The document outlines 11 steps for sizing a pipe line to carry water at 100 m3/hr, including: calculating the internal pipe diameter, selecting the nearest available pipe size, determining the fluid velocity, calculating the Reynolds number and friction factor, determining equivalent length, calculating pressure drop, and comparing the available and calculated pressure drops. The goal is to select a pipe size that ensures the available pressure drop is greater than the calculated pressure drop.