1. INTRODUCTION
The objective of this experiment is to calibrate the venturi and orifice meter. This also
includes comparing the two apparatus by plotting their coefficient of discharge with Reynolds
number. These devices estimate the fluid flow velocity by the use of pressure drop principle. The
coefficient of discharge is measured using the pressure drop. This allows the students to compare
the obtained data from that of the standard. The experiment assumes the fluid to be incompressible.
In industry, when controlling the production rate, flow rates must be measured. If not,
turbulent flow rates may cause unfinished mixing or laminar flows may slow the production.
Venturi and orifice both provides ease of reading of these kinds of factor.
2. THEORITICAL BACKGROUND
Venturi Meter
A venturi meter is a device that is usually used to measure the flow of a fluid in the pipe.
A Venturi meter may also be used to increase the velocity of any type fluid in a pipe at any
particular point. It basically works on the principle of Bernoulli's Theorem. The pressure in a fluid
moving through a small cross section drops suddenly leading to an increase in velocity of the flow.
The fluid of the characteristics of high pressure and low velocity gets converted to the low pressure
and high velocity at a particular point and again reaches to high pressure and low velocity. The
point where the characteristics become low pressure and high velocity is the place where the
venturi flow meter is used.
2
The Venturi meter is constructed as shown in Figure 1.1. It has a constriction within itself.
The pressure difference between the upstream and the downstream flow, Δh, can be found as a
function of the flow rate. Applying Bernoulli’s equation to points 1 and 2 of the Venturi meter and
relating the pressure difference to the flow rate yields. The discharge coefficient of a Venturi meter
is typically 0.985 but may be even higher if the convergent section is machined.
Figure 1.1
The Orifice Meter
The orifice meter consists of a throttling device (an orifice plate) inserted in the flow. This
orifice plate creates a measurable pressure difference between its upstream and downstream sides.
This pressure is then related to the flow rate. Like the Venturi meter, the pressure difference varies
directly with the flow rate. Figure 1.2 describes the basic components of an Orifice meter.
3
Figure 1.2
Bernoulli’s Principle
Both devices are based on Bernoulli’s Principle
Assuming a horizontal flow (neglecting the minor elevation difference between the
measuring points) the Bernoulli Equation can be modified to:
p1 + 1/2 ρ v1
2
= p2 + 1/2 ρ v2
2
Equation (1)
Assuming uniform velocity profiles in the upstream and downstream flow - the Continuity
Equation can be expressed as
q = v1 A1 = v2 A2
Equation (2)
Combining (1) and (2), assuming A2 < A1, gives the "ideal" equation:
4
q = A2 [ 2(p1 - p2) / ρ(1 - (A2 / A1)2
) ]1/2
Equation (3)
For a given geometry (A), the flow rate can be determined by measuring the pressure
difference p1 - p2.
Equation (3) can be modified with diameters to:
q = cd (π / 4) D2
2
[ 2 (p1 - p2) / ρ (1 - d4
) ]1/2
Equation (4)
where
D2 = orifice, venturi or nozzle inside diameter (m, in)
D1 = upstream and downstream pipe diameter (m, in)
d = D2 / D1 diameter ratio
The coefficient of discharge, Cv (for venturi) and Co (for orifice), can be calculated using
the following equation
C = Qactual/ Qtheoritica
(Equation 5)
5
When measuring the mass flow in gases, its necessary to considerate the pressure reduction
and change in density of the fluid. The formula above can be used with limitations for applications
with relatively small changes in pressure and density.
Although both uses the same principles, there are some differences of these apparatus:
• A venturi meter can be used to measure the flow rates of all incompressible
fluids (gases with low pressure variations, as wells as liquids), whereas an
orifice meter is generally used for measuring the flow rate of liquid.
• Venturi meters are only installed in pipelines, and the accelerated flow through
the apparatus is subsequently decelerated to the original velocity at the outlet
of the venturi meter. The flow continues through the pipe line. In the orifice
meter, the entire potential energy of the fluid is converted into kinetic energy,
and the jet discharges freely into the open atmosphere.
C. Because venturi is theoretically has lesser pressure loss, then it is assumed to have
a greater coefficient of discharge than that of the orifice.
6
3. MATERIALS AND METHODS
3.1 Materials
Hydraulic Bench Apparatus
Orifice meter, Venturi meter
Stopwatch
Water
Caliper
Manometer
3.1.1 Specifications for the apparatus
Orifice meter – D1- 26.6mm D2 – 13.0mm
Venturi meter – D1 – 26.6mm D2- 20mm
3.2 Methods
Materials and apparatus were checked and prepared before the experiment started
and were also cleaned appropriately. For the calibration of venture meter/ orifice meter
apparatus, the venturi or orifice meter apparatus was set up. The diameter of both apparatus
was recorded for the purpose of computation. The pump was started and the main
regulating flow valve was opened to fix the water flow rate. The tubes from the venture or
orifice pressure tapping points to the manometer (mouth or inlet tap point and throat tap
point) were connected. It was ensured that there is no trapped air in the connecting lines.
Ample time was allowed to stabilize the flow before readings were taken. The upstream
7
and downstream of the manometer were read and recorded. The theoretical volumetric flow
rate was computed. For any reading of the manometer, the volume discharged was
collected at the outlet and the time to collect the volume discharged at the outlet was
measured using a graduated cylinder. The volume collected and the time was recorded. The
actual volumetric flow rate from the volume collected divided by the time obtained was
computed. A total of ten (10) trials were taken by adjusting the main flow regulating valve.
All the data were recorded and the coefficient of discharge of the Venturi and Orifice
apparatus and their Reynolds Number were computed respectively
8
4. RESULTS AND DISCUSSION
4.1 Results
A. Orifice meter
Figure 4.1.1 Coefficient of discharge vs. Reynolds number for orifice meter
B. Venturi meter
Figure 4.1.2 Coefficient of discharge vs. Reynolds number for orifice meter
y = 80571x - 38286
0
5000
10000
15000
20000
25000
30000
0.69 0.7 0.71 0.72 0.73 0.74 0.75 0.76 0.77 0.78 0.79 0.8
ReynoldsNo.
C
0
2000
4000
6000
8000
10000
12000
14000
16000
0 0.1 0.2 0.3 0.4 0.5
REynoldsNo.
C
9
4.2 Discussion
In orifice meters, the C and Reynolds number is direct proportional as shown in
figure 4.1. On the other hand, the relationship of C and Reynolds number is inversely
proportional, as shown in Figure 4.2
From the tables 4.1.1 and 4.1.2 (appendix) it is confirmed that the pressure drop in orifice
meter is greater than that of the venturi meter.
As observed also, the flow of the water in the venturi and orifice meter are turbulent. This
is because the equipment needed more speed to avoid bubbles from getting into the tubes.
Also it is observed that Reynolds number of smaller compared to that of orifice because
venturi meter provide smooth flow than that of orifice.
10
5. CONCLUSION
In orifice meters, the C and Reynolds number is direct proportional. On the other hand, the
relationship of C and Reynolds number is inversely proportional. The tables also show a greater
discharge as the pressure drop increases. This supports the Bernoulli’s principle but however there
are errors in the experiment. The errors of the experiment may lie on the flow rates. The flow is
not very consistent. This causes the graph to be distorted a little. Overall the objectives of the
experiment were met and the students learned the characteristics of both apparatus. The experiment
gives knowledge to the student since both apparatus is commonly used in the industry.
6. RECOMMENDATION
In manipulating both devices, it is recommended to let the flow of water to above 70 cm to
avoid bubbles from getting in the tube. For ease, valves must be labeled according to the beginners’
view to avoid confusion. Also, the diameter of the pipe must be shown in the specification.
11
7. APPENDICES
Trial Manometer Reading Rm(cm) Volumetric
flowrate Q
(x10-5
m3/s)
Coefficient
of discharge
Reynolds
NumberUpstream
(cm)
Downstream
(cm)
1 71.75 73.5 1.75 5.65 0.703784643
17913.35385
2 73 75 2 6.0 0.72268771
18525.45246
3 77.25 79.5 2.25 6.3 0.715424333
19649.20959
4 74 76.5 2.5 6.25 0.673324519
20712.08551
5 81.5 84.4 2.9 7.12 0.712189246
22307.59879
6 80.5 83.5 3.0 7.0 0.688417385
22688.95289
7 79.5 82.5 3 7.5 0.737590055
22688.95289
8 87 90 3 7.79 0.766110204
22688.95289
9 88.4 92 3.6 8.0 0.718212821
24854.50261
10 93.6 97.4 3.8 9.0 0.786439155
25535.57399
Table 4.1.1: Data from Orifice Meter
12
Trial Manometer Reading Rm(cm) Volumetric
flowrate Q
(x10-5
m3/s)
Coefficient
of
discharge
Reynolds
number
Upstream Downstream
1 72 71.8 0.2 4.5
0.59612302 7131.102413
2 88 88.3 0.3 6.6
0.7138742 8733.781108
3 72.4 72.4 0.4 4.6
0.4308898 10084.90175
4 88.5 88.9 0.4 6.5
0.60886602 10084.90175
5 72.4 72.8 0.5 4
0.33513005 11275.26293
6 84.5 85 0.5 5.88
0.49264117 11275.26293
7 67 67.5 0.5 3.4
0.28486054 11275.26293
8 62 62.5 0.5 3.9
0.3267518 11275.26293
9 84.5 85 0.5 5.7
0.47756032 11275.26293
10 63 63.7 0.7 3.22
0.22800545 13341.07101
Table 4.1.2: Data from venturi Meter
13
8. REFERENCES
https://www.quora.com/What-is-the-difference-between-venturimeter-and-orificemeter
https://www.mecholic.com/2016/11/venturi-meter-construction-working-equation-application-
advantages.html
http://www.thermopedia.com/content/1241/
https://www.slideshare.net/HirizzaJunkoYamamoto/calibration-of-venturi-and-orifice-meters
https://www.slideshare.net/HirizzaJunkoYamamoto/calibration-of-venturi-and-orifice-meters
https://www.engineeringtoolbox.com/orifice-nozzle-venturi-d_590.html

More Related Content

What's hot

Head losses
Head lossesHead losses
Head losses
Faizan Shabbir
 

What's hot (20)

Flow Through Orifices - Hydraulics
Flow Through Orifices - HydraulicsFlow Through Orifices - Hydraulics
Flow Through Orifices - Hydraulics
 
VENTURIMETER -Application of Bernoulli's Law
VENTURIMETER -Application of Bernoulli's LawVENTURIMETER -Application of Bernoulli's Law
VENTURIMETER -Application of Bernoulli's Law
 
Venturi meter
Venturi meterVenturi meter
Venturi meter
 
Head losses
Head lossesHead losses
Head losses
 
Calibration of Venturi and Orifice Meters
Calibration of Venturi and Orifice MetersCalibration of Venturi and Orifice Meters
Calibration of Venturi and Orifice Meters
 
Flow through pipes
Flow through pipesFlow through pipes
Flow through pipes
 
Presentation on notches and weirs
Presentation on notches and weirsPresentation on notches and weirs
Presentation on notches and weirs
 
Notches and weir
Notches and weirNotches and weir
Notches and weir
 
Pipe sizing
Pipe sizingPipe sizing
Pipe sizing
 
Flow Measuring Device
Flow  Measuring Device Flow  Measuring Device
Flow Measuring Device
 
Flow meters
Flow metersFlow meters
Flow meters
 
Fluid mechanics
Fluid mechanicsFluid mechanics
Fluid mechanics
 
Flow measurement
Flow measurementFlow measurement
Flow measurement
 
Dymanics of open channel flow
Dymanics of open channel flowDymanics of open channel flow
Dymanics of open channel flow
 
Losses in Pipe
Losses in PipeLosses in Pipe
Losses in Pipe
 
Flow through pipes ppt
Flow through pipes pptFlow through pipes ppt
Flow through pipes ppt
 
Notches and weir
Notches and weirNotches and weir
Notches and weir
 
Pressure Measurement Part I
Pressure Measurement   Part IPressure Measurement   Part I
Pressure Measurement Part I
 
flow through venturimeter
flow through venturimeterflow through venturimeter
flow through venturimeter
 
Flow through orifice meter
Flow through orifice meterFlow through orifice meter
Flow through orifice meter
 

Similar to Venturi and orificemeter - Ed Ryan Ruales

Lab 2 Fluid Flow Rate.pdfMEE 491 Lab #2 Fluid Flow Rate .docx
Lab 2 Fluid Flow Rate.pdfMEE 491 Lab #2  Fluid Flow Rate .docxLab 2 Fluid Flow Rate.pdfMEE 491 Lab #2  Fluid Flow Rate .docx
Lab 2 Fluid Flow Rate.pdfMEE 491 Lab #2 Fluid Flow Rate .docx
DIPESH30
 
MANUALS FOR FLUID MECHANICS LAB.pdf
MANUALS FOR FLUID MECHANICS LAB.pdfMANUALS FOR FLUID MECHANICS LAB.pdf
MANUALS FOR FLUID MECHANICS LAB.pdf
amgothusandeep
 
Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
   Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx   Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
joyjonna282
 

Similar to Venturi and orificemeter - Ed Ryan Ruales (20)

flow_and_pressure.pdf
flow_and_pressure.pdfflow_and_pressure.pdf
flow_and_pressure.pdf
 
FLOW(NEW).pptx .
FLOW(NEW).pptx                          .FLOW(NEW).pptx                          .
FLOW(NEW).pptx .
 
Design & analysis of laminar flow meter
Design & analysis of laminar flow meterDesign & analysis of laminar flow meter
Design & analysis of laminar flow meter
 
exp.9 flow meter demonstration
exp.9 flow meter demonstrationexp.9 flow meter demonstration
exp.9 flow meter demonstration
 
IRJET- Experimental Study on Flow through Venturimeter
IRJET- Experimental Study on Flow through VenturimeterIRJET- Experimental Study on Flow through Venturimeter
IRJET- Experimental Study on Flow through Venturimeter
 
Lab 2 Fluid Flow Rate.pdfMEE 491 Lab #2 Fluid Flow Rate .docx
Lab 2 Fluid Flow Rate.pdfMEE 491 Lab #2  Fluid Flow Rate .docxLab 2 Fluid Flow Rate.pdfMEE 491 Lab #2  Fluid Flow Rate .docx
Lab 2 Fluid Flow Rate.pdfMEE 491 Lab #2 Fluid Flow Rate .docx
 
T2
T2T2
T2
 
- VENTURI METER .docx
- VENTURI METER .docx- VENTURI METER .docx
- VENTURI METER .docx
 
Flow visualization
Flow visualizationFlow visualization
Flow visualization
 
d351798x012_11.pdf
d351798x012_11.pdfd351798x012_11.pdf
d351798x012_11.pdf
 
Mecanica de fluidos exa 1
Mecanica de fluidos exa 1Mecanica de fluidos exa 1
Mecanica de fluidos exa 1
 
Iocl
IoclIocl
Iocl
 
pipe friction for turbulent
pipe friction for turbulentpipe friction for turbulent
pipe friction for turbulent
 
MANUALS FOR FLUID MECHANICS LAB.pdf
MANUALS FOR FLUID MECHANICS LAB.pdfMANUALS FOR FLUID MECHANICS LAB.pdf
MANUALS FOR FLUID MECHANICS LAB.pdf
 
Airflow measurement
Airflow measurement Airflow measurement
Airflow measurement
 
pipe friction for turbulent
pipe friction for turbulentpipe friction for turbulent
pipe friction for turbulent
 
Hydraulic Principles & Applications
Hydraulic Principles & ApplicationsHydraulic Principles & Applications
Hydraulic Principles & Applications
 
Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
   Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx   Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
 
ROLE OF CONTROL AND INSTRUMENTATION IN THERMAL POWER PLANT
ROLE OF CONTROL AND INSTRUMENTATION IN THERMAL POWER PLANTROLE OF CONTROL AND INSTRUMENTATION IN THERMAL POWER PLANT
ROLE OF CONTROL AND INSTRUMENTATION IN THERMAL POWER PLANT
 
Final report
Final reportFinal report
Final report
 

More from Ed Ryan Ruales (9)

Calculation guidelines for Rotary Dryer.pdf
Calculation guidelines for Rotary Dryer.pdfCalculation guidelines for Rotary Dryer.pdf
Calculation guidelines for Rotary Dryer.pdf
 
SOLICITATION.docx
SOLICITATION.docxSOLICITATION.docx
SOLICITATION.docx
 
Sieving- Ed Ryan Ruales
Sieving- Ed Ryan RualesSieving- Ed Ryan Ruales
Sieving- Ed Ryan Ruales
 
Sedimentation Ed Ryan M. Ruales
Sedimentation   Ed Ryan M. RualesSedimentation   Ed Ryan M. Ruales
Sedimentation Ed Ryan M. Ruales
 
Reynolds number - Ed Ryan M. Ruales
Reynolds number - Ed Ryan M. RualesReynolds number - Ed Ryan M. Ruales
Reynolds number - Ed Ryan M. Ruales
 
Press and frame filter- Ed Ryan M. Ruales
Press and frame filter-  Ed Ryan M. RualesPress and frame filter-  Ed Ryan M. Ruales
Press and frame filter- Ed Ryan M. Ruales
 
Heat loss in Bare and Lagged Pipes- Ed Ryan M. Ruales
Heat loss in Bare and Lagged Pipes- Ed Ryan M. RualesHeat loss in Bare and Lagged Pipes- Ed Ryan M. Ruales
Heat loss in Bare and Lagged Pipes- Ed Ryan M. Ruales
 
Fluidization -Ed Ryan M. Ruales
Fluidization -Ed Ryan M. RualesFluidization -Ed Ryan M. Ruales
Fluidization -Ed Ryan M. Ruales
 
Agitation Ed Ryan Ruales
Agitation   Ed Ryan RualesAgitation   Ed Ryan Ruales
Agitation Ed Ryan Ruales
 

Recently uploaded

Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
jaanualu31
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
pritamlangde
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
Neometrix_Engineering_Pvt_Ltd
 
Query optimization and processing for advanced database systems
Query optimization and processing for advanced database systemsQuery optimization and processing for advanced database systems
Query optimization and processing for advanced database systems
meharikiros2
 

Recently uploaded (20)

Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth Reinforcement
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
Linux Systems Programming: Inter Process Communication (IPC) using Pipes
Linux Systems Programming: Inter Process Communication (IPC) using PipesLinux Systems Programming: Inter Process Communication (IPC) using Pipes
Linux Systems Programming: Inter Process Communication (IPC) using Pipes
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
Digital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptxDigital Communication Essentials: DPCM, DM, and ADM .pptx
Digital Communication Essentials: DPCM, DM, and ADM .pptx
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Memory Interfacing of 8086 with DMA 8257
Memory Interfacing of 8086 with DMA 8257Memory Interfacing of 8086 with DMA 8257
Memory Interfacing of 8086 with DMA 8257
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Computer Networks Basics of Network Devices
Computer Networks  Basics of Network DevicesComputer Networks  Basics of Network Devices
Computer Networks Basics of Network Devices
 
Integrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - NeometrixIntegrated Test Rig For HTFE-25 - Neometrix
Integrated Test Rig For HTFE-25 - Neometrix
 
Worksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxWorksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptx
 
Electromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptxElectromagnetic relays used for power system .pptx
Electromagnetic relays used for power system .pptx
 
Query optimization and processing for advanced database systems
Query optimization and processing for advanced database systemsQuery optimization and processing for advanced database systems
Query optimization and processing for advanced database systems
 
Computer Graphics Introduction To Curves
Computer Graphics Introduction To CurvesComputer Graphics Introduction To Curves
Computer Graphics Introduction To Curves
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...Max. shear stress theory-Maximum Shear Stress Theory ​  Maximum Distortional ...
Max. shear stress theory-Maximum Shear Stress Theory ​ Maximum Distortional ...
 

Venturi and orificemeter - Ed Ryan Ruales

  • 1. 1 1. INTRODUCTION The objective of this experiment is to calibrate the venturi and orifice meter. This also includes comparing the two apparatus by plotting their coefficient of discharge with Reynolds number. These devices estimate the fluid flow velocity by the use of pressure drop principle. The coefficient of discharge is measured using the pressure drop. This allows the students to compare the obtained data from that of the standard. The experiment assumes the fluid to be incompressible. In industry, when controlling the production rate, flow rates must be measured. If not, turbulent flow rates may cause unfinished mixing or laminar flows may slow the production. Venturi and orifice both provides ease of reading of these kinds of factor. 2. THEORITICAL BACKGROUND Venturi Meter A venturi meter is a device that is usually used to measure the flow of a fluid in the pipe. A Venturi meter may also be used to increase the velocity of any type fluid in a pipe at any particular point. It basically works on the principle of Bernoulli's Theorem. The pressure in a fluid moving through a small cross section drops suddenly leading to an increase in velocity of the flow. The fluid of the characteristics of high pressure and low velocity gets converted to the low pressure and high velocity at a particular point and again reaches to high pressure and low velocity. The point where the characteristics become low pressure and high velocity is the place where the venturi flow meter is used.
  • 2. 2 The Venturi meter is constructed as shown in Figure 1.1. It has a constriction within itself. The pressure difference between the upstream and the downstream flow, Δh, can be found as a function of the flow rate. Applying Bernoulli’s equation to points 1 and 2 of the Venturi meter and relating the pressure difference to the flow rate yields. The discharge coefficient of a Venturi meter is typically 0.985 but may be even higher if the convergent section is machined. Figure 1.1 The Orifice Meter The orifice meter consists of a throttling device (an orifice plate) inserted in the flow. This orifice plate creates a measurable pressure difference between its upstream and downstream sides. This pressure is then related to the flow rate. Like the Venturi meter, the pressure difference varies directly with the flow rate. Figure 1.2 describes the basic components of an Orifice meter.
  • 3. 3 Figure 1.2 Bernoulli’s Principle Both devices are based on Bernoulli’s Principle Assuming a horizontal flow (neglecting the minor elevation difference between the measuring points) the Bernoulli Equation can be modified to: p1 + 1/2 ρ v1 2 = p2 + 1/2 ρ v2 2 Equation (1) Assuming uniform velocity profiles in the upstream and downstream flow - the Continuity Equation can be expressed as q = v1 A1 = v2 A2 Equation (2) Combining (1) and (2), assuming A2 < A1, gives the "ideal" equation:
  • 4. 4 q = A2 [ 2(p1 - p2) / ρ(1 - (A2 / A1)2 ) ]1/2 Equation (3) For a given geometry (A), the flow rate can be determined by measuring the pressure difference p1 - p2. Equation (3) can be modified with diameters to: q = cd (π / 4) D2 2 [ 2 (p1 - p2) / ρ (1 - d4 ) ]1/2 Equation (4) where D2 = orifice, venturi or nozzle inside diameter (m, in) D1 = upstream and downstream pipe diameter (m, in) d = D2 / D1 diameter ratio The coefficient of discharge, Cv (for venturi) and Co (for orifice), can be calculated using the following equation C = Qactual/ Qtheoritica (Equation 5)
  • 5. 5 When measuring the mass flow in gases, its necessary to considerate the pressure reduction and change in density of the fluid. The formula above can be used with limitations for applications with relatively small changes in pressure and density. Although both uses the same principles, there are some differences of these apparatus: • A venturi meter can be used to measure the flow rates of all incompressible fluids (gases with low pressure variations, as wells as liquids), whereas an orifice meter is generally used for measuring the flow rate of liquid. • Venturi meters are only installed in pipelines, and the accelerated flow through the apparatus is subsequently decelerated to the original velocity at the outlet of the venturi meter. The flow continues through the pipe line. In the orifice meter, the entire potential energy of the fluid is converted into kinetic energy, and the jet discharges freely into the open atmosphere. C. Because venturi is theoretically has lesser pressure loss, then it is assumed to have a greater coefficient of discharge than that of the orifice.
  • 6. 6 3. MATERIALS AND METHODS 3.1 Materials Hydraulic Bench Apparatus Orifice meter, Venturi meter Stopwatch Water Caliper Manometer 3.1.1 Specifications for the apparatus Orifice meter – D1- 26.6mm D2 – 13.0mm Venturi meter – D1 – 26.6mm D2- 20mm 3.2 Methods Materials and apparatus were checked and prepared before the experiment started and were also cleaned appropriately. For the calibration of venture meter/ orifice meter apparatus, the venturi or orifice meter apparatus was set up. The diameter of both apparatus was recorded for the purpose of computation. The pump was started and the main regulating flow valve was opened to fix the water flow rate. The tubes from the venture or orifice pressure tapping points to the manometer (mouth or inlet tap point and throat tap point) were connected. It was ensured that there is no trapped air in the connecting lines. Ample time was allowed to stabilize the flow before readings were taken. The upstream
  • 7. 7 and downstream of the manometer were read and recorded. The theoretical volumetric flow rate was computed. For any reading of the manometer, the volume discharged was collected at the outlet and the time to collect the volume discharged at the outlet was measured using a graduated cylinder. The volume collected and the time was recorded. The actual volumetric flow rate from the volume collected divided by the time obtained was computed. A total of ten (10) trials were taken by adjusting the main flow regulating valve. All the data were recorded and the coefficient of discharge of the Venturi and Orifice apparatus and their Reynolds Number were computed respectively
  • 8. 8 4. RESULTS AND DISCUSSION 4.1 Results A. Orifice meter Figure 4.1.1 Coefficient of discharge vs. Reynolds number for orifice meter B. Venturi meter Figure 4.1.2 Coefficient of discharge vs. Reynolds number for orifice meter y = 80571x - 38286 0 5000 10000 15000 20000 25000 30000 0.69 0.7 0.71 0.72 0.73 0.74 0.75 0.76 0.77 0.78 0.79 0.8 ReynoldsNo. C 0 2000 4000 6000 8000 10000 12000 14000 16000 0 0.1 0.2 0.3 0.4 0.5 REynoldsNo. C
  • 9. 9 4.2 Discussion In orifice meters, the C and Reynolds number is direct proportional as shown in figure 4.1. On the other hand, the relationship of C and Reynolds number is inversely proportional, as shown in Figure 4.2 From the tables 4.1.1 and 4.1.2 (appendix) it is confirmed that the pressure drop in orifice meter is greater than that of the venturi meter. As observed also, the flow of the water in the venturi and orifice meter are turbulent. This is because the equipment needed more speed to avoid bubbles from getting into the tubes. Also it is observed that Reynolds number of smaller compared to that of orifice because venturi meter provide smooth flow than that of orifice.
  • 10. 10 5. CONCLUSION In orifice meters, the C and Reynolds number is direct proportional. On the other hand, the relationship of C and Reynolds number is inversely proportional. The tables also show a greater discharge as the pressure drop increases. This supports the Bernoulli’s principle but however there are errors in the experiment. The errors of the experiment may lie on the flow rates. The flow is not very consistent. This causes the graph to be distorted a little. Overall the objectives of the experiment were met and the students learned the characteristics of both apparatus. The experiment gives knowledge to the student since both apparatus is commonly used in the industry. 6. RECOMMENDATION In manipulating both devices, it is recommended to let the flow of water to above 70 cm to avoid bubbles from getting in the tube. For ease, valves must be labeled according to the beginners’ view to avoid confusion. Also, the diameter of the pipe must be shown in the specification.
  • 11. 11 7. APPENDICES Trial Manometer Reading Rm(cm) Volumetric flowrate Q (x10-5 m3/s) Coefficient of discharge Reynolds NumberUpstream (cm) Downstream (cm) 1 71.75 73.5 1.75 5.65 0.703784643 17913.35385 2 73 75 2 6.0 0.72268771 18525.45246 3 77.25 79.5 2.25 6.3 0.715424333 19649.20959 4 74 76.5 2.5 6.25 0.673324519 20712.08551 5 81.5 84.4 2.9 7.12 0.712189246 22307.59879 6 80.5 83.5 3.0 7.0 0.688417385 22688.95289 7 79.5 82.5 3 7.5 0.737590055 22688.95289 8 87 90 3 7.79 0.766110204 22688.95289 9 88.4 92 3.6 8.0 0.718212821 24854.50261 10 93.6 97.4 3.8 9.0 0.786439155 25535.57399 Table 4.1.1: Data from Orifice Meter
  • 12. 12 Trial Manometer Reading Rm(cm) Volumetric flowrate Q (x10-5 m3/s) Coefficient of discharge Reynolds number Upstream Downstream 1 72 71.8 0.2 4.5 0.59612302 7131.102413 2 88 88.3 0.3 6.6 0.7138742 8733.781108 3 72.4 72.4 0.4 4.6 0.4308898 10084.90175 4 88.5 88.9 0.4 6.5 0.60886602 10084.90175 5 72.4 72.8 0.5 4 0.33513005 11275.26293 6 84.5 85 0.5 5.88 0.49264117 11275.26293 7 67 67.5 0.5 3.4 0.28486054 11275.26293 8 62 62.5 0.5 3.9 0.3267518 11275.26293 9 84.5 85 0.5 5.7 0.47756032 11275.26293 10 63 63.7 0.7 3.22 0.22800545 13341.07101 Table 4.1.2: Data from venturi Meter