The document analyzes a 15-story irregular building with diagonally stiffened steel plate shear walls (SPSWs) using software to determine storey drift, displacement, and stiffness. It finds that placing diagonally stiffened SPSWs at the building edges rather than the center reduces drift and displacement. Thicker steel plates and diagonal stiffeners increase the overall stiffness of the building structure.