This document summarizes a study that analyzes the seismic performance of a 24-story building both with and without base isolation. A base-isolated building model was created using lead-rubber bearings at the base, and both models were subjected to time history analysis using ground motion data from the 2001 Bhuj earthquake. The results show that the base-isolated building experienced significantly reduced story stiffness, story acceleration, story displacement and story drift compared to the fixed-base building, demonstrating the effectiveness of base isolation in improving seismic performance.
Effect of Friction Dampers on RC Structures Subjected to Earthquakeijtsrd
Among all the natural disasters such as flood, earthquake, drought, hurricanes the least understood and the most destructive one is earthquake. Since, they cause many of injuries and economical losses leaving behind a series of signs of panic. Necessity to implement seismic codes in building design. For this a better method of analysis such as static analysis, dynamic analysis and time history analysis has to be adopted for performing the structures seismic risk assessment. This dissertation work is concerned with the "Studies on Effect of Friction Dampers on the Seismic Performance of RC G 15 Storey Buildings" According to IS 1893 part 1 2002 codal provisions the structures are analyzed by Equivalent Static method and Time History method. The modeling and analysis is done with ETAB SOFTWARE and the results obtained are seismic parameters such as Time period, Base shear, Lateral displacement and Inter storey drift, storey stiffness, storey accelaration are tabulated and then comparative study of structures with and without Friction dampers has been done. Akshay R | B. S. Suresh Chandra "Effect of Friction Dampers on RC Structures Subjected to Earthquake" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd28017.pdfPaper URL: https://www.ijtsrd.com/engineering/structural-engineering/28017/effect-of-friction-dampers-on-rc-structures-subjected-to-earthquake/akshay-r
Effect of Friction Dampers on RC Structures Subjected to Earthquakeijtsrd
Among all the natural disasters such as flood, earthquake, drought, hurricanes the least understood and the most destructive one is earthquake. Since, they cause many of injuries and economical losses leaving behind a series of signs of panic. Necessity to implement seismic codes in building design. For this a better method of analysis such as static analysis, dynamic analysis and time history analysis has to be adopted for performing the structures seismic risk assessment. This dissertation work is concerned with the "Studies on Effect of Friction Dampers on the Seismic Performance of RC G 15 Storey Buildings" According to IS 1893 part 1 2002 codal provisions the structures are analyzed by Equivalent Static method and Time History method. The modeling and analysis is done with ETAB SOFTWARE and the results obtained are seismic parameters such as Time period, Base shear, Lateral displacement and Inter storey drift, storey stiffness, storey accelaration are tabulated and then comparative study of structures with and without Friction dampers has been done. Akshay R | B. S. Suresh Chandra "Effect of Friction Dampers on RC Structures Subjected to Earthquake" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd28017.pdfPaper URL: https://www.ijtsrd.com/engineering/structural-engineering/28017/effect-of-friction-dampers-on-rc-structures-subjected-to-earthquake/akshay-r
Seismic performance of r c buildings on sloping grounds with different types ...eSAT Journals
Abstract
Structure are highly susceptible to serve damages in earthquake scenario, so choosing an appropriate lateral force resisting
bracing systems will have a significant effect on performance of the structure. So this present study is aimed at evaluating and
comparing various types of eccentric steel bracings for 12 storey RC frame building resisting on sloping ground configurations.
For this 5 types of bracing systems like X-Bracing, Diagonal bracing, K- bracing, V-bracing and inverted V bracing are
considered on the outer periphery of the buildings with step back and set back – step back type configurations are modeled and
analyzed. The models are compared for different aspects within the structure, such as the maximum storey displacement, base
shear, storey drift and storey shear, the structure is analyzed for seismic zone V and medium soil condition as per IS 1893:2002
using ETABS software. Results conclude that on sloping ground due to irregularity on ground surface, the structures are more
vulnerable to earthquakes. Hence use of eccentric steel bracing is an effective and economical way to resist earthquake forces,
Inverted V type bracing performs well compared to other bracing types. By using inverted V type bracing in step back buildings
types maximum storey displacement of 70% and storey drift of 66% are obtained. Similarly for setback – step back configuration
maximum storey displacement of 74% and storey drift of 70% are obtained respectively.
Keywords: X-Bracing, Diagonal Bracing, K- Bracing, V-Bracing and Inverted V Bracing
Seismic analysis of high damping rubber bearings for base isolationeSAT Journals
Abstract
Base isolation is a mechanism that provides earthquake resistance to the new structure. The base isolation system decouples the building from the horizontal ground motion induced by earthquake, and offers very stiff vertical components to the base level of the superstructure in connection to substructure (foundation). It shifts the fundamental lateral period, dissipates the energy in damping, and reduces the amount of the lateral forces that transferred to the building, inter-story drift, and the floor acceleration.
The work deals with modelling and finite element analysis of a high damping rubber bearing in ANSYS 12.0. A displacement controlled transient analysis was done to analyse the behaviour of the isolator during earthquakes.
Keywords: Base isolation, High damping rubber, Transient analysis
Seismic analysis of multi storey reinforced concrete buildings frame”ankialok
The opinion that designing new buildings to be Earthquake resistant will cause substantial additional costs is still among the constructional professionals. In a country of moderate seismicity adequate seismic resistance of new buildings may be achieved at no or no significant additional cost however the expenditure needed to ensure adequate seismic resistance may depend strongly on the approach selected during the conceptual design phase and the relevant design method.
SEISMIC PROTECTION OF RC FRAMES USING FRICTION DAMPERSIAEME Publication
The increasing infrastructural growth incurs large investments and large section of society
being served by them, it is necessary to make them safer against earthquakes and let people
feel confident in their structures. The need for structural response control has gained pace in
application around the globe. This paper discusses the use and effectiveness of one such
device, friction dampers, for response control of structures. In this paper a non-linear time
history analysis has been carried out on a 3D model of a 12 story RCC MRF building using 3-
directional synthetic accelerogram. Two different cases of building models with and without
friction dampers have been analyzed using ETABS. The response of the structure to seismic
excitation in terms of absolute maximum displacement and story drift has been compared.
Time history response plots have also been compared for various responses viz. roof
displacement and acceleration, base shear and story shear forces, along with the various
energy components and damping behavior. The results of the time history analysis are in close
conformation with previous investigations and represent the effectiveness of dampers in
improving the structural response as well as damping demand on structural systems.
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERSIAEME Publication
Conventional methods of seismic rehabilitation with concrete shear walls or steel bracing
are not considered suitable for some buildings as upgrades with these methods would have
required expensive and time consuming foundation work. Supplemental damping in
conjunction with appropriate stiffness offers an innovative and attractive solution for the
seismic rehabilitation of such structures. This paper deals with the use of friction damper as a
passive dissipative device in order to seismic retrofit of existing structures and discusses the
optimal placement criteria. To fulfill this objective, six storey and ten storey L-shaped
buildings have been modeled with five different damper location formats in SAP2000 subjected
to El Centro and Utterkashi earthquake records. Non-Linear Modal Time History Method has
been used for the analysis and base shear, joint displacement, member forces and hysteresis
energy has been compared to find out most optimal damper location format.
The Lombok and Palu Earthquakes that have recently occurred in Indonesia caused
significant damage. Earthquakes are closely related to damage, landslide, and the loss
of life and economy. However, the causes of these things are not solely due to the
earthquake itself. The cause loss of life and economy caused solely due to the collapse
of buildings that built by humans during an earthquake. To reduce impact loss of life and
economy, Performance Based Seismic Design (PBSD) using based isolator can be one
of the solution. By using PBSD economic considerations the cost of repair after an
earthquake can be predicted. In this study, modeling 12-storey reinforced concrete
buildings located in Yogyakarta Indonesia stands on soft soil using base isolator High
Damping Rubber type (HDR HH090X4S, thickness 20 cm product of Bridgestone). The
average of non-linear dynamic time history analysis of seven ground motion respectively
Denali earthquake 2002, Imperial Valley 1940, Kobe 1995, Loma Prieta 1989,
Northridge 1994, San Fernando 1971, Superstition Hills 1987 was conducted. Seismic
response modification coefficient R was taken respectively 2.5, 3.5, 5.5, and 8. From
these coefficients, the performance of the building is obtained with R 2.5 and R 3.5
performance building in the category of immediate occupancy, R 5.5 and R 8 Category
damage control. Thus the building with R 2.5 and R 3.5 according to FEMA 273 will
produce a building with a repair cost of 25% and repair time only 1 day, so that after
the earthquake the building can resume normal operation
Seismic analysis of multi storey reinforced concrete buildings frame”ankialok
The opinion that designing new buildings to be Earthquake resistant will cause substantial additional costs is still among the constructional professionals. In a country of moderate seismicity adequate seismic resistance of new buildings may be achieved at no or no significant additional cost however the expenditure needed to ensure adequate seismic resistance may depend strongly on the approach selected during the conceptual design phase and the relevant design method. Regarding the conceptual design phase early collaboration between the architect and civil engineering is crucial.
Seismic performance of r c buildings on sloping grounds with different types ...eSAT Journals
Abstract
Structure are highly susceptible to serve damages in earthquake scenario, so choosing an appropriate lateral force resisting
bracing systems will have a significant effect on performance of the structure. So this present study is aimed at evaluating and
comparing various types of eccentric steel bracings for 12 storey RC frame building resisting on sloping ground configurations.
For this 5 types of bracing systems like X-Bracing, Diagonal bracing, K- bracing, V-bracing and inverted V bracing are
considered on the outer periphery of the buildings with step back and set back – step back type configurations are modeled and
analyzed. The models are compared for different aspects within the structure, such as the maximum storey displacement, base
shear, storey drift and storey shear, the structure is analyzed for seismic zone V and medium soil condition as per IS 1893:2002
using ETABS software. Results conclude that on sloping ground due to irregularity on ground surface, the structures are more
vulnerable to earthquakes. Hence use of eccentric steel bracing is an effective and economical way to resist earthquake forces,
Inverted V type bracing performs well compared to other bracing types. By using inverted V type bracing in step back buildings
types maximum storey displacement of 70% and storey drift of 66% are obtained. Similarly for setback – step back configuration
maximum storey displacement of 74% and storey drift of 70% are obtained respectively.
Keywords: X-Bracing, Diagonal Bracing, K- Bracing, V-Bracing and Inverted V Bracing
Seismic analysis of high damping rubber bearings for base isolationeSAT Journals
Abstract
Base isolation is a mechanism that provides earthquake resistance to the new structure. The base isolation system decouples the building from the horizontal ground motion induced by earthquake, and offers very stiff vertical components to the base level of the superstructure in connection to substructure (foundation). It shifts the fundamental lateral period, dissipates the energy in damping, and reduces the amount of the lateral forces that transferred to the building, inter-story drift, and the floor acceleration.
The work deals with modelling and finite element analysis of a high damping rubber bearing in ANSYS 12.0. A displacement controlled transient analysis was done to analyse the behaviour of the isolator during earthquakes.
Keywords: Base isolation, High damping rubber, Transient analysis
Seismic analysis of multi storey reinforced concrete buildings frame”ankialok
The opinion that designing new buildings to be Earthquake resistant will cause substantial additional costs is still among the constructional professionals. In a country of moderate seismicity adequate seismic resistance of new buildings may be achieved at no or no significant additional cost however the expenditure needed to ensure adequate seismic resistance may depend strongly on the approach selected during the conceptual design phase and the relevant design method.
SEISMIC PROTECTION OF RC FRAMES USING FRICTION DAMPERSIAEME Publication
The increasing infrastructural growth incurs large investments and large section of society
being served by them, it is necessary to make them safer against earthquakes and let people
feel confident in their structures. The need for structural response control has gained pace in
application around the globe. This paper discusses the use and effectiveness of one such
device, friction dampers, for response control of structures. In this paper a non-linear time
history analysis has been carried out on a 3D model of a 12 story RCC MRF building using 3-
directional synthetic accelerogram. Two different cases of building models with and without
friction dampers have been analyzed using ETABS. The response of the structure to seismic
excitation in terms of absolute maximum displacement and story drift has been compared.
Time history response plots have also been compared for various responses viz. roof
displacement and acceleration, base shear and story shear forces, along with the various
energy components and damping behavior. The results of the time history analysis are in close
conformation with previous investigations and represent the effectiveness of dampers in
improving the structural response as well as damping demand on structural systems.
SEISMIC RESPONSE OF UNSYMMETRIC BUILDING WITH OPTIMALLY PLACED FRICTION DAMPERSIAEME Publication
Conventional methods of seismic rehabilitation with concrete shear walls or steel bracing
are not considered suitable for some buildings as upgrades with these methods would have
required expensive and time consuming foundation work. Supplemental damping in
conjunction with appropriate stiffness offers an innovative and attractive solution for the
seismic rehabilitation of such structures. This paper deals with the use of friction damper as a
passive dissipative device in order to seismic retrofit of existing structures and discusses the
optimal placement criteria. To fulfill this objective, six storey and ten storey L-shaped
buildings have been modeled with five different damper location formats in SAP2000 subjected
to El Centro and Utterkashi earthquake records. Non-Linear Modal Time History Method has
been used for the analysis and base shear, joint displacement, member forces and hysteresis
energy has been compared to find out most optimal damper location format.
The Lombok and Palu Earthquakes that have recently occurred in Indonesia caused
significant damage. Earthquakes are closely related to damage, landslide, and the loss
of life and economy. However, the causes of these things are not solely due to the
earthquake itself. The cause loss of life and economy caused solely due to the collapse
of buildings that built by humans during an earthquake. To reduce impact loss of life and
economy, Performance Based Seismic Design (PBSD) using based isolator can be one
of the solution. By using PBSD economic considerations the cost of repair after an
earthquake can be predicted. In this study, modeling 12-storey reinforced concrete
buildings located in Yogyakarta Indonesia stands on soft soil using base isolator High
Damping Rubber type (HDR HH090X4S, thickness 20 cm product of Bridgestone). The
average of non-linear dynamic time history analysis of seven ground motion respectively
Denali earthquake 2002, Imperial Valley 1940, Kobe 1995, Loma Prieta 1989,
Northridge 1994, San Fernando 1971, Superstition Hills 1987 was conducted. Seismic
response modification coefficient R was taken respectively 2.5, 3.5, 5.5, and 8. From
these coefficients, the performance of the building is obtained with R 2.5 and R 3.5
performance building in the category of immediate occupancy, R 5.5 and R 8 Category
damage control. Thus the building with R 2.5 and R 3.5 according to FEMA 273 will
produce a building with a repair cost of 25% and repair time only 1 day, so that after
the earthquake the building can resume normal operation
Seismic analysis of multi storey reinforced concrete buildings frame”ankialok
The opinion that designing new buildings to be Earthquake resistant will cause substantial additional costs is still among the constructional professionals. In a country of moderate seismicity adequate seismic resistance of new buildings may be achieved at no or no significant additional cost however the expenditure needed to ensure adequate seismic resistance may depend strongly on the approach selected during the conceptual design phase and the relevant design method. Regarding the conceptual design phase early collaboration between the architect and civil engineering is crucial.
Seismic Performance of Reinforced Cement Concrete Structures with and Without...ijtsrd
Passive energy dissipation have been used so far to dissipate the unwanted energy due to earthquake and heavy wind actions. The complete failure of the structures that has occurred in the past due to catastrophic earthquakes may be avoided with the use of such devices. The study is concerned with the use of accordion metallic dampers that uses hysteretic energy to dissipate the unwanted energy due to earthquake. It consists of corrugated thin wall tubes installed as a brace connection in the frame. The axial deformation of the accordion damper enhances the lateral buckling capacity and results in maximum reduction of the damaging measures. The study emphasizes the use of such dampers and in depth analysis is performed by subjecting the building to base excitations in order to assess the nonlinear performance of the dampers installed in the building Rahul Tahilyani | Dilip Budhlani ""Seismic Performance of Reinforced Cement Concrete Structures with and Without Viscous Dampers"" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-2 , February 2020,
URL: https://www.ijtsrd.com/papers/ijtsrd30122.pdf
Paper Url : https://www.ijtsrd.com/engineering/civil-engineering/30122/seismic-performance-of-reinforced-cement-concrete-structures-with-and-without-viscous-dampers/rahul-tahilyani
Comparision of building for sesmic response by using base isolationeSAT Journals
Abstract
Throughout historic time Earthquakes are one of the natural hazards that occur due to sudden violent movement of earth’s
surface which causes damage to property, especially to man-made structures . Base isolation is one of the most powerful tools of
earthquake engineering pertaining to the passive structural vibration control technologies. The application of the base isolation
techniques to protect structures against damage from earthquake attacks has been considered as one of the most effective
approaches and has gained increasing acceptance during the last two decades. This paper present three dimensional nonlinear
time history analysis is performed on r/c building by the use of computer program SAP 2000 v12.0.0. The dynamic analysis of the
structure has been carried out and the performance of the building with and without isolator is studied. The main objective here is
to make seismic response control by providing Isolators and comparing between the fixed based and isolated base building.
Rubber bearing and Friction pendulum bearing are used
Keywords: Base Isolation; Seismic Response; Time History
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
TECHNICAL TRAINING MANUAL GENERAL FAMILIARIZATION COURSEDuvanRamosGarzon1
AIRCRAFT GENERAL
The Single Aisle is the most advanced family aircraft in service today, with fly-by-wire flight controls.
The A318, A319, A320 and A321 are twin-engine subsonic medium range aircraft.
The family offers a choice of engines
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Courier management system project report.pdfKamal Acharya
It is now-a-days very important for the people to send or receive articles like imported furniture, electronic items, gifts, business goods and the like. People depend vastly on different transport systems which mostly use the manual way of receiving and delivering the articles. There is no way to track the articles till they are received and there is no way to let the customer know what happened in transit, once he booked some articles. In such a situation, we need a system which completely computerizes the cargo activities including time to time tracking of the articles sent. This need is fulfilled by Courier Management System software which is online software for the cargo management people that enables them to receive the goods from a source and send them to a required destination and track their status from time to time.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Democratizing Fuzzing at Scale by Abhishek Aryaabh.arya
Presented at NUS: Fuzzing and Software Security Summer School 2024
This keynote talks about the democratization of fuzzing at scale, highlighting the collaboration between open source communities, academia, and industry to advance the field of fuzzing. It delves into the history of fuzzing, the development of scalable fuzzing platforms, and the empowerment of community-driven research. The talk will further discuss recent advancements leveraging AI/ML and offer insights into the future evolution of the fuzzing landscape.
Automobile Management System Project Report.pdfKamal Acharya
The proposed project is developed to manage the automobile in the automobile dealer company. The main module in this project is login, automobile management, customer management, sales, complaints and reports. The first module is the login. The automobile showroom owner should login to the project for usage. The username and password are verified and if it is correct, next form opens. If the username and password are not correct, it shows the error message.
When a customer search for a automobile, if the automobile is available, they will be taken to a page that shows the details of the automobile including automobile name, automobile ID, quantity, price etc. “Automobile Management System” is useful for maintaining automobiles, customers effectively and hence helps for establishing good relation between customer and automobile organization. It contains various customized modules for effectively maintaining automobiles and stock information accurately and safely.
When the automobile is sold to the customer, stock will be reduced automatically. When a new purchase is made, stock will be increased automatically. While selecting automobiles for sale, the proposed software will automatically check for total number of available stock of that particular item, if the total stock of that particular item is less than 5, software will notify the user to purchase the particular item.
Also when the user tries to sale items which are not in stock, the system will prompt the user that the stock is not enough. Customers of this system can search for a automobile; can purchase a automobile easily by selecting fast. On the other hand the stock of automobiles can be maintained perfectly by the automobile shop manager overcoming the drawbacks of existing system.