Submit Search
Upload
IRJET- Mollification Parameter Control by Dynamic Voltage Restorer (DVR)
•
0 likes
•
6 views
IRJET Journal
Follow
https://www.irjet.net/archives/V5/i3/IRJET-V5I3270.pdf
Read less
Read more
Engineering
Report
Share
Report
Share
1 of 6
Download now
Download to read offline
Recommended
IRJET- Compensation of Voltage Sag and Voltage Swell by using the Power E...
IRJET- Compensation of Voltage Sag and Voltage Swell by using the Power E...
IRJET Journal
Compensation of Balanced and Unbalanced Voltage Disturbance using SRF Control...
Compensation of Balanced and Unbalanced Voltage Disturbance using SRF Control...
IRJET Journal
Contemporary Control of DG Integrated DVR for Sag, Swell and Harmonic Mitigat...
Contemporary Control of DG Integrated DVR for Sag, Swell and Harmonic Mitigat...
IJECEIAES
IRJET- A Review on Improvement of Power Quality and Displacement Factor u...
IRJET- A Review on Improvement of Power Quality and Displacement Factor u...
IRJET Journal
Mitigation of Voltage Sags & Swells in LV Distribution System Using Dynamic V...
Mitigation of Voltage Sags & Swells in LV Distribution System Using Dynamic V...
IRJET Journal
Analysis of Total Harmonic Distortion (THD) Level of Distribution Network Usi...
Analysis of Total Harmonic Distortion (THD) Level of Distribution Network Usi...
IJERA Editor
Bo36390397
Bo36390397
IJERA Editor
Sag mitigation in distribution system by using Dynamic voltage Restorer (DVR)
Sag mitigation in distribution system by using Dynamic voltage Restorer (DVR)
IJERA Editor
Recommended
IRJET- Compensation of Voltage Sag and Voltage Swell by using the Power E...
IRJET- Compensation of Voltage Sag and Voltage Swell by using the Power E...
IRJET Journal
Compensation of Balanced and Unbalanced Voltage Disturbance using SRF Control...
Compensation of Balanced and Unbalanced Voltage Disturbance using SRF Control...
IRJET Journal
Contemporary Control of DG Integrated DVR for Sag, Swell and Harmonic Mitigat...
Contemporary Control of DG Integrated DVR for Sag, Swell and Harmonic Mitigat...
IJECEIAES
IRJET- A Review on Improvement of Power Quality and Displacement Factor u...
IRJET- A Review on Improvement of Power Quality and Displacement Factor u...
IRJET Journal
Mitigation of Voltage Sags & Swells in LV Distribution System Using Dynamic V...
Mitigation of Voltage Sags & Swells in LV Distribution System Using Dynamic V...
IRJET Journal
Analysis of Total Harmonic Distortion (THD) Level of Distribution Network Usi...
Analysis of Total Harmonic Distortion (THD) Level of Distribution Network Usi...
IJERA Editor
Bo36390397
Bo36390397
IJERA Editor
Sag mitigation in distribution system by using Dynamic voltage Restorer (DVR)
Sag mitigation in distribution system by using Dynamic voltage Restorer (DVR)
IJERA Editor
International Journal of Engineering Research and Development
International Journal of Engineering Research and Development
IJERD Editor
Research Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and Science
researchinventy
IRJET- Power Quality Improvement using Dynamic Voltage Restorer (DVR)
IRJET- Power Quality Improvement using Dynamic Voltage Restorer (DVR)
IRJET Journal
IRJET-Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of...
IRJET-Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of...
IRJET Journal
A0460109
A0460109
IOSR Journals
Iaetsd minimization of voltage sags and swells using dvr
Iaetsd minimization of voltage sags and swells using dvr
Iaetsd Iaetsd
IRJET-Power Quality Improvement by using CHB Inverter based DVR
IRJET-Power Quality Improvement by using CHB Inverter based DVR
IRJET Journal
IRJET- Fault Ride through Technique of DFIG Under Faults by using DVR
IRJET- Fault Ride through Technique of DFIG Under Faults by using DVR
IRJET Journal
To Diminish the Voltage Sag Replaced DVR with Generalized Modulation Strategy...
To Diminish the Voltage Sag Replaced DVR with Generalized Modulation Strategy...
IRJET Journal
11.voltage dip mitigation in distribution system by using d statcom
11.voltage dip mitigation in distribution system by using d statcom
Alexander Decker
IRJET- Dynamic Voltage Restorer for Voltage Sag/Swell Mitigation
IRJET- Dynamic Voltage Restorer for Voltage Sag/Swell Mitigation
IRJET Journal
Power Quality Improvement using DVR (Dynamic Voltage Restorer) Under Various ...
Power Quality Improvement using DVR (Dynamic Voltage Restorer) Under Various ...
IRJET Journal
STATE OF THE ART: DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT
STATE OF THE ART: DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT
ecij
A New Structure of Dynamic Voltage Restorer Based on Asymmetrical ī-source In...
A New Structure of Dynamic Voltage Restorer Based on Asymmetrical ī-source In...
International Journal of Power Electronics and Drive Systems
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
IJERD Editor
F01233345
F01233345
IOSR Journals
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dyna...
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dyna...
IJAPEJOURNAL
DESIGN AND SIMULATION OF DYNAMIC VOLTAGE RESTORER (DVR)
DESIGN AND SIMULATION OF DYNAMIC VOLTAGE RESTORER (DVR)
Journal For Research
Sag/Swell Compensation by using BES DVR in Industrial Drives Applications
Sag/Swell Compensation by using BES DVR in Industrial Drives Applications
IRJET Journal
Power quality improvement using dvr
Power quality improvement using dvr
chandu87
Mitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
Mitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
IOSR Journals
Simulation of DVR by using Ultra Capacitor to Analysis of THD with and withou...
Simulation of DVR by using Ultra Capacitor to Analysis of THD with and withou...
IRJET Journal
More Related Content
What's hot
International Journal of Engineering Research and Development
International Journal of Engineering Research and Development
IJERD Editor
Research Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and Science
researchinventy
IRJET- Power Quality Improvement using Dynamic Voltage Restorer (DVR)
IRJET- Power Quality Improvement using Dynamic Voltage Restorer (DVR)
IRJET Journal
IRJET-Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of...
IRJET-Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of...
IRJET Journal
A0460109
A0460109
IOSR Journals
Iaetsd minimization of voltage sags and swells using dvr
Iaetsd minimization of voltage sags and swells using dvr
Iaetsd Iaetsd
IRJET-Power Quality Improvement by using CHB Inverter based DVR
IRJET-Power Quality Improvement by using CHB Inverter based DVR
IRJET Journal
IRJET- Fault Ride through Technique of DFIG Under Faults by using DVR
IRJET- Fault Ride through Technique of DFIG Under Faults by using DVR
IRJET Journal
To Diminish the Voltage Sag Replaced DVR with Generalized Modulation Strategy...
To Diminish the Voltage Sag Replaced DVR with Generalized Modulation Strategy...
IRJET Journal
11.voltage dip mitigation in distribution system by using d statcom
11.voltage dip mitigation in distribution system by using d statcom
Alexander Decker
IRJET- Dynamic Voltage Restorer for Voltage Sag/Swell Mitigation
IRJET- Dynamic Voltage Restorer for Voltage Sag/Swell Mitigation
IRJET Journal
Power Quality Improvement using DVR (Dynamic Voltage Restorer) Under Various ...
Power Quality Improvement using DVR (Dynamic Voltage Restorer) Under Various ...
IRJET Journal
STATE OF THE ART: DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT
STATE OF THE ART: DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT
ecij
A New Structure of Dynamic Voltage Restorer Based on Asymmetrical ī-source In...
A New Structure of Dynamic Voltage Restorer Based on Asymmetrical ī-source In...
International Journal of Power Electronics and Drive Systems
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
IJERD Editor
F01233345
F01233345
IOSR Journals
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dyna...
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dyna...
IJAPEJOURNAL
DESIGN AND SIMULATION OF DYNAMIC VOLTAGE RESTORER (DVR)
DESIGN AND SIMULATION OF DYNAMIC VOLTAGE RESTORER (DVR)
Journal For Research
Sag/Swell Compensation by using BES DVR in Industrial Drives Applications
Sag/Swell Compensation by using BES DVR in Industrial Drives Applications
IRJET Journal
Power quality improvement using dvr
Power quality improvement using dvr
chandu87
What's hot
(20)
International Journal of Engineering Research and Development
International Journal of Engineering Research and Development
Research Inventy : International Journal of Engineering and Science
Research Inventy : International Journal of Engineering and Science
IRJET- Power Quality Improvement using Dynamic Voltage Restorer (DVR)
IRJET- Power Quality Improvement using Dynamic Voltage Restorer (DVR)
IRJET-Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of...
IRJET-Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of...
A0460109
A0460109
Iaetsd minimization of voltage sags and swells using dvr
Iaetsd minimization of voltage sags and swells using dvr
IRJET-Power Quality Improvement by using CHB Inverter based DVR
IRJET-Power Quality Improvement by using CHB Inverter based DVR
IRJET- Fault Ride through Technique of DFIG Under Faults by using DVR
IRJET- Fault Ride through Technique of DFIG Under Faults by using DVR
To Diminish the Voltage Sag Replaced DVR with Generalized Modulation Strategy...
To Diminish the Voltage Sag Replaced DVR with Generalized Modulation Strategy...
11.voltage dip mitigation in distribution system by using d statcom
11.voltage dip mitigation in distribution system by using d statcom
IRJET- Dynamic Voltage Restorer for Voltage Sag/Swell Mitigation
IRJET- Dynamic Voltage Restorer for Voltage Sag/Swell Mitigation
Power Quality Improvement using DVR (Dynamic Voltage Restorer) Under Various ...
Power Quality Improvement using DVR (Dynamic Voltage Restorer) Under Various ...
STATE OF THE ART: DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT
STATE OF THE ART: DYNAMIC VOLTAGE RESTORER FOR POWER QUALITY IMPROVEMENT
A New Structure of Dynamic Voltage Restorer Based on Asymmetrical ī-source In...
A New Structure of Dynamic Voltage Restorer Based on Asymmetrical ī-source In...
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
Mitigation of Voltage Sag/Swell with Fuzzy Control Reduced Rating DVR
F01233345
F01233345
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dyna...
Compensation of Single-Phase and Three-Phase Voltage Sag and Swell Using Dyna...
DESIGN AND SIMULATION OF DYNAMIC VOLTAGE RESTORER (DVR)
DESIGN AND SIMULATION OF DYNAMIC VOLTAGE RESTORER (DVR)
Sag/Swell Compensation by using BES DVR in Industrial Drives Applications
Sag/Swell Compensation by using BES DVR in Industrial Drives Applications
Power quality improvement using dvr
Power quality improvement using dvr
Similar to IRJET- Mollification Parameter Control by Dynamic Voltage Restorer (DVR)
Mitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
Mitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
IOSR Journals
Simulation of DVR by using Ultra Capacitor to Analysis of THD with and withou...
Simulation of DVR by using Ultra Capacitor to Analysis of THD with and withou...
IRJET Journal
Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of Volta...
Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of Volta...
IRJET Journal
Simulation of DVR for power Quality Improvement by using Ultra Capacitor
Simulation of DVR for power Quality Improvement by using Ultra Capacitor
IRJET Journal
IRJET - Design and Simulation of DSTATCOM using Fuzzy Logic Controller
IRJET - Design and Simulation of DSTATCOM using Fuzzy Logic Controller
IRJET Journal
IRJET- PV System Connected High Step-Up Boost DC-DC Converter based Voltag...
IRJET- PV System Connected High Step-Up Boost DC-DC Converter based Voltag...
IRJET Journal
Voltage sag mitigation using supercapacitor based dynamic voltage restorer
Voltage sag mitigation using supercapacitor based dynamic voltage restorer
eSAT Publishing House
IRJET- Detection and Measurement of Power Quality Parameter
IRJET- Detection and Measurement of Power Quality Parameter
IRJET Journal
IRJET- Modeling, Simulation and Implementation of D-STATCOM for Improveme...
IRJET- Modeling, Simulation and Implementation of D-STATCOM for Improveme...
IRJET Journal
N01041106112
N01041106112
IOSR Journals
Gr3412151231
Gr3412151231
IJERA Editor
POWER QUALITY IMPROVEMENT IN ELECTRICAL RAILWAY POWER SYSTEM
POWER QUALITY IMPROVEMENT IN ELECTRICAL RAILWAY POWER SYSTEM
IRJET Journal
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
IRJET Journal
IRJET- Voltage Drop Compensation in Distribution System using Cascaded H-Brid...
IRJET- Voltage Drop Compensation in Distribution System using Cascaded H-Brid...
IRJET Journal
Control Scheme for Solar PV System under Asymmetrical Fault Condition
Control Scheme for Solar PV System under Asymmetrical Fault Condition
IRJET Journal
IRJET-PV Based Single Phase ZSI using Shoot through Technique
IRJET-PV Based Single Phase ZSI using Shoot through Technique
IRJET Journal
Compensation of Sag and Swell Voltage by using Dynamic Voltage Restorer
Compensation of Sag and Swell Voltage by using Dynamic Voltage Restorer
ijtsrd
Voltage dip mitigation in distribution system by using d statcom
Voltage dip mitigation in distribution system by using d statcom
Alexander Decker
Similar to IRJET- Mollification Parameter Control by Dynamic Voltage Restorer (DVR)
(18)
Mitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
Mitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
Simulation of DVR by using Ultra Capacitor to Analysis of THD with and withou...
Simulation of DVR by using Ultra Capacitor to Analysis of THD with and withou...
Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of Volta...
Simulation and Modeling of Dynamic Voltage Restorer for Compensation Of Volta...
Simulation of DVR for power Quality Improvement by using Ultra Capacitor
Simulation of DVR for power Quality Improvement by using Ultra Capacitor
IRJET - Design and Simulation of DSTATCOM using Fuzzy Logic Controller
IRJET - Design and Simulation of DSTATCOM using Fuzzy Logic Controller
IRJET- PV System Connected High Step-Up Boost DC-DC Converter based Voltag...
IRJET- PV System Connected High Step-Up Boost DC-DC Converter based Voltag...
Voltage sag mitigation using supercapacitor based dynamic voltage restorer
Voltage sag mitigation using supercapacitor based dynamic voltage restorer
IRJET- Detection and Measurement of Power Quality Parameter
IRJET- Detection and Measurement of Power Quality Parameter
IRJET- Modeling, Simulation and Implementation of D-STATCOM for Improveme...
IRJET- Modeling, Simulation and Implementation of D-STATCOM for Improveme...
N01041106112
N01041106112
Gr3412151231
Gr3412151231
POWER QUALITY IMPROVEMENT IN ELECTRICAL RAILWAY POWER SYSTEM
POWER QUALITY IMPROVEMENT IN ELECTRICAL RAILWAY POWER SYSTEM
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
OVER-CURRENT RELAYS IN VOLTAGE DISTRIBUTION
IRJET- Voltage Drop Compensation in Distribution System using Cascaded H-Brid...
IRJET- Voltage Drop Compensation in Distribution System using Cascaded H-Brid...
Control Scheme for Solar PV System under Asymmetrical Fault Condition
Control Scheme for Solar PV System under Asymmetrical Fault Condition
IRJET-PV Based Single Phase ZSI using Shoot through Technique
IRJET-PV Based Single Phase ZSI using Shoot through Technique
Compensation of Sag and Swell Voltage by using Dynamic Voltage Restorer
Compensation of Sag and Swell Voltage by using Dynamic Voltage Restorer
Voltage dip mitigation in distribution system by using d statcom
Voltage dip mitigation in distribution system by using d statcom
More from IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
IRJET Journal
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
IRJET Journal
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
IRJET Journal
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
IRJET Journal
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
IRJET Journal
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
IRJET Journal
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
IRJET Journal
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
IRJET Journal
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
IRJET Journal
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
IRJET Journal
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
IRJET Journal
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
IRJET Journal
React based fullstack edtech web application
React based fullstack edtech web application
IRJET Journal
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
IRJET Journal
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
IRJET Journal
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
IRJET Journal
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
IRJET Journal
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
IRJET Journal
More from IRJET Journal
(20)
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
React based fullstack edtech web application
React based fullstack edtech web application
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Recently uploaded
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
srsj9000
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
Asst.prof M.Gokilavani
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
rehmti665
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
Chandu841456
DATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage example
PragyanshuParadkar1
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
Asst.prof M.Gokilavani
EduAI - E learning Platform integrated with AI
EduAI - E learning Platform integrated with AI
koyaldeepu123
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
Introduction to Machine Learning Unit-3 for II MECH
Introduction to Machine Learning Unit-3 for II MECH
C Sai Kiran
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
NikhilNagaraju
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Anamika Sarkar
Arduino_CSE ece ppt for working and principal of arduino.ppt
Arduino_CSE ece ppt for working and principal of arduino.ppt
SAURABHKUMAR892774
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
GDSCAESB
Effects of rheological properties on mixing
Effects of rheological properties on mixing
viprabot1
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
PoojaBan
Work Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvv
LewisJB
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
VICTOR MAESTRE RAMIREZ
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
9953056974 Low Rate Call Girls In Saket, Delhi NCR
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Dr.Costas Sachpazis
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
dollysharma2066
Recently uploaded
(20)
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
Call Girls Delhi {Jodhpur} 9711199012 high profile service
Call Girls Delhi {Jodhpur} 9711199012 high profile service
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
DATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage example
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
CCS355 Neural Network & Deep Learning UNIT III notes and Question bank .pdf
EduAI - E learning Platform integrated with AI
EduAI - E learning Platform integrated with AI
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
young call girls in Rajiv Chowk🔝 9953056974 🔝 Delhi escort Service
Introduction to Machine Learning Unit-3 for II MECH
Introduction to Machine Learning Unit-3 for II MECH
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Study on Air-Water & Water-Water Heat Exchange in a Finned Tube Exchanger
Arduino_CSE ece ppt for working and principal of arduino.ppt
Arduino_CSE ece ppt for working and principal of arduino.ppt
GDSC ASEB Gen AI study jams presentation
GDSC ASEB Gen AI study jams presentation
Effects of rheological properties on mixing
Effects of rheological properties on mixing
Heart Disease Prediction using machine learning.pptx
Heart Disease Prediction using machine learning.pptx
Work Experience-Dalton Park.pptxfvvvvvvv
Work Experience-Dalton Park.pptxfvvvvvvv
Software and Systems Engineering Standards: Verification and Validation of Sy...
Software and Systems Engineering Standards: Verification and Validation of Sy...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
🔝9953056974🔝!!-YOUNG call girls in Rajendra Nagar Escort rvice Shot 2000 nigh...
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
Call Us ≽ 8377877756 ≼ Call Girls In Shastri Nagar (Delhi)
IRJET- Mollification Parameter Control by Dynamic Voltage Restorer (DVR)
1.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 03 | Mar-2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1190 Mollification Parameter Control By Dynamic Voltage Restorer (DVR) Sunny Dhoke1, Roshan Mohabe2, Dhiraj Satkar3, Nagmanaj Pathan4 1,2,3 Student, Dept. of Electrical Engineering, W.C.E.M. Nagpur, Maharashtra, India 4Professor, Dept. of Electrical Engineering, W.C.E.M. Nagpur, Maharashtra, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract -For electrical engineering, the noteworthy topic is power quality. Power quality problem is an occurrence demonstrated as a nonstandard current, voltage orfrequency. Electrical failures and service disruption canbefoundinutility distribution networks, detracting commercial operation and sensitive industrial loads which causes heavy financial losses. Voltage sag is one of the major problems that will be dealt here. Dynamic Voltage Restorer is a series connected device based on power electronics which can quickly mollify the voltagesag in the system and restore the load voltage to the pre-fault value. Mollification of the power quality problem is made possibleby the increasing development in power electronics. This work focuses on the major problem of voltage sag. Voltage sag problems are mollified by devices such as UPFC, tap changing transformer, STATCOM and DVR. Between these devices dynamic voltage restorer provides the most economical and commercial answer to mollify voltage sag by injecting power as well as voltage into the system. This thesis gives an introduction to significant power quality problems for DVR and power electronics controllers for voltagesag mollification. Then operation hardware and elements in DVR is explained. This thesis gives the idea of using of the error signal to control the triggering of the switches of an inverter using Sinusoidal Pulse Width Modulation (SPWM) technique. Key Words: Static Series Compensator (SSC), Dynamic Voltage Restorer (DVR), Mollification, Peripheral Interface Controller (PIC). 1. INTRODUCTION The typical power quality disturbances are voltage sags, voltage swells, intermission, phase shifts, harmonics and transients. Among the interference, voltagesagisconsidered the most severe since the sensitive loads are very impressionable to temporary changes in the voltage. “Authenticity” is a key word for utilities and their customers in general, and it is very important to companies operating in a highly competitive business environment, it affectsprofitability and also is a driving force intheindustry. A very high level of authenticity has been reached by the electrical transmission and distribution systems, there cannot be any disturbances that can be avoided. Problems related with operation of electrical and electronic devices can be caused by any disturbancesto voltage.Thereisaneed of constant frequency, constant sine wave shape and symmetrical voltage with a constant peak to peak value to continue the production. The wide area solution is required to alleviate voltage sags and improve power quality. One of thenewestapproach is using a DVR . The basic operational principle is injecting the missing voltage in series to the bus and detecting the voltage sag by zero crossing detector. DVR hasbecomeacost effective solution for the protection of non-linear loadsfrom voltage sags. The DVR is efficient, quick and flexible solution to voltage sag problems. DVR consists of capacitor bank storage unit, PWM inverter, and filter and booster transformer. It is well known that power quality is facing various difficultiessuch asvoltage sags/swells, flicker,surge,voltage imbalance, harmonic distortion and interruptions, fretting fatigue. Voltage sags/swells can occur more regularly than other power quality problems, also these sags/swellsarethe most serious power quality disturbances in the power distribution system. Dynamic Voltage Restorer (DVR) is one of the most important custom power devicesthat have been created to improve the performance of power quality. The DVR balances the load voltage at a nominal magnitude and phase by settling the voltage sag/swell. These systems can compensate voltage sags by increasing the appropriate voltages in cascade with the supply voltage, and therefore prevent loss of power. 2. METHODOLOGY Fig -1: Block diagram of the role of dynamic voltage restorer in improving power quality. 2.1.1 Basic Configuration: Some of the basic elements of a DVR are as follows: Converter L&C filter Booster transformer DC-link and paper capacitor storage unit DC-link and energy storage By-pass equipment Disconnecting equipment
2.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 03 | Mar-2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1191 The converter is most likely a Voltage Source Converter (VSC), which sinusoidal Pulse Width modulates(SPWM) the DC from the DC-link/storage to AC-voltagesinjectedintothe system. A VSC is a power electronic system,whichconsistsof capacitor storage and switching devices, which can generated a sinusoidal voltage at required constant frequency, magnitude, and phase angle. In the DVR application, the VSC is used to transitory replace the supply voltage or to generate the part of the supply voltage whichis missing. There are four main types of switching devices: Light Activated Silicon Controlled Rectifier (LA-SCR), Gate Turn-Off thyristor (GTO), Power Metal OxideSemiconductor Field Effect Transistors (P-MOSFET), Integrated Gate Commutated Thyristor (IGCT) and Insulated Gate Bipolar Transistors (IGBT). Each type of power electronicdevicehas its own advantages and limitation. The IGCT is a newly compact device which is having authenticity and enhanced performance that allows VSC to build with very large power ratings. Because of the highly practiced converter design with IGCTs, the DVR can balance dips which are above the capability of the past DVRs using conventional devices. The purpose of such devices is to supply the necessary energy to the VSC using a dc link for the generation of injected voltages. 2.1.2 L&C Filter: To reduce the switching harmonics generated by the SPWM VSC L&C filters are used. 2.1.3 Booster Transformer: In most DVR applications the DVR is equipped with injection transformers to certify galvanic isolation and protection equipment and for simplification oftheconverter topology. The Booster transformer is a specially designed transformer that tries to limit the coupling of transient energy and noise from the primary side to the secondary side. The key tasks are: 1) It connects the DVR to the distribution network using the HV-windings. The voltage source converter to the incoming supply voltage generates injecting series compensating voltage. 2) Also, the Booster transformer can be used for the purpose of isolating the load from the system. 2.1.4 DC-Link and Energy Storage: The VSC uses a DC-link voltage to synthesize an AC voltage into the grid. During a majorityofvoltageimmersion, restoration of supply voltage is necessary for active power injection. The dc charging circuit has two important tasks. 1) The first task of the DC-link and storage is to charge the energy source after a sag compensation incident. 2) The second task is to maintain dc link voltage at the apparent dc link voltage. 2.1.5 By-Pass Equipment: During faults, overload and service a circumvent pathfor the load current has to be secured. When the sag on line is detected, DC storage unit is fed to PWM inverter. 2.1.6 DVR topology with no energy storage: DVR topologies used with no energy storage on dc link, Part of the supply voltage remains present during the sag and this residual supply can be used to provide thecapacitor boost energy required to maintain full load power at rated voltage. A passive shunt converter is used because only unidirectional power flow is required necessary and it is cheap solution for voltage sag. Two main topologies can be used, which are required to be categorized hereaccordingto the location of shunt converter with series compensation. 2.1.7 Dynamic Voltage Restorer: In year of 1994, L. Gyugyi proposed a device and a method for dynamic voltage restoration of utility as per required in distribution network. This method uses active power in order to inject the faulted supply voltages and is locally known as the Dynamic Voltage Restorer. In this paper, a DVR design is essentially contains a voltage source inverter (VSI), an series injection transformer connected between the AC voltage supply and the non -linear load,aDC energy storage capacitor, and a control system as shown in Figure 2. Fig -2: Basic DVR topology The main function of the DVR is the protection of non- linear loads from voltage sags/swells expected from the network. The DVR is connected in series between thesource voltage or grid of distribution and no-linear loads through series injection transformer. There are one of several types of energy storage that has been used in the DVR such as battery, paper capacitance and superconducting coil. These types of energy storages are very important in order to
3.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 03 | Mar-2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1192 supply real and imaginary power to the DVR. The controller is more important part of the DVR for switching purposes. The switching converter is responsible to conversion process from DC to AC and to make sure that’s only the swell or sag voltage is injected to the series injection transformer. The three-phase transformersconnection used in the three- phase DVR can be constructed either in delta/open or star/open connection. In case of asymmetrical fault on high voltage side, the zero sequence current flowing almost zero, if the distribution transformer connection in Ä-Y with the grounded neutral. In such a way of connection, the DVR is only used for the allegation of the positive and negative sequence. 3. COMPENSATION METHODS OF DVR The type of the compensation technique mainly depends upon the specified factors such as DVR power ratings, various conditions of load, voltage sag type & swell. Some loads are non-linear towards phase angle l jump and some are sensitive towards change in magnitude and others are tolerant to these. Therefore, the control strategies mainly depend upon the type of load characteristics; therearethree different methods of DVR seriesvoltage injection which are: (a) Pre-sag compensation (b) In-phase compensation (c)Voltage tolerance method with minimumenergy injection 3.1.1 Pre-Sag/Dip Compensation Method: The pre-sag method detects the supply voltage continuously and if it detects any disturbances in supply voltage by micro-controller it will inject the difference voltage between the sag and pre-fault condition, so that the load voltage can be restored by back to the pre-fault condition. Compensation of voltage sagsin both phase angle and amplitude. Non-linear loads would be achieved by pre- sag compensation method. In this technique the series injected real power cannot be controlled and it is calculated by external conditions such as the type of faults and load conditions. The voltage of DVR is given below: VDVR = Vpre fault – Vsag Fig -3: Phasor diagram of pre-sag/dip method 3.1.2 In-Phase Compensation Method: In this method the injected voltage is in phase with the supply side voltage regardless of the load current and pre- fault voltage. The phase angles of the pre-sag and load voltage are not similar but the vital criteria forpowerquality that is the constant magnitude of load voltage are fulfilled. The load voltage is given below: |VL| = |Vpre-fault| One of the advantagesof this technique is that the amplitude of DVR injection voltage is minimum for some voltage sag in comparison with different strategies. Practicalapplicationof this technique is in non-sensitive loads to phase angle jump. Fig -4: Phasor diagram of in-phase method 3.1.3 Voltage Tolerance Method with Minimum Energy Injection: A small jump in phase angle and a small drop in voltage can be tolerated by the load itself. If the phase angle variations between 5% -10% of nominal state and voltage magnitude lies between 90%-110% of nominal state that will not disturb the operational featuresof loads.Bothphase and magnitude are the control parameter for this method and can be achieved by small energy injection. In this technique, the magnitude and phase angle of corrected load voltage inside the area of load voltage tolerancearechanged. The phase angle jump and voltage drop on load can be accepted by load itself. The delicacy of loads to voltage magnitude and phase angle jump is different. 4. PROPOSED CONTROL TECHNIQUE The control system of a DVR plays a vital role, with the operational requirements of fast response when voltage sag/swells are occur. When voltage sag or swells are detected, the DVR must react as fast as possible and should inject AC voltage to the grid. It can be implemented by using a Space Vector PWM control technique which isbasedonthe voltage reference and instantaneous values of load voltage and supply. There are many basic rules of a controller in a DVR that is the detection of the voltage sag or swell occurrencesin the system; generation of thetriggerpulsesof
4.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 03 | Mar-2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1193 PWM inverter, calculation of the compensating voltage and stop triggering pulses when the occurrence has passed. The dq method gives the information of the phase shift (q) and depth (d) of voltage sag with start and end time. The load voltage is converted to VD, VQ and V0 based on park transformation according equations (1), (2) & (3). 4.1.1 Components and their rating: Sr. No. Component Rating 1 PIC Microcontroller 32-Bit 2 Series Inverter 1kV 3 Thyristor 0.5kV 4 Capacitor Bank 300kVAR 5 Potential Transformer 230/5V 6 Zero Crossing Detector 5V 7 Opto-coupler 12V 8 Regulator IC 5V 9 Line Frequency 50Hz 10 Filter Inductance 7mH 11 Filter Capacitance 10μF 4.1.2 Design Criteria and Rated Power Calculations: (1) Design criteria: The design of the DVR is affected by the sensitive load, the supply characteristicsand by the expected voltage-dip characteristics. When designing for a DVR for certain application, the following items should be considered: Maximum load power and power factor: The load size strongly affects the current rating of the voltage-source converter and the injection transformer as well as the need of energy storage needed. Maximum depth and duration of voltage dips to be corrected: These characteristics together with the load size, dictates the necessary storage capacity of the energy storage device. The maximum duration and penetration of voltage dips to be corrected is determined by the statistics of the voltage dips at the DVR location and by the acceptable number of equipment trips. Maximum allowed voltage drop of the DVR during the standby mode: This effect is only for controlling mode during normal operation and indirectly the reaction speed at the beginning of a voltage dip. Parameters of the step-down transformers: Coupling of the step-down transformer (CIA or YIY, etc.) at input and output sides of the DVR. Harmonic requirements of the load and of the system: These affect the harmonic filtering needed for the DVR and also influence the choice of charging method for the capacitors. At the first instance when designing a DVR, some assumption could be made to simplify the analysis, such as: Ideal switches DC-side capacitors are large enough to maintain a ripple free DC bus voltage, even for unbalanced input voltage. Series transformer and output filter components are ideal. In order to design a DVR, the concept of “boost rating” is introduced to define themaximumvoltage that the DVR is capable to inject into the power line with respect to the nominal distribution system voltage. (2) Rated power calculations: The DVR function, in case of voltage collapse, is for exchange real power between the power system and the energy storage device. The real power injected by the DVR is an important feature to precede its design process. To calculate the active and the reactive power, a factor is defined to indicate the reduction of the positive sequence voltage with respect to the nominal voltage of the load. For a certain supply voltage U, and required load voltage UL, the DVR injected voltage is written as: Uc = UL –Us = (1-MF) UL The range of the modulus of MF is defined by the maximum variation of Us, for which the DVR is designed. So, in normal operation MF should be unity and Uc is zero. MF = Us/ UL
5.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 03 | Mar-2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1194 Considering the fact that the DVR current shouldbe designed to be the same as the rated load current, the apparent power required by the DVR is then calculated in terms of the apparent load power, SL and MF by the following formula. Sc = SL (1- MF) Consequently, the active and reactive powers are calculated by separating Sc into its real and imaginary parts as Where cos (ΦS) is the source power factor and cos(ΦL) is the load power factor. 5. HARDWARE DESIGN This is the hardware implementation of Dynamic Voltage Restorer (DVR) designed for mollification of voltage sags. The arrangement is of 10 sub-circuits as shown in the LA- SCR’s, DVR coupling network, Opto coupler circuit, Isolated power supply circuit, Lamp load, Line Impedance, PIC microcontroller circuit,1:1 isolated transformer, and the 3 transformers are: 1) For DVR DC Supply, 2) For trigger circuit, 3) For control circuit In the below diagram, the 230V, 50 HZ supply is isolated by means of a 1:1 (230/230), 150VA isolationtransformer.This isolated voltage is further steady state as the line voltage, which supplies power to the load, through simulated line impedance. The simulated line impedance is simply a wire wound resistor. To have maximum effect of voltage drop acrossthe line impedance, the resistance valueconsideredis of very high value, 120 Ohms. After this simulated line impedance, a switch is connected, through which the load can be connected or disconnected. In the recurring path, the DVR output is connected through the output winding of the coupling transformer developed.ThisoutputfromtheDVRis connected in series with the load, and mitigates the line impedance effect. The DVR circuit has to check the load voltage and need to be connected to the micro controller circuit and correct the voltage if there is any excess or absence when compared to a Reference voltage, by injecting appropriate voltage into the circuit by means of thecoupling network. The authors can acknowledge any person/authorities in this section. This is not mandatory. Fig -5: Hardware demonstration of Dynamic Voltage Restorer (DVR). 6. DYNAMIC VOLTAGE RESTORER The functioning and designing of different blocksofdynamic voltage restorer is discussed herewith. a) Single phase voltage source bridge inverter: The voltage source inverter used in the DVR circuit makes the induction of required voltage with required phase possible. This inverter uses dc capacitors as the supply and can switch at a high frequency to generate asignalwhichwill mitigate the voltage sags and swells across the load. b) Micro controller circuit: The microcontroller circuit is the heart of the system, and is responsible for generating the reference voltage waveform from the voltage waveform that is sampled from the sensing network, which it has obtained from the reference voltage sensing circuit. This reference voltage waveform is generated keeping the zero crossing as the reference to maintain the phase relationship of the load and correcting voltage. As the voltage induced through the coupling transformer, generated by the bridge inverter, the resulted voltage across the load will be a pure sinusoid of required voltage. c) Opto coupler and driver circuits: Opto couplers are having the capability of transferring an electrical signal between two circuits while electrically isolating the circuitsfrom each other. They generallyconsist of an infrared LED, light emitting section at the input and a silicon photo detector at the output. The input for opto- couplers can be either AC or DC, which can drive the LED. d) Coupling network: The voltage waveform for mitigating the voltage variations in the load circuit is achieved with the voltage source inverter, coupling transformer and an interfacing filter. The coupling transformer needs to transfer energy from the
6.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 03 | Mar-2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1195 voltage source inverter to the load and at thesametimeneed to provide low impedance on the load side, so that the transformer winding itself doesn‟t provide a voltage drop across the load. e) Inverter driving circuitry: In order to trigger the LA-SCR, it is required to apply a +12V pulse to make it turn ‘ON’ and -12V pulse to turn it ‘OFF’ to the gate with respect to its emitter. Thus, in order to provide triggering pulses to each and every MOSFET, it is requiredto have four isolated power supplies of ± 12V which can be used to apply trigger pulses to the respective MOSFETs. This inverter provides the required outputs, which can be used to drive the opto-coupler secondary side, which is meant for driving the LA-SCR gate. f) Isolated power supplies for filter elements: Three different power supplies are required, to provide power to various blocks of the over-all DVR circuit. 7. CONCLUSION In this paper, hardware model of DVR is setup.Theproposed method is used for identification of the voltage sag and is capable of mollification of the sag by keeping and maintaining the magnitude of load voltage at the voltage which is desired and THD within limits. The proposed method is very easy to understand and is reliable, has been used only for one switching per phase. Hence the system is easy, simple, but requires energy storage device as compared to commonly usedDVRorSTATCOM.Theworking performance of the proposed device is verifiedbytheoretical results and is found to be satisfactory. This is the best control technique for non-linear loadswhichcan’twithstand for phase angle jumps is pre-sag compensation. For minimum voltage injection, in-phase injectioncompensation is the best. For minimum energy insertion by the DVR,phase advance compensation is best but requires more voltage injection. REFERENCES [1] A.A.D.R. Perera, D.M. Vilathgamuwa, S.S. Choi,“Voltage Sag Compensation with Energy Optimized Dynamic Voltage Restorer”, IEEE Trans. on Power Del., Vol. 11, No. 3, pp. 928-936, July 2003. [2] V. Salehi, S. Kahrobaee, S. Afsharnia, “Power Flow Control and Power Quality Improvement of Wind Turbine Using Universal Custom Power Conditioner”, IEEE Conference on Industrial Electronics, Vol. 4, pp. 1688-1892, July 2002. [3] B.H. Li, S.S. Choi, D.M. Vilathgamuwa, “Design Considerations on the Line-Side Filter Used in the Dynamic Voltage Restorer”, IEE Proc. Gener. Transmission Distrib., Issue 1, Vol. 148, pp. 1-7, Jan. 2001. [4] H.P. Tiwari, Sunil Kumar Gupta, “DC Energy Storage Schemes for DVR Voltage Sag Mitigation System” International Journal of Computer Theory and Engineering, Vol. 2, No. 3, June, 2010.K. Elissa, “Title of paper if known,” unpublished. [5] P. Boonchiam,N. Mithulananthan, “Understanding of Dynamic Voltage Restorers through Matlab Simulation” Thammasat Int. J. Sc. Tech., Vol. 11, No. 3, July-Sept. 2006. [6] “Control and Testing of a Dynamic Voltage Restorer (DVR) at medium Voltage Level,”IEEE Transactions on Power Electronics.Vol.19, no.3, MAY 2004. [7] “Dynamic Voltage Restoration with Minimum Energy Injection,” IEEE Transactions on Power Systems,Vol.15, No.1, February 2000. [8] N.G.Hingorani, “Introducing custom power”, IEEE Spectrum, pp.41-48, June 1995. [9] M.F.McGrandghan, D.R.Mueller,andM.J.Samotyj.”Voltage sags in industrial systems”, IEEE Trans. On industry applications, Vol.29, no.2,pp.397-402,March/ April 1993. [10] S.W.Middlekauff and E.R.Collins Jr. “System and customer impact consideration for seriescustompower devices,” IEEE Trans. On power Delivery, Vol. 13, no.1, pp. 278-282,Jan. 1998 [11] T.Wunderlin, P.Dahler, D.Amhof, and H.Gruning,“Power supply quality improvement with a dynamic voltage restorer (DVR) “, in proceedings of EMPD‟98,Singapore, Mar.3-5, 1998 pp.518-525. [12] A.Compos and G.Joos et.al. “ Analysis and design of a series voltage unbalance compensator based onathree- phase VSI operating with unbalanced switching functions”, IEEE Trans. On Power Electronics, Vol.9, No.3, pp. 269-274, may 1994. [13] R.Buxton, “Protection from voltage dips with the dynamic voltage restorer”, in IEEE Half Day colloquium on Dynamic Voltage Restorer, London, 1998, Digest No. 1998/189. [14] G.Nielsen, F.Blaabjerg, and N.Mohan,” control strategies for dynamic voltage restorer compensatingvoltagesaga with phase jump,” in proc, IEEE/APEC‟01 Conference, Vol. 2, 2001, pp.1267-1273. [15] N.H.Woodly, L.Morgan, and A.Sundaram, “Experience with an inverter-based dynamic voltage restorer,” IEEE Trans. Power delivery, Vol.14, pp.1181-1186, July1999. [16] “UNDERSTANDING POWER QUALITY PROBLEMS”, Voltage sags and interruptions Math H.J.Bollen-IEEE PRESS.
Download now