The document provides guidance on inspecting radial gates in dams. Key areas to inspect include anchor girders, trunnion brackets, end arms, horizontal girders, gate leafs, seals, rollers, embedded parts, hoist mechanisms, connecting assemblies, wire ropes, platforms, bridges, cranes, stoplogs, communication systems, generators, control rooms, and lighting/electrical equipment. Inspections should check for cracks, corrosion, wear, alignment, and proper functioning of all parts, and identify needed repairs.