PLATFORM
SWITCHING
Shari S. R
2
PARTS OF AN IMPLANT RESTORATION
Abutment
Crown
Titanium Implant
Fitted over the Abutment
for a natural appearance.
Fitted over the portion of
implant that protrudes
from the gum line
Surgically fused with the
jawbone.
PLATFORM SWITCHING
SWITCHING
3
CONTENTS
 CONCEPT
 HISTORY
 CRESTAL BONE LOSS
 REDUCING CRESTAL BONE LOSS
 ADVANTAGES
 LIMITATIONS
 CONCLUSION
CONCEPT
The use of smaller diameter abutment on a
larger diameter implant collar.
Shifts the perimeter of the implant-
abutment junction (IAJ) inward toward the
central axis of the implant.
Reduces crestal bone loss.
5
HISTORY
• Accidental finding!
• In 1980s, dental implant manufacturers introduced wider diameter implants (5-6 mm).
• When introduced matching-diameter prosthetic components were unavailable.
• So, they were restored with standard diameter prosthetic components (4.1 mm)
Long-term radiographic follow-up of "platform-
switched" implants showed
Less crestal bone as compared to “platform
matched” implants
6
LAZZARA
PORTER,GARDNER
IN 2005
HOW PLATFORM SWITCHING REDUCES CRESTAL BONE LOSS?
Shifts the inflammatory cell infiltrate inward & away from crestal bone
Decreases influence of micro gap on crestal bone
Maintenance of biologic width
Decreases stress level in peri implant bone
7
HOW PLATFORM SWITCHING REDUCES CRESTAL BONE LOSS?
Shifts the inflammatory cell infiltrate inward & away from crestal bone.
Inflammatory cell infiltrate
IAJ Platform switching
IAJ inward and away from outer edge of implant and adjacent bone
Decreasing the effect of inflammatory cells on crestal bone
8
MAINTENANCE OF BIOLOGIC WIDTH
Provides additional horizontal biologic width.
Decreases stress level in peri implant bone
Platform switching
Shifts the stress concentration area away from bone-implant interface
Reduce crestal bone resorption
9
10
ADVANTAGES
Reduced crestal bone loss
Increased implant longevity
11
LIMITATIONS
• Deformation of abutment / screw.
• Compromise the emergence profile
in esthetic areas.
• Under sizing of the components
during all phases of the treatment.
12
CONCLUSION
 Crestal bone preservation
 Platform switching limits crestal
resorption
 It maintains the biological width
& helps improve esthetics
13
THANK YOU

PLATFORM SWITCHING

  • 1.
  • 2.
    2 PARTS OF ANIMPLANT RESTORATION Abutment Crown Titanium Implant Fitted over the Abutment for a natural appearance. Fitted over the portion of implant that protrudes from the gum line Surgically fused with the jawbone.
  • 3.
  • 4.
    CONTENTS  CONCEPT  HISTORY CRESTAL BONE LOSS  REDUCING CRESTAL BONE LOSS  ADVANTAGES  LIMITATIONS  CONCLUSION
  • 5.
    CONCEPT The use ofsmaller diameter abutment on a larger diameter implant collar. Shifts the perimeter of the implant- abutment junction (IAJ) inward toward the central axis of the implant. Reduces crestal bone loss. 5
  • 6.
    HISTORY • Accidental finding! •In 1980s, dental implant manufacturers introduced wider diameter implants (5-6 mm). • When introduced matching-diameter prosthetic components were unavailable. • So, they were restored with standard diameter prosthetic components (4.1 mm) Long-term radiographic follow-up of "platform- switched" implants showed Less crestal bone as compared to “platform matched” implants 6 LAZZARA PORTER,GARDNER IN 2005
  • 7.
    HOW PLATFORM SWITCHINGREDUCES CRESTAL BONE LOSS? Shifts the inflammatory cell infiltrate inward & away from crestal bone Decreases influence of micro gap on crestal bone Maintenance of biologic width Decreases stress level in peri implant bone 7
  • 8.
    HOW PLATFORM SWITCHINGREDUCES CRESTAL BONE LOSS? Shifts the inflammatory cell infiltrate inward & away from crestal bone. Inflammatory cell infiltrate IAJ Platform switching IAJ inward and away from outer edge of implant and adjacent bone Decreasing the effect of inflammatory cells on crestal bone 8
  • 9.
    MAINTENANCE OF BIOLOGICWIDTH Provides additional horizontal biologic width. Decreases stress level in peri implant bone Platform switching Shifts the stress concentration area away from bone-implant interface Reduce crestal bone resorption 9
  • 10.
  • 11.
    ADVANTAGES Reduced crestal boneloss Increased implant longevity 11
  • 12.
    LIMITATIONS • Deformation ofabutment / screw. • Compromise the emergence profile in esthetic areas. • Under sizing of the components during all phases of the treatment. 12
  • 13.
    CONCLUSION  Crestal bonepreservation  Platform switching limits crestal resorption  It maintains the biological width & helps improve esthetics 13
  • 14.