STANDARD
SOLUTIONS
LIFT
4
Μicroprocesor system for lift control
MAIN FEATURES/1
• Up to 40 stops, each stop determinated as A or B side.
• Up to 8 lifts in multiplex work.
• CAN communication between modules.
• Small dimensions.
• Central procesor unit (CPU) width 72 mm.
• Control panel width 120 mm for roomless lift.
• Landing modules with integrated arrows and dot matrix display width 42 mm suitable for new instalation and
modernization, fixed on landing plate with can / power connector for next stop without additional box in shaft.
• Landing modules for landing calls connection and different displays with different protocols (for example
TFT,LCD,...)
• LCD module for monitoring, adjustment and transfer parameters in LC100-C, adjust VVVF, load mesurement
device, connectable on any module in system (control panel, module on the top of car, displays, any landing
modules).
• One travelling cable (18 + 2x2x0.5) with connectors on both sides.
• All equipments in control panel, on cabine, in shaft, car operating panel, landing operating panels are plugable
with connectors PLUG & PLAY system.
• Teleservis through internet from any point in the world with monitoring, adjusting and analyzing all I/O, calls,
parameters, statistic, errors and warnings.
MAIN FEATURES / 2
• Software in all modules for all application is same. Differences in applications have to select only by parameters
in CPU and by address on landing modules.
• Multiplex system without any necessary additional module.
• All inputs have galvanic isolation, and they are equipt by LED diode.
• All inputs / outputs on all modules are programable with user defined function and polarity. All input and
output are predefined for all aplication.
• All landing modules are also displays or interface for displays.
• Programabile marking for each stop on all type of displays without programing any display / landing module.
Programabile marking by parameters on CPU.
• Delay for stopping are programable for each stop and direction.
• More than 100 programable different timers.
• 256 last error and warning in real time with additional description (stop, drection of travel, state of door, etc.)
• Daily, monthly, yearly and user defined travel counters
• Integrated software for rescue system by standard UPS.
• All display units in red and blue colors. Other colors on request.
• Monitoring system via internet, ethernet, gsm modem.
LC100
SYSTEM
5
6
CABLE
LC100
MRL 120
LC100
SYSTEM
7
LC100
MRL400
LC100
MRL650
LC100
SYSTEM
8
LC100
SYSTEM
9
LC100
SYSTEM
L-1 L-2 L-3 (standard)
10
L-D
C. O. P.
SP-1 TFT Display.
SP-2 DOT MATRIX Display.
P-4
P-1
P-5
P-2
SP-1 (standard)
SP-2
P-6
P-3
P-7
11
L. O. P.
12
M6-R
M5-R
M7-R
M8-R
TFT-LTFT-M
M8-B M8-W
M7-B M7-W
M6-B
M5-B
M6-W
M5-W
DOT
TFT
2 x 7
SEGMENT
DOT
MATRIX
13
LC100-C
LC100-K
LC100-Z
LC100-S
LC100
MODULE
14
LC100-H
LC100-J
LC100-F
LC100-E2
LC100-RLC100-T
LC100
MODULE
15
LC100-PL
LC100-K2
LC100-VFD
LC100-SR
LC100
MODULE
16
LC100-A
LC100-LLLC100-V
LC100-W2LC100-Y
LC100-V2LC100-I
LC100
MODULE
17
LC100-G
LC100-B
LC100-D LC100 Monitoringsystem
LC100
MODULE
22 N. Plastira str. Sykies Thessaloniki Greece
Tel. 0030 2314 31 91 93, 0030 2310 62 82 70
www.dc-services.gr • dcservices.gr@gmail.com • kiorpes@dc-services.gr

dc-services LIFT SOLUTIONS

  • 1.
  • 2.
    4 Μicroprocesor system forlift control MAIN FEATURES/1 • Up to 40 stops, each stop determinated as A or B side. • Up to 8 lifts in multiplex work. • CAN communication between modules. • Small dimensions. • Central procesor unit (CPU) width 72 mm. • Control panel width 120 mm for roomless lift. • Landing modules with integrated arrows and dot matrix display width 42 mm suitable for new instalation and modernization, fixed on landing plate with can / power connector for next stop without additional box in shaft. • Landing modules for landing calls connection and different displays with different protocols (for example TFT,LCD,...) • LCD module for monitoring, adjustment and transfer parameters in LC100-C, adjust VVVF, load mesurement device, connectable on any module in system (control panel, module on the top of car, displays, any landing modules). • One travelling cable (18 + 2x2x0.5) with connectors on both sides. • All equipments in control panel, on cabine, in shaft, car operating panel, landing operating panels are plugable with connectors PLUG & PLAY system. • Teleservis through internet from any point in the world with monitoring, adjusting and analyzing all I/O, calls, parameters, statistic, errors and warnings. MAIN FEATURES / 2 • Software in all modules for all application is same. Differences in applications have to select only by parameters in CPU and by address on landing modules. • Multiplex system without any necessary additional module. • All inputs have galvanic isolation, and they are equipt by LED diode. • All inputs / outputs on all modules are programable with user defined function and polarity. All input and output are predefined for all aplication. • All landing modules are also displays or interface for displays. • Programabile marking for each stop on all type of displays without programing any display / landing module. Programabile marking by parameters on CPU. • Delay for stopping are programable for each stop and direction. • More than 100 programable different timers. • 256 last error and warning in real time with additional description (stop, drection of travel, state of door, etc.) • Daily, monthly, yearly and user defined travel counters • Integrated software for rescue system by standard UPS. • All display units in red and blue colors. Other colors on request. • Monitoring system via internet, ethernet, gsm modem. LC100 SYSTEM
  • 3.
  • 4.
  • 5.
  • 6.
  • 7.
  • 8.
    L-1 L-2 L-3(standard) 10 L-D C. O. P.
  • 9.
    SP-1 TFT Display. SP-2DOT MATRIX Display. P-4 P-1 P-5 P-2 SP-1 (standard) SP-2 P-6 P-3 P-7 11 L. O. P.
  • 10.
  • 11.
  • 12.
  • 13.
  • 14.
  • 15.
  • 16.
    22 N. Plastirastr. Sykies Thessaloniki Greece Tel. 0030 2314 31 91 93, 0030 2310 62 82 70 www.dc-services.gr • dcservices.gr@gmail.com • kiorpes@dc-services.gr