SlideShare a Scribd company logo
1 of 35
A SEMINAR REPORT ON
THE PRINCIPLES & APPLICATIONS
OF RADIOISOTOPES.
By Abhishek .A. Giri
M.Sc. (part-I)
Roll no. 1326056
Paper - IV , Unit - II
A PRESENTATION ON
THE PRINCIPLES & APPLICATIONS
OF RADIOISOTOPES.
By Abhishek .A. Giri
Topic to cover:-
 What are radioisotopes?
 Uses of radioisotopes
 Units of radioactivity
 Method of scintillation counting
 Autoradiography
o An isotope is one of two or more atoms having the same atomic
number but different mass numbers.
o Unstable isotopes are called Radioisotopes.
o When an unstable nucleus disintegrates into more stable one radiations
are emitted.
o They become stable isotopes by the process of radioactive decay.
What is a Radioisotope?
1) It is possible to detect radioactivity with exquisite sensitivity.
2) it is possible to follow what happens in time.
3) it is possible to trace what happens to individual atoms in a pathway.
4) we can identify a part or end of a molecule , & follow it very precisely.
Why do we use Radioisotope?
1. MEDICALTRACERS 2. STERILISATION
3. STERILZING FOOD
Uses of radioisotopes
UNSTERILIZED
Gamma source
STERILIZED
o The original unit for measuring the amount of radioactivity was the curie
(Ci)- first defined to correspond to one gram of radium – 226
& more recently defined as : 1 Curie = 3.7x1010 radioactive decays/sec .
o In SI unit the curie has been replaced by becquerel (Bq), where
1 becquerel = 1 radioactive decay per second = 2.703x10-11 Ci .
Units of Radioactivity
DETECTION & MEASUREMENT OF
RADIOACTIVITY
o There are three commonly used methods of detecting & quantifying
radioactivity.
o These are based on the ionization of gases, on the excitation of solids or
solutions, & the ability of radioactivity to expose photographic emulsions
(i.e. autoradiography)
o Gaseous ionization detectors are radiation detection instruments used in
radiation protection applications to measure ionizing radiation.
o They use the ionizing effect of radiation upon a gas-filled sensor.
o Particle having enough energy to ionize a gas molecule, the resulting
electrons & ions cause a current flow which can be measured.
Method based upon Gas ionization
o The three types of gaseous ionization detectors are:
1. Ionization chambers
2. Proportional counters
3. Geiger-Muller tubes
Types
Ionization chambers
Operate at a low electric field strength
The ion current is generated by the creation of ‘ion pairs’.
The +ve ions drift to the cathode whilst free electrons drift to the anode
under the influence of the electric field.
o Good uniform response to gamma radiation and give an accurate overall
dose reading
o Will measure very high radiation rates
o Sustained high radiation levels do not degrade fill gas
Advantages
o Very low electronic output requiring sophisticated electrometer circuit
o Operation and accuracy easily affected by moisture
o Cannot measure energy of radiation - no spectrographic information
Disadvantages
Proportional Counter
Proportional counters operate at a slightly higher voltage.
Each ion pair produces a single avalanche so that an output current pulse is
generated which is proportional to the energy deposited by the radiation.
This is “prortional counting” region.
o Can measure energy of radiation and provide spectrographic
information
o Can discriminate between alpha and beta particles
o Large area detectors can be constructed
Advantages
o Anode wires delicate and can lose efficiency in gas flow detectors due to
deposition
o Efficiency and operation affected by ingress of oxygen into fill gas
o Measurement windows easily damaged in large area detectors
Disadvantages
Geiger-Muller Tube
o They operate at a very higher voltage, selected that each ion pair creates
an avalanche, but by the emission of UV photons, multiple avalanches
are created which spread along the anode wire, and the adjacent gas
volume ionizes from as little as a single ion pair event.
o This is the "Geiger region" of operation.
o The current pulses produced by the ionising events are passed to
processing electronics which can derive a visual display of count rate or
radiation dose, and usually in the case of hand-held instruments, an
audio device producing clicks.
Cheap, robust detector with a large variety of sizes and applications
Large output signal from tube requiring minimal electronic processing for
simple counting
Can measure overall gamma dose when using energy compensated tube
Advantages
Cannot measure energy of radiation - no spectrographic information
Will not measure high radiation rates due to dead time
Sustained high radiation levels will degrade fill gas
Disadvantages
Radioactive isotopes interact with matter in two ways, ionisation &
excitation.the latter effects leads an excited atom or compound (fluor) to
emit photons of light.This process is known as Scintillation.
When the light is detected by a photomultiplier converts the energy of
radiation into an electrical signal, & the strenght of the electric pulse that
results is directly proportional to the energy of the original radioactive
event.
Method based upon Excitation
SCINTILLATION COUNTER
A scintillation counter is an instrument for detecting and
measuring ionizing radiation.
It consists of a scintillator which generates photons of light in response
to incident radiation, a sensitive photomultiplier tube which converts
the light to an electrical signal, and the necessary electronics to process
the photomultiplier tube output.
operation
When a charged particle strikes the scintillator, its atoms are excited and
photons are emitted.
These are directed at the photomultiplier tube's photocathode, which emits
electrons by the photoelectric effect.
These electrons are electrostatically accelerated and focused by an
electrical potential .
The scintillator must be in complete darkness so that visible light photons
do not swamp the individual photon events caused by incident ionising
radiation.
Schematic of a scintillating crystal combined with a
photomultiplier.
Fluroscence is very fast so there is no dead time.
Counting efficiences are high .
Ability to count samples of many types like liquid, solids & gels.
Highly automated.
Advantages
Cost of the instrument & cost per sample.
Potentially high background noise.
Quenching
Chemiluminescence
phospholuminescence
disadvatages
Scintillation counters are used to measure radiation in a variety of
applications.
o Hand held radiation survey meters
o Personnel and environmental monitoring for Radioactive
contamination.
o Medical imaging.
o National and homeland security.
o Border security.
o Nuclear plant safety.
o Oil well lodging.
Applications
AUTORADIOGRAPHY
Radiography is the visualisation of the pattern of distribution of radiation.
In general, the radiation consists of X-rays, gamma (g ) or beta (b ) rays,
and the recording medium is a photographic film.
In contrast, in autoradiography the specimen itself is the source of the
radiation, which originates from radioactive material incorporated into it.
• Living cells are briefly exposed to a ‘pulse’ of a specific radioactive
compound.
• Samples are taken, fixed, and processed for light or electron
microscopy.
• Left in the dark for days or weeks (while the radioisotope decays).
• The photographic emulsion is developed (as for conventional
photography).
• Counterstaining .
• Alternatively, pre-staining of the entire block of tissue can be done.
• It is not necessary to coverslip these slides
• The position of the silver grains in the sample is observed by light or
electron microscopy .
• These autoradiographs provide a permanent record.
• Full details on the batch of emulsion used, dates, exposure time and
conditions should be kept for each experiment.
Autoradiography Method
Radioisotopes by D. Billington,G. Jayson
Principles & techniques in practical biochemistry by KeithWilson, John
walker
Principles & techniques of Biochemistry & molecular biology by R.J.Slater
www.ansto.gov.au/NuclearFacts/.../Radioisotopes/index.htm
www.kentchemistry.com/links/Nuclear/radioisotopes.htm
www.lab.anhb.uwa.edu.au/hb313/main_pages/.../autoradiography.htm
www.wikipedia.org/wiki/Liquid_scintillation_counting
References

Thank you

More Related Content

What's hot

Spectrophotometer
SpectrophotometerSpectrophotometer
Spectrophotometer
Asad Leo
 
Spectrophotometry: basic concepts, instrumentation and application
Spectrophotometry: basic concepts, instrumentation and applicationSpectrophotometry: basic concepts, instrumentation and application
Spectrophotometry: basic concepts, instrumentation and application
Basil "Lexi" Bruno
 

What's hot (20)

PAGE- Electrophoresis
PAGE- ElectrophoresisPAGE- Electrophoresis
PAGE- Electrophoresis
 
Flow cytometry
Flow cytometryFlow cytometry
Flow cytometry
 
Differential centrifugation
Differential centrifugationDifferential centrifugation
Differential centrifugation
 
Fluorescence microscope
Fluorescence microscopeFluorescence microscope
Fluorescence microscope
 
Spectrophotometer
SpectrophotometerSpectrophotometer
Spectrophotometer
 
Radioisotopes in biological system
Radioisotopes in biological systemRadioisotopes in biological system
Radioisotopes in biological system
 
Autoradiography
AutoradiographyAutoradiography
Autoradiography
 
Fluorescence Microscopy
Fluorescence MicroscopyFluorescence Microscopy
Fluorescence Microscopy
 
Phase contrast & Flurosence microscope
Phase contrast & Flurosence microscopePhase contrast & Flurosence microscope
Phase contrast & Flurosence microscope
 
Colorimetry
ColorimetryColorimetry
Colorimetry
 
Spectrophotometry
SpectrophotometrySpectrophotometry
Spectrophotometry
 
Sds-Page
Sds-Page Sds-Page
Sds-Page
 
Autoradiography
AutoradiographyAutoradiography
Autoradiography
 
Fplc(fast protein liquid chromatography )
Fplc(fast protein liquid chromatography )Fplc(fast protein liquid chromatography )
Fplc(fast protein liquid chromatography )
 
Spectrophotometer
SpectrophotometerSpectrophotometer
Spectrophotometer
 
MALDI-TOF Mass Spectrometry
MALDI-TOF Mass SpectrometryMALDI-TOF Mass Spectrometry
MALDI-TOF Mass Spectrometry
 
Electron microscope, principle and application
Electron microscope, principle and applicationElectron microscope, principle and application
Electron microscope, principle and application
 
Spectrophotometry: basic concepts, instrumentation and application
Spectrophotometry: basic concepts, instrumentation and applicationSpectrophotometry: basic concepts, instrumentation and application
Spectrophotometry: basic concepts, instrumentation and application
 
Principles and application of light, phase constrast and fluorescence microscope
Principles and application of light, phase constrast and fluorescence microscopePrinciples and application of light, phase constrast and fluorescence microscope
Principles and application of light, phase constrast and fluorescence microscope
 
Centrifugation and types of rotors
Centrifugation and types of rotorsCentrifugation and types of rotors
Centrifugation and types of rotors
 

Viewers also liked

Radioactive Tracers
Radioactive TracersRadioactive Tracers
Radioactive Tracers
Lordxsempre
 
X Rays Ppt
X Rays PptX Rays Ppt
X Rays Ppt
shas595
 

Viewers also liked (12)

Chronic Stable Angina- Diagnosis & management
Chronic Stable Angina- Diagnosis & managementChronic Stable Angina- Diagnosis & management
Chronic Stable Angina- Diagnosis & management
 
CT scan
CT scanCT scan
CT scan
 
Radioactive isotopes
Radioactive isotopesRadioactive isotopes
Radioactive isotopes
 
History of echocardiography
History of echocardiographyHistory of echocardiography
History of echocardiography
 
Radioactive Tracers
Radioactive TracersRadioactive Tracers
Radioactive Tracers
 
Spect technology
Spect technologySpect technology
Spect technology
 
Tracer technique
Tracer techniqueTracer technique
Tracer technique
 
Secondary metabolites
Secondary metabolitesSecondary metabolites
Secondary metabolites
 
Ophthalmic ultrasound
Ophthalmic ultrasoundOphthalmic ultrasound
Ophthalmic ultrasound
 
X rays
X raysX rays
X rays
 
X Rays Ppt
X Rays PptX Rays Ppt
X Rays Ppt
 
Computer Tomography (CT Scan)
Computer Tomography (CT Scan)Computer Tomography (CT Scan)
Computer Tomography (CT Scan)
 

Similar to Radioisotope technique and methods

RADIATION DETECTION AND MEASUREMENT ppt 2.pptx
RADIATION DETECTION AND MEASUREMENT ppt 2.pptxRADIATION DETECTION AND MEASUREMENT ppt 2.pptx
RADIATION DETECTION AND MEASUREMENT ppt 2.pptx
Srinath Chowdary
 

Similar to Radioisotope technique and methods (20)

Prabhakar singh ii sem-paper v-detection & measurement of radioactivity
Prabhakar singh  ii sem-paper v-detection & measurement of radioactivityPrabhakar singh  ii sem-paper v-detection & measurement of radioactivity
Prabhakar singh ii sem-paper v-detection & measurement of radioactivity
 
Ultraviolet and visible spectroscopy
Ultraviolet and visible  spectroscopyUltraviolet and visible  spectroscopy
Ultraviolet and visible spectroscopy
 
SOLID SCINTILLATION WRITE UP.docx
SOLID SCINTILLATION WRITE UP.docxSOLID SCINTILLATION WRITE UP.docx
SOLID SCINTILLATION WRITE UP.docx
 
Spectroscopy
SpectroscopySpectroscopy
Spectroscopy
 
Gamma ray spectroscopy
Gamma ray spectroscopyGamma ray spectroscopy
Gamma ray spectroscopy
 
Nuclear i nstrumentation
Nuclear i nstrumentationNuclear i nstrumentation
Nuclear i nstrumentation
 
Radiation Detection Principles.pptx
Radiation Detection Principles.pptxRadiation Detection Principles.pptx
Radiation Detection Principles.pptx
 
Uv visible spectroscopy
Uv visible spectroscopyUv visible spectroscopy
Uv visible spectroscopy
 
Spectropotometer.08.20 - Copy.ppt
Spectropotometer.08.20 - Copy.pptSpectropotometer.08.20 - Copy.ppt
Spectropotometer.08.20 - Copy.ppt
 
RADIATION DETECTION AND MEASUREMENT ppt 2.pptx
RADIATION DETECTION AND MEASUREMENT ppt 2.pptxRADIATION DETECTION AND MEASUREMENT ppt 2.pptx
RADIATION DETECTION AND MEASUREMENT ppt 2.pptx
 
upload RADIATION DETECTION AND MEASUREMENT.pptx
upload RADIATION DETECTION AND MEASUREMENT.pptxupload RADIATION DETECTION AND MEASUREMENT.pptx
upload RADIATION DETECTION AND MEASUREMENT.pptx
 
Spectroscopy.pptx
Spectroscopy.pptxSpectroscopy.pptx
Spectroscopy.pptx
 
U.V Spectroscopy
U.V SpectroscopyU.V Spectroscopy
U.V Spectroscopy
 
UNIT 5.pptx
UNIT 5.pptxUNIT 5.pptx
UNIT 5.pptx
 
Uv/visible spectroscopy
Uv/visible spectroscopyUv/visible spectroscopy
Uv/visible spectroscopy
 
Uv
UvUv
Uv
 
UV-Visible Spectrophotometer
UV-Visible SpectrophotometerUV-Visible Spectrophotometer
UV-Visible Spectrophotometer
 
INSTRUMENTATIONS UV-VIS.pdf
INSTRUMENTATIONS UV-VIS.pdfINSTRUMENTATIONS UV-VIS.pdf
INSTRUMENTATIONS UV-VIS.pdf
 
Niab 2016
Niab 2016Niab 2016
Niab 2016
 
Radio isotope
Radio isotopeRadio isotope
Radio isotope
 

More from University of Mumbai

More from University of Mumbai (16)

Aminoglycosides and their uses.
Aminoglycosides and their uses.Aminoglycosides and their uses.
Aminoglycosides and their uses.
 
Morphometric measurement of fishes
Morphometric measurement of fishesMorphometric measurement of fishes
Morphometric measurement of fishes
 
El nino - The arrival of Warm water
El nino - The arrival of Warm waterEl nino - The arrival of Warm water
El nino - The arrival of Warm water
 
Fungal Transformation - dna transformation in fungi
Fungal Transformation - dna transformation in fungiFungal Transformation - dna transformation in fungi
Fungal Transformation - dna transformation in fungi
 
immobilized Enzyme reactors- batch and continuous types.
immobilized Enzyme reactors- batch and continuous types. immobilized Enzyme reactors- batch and continuous types.
immobilized Enzyme reactors- batch and continuous types.
 
Lobster and crab fisheries in INDIA
Lobster and crab fisheries in INDIALobster and crab fisheries in INDIA
Lobster and crab fisheries in INDIA
 
Major and minor components of seawater
Major and minor components of seawaterMajor and minor components of seawater
Major and minor components of seawater
 
Random Amplified polymorphic DNA. RAPD
Random Amplified polymorphic DNA. RAPDRandom Amplified polymorphic DNA. RAPD
Random Amplified polymorphic DNA. RAPD
 
Maximizing the efficiency of fermentation process
Maximizing the efficiency of fermentation processMaximizing the efficiency of fermentation process
Maximizing the efficiency of fermentation process
 
Polyacrylamide gel electrophoresis
Polyacrylamide gel electrophoresisPolyacrylamide gel electrophoresis
Polyacrylamide gel electrophoresis
 
Aging- the biology of senescence
Aging- the biology of senescenceAging- the biology of senescence
Aging- the biology of senescence
 
Amino acids- the building blocks of proteins
Amino acids- the building blocks of proteinsAmino acids- the building blocks of proteins
Amino acids- the building blocks of proteins
 
Birds as glorified reptiles
Birds as glorified reptilesBirds as glorified reptiles
Birds as glorified reptiles
 
Giant chromosomes-lampbrush & Polytene
Giant chromosomes-lampbrush & Polytene Giant chromosomes-lampbrush & Polytene
Giant chromosomes-lampbrush & Polytene
 
A presentation on Economic importance of protozoan
A presentation on Economic importance of protozoanA presentation on Economic importance of protozoan
A presentation on Economic importance of protozoan
 
A complete PPT on DNA
A complete PPT on DNA A complete PPT on DNA
A complete PPT on DNA
 

Recently uploaded

Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
kauryashika82
 
Gardella_PRCampaignConclusion Pitch Letter
Gardella_PRCampaignConclusion Pitch LetterGardella_PRCampaignConclusion Pitch Letter
Gardella_PRCampaignConclusion Pitch Letter
MateoGardella
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
QucHHunhnh
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global Impact
PECB
 
Gardella_Mateo_IntellectualProperty.pdf.
Gardella_Mateo_IntellectualProperty.pdf.Gardella_Mateo_IntellectualProperty.pdf.
Gardella_Mateo_IntellectualProperty.pdf.
MateoGardella
 

Recently uploaded (20)

Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in DelhiRussian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
Russian Escort Service in Delhi 11k Hotel Foreigner Russian Call Girls in Delhi
 
PROCESS RECORDING FORMAT.docx
PROCESS      RECORDING        FORMAT.docxPROCESS      RECORDING        FORMAT.docx
PROCESS RECORDING FORMAT.docx
 
Unit-IV; Professional Sales Representative (PSR).pptx
Unit-IV; Professional Sales Representative (PSR).pptxUnit-IV; Professional Sales Representative (PSR).pptx
Unit-IV; Professional Sales Representative (PSR).pptx
 
Advance Mobile Application Development class 07
Advance Mobile Application Development class 07Advance Mobile Application Development class 07
Advance Mobile Application Development class 07
 
Gardella_PRCampaignConclusion Pitch Letter
Gardella_PRCampaignConclusion Pitch LetterGardella_PRCampaignConclusion Pitch Letter
Gardella_PRCampaignConclusion Pitch Letter
 
1029-Danh muc Sach Giao Khoa khoi 6.pdf
1029-Danh muc Sach Giao Khoa khoi  6.pdf1029-Danh muc Sach Giao Khoa khoi  6.pdf
1029-Danh muc Sach Giao Khoa khoi 6.pdf
 
Beyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global ImpactBeyond the EU: DORA and NIS 2 Directive's Global Impact
Beyond the EU: DORA and NIS 2 Directive's Global Impact
 
fourth grading exam for kindergarten in writing
fourth grading exam for kindergarten in writingfourth grading exam for kindergarten in writing
fourth grading exam for kindergarten in writing
 
This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.This PowerPoint helps students to consider the concept of infinity.
This PowerPoint helps students to consider the concept of infinity.
 
Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1Código Creativo y Arte de Software | Unidad 1
Código Creativo y Arte de Software | Unidad 1
 
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
Explore beautiful and ugly buildings. Mathematics helps us create beautiful d...
 
Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...
Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...
Ecological Succession. ( ECOSYSTEM, B. Pharmacy, 1st Year, Sem-II, Environmen...
 
Measures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SDMeasures of Dispersion and Variability: Range, QD, AD and SD
Measures of Dispersion and Variability: Range, QD, AD and SD
 
APM Welcome, APM North West Network Conference, Synergies Across Sectors
APM Welcome, APM North West Network Conference, Synergies Across SectorsAPM Welcome, APM North West Network Conference, Synergies Across Sectors
APM Welcome, APM North West Network Conference, Synergies Across Sectors
 
Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17Advanced Views - Calendar View in Odoo 17
Advanced Views - Calendar View in Odoo 17
 
Gardella_Mateo_IntellectualProperty.pdf.
Gardella_Mateo_IntellectualProperty.pdf.Gardella_Mateo_IntellectualProperty.pdf.
Gardella_Mateo_IntellectualProperty.pdf.
 
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
Presentation by Andreas Schleicher Tackling the School Absenteeism Crisis 30 ...
 
microwave assisted reaction. General introduction
microwave assisted reaction. General introductionmicrowave assisted reaction. General introduction
microwave assisted reaction. General introduction
 
psychiatric nursing HISTORY COLLECTION .docx
psychiatric  nursing HISTORY  COLLECTION  .docxpsychiatric  nursing HISTORY  COLLECTION  .docx
psychiatric nursing HISTORY COLLECTION .docx
 
Nutritional Needs Presentation - HLTH 104
Nutritional Needs Presentation - HLTH 104Nutritional Needs Presentation - HLTH 104
Nutritional Needs Presentation - HLTH 104
 

Radioisotope technique and methods

  • 1. A SEMINAR REPORT ON THE PRINCIPLES & APPLICATIONS OF RADIOISOTOPES. By Abhishek .A. Giri M.Sc. (part-I) Roll no. 1326056 Paper - IV , Unit - II
  • 2. A PRESENTATION ON THE PRINCIPLES & APPLICATIONS OF RADIOISOTOPES. By Abhishek .A. Giri
  • 3. Topic to cover:-  What are radioisotopes?  Uses of radioisotopes  Units of radioactivity  Method of scintillation counting  Autoradiography
  • 4. o An isotope is one of two or more atoms having the same atomic number but different mass numbers. o Unstable isotopes are called Radioisotopes. o When an unstable nucleus disintegrates into more stable one radiations are emitted. o They become stable isotopes by the process of radioactive decay. What is a Radioisotope?
  • 5. 1) It is possible to detect radioactivity with exquisite sensitivity. 2) it is possible to follow what happens in time. 3) it is possible to trace what happens to individual atoms in a pathway. 4) we can identify a part or end of a molecule , & follow it very precisely. Why do we use Radioisotope?
  • 6. 1. MEDICALTRACERS 2. STERILISATION 3. STERILZING FOOD Uses of radioisotopes UNSTERILIZED Gamma source STERILIZED
  • 7. o The original unit for measuring the amount of radioactivity was the curie (Ci)- first defined to correspond to one gram of radium – 226 & more recently defined as : 1 Curie = 3.7x1010 radioactive decays/sec . o In SI unit the curie has been replaced by becquerel (Bq), where 1 becquerel = 1 radioactive decay per second = 2.703x10-11 Ci . Units of Radioactivity
  • 8. DETECTION & MEASUREMENT OF RADIOACTIVITY o There are three commonly used methods of detecting & quantifying radioactivity. o These are based on the ionization of gases, on the excitation of solids or solutions, & the ability of radioactivity to expose photographic emulsions (i.e. autoradiography)
  • 9. o Gaseous ionization detectors are radiation detection instruments used in radiation protection applications to measure ionizing radiation. o They use the ionizing effect of radiation upon a gas-filled sensor. o Particle having enough energy to ionize a gas molecule, the resulting electrons & ions cause a current flow which can be measured. Method based upon Gas ionization
  • 10. o The three types of gaseous ionization detectors are: 1. Ionization chambers 2. Proportional counters 3. Geiger-Muller tubes Types
  • 12. Operate at a low electric field strength The ion current is generated by the creation of ‘ion pairs’. The +ve ions drift to the cathode whilst free electrons drift to the anode under the influence of the electric field.
  • 13. o Good uniform response to gamma radiation and give an accurate overall dose reading o Will measure very high radiation rates o Sustained high radiation levels do not degrade fill gas Advantages
  • 14. o Very low electronic output requiring sophisticated electrometer circuit o Operation and accuracy easily affected by moisture o Cannot measure energy of radiation - no spectrographic information Disadvantages
  • 16. Proportional counters operate at a slightly higher voltage. Each ion pair produces a single avalanche so that an output current pulse is generated which is proportional to the energy deposited by the radiation. This is “prortional counting” region.
  • 17. o Can measure energy of radiation and provide spectrographic information o Can discriminate between alpha and beta particles o Large area detectors can be constructed Advantages
  • 18. o Anode wires delicate and can lose efficiency in gas flow detectors due to deposition o Efficiency and operation affected by ingress of oxygen into fill gas o Measurement windows easily damaged in large area detectors Disadvantages
  • 20. o They operate at a very higher voltage, selected that each ion pair creates an avalanche, but by the emission of UV photons, multiple avalanches are created which spread along the anode wire, and the adjacent gas volume ionizes from as little as a single ion pair event. o This is the "Geiger region" of operation. o The current pulses produced by the ionising events are passed to processing electronics which can derive a visual display of count rate or radiation dose, and usually in the case of hand-held instruments, an audio device producing clicks.
  • 21. Cheap, robust detector with a large variety of sizes and applications Large output signal from tube requiring minimal electronic processing for simple counting Can measure overall gamma dose when using energy compensated tube Advantages
  • 22. Cannot measure energy of radiation - no spectrographic information Will not measure high radiation rates due to dead time Sustained high radiation levels will degrade fill gas Disadvantages
  • 23. Radioactive isotopes interact with matter in two ways, ionisation & excitation.the latter effects leads an excited atom or compound (fluor) to emit photons of light.This process is known as Scintillation. When the light is detected by a photomultiplier converts the energy of radiation into an electrical signal, & the strenght of the electric pulse that results is directly proportional to the energy of the original radioactive event. Method based upon Excitation
  • 25. A scintillation counter is an instrument for detecting and measuring ionizing radiation. It consists of a scintillator which generates photons of light in response to incident radiation, a sensitive photomultiplier tube which converts the light to an electrical signal, and the necessary electronics to process the photomultiplier tube output.
  • 27. When a charged particle strikes the scintillator, its atoms are excited and photons are emitted. These are directed at the photomultiplier tube's photocathode, which emits electrons by the photoelectric effect. These electrons are electrostatically accelerated and focused by an electrical potential . The scintillator must be in complete darkness so that visible light photons do not swamp the individual photon events caused by incident ionising radiation.
  • 28. Schematic of a scintillating crystal combined with a photomultiplier.
  • 29. Fluroscence is very fast so there is no dead time. Counting efficiences are high . Ability to count samples of many types like liquid, solids & gels. Highly automated. Advantages
  • 30. Cost of the instrument & cost per sample. Potentially high background noise. Quenching Chemiluminescence phospholuminescence disadvatages
  • 31. Scintillation counters are used to measure radiation in a variety of applications. o Hand held radiation survey meters o Personnel and environmental monitoring for Radioactive contamination. o Medical imaging. o National and homeland security. o Border security. o Nuclear plant safety. o Oil well lodging. Applications
  • 32. AUTORADIOGRAPHY Radiography is the visualisation of the pattern of distribution of radiation. In general, the radiation consists of X-rays, gamma (g ) or beta (b ) rays, and the recording medium is a photographic film. In contrast, in autoradiography the specimen itself is the source of the radiation, which originates from radioactive material incorporated into it.
  • 33. • Living cells are briefly exposed to a ‘pulse’ of a specific radioactive compound. • Samples are taken, fixed, and processed for light or electron microscopy. • Left in the dark for days or weeks (while the radioisotope decays). • The photographic emulsion is developed (as for conventional photography). • Counterstaining . • Alternatively, pre-staining of the entire block of tissue can be done. • It is not necessary to coverslip these slides • The position of the silver grains in the sample is observed by light or electron microscopy . • These autoradiographs provide a permanent record. • Full details on the batch of emulsion used, dates, exposure time and conditions should be kept for each experiment. Autoradiography Method
  • 34. Radioisotopes by D. Billington,G. Jayson Principles & techniques in practical biochemistry by KeithWilson, John walker Principles & techniques of Biochemistry & molecular biology by R.J.Slater www.ansto.gov.au/NuclearFacts/.../Radioisotopes/index.htm www.kentchemistry.com/links/Nuclear/radioisotopes.htm www.lab.anhb.uwa.edu.au/hb313/main_pages/.../autoradiography.htm www.wikipedia.org/wiki/Liquid_scintillation_counting References