Magnatrol Valve provides high quality bronze and stainless steel solenoid valves, temperatures to 400F, pressures to 500 PSI, for control of water, oil, steam, air, gas, cryogenics, solvents, oxygen, and corrosive fluids.
Process Dynamics and Control (2007 Edition) (Hardbound)
By K. T. Jadhav
Size : B5, Pages: 428; Price : Rs. 390.00
Buy this book from : www.chinttanpublications.in
Process Dynamics and Control (2007 Edition) (Hardbound)
By K. T. Jadhav
Size : B5, Pages: 428; Price : Rs. 390.00
Buy this book from : www.chinttanpublications.in
Pneumatic control valve
Actual Pneumatic Control Valve
Typical Actuator & Valve
introduction to actuator
Actuator power
Actuator Fluids
Diaphragm Actuator
Positioner Indicator
Valve Body
Valve Plugs
Reverse & Direct Actuators
Air-To-Open vs. Air-To-Close
control valve
Controller Tuning
Selection of controller modes
Tuning Rules
Ziegler – Nichols Controller Settings
Pressure Safety Valve Sizing - API 520/521/526Vijay Sarathy
No chemical process facility is immune to the risk of overpressure to avoid dictating the necessity for overpressure protection. For every situation that demands safe containment of process gas, it becomes an obligation for engineers to equally provide pressure relieving and flaring provisions wherever necessary. The levels of protection are hierarchical, starting with designing an inherently safe process to avoid overpressure followed by providing alarms for operators to intervene and Emergency Shutdown provisions through ESD and SIL rated instrumentation. Beyond these design and instrument based protection measures, the philosophy of containment and abatement steps such as pressure relieving devices, flares, physical dikes and Emergency Response Services is employed
A Control Valve is the most commonly used
final control element used to regulate fluid flow in
a process. In a process, normally it is the only
controllable element residing in the loop.
Ø This is a device used to modulate flow of
process fluid in pipe lines by creating a variable
area in the flow path.
Ø The flow path is varied with respect to the
control signal received from the controller
towards the required flow modulation.
This presentation provides an introductory look at motor operated valves, with a focus on the manufacturer Limitorque. The document includes the theory of operation of MOVs plus descriptions of valve types, such as gate, globe, ball, plug and butterfly.
This document also provides detailed descriptions of Limitorque SMB Actuators and Limitorque SB Actuators with assembly and subassembly breakdown.
Document provided by NRC.gov
Control of Continuous Distillation Columns
0 INTRODUCTION/PURPOSE
1 SCOPE
2 FIELD OF APPLICATION
3 DEFINITIONS
4 GENERAL DESCRIPTION OF A DISTILLATION COLUMN
5 REGULATORY CONTROL
5.1 Composition Control
5.2 Mass Balance Control
5.3 Design of Feedback Control Systems
5.4 Pressure and Condensation Control
5.5 Reboiler Control
6 DISTURBANCE COMPENSATION
6.1 Feed-forward Control
6.2 Cascade Control
6.3 Internal Reflux Control
7 CONSTRAINT CONTROL
7.1 Override Controls
7.2 Flooding
7.3 Limiting Control
8 MORE ADVANCED TOPICS
8.1 Temperature Position Control
8.2 Inferential Measurement
8.1 Floating Pressure Control
8.2 Model Based Predictive Control
8.1 Control of Side-streams
8.2 Extractive/Azeotropic Systems
9 REFERENCES
TABLES
1 SYMPTOMS OF IMBALANCE AND THE REGULATORY VARIABLES
2 PRACTICAL LINKAGES BETWEEN CONTROL
(P, R, B, C) AND REGULATION VARIABLES
(h, r, d, b, c, v)
3 COMPOSITION REGULATION
4 COMPOSITION REGULATION - VERY SMALL FLOWS
Safety is the most important factor in designing a process system. Some undesired conditions might happen leading to damage in a system. Control systems might be installed to prevent such conditions, but a second safety device is also needed. One kind of safety device which is commonly used in the processing industry is the relief valve. A relief valve is a type of valve to control or limit the pressure in a system by allowing the pressurised fluid to flow out from the system.
Steam Turbine Lube Oil System Protections Using SCADA & PLCNilesh Jha
Steam Turbine Protection System is designed with today technology to operate the thermal power plants in safe and reliable manner. The protection system operates only when any of the control system set point parameter is exceeded, and the steam turbine will damaged if it continues to operate. This paper presents overview of the steam turbine protection logics of lube of system and implementation for smooth automatic operation by using SIMATIC S7 PLC programming along with monitoring SCADA SYSTEM by using WinCC software.
Demand for high quality, greater efficiency and an automated machine has increased day by day in the industrial sector as well as power plants [1]. Power plants require continuous monitoring and inspection at frequent intervals. There are possibilities of errors at measuring and various stages involved with human workers and also the lack of few features of microcontrollers. Thus this paper takes a sincere attempt to explain the advantages that will be obtained by implementing automation system. The turbine lube oil system control which is the most important part of any power plant, and its automation is the precise effort of this paper. In order to automate a power plant and minimize human intervention, there is a need to develop PLC based system along with monitoring SCADA system that monitors the plant and helps reduce the errors caused by humans [2]. The internal storage of instruction of PLC is used for implementing function to control various types of machines and processes through digital or analog input/output modules. PLC systems are used to monitor and control a plant or equipment in industries such as power plants, energy, oil and gas refining and transportation.
Compressed Air Dryer Products for Industrial ApplicationsMiller Energy, Inc.
Compressed air drying products and equipment lower compressed air dewpoint for better equipment efficiency. Various methods and technologies are employed, each having a maximum low dewpoint limitation and other aspects that will make it suitable for a range of applications.
Pneumatic control valve
Actual Pneumatic Control Valve
Typical Actuator & Valve
introduction to actuator
Actuator power
Actuator Fluids
Diaphragm Actuator
Positioner Indicator
Valve Body
Valve Plugs
Reverse & Direct Actuators
Air-To-Open vs. Air-To-Close
control valve
Controller Tuning
Selection of controller modes
Tuning Rules
Ziegler – Nichols Controller Settings
Pressure Safety Valve Sizing - API 520/521/526Vijay Sarathy
No chemical process facility is immune to the risk of overpressure to avoid dictating the necessity for overpressure protection. For every situation that demands safe containment of process gas, it becomes an obligation for engineers to equally provide pressure relieving and flaring provisions wherever necessary. The levels of protection are hierarchical, starting with designing an inherently safe process to avoid overpressure followed by providing alarms for operators to intervene and Emergency Shutdown provisions through ESD and SIL rated instrumentation. Beyond these design and instrument based protection measures, the philosophy of containment and abatement steps such as pressure relieving devices, flares, physical dikes and Emergency Response Services is employed
A Control Valve is the most commonly used
final control element used to regulate fluid flow in
a process. In a process, normally it is the only
controllable element residing in the loop.
Ø This is a device used to modulate flow of
process fluid in pipe lines by creating a variable
area in the flow path.
Ø The flow path is varied with respect to the
control signal received from the controller
towards the required flow modulation.
This presentation provides an introductory look at motor operated valves, with a focus on the manufacturer Limitorque. The document includes the theory of operation of MOVs plus descriptions of valve types, such as gate, globe, ball, plug and butterfly.
This document also provides detailed descriptions of Limitorque SMB Actuators and Limitorque SB Actuators with assembly and subassembly breakdown.
Document provided by NRC.gov
Control of Continuous Distillation Columns
0 INTRODUCTION/PURPOSE
1 SCOPE
2 FIELD OF APPLICATION
3 DEFINITIONS
4 GENERAL DESCRIPTION OF A DISTILLATION COLUMN
5 REGULATORY CONTROL
5.1 Composition Control
5.2 Mass Balance Control
5.3 Design of Feedback Control Systems
5.4 Pressure and Condensation Control
5.5 Reboiler Control
6 DISTURBANCE COMPENSATION
6.1 Feed-forward Control
6.2 Cascade Control
6.3 Internal Reflux Control
7 CONSTRAINT CONTROL
7.1 Override Controls
7.2 Flooding
7.3 Limiting Control
8 MORE ADVANCED TOPICS
8.1 Temperature Position Control
8.2 Inferential Measurement
8.1 Floating Pressure Control
8.2 Model Based Predictive Control
8.1 Control of Side-streams
8.2 Extractive/Azeotropic Systems
9 REFERENCES
TABLES
1 SYMPTOMS OF IMBALANCE AND THE REGULATORY VARIABLES
2 PRACTICAL LINKAGES BETWEEN CONTROL
(P, R, B, C) AND REGULATION VARIABLES
(h, r, d, b, c, v)
3 COMPOSITION REGULATION
4 COMPOSITION REGULATION - VERY SMALL FLOWS
Safety is the most important factor in designing a process system. Some undesired conditions might happen leading to damage in a system. Control systems might be installed to prevent such conditions, but a second safety device is also needed. One kind of safety device which is commonly used in the processing industry is the relief valve. A relief valve is a type of valve to control or limit the pressure in a system by allowing the pressurised fluid to flow out from the system.
Steam Turbine Lube Oil System Protections Using SCADA & PLCNilesh Jha
Steam Turbine Protection System is designed with today technology to operate the thermal power plants in safe and reliable manner. The protection system operates only when any of the control system set point parameter is exceeded, and the steam turbine will damaged if it continues to operate. This paper presents overview of the steam turbine protection logics of lube of system and implementation for smooth automatic operation by using SIMATIC S7 PLC programming along with monitoring SCADA SYSTEM by using WinCC software.
Demand for high quality, greater efficiency and an automated machine has increased day by day in the industrial sector as well as power plants [1]. Power plants require continuous monitoring and inspection at frequent intervals. There are possibilities of errors at measuring and various stages involved with human workers and also the lack of few features of microcontrollers. Thus this paper takes a sincere attempt to explain the advantages that will be obtained by implementing automation system. The turbine lube oil system control which is the most important part of any power plant, and its automation is the precise effort of this paper. In order to automate a power plant and minimize human intervention, there is a need to develop PLC based system along with monitoring SCADA system that monitors the plant and helps reduce the errors caused by humans [2]. The internal storage of instruction of PLC is used for implementing function to control various types of machines and processes through digital or analog input/output modules. PLC systems are used to monitor and control a plant or equipment in industries such as power plants, energy, oil and gas refining and transportation.
Compressed Air Dryer Products for Industrial ApplicationsMiller Energy, Inc.
Compressed air drying products and equipment lower compressed air dewpoint for better equipment efficiency. Various methods and technologies are employed, each having a maximum low dewpoint limitation and other aspects that will make it suitable for a range of applications.
The Model 1078 is a pilot-operated valve, specifically designed to reduce blanketing gas losses on lowpressure storage tanks. It opens and closes automatically as required, to maintain a closely controlled blanket pressure. The simple design, increases reliability and lowers maintenance cost.
Brooks Instrument manufactures an array of flow, pressure, vacuum and level products for dozens of industries from pharmaceuticals, oil and gas, fuel cell research and chemicals, to medical devices, analytical instrumentation, semiconductor manufacturing.
Combustion sources such as furnaces and fired
heaters play a critical role in the process industry.
Unfortunately, combustion requires large amounts of
fuel (gas, fuel oil). As a result, combustion efficiency
directly influences the performance and operational
costs of production facilities. However, efficiency is not
the only concern. Compliance and safety are major
challenges as well.
Complete industrial electric heating element catalog including cartridge, band, tubular, screw plug, flexible, and cable heating elements. Reference for electric heating applications and OEM design. Courtesy of Belilove Company-Engineers and Hotwatt.
Our monthly sale catalog, Enco HOTdeals is packed with great deals on machinery, tools and supplies. You'll discover unique deals and sales events not found anywhere else!
7 basic valve questions to specify the correct valveDesign World
There are many factors to consider when specifying the correct valve for your application and every application is different. These conditions could be the media, temperature, compatibility, coil voltage, wattage, or explosion proof, even pressure ratings. All these considerations have an impact on specifying the correct valve to ensure millions of maintenance free cycles. This webinar will talk about the 7 valve questions you need to ask.
View this webinar to learn:
What questions to ask when specifying a Valve that is right for you.
How to get the most life from your solenoid valve because you accurately specked in your valve.
Worcester Controls Industrial Valve and Actuator Catalog 2018Ives Equipment
Catalog for Flowserve Worcester Control industrial ball valves, pneumatic actuators and electric actuators, courtesy of Ives Equipment. Threaded, flanged, socket weld, cryogenic, Navy Approved,
WOM Cementing and Circulating hose loops utilize the combination of WOM’s swivel joint flexibility and hose design for easy connection and storage for transportation.
Integral Connections, Integral Connections Oilfield Equipment - WOM Groupwomgroup
WOM Group provides Well Service Solutions including integral connections. All Integral Connections are subjected to controlled heat-treat processes to help integrity.
Wika is the leading global manufacturer of pressure and temperature measurement instrumentation, producing more than 43 million pressure gauges, diaphragm seals, pressure transmitters, thermometers and other instruments annually. WIKA’s extensive product line, including mechanical and electronic instruments, provides measurement solutions for any application in a large variety of industries.
Válvula utilizada para la regulación del caudal en una tubería que contiene un elemento tipo disco móvil y un anillo estacionario en un cuerpo generalmente esférico.
Las válvulas de globo se llaman así por su cuerpo esférico y sus dos mitades separadas por una o varias pantallas internas. Éste tiene una apertura que forma un asiento donde un tapón movible puede ser roscado para cerrar la válvula.
Valve used for regulating the flow in piping that contains a mobile disk type element and a stationary ring in a generally spherical body.
Globe valves are so called due to their spherical body and their two halves separated by one or several internal screens.
Similar to Industrial Solenoid Valves, Bronze and Stainless Steel (20)
Flow & Pressure Instrumentation for Biopharmaceuticals & Life SciencesMiller Energy, Inc.
Producing biopharmaceuticals is one of the world’s most demanding manufacturing processes. Brooks Instrument’s mass flow and pressure control technology helps maximize cell culture yields and control bioprocess costs. Brooks flow and pressure controllers set global standards for reliability, repeatability and long-term stability.
One Series Safety Transmitter - Pressure and Temperature Transmitter-SwitchMiller Energy, Inc.
The One Series Safety Transmitter simplifies installation, improves productivity, and eliminates nuisance trips. Sensor diagnostics with redundant data processing detect open, shorted, and plugged sensing elements.
Magnetrol Guide Wave Radar Level Transmitter For Hygienic ApplicationsMiller Energy, Inc.
For hygienic applications, the transmitters are available with a 304 stainless steel housings designed specifically for use in facilities with the special requirements for the wetted and non-wetted materials, process connections and surface finishes of hygienic industries.
Solenoid Valves for Water Conditioning and Purification Systems and EquipmentMiller Energy, Inc.
New composite valve technologies can offer notable benefits
when improved valves are specified for membrane-based filtration like reverse osmosis systems. Advantages include current certifications, ready availability, high reliability in challenging applications, ease of installation and use, and a choice of normally open and normally closed versions
Special RTD Temperature Sensor Configuration for Heat Trace ApplicationsMiller Energy, Inc.
Heat traced piping requires a means of temperature measurement to assure control of heat input to minimize energy consumption and maximize pipe and fluid temperature.
Maintenance Procedures for Yokogawa ADMAG TI Series AXW Magnetic Flow MeterMiller Energy, Inc.
The AXW series is ideal for industrial process lines, and water supply and sewage applications. With outstanding reliability and ease of operation, developed on decades of field-proven experience, the AXW will increase user benefits while reducing total cost of ownership.
Regulatory modifications have raised important issues in design and use of industrial safety systems. Certain changes in IEC 61508, now being widely implemented, mean that designers and users who desire full compliance must give new consideration to topics such as SIL levels and the transition to new methodologies.
Eclipse Model 706 High Performance Guided Wave Radar Level TransmitterMiller Energy, Inc.
The Eclipse® Model 706 high performance transmitter is a loop-powered, 24 VDC level transmitter that is based upon the proven and increasingly accepted technology of guided wave radar (GWR). Encompassing a number of significant engineering accomplishments, this leading edge level transmitter is designed to provide measurement performance well beyond that of many of the more traditional technologies.
Schubert & Salzer is a fast growing high-tech company, that develops, produces and distributes highly precise control and stop valves which are applied in the process industry.
Achieve superior accuracy and unmatched zero stability in ultra-low-flow gas and liquid measurement and control with the Quantim® Coriolis mass flow controllers and meters from Brooks Instrument. Brooks has taken the lead in driving improvements in Coriolis flow technology: Our patented Coriolis sensor design measures low flows independent of fluid type or process variables. The result: unsurpassed performance - the most accurate, stable, repeatable and reproducible mass flow measurement and control, even under changing conditions.
Verbatim Gateway is a field-proven, stand-alone alarm monitoring and reporting solution. More reliable than PC-based alarm systems, you can depend on it to perform in mission-critical applications due to its fault tolerance and internal battery backup. Robust yet affordable, Verbatim Gateway monitors operations and notifies personnel of problem conditions — anytime, anywhere — for a one-time cost. No extra service contracts or plug-ins required!
Parker manufactures one of the widest offerings of quick connect hose fittings available, with variants, options, and specialized products to suit almost every application.
Rugged, NEMA 4X, epoxy coated enclosure
SPDT or DPDT switch output
Easy access wiring
Single switch output
Internal reference scale and adjustable deadband available
Adjustable ranges: ◦30 "Hg Vac to 5000 psi
• 1 bar Vac to 344 bar
• 0.2 "wcd to 500 psid
• 0,5 mbar d to 34,5 bar d
• -180 to 650 ºF
• -117 to 340ºC
Approvals: UL, CSA, CE, TUV
A straight forward device, the current to pneumatic converter produces a pneumatic output signal that is proportional to an electrical control level input signal of 4 to 20 mA or 10 to 50 mA. This provides a useful interface between electronic controllers and pneumatically operated valves, air cylinders, or other air operated control elements.
The Vanguard WirelessHART gas detector is ideal for the monitoring of toxic and combustible gases without the need for costly and fixed wiring. With a five year battery life and one button calibration, the Vanguard detector is easy to operate and maintain.
Each Vanguard detector has a WirelessHART transceiver, an antenna, a display, a long life power module, a gas sensor, and a signal processor for the gas sensor. Vanguard uses a sensor architecture trademarked “Flexsense,” which allows the sensor to identify its target gas and self-configure to a Vanguard transmitter upon connection.
Magnetrol is a globally recognized manufacturer of level and flow measurement instrumentation and devices. Technologies include inferential and direct measurement.
Making the best instrument selection for a flow measurement application should include an assessment of what the operators really need in order to safely and effectively run the process or perform the task related to the measurement of fluid flow.
Habonim Valves & Actuators is a leading manufacturer of ball valves and pneumatic actuators with over 50 years' experience and a worldwide reputation for its high quality, innovation and engineering expertise. Habonim supplies a wide range of 3-piece and flanged ball valves, as well as tailor-made solutions, generating significant cost and space savings for its customers.
Magnetrol International has launched the PULSAR Model R86 Non-Contact Radar transmitter, an advanced level control solution that offers radar technology with improved performance for a wide range of level measurement applications.
The PULSAR Model R86 is designed to provide
outstanding accuracy, reliability and safety for
virtually all process industries.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Quality defects in TMT Bars, Possible causes and Potential Solutions.PrashantGoswami42
Maintaining high-quality standards in the production of TMT bars is crucial for ensuring structural integrity in construction. Addressing common defects through careful monitoring, standardized processes, and advanced technology can significantly improve the quality of TMT bars. Continuous training and adherence to quality control measures will also play a pivotal role in minimizing these defects.
Courier management system project report.pdfKamal Acharya
It is now-a-days very important for the people to send or receive articles like imported furniture, electronic items, gifts, business goods and the like. People depend vastly on different transport systems which mostly use the manual way of receiving and delivering the articles. There is no way to track the articles till they are received and there is no way to let the customer know what happened in transit, once he booked some articles. In such a situation, we need a system which completely computerizes the cargo activities including time to time tracking of the articles sent. This need is fulfilled by Courier Management System software which is online software for the cargo management people that enables them to receive the goods from a source and send them to a required destination and track their status from time to time.
Automobile Management System Project Report.pdfKamal Acharya
The proposed project is developed to manage the automobile in the automobile dealer company. The main module in this project is login, automobile management, customer management, sales, complaints and reports. The first module is the login. The automobile showroom owner should login to the project for usage. The username and password are verified and if it is correct, next form opens. If the username and password are not correct, it shows the error message.
When a customer search for a automobile, if the automobile is available, they will be taken to a page that shows the details of the automobile including automobile name, automobile ID, quantity, price etc. “Automobile Management System” is useful for maintaining automobiles, customers effectively and hence helps for establishing good relation between customer and automobile organization. It contains various customized modules for effectively maintaining automobiles and stock information accurately and safely.
When the automobile is sold to the customer, stock will be reduced automatically. When a new purchase is made, stock will be increased automatically. While selecting automobiles for sale, the proposed software will automatically check for total number of available stock of that particular item, if the total stock of that particular item is less than 5, software will notify the user to purchase the particular item.
Also when the user tries to sale items which are not in stock, the system will prompt the user that the stock is not enough. Customers of this system can search for a automobile; can purchase a automobile easily by selecting fast. On the other hand the stock of automobiles can be maintained perfectly by the automobile shop manager overcoming the drawbacks of existing system.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
2. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-INDEX
WELCOME TO MAGNATROL
22
Magnatrol Valve Corp.
• Established 1936
• Experienced Dedicated Sales Staff
• Application / Engineering Assistance
• Excellent Product Support
• Quick Delivery
Our continued success has come from manufacturing a
top quality product, product support, commitment to
service and on-time delivery assuring complete customer
satisfaction.
Process Control Solenoid Valves For
Water • Oil • Air • Gas • Steam • Cryogenics •Vacuum • Solvents • Brine • Oxygen • Corrosive Fluids
* Custom Engineered Valves, Special Alloys,
Temperatures, Pressures and Applications as well as
Modifications to Standard Magnatrol Valves are
available through Magnatrol’s Clark-Cooper Division.
(See bottom of page 3)
Our Products
Every valve is manufactured and tested
in-house following Quality Assurance
Standards where production operations
are under the control of our dedicated,
experienced staff and workforce.
• High Quality Bronze and Stainless Steel SolenoidValves*
• Pressures up to 500 PSI *
• Temperatures up to 400° F *
• Cryogenic and Oxygen Service Applications
• Normally Closed (Energize to Open)
• Normally Open (Energize to Close)
• Continuous Duty Coils for all AC & DC Voltages
• NO Differential Pressure Required to Open
• Full Port-Internal Pilot Operated or Direct Acting
• 2-Way Straight Thru Design
• Packless Construction
TABLE OF CONTENTS
Category Pages(s)
Coils. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Construction Features. . . . . . . . . . . . . . . . . . . . . . 5
Bronze Valves
N & NR. . . . . . . . . . . . . . . . . . . . . . . . . 6 & 7
A & AR . . . . . . . . . . . . . . . . . . . . . . . . . 8 & 9
M & MR . . . . . . . . . . . . . . . . . . . . . . . 10 & 11
S & SR . . . . . . . . . . . . . . . . . . . . . . . . 12 & 13
L & LR. . . . . . . . . . . . . . . . . . . . . . . . . 14 & 15
G & GR . . . . . . . . . . . . . . . . . . . . . . . . 16 & 17
D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Stainless Steel Valves
J & JR . . . . . . . . . . . . . . . . . . . . . . . . . 20 & 21
K & KR . . . . . . . . . . . . . . . . . . . . . . . . 22 & 23
W & WR . . . . . . . . . . . . . . . . . . . . . . . 24 & 25
Optional Features . . . . . . . . . . . . . . . . . . . . . . . 26 & 27
Special Valves
Universal Mount“P”. . . . . . . . . . . . . .28
Sandy Well Water. . . . . . . . . . . . . . . . .29
Gritty Coolant. . . . . . . . . . . . . . . . . 30 & 31
Ordering Information . . . . . . . . . . . . . . . . . . . 32 & 33
Terms & Conditions/Contact Info . . . . . . . . . . .34
3. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-VALVE SELECTION CHART
VALVE SELECTION CHART
33
Ordering Information - See Pages 32 & 33
For Optional Features - See Pages 26 & 27
Max . Temperature Up To 212°F Up To 400°F
Construction Bronze Stainless Steel
Valve Type D G/GR N/NR A/AR M/MR S/SR L/LR K/KR W/WR
Page 18 16&17 6&7 8&9 10&11 12&13 14&15 20&21 22&23
Max. Diff. Pressure 30PSI 50PSI 300PSI 500PSI 150PSI 180PSI 500PSI 500PSI 180PSI
Pipe Size Inches 3/8”-2” 1”-3” 1/2”-3/4” 1/2”-3” 3/8”-3/4” 1/2”-3” 1/2”-3” 1/2”-3” 1/2”-3”
Internal Port Size Full Full Reduced Full Reduced Full Full Full Full
Air
Brine
Gas
Oil
Solvents
Water
Vacuum
Steam
Cryogenic
Oxygen, Liquid
Oxygen, Gaseous
Corrosive
VALVE SELECTION CHART
(For Fluids/Gases Not Listed And For Special Applications, Consult Factory)
Use the chart above to determine suitable types
of Magnatrol valves for a given application.
Example: A normally closed 1/2”valve for use on 100 psi
steam, therearethreetypessuitableandthefinal selection
can only be made after referring to Bulletins 3006-M,
3006-S and 3006-W on pages 10, 12 and 22 respectively.
Maximum Differential Pressure:
When specifying a valve, the Maximum Differential
Pressure must be equal to or greater than the application.
Care should be taken not to “over specify” the valve by
choosing a valve with a Maximum Differential Pressure
that is excessively beyond the application.
If you are unsure please consult the factory.
2-Way and 3-Way • 1/4”Thru 6”
• Pressures to 10,000
• Fluid Temperatures up to 550°F
• Dirty / Viscous & Corrosive Fluids
• Bronze, 316SS, Monel, Alloy 20 & Hastelloy
• End connections: NPT, Flange, Union, SocketWeld, Butt Weld, Pipe Nipples
etc.
• Options: RemoteTrip with Manual or Automatic Reset and many others
3-Valve
Manifold for
CNG Refueling
High Pressure
Cartridge Valve
10,000 PSI 3-WayTripValve with 2 Position
Indicating Switches
and Manual Reset
4. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
44
BULLETIN 3006-COIL
SOLENOID COILS
CONTINUOUS DUTY COILS
ENCAPSULATED COIL
Reference should be made to the Bulletins to determine the availability
of a required valve for a specific power supply.
Consult the factory for information regarding voltage and frequencies not listed.
Valves for A.C. service can be converted for use on other A.C. voltages simply by changing the coil. Similarly D.C.
valves can be converted for other D.C. voltages. Consult factory regarding conversion from A.C. to D.C. or D.C. to A.C.
CURRENT CONSUMPTION:
Current values shown in the bulletins are for 120 volts, 60 hertz. For other voltages the current is inversely propor-
tional: For instance, if a given valve draws 0.5 amperes on 120 volts it would draw 0.25 amperes on 240 volts, or 0.125
amperes on 480 volts. Where power consumption is shown in D.C. watts, the values given should be divided by line
voltage to obtain the current in amperes. Power consumption for all valves is shown in the individual bulletins.
INSTALLATION:
The coil is a two wire device which may be controlled by either a single or double pole switch. The switch should
always be installed in the hot leg of 120 volt circuits. Where both legs are hot, such as 240 or 480 volt circuits, a double
pole switch is preferable, however, if a single pole switch is used, then the wiring should have top quality insulation
since even minute leakage currents may give rise to sticking problems. On motor hookup with step control starter, full
voltage should be supplied to coil immediately.
Note: Coil can be readily changed while valve is still under pressure.
Voltage 6 12 24 32 48 64 75 120 208 240 480 575
50, 60
• • • • • •Hertz AC
DC • • • • • • • * *
ELECTRICAL CHARACTERISTICS
Coils are stocked for the following voltages:
* Furnished with surge protecting capacitor75V DC for locomotive applications
CONSTRUCTION:
Continuous Duty Construction: Coils can be energized continuously without overheating or failure.
Wire Leads: 18”long 18 gauge wire standard (longer continuous leads available)
Encapsulated: Coils are encapsulated for temperature of intended service, providing excellent
resistance to shock, moisture, oil and chemicals
COIL CLASS:
GENERAL SERVICE - CLASS“B” HIGH TEMPERATURE - CLASS“H”
Maximum Fluid Maximum Ambient Maximum Fluid Maximum Ambient
Temperature Temperature Temperature Temperature
212° F ( ° C) 04° F (40° C) 00° F (206° C) 12° F (100° C)
5. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
55
BULLETIN 3006-CONSTRUCTION
VALVE CONSTRUCTION FEATURES
Valve Construction Features:
• 2-way straight thru globe design
• Bronze or Stainless Steel body w/ female NPT threads standard
• Stainless Steel available with 150# and 300# flanged ends
• Full port-internal pilot operated or direct acting
• Packless construction
• Continous duty coils for all voltages
• No differential pressure required to open
Inspect, clean or service all
internal parts of full port-internal
pilot operated or direct acting
solenoid valves while the valve
body remains in the pipeline
shortening costly down time and
increasing productivity.
MAGNATROL SOLENOID OPERATED VALVES are used to control the flow of liquids or gases, generally in
conjunction with automatic control apparatus such as thermostat, float switch, time switch, or flow meter.
Normally Closed Valve shown is
typical of Type A, 1/2”thru 1-1/4”
Easy In-Line Service
Coil
Enclosure
Conduit
Boss
Bonnet
Piston
Valve
Disc
Disc
Nut
Valve
Body
Pilot
Valve
Valve
Spring
Plunger
Bonnet
Ring
Coil
VALVE BODY
• Constructed of high
pressure cast bronze
or stainless steel in
a globe pattern with
screwed ends*
• Available in a full
range of sizes
BONNET
• A flanged metallic
tube encloses
the plunger and
hermetically
seals the top of
the valve
COIL
• Available Class“B”or
“H”insulation
• Designed for contin-
uous duty service
• Available in most AC
or DC voltages
HOUSING
• Construction: Malleable
or Cast Iron
• Designed for rugged
industrial use
• Self contained terminal
box with 1/2”NPS
conduit connection
• Available: NEMA 12, 4,
4X and Explosion Proof
PISTON
ASSEMBLY
• A sturdily constucted
stem assembly con-
sisting of a plunger
and stainless steel
pilot flexibly con-
nected to the piston
• Discs are available in
various materials
dictated by operat-
ing conditions
* Stainless Steel valves available
with flanged ends. Flanged Bronze
valves available through Magnatrol’s
Clark-Cooper Division (See bottom of
6. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-N
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“N” - NORMALLY CLOSED
1/2” TO 3/4”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
DIRECT ACTING - ORIFICE SIZES 3/32” TO 1/2”
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve,
when the coil is energized, the stem is lifted from its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Valve Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow ofWater, Oil, Air, Gas, Solvents, Brine,
Vacuum and any other fluids not reactive with construction
materials and free of sediment. Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
66
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
Valve
Port
Size
3/4
1/2
3/8
Optional“Soft Seat”Orifice Seal (for applications requiring tight seating)
Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids
25 3/8 18N22
50 1/4 18N42
75 3/16 18N52
25 0.4 1.2 18 6 6-1/4 5-3/8 2-3/4 2-3/4
100 5/32 18N82
150 1/8 18N62
225 3/32 18N72
50 3/8 33N22
75 5/16 33N32
100 1/4 33N42 45 0.8 2.4 23 10 7-1/8 6-3/8 3-1/2 2-3/4
150 3/16 33N52
300 1/8 33N62
15 1/2 18N13
25 0.4 1.3 18 7 6-1/2 5-5/8 2-3/4 2-7/8
35 5/16 18N33
30 1/2 33N13
45 0.8 2.5 23 10 7-3/8 6-1/2 3-1/2 2-7/8
75 5/16 33N33
DISCONTINUED -- USE 1/2” VALVE WITH BUSHING
7. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-NR
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“NR” - NORMALLY OPEN
1/2” TO 3/4”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
77
DIRECT ACTING - ORIFICE SIZES 3/32” TO 1/2”
OPERATION:
Valve closes when energized and opens when de-energized. In this direct acting valve,
when the coil is energized, the stem is pressed into its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 304 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Buna N
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow ofWater, Oil, Air, Gas, Solvents, Brine,
Vacuum and any other fluids not reactive with construction
materials and free of sediment. Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
Valve
Port
Size
3/4
1/2
3/8
23 3/8 18NR22
45 1/4 18NR42
70 3/16 18NR52
25 0.5 1.5 18 7 7 6-1/8 2-3/4 2-3/4
90 5/32 18NR82
135 1/8 18NR62
200 3/32 18NR72
45 3/8 33NR22
70 5/16 33NR32
90 1/4 33NR42 45 1.0 2.7 23 10 7-7/8 7-1/8 3-1/2 2-3/4
135 3/16 33NR52
270 1/8 33NR62
13 1/2 18NR13
25 0.5 1.6 18 7 7-1/4 6-3/8 2-3/4 2-7/8
32 5/16 18NR33
27 1/2 33NR13
45 1.0 2.8 23 10 8-1/8 7-1/4 3-1/2 2-7/8
70 5/16 33NR33
DISCONTINUED -- USE 1/2” VALVE WITH BUSHING
Optional“Soft Seat”Orifice Seal (for applications requiring tight seating)
Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids
8. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-A
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“A”FULL PORT - NORMALLY CLOSED
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve
opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon
de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure
to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
Vacuum
materials and free of sediment. Valve operates from zero to maximum
horizontal pipe with solenoid enclosure vertical and on top.
8
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Optional Features
(See pages 26 & 27)
†† Not available for
DC operation
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
1
1-1/4
1-1/2
2
2-1/2
3
Pipe
Size
Inches
Max
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
1/2
3/4
50
110
160
200
50
125
200
300
300
18A23
18A43
118A43
33A33
43A28
43A48
43A38
143A58
33A53
25
40
60
85
45
0.4
0.6
1.2
2.0
0.8
1.3
2.0
8.0
12.0
2.6
18
28
35
45
23
8
43
7-1/8
12-7/8
6
10-1/8
2-3/4
5-7/8
3-1/2
7-1/4
4-3/4
N/A
5-1/2
N/A
5
N/A
7
N/A
7-3/4
N/A
8
N/A
11
N/A
9-1/2
N/A
500 E133A63 65 1.2 3.9 33 17 8-1/8 7 4-1/8 3-1/2
50
110
160
200
300
18A24
18A44
118A44
33A34
33A54
25
40
45
0.4
0.6
0.8
1.5
2.3
2.8
18
28
23
10
14
7-7/8
8-7/8
6-5/8
7-1/2
2-3/4
4-1/8
4-1/8
4-1/8
500 E133A64 65 1.2 4.2 33 19 8-7/8 7-1/2 4-1/8 4-1/8
50
90
150
200
300
18A25
18A45
118A45
33A35
33A55
25
40
45
0.4
0.6
0.8
1.6
2.4
3.0
18
23
12
16
8-3/8
9-3/8
6-3/4
7-3/4
2-3/4
3-1/2
4-1/2
4-1/2
500 †† 40A65 60 1.2 6.2 N/A 20 10-3/8 8-3/4 4-1/2 4-1/2
50
115
160
200
300
35A26
35A46
135A46
41A36
41A56
45
65
60
0.8
1.2
1.2
3.2
4.8 33
6.7
23
35
20
24
10
11
8-1/8
9-1/8
4
4-1/2
4-7/8
4-7/8
500 141A66 85 2.0 10.0 45
50
100
200
300
44A29
44A49
44A39
144A59
60
85
1.2
2.0
8.8
13.0
35
45
56 13-3/4 10-1/2 6-5/8 8-3/8
50
100
150
200
300
36A27
36A47
136A47
42A37
42A57
45
65
60
0.8
1.2
1.2
3.5
5.0
7.4
23
33
35
31
36
11
12
8-3/4
9-3/4
5-3/8
5-3/4
6
6
500 142A67 85 2.0 11.0 45
110
200
300
500
18A42
18A32
18A52
E33A62
25
45
0.4
0.8
1.2
2.4
18
23
8
16
7
8
5-7/8
6-7/8
2-3/4
4-1/8
3-1/4
3-1/4
12 8-1/8 7 3-1/2 3-1/2
28
9. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-AR
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“AR”FULL PORT - NORMALLY OPEN
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
99
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger
presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build
above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the
pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at
zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacu-
um and any other fluids not reactive with construction materials and
free of sediment. Valve operates from zero to maximum differential
pressure indicated in table. Valve must be mounted in horizontal pipe
with solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
†† Not available for
DC operation
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
1
1-1/2
2
2-1/2
3
110
200
300
500
1/2
3/4
50
110
200
50
125
200
300
50
100
200
300
300
18AR42
18AR32
18AR52
E33AR62
18AR23
18AR43
33AR33
43AR28
43AR48
43AR38
143AR58
44AR29
44AR49
44AR39
144AR59
33AR53
25
45
25
45
60
85
60
85
0.5
1.0
0.5
1.0
1.7
3.5
1.7
3.5
1.5
2.7
1.6
2.9
8.0
13.0
8.8
13.0
18
23
18
23
35
45
35
45
8
16
9
45
57
13
8-1/8
9-3/8
8-1/4
13-1-2
14-3/8
9-1/4
7
8-1/4
7-1/8
10-3-4
11-1/8
8-1/8
2-3/4
4-1/8
2-3/4
5-7/8
6-5/8
3-1/2
3-1/4
3-1/4
3-1/2
7-1/4
8-3/8
3-1/2
4-3/4
N/A
5-1/2
N/A
5
N/A
7
N/A
7-3/4
N/A
8
N/A
11
N/A
9-1/2
N/A
500 E133AR63 65 1.5 4.3 33 18 9-1/2 8-3/8 4-1/8 3-1/2
50
110
200
300
18AR24
18AR44
33AR34
33AR54
25
45
0.5
1.0
1.8
3.0
18
23
11
14
9
10
7-3/4
8-5/8
2-3/4
3-1/2
4-1/8
4-1/8
500 E133AR64 65 1.5 4.5 33 19 10-1/4 8-7/8 4-1/8 4-1/8
50
90
200
300
18AR25
18AR45
33AR35
33AR55
25
45
0.5
1.0
1.9
3.2
18
23
13
17
9-3/4
10-3/4
8-1/8
9-1/8
2-3/4
3-1/2
4-1/2
4-1/2
500 †† 40AR65 60 1.7 6.2 N/A 21 11 9-3/8 4-1/2 4-1/2
50
115
200
300
35AR26
35AR46
41AR36
41AR56
45
60
1.0
1.7
3.8
6.5
23
35
21
25
11-3/8
11-5/8
9-1/2
9-3/4
4
4-1/2
4-7/8
4-7/8
500 141AR66 85 3.5 9.7 45
50
100
200
300
36AR27
36AR47
42AR37
42AR57
45
60
1.0
1.7
4.2
7.3
23
35
31 12-3/8 10-1/8 5-3/8 6
500 142AR67 85 3.5 11.0 45
36 12-5/8 10-3/8 5-3/4 6
1-1/4
10. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1010
BULLETIN 3006-M
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“M” - NORMALLY CLOSED
3/8” TO 3/4”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
150 PSI
DIRECT ACTING - ORIFICE SIZES 1/8” TO 1/2”
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve,
when the coil is energized, the stem is lifted from its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Valve Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of Steam, Hot Liquids, Hot Gases,
Cryogenics** and any other fluids not reactive with
construction materials and free of sediment. Cryogenic
fluids include Liquid Oxygen (-297°F), Liquid Argon
(-303°F) and Liquid Nitrogen (-320°F). Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
**Cleaning:
· Cryogenic valves are degreased and cleaned to keep them free of moisture.
· Oxygen valves are also“black light”tested.
INLET
25 3/8 10M21
50 1/4 10M41
75 3/16 10M51 25 0.4 1.1 18 6 6-1/4 5-1/2 2-7/8 2-5/8
100 5/32 10M81
150 1/8 10M61
50 3/8 25M21
75 5/16 25M31 45 0.8 2.3 23 10 7-1/8 6-3/8 3-1/2 2-5/8
100 1/4 25M41
150 3/16 25M51
25 3/8 10M22
50 1/4 10M42
75 3/16 10M52 25 0.4 1.2 18 6 6-1/4 5-1/2 2-7/8 2-3/4
100 5/32 10M82
150 1/8 10M62
50 3/8 25M22
75 5/16 25M32 45 0.8 2.4 23 10 7-1/8 6-3/8 3-1/2 2-3/4100 1/4 25M42
150 3/16 25M52
15 1/2 10M13 25 0.4 1.3 18 7 6-1/2 5-5/8 2-7/8 2-7/8
35 5/16 10M33
30 1/2 25M13
45 0.8 2.5 23 10 7-3/8 6-1/2 3-1/2 2-7/875 5/16 25M33
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
Valve
Port
Size
3/4
1/2
3/8
Optional“Soft Seat”Orifice Seal (for applications requiring tight seating)
Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids
11. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1111
BULLETIN 3006-MR
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“MR” - NORMALLY OPEN
3/8” TO 3/4”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
DIRECT ACTING - ORIFICE SIZES 1/8” TO 1/2”
OPERATION:
Valve closes when energized and opens when de-energized. In this direct acting valve,
when the coil is energized, the stem is pressed into its conical seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
* Poppet - 304 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Metal to Metal
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of Steam, Hot Liquids, Hot Gases,
Cryogenics** and any other fluids not reactive with
construction materials and free of sediment. Cryogenic
fluids include Liquid Oxygen (-297°F), Liquid Argon
(-303°F) and Liquid Nitrogen (-320°F). Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26& 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
150 PSI
**Cleaning:
· Cryogenic valves are degreased and cleaned to keep them free of moisture.
· Oxygen valves are also“black light”tested.
† UL Listed Valves - Consult Factory
23 3/8 † 10MR21
45 1/4 † 10MR41
70 3/16 † 10MR51 25 0.5 1.4 18 7 7 6-1/4 2-7/8 2-5/8
90 5/32 † 10MR81
135 1/8 † 10MR61
45 3/8 25MR21
70 5/16 25MR31 45 1.0 2.6 23 10 7-7/8 7-1/8 3-1/2 2-5/8
90 1/4 25MR41
135 3/16 25MR51
23 3/8 10MR22
45 1/4 10MR42
70 3/16 10MR52 25 0.5 1.5 18 7 7 6-1/4 2-7/8 2-3/4
90 5/32 10MR82
135 1/8 10MR62
45 3/8 25MR22
70 5/16 25MR32 45 1.0 2.7 23 10 7-7/8 7-1/8 3-1/2 2-3/4
90 1/4 25MR42
135 3/16 25MR52
13 1/2 10MR13 25 0.5 1.6 18 7 7-1/4 6-3/8 2-7/8 2-7/8
32 5/16 10MR33
27 1/2 25MR13 45 1.0 2.8 23 11 8-1/8 7-1/4 3-1/2 2-7/870 5/16 25MR33
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
Valve
Port
Size
3/4
1/2
3/8
Optional“Soft Seat”Orifice Seal (for applications requiring tight seating)
Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids
12. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1212
BULLETIN 3006-S
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“S”FULL PORT - NORMALLY CLOSED
1/2”TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the
pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by
the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed
passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
TO CONTROL THE FLOW OF STEAM. Steam must be free of
sediment. Valve operates from zero to maximum differential
pressure indicated in table. Valve must be mounted in
horizontal pipe with solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
200 PSI
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
† UL Listed Valves - Consult Factory †† Not available for DC operation
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
1
1-1/4
1-1/2
2
2-1/2
3
90
140
180
50
1/2
3/4 110
180
25
50
25
50
140
180
150
90
180
50
90
180
25
25
115
180
25
50
50
175
25
50
100
115
14S22
114S42
129S42
14S23
114S43
129S43
16S14
116S24
17S15
117S25
132S45
140S45
44S29
116S44
131S44
135S46
141S46
36S17
35S16
42S47
142S47
36S27
43S28
43S48
143S48
44S19
43S18
25
40
65
25
40
65
25
25
40
65
85
85
40
65
45
65
85
60
85
45
85
60
60
0.4
0.6
1.2
0.4
0.6
1.2
0.4
0.4
0.6
1.2
2.0
2.0
0.6
1.2
0.8
1.2
2.0
1.2
2.0
0.8
2.0
1.2
1.2
1.2
1.8
3.6
1.3
2.0
3.9
1.5
1.6
2.4
4.8
9.2
13.0
2.3
4.2
3.2
4.8
11.0
7.4
11.0
3.5
12.0
8.8
8.0
18
28
33
18
28
33
18
18
28
33
N/A
45
28
33
23
33
45
35
45
23
45
35
35
8
11
9
12
12
16
20
11
14
20
24
36
43
31
56
7
8
7-1/8
8-1/8
8-3/8
9-3/8
10-3/8
8
8-7/8
10
11
12
12-7/8
11
13-3/4
5-7/8
6-7/8
6
7
6-3/4
7-3/4
8-3/4
6-5/8
7-1/2
8-1/8
9-1/8
9-3/4
10-1/8
8-3/4
10-1/2
2-7/8
3-1/2
2-7/8
3-1/2
3-1/2
3-5/8
4-1/2
3-1/4
3-1/2
4
4-1/2
5-3/8
5-7/8
5-3/8
6-5/8
3-1/4
3-1/4
3-1/2
3-1/2
4-1/2
4-1/2
4-1/2
4-1/2
4-1/8
4-7/8
4-7/8
6
7-1/4
6
8-3/8
4-3/4
N/A
5-1/2
N/A
5
N/A
7
N/A
7-3/4
N/A
8
N/A
9-1/2
11
N/A
44S49
144S49
35S26
†
†
†
†
†
†
†
††
†
†
13. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1313
BULLETIN 3006-SR
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“SR”FULL PORT - NORMALLY OPEN
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the
plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit
pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice
is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom
spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron,1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Springs - Inconel and 302 Stainless Steel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
TO CONTROL THE FLOW OF STEAM. Steam must be free of
sediment. Valve operates from zero to maximum differential
pressure indicated in table. Valve must be mounted in
horizontal pipe with solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
200 PSI
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
† UL Listed Valves - Consult Factory †† Not available for DC operation
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
1
1-1/4
1-1/2
2
2-1/2
3
90
140
180
50
1/2
3/4 110
180
25
50
25
50
140
180
90
180
14SR22
114SR42
129SR42
14SR23
114SR43
129SR43
16SR14
116SR24
17SR15
117SR25
132SR45
116SR44
131SR44
25
40
65
25
40
65
25
40
25
40
65
85
65
0.5
0.8
1.5
0.5
0.8
1.5
0.5
0.8
0.5
0.8
1.5
3.5
1.5
1.5
2.4
4.2
1.6
2.6
4.3
1.8
2.9
1.9
3.0
4.8
9.0
4.5
18
28
33
18
28
33
18
28
18
28
33
N/A
33
8
11
9
13
11
13
17
20
15
8-1/8
9-1/8
7-1/8
9-1/4
9-1/8
9-3/4
10-3/4
11
10
7
8
6
8-1/8
7-3/4
8-1/8
9-1/8
9-3/8
8-5/8
2-7/8
3-1/2
2-7/8
3-1/2
3-1/4
3-1/2
3-5/8
4-1/2
3-1/2
3-1/4
3-1/4
3-1/2
3-1/2
4-1/8
4-1/2
4-1/2
4-1/2
4-1/8
4-3/4
N/A
5-1/2
N/A
5
N/A
7
N/A
25
50
140
180
35SR16
35SR26
135SR46
141SR46
45
60
85
1.0
1.5
3.5
3.8
5.7
9.7
23
33
45
21
25
11-3/8
11-5/8
9-1/2
9-3/4
4
4-1/2
4-7/8
4-7/8
7-3/4
N/A
25
50
115
180
36SR17
36SR27
42SR47
142SR47
45
60
85
1.0
1.7
3.5
4.2
7.3
11.0
23
35
45
31
36
12-3/8
12-5/8
10-1/8
10-3/8
5-3/8
5-3/8
6
6
8
N/A
25
50
115
175
43SR18
43SR28
43SR48
143SR48
60
85
1.7
3.5
8.0
12.0
35
45
45 13-1/2 10-3/4 5-7/8 7-1/4
11
N/A
25
50
100
150
44SR19
44SR29
44SR49
144SR49
60
85
1.7
3.5
8.8
13.0
35
45
57 14-3/8 11-1/8 6-5/8 8-3/8 9-1/2
140SR45
†
†
†
†
†
†
†
††
†
†
14. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1414
BULLETIN 3006-L
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“L”FULL PORT - NORMALLY CLOSED
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, reliev-
ing the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a
spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPT conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any
other fluids not reactive with construction materials and free of sediment.
Cryogenic fluids include Liquid Oxygen (-297°F), Liquid Argon (-303°F) and
Liquid Nitrogen (-320°F). Valve operates from zero to maximum differential
pressure indicated in table. Valve must be mounted in horizontal pipe with
solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
†† Not available for DC operation
** CLEANING
• Cryogenic valves are
degreased & cleaned
to keep them free of
moisture.
• Oxygen valves are also
“black light”tested.
FOR
STEAM APPLICATIONS
SEE BULLETIN 3006-S
Page 12
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
1
1-1/4
1-1/2
2
2-1/2
3
110
200
300
500
1/2
3/4
14L42
14L32
29L52
E29L62
25
45
45
0.4
0.8
0.8
1.2
2.4
2.4
18
23
23
8
11
16
7
8
8
5-7/8
6-7/8
6-7/8
2-7/8
3-1/2
4
3-1/4
3-1/4
3-1/4
4-3/4
N/A
5-1/2
N/A
5
N/A
7
N/A
7-3/4
N/A
11
N/A
N/A
9-1/2
50
110
200
300
14L23
14L43
29L33
129L53
25
45
65
0.4
0.8
1.2
1.3
2.6
3.9
18
23
33
9
12
7-1/8
8-1/8
6
7
2-7/8
3-1/2
3-1/2
3-1/2
500 E129L63 65 1.2 3.9 33 17 8-1/8 7 4 3-1/2
50
110
200
300
16L24
16L44
31L34
131L54
25
45
65
0.4
0.8
1.2
1.5
2.8
4.2
18
23
33
11
14
8
8-7/8
6-5/8
7-1/2
3-1/4
3-1/2
4-1/8
4-1/8
500 E131L64 65 1.2 4.2 33 19 8-7/8 7-1/2 4 4-1/8
50
90
200
300
17L25
17L45
32L35
132L55
25
45
65
0.4
0.8
1.2
1.6
3.0
4.5
18
23
33
12
16
8-3/8
9-3/8
6-3/4
7-3/4
3-1/2
3-5/8
4-1/2
4-1/2
500 †† 140L65 85 2.0 9.2 N/A 20 10-3/8 8-3/4 4-1/2 4-1/2
50
115
200
300
35L26
35L46
41L36
141L56
45
60
85
0.8
1.2
2.0
3.2
6.7
10.0
23
35
45
20
24
10
11
8-1/8
9-1/8
4
4-1/2
4-7/8
4-7/8
500 141L66
50
100
200
300
36L27
36L47
42L37
42L57
45
60
0.8
1.2
3.5
7.4
23
35
31
36
11
12
8-3/4
9-3/4
5-3/8
5-3/8
6
6
500 142L67 85 2.0 11.0 45
50
125
200
300
43L28
43L48
43L38
143L58
60
60
85
1.2
1.2
2.0
8.0
8.0
12.0
35
35
45
43 12-7/8 10-1/8 5-7/8 7-1/4
50
100
200
300 144L59
60
85
1.2
2.0
8.8
13.0
35
45
56 13-3/4 10-1/2 6-5/8 8-3/8
8
N/A
44L29
44L49
44L39
15. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1515
BULLETIN 3006-LR
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“LR”FULL PORT - NORMALLY OPEN
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the
poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seal
it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave
its seat. The bottom spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPT conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Springs - Inconel and 302 Stainless Steel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18”leads
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
†† Not available for DC operation
** CLEANING
• Cryogenic valves are
degreased & cleaned
to keep them free of
moisture.
• Oxygen valves are also
“black light”tested.
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
FOR
STEAM APPLICATIONS
SEE BULLETIN 3006-SR
Page 13
APPLICATION:
To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other
fluids not reactive with construction materials and free of sediment. Cryogenic
fluids include Liquid Oxygen (-297°F), Liquid Argon (-303°F) and Liquid Nitrogen
(-320°F). Valve operates from zero to maximum differential pressure indicated in
table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical
and on top.
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D D(Flanged)
150#
1
1-1/4
1-1/2
2
2-1/2
3
110
200
300
500
1/2
3/4
14LR42
14LR32
29LR52
E29LR62
25
45
45
0.5
1.0
1.0
1.5
2.7
2.7
18
23
23
18
11
16
8-1/8
9-1/8
9-1/8
7
8
8
2-7/8
3-1/2
4
3-1/4
3-1/4
3-1/4
4-3/4
N/A
5-1/2
N/A
5
N/A
7
N/A
7-3/4
N/A
11
N/A
N/A
9-1/2
50
110
200
300
14LR23
14LR43
29LR33
129LR53
25
45
65
0.5
1.0
1.5
1.6
2.9
4.3
18
23
33
9
13
8-1/4
9-1/4
7-1/8
8-1/8
2-7/8
3-1/2
3-1/2
3-1/2
500 E129LR63 65 1.5 4.3 33 18 9-1/4 8-1/8 4 3-1/2
50
110
200
300
16LR24
16LR44
31LR34
131LR54
25
45
65
0.5
1.0
1.5
1.8
3.0
4.5
18
23
33
11
15
9-1/8
10
7-3/4
8-5/8
3-1/4
3-1/2
4-1/8
4-1/8
500 E131LR64 65 1.5 4.5 33 20 10 8-5/8 4 4-1/8
50
90
200
300
17LR25
17LR45
32LR35
132LR55
25
45
65
0.5
1.0
1.5
1.9
3.2
4.8
18
23
33
13
17
9-3/4
10-3/4
8-1/8
9-1/8
3-1/2
3-5/8
4-1/2
4-1/2
500 †† 140LR65
50
115
200
300
35LR26
35LR46
41LR36
141LR56
45
60
85
1.0
1.7
3.5
3.8
6.5
9.7
23
35
45
21
25
11-3/8
11-5/8
9-3/8
9-3/4
4
4-1/2
4-7/8
4-7/8
500 141LR66
50
100
200
300
36LR27
36LR47
42LR37
42LR57
45
60
1.0
1.7
4.2
7.3
23
35
31
36
12-3/8
12-5/8
10-1/8
10-3/8
5-3/8
5-3/8
6
6
500 142LR67 85 3.5 11.0 45
50
125
200
300
43LR28
43LR48
43LR38
143LR58
60
85
1.7
3.5
8.0
12.0
35
45
45 13-1/2 10-3/4 5-7/8 7-1/4
50
100
200
300
44LR29
44LR49
44LR39
144LR59
60
85
1.7
3.5
8.8
13.0
35
45
57 14-3/8 11-1/8 6-5/8 8-3/8
8
N/A
85 3.5 9.0 N/A 20 11 9-3/8 4-1/2 4-1/2
16. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1616
BULLETIN 3006-G
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“G”FULL PORT - NORMALLY CLOSED
1” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
150 PSI
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the
pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by
the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed
passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit
conn.
*Plunger - 430 Stainless Steel
*Pilot Valve Stem - 303 Stainless Steel
*Pilot Valve Disc Holder - Brass
*Pilot Valve Seal - Buna N (Viton available)
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow of Water, Air, Gas, Solvents, Vacuum
and any other fluids not reactive with construction materials
and free of sediment. Buna N seating of the pilot and main
orifices make the valves ideal for TIGHT SEATING, LOW
PRESSURE and LOW FLOW conditions. Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
† UL Listed Valves - Consult Factory
† 18G24
118G24
133G24
† 18G25
118G25
133G25
† 18G26
118G26
133G26
33G27
133G27
233G27
43G28
143G28
44G29
144G29
25
40
65
25
40
65
25
40
65
45
65
80
60
85
60
85
1
1-1/4
1-1/2
2
2-1/2
3
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
20
30
50
20
30
50
15
25
35
18
30
50
25
35
25
35
0.4
0.6
1.2
0.4
0.6
1.2
0.4
0.6
1.2
0.8
1.2
1.8
1.2
2.0
1.2
2.0
1.4
2.3
4.0
1.5
2.4
4.1
1.7
2.5
4.2
3.4
4.2
9.0
7.8
12.0
8.6
13.0
18
28
33
18
28
33
18
28
33
23
33
40
35
45
35
45
7-1/2
7-1/2
8-1/2
8
8
8-7/8
8-1/8
8-1/8
9-1/8
9-7/8
9-7/8
9-7/8
12-1/8
12-1/8
13
13
6-1/8
6-1/8
7-1/8
6-3/8
6-3/8
7-3/8
6-1/2
6-1/2
7-1/2
7-7/8
7-7/8
7-7/8
8-5/8
9-5/8
10
10
2-3/4
2-3/4
3-1/2
2-7/8
2-7/8
3-1/2
3-1/8
3-1/8
3-1/2
3-3/4
3-3/4
3-3/4
5-7/8
5-7/8
6-5/8
6-5/8
4-1/8
4-1/8
4-1/8
4-3/8
4-3/8
4-3/8
4-3/4
4-3/4
4-3/4
5-3/4
5-3/4
5-3/4
7-7/8
7-7/8
8
8
6-3/4
7
7-3/4
10
11
13-5/16
9
9
13
10
10
14
12
12
16
20
20
20
38
38
46
46
17. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1717
BULLETIN 3006-GR
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“GR”FULL PORT - NORMALLY OPEN
1” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the
plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit
pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice
is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom
spring allows the valve to operate at zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit
conn.
*Plunger - 430 Stainless Steel
*Pilot Valve Stem - 303 Stainless Steel
*Pilot Valve Disc Holder - Brass
*Pilot Valve Seal - Buna N (Viton available)
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
APPLICATION:
To control the flow of Water, Air, Gas, Solvents, Vacuum
and any other fluids not reactive with construction materials
and free of sediment. Buna N seating of the pilot and main
orifices make the valves ideal for TIGHT SEATING, LOW
PRESSURE and LOW FLOW conditions. Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
150 PSI
† UL Listed Valves - Consult Factory
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
† 18GR24
33GR24
† 18GR25
33GR25
† 18GR26
33GR26
33GR27
133GR27
43GR28
44GR29
25
45
25
45
25
45
45
65
60
60
1
1-1/4
1-1/2
2
2-1/2
3
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
20
35
20
35
15
25
18
30
25
25
0.5
1.0
0.5
1.0
0.5
1.0
1.0
1.5
1.7
1.7
1.5
3.0
1.9
3.2
2.0
3.8
4.2
4.5
8.0
8.8
18
23
18
23
18
23
23
33
35
35
8-5/8
9-5/8
9-3/8
10-1/4
9-1/2
10-1/2
11-1/4
11-1/4
12-3/4
13-5/8
7-1/4
8-1/4
7-3/4
8-3/4
7-7/8
8-7/8
9-1/4
9-1/4
10-1/4
10-5/8
2-3/4
2-3/4
2-7/8
3-1/2
3-1/8
3-1/2
3-3/4
3-3/4
5-7/8
6-5/8
4-1/8
4-1/8
4-3/8
4-3/8
4-3/4
4-3/4
5-3/4
5-3/4
7-7/8
8
6-3/4
7
7-3/4
10
11
13-5/16
9
13
10
14
12
16
21
21
39
47
18. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1818
BULLETIN 3006-D
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“D”FULL PORT - NORMALLY CLOSED
3/8” TO 2”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
150 PSI
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve the
disc holder assembly is lifted from its seat by the plunger.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Disc Holder - Brass
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow of Water, Air, Gas, Solvents, Vacuum
and any other fluids not reactive with construction
materials and free of sediment. Buna N seating of the
main orifice make the valves ideal for TIGHT SEATING, LOW
PRESSURE and LOW FLOW conditions. Valve operates from
zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
† UL Listed Valves - Consult Factory
n..
)
18D11
33D11
18D12
33D12
18D13
33D13
18D14
33D14
25
45
25
45
25
45
25
45
3/8
1/2
3/4
1
1-1/2
2
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs.
Dimension In Inches
A B C D
D(Flanged)
150#
15
30
10
20
4
7.5
2
3.5
0.4
0.8
0.4
0.8
0.4
0.8
0.4
0.8
1.0
2.3
1.1
2.4
1.2
2.5
1.4
2.7
18
23
18
23
18
23
23
33
6-1/4
7-1/8
6-1/4
7-1/4
6-7/8
7-3/4
7-1/2
8-1/2
5-3/8
6-3/8
5-1/2
6-3/8
5-3/4
6-3/4
6-1/8
7-1/8
2-3/4
3-1/2
2-3/4
3-1/2
2-7/8
2-7/8
3-1/8
3-1/8
3-1/2
3-1/2
4-1/8
4-1/8
N/A
4-3/4
5-1/2
6-3/4
7
10
7
10
8
12
9
13
18D15
33D15
25
45
1.3
2.3
0.4
0.8
1.5
2.8
18
23
8
8-7/8
6-3/8
7-3/8
2-7/8
3-1/2
4-3/8
4-3/8 710
14
18D16
† 33D16
25
45
0.8
1.5
0.4
0.8
1.7
3.0
18
23
8-1/8
9-1/8
6-1/2
7-1/2
3-1/8
3-1/2
4-3/4
4-3/4 7-3/4
12
15
33D17
† 133D17
45
65
0.8
1.2
0.8
1.2
3.4
4.2
23
33
9-7/8
9-7/8
7-7/8
7-7/8
3-3/4
3-3/4
5-3/4
5-3/4 10
19
19
1-1/4
2-3/4
3-1/2
2-3/4
3-1/2
19. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
1919
BULLETIN 3006-STN-Y
STRAINERS
Bronze • Stainless Steel
APPLICATION:
The presence of foreign particles in an automatic valve may seriously affect its
dependability. The installation of a strainer close to the inlet side of the valve is
the best means of preventing the entrance of pipe chips, scale, rust, pipe dope,
welding slag or sediment into the valve, provided the screen is periodically
removed for cleaning.
CONSTRUCTION:
Strainer bodies have screwed ends. Screens are stainless steel with opening
sizes as listed in tables below. Other sizes can be furnished upon request. Liberal
straining area provides for fluid passage at minimum pressure drop. Screens
are easily removed for cleaning. Strainers are furnished with NPT blow-off
connections unplugged. See charts below for blow-off sizes (C Dim.)
CLEANING FOR CRYOGENIC & OXYGEN SERVICE:
• Strainers for Cryogenic applications are degreased and cleaned to keep them
free of moisture.
• Strainers for Oxygen service are degreased and cleaned then“black light”
tested.
BRONZE 300 PSI @ 400°F 600 PSI @ 100°F
STAINLESS STEEL 845 PSI @ 750°F 1,440 PSI @ 100°F
MATERIAL STEAM LIQUIDS
PRESSURE TEMPERATURE RATINGS
BRONZE 1/4” TO 3”PIPE SIZE
1/4 BR 0 3/4 2-3/4 2-1/4 1/4
3/8 BR 1 3/4 2-3/4 2-1/4 1/4
1/2 BR 2 3/4 2-3/4 2-1/4 1/4
3/4 BR 3 1-1/2 3 2-9/16 3/8
1 BR 4 2-1/4 3-3/4 2-3/4 3/8
1-1/4 BR 5 3-1/4 4-7/16 3-5/8 3/4
1-1/2 BR 6 4-1/2 4-15/16 3-7/8 3/4
2 BR 7 7 6-1/8 5-1/16 1
2-1/2 BR 8 12-1/2 8-1/4 6 1-1/4
3 BR 9 18 9 6-3/4 1-1/2
Pipe
Size
Inches
Type No.
Ship
Wt.
Lbs. A
Dimensions In Inches
B C
Screen Size
60 Mesh
0.009
Openings
0.16 Diameter
Perforations
Lined With
30 Mesh
STAINLESS STEEL 1/2” TO 2”PIPE SIZE
1/2 SS 2 1-1/2 3 2-3/8 1/4
3/4 SS 3 2-1/4 3-3/4 2-13/16 3/8
1 SS 4 3-1/4 4-5/8 3-1/8 3/8
1-1/2 SS 6 6-3/4 5-5/8 4-3/4 3/4
2 SS 7 11-1/2 7 6 1
Pipe
Size
Inches
Type No.
Ship
Wt.
Lbs. A
Dimensions In Inches
B C
Screen Size
60 Mesh
0.009
Openings
0.16 Diameter
Perforations
Lined w/30 Mesh
20. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-J
STAINLESS STEEL SOLENOID VALVES
Dependable • Packless
TYPE“J” - NORMALLY CLOSED
3/8” TO 1/2”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
OPERATION:
Valve opens when energized and closes when de-energized. In this direct acting valve, when the
coil is energized, the stem is lifted from its conical seat by the plunger.
CONSTRUCTION: (*Wetted parts)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron,1/2 ”NPT conduit conn.
*Plunger - 430 Stainless Steel
*Valve Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Metal to Metal
*AC Shading Coil - Silver
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of Steam, Hot Liquids, Hot Gases,
Cryogenics and any other fluids not reactive with
construction materials and free of sidement. Cryogenic
fluids include liquid oxygen (-297ºF), liquid argon(-303ºF)
and liquid nitrogen (-320ºF). Valve operates from zero to
maximum differential pressure indicated in table. Valve
must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
2020
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS AND
ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
** CLEANING
• Cryogenic valves are
degreased & cleaned
to keep them free of
moisture.
• Oxygen valves are also
“black light”tested.
DIRECT ACTING - ORIFICE SIZES 1/8”TO 3/8”
Pipe
Size
Inches
Max.
Diff.
PSI
Valve
Port
Size
Type No.
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C
1/2
3/8
D
Watts
AC
25 3/8 10J21
25 0.4 1.1 18 6 6-1/4 5-1/2 2-7/8 2-3/475 3/16 10J51
150 1/8 10J61
50 3/8 25J21
45 0.8 2.3 23 10 7-1/8 6-3/8 3-1/2 2-3/4150 3/16 25J51
300 1/8 25J61
25 3/8 10J22
25 0.4 1.2 18 6 6-1/4 5-1/2 2-7/8 2-3/475 3/16 10J52
150 1/8 10J62
50 3/8 25J22
45 0.8 2.4 23 10 7-1/8 6-3/8 3-1/2 2-3/4150 3/16 25J52
300 1/8 25J62
Optional“Soft Seat”Orifice Seal:
(for applications requiring tight seating):
• Viton - Suitable for Fuel Oils, Gaseous Oxygen and other
compatible fluids
21. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
2121
BULLETIN 3006-JR
STAINLESS STEEL SOLENOID VALVES
Dependable • Packless
TYPE“JR” - NORMALLY OPEN
3/8” TO 1/2”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
FOR OPTIONS AND
ACCESSORIES
SEE PAGES 26 & 27
OPERATION:
Valve closes when energized and opens when de-energized. In this direct acting valve, when the
coil is energized, the stem is pressed into its conical seat by the plunger.
CONSTRUCTION: (*Wetted parts)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
Coil Enclosure - Malleable Iron,1/2 ”NPT conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 304 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Metal to Metal
*AC Shading Coil - Silver
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of Steam, Hot Liquids, Hot Gases,
Cryogenics and any other fluids not reactive with
construction materials and free of sidement. Cryogenic
fluids include liquid oxygen (-297ºF), liquid argon (-303ºF)
and liquid nitrogen (-320ºF). Valve operates from zero to
maximum differential pressure indicated in table. Valve
mustbemountedinhorizontalpipewithsolenoidenclosure
vertical and on top.
DIRECT ACTING - ORIFICE SIZES 1/8”TO 3/8”
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
** CLEANING
• Cryogenic valves are
degreased & cleaned
to keep them free of
moisture.
• Oxygen valves are also
“black light”tested.
Pipe
Size
Inches
Max.
Diff.
PSI
Valve
Port
Size
Type No.
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C
1/2
3/8
D
Watts
AC
23 3/8 10JR21
25 0.5 1.4 18 7 7 6-1/4 2-7/8 2-3/470 3/16 10JR51
135 1/8 10JR61
45 3/8 25JR21
45 1.0 2.6 23 10 7-7/8 7-1/8 3-1/2 2-3/4135 3/16 25JR51
300 1/8 25JR61
23 3/8 10JR22
25 0.5 1.5 18 7 7 6-1/4 2-7/8 2-3/470 3/16 10JR52
135 1/8 10JR62
45 3/8 25JR22
45 1.0 2.7 23 10 7-7/8 7-1/8 3-1/2 2-3/4135 3/16 25JR52
300 1/8 25JR62
Optional“Soft Seat”Orifice Seal:
(for applications requiring tight seating):
• Viton - Suitable for Fuel Oils, Gaseous Oxygen and other
compatible fluids
22. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
BULLETIN 3006-K
STAINLESS STEEL SOLENOID VALVES
Dependable • Packless
TYPE“K”FULL PORT - NORMALLY CLOSED
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the
pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by
the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed
passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION:
(*Wetted parts - No Copper Bearing Alloys in contact with fluid)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
(For Flanged Ends see Options page 24)
*Piston - 303 Stainless Steel
Coil Enclosure - Malleable or Cast Iron,1/2 ”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Silver
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of Corrosive Fluids, Deionized Water, Conden-
sate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable
Liquids. Cryogenic fluids include liquid oxygen (-297ºF), liquid argon
(-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to
maximum differential pressure indicated in table. Valve must be mounted
in horizontal pipe with solenoid enclosure vertical and on top.
2222
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
Shipping Weights above apply to Threaded Ends Only (except 3”which are Flanged Only)
For Flanged Ends contact factory for complete weight and dimensions
3”STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY
** CLEANING
• Cryogenic valves are
degreased & cleaned
to keep them free of
moisture.
• Oxygen valves are also
“black light”tested.
FOR
STEAM APPLICATIONS
SEE BULLETIN 3006-W
Page 22
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
NPT
2
1-1/2
3/4
1/2
1
D (Flanged)
150# 300#
3
110 14K42 25 0.4 1.2 18 7 7 5-7/8 2-7/8200 14K32 6 6-1/2
300 29K52 45 0.8 2.4 23 10 8 6-7/8 3-1/2
3-1/4
500 E29K62 15 4
110 14K43 25 0.4 1.3 18 8 7-1/8 6 2-7/8
200 29K33 45 0.8 2.6 23 11 3-1/2 3-1/2 6 6-1/2
300 129K53 65 1.2 3.9 33 8-1/8 7
500 E129K63 16 4
110 16K44 25 0.4 1.5 18 10 8 6-5/8 3-1/4
200 31K34 45 0.8 2.8 23 13 3-1/2 4-1/8 6-1/2 7-1/2
300 131K54 65 1.2 4.2 33 8-7/8 7-1/2
500 E131K64 18 4
115 35K46 45 0.8 3.2 23 17 10 8-1/8 4
200 41K36 60 1.2 6.7 35 6-1/2 7-1/2
300 141K56 85 2.0 10.0 45 21 11 9-1/8 4-1/2
4-7/8
500 141K66
100 36K47 45 0.8 3.5 23 27 11 8-3/4
200 42K37 60 1.2 7.4 35 5-3/8 6 8 9
300 42K57 32 12 9-3/4
500 142K67 85 2.0 11.0 45
100 44K49F1 60 1.2 8.8 35 68
13-3/4 10-1/2 6-5/8 N/A
9-1/2 N/A
200 44K39F1
300 144K59F3 85 2.0 13.0 45 81 N/A 12-1/2
23. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
2323
BULLETIN 3006-KR
STAINLESS STEEL SOLENOID VALVES
Dependable • Packless
TYPE“KR”FULL PORT - NORMALLY OPEN
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
FOR OPTIONS & ACCESSORIES SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the
plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit
pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is
opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring
allows the valve to operate at zero pressure drop.
CONSTRUCTION:
(*Wetted parts - No Copper Bearing Alloys in contact with fluid)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
(For Flanged Ends see Options page 24)
*Piston - 303 Stainless Steel
Coil Enclosure - Malleable or Cast Iron, 1/2 ”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Silver
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
TocontroltheflowofCorrosiveFluids,DeionizedWater,Condensate,Ammonias,
Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids
include liquid oxygen (-297ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF).
Valve operates from zero to maximum differential pressure indicated in table. Valve
must be mounted in horizontal pipe with solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
** CLEANING
• Cryogenic valves are
degreased & cleaned
to keep them free of
moisture.
• Oxygen valves are also
“black light”tested.
FOR
STEAM APPLICATIONS
SEE BULLETIN 3006-WR
Page 23
110 14KR42 25 0.5 1.5 18 7 8-1/8 7 2-7/8
200 14KR32 6 6-1/2
300 29KR52 45 1.0 2.7 23 10 9-1/8 8 3-1/2
3-1/4
500 E29KR62 15 4
110 14KR43 25 0.5 1.6 18 8 8-1/4 7-1/8 2-7/8
200 29KR33 45 1.0 2.9 23 12 3-1/2 3-1/2 6 6-1/2
300 129KR53 65 1.5 4.3 33 9-1/4 8-1/8
500 E129KR63 17 4
110 16KR44 25 0.5 1.8 18 10 9-1/8 7-3/4 3-1/4
200 31KR34 45 1.0 3.0 23 14 3-1/2 4-1/8 6-1/2 7-1/2
300 131KR54 65 1.5 4.5 33 10 8-5/8
500 E131KR64 20 4
115 35KR46 45 1.0 3.8 23 18 11-3/8 9-1/2 4
200 41KR36 60 1.7 6.5 35 6-1/2 7-1/2
300 141KR56 85 3.5 9.7 45 22 11-5/8 9-3/4 4-1/2
4-7/8
500 141KR66
100 36KR47 45 1.0 4.2 23 27 12-3/8 10-1/8
200 42KR37 60 1.7 7.3 35 5-3/8 6 8 9
300 42KR57 32 12-5/8 10-3/8
500 142KR67 85 3.5 11.0 45
100 44KR49F1 60 1.7 8.8 35 69
14-3/8 11-1/8 6-5/8 N/A
9-1/2 N/A
200 44KR39F1
300 144KR59F3 85 3.5 13.0 45 82 N/A 12-1/2
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
2
1-1/2
3/4
1/2
1
D (Flanged)
150# 300#
3
Shipping Weights above apply to Threaded Ends Only (except 3”which are Flanged Only)
For Flanged Ends contact factory for complete weight and dimensions
3”STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY
24. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
2424
BULLETIN 3006-W
STAINLESS STEEL SOLENOID VALVES
Dependable • Packless
TYPE“W”FULL PORT - NORMALLY CLOSED
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the
pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by
the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed
passageway to permit pressure to build above the piston and seat it.
CONSTRUCTION:
(*Wetted parts - No Copper Bearing Alloys in contact with fluid)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
(For Flanged Ends see Options page 24)
*Piston - 303 Stainless Steel
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Silver
*Stem Pin - Inconel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of STEAM. Steam must be free of sediment. Valve
operates from zero to maximum differential pressure indicated in table.
Valve must be mounted in horizontal pipe with solenoid enclosure vertical
and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
200 PSI
90 14W22 25 0.4 1.2 18 7 7 5-7/8 2-7/8
140 114W42 40 0.6 1.8 28 3-1/4 6
180 129W42 65 1.2 3.6 33 10 8 6-7/8 3-1/2
50 14W23 25 0.4 1.3 18 8 7-1/8 6 2-7/8
110 114W43 40 0.6 2.0 28 3-1/2 6
180 129W43 65 1.2 3.9 33 11 8-1/8 7 3-1/2
25 16W14 25 0.4 1.5 18
50 116W24 40 0.6 2.3 28 10 8 6-5/8 3-1/4 4-1/8 6-1/2
90 116W44
180 131W44 65 1.2 4.2 33 13 8-7/8 7-1/2 3-1/2
25 35W16
45 0.8 3.2 2350 35W26 17 10 8-1/8 4 4-7/8 6-1/2
90 135W46 65 1.2 4.8 33
180 141W46 85 2.0 10.0 45 21 11 9-1/8 4-1/2
25 36W17
45 0.8 3.5 23 27 11 8-3/450 36W27 5-3/8 6 8
115 42W47 60 1.2 7.4 35
32 12 9-3/4180 142W47 85 2.0 11.0 45
25 44W19F1
50 44W29F1 60 1.2 8.8 35 68 13-3/4 10-1/2 6-5/8 N/A 9-1/2
100 44W49F1
150 144W49F1 85 2.0 13.0 45
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
2
1-1/2
3/4
1/2
1
D (Flanged)
150#
3
Shipping Weights above apply to Threaded Ends Only (except 3”which are Flanged Only)
For Flanged Ends contact factory for complete weight and dimensions
3”STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY
25. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
2525
BULLETIN 3006-WR
STAINLESS STEEL SOLENOID VALVES
Dependable • Packless
TYPE“WR”FULL PORT - NORMALLY OPEN
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
FOR OPTIONS & ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
400° F
MAX. STATIC PRESSURE
200 PSI
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the
plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit
pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is
opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring
allows the valve to operate at zero pressure drop.
CONSTRUCTION:
(*Wetted parts - No Copper Bearing Alloys in contact with fluid)
*Valve Body - 304 Stainless Steel Globe Pattern - NPT ends
(For Flanged Ends see Options page 24)
*Piston - 303 Stainless Steel
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel
*Body Seal - Non Asbestos Gasket
*Orifice Seal - Glass Filled Teflon
*AC Shading Coil - Silver
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class H, 18”leads
APPLICATION:
To control the flow of STEAM. Steam must be free of sediment. Valve
operates from zero to maximum differential pressure indicated in table. Valve
must be mounted in horizontal pipe with solenoid enclosure vertical and on
top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
90 14WR22 25 0.5 1.5 18 7 8-1/8 7 2-7/8
140 114WR42 40 0.8 2.4 28 3-1/4 6
180 129WR42 65 1.5 4.2 33 10 9-1/8 8 3-1/2
50 14WR23 25 0.5 1.6 18 8 8-1/4 7-1/8 2-7/8
110 114WR43 40 0.8 2.6 28 3-1/2 6
180 129WR43 65 1.5 4.3 33 12 9-1/4 8-1/8 3-1/2
25 16WR14 25 0.5 1.8 18
50 116WR24 40 0.8 2.9 28 10 9-1/8 7-3/4 3-1/4 4-1/8 6-1/2
90 116WR44
180 131WR44 65 1.5 4.5 33 14 10 8-5/8 3-1/2
25 35WR16
45 1.0 3.8 2350 35WR26 18 11-3/8 9-1/2 4 4-7/8 6-1/2
90 135WR46 65 1.5 5.7 33
180 141WR46 85 3.5 9.7 45 22 11-5/8 9-3/4 4-1/2
25 36WR17
45 1.0 4.2 23 27 12-3/8 10-1/850 36WR27 5-3/8 6 8
115 42WR47 60 1.7 7.3 35
32 12-5/8 10-3/8180 142WR47 85 3.5 11.0 45
25 44WR19F1
50 44WR29F1 60 1.7 8.8 35 69 14-3/8 11-1/8 6-5/8 N/A 9-1/2
100 44WR49F1
150 144WR49F1 85 3.5 13.0 45
Pipe
Size
Inches
Max.
Diff.
PSI
Type No. Watts
AC
Amps
Hold
120-60
Amps
Inrush
120-60
Watts
DC
Ship
Wt.
Lbs. A
Dimensions In Inches
B C D
2
1-1/2
3/4
1/2
1
D (Flanged)
150#
3
Shipping Weights above apply to Threaded Ends Only (except 3”which are Flanged Only)
For Flanged Ends contact factory for complete weight and dimensions
3”STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY
26. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
2626
BULLETIN 3006-OPT
OPTIONAL FEATURES
For Dependable • Packless Solenoid Valves
See Individual Options For Availability For Use With Specific Valve Types
(Designated by Prefix“PT”)
Type D, G & GR Valves can be
furnished with 1/8”tapped hole for
pilot connection or pressure gauge.
PILOT TAP
(Designated by Suffix“DN”)
Provides 3 prong connector for easy
power connect / disconnect.
Not available for Explosion-Proof.
DIN CONNECTOR
(Normally Closed valves only)
(Designated by Prefix“MO”)
Enables manual opening of solenoid
valve during power failure or to
override automatic controls.
MANUAL OVERRIDE
(Designated by Prefix“DP”)
Furnished for clean liquids to reduce
water hammer effect sometimes
encountered in long pipe runs by
slowing valve closing.
DASHPOT
(Designated by Prefix“MS”)
3/8”-16 thread can be furnished in
bottom of body to facilitate mount-
ing on bracket. (Not available on 2”,
2-1/2”and 3”)
MOUNTING STUD
(Normally Closed valves only)
(Designated by Prefix“LV”)
Enables rapid opening of
solenoid valve. Can be chain
operated for use at inaccessible
locations.
LEVER
(Normally Closed, NR & MR valves,
only) (Designated by Prefix“FC”)
Provides a manual method of
reducing or throttling the flow.
FLOW CONTROL
(Normally Closed, NR & MR valves,
only)
(Designated by Prefix“DR”) - 1/4”
NPT plug supplied in bottom of
valve to facilitate draining of liquid
DRAIN
BOTTOM MOUNTED OPTIONS Note: OnlyOneBottomMountOptionCanBeInstalledOnEachValve
“HUM FREE”: (No AC Hum/Buzz)
(Designated by Suffix “HF”) - The “HUM FREE” option
eliminates the“AC hum”associated with AC operated solenoid
valves. Enables valves to be used where an AC hum would
not be acceptable and AC is the only power source available.
IE: Hospitals, labs, schools (class rooms), homes, office envi-
ronments etc. & when 24 vac is required for 40 series valves.
Leak / Dead Tight:
(Normally Closed valves only)
(Designated by Suffix “LT”) - The Leak / Dead Tight Option
offers ‘soft’ resilient seating or ‘gapless’ seal for low pressure
applications 50 PSI or less. Consult Factory for Max. Diff. Pres-
sure and Valve Type availability.
Flanged Ends for Bronze and Stainless Steel Valves:
(Designated by Suffix“F1”for 150 lb or“F3”for 300 lb Flanges)
F1 or F3 Flanged ends available on all stainless steel valves.
F1 Flanged ends available on bronze valves. F3 Flanged ends
for bronze valves available through our Clark-Cooper Division.
Explosion-Proof and Watertight Solenoids:
(Designated by Prefix “F”) – are Explosion-proof and NEMA
4, 7C & D, 9E, F & G suitable for use in hazardous locations
requiring Class I, Groups C & D & Class II Groups E, F, and G
equipment.
NEMA 4X:
(Designated by Prefix “F” AND Suffix “ZP”) – are suitable for
use in locations requiring a NEMA 4X designation. “ZP” (Zinc
Plating) replaces the standard paint used on the Coil housing
(cup and base). The additional corrosion protection satisfies
NEMA 4X requirements.
Internal construction, pressure ratings, power consumption,
and external dimensions are the same as for standard valves.
Nickel Plating:
(Designated by Suffix“NP”) - Plating is 0.0005” Thick Meets Mil
Spec. C26074
Universal MountValves For Mounting InVertical Pipe Runs
(See Magnatrol Universal Mount Catalog 3006-UM)
OTHER OPTIONS
27. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
2727
BULLETIN 3006-POS/IND
POSITION INDICATORS
For Normally Closed Solenoid Valves
Position Switches
CONSTRUCTION:
Housing - 316 Stainless Steel with 1/2”NPT Conduit Connection
Contact - SPDT (Single Pole/Double Throw)
Lead Wires - 36 inches long, 18 gauge standard leads potted-in PVC
OPERATION:
Switch is activated by a ferromagnetic“target”attached to the valve’s piston
“PS”- General Purpose/NEMA 4, 4X
“PSF”- Explosion Proof
SPDT Contact
Electrical Rating:
4A @ 120 VAC / 3A @ 24 VDC
2A @ 240 VAC / 1.25A @ 48 VDC
0.5A @ 125 VDC & 250 VDC
The PS and PSF can be wired AC or DC, N/O or N/C,
consume no power to operate, and leave no current
leakage or voltage drop
Position Switches With LED Visual Indication
“PL”- General Purpose/NEMA 4, 4X
“PLF”- Explosion Proof
SPDT Contact
Electrical Rating:
0.25A @ 120 VAC / 3A @ 24 VDC
(3A @ 120 VAC / 2A @ 24 VDC without the LEDs)
The PL and PLF can be wired AC or DC, N/O or N/C
Ambiant Temperature: -40°F to 221°F (106°C)
Position Display - Visual Indication ONLY
“PD”- General Purpose / NEMA 4, 4X / Explosion Proof
CONSTRUCTION:
Housing - Clear High-Strength Polycarbonate
APPLICATION:
Visual indication that valve is Open / Closed
OPERATION:
When the valve is in the closed position, a ferromagnetic “target” attached to
the valve’s piston, lifts a green colored magnet into the adapter hiding it from
view. When the valve is energized, (open position), the magnet drops down to
a visible position.
Position Indicators for Normally Closed Valve Only
Available on Type A, S, L, K, W & G Valves
NOTE: ONLY ONE BOTTOM
MOUNTED OPTION CAN BE
INSTALLED ON EACH VALVE
HOW TO ORDER:
Indicate Option when Ordering:
Use the appropriate Prefix:
PS, PSF, PL, PLF, or PD
Example:
PS18A44 indicates a Position
Switch mounted on a Type
18A44 valve.
For multiple switches and where
a switch and a bottom mounted
option are required, contact our
Clark Cooper Division.
(See bottom of Page 3)
PS shown with valve
body adaptor
Position Switch on right
shown energizing Red LED
PS General Purpose & Water Tight (SPDT
Switch) shown on 3” Stainless Steel Valve
28. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
28
BULLETIN 3006-
BRONZE SOLENOID VALVES
Dependable • Packless
TYPE“P”FULL PORT - NORMALLY CLOSED
1/2” TO 1-1/2”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve
opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon
de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure
to build“above”the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Plunger Spring - 304 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*
*
APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine,
Vacuum and any other fluids not reactive with construction
materials and free of sediment. Valve operates from zero to maximum
differential pressure indicated in table. Valve can be mounted in
ANY POSITION (See box at right).
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
Explosion Proof:
Available for DC Power
Source ONLY (Valves
without“HF”suffix). Use
Prefix“F”(i.e. F118P44).
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
118P42HF
118P32HF
118P52HF
118P23HF
118P43HF
133P33HF
133P53HF
118P24HF
28
28
33
28
1/2
3/4
1
1-1/2
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
Ship
Wt.
Lbs. A B C D
110
200
300
50
110
200
300
50
7
7-1/2
8-1/8
7-7/8
5-7/8
6
7
6-5/8
2-3/4
2-3/4
3-1/4
3-1/2
4-1/8
8
8
12
10118P44HF
133P34HF
33
110
200
8-7/8 7-1/2 3-1/214133P54HF
41P46HF
300
115
41P36HF
41P56HF
35200
300
11 9-1/8 4-1/2 4-7/824
4-1/8
2-3/4
Dimension In Inches
The“P”Valve is:
Multipoised:
Ability to be mounted in
any position.
Spring Loaded:
The term used to indicate that
the valve has a plunger spring.
A spring-loaded plunger permits
the valve to be mounted in
any position without causing
malfunction.
29. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
29
BULLETIN 3006-SANDY WELL WATER
BRONZE SOLENOID VALVES
Dependable • Packless
“SANDY WELL WATER”FULL PORT - NORMALLY CLOSED
1/2” TO 3”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve
opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon
de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure
to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow of “Sandy Well Water”, the valve is designed
with the piston and other components“turned down”, offering
additional clearance, allowing the valve to operate with fluids
containing some sediment typically found in well water. Valve
operates from zero to maximum differential pressure indicated in
table. Valve must be mounted in horizontal pipe with solenoid
enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
†† Not available for
DC operation
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
18A22-V
118A22-V
18A23-V
118A23-V
233A23-V
18A24-V
118A24-V
133A24-V
25
40
1/2
1
1-1/4
1-1/2
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Ship
Wt.
Lbs. A B C D
50
80
50
75
125
50
75
125
7 5-7/8 2-3/4 3-1/48
233A24-V
65
200 80
3/4
2-1/2
3
2
18
28
Watts
AC
33
N/A
25
40
25
40
18
28
18
28
80 40
25
40
65
85
18
28
33
N/A
18A25-V
118A25-V
133A25-V
50
75
110
140A45-V300
35A26-V
135A26-V
41A26-V
50
75
125
45
65
23
33
60 35
36A17-V
136A17-V
136A27-V
30
50
75
45
65
65
43A18-V
143A18-V
243A18-V
30
50
75
60
85
115
44A19-V
144A19-V
244A19-V
30
50
75
60
85
115
42A27-V
142A27-V
125
185
60
85
35
45
65
23
33
33
35
45
35
45
65
7-1/8 6 2-3/4 3-1/28
8-1/8 7 3-1/2 3-1/212
7-7/8 6-5/8 2-3/4 4-1/810
8-7/8 7-1/2 2-3/4 4-1/814
8-3/8 6-3/4 2-3/4 4-1/212
9-3/8 7-3/4 3-1/2 4-1/216
10 8-1/8 4 4-7/820
11 9-1/8 4-1/2 4-7/824
11 8-3/4 5-3/8 631
12 9-3/4 5-3/8 636
12-7/8 10-1/8 5-7/8 7-1/443
13-3/4 10-1/2 6-5/8 8-3/856
Dimension In Inches
30. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
30
BULLETIN 3006-GRITTY COOLANT/NORMALLY CLOSED
BRONZE SOLENOID VALVES
Dependable • Packless
“GRITTY COOLANT“ FULL PORT - NORMALLY CLOSED
1/2” TO 1-1/2”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve
opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon
de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure
to build above the piston and seat it.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Pilot Valve - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - Inconel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow of“Coolant”, the valve is designed with the piston
“turned down” and a larger pilot port, offering additional clearance,
allowing the valve to operate with fluids containing some grit/sedi-
ment typically found in coolant.Valve operates from zero to maximum
differential pressure indicated in table. Valve must be mounted in hor-
izontal pipe with solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
†† Not available for
DC operation
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
“A”Dimension does not include the“MS”Mounting Stud (Approx. 7/8”)
Note: The addition of any bottom mounted option would replace the“MS”Mounting
Stud and change the prefix to reflect the appropriate option.
MS18A42-C
MS33A22-C
MS233A42-C
MS18A43-C
MS33A23-C
MS133A23-C
MS233A43-C
65
80
1/2
1
1-1/4
1-1/2
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Ship
Wt.
Lbs. A B C D
80
200
300
80
125
200
300
7 5-7/8 2-3/4 3-1/48
3/4
33
40
Watts
AC
25
40
80
25
18
23
40
18
45 23
80
80
40
40
MS233A24-C
MS233A44-C
200
300
MS233A25-C
MS233A45-C
MS241A46-C
200
300
300
80
80
40
40
115 65
7-1/8 6 2-3/4 3-1/28
8-1/8 7 3-1/2 3-1/212
7-7/8 6-5/8 2-3/4 4-1/810
8-3/8 6-3/4 2-3/4 4-1/212
10 8-1/8 4 4-7/820
Dimension In Inches
31. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
31
BULLETIN 3006-GRITTY COOLANT/NORMALLY OPEN
BRONZE SOLENOID VALVES
Dependable • Packless
“GRITTY COOLANT“ FULL PORT - NORMALLY OPEN
1/2” TO 1-1/2”PIPE SIZE
NO DIFFERENTIAL PRESSURE REQUIRED TO OPEN
OPERATION:
Valve closes when energized and opens when de-energized. When the coil is energized the plunger
presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build
above the piston and sealing it. Upon de-energizing the coil, the pilot orifice is opened, relieving the
pressure above the piston, allowing it to leave its seat. The bottom spring allows the valve to operate at
zero pressure drop.
CONSTRUCTION: (* Wetted parts)
*Valve Body - Cast Bronze, Globe Pattern - NPT ends
*Piston - Cast Bronze
Coil Enclosure - Malleable or Cast Iron, 1/2”NPS conduit conn.
*Plunger - 430 Stainless Steel
*Poppet - 303 Stainless Steel
*Stem - 303 Stainless Steel
*Bonnet Tube - 304 Stainless Steel
*Spring - Inconel and 302 Stainless Steel
*Body Seal - Buna N or Non Asbestos Gasket
*Orifice Seal - Buna N (Viton or Glass Filled Teflon available)
*AC Shading Coil - Copper
*Stem Pin - 304 Stainless Steel
Coil - Encapsulated Class B, 18”leads - (Class H available)
APPLICATION:
To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacu-
um and any other fluids not reactive with construction materials and
free of sediment. Valve operates from zero to maximum differential
pressure indicated in table. Valve must be mounted in horizontal pipe
with solenoid enclosure vertical and on top.
Strainers are
recommended
for use with
solenoid valves
(See page 19)
When you order
please supply the
following:
• Pipe Size
• Valve Type
• Voltage (AC or DC)
• Hertz
• Fluid
• Fluid Temperature
• Max. Diff. Pressure
• Optional Features
(See pages 26 & 27)
†† Not available for
DC operation
MAX. FLUID TEMP.
212° F
MAX. STATIC PRESSURE
300 PSI
Except valves listed for 500 PSI
FOR OPTIONS &
ACCESSORIES
SEE PAGES 26 & 27
“A”Dimension does not include the“MS”Mounting Stud (Approx. 7/8”)
Note: The addition of any bottom mounted option would replace the“MS”Mounting
Stud and change the prefix to reflect the appropriate option.
MS33AR42-C
MS18AR23-C
MS233AR43-C
MS33AR44-C
MS233AR24-C
MS233AR44-C
45
80
1/2
1
Pipe
Size
Inches
Max
Diff.
PSI
Type No. Watts
AC
Ship
Wt.
Lbs. A B C D
200
50
110
110
200
300
9-3/8 8-1/4 4-1/8 3-1/48
80
3/4
23
40
Watts
AC
40
45
25
80
23
18
40
8-1/4 7-1/8 2-3/4 3-1/29
10 8-5/8 3-1/2 4-1/814
9-1/4 8-1/8 3-1/2 3-1/213
Dimension In Inches
32. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
3232
BULLETIN 3006 - RFQ
REQUEST A QUOTE
Fill In The Information Below
If you have any questions or wish to request a quote:
Phone: 973-427-4341 • Fax: 973-427-7611
E-Mail: info@magnatrol.com
We appreciate the opportunity to quote on your requirements.
For immediate quote – Fill in the information below and CALL: 973-427-4341
For same day quote – Fill in the information below and FAX: 973-427-7611
For quote within 24 hrs – Go online to www.magnatrol.com, and go to Quick Quote
Company Name: Phone:
Contact (Your Name): Fax:
Your RFQ Reference (If Any):
Type of Business: OEM Re-Seller Consumer/End User
E-Mail:
Desired Delivery:
Your Reference (Optional):
Quantity:
Valve Construction Material: Bronze or Stainless Steel
Pipe Size: (1/4”thru 3”):
Normally: Closed (Energize To Open) or Open (Energize To Close)
Voltage: AC: Volts/ Hz or DC: Volts
Maximum Differential Pressure: PSI
Fluid:
Maximum Fluid Temperature: °F
Optional Feature: (See Optional Feature Details On Pages 26 & 27)
Choose One (1) Of The Following Per Valve: MO LV DP FC MS DR PD PS PL
Additional Options: HF LT NP PT DN ZP (Can be combined with one (1) of the above Optional Features)
Enclosure Options: General Purpose Explosion Proof NEMA 4 NEMA 4X
(For Solenoid Housing) (Prefix“G”- NEMA 12) (Prefix“F”) (Prefix“E”) (Prefix“E”& Suffix“ZP”)
Comments:
YOUR COMPANY DATA
VALVE DATA
Quantity Discounts: Consult Factory
Delivery: Most orders ship in 7-10 days. Small emergency orders can be shipped in 1-2 days.
33. MAGNATROL VALVE CORPORATION
Magnatrol Valve Corporation • P.O. Box 17 • 67 Fifth Avenue • Hawthorne • New Jersey • 07507
info@magnatrol.com • Phone: 973-427-4341 • Fax: 973-427-7611 • www.magnatrol.com
33
BULLETIN 3006 - ORDER GUIDELINES
ORDERING GUIDELINES
Magnatrol Solenoid Valves
If you have any questions or wish to request a quote:
Phone: 973-427-4341 • Fax: 973-427-7611
E-Mail: info@magnatrol.com
MAGNATROL VALVE TYPE NUMBER DETAIL
For Additional Information On Options See Optional Features Pages 26 & 27
PREFIX
OPTION
FIELD
SOLENOID
ENCLOSURE
FIELD
VALVE TYPE NUMBER
Refer To Individual Bulletins
For Type Number
Options: (Choose One)
DP - Dashpot (Consult
factory for valve
type availability)
DR - Drain Plug **
FC - Flow Control **
LV - Lever *
MO - Manual Override *
MS - Mounting Stud
PD - Position Display *
PL - PositionSwitchw/LED*
PS - Position Switch *
Enclosures:
G - General Purpose NEMA12
E - NEMA 4
- NEMA 4X
F - Explosion Proof & NEMA 4
CR - Clean For Freon/Refrigerant
CY - Clean For Oxygen
CZ - Clean For Cryogenics
DN - Din Connector
HF - Hum Free
HT - High Temperature Coil
LL - 6’Long Lead Wires
LT - Leak Tight (Soft Seat Pilot)
NP - Nickel Plated (.005 Thickness)
Meets Mil Spec C26074
PT - Pilot Tap ***
RB - Reducing Bushing
ZP - Zinc Plated Solenoid Housing
Metal Tags:
AL - Aluminum Tag
SS - Stainless Steel
=
==
===
Kerosene, Gasoline, Naptha, Alcohol, Soluable Oil, Coolant, Freon and Refriger-
ant).
* Normally Closed Valves Only
** Normally Closed and NR & MR Valves/FC not available on G valve type
*** Pilot Tap: Can be used along with any other option.
Available On Type D, G and GR only.
END
CONNECTION
TYPE
VOLTAGE
DESC.
HERZ
DESC.
VALVE
DISC
FLUID
FIELD
SUFFIX OPTION
FIELD(S)
(Add As Required)
End Connection
Description:
SC - Screwed, FNPT
F1 - 150# Flange
F3 - Flanged
Voltage
Description:
A - 120
B - 208
C - 240
D - 480
E - 575
F - 6
G - 12
H - 24
Hertz
Description:
A - 50/60
B - 50
C - 60
D - DC
Disc
Material: =
B - Buna N
T -
V - Viton
M - Metal
Fluids:
C - Gritty Coolant
G - Gas/Air/Oxygen
H - Hot Liquid ==
O - Oil/Fuel Oil
S - Steam
V - Sandy Well Water
W - Cold Liquid ===
Z - Cryogenics/Liquid O2
Check individual
bulletins for
listed valves
Consult Factory for Assistance with:
• Additional voltages
• End Connections not shown
• Fluid Field designations
NOTE: (For N, NR, M, MR, J & JR this field is used to show a change to the Valve Body Seal Material
34. TERMS & CONDITIONS OF SALE
CONTACT INFORMATION
Catalog: This catalog supersedes all previous issues.
Quotations: Quotations are made for acceptance within
60 days and are subject to change or withdrawal without
notice.
Prices and Discounts: All prices and discounts are in
accordance with the prices and discounts established by
Magnatrol and are subject to change without notice.
Terms: Net 30 days, subject to establishment of credit.
Shipments: All shipments are F.O.B. factory, Hawthorne,
New Jersey. Our responsibility ends with delivery of
merchandise to the transportation company and issuance
to us of formal shipping receipt.
Minimum Billing: Minimum billing charge is $50.00 net.
Cancellations: Orders are subject to cancellation only
with our consent.
Shipping Date: There shall be no liability for default or
delay in shipping. All orders, contracts, and agreements are
made subject to delays contingent upon accidents, strikes,
embargoes or other causes beyond our control.
Design and Materials: All materials and designs are
subject to change without notice.
Weights and Dimensions: Weights and dimensions listed
in this catalog are as close to actual as is practicable but are
not guaranteed and are subject to change without notice.
Errors: All clerical errors are subject to correction.
Returns for Repair: Valves retuned for repair must be
shipped prepaid and accompanied by a detailed report
regarding service application, installation and nature of
trouble or malfunction.
Returns for Credit: Returns for credit will be accepted
only with our consent. Credit will be subject to restocking
charge and any additional expenses incurred in restoring
valves to salable condition. Credit will be issued only to
original purchaser.
Taxes: Any manufacturer’s excise tax, use tax, sales tax or
tax or duty of any nature shall be paid by the buyer. In
the event that the seller is required to pay any such tax-
es or duties, the buyer shall reimburse seller therefore.
The buyer may provide seller with an exemption certifi-
cate or other documents acceptable to taxing or customs
authorities at the time an order is placed.
Guarantee: MAGNATROL valves are guaranteed to be
free from any defects in material and workmanship for
one year or 500,000 cycles, whichever comes first. Our
guarantee solely conveys the right to repair or replace free
of charge, any defective valves, or parts, thereof, returned
to us transportation charges prepaid, within one year after
date of original shipment from factory.
This guarantee shall not apply if the valve has been:
• Improperly Installed
• Used for other than intended service
• Repaired without authorization
BULLETIN 3006 - TERMS & CONDITIONS
Solenoid valve questions can be answered quickly and accurately over the phone:
Phone: 973-427-4341 • Fax: 973-427-7611
TERMS & CONDITIONS OF SALE
MAGNATROL CONTACT INFORMATION
Sales, Service, Phone: 973-427-4341
Tech Support: Fax: 973-427-7611
Email: info@magnatrol.com
techsupport@magnatrol.com
Mailing Address: PO Box 17
Hawthorne, NJ 07507
Shipping Address: 21 Horton Avenue
Hawthorne, NJ 07506
Administrative: 67 Fifth Avenue
Hawthorne, NJ 07506
www.magnatrol.comwww.magnatrol.com
Check individual
bulletins for
listed valves
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.