International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1370
Analysis and Comparison of R.C.C Conventional Slab& Flat Slab
Under Seismic & Temperature Load
Faria Aseem1, Waseem Sohail2, Abdul Quadir3
1,2Assistant Professor, Lords Institute of Engineering & Technology, Hyderabad, India
3Sr.Structural Design Engineer, PIL Limited, Hyderabad, India
--------------------------------------------------------------------------------***--------------------------------------------------------------------------------
Abstract— In today’s construction the use of flat slab has
become quite common. Flat-slab building structures
possesses major advantages over traditional slab-beam -
column structures because of the free design of space,
shorter construction time, architectural–functional and
economical aspects. Flat slab construction is a developing
technology in India. The conventional slab has more
stiffness and higher load carrying capacity. Due to
urbanization and aesthetic reasons flat slab have become
quite common. Because of the absence of deep beams and
shear walls, flat-slab structural system is significantly more
flexible for lateral loads then traditional RC frame system.
The performance of flat slab system under temperature
loading is also very poor. It is necessary to analyses seismic
behavior of buildings for various heights to see whatare the
changes that are going to occur for the conventional RC
frame building, flat slab building with and without drops. In
this comparative study, the seismic behavior of R.C.C flat
slab and conventional slab is evaluated by nonlinear time-
history analyses with different temperature loading with
the help of SAP 2000 v18 software. The main parameters
evaluated in this study are lateral displacement, inter story
drift, axial force, and bending moment. A total of 12 models
with three different structural systems i.e., conventional
slab system, flat slab system without drops and flat slab
system with drops are considered. For each structural
system 150mm and 200mm thickness oftheslab is taken, so
we have six basic models. For each basic model G+4, G+8
stories are considered. The performance of flat slab and
conventional slab has to be studied when subjected to
Seismic loading due to occurrence of varying magnitudes of
earthquakes having different frequencies. Thetemperature
loading is being considered due to frequent occurrences of
fire accidents and also due to the need for knowledge in
people about fire hazards. Fire will not onlycausecasualties
but also effect the structure predominantly leading to its
destruction. From results it can be concluded that
conventional slab of 150 mm thickness is more effective for
G+4 & G+8. For normal and high temperature 150mm
thickness is good for G+4, G+8.
Key words: Seismic Design, Temperature Loads, Flat
Slab, Conventional Slab, Non-Linear Time History
I. LITERATURE REVIEW
Kang et al. (2003) studied the constitutive model of
concrete subjected to elevated temperature. The model is
composed of four strain components: free thermal strain,
mechanical strain, thermal creep strain, and transientstrain
due to moisture. The thermal creep strain of concrete is
derived from the modified power-law relation for steady
state creep. Mathematical description on the multi-axial
creep behavior of concrete is also presented. The transient
strain component is made in order to consider rapid
irreversible strain change of moisture diffusion and
evaporation. Some applications for the proposed model are
carried out by a nonlinear analysis and compared with the
test results and it shows that the proposed model gives a
good agreement and the influences of inelastic strain
changes at elevated temperatures are very important for
the structural response at elevated temperatures.
Levesque (2006) presented a simplified design tool which
assesses the fire performance of reinforced concrete. An
Excel-based spreadsheet application was developed for
thermal analysis of concrete slabs. It accounts for different
aggregate types, slab thicknesses,andfireexposures.Several
analyses were performed with the spreadsheet application
to examine the affect slab thickness and aggregate types
have on the fire performance of concrete slabs in standard
and natural fires. The results were comparedwith published
test data and finite element software simulations to
benchmark the accuracy of the proposed tool. Furthermore,
methods for the design of reinforced concrete slabs in fire
conditions are presented. 11Wang (2006) studied that the
membrane forces and the redistribution of bending
moments in the slabs considerably affected the behavior of
the slabs in fire conditions. Consequently, the fire
resistance of the slabs can be enhanced if tensile membrane
behavior is mobilized. This thesis uses a non-linear finite
element program, SAFIR, developed at the University of
Liege, Belgium, to model reinforced concrete flat slabs and
one-way slabs at elevated temperatures. The slabs were
modeled as 3-D shell elements in the numerical structural
models. It was found that the location of the fire under flat
slabs and the arrangement of reinforcing bars in flat slabs
significantly affect the distribution of bending moments
and membrane forces in flat slabs. It was also found that
the worst scenario of fire exposure could be when the flat
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1371
slabs are exposed to fire with a decay phase or after the fire
was exhausted or extinguished. The fire resistance of flat
slabs is significantly increased if tensile membrane action
can be mobilized. However, the distribution of membrane
forces in the slabs is nonlinear.
Rizk (2010) studied the development in concrete
technology over the twentieth century covering materials,
structural systems, analysis and construction techniques
made it possible to build concrete tall buildings such as
PETRONAS towers(452m), jin Mao(421m) and bhurj Dubai
(800+) Manley (2014) presented the use of prescribed
solutions for fire design and has allowed engineers to
simply provide an assembly of elements which meets a
building codes required fire resistance without necessarily
understanding or evaluating the development of a fire in a
compartment, the corresponding temperatures reached
and the implications of such temperatures. A process is
presented which uses simple thermal and mechanical
models to determine the fire resistance of simply
supported reinforced solid concrete slabs. The calculated
fire resistance is compared to prescribed provisions for
slabs exposed to the standard fire and an equivalent fire
severity method for slabs exposed natural fires.
II. COMPARATIVE STUDY OF FLAT SLAB AND
CONVENTIONAL SLAB
The Flat slab building in which slab is directly supported by
columns, have been adopted in many building constructed
recently, due to the advantage of reduced floor to floor
height. Conventional slab system consists of thin beams
spaced at regular intervals in perpendicular directions,
monolithic with slab. The seismic performance of buildings
having conventional slab and flat slab is comparable but the
differences exist. Tall buildings with flat slab system are
weaker in shear whereas those with conventional floor
system are robust but taller and functionally less friendly.
Flat slab is quite common which enhances the weight
reduction, speed up construction, and economical.
Conventional slab has got features like more stiffness,
higher load carrying capacity, safe and economical also.
Conventional Reinforced Concrete (RC) frame buildings are
commonly used for the construction. The use of flat slab
building provides many advantages over conventional RC
frame building in terms of architectural flexibility, use of
space, easier formwork and shorter construction time. The
weight of flat slab structure is less compared to
conventional slab structure.
III. SEISMIC EFFECTS
Earthquakes are natural hazards due to which damage
occur to buildings and other man-made structures.
Experience has shown that for new constructions,
establishing earthquake resistant regulations and their
implementationisthecritical safeguardagainstearthquake-
induced damage. As regards existing structures, it is
necessary to evaluate and strengthen them based on
evaluation criteria before an earthquake. Earthquake
damage mainly depends on parameters such as intensity,
duration and frequency of ground motion, geologic and soil
condition, quality of construction, etc.
The April 2015 Nepal earthquake of India was an eye
opener killed over 8,000 people and injured more than
21,000. It occurred at 11:56 Nepal Standard Time , with a
magnitude of 7.8Mw or 8.1Ms and a maximum Mercalli
Intensity of IX . Its epicenter was east of Gorkha District at
Barpak, Gorkha, and its hypocenter was at a depth of
approximately 8.2 km (5.1 mi). It was the worst natural
disaster to strike Nepal since the 1934 Nepal–Bihar
earthquake.
IV. TEMPERATURE EFFECTS
With the increased incidents of major fires and fire
accidents in buildings;assessment,repairandrehabilitation
of fire damaged structures has become a topical interest.
This specialized field involves expertise in many areas like
concrete technology, material scienceandtesting,structural
engineering, repair materials and techniques etc. Research
and development efforts are being carried out in these
related disciplines. Any structure can undergofireaccident,
but because of this the structure cannot be denied neither
abandoned. To make a structure functionally viable after
the damage due to fire has become a challenge for the civil
engineering community. The problem is where to start and
how to proceed. It is vitally important that we create
buildings and structures that protect both people and
property as effectively as possible. Annual statistics on
losses caused by fires in homes and elsewhere make for
some unpleasant readings and sadly through these events
we learn more about fire safety design.
V. OBJECTIVES OF THE STUDY
A. The present work aims at the following objectives:
To investigate and compare seismic behavior of RCC flat
slab and conventional slabusingtheNon-lineartimehistory
analysis with different thickness.
To investigate and compare the effect of Temperature load
on RCC flat slab and conventional slab with different
thickness.
To investigate and compare the behavior of both structure
for the parameters like lateral displacement, inter story
drift, axial force, and bending moment.
1) Flat slab and Conventional slab models are prepared.
Models are analyzed by nonlinear time history analysis
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1372
S.no Variable Data
1. Type of structure Moment Resisting Frame
2. Seismic Data Nepal Earthquake data
3.
Number of
Stories
G+4 & G+8
4. Floor height 3m
5. Plan Dimensions 18m x 24m
6.
Total height of
Building
15m & 27m
7. Live Load 3.0 kN/m2
8. Dead load
1 kN/m2 & wall load of 10
kN/m
9. Materials
Concrete (M30) and
Reinforced with HYSD bars
(Fe500)
10. Size of Columns
460x460 mm (for 4 & 8storey
frame)
11. Size of Beams 300x460 mm
12. Depth of slab 150mm thick & 200mm thick
13. Depth of drop 150mm
14.
Specific weight of
RCC
25 kN/m3
15. Zone II
16.
Importance
Factor
1
17.
Response
Reduction Factor
5
18. Type of soil Medium
Table 1: Preliminary Data Considered in the Analysis of
the Framed Structure for Seismic Load
2) Temperature load case is also considered of 280C and
4000C.
S.no Variable Data
1 . Type of structure Moment Resisting Frame
2 . Temperature Data 280C and 4000C
3 . Number of Stories G+4,G+8
4 . Floor height 3m
5 . Plan Dimensions 18m x 24m
6 .
Total height of
buildings
15,27 & 39m
7 . Materials
Concrete (M30) and Reinforced
with HYSD bars (Fe500)
8 . Size of Columns
460x460 mm (for 4 & 8storey
frame)
9 . Size of Beams 300x460 mm
1 0 . Depth of slab 150mm & 200mm thick
1 1 . Specific weight of
RCC
25 kN/m3
Table 2: Preliminary Data Considered for Temperature
Load
VI. RESULTS & DISCUSSIONS
1) Firstly, the results for Seismic effects are obtained by
using SAP-2000 software. In this models are
generated based on the variables assumed i.e.; flat
slab with and without drop and conventional slab.
Loads are imposed and after application of loads on
the structure, analysis of the models is carried out by
using Non-Linear Time History Analysis and the
results are obtained. Therefore, values for the
respective parameters are taken and graphs are
plotted.
2) Secondly, the results obtained by carrying out analysis
based on different Temperature effects fortheFlatslab
with and without drop and conventional slab are
illustrated. In this casetemperature effectsonbuildings
are observed by Normal (280C) and High (4000C)
Temperatures.
Subsequently discussions are made for the results obtained
for lateral displacement, inter storey drift, bendingmoment,
axial force.
A. Displacement of G+4 Storey Structure with 150mm
Thickness under Seismic Load
Storey Displacement
in mm for
Conventional
Slab
Displacement
in mm for Flat
Slab without
Drop
Displacement
in mm for Flat
Slab with Drop
1 9.4 16.4 14.9
2 23.5 52.3 46
3 35.7 93.7 79.7
4 44.7 132.5 108.8
5 50 165.7 131.5
Fig. 5.1: Displacement of (3+4 Storey Structures with
150mm thickness under seismic load
B. Displacement of G+4 Storey Structures with 200mm
Thickness Under Seismic Load.
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1373
Storey
Displacement
in mm for
Conventional
Slab
Displacement
in mm for Flat
Slab without
Drop
Displacement
in mm for Flat
Slab with Drop
1 10.6 18.4 15.6
2 25.8 57.6 44.9
3 38.5 101.2 74.3
4 47.4 140.7 97.5
5 52.3 173.7 113.3
Fig. 5.2: displacement of (3+4 storey Structures with
200mm thickness under seismic load
C. Displacement of G+8 Storey Structures with 150mm
Thickness under Seismic Load
Storey
Displacement
in mm for
Conventional
Slab
Displacement
in mm for Flat
Slab without
Drop
Displacement
in mm for Flat
Slab with Drop
1 16.1 35.3 26.1
2 41.4 116.3 83.2
3 66.1 216.9 151.5
4 87.6 321.1 219.9
5 107 419.7 282.2
6 123.7 510.7 335.4
7 136.7 590.2 377.9
8 145.8 656.1 409.7
9 151 709.9 434
Fig. 5.3: displacement of (3+8 Storey Structures
with 150mm thickness under seismic load
D. Displacement of G+8 Storey Structures with 200mm
Thickness Under Seismic Load.
Displacement Displacement Displacement
Storey in mm for in mm for Flat in mm for Flat
Conventional Slab without Slab with Drop
Slab Drop
1 18.3 49.7 27.2
2 46.3 161 81.3
3 73.4 296.6 141.7
4 97.5 434.4 201.2
5 118.1 562.9 256.3
6 135.1 679.6 304.3
7 149.4 777.5 342.9
8 159.4 855.2 370.6
9 165.1 916.1 388.7
Fig. 5.4: displacement of G+8 storey Structures
with 200mm thickness under seismic load
E. Displacement of G+4 Storey Structures with 150mm
Thickness under Normal Temperature
Store
y
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and without
Drop
1 1.2 1.5
2 1.1 1.4
3 1.1 1.4
4 1.1 1.4
5 1.1 1.4
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1374
Fig. 5.25: displacement of G+4 storey Structures with
150mm thickness under normal Temperature
F. Displacement of G+4 Storey Structures with 200mm
Thickness Under Normal Temperature.
Store
y
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and without
Drop
1 1.3 1.5
2 1.2 1.4
3 1.2 1.4
4 1.2 1.4
5 1.2 1.4
G. Displacement of G+8 Storey Structures with 150mm
Thickness Under Normal Temperature.
Storey
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and
without Drop
1 1.3 1.5
2 1.2 1.4
3 1.2 1.4
4 1.2 1.4
5 1.2 1.4
6 1.2 1.4
7 1.2 1.4
8 1.2 1.4
9 1.2 1.4
H. Displacement of G+8 Storey Structures with 200mm
Thickness under Normal Temperature.
Storey
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and without
Drop
1 1.3 1.5
2 1.2 1.4
3 1.2 1.4
4 1.2 1.4
5 1.2 1.4
6 1.2 1.4
7 1.2 1.4
8 1.2 1.4
9 1.2 1.4
Fig. 5.28: displacement of G+4 storey Structures with
150mm thickness under normal Temperature
I. Displacement of G+4 Storey Structures with 150mm
Thickness under High Temperature
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1375
Stor
ey
Displacement in mm
for Conventional Slab
Displacement in mm
for Flat Slab with and
without Drop
1 16.5 19.4
2 16.9 19.9
3 16.8 19.8
4 16.8 19.8
5 16.8 19.8
Fig. 5.43 Displacement of G+4 Storey Structures with
150mm Thickness under High Temperature.
J. Displacement of G+4 Storey Structures with 200mm
Thickness under High Temperature
Store
y
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and without
Drop
1 17.2 19.5
2 17.5 19.9
3 17.4 19.8
4 17.4 19.8
5 17.4 19.8
Fig. 5.44: Displacement of G+4 Storey Structures with
200mm Thickness under High Temperature
K. Displacement of G+8 Storey Structures with 150mm
Thickness Under High Temperature
Storey
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and without
Drop
1 16.5 19.4
2 16.9 19.9
3 16.8 19.8
4 16.8 19.8
5 16.8 19.8
6 16.8 19.8
7 16.8 19.8
8 16.8 19.8
9 16.8 19.8
Fig. 5.45: Displacement of G+8 Storey Structures with
150mm Thickness under High Temperature
L. Displacement of G+8 Storey Structures with 200mm
Thickness under High Temperature.
Storey
Displacement in
mm
for Conventional
Slab
Displacement in
mm for Flat Slab
with and
without Drop
1 17.2 19.5
2 17.5 19.9
3 17.4 19.8
4 17.4 19.8
5 17.4 19.8
6 17.4 19.8
7 17.4 19.8
8 17.4 19.8
9 17.4 19.8
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072
© 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1376
Fig. 5.46: Displacement of G+8 Storey Structures with
200mm Thickness under High Temperature.
VII. RESULTS & CONCLUSIONS
Lateral displacement in column increases as the Storeylevel
increases. The lateral displacement will increase drastically
as the height increases. Lateral displacement will be
minimum at plinth level and maximum at terrace level.
Lateral displacement of conventional R.C.C Slab is less than
the flat slab buildings. About 68% to 70% of displacement is
less in conventional slab than in flat slab is observed
considering G+4 & G+8 with 150mm thickness of slab as
shown in Figures 5.1, 5.3 and Tables 5.1, 5.3
About 70% to 82% of displacement is less in conventional
slab than in flat slab is observed considering G+4&G+8 with
200mm thickness of slab as shown in Figures 5.2, 5.4 and
Tables 5.2, 5.4. It is because of the presences of beam in
conventional slab which has more stiffness compared to flat
slab. Conventional slab also has higher load carrying
capacity.
A. Conventional Slab and Flat Slab Subjected to Normal
Temperature:
When temperature load is applied to the structure, the
weight of the columns goes on increasing which makes the
lowest column bulge and at that point displacement is
maximum in the structure.
It is observed that Displacement of conventional slab of
150mm thickness is less, about 14%to21%comparedtothe
flat slabs building as shown in Figures 5.25, 5.27 and Tables
5.25, 5.27.
It is observed that 7% to 14% of Displacement of
conventional slab is less compared to Flat slabs of same
thickness 200mm as shown in Figures 5.26, 5.28 and Tables
5.26, 5.28.
Axial force in conventional slab will be more compared to
flat slabs. For 150mm thickness of slab about 76% to 80%
and for 200mm thickness of the slab 60% to 66% as shown
in Figures 5.37 to 5.42 and Tables 5.37 to 5.42.
Bending moment in conventional slab is less compare to flat
slabs. For 150mm thickness of slab about 9% to 10%and for
200mm thickness of the slab 6% to 8% as shown in Figures
5.31 to 5.36 and Tables 5.31 to 5.36.
B. Conventional Slab and Flat Slab Subjected to High
Temperature:
It is observed that Displacement of conventional of 150mm
thickness is less, about 15% compared to the flat slabs as
shown in Figures 5.43, 5.45 and Tables 5.43, 5.45
It is observed that 12% to 14% of Displacement of
conventional slab is less compared to flat slabs of same
thickness 200mm as shown in Figures 5.44, 5.46 and Tables
5.44, 5.46
Axial force in conventional slab will be more compared to
flat slabs. For 150mm thickness of slab about 76% to 80%
and for 200mm thickness of the slab 60% to 66% as shown
in Figures 5.55 to 5.60 and Tables 5.55 to 5.60. 91
Bending moment in conventional slab is less compare to flat
slabs. For 150mm thickness of slab about 9% to 10%and for
200mm thickness of the slab 6% to 8% as shown in Figures
5.49 to 5.54 and Tables 5.49 to 5.54.
REFERENCES
[1] Kang, Won, S., Hong and Gul, S. (2003). "Behavior of
Concrete Members at Elevated Temperatures
Considering InelasticDeformation." FireTechnology,39,
9–22.
[2] Levesque, A. (2006). Fire Performance of Reinforced
Concrete Slabs, Worcester Polytechnic Institute,
Massachusetts, U.S.
[3] Wang, G. G. (2006). Performance of reinforced Concrete
Flat Slabs Exposed to Fire, University of Canterbury,
Christchurch, New Zealand.
[4] Manley, D. M. (2014). "Design of Reinforced Concrete
Slabs Exposed to Natural Fires." Proc.,Conf.onFireEng.,
University ofCanterbury, Christchurch,NewZealandBIS
(Bureau of Indian Standards). (2002). “Criteria for
Earthquake Resistant Design of Structures, Part 1 –
General Provisions and Buildings.” IS 1893:2002(Part–
1), New Delhi

More Related Content

What's hot

Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...
Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...
Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...IRJET Journal
 
Case study on a fire exposed precast slab
Case study on a fire exposed precast slabCase study on a fire exposed precast slab
Case study on a fire exposed precast slabParamaAthmeka
 
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET Journal
 
Behaviour of reinforced concrete frame with in fill walls under seismic loads...
Behaviour of reinforced concrete frame with in fill walls under seismic loads...Behaviour of reinforced concrete frame with in fill walls under seismic loads...
Behaviour of reinforced concrete frame with in fill walls under seismic loads...IAEME Publication
 
IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...
IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...
IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...IRJET Journal
 
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...IRJET Journal
 
IRJET- Seismic Retrofitting
IRJET- Seismic RetrofittingIRJET- Seismic Retrofitting
IRJET- Seismic RetrofittingIRJET Journal
 
IRJET- Earthquake Analysis of RC Building with and without Infill Wall
IRJET- Earthquake Analysis of RC Building with and without Infill WallIRJET- Earthquake Analysis of RC Building with and without Infill Wall
IRJET- Earthquake Analysis of RC Building with and without Infill WallIRJET Journal
 
Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy
Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy
Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy IJERA Editor
 
Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...
Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...
Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...IRJET Journal
 
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...IRJET Journal
 
Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...
Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...
Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...IJERA Editor
 
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...IRJET Journal
 
IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...
IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...
IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...IRJET Journal
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)IJERD Editor
 
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
IRJET- Analytical Design for Optimization of Shear Wall for Flat SlabIRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
IRJET- Analytical Design for Optimization of Shear Wall for Flat SlabIRJET Journal
 
IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...
IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...
IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...IRJET Journal
 
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...IRJET Journal
 

What's hot (20)

Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...
Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...
Effect of Soil Structure Interaction on Buildings with Stiffness Irregularity...
 
Case study on a fire exposed precast slab
Case study on a fire exposed precast slabCase study on a fire exposed precast slab
Case study on a fire exposed precast slab
 
P01254123131
P01254123131P01254123131
P01254123131
 
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
IRJET- Comparative Study on CFST and Steel Diagrid Structural System for High...
 
Behaviour of reinforced concrete frame with in fill walls under seismic loads...
Behaviour of reinforced concrete frame with in fill walls under seismic loads...Behaviour of reinforced concrete frame with in fill walls under seismic loads...
Behaviour of reinforced concrete frame with in fill walls under seismic loads...
 
IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...
IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...
IRJET-Analysis and Seismic Response Reduction of Building using Base Isolatio...
 
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
IRJET- Effect of Different Soil Conditions on Seismic Response of Multi-Store...
 
IRJET- Seismic Retrofitting
IRJET- Seismic RetrofittingIRJET- Seismic Retrofitting
IRJET- Seismic Retrofitting
 
IRJET- Earthquake Analysis of RC Building with and without Infill Wall
IRJET- Earthquake Analysis of RC Building with and without Infill WallIRJET- Earthquake Analysis of RC Building with and without Infill Wall
IRJET- Earthquake Analysis of RC Building with and without Infill Wall
 
Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy
Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy
Low cycle biaxial fatigue behavior of direct aged Nickel-based 718 superalloy
 
Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...
Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...
Influence of Openings and Local Soil Conditions on the Seismic Behavior of Tu...
 
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
IRJET- Performance Study of High Rise Building with Bracing and Diagrid Struc...
 
DNV - GL 01-04-2014
DNV - GL 01-04-2014DNV - GL 01-04-2014
DNV - GL 01-04-2014
 
Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...
Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...
Dynamic Response of Rcc and Composite Structure with Brb Frame Subjected To S...
 
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
Comparative Study on Masonry Infill, Friction Dampers and Bare Frame Structur...
 
IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...
IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...
IRJET - Experimental Study on the Influence of Reinforcement Corrosion on Fir...
 
Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)Welcome to International Journal of Engineering Research and Development (IJERD)
Welcome to International Journal of Engineering Research and Development (IJERD)
 
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
IRJET- Analytical Design for Optimization of Shear Wall for Flat SlabIRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
IRJET- Analytical Design for Optimization of Shear Wall for Flat Slab
 
IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...
IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...
IRJET-Seismic Analysis of Hybrid Coupled Shear Wall System with GFRP Coupling...
 
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
Performance Based Evaluation of Conventional RC Framed Structure Compared wit...
 

Similar to Analysis and Comparison of R.C.C Conventional Slab& Flat Slab Under Seismic & Temperature Load

IRJET- Study of Literature on Seismic Response of RC Irregular Structure
IRJET-  	  Study of Literature on Seismic Response of RC Irregular StructureIRJET-  	  Study of Literature on Seismic Response of RC Irregular Structure
IRJET- Study of Literature on Seismic Response of RC Irregular StructureIRJET Journal
 
IRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat Slab
IRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat SlabIRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat Slab
IRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat SlabIRJET Journal
 
FIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINT
FIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINTFIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINT
FIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINTIRJET Journal
 
Review on Natural Draft Hyperbolic Cooling Towers
Review on Natural Draft Hyperbolic Cooling TowersReview on Natural Draft Hyperbolic Cooling Towers
Review on Natural Draft Hyperbolic Cooling TowersIRJET Journal
 
Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...
Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...
Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...IRJET Journal
 
IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...
IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...
IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...IRJET Journal
 
Seismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall StructuresSeismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall StructuresIRJET Journal
 
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...IRJET Journal
 
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...IRJET Journal
 
C12-AuthersCopy.pdf on earthquake resistance building
C12-AuthersCopy.pdf on earthquake resistance buildingC12-AuthersCopy.pdf on earthquake resistance building
C12-AuthersCopy.pdf on earthquake resistance buildingAblodeyAgbeko
 
Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...
Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...
Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...IRJET Journal
 
Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...IRJET Journal
 
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...IRJET Journal
 
A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...
A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...
A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...IRJET Journal
 
Performance of ibs precast concrete beam column connections under earthquake ...
Performance of ibs precast concrete beam column connections under earthquake ...Performance of ibs precast concrete beam column connections under earthquake ...
Performance of ibs precast concrete beam column connections under earthquake ...Ramin Vaghei
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...IRJET Journal
 
IRJET- A Performance Study of High Raise Building with Flat Slab System u...
IRJET-  	  A Performance Study of High Raise Building with Flat Slab System u...IRJET-  	  A Performance Study of High Raise Building with Flat Slab System u...
IRJET- A Performance Study of High Raise Building with Flat Slab System u...IRJET Journal
 
Seismic Analysis of Reinforced Concrete Building Using Fluid Viscous Damper
Seismic Analysis of Reinforced Concrete Building Using Fluid Viscous DamperSeismic Analysis of Reinforced Concrete Building Using Fluid Viscous Damper
Seismic Analysis of Reinforced Concrete Building Using Fluid Viscous DamperIRJET Journal
 
IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...
IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...
IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...IRJET Journal
 
IRJET- A Study on Seismic Performance of Reinforced Concrete Frame with L...
IRJET-  	  A Study on Seismic Performance of Reinforced Concrete Frame with L...IRJET-  	  A Study on Seismic Performance of Reinforced Concrete Frame with L...
IRJET- A Study on Seismic Performance of Reinforced Concrete Frame with L...IRJET Journal
 

Similar to Analysis and Comparison of R.C.C Conventional Slab& Flat Slab Under Seismic & Temperature Load (20)

IRJET- Study of Literature on Seismic Response of RC Irregular Structure
IRJET-  	  Study of Literature on Seismic Response of RC Irregular StructureIRJET-  	  Study of Literature on Seismic Response of RC Irregular Structure
IRJET- Study of Literature on Seismic Response of RC Irregular Structure
 
IRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat Slab
IRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat SlabIRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat Slab
IRJET- Effects of Thermal Loads on RCC Conventional Slab and Flat Slab
 
FIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINT
FIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINTFIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINT
FIRE RESISTANT ANALYSIS OF RC BEAM COLUMN JOINT
 
Review on Natural Draft Hyperbolic Cooling Towers
Review on Natural Draft Hyperbolic Cooling TowersReview on Natural Draft Hyperbolic Cooling Towers
Review on Natural Draft Hyperbolic Cooling Towers
 
Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...
Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...
Comparative Study of Waffle Slab and Conventional Slabs with Bracing System U...
 
IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...
IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...
IRJET- Experimental Study on Residual Characteristics of Concrete Subjected t...
 
Seismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall StructuresSeismic Performance Study on RC Wall Structures
Seismic Performance Study on RC Wall Structures
 
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
 
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
“THE SEISMIC RESISTANCE OF THE DIFFERENT INFILL MATERIALS USED IN THE CONSTRU...
 
C12-AuthersCopy.pdf on earthquake resistance building
C12-AuthersCopy.pdf on earthquake resistance buildingC12-AuthersCopy.pdf on earthquake resistance building
C12-AuthersCopy.pdf on earthquake resistance building
 
Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...
Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...
Comparative Study of Post Tensioned and RCC Flat Slab in Multi-Storey Commerc...
 
Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...Performance based seismic design of the multi-storied reinforced concrete bui...
Performance based seismic design of the multi-storied reinforced concrete bui...
 
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
 
A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...
A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...
A REVIEW ON SEISMIC PERFORMANCE OF RC BUILDING WITH LIGHTWEIGHT BRICKS AND CO...
 
Performance of ibs precast concrete beam column connections under earthquake ...
Performance of ibs precast concrete beam column connections under earthquake ...Performance of ibs precast concrete beam column connections under earthquake ...
Performance of ibs precast concrete beam column connections under earthquake ...
 
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
 
IRJET- A Performance Study of High Raise Building with Flat Slab System u...
IRJET-  	  A Performance Study of High Raise Building with Flat Slab System u...IRJET-  	  A Performance Study of High Raise Building with Flat Slab System u...
IRJET- A Performance Study of High Raise Building with Flat Slab System u...
 
Seismic Analysis of Reinforced Concrete Building Using Fluid Viscous Damper
Seismic Analysis of Reinforced Concrete Building Using Fluid Viscous DamperSeismic Analysis of Reinforced Concrete Building Using Fluid Viscous Damper
Seismic Analysis of Reinforced Concrete Building Using Fluid Viscous Damper
 
IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...
IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...
IRJET - Analysis of Flat Slab Structural System in Different Earthquake Zones...
 
IRJET- A Study on Seismic Performance of Reinforced Concrete Frame with L...
IRJET-  	  A Study on Seismic Performance of Reinforced Concrete Frame with L...IRJET-  	  A Study on Seismic Performance of Reinforced Concrete Frame with L...
IRJET- A Study on Seismic Performance of Reinforced Concrete Frame with L...
 

More from IRJET Journal

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...IRJET Journal
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTUREIRJET Journal
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...IRJET Journal
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsIRJET Journal
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...IRJET Journal
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...IRJET Journal
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...IRJET Journal
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASIRJET Journal
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...IRJET Journal
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProIRJET Journal
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...IRJET Journal
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemIRJET Journal
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesIRJET Journal
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web applicationIRJET Journal
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...IRJET Journal
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.IRJET Journal
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...IRJET Journal
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignIRJET Journal
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...IRJET Journal
 
Solving Linear Differential Equations with Constant Coefficients
Solving Linear Differential Equations with Constant CoefficientsSolving Linear Differential Equations with Constant Coefficients
Solving Linear Differential Equations with Constant CoefficientsIRJET Journal
 

More from IRJET Journal (20)

TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
 
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURESTUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
 
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
 
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil CharacteristicsEffect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
 
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
 
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
 
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
 
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADASA REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
 
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
 
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD ProP.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
 
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
 
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare SystemSurvey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
 
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridgesReview on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
 
React based fullstack edtech web application
React based fullstack edtech web applicationReact based fullstack edtech web application
React based fullstack edtech web application
 
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
 
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
 
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
 
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic DesignMultistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
 
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
 
Solving Linear Differential Equations with Constant Coefficients
Solving Linear Differential Equations with Constant CoefficientsSolving Linear Differential Equations with Constant Coefficients
Solving Linear Differential Equations with Constant Coefficients
 

Recently uploaded

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSISrknatarajan
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Christo Ananth
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesPrabhanshu Chaturvedi
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduitsrknatarajan
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTbhaskargani46
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxfenichawla
 
Vivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design SpainVivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design Spaintimesproduction05
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...ranjana rawat
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLManishPatel169454
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptDineshKumar4165
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 

Recently uploaded (20)

VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Ankleshwar 7001035870 Whatsapp Number, 24/07 Booking
 
UNIT-III FMM. DIMENSIONAL ANALYSIS
UNIT-III FMM.        DIMENSIONAL ANALYSISUNIT-III FMM.        DIMENSIONAL ANALYSIS
UNIT-III FMM. DIMENSIONAL ANALYSIS
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
 
Glass Ceramics: Processing and Properties
Glass Ceramics: Processing and PropertiesGlass Ceramics: Processing and Properties
Glass Ceramics: Processing and Properties
 
Roadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and RoutesRoadmap to Membership of RICS - Pathways and Routes
Roadmap to Membership of RICS - Pathways and Routes
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar  ≼🔝 Delhi door step de...
Call Now ≽ 9953056974 ≼🔝 Call Girls In New Ashok Nagar ≼🔝 Delhi door step de...
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
UNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular ConduitsUNIT-II FMM-Flow Through Circular Conduits
UNIT-II FMM-Flow Through Circular Conduits
 
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptxBSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
BSides Seattle 2024 - Stopping Ethan Hunt From Taking Your Data.pptx
 
Vivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design SpainVivazz, Mieres Social Housing Design Spain
Vivazz, Mieres Social Housing Design Spain
 
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Manchar 8250192130 Will You Miss This Cha...
 
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELLPVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
PVC VS. FIBERGLASS (FRP) GRAVITY SEWER - UNI BELL
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 

Analysis and Comparison of R.C.C Conventional Slab& Flat Slab Under Seismic & Temperature Load

  • 1. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1370 Analysis and Comparison of R.C.C Conventional Slab& Flat Slab Under Seismic & Temperature Load Faria Aseem1, Waseem Sohail2, Abdul Quadir3 1,2Assistant Professor, Lords Institute of Engineering & Technology, Hyderabad, India 3Sr.Structural Design Engineer, PIL Limited, Hyderabad, India --------------------------------------------------------------------------------***-------------------------------------------------------------------------------- Abstract— In today’s construction the use of flat slab has become quite common. Flat-slab building structures possesses major advantages over traditional slab-beam - column structures because of the free design of space, shorter construction time, architectural–functional and economical aspects. Flat slab construction is a developing technology in India. The conventional slab has more stiffness and higher load carrying capacity. Due to urbanization and aesthetic reasons flat slab have become quite common. Because of the absence of deep beams and shear walls, flat-slab structural system is significantly more flexible for lateral loads then traditional RC frame system. The performance of flat slab system under temperature loading is also very poor. It is necessary to analyses seismic behavior of buildings for various heights to see whatare the changes that are going to occur for the conventional RC frame building, flat slab building with and without drops. In this comparative study, the seismic behavior of R.C.C flat slab and conventional slab is evaluated by nonlinear time- history analyses with different temperature loading with the help of SAP 2000 v18 software. The main parameters evaluated in this study are lateral displacement, inter story drift, axial force, and bending moment. A total of 12 models with three different structural systems i.e., conventional slab system, flat slab system without drops and flat slab system with drops are considered. For each structural system 150mm and 200mm thickness oftheslab is taken, so we have six basic models. For each basic model G+4, G+8 stories are considered. The performance of flat slab and conventional slab has to be studied when subjected to Seismic loading due to occurrence of varying magnitudes of earthquakes having different frequencies. Thetemperature loading is being considered due to frequent occurrences of fire accidents and also due to the need for knowledge in people about fire hazards. Fire will not onlycausecasualties but also effect the structure predominantly leading to its destruction. From results it can be concluded that conventional slab of 150 mm thickness is more effective for G+4 & G+8. For normal and high temperature 150mm thickness is good for G+4, G+8. Key words: Seismic Design, Temperature Loads, Flat Slab, Conventional Slab, Non-Linear Time History I. LITERATURE REVIEW Kang et al. (2003) studied the constitutive model of concrete subjected to elevated temperature. The model is composed of four strain components: free thermal strain, mechanical strain, thermal creep strain, and transientstrain due to moisture. The thermal creep strain of concrete is derived from the modified power-law relation for steady state creep. Mathematical description on the multi-axial creep behavior of concrete is also presented. The transient strain component is made in order to consider rapid irreversible strain change of moisture diffusion and evaporation. Some applications for the proposed model are carried out by a nonlinear analysis and compared with the test results and it shows that the proposed model gives a good agreement and the influences of inelastic strain changes at elevated temperatures are very important for the structural response at elevated temperatures. Levesque (2006) presented a simplified design tool which assesses the fire performance of reinforced concrete. An Excel-based spreadsheet application was developed for thermal analysis of concrete slabs. It accounts for different aggregate types, slab thicknesses,andfireexposures.Several analyses were performed with the spreadsheet application to examine the affect slab thickness and aggregate types have on the fire performance of concrete slabs in standard and natural fires. The results were comparedwith published test data and finite element software simulations to benchmark the accuracy of the proposed tool. Furthermore, methods for the design of reinforced concrete slabs in fire conditions are presented. 11Wang (2006) studied that the membrane forces and the redistribution of bending moments in the slabs considerably affected the behavior of the slabs in fire conditions. Consequently, the fire resistance of the slabs can be enhanced if tensile membrane behavior is mobilized. This thesis uses a non-linear finite element program, SAFIR, developed at the University of Liege, Belgium, to model reinforced concrete flat slabs and one-way slabs at elevated temperatures. The slabs were modeled as 3-D shell elements in the numerical structural models. It was found that the location of the fire under flat slabs and the arrangement of reinforcing bars in flat slabs significantly affect the distribution of bending moments and membrane forces in flat slabs. It was also found that the worst scenario of fire exposure could be when the flat
  • 2. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1371 slabs are exposed to fire with a decay phase or after the fire was exhausted or extinguished. The fire resistance of flat slabs is significantly increased if tensile membrane action can be mobilized. However, the distribution of membrane forces in the slabs is nonlinear. Rizk (2010) studied the development in concrete technology over the twentieth century covering materials, structural systems, analysis and construction techniques made it possible to build concrete tall buildings such as PETRONAS towers(452m), jin Mao(421m) and bhurj Dubai (800+) Manley (2014) presented the use of prescribed solutions for fire design and has allowed engineers to simply provide an assembly of elements which meets a building codes required fire resistance without necessarily understanding or evaluating the development of a fire in a compartment, the corresponding temperatures reached and the implications of such temperatures. A process is presented which uses simple thermal and mechanical models to determine the fire resistance of simply supported reinforced solid concrete slabs. The calculated fire resistance is compared to prescribed provisions for slabs exposed to the standard fire and an equivalent fire severity method for slabs exposed natural fires. II. COMPARATIVE STUDY OF FLAT SLAB AND CONVENTIONAL SLAB The Flat slab building in which slab is directly supported by columns, have been adopted in many building constructed recently, due to the advantage of reduced floor to floor height. Conventional slab system consists of thin beams spaced at regular intervals in perpendicular directions, monolithic with slab. The seismic performance of buildings having conventional slab and flat slab is comparable but the differences exist. Tall buildings with flat slab system are weaker in shear whereas those with conventional floor system are robust but taller and functionally less friendly. Flat slab is quite common which enhances the weight reduction, speed up construction, and economical. Conventional slab has got features like more stiffness, higher load carrying capacity, safe and economical also. Conventional Reinforced Concrete (RC) frame buildings are commonly used for the construction. The use of flat slab building provides many advantages over conventional RC frame building in terms of architectural flexibility, use of space, easier formwork and shorter construction time. The weight of flat slab structure is less compared to conventional slab structure. III. SEISMIC EFFECTS Earthquakes are natural hazards due to which damage occur to buildings and other man-made structures. Experience has shown that for new constructions, establishing earthquake resistant regulations and their implementationisthecritical safeguardagainstearthquake- induced damage. As regards existing structures, it is necessary to evaluate and strengthen them based on evaluation criteria before an earthquake. Earthquake damage mainly depends on parameters such as intensity, duration and frequency of ground motion, geologic and soil condition, quality of construction, etc. The April 2015 Nepal earthquake of India was an eye opener killed over 8,000 people and injured more than 21,000. It occurred at 11:56 Nepal Standard Time , with a magnitude of 7.8Mw or 8.1Ms and a maximum Mercalli Intensity of IX . Its epicenter was east of Gorkha District at Barpak, Gorkha, and its hypocenter was at a depth of approximately 8.2 km (5.1 mi). It was the worst natural disaster to strike Nepal since the 1934 Nepal–Bihar earthquake. IV. TEMPERATURE EFFECTS With the increased incidents of major fires and fire accidents in buildings;assessment,repairandrehabilitation of fire damaged structures has become a topical interest. This specialized field involves expertise in many areas like concrete technology, material scienceandtesting,structural engineering, repair materials and techniques etc. Research and development efforts are being carried out in these related disciplines. Any structure can undergofireaccident, but because of this the structure cannot be denied neither abandoned. To make a structure functionally viable after the damage due to fire has become a challenge for the civil engineering community. The problem is where to start and how to proceed. It is vitally important that we create buildings and structures that protect both people and property as effectively as possible. Annual statistics on losses caused by fires in homes and elsewhere make for some unpleasant readings and sadly through these events we learn more about fire safety design. V. OBJECTIVES OF THE STUDY A. The present work aims at the following objectives: To investigate and compare seismic behavior of RCC flat slab and conventional slabusingtheNon-lineartimehistory analysis with different thickness. To investigate and compare the effect of Temperature load on RCC flat slab and conventional slab with different thickness. To investigate and compare the behavior of both structure for the parameters like lateral displacement, inter story drift, axial force, and bending moment. 1) Flat slab and Conventional slab models are prepared. Models are analyzed by nonlinear time history analysis
  • 3. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1372 S.no Variable Data 1. Type of structure Moment Resisting Frame 2. Seismic Data Nepal Earthquake data 3. Number of Stories G+4 & G+8 4. Floor height 3m 5. Plan Dimensions 18m x 24m 6. Total height of Building 15m & 27m 7. Live Load 3.0 kN/m2 8. Dead load 1 kN/m2 & wall load of 10 kN/m 9. Materials Concrete (M30) and Reinforced with HYSD bars (Fe500) 10. Size of Columns 460x460 mm (for 4 & 8storey frame) 11. Size of Beams 300x460 mm 12. Depth of slab 150mm thick & 200mm thick 13. Depth of drop 150mm 14. Specific weight of RCC 25 kN/m3 15. Zone II 16. Importance Factor 1 17. Response Reduction Factor 5 18. Type of soil Medium Table 1: Preliminary Data Considered in the Analysis of the Framed Structure for Seismic Load 2) Temperature load case is also considered of 280C and 4000C. S.no Variable Data 1 . Type of structure Moment Resisting Frame 2 . Temperature Data 280C and 4000C 3 . Number of Stories G+4,G+8 4 . Floor height 3m 5 . Plan Dimensions 18m x 24m 6 . Total height of buildings 15,27 & 39m 7 . Materials Concrete (M30) and Reinforced with HYSD bars (Fe500) 8 . Size of Columns 460x460 mm (for 4 & 8storey frame) 9 . Size of Beams 300x460 mm 1 0 . Depth of slab 150mm & 200mm thick 1 1 . Specific weight of RCC 25 kN/m3 Table 2: Preliminary Data Considered for Temperature Load VI. RESULTS & DISCUSSIONS 1) Firstly, the results for Seismic effects are obtained by using SAP-2000 software. In this models are generated based on the variables assumed i.e.; flat slab with and without drop and conventional slab. Loads are imposed and after application of loads on the structure, analysis of the models is carried out by using Non-Linear Time History Analysis and the results are obtained. Therefore, values for the respective parameters are taken and graphs are plotted. 2) Secondly, the results obtained by carrying out analysis based on different Temperature effects fortheFlatslab with and without drop and conventional slab are illustrated. In this casetemperature effectsonbuildings are observed by Normal (280C) and High (4000C) Temperatures. Subsequently discussions are made for the results obtained for lateral displacement, inter storey drift, bendingmoment, axial force. A. Displacement of G+4 Storey Structure with 150mm Thickness under Seismic Load Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab without Drop Displacement in mm for Flat Slab with Drop 1 9.4 16.4 14.9 2 23.5 52.3 46 3 35.7 93.7 79.7 4 44.7 132.5 108.8 5 50 165.7 131.5 Fig. 5.1: Displacement of (3+4 Storey Structures with 150mm thickness under seismic load B. Displacement of G+4 Storey Structures with 200mm Thickness Under Seismic Load.
  • 4. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1373 Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab without Drop Displacement in mm for Flat Slab with Drop 1 10.6 18.4 15.6 2 25.8 57.6 44.9 3 38.5 101.2 74.3 4 47.4 140.7 97.5 5 52.3 173.7 113.3 Fig. 5.2: displacement of (3+4 storey Structures with 200mm thickness under seismic load C. Displacement of G+8 Storey Structures with 150mm Thickness under Seismic Load Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab without Drop Displacement in mm for Flat Slab with Drop 1 16.1 35.3 26.1 2 41.4 116.3 83.2 3 66.1 216.9 151.5 4 87.6 321.1 219.9 5 107 419.7 282.2 6 123.7 510.7 335.4 7 136.7 590.2 377.9 8 145.8 656.1 409.7 9 151 709.9 434 Fig. 5.3: displacement of (3+8 Storey Structures with 150mm thickness under seismic load D. Displacement of G+8 Storey Structures with 200mm Thickness Under Seismic Load. Displacement Displacement Displacement Storey in mm for in mm for Flat in mm for Flat Conventional Slab without Slab with Drop Slab Drop 1 18.3 49.7 27.2 2 46.3 161 81.3 3 73.4 296.6 141.7 4 97.5 434.4 201.2 5 118.1 562.9 256.3 6 135.1 679.6 304.3 7 149.4 777.5 342.9 8 159.4 855.2 370.6 9 165.1 916.1 388.7 Fig. 5.4: displacement of G+8 storey Structures with 200mm thickness under seismic load E. Displacement of G+4 Storey Structures with 150mm Thickness under Normal Temperature Store y Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 1.2 1.5 2 1.1 1.4 3 1.1 1.4 4 1.1 1.4 5 1.1 1.4
  • 5. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1374 Fig. 5.25: displacement of G+4 storey Structures with 150mm thickness under normal Temperature F. Displacement of G+4 Storey Structures with 200mm Thickness Under Normal Temperature. Store y Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 1.3 1.5 2 1.2 1.4 3 1.2 1.4 4 1.2 1.4 5 1.2 1.4 G. Displacement of G+8 Storey Structures with 150mm Thickness Under Normal Temperature. Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 1.3 1.5 2 1.2 1.4 3 1.2 1.4 4 1.2 1.4 5 1.2 1.4 6 1.2 1.4 7 1.2 1.4 8 1.2 1.4 9 1.2 1.4 H. Displacement of G+8 Storey Structures with 200mm Thickness under Normal Temperature. Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 1.3 1.5 2 1.2 1.4 3 1.2 1.4 4 1.2 1.4 5 1.2 1.4 6 1.2 1.4 7 1.2 1.4 8 1.2 1.4 9 1.2 1.4 Fig. 5.28: displacement of G+4 storey Structures with 150mm thickness under normal Temperature I. Displacement of G+4 Storey Structures with 150mm Thickness under High Temperature
  • 6. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1375 Stor ey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 16.5 19.4 2 16.9 19.9 3 16.8 19.8 4 16.8 19.8 5 16.8 19.8 Fig. 5.43 Displacement of G+4 Storey Structures with 150mm Thickness under High Temperature. J. Displacement of G+4 Storey Structures with 200mm Thickness under High Temperature Store y Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 17.2 19.5 2 17.5 19.9 3 17.4 19.8 4 17.4 19.8 5 17.4 19.8 Fig. 5.44: Displacement of G+4 Storey Structures with 200mm Thickness under High Temperature K. Displacement of G+8 Storey Structures with 150mm Thickness Under High Temperature Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 16.5 19.4 2 16.9 19.9 3 16.8 19.8 4 16.8 19.8 5 16.8 19.8 6 16.8 19.8 7 16.8 19.8 8 16.8 19.8 9 16.8 19.8 Fig. 5.45: Displacement of G+8 Storey Structures with 150mm Thickness under High Temperature L. Displacement of G+8 Storey Structures with 200mm Thickness under High Temperature. Storey Displacement in mm for Conventional Slab Displacement in mm for Flat Slab with and without Drop 1 17.2 19.5 2 17.5 19.9 3 17.4 19.8 4 17.4 19.8 5 17.4 19.8 6 17.4 19.8 7 17.4 19.8 8 17.4 19.8 9 17.4 19.8
  • 7. International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 04 Issue: 10 | Oct -2017 www.irjet.net p-ISSN: 2395-0072 © 2017, IRJET | Impact Factor value: 6.171 | ISO 9001:2008 Certified Journal | Page 1376 Fig. 5.46: Displacement of G+8 Storey Structures with 200mm Thickness under High Temperature. VII. RESULTS & CONCLUSIONS Lateral displacement in column increases as the Storeylevel increases. The lateral displacement will increase drastically as the height increases. Lateral displacement will be minimum at plinth level and maximum at terrace level. Lateral displacement of conventional R.C.C Slab is less than the flat slab buildings. About 68% to 70% of displacement is less in conventional slab than in flat slab is observed considering G+4 & G+8 with 150mm thickness of slab as shown in Figures 5.1, 5.3 and Tables 5.1, 5.3 About 70% to 82% of displacement is less in conventional slab than in flat slab is observed considering G+4&G+8 with 200mm thickness of slab as shown in Figures 5.2, 5.4 and Tables 5.2, 5.4. It is because of the presences of beam in conventional slab which has more stiffness compared to flat slab. Conventional slab also has higher load carrying capacity. A. Conventional Slab and Flat Slab Subjected to Normal Temperature: When temperature load is applied to the structure, the weight of the columns goes on increasing which makes the lowest column bulge and at that point displacement is maximum in the structure. It is observed that Displacement of conventional slab of 150mm thickness is less, about 14%to21%comparedtothe flat slabs building as shown in Figures 5.25, 5.27 and Tables 5.25, 5.27. It is observed that 7% to 14% of Displacement of conventional slab is less compared to Flat slabs of same thickness 200mm as shown in Figures 5.26, 5.28 and Tables 5.26, 5.28. Axial force in conventional slab will be more compared to flat slabs. For 150mm thickness of slab about 76% to 80% and for 200mm thickness of the slab 60% to 66% as shown in Figures 5.37 to 5.42 and Tables 5.37 to 5.42. Bending moment in conventional slab is less compare to flat slabs. For 150mm thickness of slab about 9% to 10%and for 200mm thickness of the slab 6% to 8% as shown in Figures 5.31 to 5.36 and Tables 5.31 to 5.36. B. Conventional Slab and Flat Slab Subjected to High Temperature: It is observed that Displacement of conventional of 150mm thickness is less, about 15% compared to the flat slabs as shown in Figures 5.43, 5.45 and Tables 5.43, 5.45 It is observed that 12% to 14% of Displacement of conventional slab is less compared to flat slabs of same thickness 200mm as shown in Figures 5.44, 5.46 and Tables 5.44, 5.46 Axial force in conventional slab will be more compared to flat slabs. For 150mm thickness of slab about 76% to 80% and for 200mm thickness of the slab 60% to 66% as shown in Figures 5.55 to 5.60 and Tables 5.55 to 5.60. 91 Bending moment in conventional slab is less compare to flat slabs. For 150mm thickness of slab about 9% to 10%and for 200mm thickness of the slab 6% to 8% as shown in Figures 5.49 to 5.54 and Tables 5.49 to 5.54. REFERENCES [1] Kang, Won, S., Hong and Gul, S. (2003). "Behavior of Concrete Members at Elevated Temperatures Considering InelasticDeformation." FireTechnology,39, 9–22. [2] Levesque, A. (2006). Fire Performance of Reinforced Concrete Slabs, Worcester Polytechnic Institute, Massachusetts, U.S. [3] Wang, G. G. (2006). Performance of reinforced Concrete Flat Slabs Exposed to Fire, University of Canterbury, Christchurch, New Zealand. [4] Manley, D. M. (2014). "Design of Reinforced Concrete Slabs Exposed to Natural Fires." Proc.,Conf.onFireEng., University ofCanterbury, Christchurch,NewZealandBIS (Bureau of Indian Standards). (2002). “Criteria for Earthquake Resistant Design of Structures, Part 1 – General Provisions and Buildings.” IS 1893:2002(Part– 1), New Delhi