International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3597
EFFECT OF VISCOUS DAMPERS ON RESPONSE REDUCTION FACTOR FOR
RCC FRAME USING RESPONSE SPECTRUM ANALYSIS
Miss Shital D. Zolekar1, Prof. A. V. Sagade2
1P. G. Student, Department of Civil Engineering, Trinity College of Engineering & Research, Pune,
Maharashtra, India
2Assistant Professor, Department of Civil Engineering, Trinity College of Engineering & Research, Pune,
Maharashtra, India
---------------------------------------------------------------------***----------------------------------------------------------------------
Abstract - Response reduction factor (R) is the parameter
which represents the capacity of structure to dissipate energy
through inelastic behavior. Increased value of response
reduction factor for a structure resembles increased
inelasticity of the structure towards seismic forces. Viscous
damper is a device which is installed in the structures todamp
seismic forces by energy dissipation. Responsereduction factor
(R) is a seismic design parameter which determines nonlinear
behaviour of RCC structuressubjectedtoearthquake. From the
literature review it is seen that the study on the effect of
viscous dampers on the response reduction factor (R) is
lagging. Thus, the effect of viscous dampers on the response
reduction factor (R) of reinforcedconcretestructuresinstalled
with viscous dampers has been studied. Overstrength,
redundancy and ductility factors are the parameters, used to
formulate response reduction factor (R). The performance of
reinforced concrete structures in seismic conditions is
improved by damping action of viscous dampers. ETABS 2016
software was used to determine the effect of viscous dampers
on the behaviour of reinforced concrete building installed with
dampers on different locations of the building and at various
storeys of building. The effect of nonlinear viscous damper on
overstrength, ductilityandresponsereductionfactorofspecial
moment resisting frame (SMRF) frames is also studied. The
results of the analysis showed that, the value of response
reduction factor (R) for reinforced concrete building installed
with dampers was higher than the building without damper.
Key Words: Response Reduction Factor, Viscous Damper,
Ductility Factor, Overstrength Factor, Redundancy Factor,
Dynamic Analysis.
1. INTRODUCTION
The main purpose & intention of conventional structural
design for the structures in seismic zones is human life
protection. To serve the intended purpose,itisnecessaryfor
the structure to refrain collapse, even though highly
damaged by the seismic action. This is the basic concept of
the ductility of structure. Response reduction factor for any
structure represents ductility and the same is incorporated
in the design of structure through responsereductionfactor.
The response reduction factor (R) is a seismic design
parameter that determines the nonlinear performance of
building structuresduringstrong earthquakes.Thestructure
may loose all its functionality (partial / complete) after
seismic actions. Retrofitting of such structures affected by
earthquakes may become very intricate or even impossible
in some cases. In order to reduce the deleterious effects of
earthquakes on the stability of structures, it is necessary to
mitigate the effect of seismic action on the structure by
providing a catalyst in structure. This can be achieved by
providing an emerging technology known as viscous
dampers. Viscous dampers functions on the principle of
passive energy dissipation by adding damping of seismic
forces in the structure. Previous study on response of
structure to earthquakes provided with viscous damper
shows that it can reduce storydrift,forcesin memberswhich
leads to less damage to structure enabling it to resist large
lateral force. It is very important to safeguard the structures
such as airports, fire department barracks, nuclear power
plants, communication centers, hospitals, bus stops,
institutions etc from the earthquakes to reachhigherlevel of
safety. By the virtue of damping action of viscousdampers,it
reduces forces in the members,enablingprovisionofsmaller
cross sections of structural members. This makes the
construction of the structure more cost efficient and light
weight which favours response of structure against seismic
action.
2. RESPONSE REDUCTION FACTOR
Response reduction factor determines level of inelasticityof
structure expected in lateral structural systems during an
earthquake. The concept of R is based on assumption that
the well detailed seismic framing system can sustain large
inelastic deformations without collapse.
Calculation of design base shear is as given below (IS 1893),
The definition of response reductionisintroducedbyATC19
(1995) in the form of equation as shown below,
Where R is response reduction factor, is over strength
factor, is ductility factor, isredundancyfactorand is
damping factor.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3598
Effects of added damping is ratiocinated by documents such
as ATC (1995) damping to reduce the force response of
buildings. Equation of response reduction appeared in
various literatures is as shown below,
2.1 Overstrength Factor ( )
Overstrength factor determines the yielding of structure at
higher load than design load because of various factors like
partial load factors appliedtogravityloadsandsafetyfactors
applied to material strengths. It is represented intheform of
equation as shown below,
Where Vd is the design base shear force in the building
calculated (IS 1893:2002) & Vy is the yield base shear force
that corresponds to actual yielding of structure.
2.2 Ductility Factor (Rµ)
The ductility factor ( ) determines nonlinear response ofa
structure that occurs from hysteretic energy. It reduces the
elastic force demand to the level of idealized yield strength
of the structure
Ductility factor was developed by Newmark and Hall (1982)
as follows,
Rμ = 1 for T < 0.2 s
Rμ = for 0.2 s < T < 0.5 s
Rμ = μ for T > 0.5 s
𝜇 =
2.3 Redundancy Factor (Rr)
The redundancy factor (Rr) is a measure of repetitions in a
lateral load resisting system. The moment resisting frames,
shear walls or their aggregates are the most chosen lateral
load resisting systems in RC structures.ASCE7recommends
a redundancy factor Rr = 1.0 forsystemswithparallel frames
and the corresponding is adopted for this work as the case
study structures fall in this category.
Table – 1: Redundancy factor (Rr) from ATC
Lines of vertical
framing
Drift Redundancy
factor
2 0.71
3 0.86
4 1.0
2.3 Fluid Viscous Dampers (FVD)
The primary aim of energy dissipation devices is to mitigate
displacement of the structures due to earthquakes. Energy
dissipation is better alternative to conventional stiffening
and strengthening schemes and would be expected to
achieve comparable performance levels. Fluid viscous
dampers were initially used in the military and aerospace
industry. They were used in structural engineering in the
late 1980’s and early 1990’s. Fluid viscous dampers consists
of a piston head with orifices contained in a cylinder filled
with a highly viscous fluid, usually a compound of silicone or
a similar type of oil. Energy is dissipated in the damper by
fluid orificing when the piston head moves throughthefluid.
The fluid in the cylinder is nearly incompressible and when
the damper is subjected to a compressive force, the fluid
volume inside the cylinder is decreased as a result of the
piston rod area movement. A decrease in volume resultsina
restoring force. This force is undesirable and is usually
prevented by using a run-through rod that enters, the
damper is connected to the piston head and then passes out
the other end of the damper. Another method forpreventing
the restoring force is to use an accumulator. An accumulator
works by collecting the volume of fluid that is displaced by
the piston rod and storing it in the make-up area. As the rod
retreats, a vacuum that has been created will draw the fluid
out. A damper with an accumulator is illustrated in fig. 1.
Fig – 1: Fluid Viscous Damper (FVD)
Fluid viscous dampers have the unique advantage of
reducing the shearing and bendingstresses atthesametime,
as the velocity-dependent maximum damping force is 90
degrees out of phase with the maximum deflection of the
structure. In addition, installing FVDs in a structuredoesnot
alter its force displacement relationship.
3. STRUCTURAL MODELLING
RCC buildings of 4, 8, 12 and 16 storey, symmetric in plan
are considered in present study. To represent the effect of
time period on response structure, structures with various
storey were considered. It had 3 bays in both the directions
with bay width of 6 m. The height of all stories was taken as
3 m. The seismic forces on these buildings were determined
as per IS 1893:2002. These RC buildings were designed for
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3599
both gravity and earthquake forces based on guidelines
given by IS 456:2000 and IS 13920:1993.
Fig – 2: Structural arrangement of four buildings in plan
The data used for design is as follows:
Table – 2: Material Properties
Storey Grade of concrete Grade of steel
4 M20 Fe 500
8 M25 Fe 500
12 M30 Fe 500
16 M30 Fe 500
 Imposed load for Institutional structureis3kN/ .
 Floor finish load is 1.5 kN/ .
 Wall load on beams are assumed as 12 kN/m for
outer walls and 6 kN/m for inner walls.
 Floor slabs are assumed as 200 mm thick.
 Damping coefficient 770 kNs/m.
 Building frame is modeled as rigid jointed frame i.e.
Special moment resisting frame.
Table – 3: Properties of Fluid Viscous Damper
Sr.
No
Damping
coefficient
(kNs/m)
Force
(kN)
Stiffness
(kN/m)
Mass
(kg)
1. 770.0 733.9 3850000 150
2. 1027.4 978.6 5137050 215
3. 1541.1 1467.9 7705000 300
4. 2054.8 1957.2 10274000 450
Details of models considered in present study are discussed
below. In configuration I (CONFI-I), viscous dampers are
added in middle bays of frame and in configuration II
(CONFI-II), viscous dampers are added in corner bay but i.e.
different location of frame through overall height of
structure.
I. 4 storey building
(a) (b)
(c)
(a) Structure without damper; (b) Structure with damper
CONFI-I; (c) Structure with damper CONFI-II
Fig – 3: 4 storey RCC building with different damper
configurations
II. 8 storey building
(a) (b)
(c)
(a) Structure without damper; (b) Structure with damper
CONFI-I; (c) Structure with damper CONFI-II
Fig - 4: 8 storey RCC building with different damper
configurations
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3600
III. 12 storey building
(a) (b)
(C)
(a) Structure without damper; (b) Structure with damper
CONFI-I; (c) Structure with damper CONFI-II
Fig – 5: 12 storey RCC building with different damper
configurations
IV. 16 storey building
(a) (b)
(c)
(a) Structure without damper; (b) Structure with damper
CONFI-I; (c) Structure with damper CONFI-II
Fig – 6: 16 storey RCC building with different damper
configurations
Table - 4: Details of RC section
Building Floor Column(mm) Beam(mm)
4 storey
1-2 500x500 230x450
3-4 450x450 230x450
8 storey
1-5 650x650 300x500
6-8 500x500 300x500
12
storey
1-4 750x750 300x600
5-8 650x650 300x600
9-12 550x550 300x600
16
storey
1-4 850x850 300x600
5-8 750x750 300x600
9-12 650x650 300x600
13-16 550x550 300x600
4. SEISMIC ANALYSIS
Seismic analysis is a subset of structural analysis and is the
calculation of the response of a building structure to
earthquakes. It is part of the process of structural design,
earthquake engineering or structural assessment and
retrofit in regions where earthquakes are prevalent. The
behaviour of structure, external action, and the kind of
structural design selected, is the key to this analysis.Also,on
the basis of the behavior of the structureand external action,
the analysis is further categorized as (i) Linear Static
Analysis, (ii) Nonlinear Static analysis, (iii) Linear Dynamic
analysis, and (iv) Nonlinear Dynamic analysis.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3601
Table – 5: Response reduction factor for 4 Storey building
G+3 Storey
(mm) (mm) R
Without FVD 984.421 949.680 1.0366 48 17.94 2.0860 1 2.1623
With FVD CONFI-I 985.542 950.961 1.0364 48 13.12 2.5130 1 2.6044
With FVD CONFI-II 985.542 950.961 1.0364 48 13.76 2.5543 1 2.5972
Table - 5: Response reduction factor for 8 Storey building
G+7 Storey
(mm)
(mm) R
Without FVD 2203.277 2116.423 1.0410 96 46.62 2.0593 1 2.1438
With FVD
CONFI-I
2205.679 2118.985 1.0409 96 33.81 2.8394 1 2.9556
With FVD
CONFI-II
2205.679 2118.985 1.0409 96 34.09 2.8158 1 2.9310
Table – 6: Response reduction factor for G+11 Storey building
12 Storey
(mm) (mm) R
Without FVD 2477.673 3338.171 0.7422 144 51.93 2.7732 1 2.0583
With FVD CONFI-I 2480.297 3342.015 1.0419 144 40.11 3.5898 1 3.7400
With FVD CONFI-II 2480.297 3342.015 1.0419 144 41.22 3.4939 1 3.6401
Table - 7: Response reduction factor for G+15 Storey building
16 Storey
(mm)
(mm) R
Without FVD 2536.220 4554.324 0.5569 192 69.81 2.7505 1 1.5317
With FVD
CONFI-I
2538.873 4559.448 1.0423 192 51.99 3.6932 1 3.8493
With FVD
CONFI-II
2538.873 4559.448 1.0423 192 54.06 3.5514 1 3.7015
Table – 8: Comparison of response reduction factor without viscous dampers, with viscous dampers Configuration I &
with viscous dampers Configuration II
Storey
Without
Damper
With FVD
CONFI. I
With FVD
CONFI. II
Values of R
4 2.1623 2.6044 2.5972
8 2.1438 2.9556 2.9310
12 2.0583 3.7400 3.6401
16 1.5317 3.8493 3.7015
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3602
Fig – 7: Response Reduction Factor
6. CONCLUSIONS
Following are the conclusions of the study:
1. A constant value of R for any case of building cannot be
justified. Well-defined methods are requiredtofindout
the R value accounting for strength, ductility,
redundancy and damping for any particular building;
present work takes efforts in the same line of action.
2. It is observed that implementation of viscous dampers
reduce the storey displacement, drift, acceleration
occurred in RCC building and increases the base shear
capacity.
3. R factors computed are highly dependent on the height
of building, viscous damper capacity and the input
ground motion.
4. Buildings with dampers can resist more lateral loads
compared to building without damper at nearly same
displacement.
5. For this study, R factor for buildingwithConfigurationI
and II increases as height of building increases.
6. The advantage of viscous dampers is clearly
demonstrated by increase in response reduction factor
and improvement in performance of the building
during an earthquakehasbeenproven.Therefore,FVDs
are effective for enhancement of RCC buildings
performance when subjected to dynamic excitations.
7. It is observed that overstrength factor slightly
decreases with increase in damping capacity and also
ductility factor is increased in building with increase in
capacity of dampers.
8. It is observed that ductility factor is increased in
building with dampers.
7. REFERENCES
A. Mondal, G .Siddhartha and G. Reddy (2013),
“Performance-based evaluation of the response reduction
factor for ductile RC frames”, Journal of Engineering
Structures, Vol. 56,pp. 1808-1819.
A. Whittaker, G. Hart and C. Rojahn (1999),Seismicresponse
modification factors. Journal of Structural Engineering. Vol.
125, no. 4, pp. 438-444.
F. Hejazi, J. Noorzaei, M. Jaafar and A. Abang Abdullah
(2009), “Earthquake Analysis of Reinforce ConcreteFramed
Structures with Added Viscous Dampers”, International
Journal of Applied Science, EngineeringandTechnology,Vol.
65, pp. 284-293.
H. Abdi, F. Hejazi, R. Saifulnaz, I. Karim and M. Jaafar (2015),
“Response Modification Factor for Steel Structure Equipped
with Viscous Damper Device”, International Journal of Steel
Structures, Vol. 15, no. 3 pp. 605-622.
J. Hwang, Y. Huang, S. Lian Yi and S. Yen Ho (2012), “Design
Formulations for Supplemental ViscousDamperstoBuilding
Structures”, Journal of Structural Engineering,Vol.131,no.1,
pp.22-34.
M. ConstantinouandM.Symans(1993),“Experimental Study
of Seismic Response ofBuildings with Supplemental Fluid
Dampers”, The Structural Design of Tall Buildings, Vol. 2,pp.
93-132.
Mohsen Kargahi andChukwuma G. Ekwueme (2004),
“Optimization of ViscousDamperPropertiesforReductionof
Seismic Risk in Concrete Buildings”, 13th World Conference
on Earthquake Engineering, Paper No. 1027.
Oscar M. Ramirez, Michael C. Constantinou, Charles A.
Kircher, Andrew S. Whittaker,Martin W. JohnsonandJuan D.
Gomez (2000), “Development and Evaluation of Simplified
Procedures for Analysis andDesignofBuildingswithPassive
Energy Dissipation Systems”, Technical Report MCEER-00-
0010, University at Buffalo, State University of New York
Department of Civil, Structural and Environmental
Engineering Ketter Hall Buffalo, NY 14260.

More Related Content

What's hot

Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...IJERA Editor
 
Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...
Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...
Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...P. Pravin Kumar Venkat Rao
 
IRJET- Structural Analysis of Seismic Friction Dampers
IRJET-  	  Structural Analysis of Seismic Friction DampersIRJET-  	  Structural Analysis of Seismic Friction Dampers
IRJET- Structural Analysis of Seismic Friction DampersIRJET Journal
 
Strengthening of R.C Framed Structure Using Energy Dissipating Devices
Strengthening of R.C Framed Structure Using Energy Dissipating DevicesStrengthening of R.C Framed Structure Using Energy Dissipating Devices
Strengthening of R.C Framed Structure Using Energy Dissipating Devicespaperpublications3
 
IRJET- Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...
IRJET-  	  Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...IRJET-  	  Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...
IRJET- Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...IRJET Journal
 
Study on the effect of viscous dampers for RCC frame Structure
Study on the effect of viscous dampers for RCC frame StructureStudy on the effect of viscous dampers for RCC frame Structure
Study on the effect of viscous dampers for RCC frame StructurePuneet Sajjan
 
STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...
STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...
STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...IAEME Publication
 
IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...
IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...
IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...IRJET Journal
 
IRJET- Review on Seismic Analyses of RC Frame Structure by using Bracing ...
IRJET-  	  Review on Seismic Analyses of RC Frame Structure by using Bracing ...IRJET-  	  Review on Seismic Analyses of RC Frame Structure by using Bracing ...
IRJET- Review on Seismic Analyses of RC Frame Structure by using Bracing ...IRJET Journal
 
IRJET- Effect of Bracing and Unbracing in Steel Stuctures by using ETabs
IRJET-  	  Effect of Bracing and Unbracing in Steel Stuctures by using ETabsIRJET-  	  Effect of Bracing and Unbracing in Steel Stuctures by using ETabs
IRJET- Effect of Bracing and Unbracing in Steel Stuctures by using ETabsIRJET Journal
 
Rera and structural safety
Rera and structural safetyRera and structural safety
Rera and structural safetyWij Sangeeta
 
Evaluation of Seismic Behaviour of RCC Building using Coupled Shear wall
Evaluation of Seismic Behaviour of RCC Building using Coupled Shear wallEvaluation of Seismic Behaviour of RCC Building using Coupled Shear wall
Evaluation of Seismic Behaviour of RCC Building using Coupled Shear wallIRJET Journal
 
Effect of steel bracing on vertically irregular r.c.c building frames under s...
Effect of steel bracing on vertically irregular r.c.c building frames under s...Effect of steel bracing on vertically irregular r.c.c building frames under s...
Effect of steel bracing on vertically irregular r.c.c building frames under s...eSAT Journals
 
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...IRJET Journal
 
IRJET- Design of a New Passive Energy Dissipation System for Earthquake R...
IRJET-  	  Design of a New Passive Energy Dissipation System for Earthquake R...IRJET-  	  Design of a New Passive Energy Dissipation System for Earthquake R...
IRJET- Design of a New Passive Energy Dissipation System for Earthquake R...IRJET Journal
 
IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...
IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...
IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...IRJET Journal
 
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...IRJET Journal
 
Strengthening of RC Framed Structure Using Energy Dissipation Devices
Strengthening of RC Framed Structure Using Energy Dissipation DevicesStrengthening of RC Framed Structure Using Energy Dissipation Devices
Strengthening of RC Framed Structure Using Energy Dissipation DevicesIOSR Journals
 
Optimization of a multistorey building by optimum positioning of shear wall
Optimization of a multistorey building by optimum positioning of shear wallOptimization of a multistorey building by optimum positioning of shear wall
Optimization of a multistorey building by optimum positioning of shear walleSAT Journals
 

What's hot (20)

Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
Analysis and Capacity Based Earthquake Resistance Design of Multy Bay Multy S...
 
Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...
Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...
Effect of Seismic Zone and Story Height on Response Reduction Factor for SMRF...
 
IRJET- Structural Analysis of Seismic Friction Dampers
IRJET-  	  Structural Analysis of Seismic Friction DampersIRJET-  	  Structural Analysis of Seismic Friction Dampers
IRJET- Structural Analysis of Seismic Friction Dampers
 
R (2)
R (2)R (2)
R (2)
 
Strengthening of R.C Framed Structure Using Energy Dissipating Devices
Strengthening of R.C Framed Structure Using Energy Dissipating DevicesStrengthening of R.C Framed Structure Using Energy Dissipating Devices
Strengthening of R.C Framed Structure Using Energy Dissipating Devices
 
IRJET- Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...
IRJET-  	  Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...IRJET-  	  Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...
IRJET- Seismic Study of Multi-Storey Structure with Fluid Viscous Dampers...
 
Study on the effect of viscous dampers for RCC frame Structure
Study on the effect of viscous dampers for RCC frame StructureStudy on the effect of viscous dampers for RCC frame Structure
Study on the effect of viscous dampers for RCC frame Structure
 
STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...
STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...
STRUCTURAL RESPONSE CONTROL OF RCC MOMENT RESISTING FRAME USING FLUID VISCOUS...
 
IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...
IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...
IRJET- Response Reduction Factor and Push Over Analysis of Existing High Rise...
 
IRJET- Review on Seismic Analyses of RC Frame Structure by using Bracing ...
IRJET-  	  Review on Seismic Analyses of RC Frame Structure by using Bracing ...IRJET-  	  Review on Seismic Analyses of RC Frame Structure by using Bracing ...
IRJET- Review on Seismic Analyses of RC Frame Structure by using Bracing ...
 
IRJET- Effect of Bracing and Unbracing in Steel Stuctures by using ETabs
IRJET-  	  Effect of Bracing and Unbracing in Steel Stuctures by using ETabsIRJET-  	  Effect of Bracing and Unbracing in Steel Stuctures by using ETabs
IRJET- Effect of Bracing and Unbracing in Steel Stuctures by using ETabs
 
Rera and structural safety
Rera and structural safetyRera and structural safety
Rera and structural safety
 
Evaluation of Seismic Behaviour of RCC Building using Coupled Shear wall
Evaluation of Seismic Behaviour of RCC Building using Coupled Shear wallEvaluation of Seismic Behaviour of RCC Building using Coupled Shear wall
Evaluation of Seismic Behaviour of RCC Building using Coupled Shear wall
 
Effect of steel bracing on vertically irregular r.c.c building frames under s...
Effect of steel bracing on vertically irregular r.c.c building frames under s...Effect of steel bracing on vertically irregular r.c.c building frames under s...
Effect of steel bracing on vertically irregular r.c.c building frames under s...
 
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
IRJET- Behavior and Comparison of Multistory Building of Shear Wall with and ...
 
IRJET- Design of a New Passive Energy Dissipation System for Earthquake R...
IRJET-  	  Design of a New Passive Energy Dissipation System for Earthquake R...IRJET-  	  Design of a New Passive Energy Dissipation System for Earthquake R...
IRJET- Design of a New Passive Energy Dissipation System for Earthquake R...
 
IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...
IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...
IRJET- Comparative Analysis of Effects of Base Isolator & Fluid Viscous Dampe...
 
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
 
Strengthening of RC Framed Structure Using Energy Dissipation Devices
Strengthening of RC Framed Structure Using Energy Dissipation DevicesStrengthening of RC Framed Structure Using Energy Dissipation Devices
Strengthening of RC Framed Structure Using Energy Dissipation Devices
 
Optimization of a multistorey building by optimum positioning of shear wall
Optimization of a multistorey building by optimum positioning of shear wallOptimization of a multistorey building by optimum positioning of shear wall
Optimization of a multistorey building by optimum positioning of shear wall
 

Similar to IRJET- Effect of Viscous Dampers on Response Reduction Factor for RCC Frame using Response Spectrum Analysis

SEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDING
SEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDINGSEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDING
SEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDINGIRJET Journal
 
IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...
IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...
IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...IRJET Journal
 
Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...
Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...
Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...IRJET Journal
 
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...IRJET Journal
 
IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...
IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...
IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...IRJET Journal
 
Comparative Study on Seismic Behavior of Different Shape of RC Structure with...
Comparative Study on Seismic Behavior of Different Shape of RC Structure with...Comparative Study on Seismic Behavior of Different Shape of RC Structure with...
Comparative Study on Seismic Behavior of Different Shape of RC Structure with...IRJET Journal
 
Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...
Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...
Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...IRJET Journal
 
IRJET- Seismic Evaluation of Reinforced Concrete Structure with Friction ...
IRJET-  	  Seismic Evaluation of Reinforced Concrete Structure with Friction ...IRJET-  	  Seismic Evaluation of Reinforced Concrete Structure with Friction ...
IRJET- Seismic Evaluation of Reinforced Concrete Structure with Friction ...IRJET Journal
 
IRJET- Non Linear Static Analysis of Frame with and without Infills
IRJET- Non Linear Static Analysis of Frame with and without InfillsIRJET- Non Linear Static Analysis of Frame with and without Infills
IRJET- Non Linear Static Analysis of Frame with and without InfillsIRJET Journal
 
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...IRJET Journal
 
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...IRJET Journal
 
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...IRJET Journal
 
IRJET- Progressive Collapse of RCC Structure Due to Earthquake and Wind Load
IRJET-  Progressive Collapse of RCC Structure Due to Earthquake and Wind LoadIRJET-  Progressive Collapse of RCC Structure Due to Earthquake and Wind Load
IRJET- Progressive Collapse of RCC Structure Due to Earthquake and Wind LoadIRJET Journal
 
SEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABS
SEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABSSEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABS
SEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABSIRJET Journal
 
Seismic and progressive collapse mitigation of shear energy dissipation beam ...
Seismic and progressive collapse mitigation of shear energy dissipation beam ...Seismic and progressive collapse mitigation of shear energy dissipation beam ...
Seismic and progressive collapse mitigation of shear energy dissipation beam ...IRJET Journal
 
IRJET- Study of Behavior Parameters of the Building with Variations in Story ...
IRJET- Study of Behavior Parameters of the Building with Variations in Story ...IRJET- Study of Behavior Parameters of the Building with Variations in Story ...
IRJET- Study of Behavior Parameters of the Building with Variations in Story ...IRJET Journal
 
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET Journal
 
ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...
ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...
ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...IRJET Journal
 
COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...
COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...
COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...IRJET Journal
 
Modelling and Analysis of Pile Foundation
Modelling and Analysis of Pile FoundationModelling and Analysis of Pile Foundation
Modelling and Analysis of Pile FoundationIRJET Journal
 

Similar to IRJET- Effect of Viscous Dampers on Response Reduction Factor for RCC Frame using Response Spectrum Analysis (20)

SEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDING
SEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDINGSEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDING
SEISMIC ANALYSIS OF HYBRID STRUCTURAL CONTROL SYSTEM IN RC BUILDING
 
IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...
IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...
IRJET- A Review Paper on Comparative Study of Fixed Base, Base Isolation & Da...
 
Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...
Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...
Seismic Response Study and Evaluation of Vibration Control of High- Rise Stru...
 
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
 
IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...
IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...
IRJET- Effect of Lateral Load on Moment Resisting Frame and Shear Wall in Mul...
 
Comparative Study on Seismic Behavior of Different Shape of RC Structure with...
Comparative Study on Seismic Behavior of Different Shape of RC Structure with...Comparative Study on Seismic Behavior of Different Shape of RC Structure with...
Comparative Study on Seismic Behavior of Different Shape of RC Structure with...
 
Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...
Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...
Analysis of Moment Resisting Reinforced Concrete Frames for Seismic Response ...
 
IRJET- Seismic Evaluation of Reinforced Concrete Structure with Friction ...
IRJET-  	  Seismic Evaluation of Reinforced Concrete Structure with Friction ...IRJET-  	  Seismic Evaluation of Reinforced Concrete Structure with Friction ...
IRJET- Seismic Evaluation of Reinforced Concrete Structure with Friction ...
 
IRJET- Non Linear Static Analysis of Frame with and without Infills
IRJET- Non Linear Static Analysis of Frame with and without InfillsIRJET- Non Linear Static Analysis of Frame with and without Infills
IRJET- Non Linear Static Analysis of Frame with and without Infills
 
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
Seismic Analysis of Fixed Base and Base Isolated RC Buildings Having Diaphrag...
 
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...
COMPARATIVE ANALYSIS OF MULTISTORY BUILDING WITH AND WITHOUT SHEAR WALL, X BR...
 
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
 
IRJET- Progressive Collapse of RCC Structure Due to Earthquake and Wind Load
IRJET-  Progressive Collapse of RCC Structure Due to Earthquake and Wind LoadIRJET-  Progressive Collapse of RCC Structure Due to Earthquake and Wind Load
IRJET- Progressive Collapse of RCC Structure Due to Earthquake and Wind Load
 
SEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABS
SEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABSSEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABS
SEISMIC EVALUATION OF MULTISTORIED BUILDING WITH FLOATING COLUMNS USING ETABS
 
Seismic and progressive collapse mitigation of shear energy dissipation beam ...
Seismic and progressive collapse mitigation of shear energy dissipation beam ...Seismic and progressive collapse mitigation of shear energy dissipation beam ...
Seismic and progressive collapse mitigation of shear energy dissipation beam ...
 
IRJET- Study of Behavior Parameters of the Building with Variations in Story ...
IRJET- Study of Behavior Parameters of the Building with Variations in Story ...IRJET- Study of Behavior Parameters of the Building with Variations in Story ...
IRJET- Study of Behavior Parameters of the Building with Variations in Story ...
 
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
 
ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...
ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...
ADEQUACY OF BELT-TRUSS AND OUTRIGGER SYSTEMS WITH VISCOUS DAMPER IN 3D RC FRA...
 
COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...
COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...
COMPARITIVE ANALYSIS OF RCC STRUCTURE ON SLOPING GROUND AGAINST SEISMIC LOADI...
 
Modelling and Analysis of Pile Foundation
Modelling and Analysis of Pile FoundationModelling and Analysis of Pile Foundation
Modelling and Analysis of Pile Foundation
 

More from IRJET Journal

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...IRJET Journal
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTUREIRJET Journal
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...IRJET Journal
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsIRJET Journal
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...IRJET Journal
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...IRJET Journal
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...IRJET Journal
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...IRJET Journal
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASIRJET Journal
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...IRJET Journal
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProIRJET Journal
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...IRJET Journal
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemIRJET Journal
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesIRJET Journal
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web applicationIRJET Journal
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...IRJET Journal
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.IRJET Journal
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...IRJET Journal
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignIRJET Journal
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...IRJET Journal
 

More from IRJET Journal (20)

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web application
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
 

Recently uploaded

VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝soniya singh
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Dr.Costas Sachpazis
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 

Recently uploaded (20)

VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
 
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
Model Call Girl in Narela Delhi reach out to us at 🔝8264348440🔝
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
Structural Analysis and Design of Foundations: A Comprehensive Handbook for S...
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINEDJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 

IRJET- Effect of Viscous Dampers on Response Reduction Factor for RCC Frame using Response Spectrum Analysis

  • 1. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3597 EFFECT OF VISCOUS DAMPERS ON RESPONSE REDUCTION FACTOR FOR RCC FRAME USING RESPONSE SPECTRUM ANALYSIS Miss Shital D. Zolekar1, Prof. A. V. Sagade2 1P. G. Student, Department of Civil Engineering, Trinity College of Engineering & Research, Pune, Maharashtra, India 2Assistant Professor, Department of Civil Engineering, Trinity College of Engineering & Research, Pune, Maharashtra, India ---------------------------------------------------------------------***---------------------------------------------------------------------- Abstract - Response reduction factor (R) is the parameter which represents the capacity of structure to dissipate energy through inelastic behavior. Increased value of response reduction factor for a structure resembles increased inelasticity of the structure towards seismic forces. Viscous damper is a device which is installed in the structures todamp seismic forces by energy dissipation. Responsereduction factor (R) is a seismic design parameter which determines nonlinear behaviour of RCC structuressubjectedtoearthquake. From the literature review it is seen that the study on the effect of viscous dampers on the response reduction factor (R) is lagging. Thus, the effect of viscous dampers on the response reduction factor (R) of reinforcedconcretestructuresinstalled with viscous dampers has been studied. Overstrength, redundancy and ductility factors are the parameters, used to formulate response reduction factor (R). The performance of reinforced concrete structures in seismic conditions is improved by damping action of viscous dampers. ETABS 2016 software was used to determine the effect of viscous dampers on the behaviour of reinforced concrete building installed with dampers on different locations of the building and at various storeys of building. The effect of nonlinear viscous damper on overstrength, ductilityandresponsereductionfactorofspecial moment resisting frame (SMRF) frames is also studied. The results of the analysis showed that, the value of response reduction factor (R) for reinforced concrete building installed with dampers was higher than the building without damper. Key Words: Response Reduction Factor, Viscous Damper, Ductility Factor, Overstrength Factor, Redundancy Factor, Dynamic Analysis. 1. INTRODUCTION The main purpose & intention of conventional structural design for the structures in seismic zones is human life protection. To serve the intended purpose,itisnecessaryfor the structure to refrain collapse, even though highly damaged by the seismic action. This is the basic concept of the ductility of structure. Response reduction factor for any structure represents ductility and the same is incorporated in the design of structure through responsereductionfactor. The response reduction factor (R) is a seismic design parameter that determines the nonlinear performance of building structuresduringstrong earthquakes.Thestructure may loose all its functionality (partial / complete) after seismic actions. Retrofitting of such structures affected by earthquakes may become very intricate or even impossible in some cases. In order to reduce the deleterious effects of earthquakes on the stability of structures, it is necessary to mitigate the effect of seismic action on the structure by providing a catalyst in structure. This can be achieved by providing an emerging technology known as viscous dampers. Viscous dampers functions on the principle of passive energy dissipation by adding damping of seismic forces in the structure. Previous study on response of structure to earthquakes provided with viscous damper shows that it can reduce storydrift,forcesin memberswhich leads to less damage to structure enabling it to resist large lateral force. It is very important to safeguard the structures such as airports, fire department barracks, nuclear power plants, communication centers, hospitals, bus stops, institutions etc from the earthquakes to reachhigherlevel of safety. By the virtue of damping action of viscousdampers,it reduces forces in the members,enablingprovisionofsmaller cross sections of structural members. This makes the construction of the structure more cost efficient and light weight which favours response of structure against seismic action. 2. RESPONSE REDUCTION FACTOR Response reduction factor determines level of inelasticityof structure expected in lateral structural systems during an earthquake. The concept of R is based on assumption that the well detailed seismic framing system can sustain large inelastic deformations without collapse. Calculation of design base shear is as given below (IS 1893), The definition of response reductionisintroducedbyATC19 (1995) in the form of equation as shown below, Where R is response reduction factor, is over strength factor, is ductility factor, isredundancyfactorand is damping factor.
  • 2. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3598 Effects of added damping is ratiocinated by documents such as ATC (1995) damping to reduce the force response of buildings. Equation of response reduction appeared in various literatures is as shown below, 2.1 Overstrength Factor ( ) Overstrength factor determines the yielding of structure at higher load than design load because of various factors like partial load factors appliedtogravityloadsandsafetyfactors applied to material strengths. It is represented intheform of equation as shown below, Where Vd is the design base shear force in the building calculated (IS 1893:2002) & Vy is the yield base shear force that corresponds to actual yielding of structure. 2.2 Ductility Factor (Rµ) The ductility factor ( ) determines nonlinear response ofa structure that occurs from hysteretic energy. It reduces the elastic force demand to the level of idealized yield strength of the structure Ductility factor was developed by Newmark and Hall (1982) as follows, Rμ = 1 for T < 0.2 s Rμ = for 0.2 s < T < 0.5 s Rμ = μ for T > 0.5 s 𝜇 = 2.3 Redundancy Factor (Rr) The redundancy factor (Rr) is a measure of repetitions in a lateral load resisting system. The moment resisting frames, shear walls or their aggregates are the most chosen lateral load resisting systems in RC structures.ASCE7recommends a redundancy factor Rr = 1.0 forsystemswithparallel frames and the corresponding is adopted for this work as the case study structures fall in this category. Table – 1: Redundancy factor (Rr) from ATC Lines of vertical framing Drift Redundancy factor 2 0.71 3 0.86 4 1.0 2.3 Fluid Viscous Dampers (FVD) The primary aim of energy dissipation devices is to mitigate displacement of the structures due to earthquakes. Energy dissipation is better alternative to conventional stiffening and strengthening schemes and would be expected to achieve comparable performance levels. Fluid viscous dampers were initially used in the military and aerospace industry. They were used in structural engineering in the late 1980’s and early 1990’s. Fluid viscous dampers consists of a piston head with orifices contained in a cylinder filled with a highly viscous fluid, usually a compound of silicone or a similar type of oil. Energy is dissipated in the damper by fluid orificing when the piston head moves throughthefluid. The fluid in the cylinder is nearly incompressible and when the damper is subjected to a compressive force, the fluid volume inside the cylinder is decreased as a result of the piston rod area movement. A decrease in volume resultsina restoring force. This force is undesirable and is usually prevented by using a run-through rod that enters, the damper is connected to the piston head and then passes out the other end of the damper. Another method forpreventing the restoring force is to use an accumulator. An accumulator works by collecting the volume of fluid that is displaced by the piston rod and storing it in the make-up area. As the rod retreats, a vacuum that has been created will draw the fluid out. A damper with an accumulator is illustrated in fig. 1. Fig – 1: Fluid Viscous Damper (FVD) Fluid viscous dampers have the unique advantage of reducing the shearing and bendingstresses atthesametime, as the velocity-dependent maximum damping force is 90 degrees out of phase with the maximum deflection of the structure. In addition, installing FVDs in a structuredoesnot alter its force displacement relationship. 3. STRUCTURAL MODELLING RCC buildings of 4, 8, 12 and 16 storey, symmetric in plan are considered in present study. To represent the effect of time period on response structure, structures with various storey were considered. It had 3 bays in both the directions with bay width of 6 m. The height of all stories was taken as 3 m. The seismic forces on these buildings were determined as per IS 1893:2002. These RC buildings were designed for
  • 3. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3599 both gravity and earthquake forces based on guidelines given by IS 456:2000 and IS 13920:1993. Fig – 2: Structural arrangement of four buildings in plan The data used for design is as follows: Table – 2: Material Properties Storey Grade of concrete Grade of steel 4 M20 Fe 500 8 M25 Fe 500 12 M30 Fe 500 16 M30 Fe 500  Imposed load for Institutional structureis3kN/ .  Floor finish load is 1.5 kN/ .  Wall load on beams are assumed as 12 kN/m for outer walls and 6 kN/m for inner walls.  Floor slabs are assumed as 200 mm thick.  Damping coefficient 770 kNs/m.  Building frame is modeled as rigid jointed frame i.e. Special moment resisting frame. Table – 3: Properties of Fluid Viscous Damper Sr. No Damping coefficient (kNs/m) Force (kN) Stiffness (kN/m) Mass (kg) 1. 770.0 733.9 3850000 150 2. 1027.4 978.6 5137050 215 3. 1541.1 1467.9 7705000 300 4. 2054.8 1957.2 10274000 450 Details of models considered in present study are discussed below. In configuration I (CONFI-I), viscous dampers are added in middle bays of frame and in configuration II (CONFI-II), viscous dampers are added in corner bay but i.e. different location of frame through overall height of structure. I. 4 storey building (a) (b) (c) (a) Structure without damper; (b) Structure with damper CONFI-I; (c) Structure with damper CONFI-II Fig – 3: 4 storey RCC building with different damper configurations II. 8 storey building (a) (b) (c) (a) Structure without damper; (b) Structure with damper CONFI-I; (c) Structure with damper CONFI-II Fig - 4: 8 storey RCC building with different damper configurations
  • 4. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3600 III. 12 storey building (a) (b) (C) (a) Structure without damper; (b) Structure with damper CONFI-I; (c) Structure with damper CONFI-II Fig – 5: 12 storey RCC building with different damper configurations IV. 16 storey building (a) (b) (c) (a) Structure without damper; (b) Structure with damper CONFI-I; (c) Structure with damper CONFI-II Fig – 6: 16 storey RCC building with different damper configurations Table - 4: Details of RC section Building Floor Column(mm) Beam(mm) 4 storey 1-2 500x500 230x450 3-4 450x450 230x450 8 storey 1-5 650x650 300x500 6-8 500x500 300x500 12 storey 1-4 750x750 300x600 5-8 650x650 300x600 9-12 550x550 300x600 16 storey 1-4 850x850 300x600 5-8 750x750 300x600 9-12 650x650 300x600 13-16 550x550 300x600 4. SEISMIC ANALYSIS Seismic analysis is a subset of structural analysis and is the calculation of the response of a building structure to earthquakes. It is part of the process of structural design, earthquake engineering or structural assessment and retrofit in regions where earthquakes are prevalent. The behaviour of structure, external action, and the kind of structural design selected, is the key to this analysis.Also,on the basis of the behavior of the structureand external action, the analysis is further categorized as (i) Linear Static Analysis, (ii) Nonlinear Static analysis, (iii) Linear Dynamic analysis, and (iv) Nonlinear Dynamic analysis.
  • 5. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3601 Table – 5: Response reduction factor for 4 Storey building G+3 Storey (mm) (mm) R Without FVD 984.421 949.680 1.0366 48 17.94 2.0860 1 2.1623 With FVD CONFI-I 985.542 950.961 1.0364 48 13.12 2.5130 1 2.6044 With FVD CONFI-II 985.542 950.961 1.0364 48 13.76 2.5543 1 2.5972 Table - 5: Response reduction factor for 8 Storey building G+7 Storey (mm) (mm) R Without FVD 2203.277 2116.423 1.0410 96 46.62 2.0593 1 2.1438 With FVD CONFI-I 2205.679 2118.985 1.0409 96 33.81 2.8394 1 2.9556 With FVD CONFI-II 2205.679 2118.985 1.0409 96 34.09 2.8158 1 2.9310 Table – 6: Response reduction factor for G+11 Storey building 12 Storey (mm) (mm) R Without FVD 2477.673 3338.171 0.7422 144 51.93 2.7732 1 2.0583 With FVD CONFI-I 2480.297 3342.015 1.0419 144 40.11 3.5898 1 3.7400 With FVD CONFI-II 2480.297 3342.015 1.0419 144 41.22 3.4939 1 3.6401 Table - 7: Response reduction factor for G+15 Storey building 16 Storey (mm) (mm) R Without FVD 2536.220 4554.324 0.5569 192 69.81 2.7505 1 1.5317 With FVD CONFI-I 2538.873 4559.448 1.0423 192 51.99 3.6932 1 3.8493 With FVD CONFI-II 2538.873 4559.448 1.0423 192 54.06 3.5514 1 3.7015 Table – 8: Comparison of response reduction factor without viscous dampers, with viscous dampers Configuration I & with viscous dampers Configuration II Storey Without Damper With FVD CONFI. I With FVD CONFI. II Values of R 4 2.1623 2.6044 2.5972 8 2.1438 2.9556 2.9310 12 2.0583 3.7400 3.6401 16 1.5317 3.8493 3.7015
  • 6. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 07 | July 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3602 Fig – 7: Response Reduction Factor 6. CONCLUSIONS Following are the conclusions of the study: 1. A constant value of R for any case of building cannot be justified. Well-defined methods are requiredtofindout the R value accounting for strength, ductility, redundancy and damping for any particular building; present work takes efforts in the same line of action. 2. It is observed that implementation of viscous dampers reduce the storey displacement, drift, acceleration occurred in RCC building and increases the base shear capacity. 3. R factors computed are highly dependent on the height of building, viscous damper capacity and the input ground motion. 4. Buildings with dampers can resist more lateral loads compared to building without damper at nearly same displacement. 5. For this study, R factor for buildingwithConfigurationI and II increases as height of building increases. 6. The advantage of viscous dampers is clearly demonstrated by increase in response reduction factor and improvement in performance of the building during an earthquakehasbeenproven.Therefore,FVDs are effective for enhancement of RCC buildings performance when subjected to dynamic excitations. 7. It is observed that overstrength factor slightly decreases with increase in damping capacity and also ductility factor is increased in building with increase in capacity of dampers. 8. It is observed that ductility factor is increased in building with dampers. 7. REFERENCES A. Mondal, G .Siddhartha and G. Reddy (2013), “Performance-based evaluation of the response reduction factor for ductile RC frames”, Journal of Engineering Structures, Vol. 56,pp. 1808-1819. A. Whittaker, G. Hart and C. Rojahn (1999),Seismicresponse modification factors. Journal of Structural Engineering. Vol. 125, no. 4, pp. 438-444. F. Hejazi, J. Noorzaei, M. Jaafar and A. Abang Abdullah (2009), “Earthquake Analysis of Reinforce ConcreteFramed Structures with Added Viscous Dampers”, International Journal of Applied Science, EngineeringandTechnology,Vol. 65, pp. 284-293. H. Abdi, F. Hejazi, R. Saifulnaz, I. Karim and M. Jaafar (2015), “Response Modification Factor for Steel Structure Equipped with Viscous Damper Device”, International Journal of Steel Structures, Vol. 15, no. 3 pp. 605-622. J. Hwang, Y. Huang, S. Lian Yi and S. Yen Ho (2012), “Design Formulations for Supplemental ViscousDamperstoBuilding Structures”, Journal of Structural Engineering,Vol.131,no.1, pp.22-34. M. ConstantinouandM.Symans(1993),“Experimental Study of Seismic Response ofBuildings with Supplemental Fluid Dampers”, The Structural Design of Tall Buildings, Vol. 2,pp. 93-132. Mohsen Kargahi andChukwuma G. Ekwueme (2004), “Optimization of ViscousDamperPropertiesforReductionof Seismic Risk in Concrete Buildings”, 13th World Conference on Earthquake Engineering, Paper No. 1027. Oscar M. Ramirez, Michael C. Constantinou, Charles A. Kircher, Andrew S. Whittaker,Martin W. JohnsonandJuan D. Gomez (2000), “Development and Evaluation of Simplified Procedures for Analysis andDesignofBuildingswithPassive Energy Dissipation Systems”, Technical Report MCEER-00- 0010, University at Buffalo, State University of New York Department of Civil, Structural and Environmental Engineering Ketter Hall Buffalo, NY 14260.