1) Distillation is a method used to separate components of a liquid solution based on differences in how the components distribute between the vapor and liquid phases when heated to their boiling points.
2) Raoult's law describes vapor-liquid equilibrium for ideal solutions, relating the partial pressure of a component in vapor phase to its mole fraction in the liquid phase. Boiling point diagrams can be constructed using vapor pressure data.
3) Equilibrium or flash distillation involves heating a liquid mixture to partially vaporize it in a single stage, separating the vapor and liquid which approach equilibrium compositions.
COURSE LINK:
https://www.chemicalengineeringguy.com/courses/gas-absorption-stripping/
Introduction:
Gas Absorption is one of the very first Mass Transfer Unit Operations studied in early process engineering. It is very important in several Separation Processes, as it is used extensively in the Chemical industry.
Understanding the concept behind Gas-Gas and Gas-Liquid mass transfer interaction will allow you to understand and model Absorbers, Strippers, Scrubbers, Washers, Bubblers, etc…
We will cover:
- REVIEW: Of Mass Transfer Basics required
- GAS-LIQUID interaction in the molecular level, the two-film theory
- ABSORPTION Theory
- Application of Absorption in the Industry
- Counter-current & Co-current Operation
- Several equipment to carry Gas-Liquid Operations
- Bubble, Spray, Packed and Tray Column equipments
- Solvent Selection
- Design & Operation of Packed Towers
- Pressure drop due to packings
- Solvent Selection
- Design & Operation of Tray Columns
- Single Component Absorption
- Single Component Stripping/Desorption
- Diluted and Concentrated Absorption
- Basics: Multicomponent Absorption
- Software Simulation for Absorption/Stripping Operations (ASPEN PLUS/HYSYS)
----
Please show the love! LIKE, SHARE and SUBSCRIBE!
More likes, sharings, suscribers: MORE VIDEOS!
-----
CONTACT ME
Chemical.Engineering.Guy@Gmail.com
www.ChemicalEngineeringGuy.com
http://facebook.com/Chemical.Engineering.Guy
You speak spanish? Visit my spanish channel -www.youtube.com/ChemEngIQA
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project (https://www.spire2030.eu/impress).
Section: Distillation
Subject: 0.2 Introduction to distillation.
Types of Distillation & column internalsBharat Kumar
More:- https://chemicalengineeringworld.com
Distillation is a method of separating the components of a solution which depends upon distribution of the substances between a gas and liquid phase, applied to cases where all components are present in both phases.
* What is distillation ?
* Types of Distillation
* Batch Distillation
* Azeotropic Distillation
* Flooding
* Priming
* Coning
* Weeping
* Dumping
* Packed Column
* Tray column
* Reflux Ratio
* Relative volatility
* Distillation column
Distillation is a method of separating mixtures based on differences in volatility (volatility is the tendency of a substance to vaporize. Volatility is directly related to a substance's vapor pressure.) of components in a boiling liquid mixture. Distillation is a unit operation, or a physical separation process, and not a chemical reaction
COURSE LINK:
https://www.chemicalengineeringguy.com/courses/gas-absorption-stripping/
Introduction:
Gas Absorption is one of the very first Mass Transfer Unit Operations studied in early process engineering. It is very important in several Separation Processes, as it is used extensively in the Chemical industry.
Understanding the concept behind Gas-Gas and Gas-Liquid mass transfer interaction will allow you to understand and model Absorbers, Strippers, Scrubbers, Washers, Bubblers, etc…
We will cover:
- REVIEW: Of Mass Transfer Basics required
- GAS-LIQUID interaction in the molecular level, the two-film theory
- ABSORPTION Theory
- Application of Absorption in the Industry
- Counter-current & Co-current Operation
- Several equipment to carry Gas-Liquid Operations
- Bubble, Spray, Packed and Tray Column equipments
- Solvent Selection
- Design & Operation of Packed Towers
- Pressure drop due to packings
- Solvent Selection
- Design & Operation of Tray Columns
- Single Component Absorption
- Single Component Stripping/Desorption
- Diluted and Concentrated Absorption
- Basics: Multicomponent Absorption
- Software Simulation for Absorption/Stripping Operations (ASPEN PLUS/HYSYS)
----
Please show the love! LIKE, SHARE and SUBSCRIBE!
More likes, sharings, suscribers: MORE VIDEOS!
-----
CONTACT ME
Chemical.Engineering.Guy@Gmail.com
www.ChemicalEngineeringGuy.com
http://facebook.com/Chemical.Engineering.Guy
You speak spanish? Visit my spanish channel -www.youtube.com/ChemEngIQA
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project (https://www.spire2030.eu/impress).
Section: Distillation
Subject: 0.2 Introduction to distillation.
Types of Distillation & column internalsBharat Kumar
More:- https://chemicalengineeringworld.com
Distillation is a method of separating the components of a solution which depends upon distribution of the substances between a gas and liquid phase, applied to cases where all components are present in both phases.
* What is distillation ?
* Types of Distillation
* Batch Distillation
* Azeotropic Distillation
* Flooding
* Priming
* Coning
* Weeping
* Dumping
* Packed Column
* Tray column
* Reflux Ratio
* Relative volatility
* Distillation column
Distillation is a method of separating mixtures based on differences in volatility (volatility is the tendency of a substance to vaporize. Volatility is directly related to a substance's vapor pressure.) of components in a boiling liquid mixture. Distillation is a unit operation, or a physical separation process, and not a chemical reaction
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project (https://www.spire2030.eu/impress).
Section: Distillation
Subject: 1.2 Flash distillation.
An overview of distillation column design concepts and major design considerations. Explains distillation column design concepts, what you would provide to a professional distillation column designer, and what you can expect back from a distillation system design firm. To speak with an engineer about your distillation column project, call EPIC at 314-207-4250.
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project (https://www.spire2030.eu/impress).
Subject: 2.4 Plate efficiencies.
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project.
Section: Distillation
Subject: 1.1 Vapor Liquid Equilibrium
Distillation is the basic and oldest chemical separation process used in the chemical industries and petroleum refining.
Let's recognize the difference between Packed and Plate columns in industry and the comparison of their usage!
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project (https://www.spire2030.eu/impress).
Section: Distillation
Subject: 1.2 Flash distillation.
An overview of distillation column design concepts and major design considerations. Explains distillation column design concepts, what you would provide to a professional distillation column designer, and what you can expect back from a distillation system design firm. To speak with an engineer about your distillation column project, call EPIC at 314-207-4250.
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project (https://www.spire2030.eu/impress).
Subject: 2.4 Plate efficiencies.
Slides for the eLearning course Separation and purification processes in biorefineries (https://open-learn.xamk.fi) in IMPRESS project.
Section: Distillation
Subject: 1.1 Vapor Liquid Equilibrium
Distillation is the basic and oldest chemical separation process used in the chemical industries and petroleum refining.
Let's recognize the difference between Packed and Plate columns in industry and the comparison of their usage!
Vapour Liquid Equilibirium using digramatic representationShubham Budhawant
It contains information about Vapour liquid Equilibrium and graphical presentation to explain the conditions. It contains all the information about it.
1.Dew Point with non-condensable components
2.Flash with liquid vapor products
3.Condenser and Flash drum for ammonia synthesis
4.Azeotrope
Ideal Solutions vs. Azeotropes
Types of Azeotropes
• Number of Constituents:
• Heterogeneous or Homogeneous:
• Positive or Negative:
5.Enthalpy change of mixing
6.Solutropes
16 concentration distributions in solids and laminar flowAnees43
This lecture was delivered by Hafiz Anees Rehman at Quaid-Awam-University, Nawab Shah Pakistan for Transport Phenomenon course. It includes: Diffusion, Stagnant, Gas, Liquid, Film,Law, Mass, Transfer, Molar, Concentrations
PHYSICAL CHEMISTRY - Relative Molecular Masses in Solutionsshahzadebaujiti
PHYSICAL CHEMISTRY - Relative Molecular Masses in Solutions
SOLUTIONS
What is a solution homogeneous?
A solution is a uniform mixture of two or more substances.
The substance which are mixed to form solution are also termed as components
Example of solution
We have to learn ERP because in future if we get to develop an ERP module or work on it, then we must understand the business needs that it is trying to fulfill.
When we clearly understand the functioning of a department in an enterprise, then we will be able to develop a module to automate it.
We also need to understand the interaction between modules.
PRINCIPAL OF COOLING TOWER
TYPES OF COOLING TOWER
DIFFERENT TERMS USED IN COOLING TOWER SPECIFICATION
AIR PROPERTIES AND
SIZING OF COOLING TOWER HEIGHT
TYPICAL SPECIFICATION FORMAT / DATASHEET
INTRODUCTION AND BASICS OF REFRIGERATION
REFRIGERANT SELECTION CRITERIA (ASHRAE STANDARD)
AUXILLARY EQUIPMENTS IN REFRIGERATION CYCLE
LOAD CALCULATION (PEAK LOAD AND AVERAGE LOAD)
PRILIMINARY PROCESS DESIGN
EQUIPMENT DESIGN AND SPECIFICATION
SPECIFICATION OF COMPLETE REFRIGERATION PACKAGE
P & ID TYPICAL REFRIGERATION PLANT
START-UP AND SHUT-DOWN
TROUBLE SHOOTING AND CHECKLIST
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Courier management system project report.pdfKamal Acharya
It is now-a-days very important for the people to send or receive articles like imported furniture, electronic items, gifts, business goods and the like. People depend vastly on different transport systems which mostly use the manual way of receiving and delivering the articles. There is no way to track the articles till they are received and there is no way to let the customer know what happened in transit, once he booked some articles. In such a situation, we need a system which completely computerizes the cargo activities including time to time tracking of the articles sent. This need is fulfilled by Courier Management System software which is online software for the cargo management people that enables them to receive the goods from a source and send them to a required destination and track their status from time to time.
COLLEGE BUS MANAGEMENT SYSTEM PROJECT REPORT.pdfKamal Acharya
The College Bus Management system is completely developed by Visual Basic .NET Version. The application is connect with most secured database language MS SQL Server. The application is develop by using best combination of front-end and back-end languages. The application is totally design like flat user interface. This flat user interface is more attractive user interface in 2017. The application is gives more important to the system functionality. The application is to manage the student’s details, driver’s details, bus details, bus route details, bus fees details and more. The application has only one unit for admin. The admin can manage the entire application. The admin can login into the application by using username and password of the admin. The application is develop for big and small colleges. It is more user friendly for non-computer person. Even they can easily learn how to manage the application within hours. The application is more secure by the admin. The system will give an effective output for the VB.Net and SQL Server given as input to the system. The compiled java program given as input to the system, after scanning the program will generate different reports. The application generates the report for users. The admin can view and download the report of the data. The application deliver the excel format reports. Because, excel formatted reports is very easy to understand the income and expense of the college bus. This application is mainly develop for windows operating system users. In 2017, 73% of people enterprises are using windows operating system. So the application will easily install for all the windows operating system users. The application-developed size is very low. The application consumes very low space in disk. Therefore, the user can allocate very minimum local disk space for this application.
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
Democratizing Fuzzing at Scale by Abhishek Aryaabh.arya
Presented at NUS: Fuzzing and Software Security Summer School 2024
This keynote talks about the democratization of fuzzing at scale, highlighting the collaboration between open source communities, academia, and industry to advance the field of fuzzing. It delves into the history of fuzzing, the development of scalable fuzzing platforms, and the empowerment of community-driven research. The talk will further discuss recent advancements leveraging AI/ML and offer insights into the future evolution of the fuzzing landscape.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Forklift Classes Overview by Intella PartsIntella Parts
Discover the different forklift classes and their specific applications. Learn how to choose the right forklift for your needs to ensure safety, efficiency, and compliance in your operations.
For more technical information, visit our website https://intellaparts.com
1. 1
Distillation
Introduction
Distillation is a method used to separate the components of liquid solution,
which depends upon the distribution of these various components between
a vapor and a liquid phase.
The vapor phase is created from the liquid phase by vaporization at the
boiling point.
Distillation is concerned with solution where all components are appreciably
volatile such as in ammonia-water or ethanol-water solutions, where both
components will be in the vapor phase.
2. 2
Vapor-Liquid Equilibrium Relations
Raoult’s Law
An ideal law, Rault’s law, can be defined for vapor-liquid phases in
equilibrium (only ideal solution e.g. benzene-toluene, hexane-heptane etc.
Where
pA is the partial pressure of component A in the vapor in Pa (atm)
PA is the vapor pressure of pure A in Pa (atm)
xA is the mole fraction of A in the liquid.
AAA xPp =
BA xx +=1
BA yy +=1
Composition in liquid:
Composition in vapor:
(1)
(2)
(3)
3. 3
Boiling-point diagram for system benzene (A)-toluene (B) at a total pressure
of 101.32 kPa.
Boiling-Point Diagrams and xy Plots
Dew point is the temperature at which
the saturated vapor starts to condense.
Bubble-point is the temperature at
which the liquid starts to boil.
The difference between liquid and vapor
compositions is the basis for distillation
operations.
4. 4
Boiling-point diagram for system benzene (A)-toluene (B) at a total pressure
of 101.32 kPa.
Boiling-Point Diagrams and xy Plots
If we start with a cold liquid
composition is xA1 = 0.318 (xB1
= 0.682) and heat the mixture, it
will start to boil at 98ºC.
The first vapor composition in
equilibrium is yA1 = 0.532 (yB1 =
0.468).
Continue boiling, the
composition xA will move to the
left since yA is richer in A.
5. 5
Boiling-Point Diagrams and xy Plots
Ppp BA =+
PxPxP ABAA =−+ )1(
P
xP
P
p
y AAA
A ==
The boiling point diagram can be calculated from (1) the pure vapor-
pressure data in the table below and (2) the following equations:
(4)
(5)
(6)
Where
pA, pB are the partial pressure of component A and B in the vapor in Pa (atm)
PA , PB are the vapor pressure of pure A and pure B in Pa (atm)
P is total pressure in Pa (atm)
xA is the mole fraction of A in the liquid.
6. 6
Boiling-Point Diagrams and xy Plots
The boiling point diagram can be calculated from (1) the pure vapor-
pressure data in the table below and (2) the following equations:
1
7. 7
Exmpl Use of Raoult’s Law for Boiling-Point Diagram
Calculate the vapor and liquid compositions in equilibrium at 95ºC
(368.2K) for benzene-toluene using the vapor pressure from the
table 1 at 101.32 kPa.
Solution: At 95ºC from Table 1 for benzene, PA = 155.7 kPa and PB = 63.3
kPa. Substituting into Eq.(5) and solving,
155.7(xA) + 63.3(1-xA) = 101.32 kPa (760 mmHg)
Hence, xA= 0.411 and xB= 1 – xA = 1 - 0.411 = 0.589. Substituting into eqn.
(6),
PxPxP ABAA =−+ )1(
632.0
32.101
)411.0(7.155
====
P
xP
P
p
y AAA
A
8. 8
The boiling point diagram can be calculated from the pure vapor-pressure
data in the table below and the following equations:
1
9. 9
A common method of plotting the equilibrium data is shown in Fig. 2 where
yA is plotted versus xA for the benzene-toluene system. The 45º line is
given to show that yA is richer in component A than is xA.
Fig. 2 Equilibrium diagram for system benzene(A) – toluene(B) at 101.32
kPa (1atm).
10. 10
Vapor-Liquid Equilibrium Relations
Boiling-Point Diagrams and xy Plots
Maximum-boiling azeotropeMinimum-boiling azeotropeIdeal boiling point diagram
An azeotrope is a mixture of two or more liquids in such a ratio that its
composition cannot be changed by simple distillation.
This occurs because, when an azeotrope is boiled, the resulting vapor has
the same ratio of constituents as the original mixture.
12. 12
Single-Stage Equilibrium Contact for Vapor-Liquid System
V1 V2
L0 L1
MVLVL =+=+ 1120Total mass balance:
AMAAAA MxyVxLyVxL =+=+ 11112200Mass A balance:
Where
V1, V2 is a vapor
L0, L1is a liquid
A single equilibrium stage is
- the two different phases are brought into intimate contact with each other.
- The mixing time is long enough and the components are essentially at
equilibrium in the two phases after separation.
In case of constant molal overflow : V1 = V2 and L0 = L1
13. 13
Exmpl Equilibrium Contact of Vapor-Liquid Mixture
A vapor at the dew point and 101.32 kPa containing a mole fraction
of 0.40 benzene (A) and 0.60 toluene (B) and 100 kg mol total is
contacted with 110 kg mol of a liquid at the boiling point containing a
mole fraction of 0.30 benzene and 0.70 toluene. The two streams are
contacted in a single stage, and the outlet streams leave in
equilibrium with each other. Assume constant molal overflow.
Calculate the amounts and compositions of the exit streams.
Solution: The given values are V2 = 100 kg mol, yA2 = 0.40, L0=110 kg
mol , and xA0 = 0.30.
V1 V2
L0 L1
For constant molal overflow,
V2 = V1 and L0 = L1.
14. Material balance on component A,
To solve equation above, the equilibrium relation between yA1 and xA1 in
figure below must be used.
First, we assume that xA1 = 0.20 and substitute into equation above to
solve for yA1.
AMAAAA MxyVxLyVxL =+=+ 11112200
1100)2.0(110)40.0(100)30.0(110 Ay+=+
11 100110)40.0(100)30.0(110 AA yx +=+
15. Assuming that xA1 = 0.20 and solving yA1 = 0.51.
Next, assuming that xA1=0.40 and solving, yA1 = 0.29.
Next, assuming that xA1=0.40 and solving, yA1 = 0.29.
(These point are plotted on the graph.)
At the intersection of this line with the equilibrium curve,
yA1 = 0.455 and xA1 = 0.25.
17. 17
Relative Volatility of Vapor-Liquid Systems
)1)(1(
/
/
/
AA
AA
BB
AA
AB
xy
xy
xy
xy
−−
==α
AAB
AAB
A
x
x
y
)1(1 −+
=
α
α
P
xP
y AA
A =
B
A
AB
P
P
=α
P
xP
y BB
B =
Relative volatility
It is a measure of the differences in volatility between 2 components, and hence their boiling
points. It indicates how easy or difficult a particular separation will be.
Where αAB is the relative volatility of A with respect to B in the binary system.
when αAB is above 1.0, a separation is possible.
Raoult’s law:
)( ABα
18. 18
Exmpl Using data from table 1 calculate the relative volatility for the
benzene-toluene system at 85ºC (358.2K) and 105ºC (378.2K)
Solution: At 85ºC, substituting into equation below for a system following
Rault’s law,
Similarly at 105ºC,
The variation in α is about 7%. Answer
54.2
0.46
9.116
===
B
A
AB
P
P
α
38.2
0.86
2.204
==α
19. 19
Equilibrium or Flash Distillation
Distillation has two main methods in practice.
Introduction to distillation methods
1. Production of vapor by boiling the liquid mixture to be separated in a
single stage and recovering and condensing the vapors. No liquid
is allowed to return to the single-stage still to contact the
rising vapors.
2. Returning of a portion of the condensate to the still. The vapors
rise through a series of stages or trays, and part of the condensate
flows downward through the series of stages or trays counter
currently to the vapors (“fractional distillation, distillation with reflux,
or rectification”).
There are 3 important types of distillation that occur in a single stage or
still: Equilibrium or flash distillation, Simple batch or differential
distillation and simple steam distillation
20. 20
Equilibrium or Flash Distillation
heater
Separator
xA
yA
Flash distillation is a single stage separation technique.
1. A liquid mixture is pumped through a heater to raise the temperature
and enthalpy of the mixture.
2. It then flows through a valve and the pressure is reduced, causing
the liquid to partially vaporize.
3. Once the mixture enters a big enough volume (the “flash drum”), the liquid and
vapor separate.
4. Because the vapor and liquid are in such close contact up until the “flash” occurs,
the product liquid and vapor phases approach equilibrium.
21. 21
Equilibrium or Flash Distillation
heater
Separator
Total mass balance:
Component A balance:
where
F, V and L are flow rate of feed, vapor and liquid phases.
xF, yA and xA are mole fraction of component A in feed, vapor and liquid.
AAF xfyfx )1( −+=
Where
f = V/F = molal fraction of the feed that is vaporized and withdrawn continuously as vapor.
1-f = one as liquid
Material balance for more volatile component :
xA
yA
AAF x
F
V
F
F
y
F
V
x )()( −+=
AAF LxyVFx +=
LVF +=
22. 22
Exmpl A mixture of 50% mole normal heptane and 50% normal
octane at 30ºC is continuously flash distilled at 1 standard
atmosphere so that 60 mol% of the feed is vaporized. What will be
the composition of the vapor and liquid products?
xA 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
yA 0.247 0.453 0.607 0.717 0.796 0.853 0.898 0.935 0.968
Solution: Given: xF = 0.5, f = 0.6
Find: xA, yA
Basis: F = 100 mols
Applying the mass balance yields:
Since ,
LVF +=
60)100(6.0 === fFV
4060100 =−=−= VFL
FVf /=
23. 23
Material balance for more volatile component,
Substituting value of f =0.6 and xF =0.5 we get,
Assuming that xA = 0.5 and solving yA = 0.5.
Next, assuming that xA=0 and solving, yA = 0.83.
(These point are plotted on the graph.)
At the intersection of this line with the equilibrium curve,
yA = 0.58 and xA = 0.39.
AAF xfyfx )1( −+=
AAF x
F
V
F
F
y
F
V
x )()( −+=
AA xy )6.01(6.05.0 −+=
AA xy 4.06.05.0 +=
25. 25
Simple Batch or Differential Distillation
The pot is filled with liquid mixture and heated.
Vapor flows upwards though the column and
condenses at the top.
Part of the liquid is returned to the column as
reflux, and the remainder withdrawn as
distillate.
Nothing is added or withdrawn from the still
until the run is completed.
26. 26
Simple Batch or Differential Distillation
The total moles of component A left in the still
nA will be
nA = xn
where
n is the moles of liquid left in the still at a given
time
y and x is the vapor and liquid compositions
If a small amount of liquid dn is vaporized, the change in the moles of component A is ydn, or
dnA. Differentiating equation a gives
ydnxdnndx
xdnndxxnddnA
=+
+== )(
xy
dx
n
dn
−
=
27. 27
B
A
AB
B
A
x
x
y
y
α=
dx/(y-x) can be integrated graphically or numerically using tabulated equilibrium data
or an equilibrium curve.
For ideal mixture:
∫∫ =
−
=
1
0 0
1
1
0
ln
x
x
n
n
n
n
xy
dx
n
dn
xy
dx
n
dn
−
=
B
B
AB
A
A
B
A
AB
B
A
B
A
n
dn
n
dn
n
n
dn
dn
dndn
dndn
α
α
=
==
AB
A
A
B
B
n
n
n
n
α/1
00
=
B
B
AB
A
A
n
n
n
n
00
lnln α=
Simple Batch or Differential Distillation
Integrating
28. 28
Exmpl A batch of crude pentane contains 15 mole percent n-
butane and 85 percent n-pentane. If a simple batch distillation at
atmospheric pressure is used to remove 90 percent of butane,
how much pentane will be removed? What will be the
composition of the remaining liquid?
Solution: The final liquid is nearly pure pentane, and its boiling point is
36ºC. The vapor pressure of butane at this temperature is 3.4 atm, giving a
relative volatility of 3.4. For the initial conditions, the boiling point is about
27ºC, and the relative volatility is 3.6. Therefore, an average value of 3.5 is
used for αAB.
Basis: 1 mol feed
(batane) (pentane)
From equation:
nB = total mole of B left in still, nA = total mole A left in still.
n0B = total initial mole of B in still, n0A = total initial mole A lin still.
15.0=OAn 015.0=An 85.0=OBn
AB
A
A
B
B
n
n
n
n
α/1
00
=
30. 30
Simple Steam Distillation
Note that by steam distillation, as long as water is present, the high-
boiling component B vaporizes at a temperature well below its normal
boiling point without using a vacuum. The A and B are usually
condensed in condenser and the resulting two immiscible liquid
phases separated.
Disadvantage: large amounts of heat must be used to simultaneously
evaporate the water with high-boiling compound.
31. 31
Simple Steam Distillation
When the sum of the separate vapor pressures equals the total pressure,
the mixture boils and
Where
is vapor pressure of pure water A
is vapor pressure of pure B
Then the vapor composition is
The ratio moles of B distilled to moles of A distilled is
PPP BA =+
BP
P
P
y A
A =
AP
P
P
y B
B =
A
B
A
B
P
P
n
n
=
32. 32
Temperature PA(water)
(mm Hg)
PB(ethylaniline)
(mm Hg)K ºC
353.8 80.6 48.5 1.33
369.2 96.0 87.7 2.67
372.3 99.15 98.3 3.04
386.4 113.2 163.3 5.33
Exmpl A mixture contains 100 kg of H2O and 100 kg of ethylene
(mol wt = 121.1 kg/kg mol), which is immiscible with water. A very
slight amount of nonvolatile impurity is dissolved in the organic.
To purify the ethyaniline it is steam-distilled by bubbling saturated
steam into the mixture at a total pressure of 101.32 kPa (1 atm).
Determine the boiling point of the mixture and the composition of
the vapor. The vapor pressure of each of the pure compounds is
as follows (T1):
33. 33
Solution:
PPP BA =+
Temperature PA
(water)
(kPa)
PB
(ethylaniline)
(kPa)
P=PA+PB
(kPa)K ºC
353.8 80.6 48.5 1.33 49.83
369.2 96.0 87.7 2.67 90.37
372.3 99.15 98.3 3.04 101.34
386.4 113.2 163.3 5.33 169.23
The boiling temperature = 99.15ºC since total pressure in this temperature
is equal to atmospheric pressure.
The vapor composition are:
97.0
32.101
3.98
===
kPa
kPa
P
P
y A
A 03.0
32.101
04.3
===
P
P
y B
B
34. 34
Distillation with Reflux and McCabe-Thiele
method
Introduction to Distillation with Reflux
Rectification (fractionation) or stage distillation with reflux is
a series of flash-vaporization stages are arranged in a series which the vapor and liquid
products from each stage flow counter currently to each other.
V2
L1
V1
V2
L0 L1
V3
L2
Vn Vn+1
Ln-1 Ln
The liquid in a stage is conducted or flows to the stage below and the vapor from a stage
flow upward to the stage above.
nnnn LVLV +=+ −+ 11
nnnnnnnn xLyVxLyV +=+ −−++ 1111
A total material balance:
A component balance on A:
35. 35
Introduction to Distillation with Reflux
1. Feed enters the column somewhere in
the middle of the column.
5. The vapor continues up to the next tray
or stage, where it is again contacted with
a downflowing liquid.
2. Feed is liquid, it flows down to a sieve
tray or stage.
4. The vapor and liquid leaving the tray
are essentially in equilibrium.
In a distillation column the stages (referred to as sieve plates or trays) in a distillation tower are
arranged vertically, as shown schematically in figure below.
3. Vapor enters the tray and bubbles
through the liquid on this tray as the
entering liquid flows across.
6. The concentration of the more volatile
component is being increased in the
vapor form each stage going upward and
decreased in the liquid from each stage
going donwards.
36. 36
Introduction to Distillation with Reflux
7. The final vapor product coming
overhead is condensed in a condenser
and a portion of the liquid product
(distillate) is removed, which contains a
high concentration of A.
9. The liquid leaving the bottom tray
enters a reboilier, where it partially
vaporized, and the remaining liquid, which
is lean in A or rich in B, is withdrawn as
liquid product.
In a distillation column the stages (referred to as sieve plates or trays) in a distillation tower are
arranged vertically, as shown schematically in figure below.
8. The remaining liquid from the
condenser is returned (refluxed) as a
liquid to the top tray.
10. The vapor from the reboiler is sent
back to the bottom stage or trays is much
greater.
37. 37
McCabe-Thiele Method of Calculation for Number of
Theoretical Stages
A mathematical – graphical method for determining the number of theoretical trays
or stages needed for a given separation of a binary mixture of A and B has been
developed by McCabe and Thiele.
The method uses material balances around certain parts of the tower, which give
operating lines and the xy equilibrium curve for the system.
Main assumption
1) Equimolar overflow through the tower between the feed inlet and the top tray and
the feed inlet and bottom tray.
2) Liquid and vapor streams enter a tray, are equilibrated, and leave.
A) Introduction and assumptions
38. 38
A total material balance:
nnnn LVLV +=+ −+ 11
A component A balance:
nnnnnnnn xLyVxLyV +=+ −−++ 1111
Where
Vn+1 is mol/h of vapor from tray n+1
Ln is mol/h liquid from tray n
yn+1 is mole fraction of A in Vn+1 and so on.
39. 39
A total material balance:
A component A balance:
Where
F is the entering feed (mol/h)
D is the distillate (mol/h)
W is the bottoms (mol/h)
WDF +=
wDF WxDxFx +=
B) Equation for enriching section
(1)
(2)
40. 40
Material balance over dashed-line section: DLV nn +=+1
A balance on component A: DDxxLyV nnnn +=++ 11 (4)
(3)
41. 41
Solving for yn+1, the enriching-section operating line is
)1/(, 11 +=+= ++ RRVLDLV nnnn
DLR n /=
11
1
+
+
+
=+
R
x
x
R
R
y D
nn
where = reflux ratio = constant.
The eqn. (1) is a straight line on a plot of vapor composition versus liquid
composition.
Since and equation becomes
11
1
++
+ +=
n
D
n
n
n
n
V
Dx
x
V
L
y
(6)
(5)
42. 42
The slope is or . It intersects the y=x line (45º diagonal
line) at . The intercept of the operating line at x = 0 is .
1/ +nn VL )1/( +RR
)1/( += Rxy DDxx =
The theoretical stages are determined by starting at xD and stepping off the first
plate to x1. Then y2 is the composition of the vapor passing the liquid x1.
In a similar manner, the other theoretical trays are stepped off down the tower in
the enriching section to the feed tray.
43. 43
C) Equation for stripping section
Material balance over dashed-line section: WLV mm −=+1
A component A balance: wWxxLyV mmmm −=++ 11 (8)
(7)
44. 44
Solving for ym+1, the enriching-section operating line is
11
1
++
+ +=
m
D
m
m
m
m
V
Dx
x
V
L
y (9)
1+= mm VL
Again, since equimolal flow is assumed, = constant and
= constant, eqn. (2) is a straight line when plotted as y versus x,
with a slope of . It intersects the y = x line at x = xw.
The intercept at x = 0 is .
Nm LL =
Nm VV =+1
1/ +−= mW VWxy
45. 45
The theoretical stages for the stripping section are determined by starting at
xW, going up to yW, and then across to the operating line, etc.
46. 46
D) Effect of feed conditions
The condition of feed stream is represented by the quantity q, which is the mole
fraction of liquid in feed.
qFLL nm +=
FqVV mn )1( −+=
Dnn DxxLyV +=
wmm WxxLyV −=
)()()( wDnmnm WxDxxLLyVV +−−=−
The enriching and striping operating-line
equations on an xy diagram can be
derived as follows:
Where the y and x values are the point of
intersection of the two operating lines.
Subtracting eqn.(3) from eqn.(4),
(12)
(13)
(14)
(10)
(11)
47. 47
D) Effect of feed conditions
Substituting eqn.(2), (10), and (11) into eqn.(14) and rearranging,
(15)
11 −
−
−
=
q
x
x
q
q
y F
λ
)(
1
FbpL TTc
q
−
+=
λ
)(
1
dFpV TTc
q
−
+=
Cold-liquid feed Superheated vapor
where
CpL, CpV = specific heats of liquid and vapor, respectively
TF = temperature of feed
Tb, Td = bubble point and dew point of feed respectively
λ = heat of vaporization
48. 48
E) Location of the feed tray in a tower and number of trays.
q = 0 (saturated vapor)
q = 1 (saturated liquid)
q > 1(subcooled liquid)
q < 0 (superheated vapor)
0 < q < 1 (mix of liquid and
vapor)
From eqn.(15), the q-line equation and is the locus of the intersection of the two
operating lines. Setting y = x in eqn(15), the intersection of the q-line equation
with the 45º line is y=x=xF, where xF is the overall composition of the feed.
In given below the figure, the q line is plotted for various feed conditions. The
slope of the q line is q/(q-1).
49. Slope = R/(R+1)
Slope = q/(1-q)
Slope = L/ V
F) Using Operating Lines and the Feed Line in McCabe-Thiele Design
50. Exmpl A continuous fractioning column is to be designed to separate
30,000 kg/h of a mixture of 40 percent benzene and 60 percent toluene
into an overhead product containing 97 percent benzene and a bottom
product containing 98 percent toluene. These percentages are by weight.
A reflux ratio of 3.5 mol to 1 mol of product is to be used. The molal
latent heats of benzene and toluene are 7,360 and 7,960 cal/g mol,
respectively. Benzene and toluene from a nearly ideal system with a
relative volatility of about 2.5. The feed has a boiling point of 95ºC at a
pressure of 1 atm.
a) Calculate the moles of overhead product and bottom product per hour.
b) Determine the number of ideal plates and the position of the feed plate
(i) if the feed is liquid and at its boiling point; (ii) if the feed is liquid and at
20ºC (specific heat 0.44 cal/g.ºC); (iii) if the feed is a mixture of two-thirds
vapor and one-third liquid.
51. Solution (a)
The average molecular weight of the feed is
The average of heat vaporization is
The feed rate F is 30,000/85.8 = 350 kg mol/h. By an overall benzene
balance, using Eq. below
440.0
92
60
78
40
78
40
=
+
=Fx 0235.0
92
98
78
2
78
2
=
+
=Bx974.0
92
3
78
97
78
97
=
+
=Dx
8.85
92
60
78
40
100
=
+
gmolcal /696,7)960,7(56.0)360,7(44.0 =+=λ
hkgmolD /4.153
0235.0974.0
0235.0440.0
350 =
−
−
=
hkgmolB /6.1964.153350 =−=
52. Solution (b) (i),
We determine the number of ideal plates and position of the feed plate.
1) Plot the equilibrium diagram, erect verticals at xD, xF, and xB.
2) Draw the feed line. Here q=1, and the feed line is vertical.
3) Plot the operating lines. The intercept of the rectifying lie on
the y axis is, xD/(R+1) = 0.974/(3.5+1) = 0.216 (eqn (6)). From the
intersection of the rectifying operating line and the feed line, the stripping
line is drawn.
4) Draw the rectangular steps between the two operating lines
and the equilibrium curve. The stripping line is at the seventh step. By
counting steps it is found that, besides the reboiler, 11 ideal plates are
needed and feed should be introduced on the seventh plate from the top.
53.
54. Solution (b) (ii),
The latent heat of vaporization of the feed λ is 7,696/85.8 = 98.7 cal/g.
The slope of the feed line is -1.37/(1-1.37) = 3.70. When steps are drawn
for this case, as shown in Fig. below, it is found that a reboiler and 10
ideal plates are needed and that the feed should be introduced on the
sixth plate.
37.1
7.89
)2095(44.0
1 =
−
+=q
11 −
−
−
=
q
x
x
q
q
y F
55.
56. Solution (b) (iii),
From the definition of q it follows that for this case q = 1/3 and the slope
of the feed line is -0.5. The solution is shown in Fig. below. It calls for a
reboiler and 12 plates, with the feed entering on the seventh plate.
57.
58. 58
Total and Minimum Reflux Ratio for McCabe-Thiele Method
A) Total Reflux
One limiting values of reflux ratio is that of total reflux, or R = ∞. Since R = Ln/D
and, by eqn.(16).
DLV nn +=+1
Then Ln is very large, as is the vapor flow Vn. This means that the slope R/(R+1)
of the enriching operating line becomes 1.0 and the operating lines of both
sections of the column coincide with the 45º diagonol line, as shown in Fig below.
Minimum number of trays can be obtained by returning all the overhead
condensed vapor V1 from the top of the tower back to the tower as reflux, i.e., total
reflux. Also, the liquid in the bottoms is reboiled.
(16)
59. 59
Minimum number of theoretical steps Nm
when a total condenser is used (α is constant).
av
w
w
D
D
m
x
x
x
x
N
αlog
1
1
log
−
−
=
( ) 2/1
1 wav ααα =For small variations in α,
where α1 is the relative volatility of the overhead vapor
αw is the relative volatility of the bottoms liquid.
60. 60
B) Minimum reflux ratio
The minimum reflux ratio (Rm) will require an infinite number of trays for the given
separation desired of xD and xW.
If R is decreased, the slope of the enriching operating line R/(R+1) is decreased,
and the intersection of this line and the stripping line with the q line moves farther
from the 45º line and closer to the equilibrium line.
xx
yx
R
R
D
D
m
m
′−
′−
=
+1
Two operating lines touch the
equilibrium line (“pinch point”) at y’
and x’ (number of steps required
becomes infinite).
The line passes through the points x’,
y’ and xD (y=xD):
61. 61
C) Operating and optimum reflux ratio
Total reflux = number of plates is a minimum, but the tower diameter is infinite.
This corresponds to an infinite cost of tower and steam and cooling water. This
is the limit in the tower operation.
Minimum reflux = number of trays is infinite, which again gives an infinite cost.
These are the two limits in operation of the tower.
Actual operating reflux ratio to use is in between these two limits. The
optimum reflux ratio to use for lowest total cost per year is between the
minimum Rm and total reflux (1.2Rm to 1.5Rm).
62. General Design Consideration
1. A tower design is normally divided into two main steps, a process
design followed by a mechanical design. The purpose of the
process design is to calculate the number of required theoretical
stages, column diameter and tower height. On the other hand, the
mechanical design focuses on the tower internals and heat
exchanger arrangements.
2. Many factors have to be considered in designing a distillation column
such as the safety and environmental requirements, column
performance, economics of the design and other parameters, which
may constrain the work.
63. The first step in distillation column design is to determine the separation
sequences, which depends on the relative volatility and concentration of
each component in the feed. King has outlined a few design rules as
follows:
1) Direct sequences that remove the components one by one in the
distillate are generally favored.
2) Sequences that result in a more equal-molar division of the feed
between distillate and bottoms products should be favored.
3) Separations where the relative volatility of two adjacent components is
close to unity should be performed in the absence of other components; ie,
reserve such a separation until the last column in the sequence.
4) Separations involving high-specified recovery fractions should be
reserved until last in the sequence.
64. Once the separation sequence is decided, engineering calculations follow
to determine the number of theoretical stages, operating parameters and
tower dimensions. In general, the steps included in distillation calculations
are summarized into the following:
1) Performing a material balance for the column
2) Determining the tower operating pressure (and/or temperature)
3) Calculating the minimum number of theoretical stages using the Fenske
equation
4) Calculating the minimum reflux rate using the Underwood equations
5) Determining the operating reflux rate and number of theoretical stages
6) Selection of column internals (tray or packings)
7) Calculating the tower diameter and height
65. Some general design rules (from Cheresources.com) that should be
considered are as follows:
1) Distillation is usually the most economical method of separating
liquids.
2) For Ideal mixtures (low pressure, medium temperature, and non-
polar), relative volatility is the ratio of vapor pressures i.e. α = P2/P1
3) Tower operating pressure is determined most often by the temperature
of the available cooling medium in the condenser or by the maximum
allowable reboiler temperature.
4) Tower Sequencing :
A. Easiest separation first – least trays and reflux
B. When neither relative volatility nor feed concentrations vary widely,
remove components one by one as overhead products.
C. When the adjacent ordered components in the feed vary widely in
relative volatility, sequence the splits in order of decreasing volatility.
D. When the concentration in the feed varies widely but the relative
volatilities do not, remove the components in the order of decreasing
concentration in the feed.
66. 5) Economically optimum reflux ratio is about 120% to 150% of the
minimum reflux ratio.
6) The economically optimum number of stages is about 200% of the
minimum value.
7) A safety factor of at least 10% above the number of stages by the
best method is advisable.
8) A safety factor of at least 25% about the reflux should be utilized for
the reflux pumps.
9) Reflux drums are almost always horizontally mounted and designed
for a 5 min holdup at half of the drum's capacity.
10) For towers that are at least 3 ft (0.9 m) in diameter, 4 ft (1.2 m)
should be added to the top for vapor release and 6 ft (1.8 m) should be
added to the bottom to account for the liquid level and reboiler return.
11) Limit tower heights to 175 ft (53 m) due to wind load and foundation
considerations.
12) The Length/Diameter ratio of a tower should be no more than 30
and preferably below 20.
67. 13) A rough estimate of reboiler duty as a function of tower diameter is
given by:
Q = 0.5 D2 for pressure distillation
Q = 0.3 D2 for atmospheric distillation
Q = 0.15 D2 for vacuum distillation
Where,
Q : Energy in Million Btu/hr
D : Tower diameter in feet.
68. The Selection of Column Internals
The selection of column internals has a big impact on the column
performance and the maintenance cost of a distillation tower.
There are several choices of column internals and the two major
categories are trays and packing. The choice of which to utilize depends
on the
1) pressure,
2) fouling potential,
3) liquid to vapor density ratio,
4) liquid loading, and
5) most importantly the life cycle cost.
Trays can be divided into many categories, such as baffle trays, dual flow
trays, conventional trays, high capacity trays, multiple down comer trays
and system limit trays. According to some rules of thumb, trays should be
selected if:
1) the compounds contain solids or foulants
2) there are many internal transitions
3) liquid loads are high
4) there is a lack of experience in the service
5) vessel wall needs periodic inspection
6) there are multiple liquid phases
69. On the other hand, packing divisions include grid packing, random
packing, conventional structured packing, and high capacity structured
packing. The rules of thumb for selecting packing are:
1) the compounds are temperature sensitive
2) pressure drop is important (vacuum service)
3) liquid loads are low
4) towers are small in diameter
5) highly corrosive service (use plastic or carbon)
6) the system is foaming
7) the ratio of tower diameter to random packing is greater than 10
70. Some design guidelines should be considered when designing a tray tower,
such as follows:
1) Tray spacing should be from 18 to 24 inches, with accessibility in mind
(Generally, for a tower diameter of 4 feet and above, the most
common tray spacing is 24 inches to allow easy access for maintenance.
However, for a tower diameter below 4 feet, a tray spacing of 18 inches
is adequate as the column wall can be reached from the man way.)
2) Peak tray efficiencies usually occur at linear vapor velocities of 2 ft/s
(0.6 m/s) at moderate pressures, or 6 ft/s (1.8 m/s) under vacuum
conditions.
3) A typical pressure drop per tray is 0.1 psi (0.007 bar)
4) Tray efficiencies for aqueous solutions are usually in the range of 60-
90% while gas absorption and stripping typically have efficiencies closer
to 10-20%
5) Sieve tray holes are 0.25 to 0.50 in. diameter with the total hole area
being about 10% of the total active tray area. Maximum efficiency is 0.5 in
and 8%.
6) Valve trays typically have 1.5 in. diameter holes each with a lifting cap.
12-14 caps/square foot of tray is a good benchmark.
7) The most common weir heights are 2 and 3 in and the weir length is
typically 75% of the tray diameter.
71. The packed tower design concepts are listed below:
1) Packed towers almost always have lower pressure drop compared to
tray towers.
2) Packing is often retrofitted into existing tray towers to increase capacity
or separation.
3) For gas flow rates of 500 ft3/min (14.2 m3/min), use 1 in (2.5 cm)
packing, for gas flows of 2000 ft3/min (56.6 m3/min) or more, use 2 in
(5 cm) packing.
4) Ratio of tower diameter to packing diameter should usually be at least
15
5) Due to the possibility of deformation, plastic packing should be limited to
an unsupported depth of 10-15 ft (3-4 m) while metal packing can
withstand 20-25 ft (6-7.6 m).
6) Liquid distributor should be placed every 5-10 tower diameters (along t
he length) for pall rings and every 20 ft (6.5 m) for other types of
random packing.
7) For redistribution, there should be 8-12 streams per sq. foot of tower
area for towers larger than three feet in diameter. They should be even
more numerous in smaller towers.
8) Packed columns should operate near 70% flooding.
72. 9) Height Equivalent to Theoretical Stage (HETS) for vapor-liquid
contacting is 1.3- 1.8 ft (0.4-0.56 m) for 1 in pall rings and 2.5-3.0 ft
(0.76-0.90 m) for 2 in pall rings.
10) Design pressure drops should be as follows:
Table 1: Pressure drop in difference services