CARE OF CHILD IN INCUBATOR
INCUBATOR
“Incubare” latin = to lie on
A microenvironment to place newborns
who are at high risk, for maintenance of
temperature and humidity.
PURPOSES


Maintenance of thermo neutral ambient
temperature.



Provision of desired humidity and
oxygenation.



Observation of very sick neonates.



Isolation of newborn babies from
infection, unfavorable external
INDICATION


Premature babies



Babies with low birth weight (<1500gm)



Hypothermic child (<320C)



Sick children



Also used in case of transportation of babies
from one hospital to another.



Also used to shift babies within the hospital for
various investigations. E.g, CT Scan and MRI.
TYPES
1.

Portable

2.

Standard
PARTS OF AN INCUBATOR
Hood

/ canopy
Cabinet
Access panel
Mattress
Arm port holes
Bassinet
Latch release











Control panel
Oxygen inlet
Thermostat
Air inlet filter
Access port
Caster lock
Levers
DISPLAY


Air temperature



Patient temperature



Control temperature
PROCEDURE
1.

2.

Warm and oxygenate the incubator as you
receive the message of expected arrival
of neonate, generally 10-15 minutes earlier.
Check the physician’s order.

3.

Explain the needs of incubator care to the
parents of neonate.

4.

Adjust the incubation parameters and
maintain, follow the chart.

5.

Remove the cloths of the neonate and place
inside the incubator.
6. Provide meticulous care as long neonate
remains inside.

7. Continue care through port hole.

8. Report to the doctor if baby is not
maintaining the temperature, generally
after two abnormal readings.
9. Do not bring the neonate out without
justifiable cause.

10. Document time and condition of the
neonate
NURSING CARE OF CHILD
THANK YOU

Care of child in incubator

  • 1.
    CARE OF CHILDIN INCUBATOR
  • 2.
    INCUBATOR “Incubare” latin =to lie on A microenvironment to place newborns who are at high risk, for maintenance of temperature and humidity.
  • 3.
    PURPOSES  Maintenance of thermoneutral ambient temperature.  Provision of desired humidity and oxygenation.  Observation of very sick neonates.  Isolation of newborn babies from infection, unfavorable external
  • 4.
    INDICATION  Premature babies  Babies withlow birth weight (<1500gm)  Hypothermic child (<320C)  Sick children  Also used in case of transportation of babies from one hospital to another.  Also used to shift babies within the hospital for various investigations. E.g, CT Scan and MRI.
  • 5.
  • 6.
    PARTS OF ANINCUBATOR Hood / canopy Cabinet Access panel Mattress Arm port holes Bassinet Latch release        Control panel Oxygen inlet Thermostat Air inlet filter Access port Caster lock Levers
  • 7.
  • 8.
    PROCEDURE 1. 2. Warm and oxygenatethe incubator as you receive the message of expected arrival of neonate, generally 10-15 minutes earlier. Check the physician’s order. 3. Explain the needs of incubator care to the parents of neonate. 4. Adjust the incubation parameters and maintain, follow the chart. 5. Remove the cloths of the neonate and place inside the incubator.
  • 9.
    6. Provide meticulouscare as long neonate remains inside. 7. Continue care through port hole. 8. Report to the doctor if baby is not maintaining the temperature, generally after two abnormal readings. 9. Do not bring the neonate out without justifiable cause. 10. Document time and condition of the neonate
  • 11.
  • 12.