions in the seismic moderate risk zone of Bangladesh using Bangladesh National Building Code (BNBC) corresponding coefficients however wind load is omitted to observe the seismic event effect in Steel high-rise structure solely assuming outcome decision would be same if the simulation would done for wind load also. This analysis reveals how crucial side of the structure generates different deflections with changing slenderness. Test results were evaluated by storey deflection (in mm) and percentage of variation of deflection was performed by comparing P-Delta outputs with Linear Static Method outputs.
Seismic performance of r c buildings on sloping grounds with different types ...eSAT Journals
Abstract
Structure are highly susceptible to serve damages in earthquake scenario, so choosing an appropriate lateral force resisting
bracing systems will have a significant effect on performance of the structure. So this present study is aimed at evaluating and
comparing various types of eccentric steel bracings for 12 storey RC frame building resisting on sloping ground configurations.
For this 5 types of bracing systems like X-Bracing, Diagonal bracing, K- bracing, V-bracing and inverted V bracing are
considered on the outer periphery of the buildings with step back and set back – step back type configurations are modeled and
analyzed. The models are compared for different aspects within the structure, such as the maximum storey displacement, base
shear, storey drift and storey shear, the structure is analyzed for seismic zone V and medium soil condition as per IS 1893:2002
using ETABS software. Results conclude that on sloping ground due to irregularity on ground surface, the structures are more
vulnerable to earthquakes. Hence use of eccentric steel bracing is an effective and economical way to resist earthquake forces,
Inverted V type bracing performs well compared to other bracing types. By using inverted V type bracing in step back buildings
types maximum storey displacement of 70% and storey drift of 66% are obtained. Similarly for setback – step back configuration
maximum storey displacement of 74% and storey drift of 70% are obtained respectively.
Keywords: X-Bracing, Diagonal Bracing, K- Bracing, V-Bracing and Inverted V Bracing
Dynamic Response of High Rise Structures Under The Influence of Shear WallsIJERA Editor
This study presents the procedure for seismic performance estimation of high-rise buildings based on a concept of the capacity spectrum method. In 3D analytical model of thirty storied buildings have been generated for symmetric buildings Models and analyzed using structural analysis tool ETABS. The analytical model of the building includes all important components that influence the mass, strength, stiffness and deformability of the structure. To study the effect of concrete core wall & shear wall at different positions during earthquake, seismic analysis using both linear static, linear dynamic and non-linear static procedure has been performed. The deflections at each storey level has been compared by performing Equivalent static, response spectrum method as well as pushover method has also been performed to determine capacity, demand and performance level of the considered building models. From the below studies it has been observed that non-linear pushover analysis provide good estimate of global as well as local inelastic deformation demands and also reveals design weakness that may remain hidden in an elastic analysis and also the performance level of the structure. Storey drifts are found within the limit as specified by code (IS: 1893-2002) in Equivalent static, linear dynamic & non-linear static analysis.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
CW RADAR, FMCW RADAR, FMCW ALTIMETER, AND THEIR PARAMETERSveerababupersonal22
It consists of cw radar and fmcw radar ,range measurement,if amplifier and fmcw altimeterThe CW radar operates using continuous wave transmission, while the FMCW radar employs frequency-modulated continuous wave technology. Range measurement is a crucial aspect of radar systems, providing information about the distance to a target. The IF amplifier plays a key role in signal processing, amplifying intermediate frequency signals for further analysis. The FMCW altimeter utilizes frequency-modulated continuous wave technology to accurately measure altitude above a reference point.
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.