ICP-MS (inductively coupled plasma mass spectrometry) is an analytical technique used to detect and measure elements in chemical samples. It works by ionizing atoms from a sample using an inductively coupled plasma and then detecting the mass-to-charge ratios of the resulting ions using a mass spectrometer. ICP-MS can detect elements at concentrations as low as parts per trillion and has a wide working range of nine orders of magnitude. It is capable of isotopic analysis and multi-element detection across most of the periodic table. ICP-MS has various applications in fields like medicine, materials science, and environmental analysis.
Flame Emission Spectroscopy (FES) has been a widespread analytical tool for research and education. Flame Emission Spectroscopy is so named because of the use of the flame, to provide the energy of excitation to atoms introduced into the flame. Flame Emission Spectroscopy is also called Flame Photometry. Flame Emission Spectroscopy is based upon those particles that are electronically excited in the medium.
It is a multi-element analysis technique where The ICP source converts the atoms of the elements in the sample to ions. These ions are then separated and detected by the mass spectrometer
Flame Emission Spectroscopy (FES) has been a widespread analytical tool for research and education. Flame Emission Spectroscopy is so named because of the use of the flame, to provide the energy of excitation to atoms introduced into the flame. Flame Emission Spectroscopy is also called Flame Photometry. Flame Emission Spectroscopy is based upon those particles that are electronically excited in the medium.
It is a multi-element analysis technique where The ICP source converts the atoms of the elements in the sample to ions. These ions are then separated and detected by the mass spectrometer
The presentation is about Inductively coupled plasma mass spectrometry (ICP-MS) which is a type of mass spectrometry that is capable of detecting metals and several non-metals at concentrations as low as parts per billion.
A short lecture about Atomic Spectroscopy: Flame Photometry, Atomic Absorption, and Atomic Emission with Coupled Plasma (FP, AA and ICP-AES). Presented at 28.03.2011, Faculty of Agriculture, Hebrew University of Jerusalem, by Vasiliy Rosen, M.Sc.
The presentation is about Inductively coupled plasma mass spectrometry (ICP-MS) which is a type of mass spectrometry that is capable of detecting metals and several non-metals at concentrations as low as parts per billion.
A short lecture about Atomic Spectroscopy: Flame Photometry, Atomic Absorption, and Atomic Emission with Coupled Plasma (FP, AA and ICP-AES). Presented at 28.03.2011, Faculty of Agriculture, Hebrew University of Jerusalem, by Vasiliy Rosen, M.Sc.
Here are the lecture notes from the presentation titled 'ICP-OES/MS Analysis: Advancements, Limitations, and Future Applications in Soil and Water Research,' delivered to a group of researchers affiliated with the Soil & Water Department, Faculty of Agriculture, Hebrew University of Jerusalem (Seagram Center) in 2023. The aim was to explore advanced technologies in elemental analysis and their application to soil and water research. The Lecture Notes Brochure (22 pages) can serve as a concise guide to ICP-OES/MS for researchers and students, assisting them in selecting the appropriate technique for their projects
Seminar of U.V. Spectroscopy by SAMIR PANDASAMIR PANDA
Spectroscopy is a branch of science dealing the study of interaction of electromagnetic radiation with matter.
Ultraviolet-visible spectroscopy refers to absorption spectroscopy or reflect spectroscopy in the UV-VIS spectral region.
Ultraviolet-visible spectroscopy is an analytical method that can measure the amount of light received by the analyte.
Phenomics assisted breeding in crop improvementIshaGoswami9
As the population is increasing and will reach about 9 billion upto 2050. Also due to climate change, it is difficult to meet the food requirement of such a large population. Facing the challenges presented by resource shortages, climate
change, and increasing global population, crop yield and quality need to be improved in a sustainable way over the coming decades. Genetic improvement by breeding is the best way to increase crop productivity. With the rapid progression of functional
genomics, an increasing number of crop genomes have been sequenced and dozens of genes influencing key agronomic traits have been identified. However, current genome sequence information has not been adequately exploited for understanding
the complex characteristics of multiple gene, owing to a lack of crop phenotypic data. Efficient, automatic, and accurate technologies and platforms that can capture phenotypic data that can
be linked to genomics information for crop improvement at all growth stages have become as important as genotyping. Thus,
high-throughput phenotyping has become the major bottleneck restricting crop breeding. Plant phenomics has been defined as the high-throughput, accurate acquisition and analysis of multi-dimensional phenotypes
during crop growing stages at the organism level, including the cell, tissue, organ, individual plant, plot, and field levels. With the rapid development of novel sensors, imaging technology,
and analysis methods, numerous infrastructure platforms have been developed for phenotyping.
This presentation explores a brief idea about the structural and functional attributes of nucleotides, the structure and function of genetic materials along with the impact of UV rays and pH upon them.
Observation of Io’s Resurfacing via Plume Deposition Using Ground-based Adapt...Sérgio Sacani
Since volcanic activity was first discovered on Io from Voyager images in 1979, changes
on Io’s surface have been monitored from both spacecraft and ground-based telescopes.
Here, we present the highest spatial resolution images of Io ever obtained from a groundbased telescope. These images, acquired by the SHARK-VIS instrument on the Large
Binocular Telescope, show evidence of a major resurfacing event on Io’s trailing hemisphere. When compared to the most recent spacecraft images, the SHARK-VIS images
show that a plume deposit from a powerful eruption at Pillan Patera has covered part
of the long-lived Pele plume deposit. Although this type of resurfacing event may be common on Io, few have been detected due to the rarity of spacecraft visits and the previously low spatial resolution available from Earth-based telescopes. The SHARK-VIS instrument ushers in a new era of high resolution imaging of Io’s surface using adaptive
optics at visible wavelengths.
Earliest Galaxies in the JADES Origins Field: Luminosity Function and Cosmic ...Sérgio Sacani
We characterize the earliest galaxy population in the JADES Origins Field (JOF), the deepest
imaging field observed with JWST. We make use of the ancillary Hubble optical images (5 filters
spanning 0.4−0.9µm) and novel JWST images with 14 filters spanning 0.8−5µm, including 7 mediumband filters, and reaching total exposure times of up to 46 hours per filter. We combine all our data
at > 2.3µm to construct an ultradeep image, reaching as deep as ≈ 31.4 AB mag in the stack and
30.3-31.0 AB mag (5σ, r = 0.1” circular aperture) in individual filters. We measure photometric
redshifts and use robust selection criteria to identify a sample of eight galaxy candidates at redshifts
z = 11.5 − 15. These objects show compact half-light radii of R1/2 ∼ 50 − 200pc, stellar masses of
M⋆ ∼ 107−108M⊙, and star-formation rates of SFR ∼ 0.1−1 M⊙ yr−1
. Our search finds no candidates
at 15 < z < 20, placing upper limits at these redshifts. We develop a forward modeling approach to
infer the properties of the evolving luminosity function without binning in redshift or luminosity that
marginalizes over the photometric redshift uncertainty of our candidate galaxies and incorporates the
impact of non-detections. We find a z = 12 luminosity function in good agreement with prior results,
and that the luminosity function normalization and UV luminosity density decline by a factor of ∼ 2.5
from z = 12 to z = 14. We discuss the possible implications of our results in the context of theoretical
models for evolution of the dark matter halo mass function.
Comparing Evolved Extractive Text Summary Scores of Bidirectional Encoder Rep...University of Maribor
Slides from:
11th International Conference on Electrical, Electronics and Computer Engineering (IcETRAN), Niš, 3-6 June 2024
Track: Artificial Intelligence
https://www.etran.rs/2024/en/home-english/
DERIVATION OF MODIFIED BERNOULLI EQUATION WITH VISCOUS EFFECTS AND TERMINAL V...Wasswaderrick3
In this book, we use conservation of energy techniques on a fluid element to derive the Modified Bernoulli equation of flow with viscous or friction effects. We derive the general equation of flow/ velocity and then from this we derive the Pouiselle flow equation, the transition flow equation and the turbulent flow equation. In the situations where there are no viscous effects , the equation reduces to the Bernoulli equation. From experimental results, we are able to include other terms in the Bernoulli equation. We also look at cases where pressure gradients exist. We use the Modified Bernoulli equation to derive equations of flow rate for pipes of different cross sectional areas connected together. We also extend our techniques of energy conservation to a sphere falling in a viscous medium under the effect of gravity. We demonstrate Stokes equation of terminal velocity and turbulent flow equation. We look at a way of calculating the time taken for a body to fall in a viscous medium. We also look at the general equation of terminal velocity.
What is greenhouse gasses and how many gasses are there to affect the Earth.moosaasad1975
What are greenhouse gasses how they affect the earth and its environment what is the future of the environment and earth how the weather and the climate effects.
The ability to recreate computational results with minimal effort and actionable metrics provides a solid foundation for scientific research and software development. When people can replicate an analysis at the touch of a button using open-source software, open data, and methods to assess and compare proposals, it significantly eases verification of results, engagement with a diverse range of contributors, and progress. However, we have yet to fully achieve this; there are still many sociotechnical frictions.
Inspired by David Donoho's vision, this talk aims to revisit the three crucial pillars of frictionless reproducibility (data sharing, code sharing, and competitive challenges) with the perspective of deep software variability.
Our observation is that multiple layers — hardware, operating systems, third-party libraries, software versions, input data, compile-time options, and parameters — are subject to variability that exacerbates frictions but is also essential for achieving robust, generalizable results and fostering innovation. I will first review the literature, providing evidence of how the complex variability interactions across these layers affect qualitative and quantitative software properties, thereby complicating the reproduction and replication of scientific studies in various fields.
I will then present some software engineering and AI techniques that can support the strategic exploration of variability spaces. These include the use of abstractions and models (e.g., feature models), sampling strategies (e.g., uniform, random), cost-effective measurements (e.g., incremental build of software configurations), and dimensionality reduction methods (e.g., transfer learning, feature selection, software debloating).
I will finally argue that deep variability is both the problem and solution of frictionless reproducibility, calling the software science community to develop new methods and tools to manage variability and foster reproducibility in software systems.
Exposé invité Journées Nationales du GDR GPL 2024
Richard's aventures in two entangled wonderlandsRichard Gill
Since the loophole-free Bell experiments of 2020 and the Nobel prizes in physics of 2022, critics of Bell's work have retreated to the fortress of super-determinism. Now, super-determinism is a derogatory word - it just means "determinism". Palmer, Hance and Hossenfelder argue that quantum mechanics and determinism are not incompatible, using a sophisticated mathematical construction based on a subtle thinning of allowed states and measurements in quantum mechanics, such that what is left appears to make Bell's argument fail, without altering the empirical predictions of quantum mechanics. I think however that it is a smoke screen, and the slogan "lost in math" comes to my mind. I will discuss some other recent disproofs of Bell's theorem using the language of causality based on causal graphs. Causal thinking is also central to law and justice. I will mention surprising connections to my work on serial killer nurse cases, in particular the Dutch case of Lucia de Berk and the current UK case of Lucy Letby.
3. INTRODUCTION
ICP (Inductively Coupled Plasma) Spectroscopy is an analytical method used to
detect and measure elements to analyze chemical samples. The process is based on
the ionization of a sample by an extremely hot plasma, usually made from argon
gas. The instrumentation itself consists of optics, mechanics, electronics, and signal
processing.
four main methods of optical spectroscopy are absorption, emission, luminescence,
and scattering.
3
There also are several other spectrometric methods for observing optical quantities,
including reflection, refraction, diffraction, polarization, refractive index change,
and acoustic waves.
4. 4
ICP
TYPES
unique to other forms of inorganic mass spectrometry is its
ability to sample the analyte continuously, without
interruption.
Instrument detection limits are at or below the single part
per trillion (ppt) level for much of the periodic table
Analytical working range is nine orders of magnitude
Productivity is unsurpassed by any other technique
Isotopic analysis can be achieved readily
ICP-MS
6. PRINCIPLE
6
The ICP-MS instrument measures most of the elements in the periodic table.
An inductively coupled plasma is a plasma that is energized (ionized)
by inductively heating the gas with an electromagnetic coil, and contains a
sufficient concentration of ions and electrons to make the gas electrically
conductive.
In its simplest form, ICP-MS takes a pre-prepared liquid containing the analyte,
pumps it through a nebulizer to create an aerosol which is introduced into an argon
gas plasma. The high temperature of the plasma (~5500-6500 K) is sufficient to
atomize and ionize almost all elements, including those with the highest ionization
potentials.
ICP-MS can be used to measure the
individual isotopes of each element;
this capability brings value to
laboratory studies.
interested in one specific isotope of
an element or in the ratio between
two isotopes of an element.
By using a semi-quantitative software package, an unknown sample can be
analyzed for 80 elements in three minutes, providing semi-quantitative data
that is typically within ±30% of the quantitative values.
7. 7
ICP-MS ICP-AES
Plasma Horizontal: generates cations
Vertical: excites atoms, which
emit photons
Ion detection Mass-to-charge ratio Wavelength of emitted light
Detection limit 1-10 ppt 1-10 ppb
Working range 8 orders of magnitude 6 orders of magnitude
Throughput 20-30 elements per minute 10-40 elements per minute
Isotope detection Yes No
Cost ~$150,000 ~$50,000
Multi-element detection Yes Yes
Spectral interferences Predictable, less than 300
Much greater in number and
more complicated to correct
Routine accessories
Electro thermal vaporization, laser
ablation, high-performance liquid
chromatography, etc.
Rare
In ICP-AES, the ions are excited by vertical plasma, emitting photons that are separated on
the basis of their emission wavelengths. As implied by the name, ICP-MS separates the
ions, generated by horizontal plasma, on the basis of their mass-to-charge ratios (m/z).
COMPARISON of ICP-MS and ICP-AES
8. light source
sampling interface,
peristaltic pump leading to a nebulizer,
spray chamber,
plasma torch,
detector,
ion-focusing system,
mass-separation device,
vacuum chamber, maintained by turbo molecular
pumps
INSTRUMENTATION
8
9. LIGHT SOURCE
9
ICP
torch
An inductively coupled plasma (ICP) or transformer coupled
plasma (TCP) is a type of plasma source in which the energy is
supplied by electric currents which are produced by electromagnetic
induction, that is, by time-varying magnetic fields.
Plasma electron temperatures can range between ~6,000 K and
~10,000 K (~6 eV – ~100 eV)
The plasma used in an ICP-MS is made by
partially ionizing argon gas (Ar → Ar+ +
e−). The energy required for this reaction is
obtained by pulsing an alternating electric
current in load coil that surrounds the
plasma torch with a flow of argon gas.
The plasmas used in spectro-chemical analysis are essentially
electrically neutral, with each positive charge on an ion balanced by a
free electron.
In these plasmas the positive ions are almost all singly charged and
there are few negative ions, so there are nearly equal numbers of ions
and electrons in each unit volume of plasma.
10. 10
NEBULIZER
The basic operation works as follows: a liquid sample is pumped into the nebulizer
to convert the sample into a spray.
An internal standard, such as germanium, is pumped into a mixer along with the
sample prior to nebulization to compensate for matrix effects.
ICP-MS system operates with an
Nebulizer, in which a high
velocity Argon gas stream meets a
liquid stream causing film wise
breakup of the solution into a fine
aerosol. The aerosol particle size
should ideally be sub-10µm with a
narrow particle size distribution to
achieve efficient atomization and
ionization.
For coupling to mass spectrometry, the ions from the plasma are extracted through a
series of cones into a mass spectrometer, usually a quadrupole. The ions are
separated on the basis of their mass-to-charge ratio and a detector receives an ion
signal proportional to the concentration.
11. 11
The plasma dries the aerosol, dissociates the molecules, and then removes an
electron from the components, thereby forming singly-charged ions, which are
directed into a mass filtering device known as the mass spectrometer.
The carrier gas is sent through the central channel and into the very hot plasma.
The sample is then exposed to radio frequency which converts the gas into a plasma.
The high temperature of the plasma is sufficient to cause a very large portion of the
sample to form ions. This fraction of ionization can approach 100% for some
elements (e.g. sodium), but this is dependent on the ionization potential.
Mass Spectrometer– acts as a mass filter to sort ions by their mass-to-charge ratio
(m/z).
MASS SPECTROMETER
GASES used
ICP-MS uses an argon (Ar) plasma – the ICP – to convert the sample into ions that
are then measured using a mass spectrometer – the MS. ICP-MS.
Helium (He) is often used as an aerosol carrier gas in 193 nm ArF excimer laser
ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis
because it increases the signal intensity compared with that obtained using argon
(Ar).
12. DETECTOR
12
Detector – counts individual ions exiting the quadrupole.
The mass separation device separates these ions based on their mass-to-charge
ratio.
An ion detector then converts these ions into an electrical signal, which is
multiplied and read by computer software.
Photons that reach the detector can be erroneously counted as ions, which increases
background and degrades detection limits.
VACUUM CHAMBER
vacuum chamber, maintained by turbo molecular pumps.
An ICP torch operates at room pressure and at an elevated temperature, and a mass
spectrometer, operates under a vacuum and at room temperature.
13. APPLICATIONS
13
Qualitative and Semi quantitative Applications: One of the strengths of ICP-MS is
its ability to provide a survey scan, that allows for the identification of the elements
present in a sample. Analysis of a single sample that contains known concentrations of
these elements is suitable for providing a rough estimate of their concentration in the
sample.
Quantitative Analysis: For a more accurate and precise quantitative analysis, one can
prepare multiple external standards and prepare a calibration curve. Linearly across
approximately six orders of magnitude with detection limits of less than 1 ppb.
Including an internal standard in the external standards can help reduce matrix effects.
The ideal internal standard will not produce isobaric ions and its primary ionization
potential should be similar to that for the analyte; when working with several analyte, it
may be necessary to choose a different internal standard for each analyte.
Medical
Pharmaceutical
Materials and metallurgy
Nuclear
Nanotechnology
Food and beverage (including wine and drinking
water analysis and pesticide screening)
Natural resource
exploration
Petrochemicals
Environmental
(including soil
analysis)
Regulatory