SlideShare a Scribd company logo
1 of 17
Download to read offline
Group D
Analytical and Instrumental
Inorganic Chemistry
By: Dr. Damodar Koirala
1
Atomic Emission Spectroscopy (AES)
Plasma Source
Basic principle
The electron of an atom moves from higher energy level to lower energy
level they emit extra amount of energy in the form of light which is consist of
photon
-Small part of sample is vaporized
-Free atom gain energy from plasma source
-It results in transition from lower to higher
energy state
-On returning back a photon of radiation is
emitted.
The plasma based AES in principle, is similar to the flame photometry; the
only difference being that flame is replaced by much more energetic
atomization-excitation processes using plasma.
Components of Plasma-AES
Source
• Plasma atomizer/source to create a population of excited
analyte atoms
• A wavelength selector to isolate the specific wavelength
• A light-sensitive detector to measure the light accurately
• Electronic devices to measure response of the detector
• Because of the relatively low temperatures (~2000-2500 C) in a flame-
based system, not all of the atoms or elements present in the sample are
excited, particularly if they exist in a polyatomic compound.
• The limitation of flame as an atomization-excitation source led to the
development of high temperature sources for atomic emission spectrometry.
• In plasma-based systems the temperature is considerably hotter (~6000 to
10 000 K) that results in more effective excitation of atoms (generally
greater then 90%) of approximately 60 elements including some nonmetals.
• This intense heat prevents polyatomic species from forming, thus
increasing the detection limits for many elements.
• While plasma-based systems eliminate many problems, they are not free of
interferences
Why plasma ?
Plasma is an electrical conducting gaseous mixture that contains the
significant concentration of cations and electrons. In emission
spectroscopy , the frequently used plasma source is Argon plasma. Here,
the Argon ions and electrons are the principle conducting species.
Plasma has 2 characteristics:
I- can conduct electricity
II- affected by magnetic fields
Plasma Source
Types: Depending on the power sources employed
(1) the inductively coupled plasma (ICP): radio frequency
(2) the direct current plasma (DCP): direct current
(3) the microwave induced plasma (MIP): microwave frequency
Why argon is preferred ?
i) Lesser chemical interference since it is inert and does not form stable
compound
ii) Argon ions once formed are capable to maintain high temp up to
10,000K in which atomization of any type is possible.
iii)It is optically transparent in the UV-visible region of the spectrum hence
does not offer spectral interference
iv) It has low thermal conductivity, so the heat is retained within the
plasma fireball sustaining stable operation at moderate power inputs.
v) As the abundance of argon is reasonable (1% in air), it is economical as
compared to other noble gases.
vi)As the first ionization energy of argon is quite high (15.75) eV, it has the
capacity to atomize, ionize and excite most of the elements
Instrumentation:
• A typical ICP source is called torch which consists of three concentric
quartz tubes through which current of Argon gas flows.
• The diameter of the largest tube is about 2.5 cm.
• The top of this tube is surrounded by a water-cooled induction coil
which is power by radio –frequency(RF) generator
Inductively Coupled Plasma(ICP) source
In a plasma torch the sample is injected with argon gas through central tube
(generally 0.3 to 1.5 lit/ min).
A typical arrangement of nebulizer is shown below:
Sample Introduction
Inductively Coupled Plasma(ICP) source
1) Pneumatic Nebulizer
2) Pneumatic
Aerosole Generator
3) Ultrasonic Nebulizer
Solid sample can be introduced via electrothermal vaporization.
Gaseous samples can can be mixed with argon and send to torch.
Fig: Typical ICP source (Torch).
Emission
region
• Meaning that the plasma is generated due
to differences in the magnetic field and
currents.
• Ionization of the flowing argon is initiated
by a spark from a Tesla coil.
• The resulting ions and electrons, then
interact with the fluctuating magnetic field
produced by the induction coil. This
interaction causes the ions and electrons
within the coil to flow in the closed annular
paths.
Inductively Coupled Plasma(ICP) source
Inductively Coupled Plasma(ICP) structure
Brilliant white core: Ar continuum and lines
Flame-like tail : up to 2 cm
Transparent region : Analytical region
(Cone shaped 5000-6000 K)
Advantages of ICP-AES
• Rapid and simultaneous multi-element analysis. 40-50 elements in 5 min
• Lack of chemical interferences.
• High temperature of the excitation source : 5000 to 10000K.
• Low sample requirements.
• Absence of self absorption, the cause of non-linear calibration plots in FES.
• Validity of calibration curves over 4 to 6 orders of magnitude.
• Low detection limits: 1 to 100 ng/g or µg/l (part per billion).
• Good accuracy and precision: relative standard deviation of about 1 %
• Applicability to elements that are difficult to be determined by AAS: B, C,
Ce, La, Nb, Pr, S, P, Ti, Ta, V and Zr can also be measured.
ICP systems greatly reduce the number of interferences over those created
in flame-based systems.
Spectral, physical and chemical interference may present, however
spectral are most prominent.
Chemical interferences are common in FAAS and FAES but are less
common or practically nonexistent in ICP-AES due to the relatively high
temperature of the plasma, long residence time in the plasma, and inert
atmosphere of the Ar plasma.
Interference in ICP-AES
These interferences are associated with the processes of sample
nebulisation and transport.
The chemical interferences include molecular compound formation,
ionisation effects, and solute vaporisation effects.
If present, these can be minimised by carefully controlling the operating
conditions such as incident power, observation position, matrix matching,
etc.
Interference in ICP-AES
Spectral Interference (common):
Involves the overlap of the spectral lines:
eg: Cu emission at 515.323 nm and Ar at 515.139 nm.
*more than one analytical line of a single element can be used.
Another common spectral interference involves the formation of undesired
species (e.g., ions, metal oxides). e.g., Fe along with Fe+, Fe+2, etc.)
Similarly, the formation of metal oxides or metal carbides, are also potential
source of interference and need to be evaluated on an individual basis. 

Background emission and stray light can interfere and usually be compensated
for by subtracting the background emission
Direct current plasma (DCP)
vs ICP
Direct current plasma (DCP)
The plasma jet is formed by bringing the cathode into momentary contact with the
anodes.
Ionization of the argon occurs and a current develops (~14 A) that generates additional
ions to sustain the current indefinitely.
The temperature at the arc core is more than 8000 K and at the viewing region about
5000 K.
The sample is aspirated into the area between the two arms of the Y, where it is
atomized, excited, and detected.
• DCP is an order of magnitude less sensitive than ICP
• Similar reproducibilities
• DCP requires less Argon gas
• Auxiliary power less expensive in DCP
• Graphite electrode must be replaced every couple of hrs
vs ICP
Application of Plasma Sources
Agricultural: Analysis of agricultural products
Health sciences : Determination of Al in blood, Cu in brain tissue, Se in
liver, Na in breast milk.
Geological sciences: Presence of lanthanides and other elements in rock
Forensic Sciences : Crime scene soil analysis.
Metallurgy : Analysis of trace elements in stainless steel.
Environmental science: Waste water analysis, determination of pollutant
Industry : Presence of metals like Cu, Fe, Ni, and Si in gasoline at tracer
concentration.
Plasma sources are rich in characteristic emission lines, which makes them
useful for both qualitative and quantitative elemental analysis.
Comparison of Spectroscopic Techniques
Performance Criteria Flame AA
Electrothermal
Sampling
Flame
AES
DCP ICP
Matrix interfernces high high high low low
Spectral Interferences low low low moderate high
Precision & Accuracy
Better for
unskilled
Worse for
unskilled
Costs $$ $$$ $ $$$ $$$$
Instrumentation low low low moderate
high
Maintenance
low low low moderate high
Sample Preparation moderate moderate
low
moderate moderate
Operator skill lower higher higher higher higher

More Related Content

What's hot

AUGER & ESCA Spectroscopy( Mass Spectroscopy )
AUGER & ESCA Spectroscopy( Mass Spectroscopy )AUGER & ESCA Spectroscopy( Mass Spectroscopy )
AUGER & ESCA Spectroscopy( Mass Spectroscopy )Sachin Kale
 
Atomic absorption spectroscopy
Atomic absorption spectroscopy Atomic absorption spectroscopy
Atomic absorption spectroscopy AyeshaRasty
 
Coulometric method of analysis
Coulometric method of analysisCoulometric method of analysis
Coulometric method of analysisSiham Abdallaha
 
Auger electron spectroscopy
Auger electron spectroscopyAuger electron spectroscopy
Auger electron spectroscopyGulfam Hussain
 
Polarography
PolarographyPolarography
Polarographysai sree
 
Thermal analysis - TGA & DTA
Thermal analysis - TGA & DTAThermal analysis - TGA & DTA
Thermal analysis - TGA & DTANaresh Babu
 
Cyclic Voltammetry Application
Cyclic Voltammetry  Application Cyclic Voltammetry  Application
Cyclic Voltammetry Application Halavath Ramesh
 
Polarography and Voltammetry
Polarography and VoltammetryPolarography and Voltammetry
Polarography and VoltammetrySudha durairaj
 
High Frequency Titrations
High Frequency TitrationsHigh Frequency Titrations
High Frequency TitrationsSagarika Rao
 
ATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPYATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPYnadeem akhter
 
Photoelectron spectroscopy
Photoelectron spectroscopyPhotoelectron spectroscopy
Photoelectron spectroscopytesfayehh
 
X ray Photoelectron Spectroscopy (XPS)
X ray Photoelectron Spectroscopy (XPS)X ray Photoelectron Spectroscopy (XPS)
X ray Photoelectron Spectroscopy (XPS)Nano Encryption
 

What's hot (20)

AUGER & ESCA Spectroscopy( Mass Spectroscopy )
AUGER & ESCA Spectroscopy( Mass Spectroscopy )AUGER & ESCA Spectroscopy( Mass Spectroscopy )
AUGER & ESCA Spectroscopy( Mass Spectroscopy )
 
ELECTROGRAVIMETRY
ELECTROGRAVIMETRYELECTROGRAVIMETRY
ELECTROGRAVIMETRY
 
Voltammetry vipul
Voltammetry vipulVoltammetry vipul
Voltammetry vipul
 
Atomic absorption spectroscopy
Atomic absorption spectroscopy Atomic absorption spectroscopy
Atomic absorption spectroscopy
 
Coulometric method of analysis
Coulometric method of analysisCoulometric method of analysis
Coulometric method of analysis
 
Amperometric Titrations
Amperometric TitrationsAmperometric Titrations
Amperometric Titrations
 
AMPEROMETRY
AMPEROMETRYAMPEROMETRY
AMPEROMETRY
 
Auger electron spectroscopy
Auger electron spectroscopyAuger electron spectroscopy
Auger electron spectroscopy
 
Polarography
PolarographyPolarography
Polarography
 
Thermal analysis - TGA & DTA
Thermal analysis - TGA & DTAThermal analysis - TGA & DTA
Thermal analysis - TGA & DTA
 
Cyclic Voltammetry Application
Cyclic Voltammetry  Application Cyclic Voltammetry  Application
Cyclic Voltammetry Application
 
Amperometry
AmperometryAmperometry
Amperometry
 
Polarography and Voltammetry
Polarography and VoltammetryPolarography and Voltammetry
Polarography and Voltammetry
 
Lect. 5 polarographic maxima and its interpretation
Lect. 5 polarographic maxima and its interpretationLect. 5 polarographic maxima and its interpretation
Lect. 5 polarographic maxima and its interpretation
 
High Frequency Titrations
High Frequency TitrationsHigh Frequency Titrations
High Frequency Titrations
 
Atomic spectroscopy
Atomic spectroscopyAtomic spectroscopy
Atomic spectroscopy
 
ATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPYATOMIC ABSORPTION SPECTROSCOPY
ATOMIC ABSORPTION SPECTROSCOPY
 
Photoelectron spectroscopy
Photoelectron spectroscopyPhotoelectron spectroscopy
Photoelectron spectroscopy
 
Absorption Spectroscopy
Absorption SpectroscopyAbsorption Spectroscopy
Absorption Spectroscopy
 
X ray Photoelectron Spectroscopy (XPS)
X ray Photoelectron Spectroscopy (XPS)X ray Photoelectron Spectroscopy (XPS)
X ray Photoelectron Spectroscopy (XPS)
 

Similar to AES Plasma

ICP AES overview-Nipa 25.01.2023.pptx
ICP AES overview-Nipa 25.01.2023.pptxICP AES overview-Nipa 25.01.2023.pptx
ICP AES overview-Nipa 25.01.2023.pptxDr. Nipa Mendapara
 
Mridu-ICP-MS.pptx
Mridu-ICP-MS.pptxMridu-ICP-MS.pptx
Mridu-ICP-MS.pptxSweetuCutie
 
Atomic absorption spectrophotometry
Atomic absorption spectrophotometryAtomic absorption spectrophotometry
Atomic absorption spectrophotometrySurabhi Pal
 
Harsh atomic absorption spectroscopy.ppt
Harsh atomic absorption spectroscopy.pptHarsh atomic absorption spectroscopy.ppt
Harsh atomic absorption spectroscopy.pptHarshJugani
 
Principles of Inductively coupled plasma spectrometry.pptx
Principles of Inductively coupled plasma spectrometry.pptxPrinciples of Inductively coupled plasma spectrometry.pptx
Principles of Inductively coupled plasma spectrometry.pptxShweta Pandey
 
CHM260 - AAS (ii)
CHM260 - AAS (ii)CHM260 - AAS (ii)
CHM260 - AAS (ii)Alia Najiha
 
Atomic Absorption Spectroscopy (AAS)
Atomic Absorption Spectroscopy (AAS)Atomic Absorption Spectroscopy (AAS)
Atomic Absorption Spectroscopy (AAS)Sajjad Ullah
 
Горбунов Н.А.
Горбунов Н.А.Горбунов Н.А.
Горбунов Н.А.ThinTech
 
Atomic emision spectroscopy
Atomic emision spectroscopy Atomic emision spectroscopy
Atomic emision spectroscopy Nabeel Ahmad
 
Lecture 3. Atomic-absorption spectrophotometry.pptx
Lecture 3. Atomic-absorption spectrophotometry.pptxLecture 3. Atomic-absorption spectrophotometry.pptx
Lecture 3. Atomic-absorption spectrophotometry.pptxlyazzatfreedom
 
Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...
Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...
Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...Alexander Decker
 
Analytical Chemistry
Analytical ChemistryAnalytical Chemistry
Analytical ChemistrySidra Javed
 
Mass spectroscopy
Mass spectroscopyMass spectroscopy
Mass spectroscopylavanya0238
 
Three papers about HiPIMS and mass spectrometry
Three papers about HiPIMS and mass spectrometryThree papers about HiPIMS and mass spectrometry
Three papers about HiPIMS and mass spectrometryJavier García Molleja
 
Inductively Coupled Plasma-Optical Emission Spectroscopy
Inductively Coupled Plasma-Optical Emission Spectroscopy Inductively Coupled Plasma-Optical Emission Spectroscopy
Inductively Coupled Plasma-Optical Emission Spectroscopy karthi keyan
 

Similar to AES Plasma (20)

ICP AES overview-Nipa 25.01.2023.pptx
ICP AES overview-Nipa 25.01.2023.pptxICP AES overview-Nipa 25.01.2023.pptx
ICP AES overview-Nipa 25.01.2023.pptx
 
ICP-AES.pptx
ICP-AES.pptxICP-AES.pptx
ICP-AES.pptx
 
Atomic emission spectroscopy
Atomic emission spectroscopyAtomic emission spectroscopy
Atomic emission spectroscopy
 
Mridu-ICP-MS.pptx
Mridu-ICP-MS.pptxMridu-ICP-MS.pptx
Mridu-ICP-MS.pptx
 
Atomic absorption spectrophotometry
Atomic absorption spectrophotometryAtomic absorption spectrophotometry
Atomic absorption spectrophotometry
 
ICP Presentation
ICP PresentationICP Presentation
ICP Presentation
 
Harsh atomic absorption spectroscopy.ppt
Harsh atomic absorption spectroscopy.pptHarsh atomic absorption spectroscopy.ppt
Harsh atomic absorption spectroscopy.ppt
 
Principles of Inductively coupled plasma spectrometry.pptx
Principles of Inductively coupled plasma spectrometry.pptxPrinciples of Inductively coupled plasma spectrometry.pptx
Principles of Inductively coupled plasma spectrometry.pptx
 
CHM260 - AAS (ii)
CHM260 - AAS (ii)CHM260 - AAS (ii)
CHM260 - AAS (ii)
 
Atomic Absorption Spectroscopy (AAS)
Atomic Absorption Spectroscopy (AAS)Atomic Absorption Spectroscopy (AAS)
Atomic Absorption Spectroscopy (AAS)
 
ICPMS (1).pptx
ICPMS (1).pptxICPMS (1).pptx
ICPMS (1).pptx
 
Горбунов Н.А.
Горбунов Н.А.Горбунов Н.А.
Горбунов Н.А.
 
Atomic emision spectroscopy
Atomic emision spectroscopy Atomic emision spectroscopy
Atomic emision spectroscopy
 
Lecture 3. Atomic-absorption spectrophotometry.pptx
Lecture 3. Atomic-absorption spectrophotometry.pptxLecture 3. Atomic-absorption spectrophotometry.pptx
Lecture 3. Atomic-absorption spectrophotometry.pptx
 
Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...
Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...
Performance analysis of a monopole antenna with fluorescent tubes at 4.9 g hz...
 
Analytical Chemistry
Analytical ChemistryAnalytical Chemistry
Analytical Chemistry
 
Presentation2
Presentation2Presentation2
Presentation2
 
Mass spectroscopy
Mass spectroscopyMass spectroscopy
Mass spectroscopy
 
Three papers about HiPIMS and mass spectrometry
Three papers about HiPIMS and mass spectrometryThree papers about HiPIMS and mass spectrometry
Three papers about HiPIMS and mass spectrometry
 
Inductively Coupled Plasma-Optical Emission Spectroscopy
Inductively Coupled Plasma-Optical Emission Spectroscopy Inductively Coupled Plasma-Optical Emission Spectroscopy
Inductively Coupled Plasma-Optical Emission Spectroscopy
 

More from Damodar Koirala

More from Damodar Koirala (17)

Polymer chemistry
Polymer chemistryPolymer chemistry
Polymer chemistry
 
Atomic absorption spectroscopy
Atomic absorption spectroscopyAtomic absorption spectroscopy
Atomic absorption spectroscopy
 
Chemistry in service to mankind
Chemistry in service to mankindChemistry in service to mankind
Chemistry in service to mankind
 
Heavy metals
Heavy metalsHeavy metals
Heavy metals
 
Molecular geometry and chemical bonding
Molecular geometry and chemical bondingMolecular geometry and chemical bonding
Molecular geometry and chemical bonding
 
Volumetric analysis part 2
Volumetric analysis part 2Volumetric analysis part 2
Volumetric analysis part 2
 
Volumetric analysis part 1
Volumetric analysis part 1Volumetric analysis part 1
Volumetric analysis part 1
 
Ionic equilibrium part 2
Ionic equilibrium part 2Ionic equilibrium part 2
Ionic equilibrium part 2
 
Ionic equilibrium part 1
Ionic equilibrium part 1Ionic equilibrium part 1
Ionic equilibrium part 1
 
Review of Atomic Spectroscopy / Analytical Instrumentation
Review of Atomic Spectroscopy / Analytical InstrumentationReview of Atomic Spectroscopy / Analytical Instrumentation
Review of Atomic Spectroscopy / Analytical Instrumentation
 
Flame Photometry
Flame PhotometryFlame Photometry
Flame Photometry
 
Stoichiometry
StoichiometryStoichiometry
Stoichiometry
 
Alkali metal
Alkali metalAlkali metal
Alkali metal
 
Alkaline earth metal
Alkaline earth metalAlkaline earth metal
Alkaline earth metal
 
Hydrocarbon
HydrocarbonHydrocarbon
Hydrocarbon
 
Basic organic chemistry 2
Basic organic chemistry 2Basic organic chemistry 2
Basic organic chemistry 2
 
Basic organic chemistry
Basic organic chemistryBasic organic chemistry
Basic organic chemistry
 

Recently uploaded

Spermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatidSpermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatidSarthak Sekhar Mondal
 
Analytical Profile of Coleus Forskohlii | Forskolin .pdf
Analytical Profile of Coleus Forskohlii | Forskolin .pdfAnalytical Profile of Coleus Forskohlii | Forskolin .pdf
Analytical Profile of Coleus Forskohlii | Forskolin .pdfSwapnil Therkar
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRDelhi Call girls
 
Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )aarthirajkumar25
 
SOLUBLE PATTERN RECOGNITION RECEPTORS.pptx
SOLUBLE PATTERN RECOGNITION RECEPTORS.pptxSOLUBLE PATTERN RECOGNITION RECEPTORS.pptx
SOLUBLE PATTERN RECOGNITION RECEPTORS.pptxkessiyaTpeter
 
CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service 🪡
CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service  🪡CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service  🪡
CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service 🪡anilsa9823
 
Disentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOSTDisentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOSTSérgio Sacani
 
Nanoparticles synthesis and characterization​ ​
Nanoparticles synthesis and characterization​  ​Nanoparticles synthesis and characterization​  ​
Nanoparticles synthesis and characterization​ ​kaibalyasahoo82800
 
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |aasikanpl
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...Sérgio Sacani
 
Animal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxAnimal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxUmerFayaz5
 
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptxanandsmhk
 
Analytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptxAnalytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptxSwapnil Therkar
 
PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...
PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...
PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...Sérgio Sacani
 
Bentham & Hooker's Classification. along with the merits and demerits of the ...
Bentham & Hooker's Classification. along with the merits and demerits of the ...Bentham & Hooker's Classification. along with the merits and demerits of the ...
Bentham & Hooker's Classification. along with the merits and demerits of the ...Nistarini College, Purulia (W.B) India
 
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisRaman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisDiwakar Mishra
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Sérgio Sacani
 
Types of different blotting techniques.pptx
Types of different blotting techniques.pptxTypes of different blotting techniques.pptx
Types of different blotting techniques.pptxkhadijarafiq2012
 

Recently uploaded (20)

Spermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatidSpermiogenesis or Spermateleosis or metamorphosis of spermatid
Spermiogenesis or Spermateleosis or metamorphosis of spermatid
 
Analytical Profile of Coleus Forskohlii | Forskolin .pdf
Analytical Profile of Coleus Forskohlii | Forskolin .pdfAnalytical Profile of Coleus Forskohlii | Forskolin .pdf
Analytical Profile of Coleus Forskohlii | Forskolin .pdf
 
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCRStunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
Stunning ➥8448380779▻ Call Girls In Panchshil Enclave Delhi NCR
 
Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )Recombination DNA Technology (Nucleic Acid Hybridization )
Recombination DNA Technology (Nucleic Acid Hybridization )
 
SOLUBLE PATTERN RECOGNITION RECEPTORS.pptx
SOLUBLE PATTERN RECOGNITION RECEPTORS.pptxSOLUBLE PATTERN RECOGNITION RECEPTORS.pptx
SOLUBLE PATTERN RECOGNITION RECEPTORS.pptx
 
CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service 🪡
CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service  🪡CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service  🪡
CALL ON ➥8923113531 🔝Call Girls Kesar Bagh Lucknow best Night Fun service 🪡
 
Disentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOSTDisentangling the origin of chemical differences using GHOST
Disentangling the origin of chemical differences using GHOST
 
Nanoparticles synthesis and characterization​ ​
Nanoparticles synthesis and characterization​  ​Nanoparticles synthesis and characterization​  ​
Nanoparticles synthesis and characterization​ ​
 
Engler and Prantl system of classification in plant taxonomy
Engler and Prantl system of classification in plant taxonomyEngler and Prantl system of classification in plant taxonomy
Engler and Prantl system of classification in plant taxonomy
 
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
Call Us ≽ 9953322196 ≼ Call Girls In Mukherjee Nagar(Delhi) |
 
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
All-domain Anomaly Resolution Office U.S. Department of Defense (U) Case: “Eg...
 
Animal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptxAnimal Communication- Auditory and Visual.pptx
Animal Communication- Auditory and Visual.pptx
 
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptxUnlocking  the Potential: Deep dive into ocean of Ceramic Magnets.pptx
Unlocking the Potential: Deep dive into ocean of Ceramic Magnets.pptx
 
Analytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptxAnalytical Profile of Coleus Forskohlii | Forskolin .pptx
Analytical Profile of Coleus Forskohlii | Forskolin .pptx
 
9953056974 Young Call Girls In Mahavir enclave Indian Quality Escort service
9953056974 Young Call Girls In Mahavir enclave Indian Quality Escort service9953056974 Young Call Girls In Mahavir enclave Indian Quality Escort service
9953056974 Young Call Girls In Mahavir enclave Indian Quality Escort service
 
PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...
PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...
PossibleEoarcheanRecordsoftheGeomagneticFieldPreservedintheIsuaSupracrustalBe...
 
Bentham & Hooker's Classification. along with the merits and demerits of the ...
Bentham & Hooker's Classification. along with the merits and demerits of the ...Bentham & Hooker's Classification. along with the merits and demerits of the ...
Bentham & Hooker's Classification. along with the merits and demerits of the ...
 
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral AnalysisRaman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
Raman spectroscopy.pptx M Pharm, M Sc, Advanced Spectral Analysis
 
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
Discovery of an Accretion Streamer and a Slow Wide-angle Outflow around FUOri...
 
Types of different blotting techniques.pptx
Types of different blotting techniques.pptxTypes of different blotting techniques.pptx
Types of different blotting techniques.pptx
 

AES Plasma

  • 1. Group D Analytical and Instrumental Inorganic Chemistry By: Dr. Damodar Koirala 1 Atomic Emission Spectroscopy (AES) Plasma Source
  • 2. Basic principle The electron of an atom moves from higher energy level to lower energy level they emit extra amount of energy in the form of light which is consist of photon -Small part of sample is vaporized -Free atom gain energy from plasma source -It results in transition from lower to higher energy state -On returning back a photon of radiation is emitted. The plasma based AES in principle, is similar to the flame photometry; the only difference being that flame is replaced by much more energetic atomization-excitation processes using plasma.
  • 3. Components of Plasma-AES Source • Plasma atomizer/source to create a population of excited analyte atoms • A wavelength selector to isolate the specific wavelength • A light-sensitive detector to measure the light accurately • Electronic devices to measure response of the detector
  • 4. • Because of the relatively low temperatures (~2000-2500 C) in a flame- based system, not all of the atoms or elements present in the sample are excited, particularly if they exist in a polyatomic compound. • The limitation of flame as an atomization-excitation source led to the development of high temperature sources for atomic emission spectrometry. • In plasma-based systems the temperature is considerably hotter (~6000 to 10 000 K) that results in more effective excitation of atoms (generally greater then 90%) of approximately 60 elements including some nonmetals. • This intense heat prevents polyatomic species from forming, thus increasing the detection limits for many elements. • While plasma-based systems eliminate many problems, they are not free of interferences Why plasma ?
  • 5. Plasma is an electrical conducting gaseous mixture that contains the significant concentration of cations and electrons. In emission spectroscopy , the frequently used plasma source is Argon plasma. Here, the Argon ions and electrons are the principle conducting species. Plasma has 2 characteristics: I- can conduct electricity II- affected by magnetic fields Plasma Source Types: Depending on the power sources employed (1) the inductively coupled plasma (ICP): radio frequency (2) the direct current plasma (DCP): direct current (3) the microwave induced plasma (MIP): microwave frequency
  • 6. Why argon is preferred ? i) Lesser chemical interference since it is inert and does not form stable compound ii) Argon ions once formed are capable to maintain high temp up to 10,000K in which atomization of any type is possible. iii)It is optically transparent in the UV-visible region of the spectrum hence does not offer spectral interference iv) It has low thermal conductivity, so the heat is retained within the plasma fireball sustaining stable operation at moderate power inputs. v) As the abundance of argon is reasonable (1% in air), it is economical as compared to other noble gases. vi)As the first ionization energy of argon is quite high (15.75) eV, it has the capacity to atomize, ionize and excite most of the elements
  • 7. Instrumentation: • A typical ICP source is called torch which consists of three concentric quartz tubes through which current of Argon gas flows. • The diameter of the largest tube is about 2.5 cm. • The top of this tube is surrounded by a water-cooled induction coil which is power by radio –frequency(RF) generator Inductively Coupled Plasma(ICP) source
  • 8. In a plasma torch the sample is injected with argon gas through central tube (generally 0.3 to 1.5 lit/ min). A typical arrangement of nebulizer is shown below: Sample Introduction Inductively Coupled Plasma(ICP) source 1) Pneumatic Nebulizer 2) Pneumatic Aerosole Generator 3) Ultrasonic Nebulizer Solid sample can be introduced via electrothermal vaporization. Gaseous samples can can be mixed with argon and send to torch.
  • 9. Fig: Typical ICP source (Torch). Emission region • Meaning that the plasma is generated due to differences in the magnetic field and currents. • Ionization of the flowing argon is initiated by a spark from a Tesla coil. • The resulting ions and electrons, then interact with the fluctuating magnetic field produced by the induction coil. This interaction causes the ions and electrons within the coil to flow in the closed annular paths. Inductively Coupled Plasma(ICP) source
  • 10. Inductively Coupled Plasma(ICP) structure Brilliant white core: Ar continuum and lines Flame-like tail : up to 2 cm Transparent region : Analytical region (Cone shaped 5000-6000 K)
  • 11. Advantages of ICP-AES • Rapid and simultaneous multi-element analysis. 40-50 elements in 5 min • Lack of chemical interferences. • High temperature of the excitation source : 5000 to 10000K. • Low sample requirements. • Absence of self absorption, the cause of non-linear calibration plots in FES. • Validity of calibration curves over 4 to 6 orders of magnitude. • Low detection limits: 1 to 100 ng/g or µg/l (part per billion). • Good accuracy and precision: relative standard deviation of about 1 % • Applicability to elements that are difficult to be determined by AAS: B, C, Ce, La, Nb, Pr, S, P, Ti, Ta, V and Zr can also be measured.
  • 12. ICP systems greatly reduce the number of interferences over those created in flame-based systems. Spectral, physical and chemical interference may present, however spectral are most prominent. Chemical interferences are common in FAAS and FAES but are less common or practically nonexistent in ICP-AES due to the relatively high temperature of the plasma, long residence time in the plasma, and inert atmosphere of the Ar plasma. Interference in ICP-AES These interferences are associated with the processes of sample nebulisation and transport. The chemical interferences include molecular compound formation, ionisation effects, and solute vaporisation effects. If present, these can be minimised by carefully controlling the operating conditions such as incident power, observation position, matrix matching, etc.
  • 13. Interference in ICP-AES Spectral Interference (common): Involves the overlap of the spectral lines: eg: Cu emission at 515.323 nm and Ar at 515.139 nm. *more than one analytical line of a single element can be used. Another common spectral interference involves the formation of undesired species (e.g., ions, metal oxides). e.g., Fe along with Fe+, Fe+2, etc.) Similarly, the formation of metal oxides or metal carbides, are also potential source of interference and need to be evaluated on an individual basis. 
 Background emission and stray light can interfere and usually be compensated for by subtracting the background emission
  • 14. Direct current plasma (DCP) vs ICP
  • 15. Direct current plasma (DCP) The plasma jet is formed by bringing the cathode into momentary contact with the anodes. Ionization of the argon occurs and a current develops (~14 A) that generates additional ions to sustain the current indefinitely. The temperature at the arc core is more than 8000 K and at the viewing region about 5000 K. The sample is aspirated into the area between the two arms of the Y, where it is atomized, excited, and detected. • DCP is an order of magnitude less sensitive than ICP • Similar reproducibilities • DCP requires less Argon gas • Auxiliary power less expensive in DCP • Graphite electrode must be replaced every couple of hrs vs ICP
  • 16. Application of Plasma Sources Agricultural: Analysis of agricultural products Health sciences : Determination of Al in blood, Cu in brain tissue, Se in liver, Na in breast milk. Geological sciences: Presence of lanthanides and other elements in rock Forensic Sciences : Crime scene soil analysis. Metallurgy : Analysis of trace elements in stainless steel. Environmental science: Waste water analysis, determination of pollutant Industry : Presence of metals like Cu, Fe, Ni, and Si in gasoline at tracer concentration. Plasma sources are rich in characteristic emission lines, which makes them useful for both qualitative and quantitative elemental analysis.
  • 17. Comparison of Spectroscopic Techniques Performance Criteria Flame AA Electrothermal Sampling Flame AES DCP ICP Matrix interfernces high high high low low Spectral Interferences low low low moderate high Precision & Accuracy Better for unskilled Worse for unskilled Costs $$ $$$ $ $$$ $$$$ Instrumentation low low low moderate high Maintenance low low low moderate high Sample Preparation moderate moderate low moderate moderate Operator skill lower higher higher higher higher