This document summarizes a study that analyzed the progressive collapse of a 14-story steel frame structure due to fire loads using ETABS software. The structure was modeled and analyzed by applying a fire load of 550°C to corner, edge, intermediate, and re-entrant columns on alternating floors according to GSA guidelines. Demand capacity ratios and axial loads of the columns were obtained both before and after the fire load was applied. The results showed demand capacity ratios remained below 2 and axial loads increased after fire, indicating the structure would not experience progressive collapse from the simulated fire loads.
Design and comparison of a residential building (g+10) for seismic forces usi...eSAT Journals
Abstract Earthquakes take a huge toll on life and property. Since the effect of seismic forces on structures is quite significant, it is important that the design of the structures must be done in the best possible way to take into account these effects and thereby aiming for an adequate structural response. Different international seismic codes differ significantly in parameters specified. With the variations in parameters the performance of the building varies. Hence, it is necessary to do a comparative study so as to conclude which building will perform better. This paper presents with the analysis and design of a G+10 for seismic forces using four international building standards- IS1893, Euro code 8, ASCE7-10 and the British Codes. The analysis of the building was done using STAAD.Pro.V8i. The building was then designed as per the specified codes. Once the design was completed a pushover analysis was done in SAP2000 to check the seismic performance of the building. A comparative study between the design and the seismic performance of the building was done. Keywords: Seismic forces, Seismic Standard, Seismic performance, Comparative Analysis.
Design and comparison of a residential building (g+10) for seismic forces usi...eSAT Journals
Abstract Earthquakes take a huge toll on life and property. Since the effect of seismic forces on structures is quite significant, it is important that the design of the structures must be done in the best possible way to take into account these effects and thereby aiming for an adequate structural response. Different international seismic codes differ significantly in parameters specified. With the variations in parameters the performance of the building varies. Hence, it is necessary to do a comparative study so as to conclude which building will perform better. This paper presents with the analysis and design of a G+10 for seismic forces using four international building standards- IS1893, Euro code 8, ASCE7-10 and the British Codes. The analysis of the building was done using STAAD.Pro.V8i. The building was then designed as per the specified codes. Once the design was completed a pushover analysis was done in SAP2000 to check the seismic performance of the building. A comparative study between the design and the seismic performance of the building was done. Keywords: Seismic forces, Seismic Standard, Seismic performance, Comparative Analysis.
Design of multi storey building resting on single columneSAT Journals
Abstract The aim of the project is to analyze and design of multi-storey building resting on the single column by using different code
provisions. A lay out plan of the proposed building is drawn by using AUTO CADD 2010.The structure consist of ground floor
plus five floors, each floor having the one house .Staircase must be provides separately. The planning is done as per Indian
standard code provisions. The building frames are analyzed using the various text books. Using this so many standard books
analysis of bending moment, shear force, deflection, end moments and foundation reactions are calculated. Detailed structural
drawings for critical and typical R.C.C. members are also drawn. Co-ordinates for all structural members are tabulated for ready
reference.
Keywords: Multi Story Building, Single Column, Staircase.
Analysis and design of high rise building frame using staad proeSAT Journals
Abstract The Aim of present study “Analysis and design of high rise building by staad pro 2008” is to define proper technique for creating Geometry, cross sections for column and beam etc, developing specification and supports conditions, types of Loads and load combinations. In this study a 30- storey high rise structure is analyzed for seismic and wind load combination using staad pro 2008 and comparison is drawn. Keywords: Analysis, Geometry, Structure, Wind load
Seismic Analysis and Design of Reinforced Concrete Multistory Building under ...ijtsrd
Impact of wind load as a marvel on structures, especially tall plans cant be unseen. Its major to ponder the deferred result of wind in style and appraisal of plans. The plan is explored for the gravity loads and besides for the equivalent loads for example wind load in zone ii Bhopal , zone iii Nagpur , zone iv Delhi , zone v Calcutta , zone vi Darbhanga .The structure is made on the thing known as staad.pro v8i. This appraisal is the assessment of the Reinforced strong cement multi story building G 10 . The codes utilized for the evaluations of Dead weight are IS 875 Part 1 1987 ,for live weight the code IS 875 Part 2 1987 and for the incorporates of wind power in various breeze zones are IS 875 fragment 3 1987.The deferred result of these appraisal shows the adjustment of forces, departures responses and weight of steel the proportion of partner material expected to negate equivalent loads will increase without a doubt. Amount of essential material expected to go against sidelong loads will augment profoundly. Subodh Kumar | Prof. Priyanka Dubey "Seismic Analysis & Design of Reinforced Concrete Multistory Building under Different Zone's" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-6 , October 2021, URL: https://www.ijtsrd.com/papers/ijtsrd46404.pdf Paper URL : https://www.ijtsrd.com/engineering/civil-engineering/46404/seismic-analysis-and-design-of-reinforced-concrete-multistory-building-under-different-zone's/subodh-kumar
CADmantra Technologies Pvt. Ltd. is one of the best Cad training company in northern zone in India . which are provided many types of courses in cad field i.e AUTOCAD,SOLIDWORK,CATIA,CRE-O,Uniraphics-NX, CNC, REVIT, STAAD.Pro. And many courses
Contact: www.cadmantra.com
www.cadmantra.blogspot.com
www.cadmantra.wix.com
Design of G+8 RCC Training Institute & Hostel Blockjeyanthi4
The building is located in seismic zone V and the basic wind speed in this location is 55m/s. The preliminary gravity and lateral load analysis are carried out manually for a typical 2D frame and compared with software results. The member sizes for beams and columns were found out from the preliminary manual analysis and design. 3D finite element modeling was carried out in ETABS for the building. Based on the analytical results (moment, shear force), the member sizes are finalized and design was carried out as per the codes IS 456, SP16, IS 13920. Ductile design and detailing is carried out as per IS 13920 & SP34.
Design of multi storey building resting on single columneSAT Journals
Abstract The aim of the project is to analyze and design of multi-storey building resting on the single column by using different code
provisions. A lay out plan of the proposed building is drawn by using AUTO CADD 2010.The structure consist of ground floor
plus five floors, each floor having the one house .Staircase must be provides separately. The planning is done as per Indian
standard code provisions. The building frames are analyzed using the various text books. Using this so many standard books
analysis of bending moment, shear force, deflection, end moments and foundation reactions are calculated. Detailed structural
drawings for critical and typical R.C.C. members are also drawn. Co-ordinates for all structural members are tabulated for ready
reference.
Keywords: Multi Story Building, Single Column, Staircase.
Analysis and design of high rise building frame using staad proeSAT Journals
Abstract The Aim of present study “Analysis and design of high rise building by staad pro 2008” is to define proper technique for creating Geometry, cross sections for column and beam etc, developing specification and supports conditions, types of Loads and load combinations. In this study a 30- storey high rise structure is analyzed for seismic and wind load combination using staad pro 2008 and comparison is drawn. Keywords: Analysis, Geometry, Structure, Wind load
Seismic Analysis and Design of Reinforced Concrete Multistory Building under ...ijtsrd
Impact of wind load as a marvel on structures, especially tall plans cant be unseen. Its major to ponder the deferred result of wind in style and appraisal of plans. The plan is explored for the gravity loads and besides for the equivalent loads for example wind load in zone ii Bhopal , zone iii Nagpur , zone iv Delhi , zone v Calcutta , zone vi Darbhanga .The structure is made on the thing known as staad.pro v8i. This appraisal is the assessment of the Reinforced strong cement multi story building G 10 . The codes utilized for the evaluations of Dead weight are IS 875 Part 1 1987 ,for live weight the code IS 875 Part 2 1987 and for the incorporates of wind power in various breeze zones are IS 875 fragment 3 1987.The deferred result of these appraisal shows the adjustment of forces, departures responses and weight of steel the proportion of partner material expected to negate equivalent loads will increase without a doubt. Amount of essential material expected to go against sidelong loads will augment profoundly. Subodh Kumar | Prof. Priyanka Dubey "Seismic Analysis & Design of Reinforced Concrete Multistory Building under Different Zone's" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-5 | Issue-6 , October 2021, URL: https://www.ijtsrd.com/papers/ijtsrd46404.pdf Paper URL : https://www.ijtsrd.com/engineering/civil-engineering/46404/seismic-analysis-and-design-of-reinforced-concrete-multistory-building-under-different-zone's/subodh-kumar
CADmantra Technologies Pvt. Ltd. is one of the best Cad training company in northern zone in India . which are provided many types of courses in cad field i.e AUTOCAD,SOLIDWORK,CATIA,CRE-O,Uniraphics-NX, CNC, REVIT, STAAD.Pro. And many courses
Contact: www.cadmantra.com
www.cadmantra.blogspot.com
www.cadmantra.wix.com
Design of G+8 RCC Training Institute & Hostel Blockjeyanthi4
The building is located in seismic zone V and the basic wind speed in this location is 55m/s. The preliminary gravity and lateral load analysis are carried out manually for a typical 2D frame and compared with software results. The member sizes for beams and columns were found out from the preliminary manual analysis and design. 3D finite element modeling was carried out in ETABS for the building. Based on the analytical results (moment, shear force), the member sizes are finalized and design was carried out as per the codes IS 456, SP16, IS 13920. Ductile design and detailing is carried out as per IS 13920 & SP34.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.