SlideShare a Scribd company logo
1 of 72
POTENTIOMETRY
Presented by
G.Pavani
Y17MPHPA426
Chalapathi institute of pharmaceutical sciences,Lam,Guntur(Dt).
pH is a Potentiometric Measurement
The Measuring System consists of a pH Measuring
Electrode (indicating electrode) and Reference Electrode
The Potential Difference Between the Two Electrodes is a
Function of the pH Value of the Measured Solution.
The Analyte Solution Must Be Conductive and is Part of
the Electrical Circuit.
POTENTIOMETRIC ANALYSIS
 Based on potential measurement of
electrochemical cells without any appreciable
current
 The use of electrodes to measure voltages from
chemical reactions
DEFINITION
Potentiometry:
“Measuring the potential or Emf of a solution by
using the set of Indicator electrode and reference electrode”.
The potential(E)of a metal elctrode at25 C,immersed into a
solution of its own ions is given by
E=E0 + 0.0592 × logc
n
Where, E0 = standard potential of the electrode
n = valency of ions
c = concentration of ions
Nernest equation
COMPONENTS OF A
POTENTIOMETRIC CELL
1. Reference electrode
2. Salt bridge
3. Analyte
4. Indicator electrode
RE SB A IE
– Eref + Ej + Eind
REFERENCE ELECTRODE
• Half-cell with known potential (Eref)
• Left hand electrode (by convention)
• Easily assembled
• Rugged
• Insensitive to analyte concentration
▫ Reversible and obeys Nernst equation
▫ Constant potential
▫ Returns to original potential
INDICATOR ELECTRODE
 Generates a potential (Eind) that depends on
analyte concentration
 Selective
 Rapid and reproducible response
SALT BRIDGE
 Prevents mixing up of analyte components
 Generates potential (Ej) = negligible
REFERENCE ELECTRODES
1. Standard Hydrogen Electrode
2. Saturated Calomel Reference Electrode
3. Silver/Silver Chloride -Reference Electrode
HYDROGEN ELECTRODE
o It can be used as Indicator as well
as Reference eletrode.
o It can be consist of platinum foil
coated with platinum balck and has
a wire contacts through a mercury.
o This assembly is enclosed in a glass
covering.
o Hydrogen gas is passed at
1atmospheric pressure
continuously.
o (Pt (H2 (1 atm), H+ (1M)
o Then eletrode is dipped into the standard acid /unknown
solution.
o All the times surface of the electrode and the solution
should be saturated with the gas.
o potential ,
o E=E0H+0.0592log[H+]
=E0H-0.0592pH(pH=-log [H+]
 E=-0.0592 pH.
 E0=std Eof H2 electrode ,taken as 0
Advantages and Disadvantages of H2Electrode:
 Advantages:
 It can be used over the entire pH.
 Itcan be used as a reference electrode when dipped with
standard acid solution and as a indicator electrode when
dipped into a sample solution.
 It is the primary reference standard against which the
potentials of other electrodes are measured.
 Disadvantages
 It is effected by the presence of oxidizing agent and reducing
agent.
 It is rather difficult to regulate the pressure of H2 gas to be
exactly 1 atm throughout the experiment.
 Platinum foil gets easily poisoned by the impurities present in
the H2 gas and Hcl solution.
Saturated calomel elctrode
• It consist of inner jacket and outer
sleeve
• Inner tube has a wire contact with
mercury(Hg) and plugged with a
mixture of calomel(Hg2cl2)and KCL.
• This is surrounded by an outer sleeve
• Tip is filled with Crystals of KCL and
porous plug of asbestos.
• The space between inner jacket and
outer sleeve is filled with saturated
KCL/1N KCL/0.1 N KCL.
• Potential of the electrode depends on
• The Concentration of the KCL
Solution. And Temperature.
• Merits:
Easy of construction
Stability of Potential.
• Demerits:
Dependent on temp
Toxic
• Applications:
Used in pH Measurement
Equation: Hg2Cl2(s)+2e-2Hg(l)+2Cl-(aq)
• 0.2444 V at 25C
Silver –Silver Chloride electrode
It is also widely used reference
electrode,
Because,It is simple
In expensive
Very stable
Non –toxic.
It is mainly used with Saturated KCL
Electrode (kcl electrolyte) but canbe
used with low concentration such as
1MKCL and even directly in sea water.
“Ag-wire coated
electrolytically with AgCl2 and dipped
into KCL
Potential depends on the concentration of the KCL and
temperature.
AgAgCl (satd),KCl (satd)
AgCl(s) + e-Ag(s)+Cl-(aq)
E = 0.199 V
Advantage:
Easy to use
 Dis advantage:
Difficult to prepare.
LIQUID JUNCTION POTENTIAL
 Liquid junction - interface between two solutions containing
different electrolytes or different concentrations of the same
electrolyte
 A junction potential occurs at every liquid junction.
 Caused by unequal mobilities of the + and - ions.
INDICATOR ELECTRODES
I. Metallic IE
A. Electrodes of the First Kind
B. Electrodes of the Second Kind
C. Inert Metallic Electrodes (for Redox Systems)
II. Membrane IE/Ion –Selective Electrodes.
A. Glass pH IE
B. Glass IE for other cations
C. Liquid Membrane IE
D. Crystalline-Membrane IE
III.Gas Sensing Probes/Gas Sensing Electrode.
METALLIC INDICATOR
ELECTRODES
ELECTRODES OF THE FIRST KIND
 Pure metal electrode in direct equilibrium with its cation
 Metal is in contact with a solution containing its cation.
M+n(aq) + ne-  M(s)
DISADVANTAGES OF FIRST KIND ELECTRODES
 Not very selective
 Ag+ interferes with Cu+2
 May be pH dependent
 Zn and Cd dissolve in acidic solutions
 Easily oxidized (deaeration required)
 Non-reproducible response
ELECTRODES OF THE SECOND KIND
 Respond to anions by forming precipitates or stable complex
 Examples:
1. Ag electrode for Cl- determination
2. Hg electrode for EDTA determination
INERT METALLIC (REDOX) ELECTRODES
 Inert conductors that respond to redox systems
 Electron source or sink
 An inert metal in contact with a solution containing the soluble
oxidized and reduced forms of the redox half-reaction.
 May not be reversible
 Examples:
 Pt, Au, Pd, C
ION SELECTIVE ELECTRODES
 Other synonym:Membrane electrodes
 Definition:
“ ISE are known as specific ion electrode, it is a membrane
that Converts the activity of a specific ion dissolved in a
solution into an electrode
Potential”.
 The voltage is theoritically dependent on the negative
logerithem of the ionic activity, according to the Nernest
equation.
Uses:
ISE are used in analytical chrmistry,bio-chemical/
biophysical research.
whwre, measurements of ionic concentration in
aqueous solutions are required.
TYPES OF ISE:
1.Glass Membrane electrode
2.Liquid-Liquid electrode/Liquid membrane
electrode.
3.Crystal Membrane electrode.
4.Gas sensing electrode.
1.GLASS PH ELECTRODE
Combined PH glass electrodepH measurement system
Working principle of pH glass membrane electrode
Principle of pH meter
STYLE OF GLASS ELECTRODE
• The glass membrane itself
is not limited to any
configuration or shape; its
only requirement is contact
with solution.
• Therefore, different styles
of glass electrodes have
evolved to maximize pH
sensing ability and extend
longevity in some of the
more difficult applications.
PROPERTIES OF GLASS PH ELECTRODE
 Potential not affected by the presence of oxidizing or reducing
agents
 Operates over a wide pH range
 Fast response
 Functions well in physiological systems
 Very selective
 Long lifespan
Theory of the glass membrane potential
 For the electrode to become operative, it must be soaked in water.
 During this process, the outer surface of the membrane becomes
hydrated.
 When it is so, the sodium ions are exchanged for protons in the
solution:
 The protons are free to move and exchange with other ions.
Charge is slowly carried
by migration of Na+
across glass membrane
Potential is determined
by external [H+]
ALKALINE ERROR
 Exhibited at pH > 9
 Electrodes respond to H+ and
alkali cations
 C,D,E and F: measured
value is < true value
 Electrode also responds to
other cations
 Higher pH at lower [Na+]
ACID ERROR
 Exhibited at pH < 0.5
 pH readings are higher
(curves A and B)
 Saturation effect with
respect to H+
2.LIQUID MEMBRANE ELECTRODES
• Potential develops across the interface between the analyte
solution and a liquid ion exchanger (that bonds with analyte)
• Similar to a pH electrode except that the membrane is an organic
polymer saturated with a liquid ion exchanger
• Used for polyvalent ions as well as some anions
• Example:
• Calcium dialkyl phosphate insoluble in water, but binds Ca2+
strongly
Responsive to Ca2+
0.1 M CaCl2
CHARACTERISTICS OF CA+2 ISE
 Relatively high sensitivity
 Low LOD
 Working pH range: 5.5 – 11
 Relevant in studying physiological processes
A K+-SELECTIVE ELECTRODE
 Sensitive membrane consists of
valinomycin, an antibiotic
3.CRYSTALLINE-MEMBRANE ELECTRODES
 Solid state electrodes
 Usually ionic compound
 Crushed powder, melted and formed
 Sometimes doped to increase conductivity
 Operation similar to glass membrane
CRYSTALLINE-MEMBRANE ELECTRODES:
 AgX membrane: Determination of X-
 Ag2S membrane: Determination of S-2
 LaF3 membrane: Determination of F-
EX:F- SELECTIVE ELECTRODE
 A LaF3 is doped with EuF2.
 Eu2+ has less charge than the La3+, so an anion vacancy occurs
for every Eu2+.
 A neighboring F- can jump into the vacancy, thereby moving the
vacancy to another site.
 Repetition of this process moves F- through the lattice.
FIG:FLUORIDE ELECTRODE
4.GAS SENSING ELECTRODE
 A galvanic cell whose potential is related to the concentration of a
gas in solution
 Consist of RE, ISE and electrolyte solution
 A thin gas-permeable membrane (PTFE) serves as a barrier
between internal and analyte solutions
 Allows small gas molecules to pass and dissolve into internal
solution
 O2, NH3/NH4
+, and CO2/HCO3
-/CO3
2-
FIG: GAS SENSING ELECTRODE
DIRECT POTENTIOMETRY
• A rapid and convenient method of determining the activity of
cations/anions
POTENTIOMETRIC MEASUREMENT
1. Calibration Method
2. Standard Addition Method
POTENTIOMETRIC TITRATION
 Involves measurement of the potential of a suitable indicator
electrode as a function of titrant volume
 Provides MORE RELIABLE data than the usual titration
method
 Useful with colored/turbid solutions
 May be automated
 More time consuming
POTENTIOMETRIC TITRATION CURVES
POTENTIOMETRIC TITRATIONS
 Is a technique similar to direct titration of a redox
reaction.
 No indicator is used, (instead the potential across the
analyte) typically an electrolyte solution is measured.
 To do this, two electrodes are used, an indicator electrode
and a reference electrode.
 The indicator electrode forms an electrochemical half
cell with the interested ions in the test solution.
 The reference electrode forms the other half cell,
holding a consistent electrical potential.
WHEN POTENTIOMETRIC TITRATIONS IS
USED?
 It is used when the endpoints are very difficult to
determine either when:
1- very diluted solution.
2-coloured and turbid solution.
3-absence of a suitable indicator.
INSTRUMENTS
PH meter
Reference electrode.
Indicator electrode.
Voltmeter which measures the potential difference.
 Magnetic stirrer.
hot plate ( use the stirrer and make sure heat is off ).
magnet capsule .
•Glass (burrete and beaker)
of 0.1 N NaOH
Potentiometric titration curve of (0.1 N) NaOH against
(?? N ) acetic acid :
 Do not place the electrodes anywhere except attached to the
electrode holder.
 At the end of the experiment rinse the electrodes and place
each one in its housing as required.
 Never touch the glass part of the electrode with anything
except soft tissue paper. While in use, the bulb of the glass
electrode should be immersed in solution.
IMORTANT TO KNOW
o For short-term storage the combined glass electrode
should be immersed in solution of 2 M KCl.
o Buffer solutions of known pH are used for the pH
calibration.
o For high accuracy, calibration and measurements are to
be performed at the same temperature.
1-the outside surface of the glass membrane is in contact with
the sample being measured.
2-and the inside surface contact the inner filling solution .
3-A complex mechanism at each glass liquid interface defines the
potential of the pH glass electrode.
4-While the pH inner glass /filling solution potential is constant ,
the outside potential varies based on the hydrogen ion
concentration in the sample.
Applications of Potentiometry:
1. Direct potentiometry:
 A rapid and convinient method of detecting the
activity of cations and anions.
 The technique used in this method is a comparison of
the potential developed by the indicator electrode when
it is immersed in the solution with that when it is
immersed in standard solution of the analyte.
2. The calibration curve method:
 It is applied for determination of substance by direct
potentiometry.
 In which we plot potential of the cell Vs a series of
standard solution of extragrade of the substance to be
determined.
 Then measure the potential prodused when using the
unknown solution and from the calibration curve we can
obtain its concentrations.
3. Environmental chemistry:
 Pollution monitoring: CN,F,S,Li,Na, etc…..in effluents
and natural water
4. Agriculture :
NO3,Cl,I,K,Ca,CN, in Soil, plant material, Fertilizers,
Feedstuffs.
5 . Food processing:
No3,No2 in Meat, and preservatives.
6. Florin in drinking water and other drinkers.
7. Salt content of Meat,Fish,Dairy
products,Fruits,Juices,Brewing Solutions.
8. Potentiometric titrations:
 Acid-Basetitrations (aqueous and non aqueous)
 Redox titrations
 Diazotisation titrations
 Precipitation titrations
 Complexometric titrations
 Dead stop end point technique.
1.Acid –base titrations:
Titrations can be done in aqueous and non-aqueous
medium.
E+k-0.0592pH.
Ex:-Aqueous medium:any strength-0.01N,0.1N,1N.
o Acid-base combinations:
Weak acid - Weak base Weak acid-Strong base
(CH3COOH Vs NH4OH) (CH3COOH-NAOH)
Strong acid-Strong base Strong acid-Weak base
(HCL-NAOH) (HCL-NH4OH)
oMixture of acids Vs bases: (CH3COOH+HCL)Vs NAOH
oMixture of bases Vs acids: (NH4OH+NAOH) Vs HCL.
oPoly basis acids Vs bases: Citric acid Vs NAOH
Tartaric acid Vs NAOH.
• Non aqueous medium:
 Weak acidVs pottasium(KOME)/Lithium methoxide(Liome)
 Ex:-Barbituric acid Vs LiOMe
 Weak bases Vs perchloric acid
 Ex:-Ephedrine Hydrochloride
/Q.sulphate/Metronidazole/Chloroquine phosphate Vs
0.1NHCLO4.
 Indicator electrode:Glass electrode
 Reference electrode:SCE
2. Redox-titrations:
 Reaction:Ce4+ + Fe2+ Ce3+ + Fe3+
 Ce4+ is an oxydising agent which oxidises Fe2+
(ferrous) to Fe3+(ferric ion), in this process
Ce4+(cerric) gets redused to Ce3+ (cerrous ions).
 E =E0 + 0.0592/n.log(ox)/(Red).
 Where,E0= std potential.
 n= no.of electrons involved in the reaction,
 (ox)= conc. Of oxidant
 (Red)= conc of reductant.
 Reference electrode:SCE,Ag-Agcl2 electrode.
 Indicator electrode:platinum wire or foil.
mv scale is used for end point detection.
Ex:-Ferrous ammonium sulphate in dilute
H2SO4VsKMNO4/K2Cr2O7.
3.Diazotisation titrations:
 Drugs or substances containing aromatic amino group can
be titrated against sodium nitrate in acidic medium.
 Result in the formation of diazonium salt this type of titration
is called as Diazotisation titration.
 End point detecting:by
 a)Starch iodide paper(externalindicator method)
 Potentiometric method of detecting end point.
 Reference electrode:SCE
 Indicator electrode:Glass electrode.
 Ex:Alkaloids,Amines,Sulpha drugs which contain
primary aromatic amino group can be titrated
against0.1N sodium Nitrate in HCl .
4)Precipitation titrations:
 For quantitative determination of several ions or elements
precipitating agents are used as titrants,
 End point is determined by potentiometric method.
 E=E0+0.0592/n.log[Mn+]
where, [Mn+]=conc of ions
n= electronic state.
 Reference electrode:SCE,H2,Ag-AgCl2 electrode
 Indicator electrode:Silver wire electrode.
 Ex: Determination of Hg,Ag,Pb,Cu, and other
ions using precipitants to form insoluble salts.
5)Complexometric titrations:
 Metalic ions (divalent)can be titrated against disodium
edetate solutions by potentiometric method
 Measurements are made inmv scale.
• Reference electrode:SCE/ any other.
• Indicator electrode:Ag / Hg electrode.
• Ex:-Di and Trivalent ions.
(mix of Bi3+,Cd2+,Ca2+ by using EDTA).
Applications of Potentiometer
as (I.Pmethods )
S.NO DRUGS TITRANT INDICATOR
ELECTRODE
REFERENCE
ELECTRODE
1 Amoxicillin sodium Mercuric nitrate Pt/Hg Hg-mercurous
sulphate
2 Acebutalol HCl NaOH Glass SCE/Ag-AgCl
3 Dextromorphan HCl NaOH Glass SCE/Ag-AgCl
4 DiphenoxylateHCl Ethanolic NaOH Glass SCE/Ag-AgCl
5 Disulfiram Ag2NO3 Silver SCE
6 Hydralazine HCl Potassium iodate platinum SCE
7 Lomustine silvernitrate silver Calomel
8 Metoclopromide HCl NaOH Glass SCE
9 Naldixic acid Ethanolic sodium
of hydroxide
Glass Ag-AgCl
10 Phenobarbitone sodium NaOH Glass SCE
11 Promithazine HCl NaOH Glass SCE
12 propranalololHCl NaOH Glass SCE
13 Sodium stibogluconate injection Ferric ammonium
sulphate
pt Ag-AgCl
Potentiometry

More Related Content

What's hot

What's hot (20)

Potentiometry titration
Potentiometry titrationPotentiometry titration
Potentiometry titration
 
Polarography
PolarographyPolarography
Polarography
 
INDICATOR ELECTRODE
INDICATOR ELECTRODEINDICATOR ELECTRODE
INDICATOR ELECTRODE
 
Potentiometry
PotentiometryPotentiometry
Potentiometry
 
Non aqueous titrations
Non aqueous titrationsNon aqueous titrations
Non aqueous titrations
 
Polarography principle and instrumentation
Polarography principle and instrumentationPolarography principle and instrumentation
Polarography principle and instrumentation
 
Polarometery
PolarometeryPolarometery
Polarometery
 
AMPEROMETRY and AMPEROMETRIC TITRATIONS
AMPEROMETRY and AMPEROMETRIC TITRATIONSAMPEROMETRY and AMPEROMETRIC TITRATIONS
AMPEROMETRY and AMPEROMETRIC TITRATIONS
 
Potentiometric - Pharmaceutical Analysis (101T)
Potentiometric - Pharmaceutical Analysis (101T)Potentiometric - Pharmaceutical Analysis (101T)
Potentiometric - Pharmaceutical Analysis (101T)
 
Polarography
PolarographyPolarography
Polarography
 
Potentiometry ppt
Potentiometry pptPotentiometry ppt
Potentiometry ppt
 
Polarography[1]
Polarography[1]Polarography[1]
Polarography[1]
 
PA-I Condutometry.(HRB)
PA-I Condutometry.(HRB)PA-I Condutometry.(HRB)
PA-I Condutometry.(HRB)
 
Polarography
PolarographyPolarography
Polarography
 
Polarography Principle, instrumentation, Applications.pptx
Polarography Principle, instrumentation, Applications.pptxPolarography Principle, instrumentation, Applications.pptx
Polarography Principle, instrumentation, Applications.pptx
 
potentiometry
potentiometrypotentiometry
potentiometry
 
Voltammetry
VoltammetryVoltammetry
Voltammetry
 
voltammetry basics.pptx
voltammetry basics.pptxvoltammetry basics.pptx
voltammetry basics.pptx
 
Complexometric titration 2019-20
Complexometric titration 2019-20Complexometric titration 2019-20
Complexometric titration 2019-20
 
Lect. 2 DMG structure-uses-Advantages-limitation
Lect. 2 DMG  structure-uses-Advantages-limitationLect. 2 DMG  structure-uses-Advantages-limitation
Lect. 2 DMG structure-uses-Advantages-limitation
 

Similar to Potentiometry

potentiometry-180713090143.pdf
potentiometry-180713090143.pdfpotentiometry-180713090143.pdf
potentiometry-180713090143.pdfPriyanka Yadav
 
Potentiometery BP 1st year.pptx
Potentiometery BP 1st year.pptxPotentiometery BP 1st year.pptx
Potentiometery BP 1st year.pptxshwetasingh31652
 
Pharmaceutical Analysis Potentiometery BP
Pharmaceutical Analysis Potentiometery BPPharmaceutical Analysis Potentiometery BP
Pharmaceutical Analysis Potentiometery BPshwetasingh31652
 
Potentiometrynew 170227172008
Potentiometrynew 170227172008Potentiometrynew 170227172008
Potentiometrynew 170227172008Dorothy Nyamai
 
Ver1-Potentiometry (3rd +4th Lects).ppt
Ver1-Potentiometry (3rd +4th Lects).pptVer1-Potentiometry (3rd +4th Lects).ppt
Ver1-Potentiometry (3rd +4th Lects).pptMohamedWefqi
 
POTENTIOMETRY.pdf
POTENTIOMETRY.pdfPOTENTIOMETRY.pdf
POTENTIOMETRY.pdfSaqibShaik2
 
Ion sensitive electrode &amp; gas sensitive electrode..
Ion sensitive electrode &amp; gas sensitive electrode..Ion sensitive electrode &amp; gas sensitive electrode..
Ion sensitive electrode &amp; gas sensitive electrode..vishnupriya456
 
potentiometry & ion selective electode
potentiometry & ion selective electodepotentiometry & ion selective electode
potentiometry & ion selective electodersgokani
 
Engineering Chemistry Module 1 : Reference Electrodes
Engineering Chemistry Module 1 : Reference ElectrodesEngineering Chemistry Module 1 : Reference Electrodes
Engineering Chemistry Module 1 : Reference ElectrodesSwastika Das
 
Second lect Potentiometry.ppt
Second lect Potentiometry.pptSecond lect Potentiometry.ppt
Second lect Potentiometry.pptMohamedWefqi
 
Potentiometry1 for mpharm ist sem notes
Potentiometry1 for mpharm ist sem notes Potentiometry1 for mpharm ist sem notes
Potentiometry1 for mpharm ist sem notes prakash64742
 
Electrochemistry, electrophoresis, ise
Electrochemistry, electrophoresis, iseElectrochemistry, electrophoresis, ise
Electrochemistry, electrophoresis, iseAngelica Nhoj Gemora
 
ppt uit 2 link -final - (1.1.23) - Copy.pptx
ppt uit 2 link -final - (1.1.23) - Copy.pptxppt uit 2 link -final - (1.1.23) - Copy.pptx
ppt uit 2 link -final - (1.1.23) - Copy.pptxKundanBhatkar
 
Potentiometry, voltamemtry and conductometry
Potentiometry, voltamemtry and conductometryPotentiometry, voltamemtry and conductometry
Potentiometry, voltamemtry and conductometryapeksha40
 

Similar to Potentiometry (20)

potentiometry-180713090143.pdf
potentiometry-180713090143.pdfpotentiometry-180713090143.pdf
potentiometry-180713090143.pdf
 
1 Potentiometry
1  Potentiometry1  Potentiometry
1 Potentiometry
 
potentiometry
potentiometrypotentiometry
potentiometry
 
Potentiometery BP 1st year.pptx
Potentiometery BP 1st year.pptxPotentiometery BP 1st year.pptx
Potentiometery BP 1st year.pptx
 
Pharmaceutical Analysis Potentiometery BP
Pharmaceutical Analysis Potentiometery BPPharmaceutical Analysis Potentiometery BP
Pharmaceutical Analysis Potentiometery BP
 
Potentiometrynew 170227172008
Potentiometrynew 170227172008Potentiometrynew 170227172008
Potentiometrynew 170227172008
 
Ver1-Potentiometry (3rd +4th Lects).ppt
Ver1-Potentiometry (3rd +4th Lects).pptVer1-Potentiometry (3rd +4th Lects).ppt
Ver1-Potentiometry (3rd +4th Lects).ppt
 
POTENTIOMETRY.pdf
POTENTIOMETRY.pdfPOTENTIOMETRY.pdf
POTENTIOMETRY.pdf
 
Ion sensitive electrode &amp; gas sensitive electrode..
Ion sensitive electrode &amp; gas sensitive electrode..Ion sensitive electrode &amp; gas sensitive electrode..
Ion sensitive electrode &amp; gas sensitive electrode..
 
potentiometry & ion selective electode
potentiometry & ion selective electodepotentiometry & ion selective electode
potentiometry & ion selective electode
 
Potentiometry ppt By Chand.pptx
Potentiometry ppt By Chand.pptxPotentiometry ppt By Chand.pptx
Potentiometry ppt By Chand.pptx
 
Engineering Chemistry Module 1 : Reference Electrodes
Engineering Chemistry Module 1 : Reference ElectrodesEngineering Chemistry Module 1 : Reference Electrodes
Engineering Chemistry Module 1 : Reference Electrodes
 
potentiometery
potentiometerypotentiometery
potentiometery
 
Second lect Potentiometry.ppt
Second lect Potentiometry.pptSecond lect Potentiometry.ppt
Second lect Potentiometry.ppt
 
Potentiometry1 for mpharm ist sem notes
Potentiometry1 for mpharm ist sem notes Potentiometry1 for mpharm ist sem notes
Potentiometry1 for mpharm ist sem notes
 
Electrochemistry, electrophoresis, ise
Electrochemistry, electrophoresis, iseElectrochemistry, electrophoresis, ise
Electrochemistry, electrophoresis, ise
 
ppt uit 2 link -final - (1.1.23) - Copy.pptx
ppt uit 2 link -final - (1.1.23) - Copy.pptxppt uit 2 link -final - (1.1.23) - Copy.pptx
ppt uit 2 link -final - (1.1.23) - Copy.pptx
 
Potentiometry.pptx
Potentiometry.pptxPotentiometry.pptx
Potentiometry.pptx
 
Potentiometry, voltamemtry and conductometry
Potentiometry, voltamemtry and conductometryPotentiometry, voltamemtry and conductometry
Potentiometry, voltamemtry and conductometry
 
Ion selective electrode (hw)85
Ion selective electrode (hw)85Ion selective electrode (hw)85
Ion selective electrode (hw)85
 

Recently uploaded

AmericanHighSchoolsprezentacijaoskolama.
AmericanHighSchoolsprezentacijaoskolama.AmericanHighSchoolsprezentacijaoskolama.
AmericanHighSchoolsprezentacijaoskolama.arsicmarija21
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designMIPLM
 
Full Stack Web Development Course for Beginners
Full Stack Web Development Course  for BeginnersFull Stack Web Development Course  for Beginners
Full Stack Web Development Course for BeginnersSabitha Banu
 
Introduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher EducationIntroduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher Educationpboyjonauth
 
Grade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptxGrade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptxChelloAnnAsuncion2
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Mark Reed
 
EPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptxEPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptxRaymartEstabillo3
 
Quarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up FridayQuarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up FridayMakMakNepo
 
Romantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptxRomantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptxsqpmdrvczh
 
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...JhezDiaz1
 
Hierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of managementHierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of managementmkooblal
 
ENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choomENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choomnelietumpap1
 
Atmosphere science 7 quarter 4 .........
Atmosphere science 7 quarter 4 .........Atmosphere science 7 quarter 4 .........
Atmosphere science 7 quarter 4 .........LeaCamillePacle
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTiammrhaywood
 
Roles & Responsibilities in Pharmacovigilance
Roles & Responsibilities in PharmacovigilanceRoles & Responsibilities in Pharmacovigilance
Roles & Responsibilities in PharmacovigilanceSamikshaHamane
 
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxMULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxAnupkumar Sharma
 
ROOT CAUSE ANALYSIS PowerPoint Presentation
ROOT CAUSE ANALYSIS PowerPoint PresentationROOT CAUSE ANALYSIS PowerPoint Presentation
ROOT CAUSE ANALYSIS PowerPoint PresentationAadityaSharma884161
 
Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17Celine George
 
How to Configure Email Server in Odoo 17
How to Configure Email Server in Odoo 17How to Configure Email Server in Odoo 17
How to Configure Email Server in Odoo 17Celine George
 

Recently uploaded (20)

AmericanHighSchoolsprezentacijaoskolama.
AmericanHighSchoolsprezentacijaoskolama.AmericanHighSchoolsprezentacijaoskolama.
AmericanHighSchoolsprezentacijaoskolama.
 
Keynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-designKeynote by Prof. Wurzer at Nordex about IP-design
Keynote by Prof. Wurzer at Nordex about IP-design
 
Full Stack Web Development Course for Beginners
Full Stack Web Development Course  for BeginnersFull Stack Web Development Course  for Beginners
Full Stack Web Development Course for Beginners
 
Introduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher EducationIntroduction to ArtificiaI Intelligence in Higher Education
Introduction to ArtificiaI Intelligence in Higher Education
 
Grade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptxGrade 9 Q4-MELC1-Active and Passive Voice.pptx
Grade 9 Q4-MELC1-Active and Passive Voice.pptx
 
Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)Influencing policy (training slides from Fast Track Impact)
Influencing policy (training slides from Fast Track Impact)
 
EPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptxEPANDING THE CONTENT OF AN OUTLINE using notes.pptx
EPANDING THE CONTENT OF AN OUTLINE using notes.pptx
 
Quarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up FridayQuarter 4 Peace-education.pptx Catch Up Friday
Quarter 4 Peace-education.pptx Catch Up Friday
 
Romantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptxRomantic Opera MUSIC FOR GRADE NINE pptx
Romantic Opera MUSIC FOR GRADE NINE pptx
 
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
ENGLISH 7_Q4_LESSON 2_ Employing a Variety of Strategies for Effective Interp...
 
Hierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of managementHierarchy of management that covers different levels of management
Hierarchy of management that covers different levels of management
 
ENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choomENGLISH6-Q4-W3.pptxqurter our high choom
ENGLISH6-Q4-W3.pptxqurter our high choom
 
Atmosphere science 7 quarter 4 .........
Atmosphere science 7 quarter 4 .........Atmosphere science 7 quarter 4 .........
Atmosphere science 7 quarter 4 .........
 
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPTECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
ECONOMIC CONTEXT - LONG FORM TV DRAMA - PPT
 
OS-operating systems- ch04 (Threads) ...
OS-operating systems- ch04 (Threads) ...OS-operating systems- ch04 (Threads) ...
OS-operating systems- ch04 (Threads) ...
 
Roles & Responsibilities in Pharmacovigilance
Roles & Responsibilities in PharmacovigilanceRoles & Responsibilities in Pharmacovigilance
Roles & Responsibilities in Pharmacovigilance
 
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptxMULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
MULTIDISCIPLINRY NATURE OF THE ENVIRONMENTAL STUDIES.pptx
 
ROOT CAUSE ANALYSIS PowerPoint Presentation
ROOT CAUSE ANALYSIS PowerPoint PresentationROOT CAUSE ANALYSIS PowerPoint Presentation
ROOT CAUSE ANALYSIS PowerPoint Presentation
 
Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17Computed Fields and api Depends in the Odoo 17
Computed Fields and api Depends in the Odoo 17
 
How to Configure Email Server in Odoo 17
How to Configure Email Server in Odoo 17How to Configure Email Server in Odoo 17
How to Configure Email Server in Odoo 17
 

Potentiometry

  • 1. POTENTIOMETRY Presented by G.Pavani Y17MPHPA426 Chalapathi institute of pharmaceutical sciences,Lam,Guntur(Dt).
  • 2. pH is a Potentiometric Measurement The Measuring System consists of a pH Measuring Electrode (indicating electrode) and Reference Electrode The Potential Difference Between the Two Electrodes is a Function of the pH Value of the Measured Solution. The Analyte Solution Must Be Conductive and is Part of the Electrical Circuit.
  • 3. POTENTIOMETRIC ANALYSIS  Based on potential measurement of electrochemical cells without any appreciable current  The use of electrodes to measure voltages from chemical reactions
  • 4. DEFINITION Potentiometry: “Measuring the potential or Emf of a solution by using the set of Indicator electrode and reference electrode”.
  • 5. The potential(E)of a metal elctrode at25 C,immersed into a solution of its own ions is given by E=E0 + 0.0592 × logc n Where, E0 = standard potential of the electrode n = valency of ions c = concentration of ions Nernest equation
  • 6. COMPONENTS OF A POTENTIOMETRIC CELL 1. Reference electrode 2. Salt bridge 3. Analyte 4. Indicator electrode RE SB A IE – Eref + Ej + Eind
  • 7. REFERENCE ELECTRODE • Half-cell with known potential (Eref) • Left hand electrode (by convention) • Easily assembled • Rugged • Insensitive to analyte concentration ▫ Reversible and obeys Nernst equation ▫ Constant potential ▫ Returns to original potential
  • 8. INDICATOR ELECTRODE  Generates a potential (Eind) that depends on analyte concentration  Selective  Rapid and reproducible response
  • 9. SALT BRIDGE  Prevents mixing up of analyte components  Generates potential (Ej) = negligible
  • 10.
  • 11. REFERENCE ELECTRODES 1. Standard Hydrogen Electrode 2. Saturated Calomel Reference Electrode 3. Silver/Silver Chloride -Reference Electrode
  • 12. HYDROGEN ELECTRODE o It can be used as Indicator as well as Reference eletrode. o It can be consist of platinum foil coated with platinum balck and has a wire contacts through a mercury. o This assembly is enclosed in a glass covering. o Hydrogen gas is passed at 1atmospheric pressure continuously. o (Pt (H2 (1 atm), H+ (1M)
  • 13. o Then eletrode is dipped into the standard acid /unknown solution. o All the times surface of the electrode and the solution should be saturated with the gas. o potential , o E=E0H+0.0592log[H+] =E0H-0.0592pH(pH=-log [H+]  E=-0.0592 pH.  E0=std Eof H2 electrode ,taken as 0
  • 14. Advantages and Disadvantages of H2Electrode:  Advantages:  It can be used over the entire pH.  Itcan be used as a reference electrode when dipped with standard acid solution and as a indicator electrode when dipped into a sample solution.  It is the primary reference standard against which the potentials of other electrodes are measured.  Disadvantages  It is effected by the presence of oxidizing agent and reducing agent.  It is rather difficult to regulate the pressure of H2 gas to be exactly 1 atm throughout the experiment.  Platinum foil gets easily poisoned by the impurities present in the H2 gas and Hcl solution.
  • 15. Saturated calomel elctrode • It consist of inner jacket and outer sleeve • Inner tube has a wire contact with mercury(Hg) and plugged with a mixture of calomel(Hg2cl2)and KCL. • This is surrounded by an outer sleeve • Tip is filled with Crystals of KCL and porous plug of asbestos. • The space between inner jacket and outer sleeve is filled with saturated KCL/1N KCL/0.1 N KCL. • Potential of the electrode depends on • The Concentration of the KCL Solution. And Temperature.
  • 16. • Merits: Easy of construction Stability of Potential. • Demerits: Dependent on temp Toxic • Applications: Used in pH Measurement Equation: Hg2Cl2(s)+2e-2Hg(l)+2Cl-(aq) • 0.2444 V at 25C
  • 17. Silver –Silver Chloride electrode It is also widely used reference electrode, Because,It is simple In expensive Very stable Non –toxic. It is mainly used with Saturated KCL Electrode (kcl electrolyte) but canbe used with low concentration such as 1MKCL and even directly in sea water. “Ag-wire coated electrolytically with AgCl2 and dipped into KCL
  • 18. Potential depends on the concentration of the KCL and temperature. AgAgCl (satd),KCl (satd) AgCl(s) + e-Ag(s)+Cl-(aq) E = 0.199 V Advantage: Easy to use  Dis advantage: Difficult to prepare.
  • 19. LIQUID JUNCTION POTENTIAL  Liquid junction - interface between two solutions containing different electrolytes or different concentrations of the same electrolyte  A junction potential occurs at every liquid junction.  Caused by unequal mobilities of the + and - ions.
  • 20. INDICATOR ELECTRODES I. Metallic IE A. Electrodes of the First Kind B. Electrodes of the Second Kind C. Inert Metallic Electrodes (for Redox Systems) II. Membrane IE/Ion –Selective Electrodes. A. Glass pH IE B. Glass IE for other cations C. Liquid Membrane IE D. Crystalline-Membrane IE III.Gas Sensing Probes/Gas Sensing Electrode.
  • 22. ELECTRODES OF THE FIRST KIND  Pure metal electrode in direct equilibrium with its cation  Metal is in contact with a solution containing its cation. M+n(aq) + ne-  M(s)
  • 23. DISADVANTAGES OF FIRST KIND ELECTRODES  Not very selective  Ag+ interferes with Cu+2  May be pH dependent  Zn and Cd dissolve in acidic solutions  Easily oxidized (deaeration required)  Non-reproducible response
  • 24. ELECTRODES OF THE SECOND KIND  Respond to anions by forming precipitates or stable complex  Examples: 1. Ag electrode for Cl- determination 2. Hg electrode for EDTA determination
  • 25. INERT METALLIC (REDOX) ELECTRODES  Inert conductors that respond to redox systems  Electron source or sink  An inert metal in contact with a solution containing the soluble oxidized and reduced forms of the redox half-reaction.  May not be reversible  Examples:  Pt, Au, Pd, C
  • 26. ION SELECTIVE ELECTRODES  Other synonym:Membrane electrodes  Definition: “ ISE are known as specific ion electrode, it is a membrane that Converts the activity of a specific ion dissolved in a solution into an electrode Potential”.  The voltage is theoritically dependent on the negative logerithem of the ionic activity, according to the Nernest equation.
  • 27. Uses: ISE are used in analytical chrmistry,bio-chemical/ biophysical research. whwre, measurements of ionic concentration in aqueous solutions are required. TYPES OF ISE: 1.Glass Membrane electrode 2.Liquid-Liquid electrode/Liquid membrane electrode. 3.Crystal Membrane electrode. 4.Gas sensing electrode.
  • 29. Combined PH glass electrodepH measurement system
  • 30. Working principle of pH glass membrane electrode Principle of pH meter
  • 31. STYLE OF GLASS ELECTRODE • The glass membrane itself is not limited to any configuration or shape; its only requirement is contact with solution. • Therefore, different styles of glass electrodes have evolved to maximize pH sensing ability and extend longevity in some of the more difficult applications.
  • 32. PROPERTIES OF GLASS PH ELECTRODE  Potential not affected by the presence of oxidizing or reducing agents  Operates over a wide pH range  Fast response  Functions well in physiological systems  Very selective  Long lifespan
  • 33. Theory of the glass membrane potential  For the electrode to become operative, it must be soaked in water.  During this process, the outer surface of the membrane becomes hydrated.  When it is so, the sodium ions are exchanged for protons in the solution:  The protons are free to move and exchange with other ions. Charge is slowly carried by migration of Na+ across glass membrane Potential is determined by external [H+]
  • 34. ALKALINE ERROR  Exhibited at pH > 9  Electrodes respond to H+ and alkali cations  C,D,E and F: measured value is < true value  Electrode also responds to other cations  Higher pH at lower [Na+]
  • 35. ACID ERROR  Exhibited at pH < 0.5  pH readings are higher (curves A and B)  Saturation effect with respect to H+
  • 36. 2.LIQUID MEMBRANE ELECTRODES • Potential develops across the interface between the analyte solution and a liquid ion exchanger (that bonds with analyte) • Similar to a pH electrode except that the membrane is an organic polymer saturated with a liquid ion exchanger • Used for polyvalent ions as well as some anions • Example: • Calcium dialkyl phosphate insoluble in water, but binds Ca2+ strongly
  • 38.
  • 39. CHARACTERISTICS OF CA+2 ISE  Relatively high sensitivity  Low LOD  Working pH range: 5.5 – 11  Relevant in studying physiological processes
  • 40. A K+-SELECTIVE ELECTRODE  Sensitive membrane consists of valinomycin, an antibiotic
  • 41. 3.CRYSTALLINE-MEMBRANE ELECTRODES  Solid state electrodes  Usually ionic compound  Crushed powder, melted and formed  Sometimes doped to increase conductivity  Operation similar to glass membrane
  • 42. CRYSTALLINE-MEMBRANE ELECTRODES:  AgX membrane: Determination of X-  Ag2S membrane: Determination of S-2  LaF3 membrane: Determination of F-
  • 43. EX:F- SELECTIVE ELECTRODE  A LaF3 is doped with EuF2.  Eu2+ has less charge than the La3+, so an anion vacancy occurs for every Eu2+.  A neighboring F- can jump into the vacancy, thereby moving the vacancy to another site.  Repetition of this process moves F- through the lattice.
  • 45. 4.GAS SENSING ELECTRODE  A galvanic cell whose potential is related to the concentration of a gas in solution  Consist of RE, ISE and electrolyte solution  A thin gas-permeable membrane (PTFE) serves as a barrier between internal and analyte solutions  Allows small gas molecules to pass and dissolve into internal solution  O2, NH3/NH4 +, and CO2/HCO3 -/CO3 2-
  • 46. FIG: GAS SENSING ELECTRODE
  • 47. DIRECT POTENTIOMETRY • A rapid and convenient method of determining the activity of cations/anions
  • 48. POTENTIOMETRIC MEASUREMENT 1. Calibration Method 2. Standard Addition Method
  • 49. POTENTIOMETRIC TITRATION  Involves measurement of the potential of a suitable indicator electrode as a function of titrant volume  Provides MORE RELIABLE data than the usual titration method  Useful with colored/turbid solutions  May be automated  More time consuming
  • 51. POTENTIOMETRIC TITRATIONS  Is a technique similar to direct titration of a redox reaction.  No indicator is used, (instead the potential across the analyte) typically an electrolyte solution is measured.  To do this, two electrodes are used, an indicator electrode and a reference electrode.  The indicator electrode forms an electrochemical half cell with the interested ions in the test solution.  The reference electrode forms the other half cell, holding a consistent electrical potential.
  • 52. WHEN POTENTIOMETRIC TITRATIONS IS USED?  It is used when the endpoints are very difficult to determine either when: 1- very diluted solution. 2-coloured and turbid solution. 3-absence of a suitable indicator.
  • 53. INSTRUMENTS PH meter Reference electrode. Indicator electrode. Voltmeter which measures the potential difference.  Magnetic stirrer. hot plate ( use the stirrer and make sure heat is off ). magnet capsule . •Glass (burrete and beaker)
  • 54.
  • 55. of 0.1 N NaOH Potentiometric titration curve of (0.1 N) NaOH against (?? N ) acetic acid :
  • 56.  Do not place the electrodes anywhere except attached to the electrode holder.  At the end of the experiment rinse the electrodes and place each one in its housing as required.  Never touch the glass part of the electrode with anything except soft tissue paper. While in use, the bulb of the glass electrode should be immersed in solution. IMORTANT TO KNOW
  • 57. o For short-term storage the combined glass electrode should be immersed in solution of 2 M KCl. o Buffer solutions of known pH are used for the pH calibration. o For high accuracy, calibration and measurements are to be performed at the same temperature.
  • 58. 1-the outside surface of the glass membrane is in contact with the sample being measured. 2-and the inside surface contact the inner filling solution . 3-A complex mechanism at each glass liquid interface defines the potential of the pH glass electrode. 4-While the pH inner glass /filling solution potential is constant , the outside potential varies based on the hydrogen ion concentration in the sample.
  • 59. Applications of Potentiometry: 1. Direct potentiometry:  A rapid and convinient method of detecting the activity of cations and anions.  The technique used in this method is a comparison of the potential developed by the indicator electrode when it is immersed in the solution with that when it is immersed in standard solution of the analyte. 2. The calibration curve method:  It is applied for determination of substance by direct potentiometry.  In which we plot potential of the cell Vs a series of standard solution of extragrade of the substance to be determined.
  • 60.  Then measure the potential prodused when using the unknown solution and from the calibration curve we can obtain its concentrations. 3. Environmental chemistry:  Pollution monitoring: CN,F,S,Li,Na, etc…..in effluents and natural water 4. Agriculture : NO3,Cl,I,K,Ca,CN, in Soil, plant material, Fertilizers, Feedstuffs.
  • 61.
  • 62. 5 . Food processing: No3,No2 in Meat, and preservatives. 6. Florin in drinking water and other drinkers. 7. Salt content of Meat,Fish,Dairy products,Fruits,Juices,Brewing Solutions. 8. Potentiometric titrations:  Acid-Basetitrations (aqueous and non aqueous)  Redox titrations  Diazotisation titrations  Precipitation titrations  Complexometric titrations  Dead stop end point technique.
  • 63. 1.Acid –base titrations: Titrations can be done in aqueous and non-aqueous medium. E+k-0.0592pH. Ex:-Aqueous medium:any strength-0.01N,0.1N,1N. o Acid-base combinations: Weak acid - Weak base Weak acid-Strong base (CH3COOH Vs NH4OH) (CH3COOH-NAOH) Strong acid-Strong base Strong acid-Weak base (HCL-NAOH) (HCL-NH4OH) oMixture of acids Vs bases: (CH3COOH+HCL)Vs NAOH oMixture of bases Vs acids: (NH4OH+NAOH) Vs HCL. oPoly basis acids Vs bases: Citric acid Vs NAOH Tartaric acid Vs NAOH.
  • 64. • Non aqueous medium:  Weak acidVs pottasium(KOME)/Lithium methoxide(Liome)  Ex:-Barbituric acid Vs LiOMe  Weak bases Vs perchloric acid  Ex:-Ephedrine Hydrochloride /Q.sulphate/Metronidazole/Chloroquine phosphate Vs 0.1NHCLO4.  Indicator electrode:Glass electrode  Reference electrode:SCE
  • 65. 2. Redox-titrations:  Reaction:Ce4+ + Fe2+ Ce3+ + Fe3+  Ce4+ is an oxydising agent which oxidises Fe2+ (ferrous) to Fe3+(ferric ion), in this process Ce4+(cerric) gets redused to Ce3+ (cerrous ions).  E =E0 + 0.0592/n.log(ox)/(Red).  Where,E0= std potential.  n= no.of electrons involved in the reaction,  (ox)= conc. Of oxidant  (Red)= conc of reductant.
  • 66.  Reference electrode:SCE,Ag-Agcl2 electrode.  Indicator electrode:platinum wire or foil. mv scale is used for end point detection. Ex:-Ferrous ammonium sulphate in dilute H2SO4VsKMNO4/K2Cr2O7. 3.Diazotisation titrations:  Drugs or substances containing aromatic amino group can be titrated against sodium nitrate in acidic medium.  Result in the formation of diazonium salt this type of titration is called as Diazotisation titration.
  • 67.  End point detecting:by  a)Starch iodide paper(externalindicator method)  Potentiometric method of detecting end point.  Reference electrode:SCE  Indicator electrode:Glass electrode.  Ex:Alkaloids,Amines,Sulpha drugs which contain primary aromatic amino group can be titrated against0.1N sodium Nitrate in HCl .
  • 68. 4)Precipitation titrations:  For quantitative determination of several ions or elements precipitating agents are used as titrants,  End point is determined by potentiometric method.  E=E0+0.0592/n.log[Mn+] where, [Mn+]=conc of ions n= electronic state.  Reference electrode:SCE,H2,Ag-AgCl2 electrode  Indicator electrode:Silver wire electrode.
  • 69.  Ex: Determination of Hg,Ag,Pb,Cu, and other ions using precipitants to form insoluble salts. 5)Complexometric titrations:  Metalic ions (divalent)can be titrated against disodium edetate solutions by potentiometric method  Measurements are made inmv scale.
  • 70. • Reference electrode:SCE/ any other. • Indicator electrode:Ag / Hg electrode. • Ex:-Di and Trivalent ions. (mix of Bi3+,Cd2+,Ca2+ by using EDTA). Applications of Potentiometer as (I.Pmethods )
  • 71. S.NO DRUGS TITRANT INDICATOR ELECTRODE REFERENCE ELECTRODE 1 Amoxicillin sodium Mercuric nitrate Pt/Hg Hg-mercurous sulphate 2 Acebutalol HCl NaOH Glass SCE/Ag-AgCl 3 Dextromorphan HCl NaOH Glass SCE/Ag-AgCl 4 DiphenoxylateHCl Ethanolic NaOH Glass SCE/Ag-AgCl 5 Disulfiram Ag2NO3 Silver SCE 6 Hydralazine HCl Potassium iodate platinum SCE 7 Lomustine silvernitrate silver Calomel 8 Metoclopromide HCl NaOH Glass SCE 9 Naldixic acid Ethanolic sodium of hydroxide Glass Ag-AgCl 10 Phenobarbitone sodium NaOH Glass SCE 11 Promithazine HCl NaOH Glass SCE 12 propranalololHCl NaOH Glass SCE 13 Sodium stibogluconate injection Ferric ammonium sulphate pt Ag-AgCl