FLAME ATOMIC ABSORPTION
SPECTROPHOTOMETER
MODEL NO.- ACM--FAAS-2687
R
FLAME ATOMIC ABSORPTION
SPECTROPHOTOMETER
R
Ÿ Reasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less
automation to provide an economic model for users
Ÿ Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the
instrument
Ÿ Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy
and fast analysis
FEATURES
Main Specification
Light Source
System
Optical System
Wavelength Range
Wavelength Accuracy
Resolution
Baseline Stability
Background Correction
Lamp Turret
Lamp Current Adjustment
Lamp Power Supply Mode
190-900nm
±0.5nm
Two spectral lines of Mn at 279.5nm and 279.8nm can be
separated with the spectral bandwidth of 0.2nm and
valley-peak energy ratio less than 30%.
SPECIFICATIONS
0.005A/30min
Monochomator
Grating
Focal length
Blazed Wavelength
Single beam, Czerny-Turner design grating
monochromator
The D2 lamp background correction capability at 1A is
better than 30 times
2 Lamps are powerd simultaneously (one preheated)
0~20mA
400Hz Square Wave Pulse;
1800 l/mm
277mm
250nm
R
Spectral Bandwidth
Adjustment
Burner
Spray Chamber
Position Adjustment
Gas Line Protection
Detector
Display Mode
Electronic and micro-
computer system
Read Mode
Scale Expansion
Data Processing Mode
Fuel gas leakage alarm/min
R928 Photomultiplier with high sensitivity and wide
spectral range.
0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change
Manual adjustment for wavelength and slit
10cm single slot all-titanium burner
Corrosion resistant all-plastic spray chamber
Manual adjusting mechanism for vertical, horizontal
positions and the rotation angle of the burner/min
Automatic adjustment of light source power.
Light energy and negative high-voltage auto-balance
LEC display of energy and measurement values,
concentration direct reading.
Transient, time average, peak height, peak area, integral
time is selectable in the range of 0.1~19.9s.
0.1~99
Automatic calculation of mean, standard deviation and
relative standard deviation.
Flame Atomizer
Detection and Data
Processing System
R
Measurement Mode
Result Printing
Instrument Self-Check
Air-Acetylene
Hydride vapor generator
can be connected for
hydride analysis
Main unit
Characteristic
Concentration and
Detection Limit
Function Expansion
Dimensions and Weight
Reporting number is in the range of 1~99 Automatic
cureve fitting with 3~7 standards; Sensitivity auto-
correction
Check current status of each function key
Cu: Characteristic concentration=0.025mg/L, Detection
limit=0.006mg/L;
102×49×54cm, unpacked 80kg
Measurement data, working curve, signal profile and
analytical conditions can all be printed out
R
TECHNOCRACY PVT. LTD.
www.acmasindia.com | www.cleanroom-equipments.com | www.measuring-meters.com
An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485
WHO: GMP Products | GLP Compliant Products
SALES OFFICE (HONG KONG)
SHOWROOM
SALES OFFICE (RUSSIA)
Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East,
Sheung Wan, Hong Kong (PRC)
Tel.: 0086-13929598046 0086- 18922303099
E-mail.: hk@acmasindia.com
J-284 Sector 1 Bawana Industrial Estate, Bawana,
Delhi, INDIA-110039
Tel.: 0091-0-9312219738 (M) +91- 9717741167
E-mail.: info@acmasindia.com
Inmed Trade Street Ozerkovsky Embankment,
Unit No 50, Straine- 1, Off- 502, Moscow, Russia
E-mail.: info@acmasindia.com
Tel.: 0049- 79592345 | Email: russia@acmasindia.com
SALES OFFICE (INDIA)
th
Office no. 506 & 507, 5 Floor, Plot no.- C-9,
Pearls Best Height-II, Netaji Subhash Place,
Pitam Pura, Delhi- 110034
Land Line No.: +91 - 11- 47619688,
Fax: +91-11-47619788
E-mail.: info@acmasindia.com

Flame atomic absorption spectrophotometer

  • 1.
  • 2.
    FLAME ATOMIC ABSORPTION SPECTROPHOTOMETER R ŸReasonable design, adopting the same key parts as in high end instruments, ensures basic functions but less automation to provide an economic model for users Ÿ Built-in microprocessor with necessary auto-control and data processing functions achieve high reliability of the instrument Ÿ Eye-catching digital display, multi-function data processing ability and fast function-key direct input realize easy and fast analysis FEATURES
  • 3.
    Main Specification Light Source System OpticalSystem Wavelength Range Wavelength Accuracy Resolution Baseline Stability Background Correction Lamp Turret Lamp Current Adjustment Lamp Power Supply Mode 190-900nm ±0.5nm Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. SPECIFICATIONS 0.005A/30min Monochomator Grating Focal length Blazed Wavelength Single beam, Czerny-Turner design grating monochromator The D2 lamp background correction capability at 1A is better than 30 times 2 Lamps are powerd simultaneously (one preheated) 0~20mA 400Hz Square Wave Pulse; 1800 l/mm 277mm 250nm R
  • 4.
    Spectral Bandwidth Adjustment Burner Spray Chamber PositionAdjustment Gas Line Protection Detector Display Mode Electronic and micro- computer system Read Mode Scale Expansion Data Processing Mode Fuel gas leakage alarm/min R928 Photomultiplier with high sensitivity and wide spectral range. 0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change Manual adjustment for wavelength and slit 10cm single slot all-titanium burner Corrosion resistant all-plastic spray chamber Manual adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner/min Automatic adjustment of light source power. Light energy and negative high-voltage auto-balance LEC display of energy and measurement values, concentration direct reading. Transient, time average, peak height, peak area, integral time is selectable in the range of 0.1~19.9s. 0.1~99 Automatic calculation of mean, standard deviation and relative standard deviation. Flame Atomizer Detection and Data Processing System R
  • 5.
    Measurement Mode Result Printing InstrumentSelf-Check Air-Acetylene Hydride vapor generator can be connected for hydride analysis Main unit Characteristic Concentration and Detection Limit Function Expansion Dimensions and Weight Reporting number is in the range of 1~99 Automatic cureve fitting with 3~7 standards; Sensitivity auto- correction Check current status of each function key Cu: Characteristic concentration=0.025mg/L, Detection limit=0.006mg/L; 102×49×54cm, unpacked 80kg Measurement data, working curve, signal profile and analytical conditions can all be printed out R
  • 6.
    TECHNOCRACY PVT. LTD. www.acmasindia.com| www.cleanroom-equipments.com | www.measuring-meters.com An ISO 9001 : 2208 | ISO 14001 : 2008 | ISO 13485 WHO: GMP Products | GLP Compliant Products SALES OFFICE (HONG KONG) SHOWROOM SALES OFFICE (RUSSIA) Unit D 28 11/F Wing Tat Comm,Bidg 97, Bonham Strand East, Sheung Wan, Hong Kong (PRC) Tel.: 0086-13929598046 0086- 18922303099 E-mail.: hk@acmasindia.com J-284 Sector 1 Bawana Industrial Estate, Bawana, Delhi, INDIA-110039 Tel.: 0091-0-9312219738 (M) +91- 9717741167 E-mail.: info@acmasindia.com Inmed Trade Street Ozerkovsky Embankment, Unit No 50, Straine- 1, Off- 502, Moscow, Russia E-mail.: info@acmasindia.com Tel.: 0049- 79592345 | Email: russia@acmasindia.com SALES OFFICE (INDIA) th Office no. 506 & 507, 5 Floor, Plot no.- C-9, Pearls Best Height-II, Netaji Subhash Place, Pitam Pura, Delhi- 110034 Land Line No.: +91 - 11- 47619688, Fax: +91-11-47619788 E-mail.: info@acmasindia.com