This document provides specifications for precast concrete manholes used for waste water. It lists the materials used to construct the manhole, including the bottom slab, blinding, channel/gutter, landing, concrete shaft rings, taper shaft ring, support ring and leveling course. It specifies the class and standards for the concrete, reinforcement and cement mortar. All joints must be sealed with rubber seals or waterproof cement mortar. Support rings of up to 28cm in height can be used under the manhole cover, along with a leveling course of up to 5cm thick concrete.