International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3731
“Comparative Seismic Analysis of RC G+13 MultiStorey Building Frame”
Rahul Kumar Thakur1, Mayank Kushwaha2, Vikrant Sharma3, Prof. R. K. Vishwakarma4
1,2,3 BE Students, Department of Civil Engineering, Takshshila Inst. Of Engineering & Tech., Jabalpur, M.P. India
4Assistant Professor, Department of Civil Engineering, Takshshila Inst. of Engineering & Tech. Jabalpur, M.P. India
---------------------------------------------------------------------***---------------------------------------------------------------------
Abstract – In this research project work, we analyzed the
Seismic analysis of RC (G+13) Multi-storey building frame
structure in different seismic zone by using Linear Static
Methods in a Staad Pro V8i. We considered different soil
condition and different parameter like size of column
450x450mm, size of beam 230x450mm, thickness of slab
150mm, height of each floors 3m. The comparative analysis of
the building frame in the term of Node displacement,
Maximum Shear Force, MaximumBendingMoment, Maximum
Axial forces. The comparative analysis results observed that
As per the results shows that maximum node displacement,
shear force and bending moment in zone V in soft soil while
minimum at zone II and hard soil. It means that, of we
increased the zones the node displacement is also increased.
The results in the term of support reaction shows that zone II,
III & IV are same with all type of soils but increased with
change the zone from IV to zone V with softsoil. Themaximum
storey-wise displacement founded in zone V with soft soil and
minimum at zone II with hard soil and also shows that if we
increased the number of storey, node displacement is also
increased.
Key Words: RC Building Frame, Staad Pro., Soil, Zone etc.
1. INTRODUCTION
In India, we know that the Earthquakes are most
unpredictable and devastating of all-natural disasters and
have the potential for causing the greatest injured among all
the natural hazards. Since Seismic forces or earthquake
forces are random in nature and unpredictable. They not
only cause great harm in human casualties, but also have a
huge economic impact on the affected area. The concern
about earthquake hazards has led to an increasing
awareness and demand for any structure designed to
withstand earthquake forces. When a structure is subjected
to ground motions during earthquake, it responds by
vibrating and those ground motion causes the structure to
shake or vibrate in all the directions which the predominant
direction of shaking is horizontal. During an earthquake,the
effect in a structure generally initiates at location of the
structural weakness present in the building systems which
also depends upon the location of seismic zone. High-Rise
Reinforced Concrete structures are a special class of
structures with their own peculiar characteristics and
requirements for analysis and design.
B. Gireesh Babu (2017) , studied that the Conventional
Concrete Design and seismic analysis and design of G+7
storey Residential building in seismic zone II by using Staad
pro Software. He analyzed the 2-D frame and the different
parameters used like RF =3 for OMRF and importancefactor
=1. He observed that the quantity of steel increased in the
conventional concrete design resultinginthegroundfloorto
higher floors as compared to Staad Pro.
Vikash Mehta, KanchanRana April-Sept. 2017 , studied
that the seismic analysis of Multi-storey Regular Building
(G+25) in Seismic Zone V by using Time Historymethod and
Response Spectrum Method in a StaadProSoftwareasper IS
1893 (Part-I) 2002. He found that the storey drift slightly
decreased while increased storey displacement with
increased the storey heights.
Dr. Syed Aqueel Ahmad, Rajiv Banarjee et.al. (2018) ,
studied that Seismic Analysis & Designing of G+10 Storied
Building by Strut & Staad pro Softwarewithdifferentloading
conditions and compared the results.Heobservedthatshear
wall should be placed at a point by coinciding the center of
gravity and centroid of the building.
A Primary Objective of this research works per IS 1893
(Part-I) 2002
(a) To performed the Seismic Analysis of RC building
framed structure by using Staad Prof. software.
(b) To comparative Study of Seismic Analysis of Building
Frame Structure considered with different zone.
(c) To Comparative Analysis of Building frame with
different soil conditions.
2. SEISMIC EFFECTS
It has been seen in past earthquake effects that the building
structures zone V and Soft soils are more damage. This force
cause damages to building structures, for instance, loss of
wealth and life in the building structures and if the force of
effects is high it prompts breakdown of the structure. As we
know that, In the past years population has been extended
and a result of which urban zones and towns have started to
make different storey of building. In light of this reason,
different structures are being locally seismic zones. Now a
days, India has an extensive shoreline forefront which is
secured with mountains and slopes, like Various resorts are
being produced in uneven zones to give courses of action to
guests. The structures in these zones are created on sloping
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3732
grounds. In India, a huge part of the rough ranges go under
the seismic zone(II, III and IV) which determinesitsintensity
as zone II is low where chances of occurrence of earthquake
is low whereas zoneV is verysevere which means chancesof
earthquake is very high in this areas. In such case building
frail against seismic tremor.
Different Seismic Zone in India: As per IS 1893 Part I.
As per Indian Slandered Code IS 1893:2002, the Vibration
and Intensity due to seismic waves are calculated,where the
design horizontal seismic coefficient Ah can be calculated by
the expression:
Where Z = zone factor given in table 2 in IS 1893:2002
Table 1.1 : Seismic Zone and Intensity
Seismic
Zone
II III IV V
Intensity Low Moderate Severe Very Severe
Z 0.1 0.16 0.24 0.36
3. METHODOLOGY
In the recent time, Civil & Structural software’s analysis is
more effectively used in analysis and design of differentcivil
engineering structures. In this work, we using Staad pro
software and analyzed the structure as per IS 1893:2002.
The following steps are adopted:
Step-1 Modeling of building frame in Node & Transitional
repeat with different type of soils, symmetrical
(24.02mX24.02m)G+13 story of 3D frame. Fig. 2.1
Fig. 2.1 Plan of Building
Step-2 Selection of Building Geometry: Plan of Building
24.02mX24.02m , Size of Columns 450mmX450mm, Size of
Beam 230mm X 450mm,ThicknessofSlab150mm;Heightof
each floor 3.0m, Unit weight of RCC 25KN/m3, Unitweightof
bricks 20KN/m3 and Fixed supports.
Step-3 selection of Seismic Zone and soil conditions As per
IS Code.
Step-4 Load combinations.
Load case
no.
Load cases
1 DL
2 LL
3 EQ,X+
4 EQ,X-
5 E.Q,Z+
6 E.Q,Z-
7 1.5(DL+LL)
8 1.5(DL+E.Q.,X)
9 1.5(DL-E.Q.,X)
10 1.5(DL+E.Q.,Z)
11 1.5 (DL-E.Q.,Z)
12 1.2( DL+LL+E.Q.,X)
13 1.2 (D.L+L.L-E.Q.,X)
14 1.2 (DL+LL+E.Q.,Z)
15 1.2 (DL+LL-E.Q.,Z)
Step-5 Designing of building frames using STAAD.Pro v8i
software in 3D rendered view.
Step-6 Analysis considering different types of soil
condition providing different seismic zones.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3733
Step-7 Comparative the results in the term of storey-wise
displacement, shear force, bending moment, node
displacement etc.
FLOW CHART DIAGRAM:
For this Project Work, Flow chart of proposedmethodofthis
analysis.
Fig. Flow Chart Diagram
4. RESULTS AND ANALYSIS
Maximum Node Displacement (mm).
ZONE
MAXIMUM DISPLACEMENT IN X
DIRECTION IN mm
SOFT MEDIUM HARD
II 90.622 73.844 54.361
III 144.852 118.008 86.834
IV 217.158 176.892 130.131
V 325.618 265.218 195.077
Maximum Shear Forces (KN)
ZONE
MAXIMUM SHEAR FORCE IN X
DIRECTION IN KN
SOFT MEDIUM HARD
II 151.269 140.138 133.275
III 204.076 176.714 148.738
IV 277.777 236.734 189.071
V 388.329 326.764 255.27
Maximum Bending Moment (KN-m)
ZONE
MAXIMUM B.M. IN X DIRECTION IN
KN-M
SOFT MEDIUM HARD
II 188.369 167.615 144.634
III 257.581 222.921 183.667
IV 353.26 299.701 238.574
V 509.944 420.81 323.889
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3734
Maximum Support Reaction (KN)
ZONE
SOIL CONDITIONS
SOFT MEDIUM HARD
II 5177.04 5177.04 5177.04
III 5177.04 5177.04 5177.04
IV 5177.04 5177.04 5177.04
V 5439.906 5177.04 5177.04
Maximum Storey Displacement (mm) in Soft Soil
STOREY
ZONE-
II
ZONE-
III
ZONE-
IV
ZONE-V
13th Floor 90.622 144.852 217.158 325.618
12th Floor 88.498 141.583 212.364 318.538
11th Floor 85.328 136.522 204.78 307.167
10th Floor 80.903 129.442 194.162 291.241
9th Floor 75.407 120.649 180.971 271.454
8th Floor 69.033 110.45 165.672 248.504
7th Floor 61.971 99.149 148.719 223.075
6th Floor 54.366 86.98 130.465 195.693
5th Floor 46.363 74.175 111.257 166.881
4th Floor 38.092 60.94 91.404 137.1
3rd Floor 29.664 47.454 71.174 106.754
2nd Floor 21.181 33.88 50.812 76.211
1st Floor 12.777 20.434 30.646 45.965
GF 4.907 7.85 11.774 17.659
BASE 0 0 0 0
Maximum Storey Displacement (mm) in Medium Soil
STOREY
ZONE-
II
ZONE-III ZONE-IV ZONE-V
13th Floor 73.844 118.008 176.892 265.218
12th Floor 72.074 115.305 172.947 259.411
11th Floor 64.251 111.181 166.768 250.149
10th Floor 65.886 105.415 158.121 237.179
9th Floor 61.411 98.254 147.378 221.065
8th Floor 56.22 89.948 134.919 202.376
7th Floor 50.469 80.745 121.114 181.667
6th Floor 44.276 70.835 106.248 159.368
5th Floor 37.759 60.408 90.607 135.905
4th Floor 31.024 49.63 74.439 111.653
3rd Floor 24.16 38.648 57.965 86.94
2nd Floor 17.252 27.594 41.382 62.067
1st Floor 10.408 16.644 24.958 37.434
GF 3.999 6.393 9.589 14.382
BASE 0 0 0 0
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3735
Maximum Storey Displacement (mm) in Hard Soil in
STOREY ZONE-II
ZONE-
III
ZONE-IV ZONE-V
13th Floor 54.361 86.834 130.131 195.077
12th Floor 53.001 84.789 127.173 190.748
11th Floor 51.097 81.752 122.625 183.935
10th Floor 48.446 77.512 116.266 174.397
9th Floor 45.156 72.247 108.368 162.549
8th Floor 41.34 66.14 99.207 148.807
7th Floor 37.111 59.374 89.056 133.581
6th Floor 32.558 52.087 78.126 117.185
5th Floor 27.767 44.421 66.625 117.185
4th Floor 22.815 36.496 54.738 82.101
3rd Floor 17.769 28.421 42.625 63.93
2nd Floor 12.689 20.294 30.432 45.641
1st Floor 7.658 12.242 18.356 27.527
GF 2.948 4.702 7.046 10.575
BASE 0 0 0 0
5. CONCLUSION
As per the results shows that maximum node displacement,
shear force and bending moment in zone V in soft soil while
minimum at zone II and hard soil. It means that, of we
increased the zones the node displacement isalsoincreased.
The results in the term of support reaction shows that zone
II, III & IV are same with all type of soils but increased with
change the zone from IV to zone V with soft soil. The
maximum storey-wise displacement founded in zone V with
soft soil and minimum at zone II with hard soil and also
shows that if we increased the number of storey, node
displacement is also increased.
6. REFERANCES
1. Vikas Mehta1 , Kanchan Rana2, A Time History
Analysis Method for Studying the Multi-storeyed
Building Using STAAD Pro International Journal of
Civil and Structural Engineering Research ISSN
2348-7607 (Online) Vol. 5, Issue 1, pp: (57-64),
Month: April - September 2017
2. Md. Arman1 Mr. Anwar Ahmad2 Dr. Syed Aqueel
Ahmad3 Mr. Rajiv Banarjee4 Analysis & Designing
G+10 Storied Building by Struds & STAAD Pro
Software & Comparing the Design Results.
3. Umakant Arya, Aslam Hussain, Waseem Khan,
“Wind Analysis of Building Frames on Sloping
Ground”. International Journal of Scientific and
Research Publications,Issn 2250-3153 Volume 4,
Issue 5, May 2014.
4. B. Gireesh Babu Seismic Analysis and Design of G+7
Residential Building Using STAADPRO,IJRRIIT
(Volume3, Issue3)
5. Vrushali S. Kalsait 1, Valsson Varghese, “Design of
Earthquake Resistant Multistoried Building On A
Sloping Ground”. IJISET - International Journal of
Innovative Science, Engineering & Technology,ISSN
2348 – 7968. Vol. 2 Issue 7, July 2015
6. Paul D.K. and Kumar S. Stability Analysis of Slope
with Building Loads. Soil Dynamics and Earthquake
Engineering, 16, 395-405,(1997).
7. Vijaya Narayanan,et. al, “Performance of RC
Buildings along Hill Slope of Himalaya during 2011
Sikkim Earthquake”, EERI Newsletter, EERI Special
Earthquake Report,1-14, February 2012.
8. Dr. S. A. Halkude, Mr. M. G. Kalyanshetti, Mr. V. D.
Ingle “Seismic Analysis of Buildings resting on
sloping grounds with varying Number of bays and
hill Slopes”, International Journal of Engineering
Research and Technology, ISSN: 2278-0181, VOL 2,
ISSUE 12, December 2013.

More Related Content

What's hot

IRJET- Seismic Evaluation of Reinforced Concrete Building with Friction Dampers
IRJET- Seismic Evaluation of Reinforced Concrete Building with Friction DampersIRJET- Seismic Evaluation of Reinforced Concrete Building with Friction Dampers
IRJET- Seismic Evaluation of Reinforced Concrete Building with Friction DampersIRJET Journal
 
IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...
IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...
IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...IRJET Journal
 
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...IRJET Journal
 
IRJET- Design and Testing of Savonius Water Turbine for Parshall Flume
IRJET- Design and Testing of Savonius Water Turbine for Parshall FlumeIRJET- Design and Testing of Savonius Water Turbine for Parshall Flume
IRJET- Design and Testing of Savonius Water Turbine for Parshall FlumeIRJET Journal
 
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET Journal
 
IRJET - Study of Seismic Retrofitting Techniques
IRJET - Study of Seismic Retrofitting TechniquesIRJET - Study of Seismic Retrofitting Techniques
IRJET - Study of Seismic Retrofitting TechniquesIRJET Journal
 
IRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced Frames
IRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced FramesIRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced Frames
IRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced FramesIRJET Journal
 
Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...
Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...
Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...shankar kumar
 
IRJET- Analysis of G+15 Building Different Seismic Zones of India
IRJET-  	  Analysis of G+15 Building Different Seismic Zones of IndiaIRJET-  	  Analysis of G+15 Building Different Seismic Zones of India
IRJET- Analysis of G+15 Building Different Seismic Zones of IndiaIRJET Journal
 
IRJET- A Review on Comparative Studies on Seismic Analysis of Multi-Story...
IRJET-  	  A Review on Comparative Studies on Seismic Analysis of Multi-Story...IRJET-  	  A Review on Comparative Studies on Seismic Analysis of Multi-Story...
IRJET- A Review on Comparative Studies on Seismic Analysis of Multi-Story...IRJET Journal
 
IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...
IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...
IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...IRJET Journal
 
IRJET- Wind Load Analysis for Different Configuration of Structures
IRJET- Wind Load Analysis for Different Configuration of StructuresIRJET- Wind Load Analysis for Different Configuration of Structures
IRJET- Wind Load Analysis for Different Configuration of StructuresIRJET Journal
 
IRJET- Performance based Seismic Analysis and Design of Building Resting ...
IRJET-  	  Performance based Seismic Analysis and Design of Building Resting ...IRJET-  	  Performance based Seismic Analysis and Design of Building Resting ...
IRJET- Performance based Seismic Analysis and Design of Building Resting ...IRJET Journal
 
IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...
IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...
IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...IRJET Journal
 
IRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABS
IRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABSIRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABS
IRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABSIRJET Journal
 
Response of Segmental Bridge when Subjected to Seismic Excitation
Response of Segmental Bridge when Subjected to Seismic ExcitationResponse of Segmental Bridge when Subjected to Seismic Excitation
Response of Segmental Bridge when Subjected to Seismic ExcitationIRJET Journal
 
IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...
IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...
IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...IRJET Journal
 
IRJET- Study on Optimum Location of Shear Wall in Tall Buildings Against ...
IRJET-  	  Study on Optimum Location of Shear Wall in Tall Buildings Against ...IRJET-  	  Study on Optimum Location of Shear Wall in Tall Buildings Against ...
IRJET- Study on Optimum Location of Shear Wall in Tall Buildings Against ...IRJET Journal
 
IRJET- Comparative Study of R.C.C and Steel (G+4 Storey) Building
IRJET-  	  Comparative Study of R.C.C and Steel (G+4 Storey) BuildingIRJET-  	  Comparative Study of R.C.C and Steel (G+4 Storey) Building
IRJET- Comparative Study of R.C.C and Steel (G+4 Storey) BuildingIRJET Journal
 
IRJET- Analysis of Steel Framed Structure using Steel Bracing System for ...
IRJET-  	  Analysis of Steel Framed Structure using Steel Bracing System for ...IRJET-  	  Analysis of Steel Framed Structure using Steel Bracing System for ...
IRJET- Analysis of Steel Framed Structure using Steel Bracing System for ...IRJET Journal
 

What's hot (20)

IRJET- Seismic Evaluation of Reinforced Concrete Building with Friction Dampers
IRJET- Seismic Evaluation of Reinforced Concrete Building with Friction DampersIRJET- Seismic Evaluation of Reinforced Concrete Building with Friction Dampers
IRJET- Seismic Evaluation of Reinforced Concrete Building with Friction Dampers
 
IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...
IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...
IRJET- Response of Buildings with and Without Setbacks Subjected to Earthquak...
 
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
 
IRJET- Design and Testing of Savonius Water Turbine for Parshall Flume
IRJET- Design and Testing of Savonius Water Turbine for Parshall FlumeIRJET- Design and Testing of Savonius Water Turbine for Parshall Flume
IRJET- Design and Testing of Savonius Water Turbine for Parshall Flume
 
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
 
IRJET - Study of Seismic Retrofitting Techniques
IRJET - Study of Seismic Retrofitting TechniquesIRJET - Study of Seismic Retrofitting Techniques
IRJET - Study of Seismic Retrofitting Techniques
 
IRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced Frames
IRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced FramesIRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced Frames
IRJET- Seismic Analysis of a Multi-Storey Building using Steel Braced Frames
 
Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...
Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...
Id 165-rapid seismic vulnerability evaluation of residential buildings in aga...
 
IRJET- Analysis of G+15 Building Different Seismic Zones of India
IRJET-  	  Analysis of G+15 Building Different Seismic Zones of IndiaIRJET-  	  Analysis of G+15 Building Different Seismic Zones of India
IRJET- Analysis of G+15 Building Different Seismic Zones of India
 
IRJET- A Review on Comparative Studies on Seismic Analysis of Multi-Story...
IRJET-  	  A Review on Comparative Studies on Seismic Analysis of Multi-Story...IRJET-  	  A Review on Comparative Studies on Seismic Analysis of Multi-Story...
IRJET- A Review on Comparative Studies on Seismic Analysis of Multi-Story...
 
IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...
IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...
IRJET- A Parametric Study on the Seismic Behaviour of Flat Slab Multi-Storied...
 
IRJET- Wind Load Analysis for Different Configuration of Structures
IRJET- Wind Load Analysis for Different Configuration of StructuresIRJET- Wind Load Analysis for Different Configuration of Structures
IRJET- Wind Load Analysis for Different Configuration of Structures
 
IRJET- Performance based Seismic Analysis and Design of Building Resting ...
IRJET-  	  Performance based Seismic Analysis and Design of Building Resting ...IRJET-  	  Performance based Seismic Analysis and Design of Building Resting ...
IRJET- Performance based Seismic Analysis and Design of Building Resting ...
 
IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...
IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...
IRJET-Seismic Analysis of the Multistory Building Frames with different Geome...
 
IRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABS
IRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABSIRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABS
IRJET- Analysis & Design of Reinforced Concrete Building (G+4) using ETABS
 
Response of Segmental Bridge when Subjected to Seismic Excitation
Response of Segmental Bridge when Subjected to Seismic ExcitationResponse of Segmental Bridge when Subjected to Seismic Excitation
Response of Segmental Bridge when Subjected to Seismic Excitation
 
IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...
IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...
IRJET- Evaluation of R.C. Multi-Storey Building Response under the Effect of ...
 
IRJET- Study on Optimum Location of Shear Wall in Tall Buildings Against ...
IRJET-  	  Study on Optimum Location of Shear Wall in Tall Buildings Against ...IRJET-  	  Study on Optimum Location of Shear Wall in Tall Buildings Against ...
IRJET- Study on Optimum Location of Shear Wall in Tall Buildings Against ...
 
IRJET- Comparative Study of R.C.C and Steel (G+4 Storey) Building
IRJET-  	  Comparative Study of R.C.C and Steel (G+4 Storey) BuildingIRJET-  	  Comparative Study of R.C.C and Steel (G+4 Storey) Building
IRJET- Comparative Study of R.C.C and Steel (G+4 Storey) Building
 
IRJET- Analysis of Steel Framed Structure using Steel Bracing System for ...
IRJET-  	  Analysis of Steel Framed Structure using Steel Bracing System for ...IRJET-  	  Analysis of Steel Framed Structure using Steel Bracing System for ...
IRJET- Analysis of Steel Framed Structure using Steel Bracing System for ...
 

Similar to IRJET- Comparative Seismic Analysis of RC G+13 Multistorey Building Frame

SEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE II
SEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE IISEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE II
SEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE IIIRJET Journal
 
IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...
IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...
IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...IRJET Journal
 
IRJET- Seismic Analysis of various Shapes of Building
IRJET- Seismic Analysis of various Shapes of BuildingIRJET- Seismic Analysis of various Shapes of Building
IRJET- Seismic Analysis of various Shapes of BuildingIRJET Journal
 
IRJET- Analysis of Tall Building Structure Subjected to Wind and Earthqua...
IRJET-  	  Analysis of Tall Building Structure Subjected to Wind and Earthqua...IRJET-  	  Analysis of Tall Building Structure Subjected to Wind and Earthqua...
IRJET- Analysis of Tall Building Structure Subjected to Wind and Earthqua...IRJET Journal
 
A Study on the Impact of Seismic Performance on RCC Frames
A Study on the Impact of Seismic Performance on RCC FramesA Study on the Impact of Seismic Performance on RCC Frames
A Study on the Impact of Seismic Performance on RCC FramesIRJET Journal
 
IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...
IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...
IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...IRJET Journal
 
IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...
IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...
IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...IRJET Journal
 
Seismic Evaluation of Multi-Storey Building using E-tabs
Seismic Evaluation of Multi-Storey Building using E-tabsSeismic Evaluation of Multi-Storey Building using E-tabs
Seismic Evaluation of Multi-Storey Building using E-tabsIRJET Journal
 
Seismic Analysis of RCC Building without and With Shear Walls
Seismic Analysis of RCC Building without and With Shear WallsSeismic Analysis of RCC Building without and With Shear Walls
Seismic Analysis of RCC Building without and With Shear WallsIRJET Journal
 
“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...
“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...
“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...IRJET Journal
 
Effect of shear wall position in multi-storied building
Effect of shear wall position in multi-storied buildingEffect of shear wall position in multi-storied building
Effect of shear wall position in multi-storied buildingIRJET Journal
 
Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...
Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...
Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...IRJET Journal
 
SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...
SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...
SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...IRJET Journal
 
Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...
Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...
Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...IRJET Journal
 
IRJET- Effective Location of Shear Wall on Performance of Building Frame ...
IRJET-  	  Effective Location of Shear Wall on Performance of Building Frame ...IRJET-  	  Effective Location of Shear Wall on Performance of Building Frame ...
IRJET- Effective Location of Shear Wall on Performance of Building Frame ...IRJET Journal
 
COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...
COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...
COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...IRJET Journal
 
IRJET- Design of Earthquake Resistant Structure of Multi-Story RCC Building
IRJET-  	  Design of Earthquake Resistant Structure of Multi-Story RCC BuildingIRJET-  	  Design of Earthquake Resistant Structure of Multi-Story RCC Building
IRJET- Design of Earthquake Resistant Structure of Multi-Story RCC BuildingIRJET Journal
 
Comparative Analysis of an RC framed building under Seismic Conditions
Comparative Analysis of an RC framed building under Seismic ConditionsComparative Analysis of an RC framed building under Seismic Conditions
Comparative Analysis of an RC framed building under Seismic ConditionsIRJET Journal
 
IRJET- Comparative Analysis of Seismic Performance of R.C Building Restin...
IRJET-  	  Comparative Analysis of Seismic Performance of R.C Building Restin...IRJET-  	  Comparative Analysis of Seismic Performance of R.C Building Restin...
IRJET- Comparative Analysis of Seismic Performance of R.C Building Restin...IRJET Journal
 

Similar to IRJET- Comparative Seismic Analysis of RC G+13 Multistorey Building Frame (20)

SEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE II
SEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE IISEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE II
SEISMIC ANALYSIS AND DESIGN OF MULTI-STOREY BUILDING IN STAAD PRO FOR ZONE II
 
IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...
IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...
IRJET- Seismic Analysis and Design of Multistorey Building in Different Seism...
 
IRJET- Seismic Analysis of various Shapes of Building
IRJET- Seismic Analysis of various Shapes of BuildingIRJET- Seismic Analysis of various Shapes of Building
IRJET- Seismic Analysis of various Shapes of Building
 
IRJET- Analysis of Tall Building Structure Subjected to Wind and Earthqua...
IRJET-  	  Analysis of Tall Building Structure Subjected to Wind and Earthqua...IRJET-  	  Analysis of Tall Building Structure Subjected to Wind and Earthqua...
IRJET- Analysis of Tall Building Structure Subjected to Wind and Earthqua...
 
A Study on the Impact of Seismic Performance on RCC Frames
A Study on the Impact of Seismic Performance on RCC FramesA Study on the Impact of Seismic Performance on RCC Frames
A Study on the Impact of Seismic Performance on RCC Frames
 
IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...
IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...
IRJET- Minimization of Effect of Soft Storey During Earthquake by Providing S...
 
IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...
IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...
IRJET- Analysis and Design of G+6 Building in Different Seismic Zones by usin...
 
Seismic Evaluation of Multi-Storey Building using E-tabs
Seismic Evaluation of Multi-Storey Building using E-tabsSeismic Evaluation of Multi-Storey Building using E-tabs
Seismic Evaluation of Multi-Storey Building using E-tabs
 
Seismic Analysis of RCC Building without and With Shear Walls
Seismic Analysis of RCC Building without and With Shear WallsSeismic Analysis of RCC Building without and With Shear Walls
Seismic Analysis of RCC Building without and With Shear Walls
 
“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...
“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...
“STUDY ON SEISMIC BEHAVIOR OF IRREGULAR BUILDING WITH AND WITHOUT SHEAR WALL ...
 
Effect of shear wall position in multi-storied building
Effect of shear wall position in multi-storied buildingEffect of shear wall position in multi-storied building
Effect of shear wall position in multi-storied building
 
ppt 19p31d8705.pptx
ppt 19p31d8705.pptxppt 19p31d8705.pptx
ppt 19p31d8705.pptx
 
Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...
Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...
Critical Comparative Study of Dynamic Wind Response of Tall Buildings Using G...
 
SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...
SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...
SEISMIC ANALYSIS OF MULTISTOREY BUILDING FRAME RESTING ON PLANE AND SLOPING G...
 
Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...
Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...
Comparative Study of Commercial High-Rise Building with Flat Slab by Varying ...
 
IRJET- Effective Location of Shear Wall on Performance of Building Frame ...
IRJET-  	  Effective Location of Shear Wall on Performance of Building Frame ...IRJET-  	  Effective Location of Shear Wall on Performance of Building Frame ...
IRJET- Effective Location of Shear Wall on Performance of Building Frame ...
 
COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...
COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...
COMPARISON OF ANALYSIS AND DESIGN OF REGULAR AND IRREGULAR CONFIGURATION OF M...
 
IRJET- Design of Earthquake Resistant Structure of Multi-Story RCC Building
IRJET-  	  Design of Earthquake Resistant Structure of Multi-Story RCC BuildingIRJET-  	  Design of Earthquake Resistant Structure of Multi-Story RCC Building
IRJET- Design of Earthquake Resistant Structure of Multi-Story RCC Building
 
Comparative Analysis of an RC framed building under Seismic Conditions
Comparative Analysis of an RC framed building under Seismic ConditionsComparative Analysis of an RC framed building under Seismic Conditions
Comparative Analysis of an RC framed building under Seismic Conditions
 
IRJET- Comparative Analysis of Seismic Performance of R.C Building Restin...
IRJET-  	  Comparative Analysis of Seismic Performance of R.C Building Restin...IRJET-  	  Comparative Analysis of Seismic Performance of R.C Building Restin...
IRJET- Comparative Analysis of Seismic Performance of R.C Building Restin...
 

More from IRJET Journal

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...IRJET Journal
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTUREIRJET Journal
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...IRJET Journal
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsIRJET Journal
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...IRJET Journal
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...IRJET Journal
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...IRJET Journal
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...IRJET Journal
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASIRJET Journal
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...IRJET Journal
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProIRJET Journal
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...IRJET Journal
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemIRJET Journal
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesIRJET Journal
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web applicationIRJET Journal
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...IRJET Journal
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.IRJET Journal
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...IRJET Journal
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignIRJET Journal
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...IRJET Journal
 

More from IRJET Journal (20)

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web application
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
 

Recently uploaded

Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxupamatechverse
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...ranjana rawat
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Christo Ananth
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVRajaP95
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escortsranjana rawat
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Call Girls in Nagpur High Profile
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxpurnimasatapathy1234
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 

Recently uploaded (20)

Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptxIntroduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
(SHREYA) Chakan Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Esc...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur EscortsCall Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IVHARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
 
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur EscortsHigh Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Isha Call 7001035870 Meet With Nagpur Escorts
 
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...Top Rated  Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
 
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptxMicroscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 

IRJET- Comparative Seismic Analysis of RC G+13 Multistorey Building Frame

  • 1. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3731 “Comparative Seismic Analysis of RC G+13 MultiStorey Building Frame” Rahul Kumar Thakur1, Mayank Kushwaha2, Vikrant Sharma3, Prof. R. K. Vishwakarma4 1,2,3 BE Students, Department of Civil Engineering, Takshshila Inst. Of Engineering & Tech., Jabalpur, M.P. India 4Assistant Professor, Department of Civil Engineering, Takshshila Inst. of Engineering & Tech. Jabalpur, M.P. India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract – In this research project work, we analyzed the Seismic analysis of RC (G+13) Multi-storey building frame structure in different seismic zone by using Linear Static Methods in a Staad Pro V8i. We considered different soil condition and different parameter like size of column 450x450mm, size of beam 230x450mm, thickness of slab 150mm, height of each floors 3m. The comparative analysis of the building frame in the term of Node displacement, Maximum Shear Force, MaximumBendingMoment, Maximum Axial forces. The comparative analysis results observed that As per the results shows that maximum node displacement, shear force and bending moment in zone V in soft soil while minimum at zone II and hard soil. It means that, of we increased the zones the node displacement is also increased. The results in the term of support reaction shows that zone II, III & IV are same with all type of soils but increased with change the zone from IV to zone V with softsoil. Themaximum storey-wise displacement founded in zone V with soft soil and minimum at zone II with hard soil and also shows that if we increased the number of storey, node displacement is also increased. Key Words: RC Building Frame, Staad Pro., Soil, Zone etc. 1. INTRODUCTION In India, we know that the Earthquakes are most unpredictable and devastating of all-natural disasters and have the potential for causing the greatest injured among all the natural hazards. Since Seismic forces or earthquake forces are random in nature and unpredictable. They not only cause great harm in human casualties, but also have a huge economic impact on the affected area. The concern about earthquake hazards has led to an increasing awareness and demand for any structure designed to withstand earthquake forces. When a structure is subjected to ground motions during earthquake, it responds by vibrating and those ground motion causes the structure to shake or vibrate in all the directions which the predominant direction of shaking is horizontal. During an earthquake,the effect in a structure generally initiates at location of the structural weakness present in the building systems which also depends upon the location of seismic zone. High-Rise Reinforced Concrete structures are a special class of structures with their own peculiar characteristics and requirements for analysis and design. B. Gireesh Babu (2017) , studied that the Conventional Concrete Design and seismic analysis and design of G+7 storey Residential building in seismic zone II by using Staad pro Software. He analyzed the 2-D frame and the different parameters used like RF =3 for OMRF and importancefactor =1. He observed that the quantity of steel increased in the conventional concrete design resultinginthegroundfloorto higher floors as compared to Staad Pro. Vikash Mehta, KanchanRana April-Sept. 2017 , studied that the seismic analysis of Multi-storey Regular Building (G+25) in Seismic Zone V by using Time Historymethod and Response Spectrum Method in a StaadProSoftwareasper IS 1893 (Part-I) 2002. He found that the storey drift slightly decreased while increased storey displacement with increased the storey heights. Dr. Syed Aqueel Ahmad, Rajiv Banarjee et.al. (2018) , studied that Seismic Analysis & Designing of G+10 Storied Building by Strut & Staad pro Softwarewithdifferentloading conditions and compared the results.Heobservedthatshear wall should be placed at a point by coinciding the center of gravity and centroid of the building. A Primary Objective of this research works per IS 1893 (Part-I) 2002 (a) To performed the Seismic Analysis of RC building framed structure by using Staad Prof. software. (b) To comparative Study of Seismic Analysis of Building Frame Structure considered with different zone. (c) To Comparative Analysis of Building frame with different soil conditions. 2. SEISMIC EFFECTS It has been seen in past earthquake effects that the building structures zone V and Soft soils are more damage. This force cause damages to building structures, for instance, loss of wealth and life in the building structures and if the force of effects is high it prompts breakdown of the structure. As we know that, In the past years population has been extended and a result of which urban zones and towns have started to make different storey of building. In light of this reason, different structures are being locally seismic zones. Now a days, India has an extensive shoreline forefront which is secured with mountains and slopes, like Various resorts are being produced in uneven zones to give courses of action to guests. The structures in these zones are created on sloping
  • 2. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3732 grounds. In India, a huge part of the rough ranges go under the seismic zone(II, III and IV) which determinesitsintensity as zone II is low where chances of occurrence of earthquake is low whereas zoneV is verysevere which means chancesof earthquake is very high in this areas. In such case building frail against seismic tremor. Different Seismic Zone in India: As per IS 1893 Part I. As per Indian Slandered Code IS 1893:2002, the Vibration and Intensity due to seismic waves are calculated,where the design horizontal seismic coefficient Ah can be calculated by the expression: Where Z = zone factor given in table 2 in IS 1893:2002 Table 1.1 : Seismic Zone and Intensity Seismic Zone II III IV V Intensity Low Moderate Severe Very Severe Z 0.1 0.16 0.24 0.36 3. METHODOLOGY In the recent time, Civil & Structural software’s analysis is more effectively used in analysis and design of differentcivil engineering structures. In this work, we using Staad pro software and analyzed the structure as per IS 1893:2002. The following steps are adopted: Step-1 Modeling of building frame in Node & Transitional repeat with different type of soils, symmetrical (24.02mX24.02m)G+13 story of 3D frame. Fig. 2.1 Fig. 2.1 Plan of Building Step-2 Selection of Building Geometry: Plan of Building 24.02mX24.02m , Size of Columns 450mmX450mm, Size of Beam 230mm X 450mm,ThicknessofSlab150mm;Heightof each floor 3.0m, Unit weight of RCC 25KN/m3, Unitweightof bricks 20KN/m3 and Fixed supports. Step-3 selection of Seismic Zone and soil conditions As per IS Code. Step-4 Load combinations. Load case no. Load cases 1 DL 2 LL 3 EQ,X+ 4 EQ,X- 5 E.Q,Z+ 6 E.Q,Z- 7 1.5(DL+LL) 8 1.5(DL+E.Q.,X) 9 1.5(DL-E.Q.,X) 10 1.5(DL+E.Q.,Z) 11 1.5 (DL-E.Q.,Z) 12 1.2( DL+LL+E.Q.,X) 13 1.2 (D.L+L.L-E.Q.,X) 14 1.2 (DL+LL+E.Q.,Z) 15 1.2 (DL+LL-E.Q.,Z) Step-5 Designing of building frames using STAAD.Pro v8i software in 3D rendered view. Step-6 Analysis considering different types of soil condition providing different seismic zones.
  • 3. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3733 Step-7 Comparative the results in the term of storey-wise displacement, shear force, bending moment, node displacement etc. FLOW CHART DIAGRAM: For this Project Work, Flow chart of proposedmethodofthis analysis. Fig. Flow Chart Diagram 4. RESULTS AND ANALYSIS Maximum Node Displacement (mm). ZONE MAXIMUM DISPLACEMENT IN X DIRECTION IN mm SOFT MEDIUM HARD II 90.622 73.844 54.361 III 144.852 118.008 86.834 IV 217.158 176.892 130.131 V 325.618 265.218 195.077 Maximum Shear Forces (KN) ZONE MAXIMUM SHEAR FORCE IN X DIRECTION IN KN SOFT MEDIUM HARD II 151.269 140.138 133.275 III 204.076 176.714 148.738 IV 277.777 236.734 189.071 V 388.329 326.764 255.27 Maximum Bending Moment (KN-m) ZONE MAXIMUM B.M. IN X DIRECTION IN KN-M SOFT MEDIUM HARD II 188.369 167.615 144.634 III 257.581 222.921 183.667 IV 353.26 299.701 238.574 V 509.944 420.81 323.889
  • 4. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3734 Maximum Support Reaction (KN) ZONE SOIL CONDITIONS SOFT MEDIUM HARD II 5177.04 5177.04 5177.04 III 5177.04 5177.04 5177.04 IV 5177.04 5177.04 5177.04 V 5439.906 5177.04 5177.04 Maximum Storey Displacement (mm) in Soft Soil STOREY ZONE- II ZONE- III ZONE- IV ZONE-V 13th Floor 90.622 144.852 217.158 325.618 12th Floor 88.498 141.583 212.364 318.538 11th Floor 85.328 136.522 204.78 307.167 10th Floor 80.903 129.442 194.162 291.241 9th Floor 75.407 120.649 180.971 271.454 8th Floor 69.033 110.45 165.672 248.504 7th Floor 61.971 99.149 148.719 223.075 6th Floor 54.366 86.98 130.465 195.693 5th Floor 46.363 74.175 111.257 166.881 4th Floor 38.092 60.94 91.404 137.1 3rd Floor 29.664 47.454 71.174 106.754 2nd Floor 21.181 33.88 50.812 76.211 1st Floor 12.777 20.434 30.646 45.965 GF 4.907 7.85 11.774 17.659 BASE 0 0 0 0 Maximum Storey Displacement (mm) in Medium Soil STOREY ZONE- II ZONE-III ZONE-IV ZONE-V 13th Floor 73.844 118.008 176.892 265.218 12th Floor 72.074 115.305 172.947 259.411 11th Floor 64.251 111.181 166.768 250.149 10th Floor 65.886 105.415 158.121 237.179 9th Floor 61.411 98.254 147.378 221.065 8th Floor 56.22 89.948 134.919 202.376 7th Floor 50.469 80.745 121.114 181.667 6th Floor 44.276 70.835 106.248 159.368 5th Floor 37.759 60.408 90.607 135.905 4th Floor 31.024 49.63 74.439 111.653 3rd Floor 24.16 38.648 57.965 86.94 2nd Floor 17.252 27.594 41.382 62.067 1st Floor 10.408 16.644 24.958 37.434 GF 3.999 6.393 9.589 14.382 BASE 0 0 0 0
  • 5. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 04 | Apr 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 3735 Maximum Storey Displacement (mm) in Hard Soil in STOREY ZONE-II ZONE- III ZONE-IV ZONE-V 13th Floor 54.361 86.834 130.131 195.077 12th Floor 53.001 84.789 127.173 190.748 11th Floor 51.097 81.752 122.625 183.935 10th Floor 48.446 77.512 116.266 174.397 9th Floor 45.156 72.247 108.368 162.549 8th Floor 41.34 66.14 99.207 148.807 7th Floor 37.111 59.374 89.056 133.581 6th Floor 32.558 52.087 78.126 117.185 5th Floor 27.767 44.421 66.625 117.185 4th Floor 22.815 36.496 54.738 82.101 3rd Floor 17.769 28.421 42.625 63.93 2nd Floor 12.689 20.294 30.432 45.641 1st Floor 7.658 12.242 18.356 27.527 GF 2.948 4.702 7.046 10.575 BASE 0 0 0 0 5. CONCLUSION As per the results shows that maximum node displacement, shear force and bending moment in zone V in soft soil while minimum at zone II and hard soil. It means that, of we increased the zones the node displacement isalsoincreased. The results in the term of support reaction shows that zone II, III & IV are same with all type of soils but increased with change the zone from IV to zone V with soft soil. The maximum storey-wise displacement founded in zone V with soft soil and minimum at zone II with hard soil and also shows that if we increased the number of storey, node displacement is also increased. 6. REFERANCES 1. Vikas Mehta1 , Kanchan Rana2, A Time History Analysis Method for Studying the Multi-storeyed Building Using STAAD Pro International Journal of Civil and Structural Engineering Research ISSN 2348-7607 (Online) Vol. 5, Issue 1, pp: (57-64), Month: April - September 2017 2. Md. Arman1 Mr. Anwar Ahmad2 Dr. Syed Aqueel Ahmad3 Mr. Rajiv Banarjee4 Analysis & Designing G+10 Storied Building by Struds & STAAD Pro Software & Comparing the Design Results. 3. Umakant Arya, Aslam Hussain, Waseem Khan, “Wind Analysis of Building Frames on Sloping Ground”. International Journal of Scientific and Research Publications,Issn 2250-3153 Volume 4, Issue 5, May 2014. 4. B. Gireesh Babu Seismic Analysis and Design of G+7 Residential Building Using STAADPRO,IJRRIIT (Volume3, Issue3) 5. Vrushali S. Kalsait 1, Valsson Varghese, “Design of Earthquake Resistant Multistoried Building On A Sloping Ground”. IJISET - International Journal of Innovative Science, Engineering & Technology,ISSN 2348 – 7968. Vol. 2 Issue 7, July 2015 6. Paul D.K. and Kumar S. Stability Analysis of Slope with Building Loads. Soil Dynamics and Earthquake Engineering, 16, 395-405,(1997). 7. Vijaya Narayanan,et. al, “Performance of RC Buildings along Hill Slope of Himalaya during 2011 Sikkim Earthquake”, EERI Newsletter, EERI Special Earthquake Report,1-14, February 2012. 8. Dr. S. A. Halkude, Mr. M. G. Kalyanshetti, Mr. V. D. Ingle “Seismic Analysis of Buildings resting on sloping grounds with varying Number of bays and hill Slopes”, International Journal of Engineering Research and Technology, ISSN: 2278-0181, VOL 2, ISSUE 12, December 2013.