Fuel Consumption measurement System(FCS) is a self-contained SKID housing Fuel Tank, Tank Weighing System (TWS) of Mettler Toledo (Model No. IND 570), Fuel Tank Filling Pumps/Flame Proof Motor, Temperature Sensors (RTD), Shell & Tube Type Heat Exchangers for cooling of Fuel and a Control Panel (CP) for user to interact with the system. All electronic/software controls & communication interaction with the FCS SKID is through this CP.
Instruct Nirmaana 24-Smart and Lean Construction Through Technology.pdf
fuel-consumption-measurement-system.pptx
1.
2.
3. This PC based Data Acquisition & Control Software is meant for conducting collapse test of
Test Filter. It provides the facility to monitor the input/ output parameters such as
Differential Pressure, Flow Rate etc. The solution involves a Data Acquisition, Feedback &
Control system that interfaces with Pressure, Temperature, Flow Sensors, Solenoid Valves,
Level Sensors & the AC drive.
4.
5. Filter Clogging Indicator Switch (6.0) which indicates that the Filter is clogged
Tank Weighing System comprising of 4 Load Cells, Flameproof Junction Box & IND 570
Indicator
Temperature Sensors installed to monitor the temperature of chilled water as well as the
fuel.
Ball Valve at the suction of the Fuel Tank Filling Pump is MANUAL and has a limit switch
which tells that this Valve is Open
Float Switches get activated in case of Fuel Tank overfill or Fuel Tank over flow
PLC Controller is connected with Temperature Sensors, Limit Switches on Valves and
Filter Clogging Indicator Switches on filters and also Float Switched.
PLC Controller is also connected with Chiller through RS485
The HMI on control panel will always show the current status (Open/Close, On/Off) of all
components in the Fuel Circuit.
6.
7. • Flame Proof ELECTRIC MOTOR : 1.5KW, 1440 RPM,Three PHASE, 4 POLE, 50HZ
• Fuel Filter: Filtration :10 Micron(absolute), with electronic Clogging Indicator.
• Fuel tank(material ss-304): 150 ltr fuel tank
• Temperature sensor (rtd): range: 0 to 100 degree c
• Shell & Tube Type Heat Exchanger: Fuel Line Pressure Drop 0.01 Bar.
• Refregirated water chiller : Three phase refrigerated air cooled chiller
• Ms Sheet Metal Box For Control Panel: 600h X 600w X 350d (Sheet Metal Enclosure With
600x600x350 Mm
• Power Supply: 220/4.2a,24v,Dc
• Panel Light: Panel Light
8.
9. Application
This PC based Data Acquisition & Control Software is meant for testing of Life and
Efficiency of the Test Filter. It provides the facility to monitor the input/ output parameters
such as Differential Pressure, Flow Rate, Temperature etc. The solution involves a Data
Acquisition, Feedback & Control system that interfaces with Pressure, Temperature, Flow
Sensors, On/Off Valves, Level Sensors, AC drives.