The document presents a comparative study on the structural behavior of reinforced concrete (RCC) and steel twisted buildings under dynamic loads. Models of 50-story and 25-story RCC and steel twisted buildings with twist rates of 1.5, 2.5, and 3.5 degrees per floor were analyzed using SAP2000. Parameters like displacement, story drift, time period, and base shear were compared between RCC and steel structures. The analysis found that steel twisted buildings performed better with less displacement and story drift compared to RCC under seismic and wind loads. A twist rate of 3.5 degrees per floor was also found to be more efficient than lower rates.
Design & Analysis of High rise Building With & Without Floating Column Using ...IJSRD
At present buildings with floating column is a typical feature in the modern multistory construction in urban India. There are many projects in which floating columns are adopted, especially above the ground floor, where transfer girders are employed, so that more open space is available in the ground floor. As the load path in the floating columns is not continuous, they are more vulnerable to the seismic activity. Sometimes, to meet the requirements these type of aspects cannot be avoided though these are not found to be of safe. Hence, an attempt is taken to study the behavior of a G+15 multi storey building in which some storey’s are considered for commercial purpose and remaining storey’s are for residential purpose. This paper studies the comparison & seismic analysis of the multistory buildings with floating column and without floating column. Finally, analysis & results in the high rise building such as storey drifts, storey displacement, and Base shear were shown in this study. Design and Analysis was carried out by using Extended Three Dimensional Analysis of Building Systems (ETABS) Software.
CADmantra Technologies Pvt. Ltd. is one of the best Cad training company in northern zone in India . which are provided many types of courses in cad field i.e AUTOCAD,SOLIDWORK,CATIA,CRE-O,Uniraphics-NX, CNC, REVIT, STAAD.Pro. And many courses
Contact: www.cadmantra.com
www.cadmantra.blogspot.com
www.cadmantra.wix.com
Analysis and design of high rise building frame using staad proeSAT Journals
Abstract The Aim of present study “Analysis and design of high rise building by staad pro 2008” is to define proper technique for creating Geometry, cross sections for column and beam etc, developing specification and supports conditions, types of Loads and load combinations. In this study a 30- storey high rise structure is analyzed for seismic and wind load combination using staad pro 2008 and comparison is drawn. Keywords: Analysis, Geometry, Structure, Wind load
Design & Analysis of High rise Building With & Without Floating Column Using ...IJSRD
At present buildings with floating column is a typical feature in the modern multistory construction in urban India. There are many projects in which floating columns are adopted, especially above the ground floor, where transfer girders are employed, so that more open space is available in the ground floor. As the load path in the floating columns is not continuous, they are more vulnerable to the seismic activity. Sometimes, to meet the requirements these type of aspects cannot be avoided though these are not found to be of safe. Hence, an attempt is taken to study the behavior of a G+15 multi storey building in which some storey’s are considered for commercial purpose and remaining storey’s are for residential purpose. This paper studies the comparison & seismic analysis of the multistory buildings with floating column and without floating column. Finally, analysis & results in the high rise building such as storey drifts, storey displacement, and Base shear were shown in this study. Design and Analysis was carried out by using Extended Three Dimensional Analysis of Building Systems (ETABS) Software.
CADmantra Technologies Pvt. Ltd. is one of the best Cad training company in northern zone in India . which are provided many types of courses in cad field i.e AUTOCAD,SOLIDWORK,CATIA,CRE-O,Uniraphics-NX, CNC, REVIT, STAAD.Pro. And many courses
Contact: www.cadmantra.com
www.cadmantra.blogspot.com
www.cadmantra.wix.com
Analysis and design of high rise building frame using staad proeSAT Journals
Abstract The Aim of present study “Analysis and design of high rise building by staad pro 2008” is to define proper technique for creating Geometry, cross sections for column and beam etc, developing specification and supports conditions, types of Loads and load combinations. In this study a 30- storey high rise structure is analyzed for seismic and wind load combination using staad pro 2008 and comparison is drawn. Keywords: Analysis, Geometry, Structure, Wind load
Richa Industries Limited customizes structural steel system for heavy construction and offers design,engineering and construction solution from concept to completion.
EFFECT OF SEISMIC LOAD ON RCC STRUCTUREAbhinav Verma
I am Abhinav Verma Student of B.Tech. [Civil Engineering] form ASHOKA INSTITUTE OF TECHNOLOGY AND MANAGEMENT , VARANASI Affiliated to Dr.A.P.J. ABDUL KALAM TECHNICAL UNIVERSITY , LUCKNOW , UTTAR PRADESH, INDIA.
In this Project Work my role as Groupleader with our Project Member Kuwar Limay Siddhartha ,Avinash Singh Suraj Kumar Arya.and our Guide Er.Rahul Singh ,Associate Professor , Our Head of Department Er.Dharmendra Dubey with all the Faculties Department of Civil Engineering.
Select the Model for Case Study Collected data and analyzed model in STAAD Pro and study about its behavior against seismic load and also concern the preventive measures taken to overcome the effect of seismic loading on RCC Structure.
EFFECT OF SEISMIC LOAD ON REINFORCED CONCRETE MULTISTORY BUILDING FROM ECONOM...IAEME Publication
This paper aims at studying the effect of earthquake loading on the constructional
design of a 20-storey reinforced concrete residential building from economical point
of view. This type of loading should be taken into considerations now in Iraq
especially after the earthquake of 7.3 magnitude that occurred in November 2017 near
the city of Halabja by about 31 kilometers. The same reinforced concrete multistory
building was designed twice; once with traditional gravity dead and live loading and
the second with adding earthquake loading in order to discuss the difference from
structural and economical points of view. A commercial package ETABS2018 was
used to analyze this 60-meter-high building. The building was analyzed according to
the American code ASCE7-10, while it was designed according to ACI 318-14. A huge
increase in the steel reinforcement amounts in columns, beams, slabs and shear walls
were recorded due to taking the seismic load into considerations. More specifically,
the reinforcing steel amounts increased by about 327%, 165%, 40% and 91.3% for
columns, beams, slabs and shear walls, respectively. Therefore, cost was raised by
about 328%, 165%, 40% and 91.3% for columns, beams, slabs and shear walls,
respectively. It is worth to mention here that the maximum increase in main
reinforcement of beams was observed on the storey 10. Whereas, in slabs, the
maximum increase that was recorded in main steel reinforcement was happened from
the storey 8 to the building top. In columns, the main reinforcement increase was seen
on the 9th, 10th and 11th storeys. Finally, in shear walls, the main reinforcement
increase was seen in the 1
st
, 2
nd
and 3
rd
storey due to effect lateral shear forces
analysis and design of mutistoried residential building by using staad pro
we considered g+4 residential building
ANYLYSIS AND DESIGN OF HIGH RISE RESIDENTIAL BUILDING BY USING ETABS
copy below Link to view presentation
https://www.slideshare.net/ilavamsikrishna/analysis-and-design-of-high-rise-building-by-using-etabs
vamsiila@gmail.com
Comparative Evaluation Of Reinforced Concrete, Steel And Composite Structures...IJERA Editor
Steel-concrete composite construction has gained wide acceptance all over the world as an alternative for pure steel and pure concrete construction. However this approach is a new concept for construction industry. R.C.C are no longer economical because of their increased dead load, hazardous formwork. The present study deals with comparison of reinforced concrete, steel and composite structures under the effect of static and dynamic loads. The results of this work show that composite structures are best suited for high rise buildings compared to that of steel and reinforced concrete structures. Response spectrum method is used for comparison of three structures with the help of ETABS software.
Richa Industries Limited customizes structural steel system for heavy construction and offers design,engineering and construction solution from concept to completion.
EFFECT OF SEISMIC LOAD ON RCC STRUCTUREAbhinav Verma
I am Abhinav Verma Student of B.Tech. [Civil Engineering] form ASHOKA INSTITUTE OF TECHNOLOGY AND MANAGEMENT , VARANASI Affiliated to Dr.A.P.J. ABDUL KALAM TECHNICAL UNIVERSITY , LUCKNOW , UTTAR PRADESH, INDIA.
In this Project Work my role as Groupleader with our Project Member Kuwar Limay Siddhartha ,Avinash Singh Suraj Kumar Arya.and our Guide Er.Rahul Singh ,Associate Professor , Our Head of Department Er.Dharmendra Dubey with all the Faculties Department of Civil Engineering.
Select the Model for Case Study Collected data and analyzed model in STAAD Pro and study about its behavior against seismic load and also concern the preventive measures taken to overcome the effect of seismic loading on RCC Structure.
EFFECT OF SEISMIC LOAD ON REINFORCED CONCRETE MULTISTORY BUILDING FROM ECONOM...IAEME Publication
This paper aims at studying the effect of earthquake loading on the constructional
design of a 20-storey reinforced concrete residential building from economical point
of view. This type of loading should be taken into considerations now in Iraq
especially after the earthquake of 7.3 magnitude that occurred in November 2017 near
the city of Halabja by about 31 kilometers. The same reinforced concrete multistory
building was designed twice; once with traditional gravity dead and live loading and
the second with adding earthquake loading in order to discuss the difference from
structural and economical points of view. A commercial package ETABS2018 was
used to analyze this 60-meter-high building. The building was analyzed according to
the American code ASCE7-10, while it was designed according to ACI 318-14. A huge
increase in the steel reinforcement amounts in columns, beams, slabs and shear walls
were recorded due to taking the seismic load into considerations. More specifically,
the reinforcing steel amounts increased by about 327%, 165%, 40% and 91.3% for
columns, beams, slabs and shear walls, respectively. Therefore, cost was raised by
about 328%, 165%, 40% and 91.3% for columns, beams, slabs and shear walls,
respectively. It is worth to mention here that the maximum increase in main
reinforcement of beams was observed on the storey 10. Whereas, in slabs, the
maximum increase that was recorded in main steel reinforcement was happened from
the storey 8 to the building top. In columns, the main reinforcement increase was seen
on the 9th, 10th and 11th storeys. Finally, in shear walls, the main reinforcement
increase was seen in the 1
st
, 2
nd
and 3
rd
storey due to effect lateral shear forces
analysis and design of mutistoried residential building by using staad pro
we considered g+4 residential building
ANYLYSIS AND DESIGN OF HIGH RISE RESIDENTIAL BUILDING BY USING ETABS
copy below Link to view presentation
https://www.slideshare.net/ilavamsikrishna/analysis-and-design-of-high-rise-building-by-using-etabs
vamsiila@gmail.com
Comparative Evaluation Of Reinforced Concrete, Steel And Composite Structures...IJERA Editor
Steel-concrete composite construction has gained wide acceptance all over the world as an alternative for pure steel and pure concrete construction. However this approach is a new concept for construction industry. R.C.C are no longer economical because of their increased dead load, hazardous formwork. The present study deals with comparison of reinforced concrete, steel and composite structures under the effect of static and dynamic loads. The results of this work show that composite structures are best suited for high rise buildings compared to that of steel and reinforced concrete structures. Response spectrum method is used for comparison of three structures with the help of ETABS software.
CW RADAR, FMCW RADAR, FMCW ALTIMETER, AND THEIR PARAMETERSveerababupersonal22
It consists of cw radar and fmcw radar ,range measurement,if amplifier and fmcw altimeterThe CW radar operates using continuous wave transmission, while the FMCW radar employs frequency-modulated continuous wave technology. Range measurement is a crucial aspect of radar systems, providing information about the distance to a target. The IF amplifier plays a key role in signal processing, amplifying intermediate frequency signals for further analysis. The FMCW altimeter utilizes frequency-modulated continuous wave technology to accurately measure altitude above a reference point.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.