Seismic analysis of high damping rubber bearings for base isolationeSAT Journals
Abstract
Base isolation is a mechanism that provides earthquake resistance to the new structure. The base isolation system decouples the building from the horizontal ground motion induced by earthquake, and offers very stiff vertical components to the base level of the superstructure in connection to substructure (foundation). It shifts the fundamental lateral period, dissipates the energy in damping, and reduces the amount of the lateral forces that transferred to the building, inter-story drift, and the floor acceleration.
The work deals with modelling and finite element analysis of a high damping rubber bearing in ANSYS 12.0. A displacement controlled transient analysis was done to analyse the behaviour of the isolator during earthquakes.
Keywords: Base isolation, High damping rubber, Transient analysis
Study on laminated rubber bearing base isolators for seismic protection of st...eSAT Journals
Abstract
Base isolation or seismic base isolation is an effective means for protection of structures, its contents and its occupants during the event of an earthquake. The principle of base isolation is vibration isolation. It decouples the building from damaging action of the earthquake. The isolator partially reflects and partially absorbs input seismic energy before it gets transmitted to the superstructure. Laminated Rubber Bearing Isolators are placed between the superstructure and foundation, which reduces the horizontal stiffness of the system. It thereby increases the time period of the structure and decreases the spectral acceleration of the structure. The superstructure acts like a rigid body, thus inter storey drift is reduced. Such type of isolators are used in practice in India, yet a proper design procedure based on IS code is unavailable. The paper presents design procedure for LRB adopting the procedure of IS 1893:2002 (Part-1) for earthquake resistant design of buildings. Design charts have been developed and presented in this paper which gives isolator diameter and rubber thickness as design outputs. The design procedure requires different input parameters like fundamental period and damping of the fixed base structure, axial load on the column, seismic zone, type of soil and shore hardness of rubber. These design charts enable the designer to easily arrive at the isolator parameters to achieve seismic isolation. Using the charts, case study has been done using SAP2000. Building displacement and acceleration are compared for model with and without base isolator. Comparative study of linear and non-linear base isolators has also been carried out. Linear and non-linear time history analysis has been done using El Centro earthquake.
Keywords: base isolation, laminated rubber bearing, IS Code, seismic protection, design charts, time history analysis, SAP2000
Seismic analysis of high damping rubber bearings for base isolationeSAT Journals
Abstract
Base isolation is a mechanism that provides earthquake resistance to the new structure. The base isolation system decouples the building from the horizontal ground motion induced by earthquake, and offers very stiff vertical components to the base level of the superstructure in connection to substructure (foundation). It shifts the fundamental lateral period, dissipates the energy in damping, and reduces the amount of the lateral forces that transferred to the building, inter-story drift, and the floor acceleration.
The work deals with modelling and finite element analysis of a high damping rubber bearing in ANSYS 12.0. A displacement controlled transient analysis was done to analyse the behaviour of the isolator during earthquakes.
Keywords: Base isolation, High damping rubber, Transient analysis
Study on laminated rubber bearing base isolators for seismic protection of st...eSAT Journals
Abstract
Base isolation or seismic base isolation is an effective means for protection of structures, its contents and its occupants during the event of an earthquake. The principle of base isolation is vibration isolation. It decouples the building from damaging action of the earthquake. The isolator partially reflects and partially absorbs input seismic energy before it gets transmitted to the superstructure. Laminated Rubber Bearing Isolators are placed between the superstructure and foundation, which reduces the horizontal stiffness of the system. It thereby increases the time period of the structure and decreases the spectral acceleration of the structure. The superstructure acts like a rigid body, thus inter storey drift is reduced. Such type of isolators are used in practice in India, yet a proper design procedure based on IS code is unavailable. The paper presents design procedure for LRB adopting the procedure of IS 1893:2002 (Part-1) for earthquake resistant design of buildings. Design charts have been developed and presented in this paper which gives isolator diameter and rubber thickness as design outputs. The design procedure requires different input parameters like fundamental period and damping of the fixed base structure, axial load on the column, seismic zone, type of soil and shore hardness of rubber. These design charts enable the designer to easily arrive at the isolator parameters to achieve seismic isolation. Using the charts, case study has been done using SAP2000. Building displacement and acceleration are compared for model with and without base isolator. Comparative study of linear and non-linear base isolators has also been carried out. Linear and non-linear time history analysis has been done using El Centro earthquake.
Keywords: base isolation, laminated rubber bearing, IS Code, seismic protection, design charts, time history analysis, SAP2000
Comparision of building for sesmic response by using base isolationeSAT Journals
Abstract
Throughout historic time Earthquakes are one of the natural hazards that occur due to sudden violent movement of earth’s
surface which causes damage to property, especially to man-made structures . Base isolation is one of the most powerful tools of
earthquake engineering pertaining to the passive structural vibration control technologies. The application of the base isolation
techniques to protect structures against damage from earthquake attacks has been considered as one of the most effective
approaches and has gained increasing acceptance during the last two decades. This paper present three dimensional nonlinear
time history analysis is performed on r/c building by the use of computer program SAP 2000 v12.0.0. The dynamic analysis of the
structure has been carried out and the performance of the building with and without isolator is studied. The main objective here is
to make seismic response control by providing Isolators and comparing between the fixed based and isolated base building.
Rubber bearing and Friction pendulum bearing are used
Keywords: Base Isolation; Seismic Response; Time History
Seismic Analysis of Framed R.C. Structure with Base Isolation Technique using...ijtsrd
A Natural Calamity like an earthquake has taken a million lives throughout in our past. The force induced due to earthquake is dangerous and last for short duration of time. There are various techniques that can be used resist the force of an earthquake such as base isolation, bracing etc. The principle of base isolation is to isolate the structure from the motion of an earthquake and protect the structure and also reduce the force being transmitted to the building due to earthquake. For this study, G 13 storied R.C. frame building is considered and time history analysis is carried out using E Tabs 2017 software, and also study investigates structural behavior of multi story building with or without base isolation subjected earthquake ground motion. The Lead Rubber Bearing LRB is designed as per UBC 97 code and the same was used for the analysis of base isolation system. Here we shall studying earthquake resistivity of structure by analyzing the base isolation structure to compare its structural performance with fixed base isolation. Rohan G Raikar | Dr. Shivakumaraswamy | Dr. S Vijaya | M. K Darshan "Seismic Analysis of Framed R.C. Structure with Base Isolation Technique using E-Tabs" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-4 | Issue-5 , August 2020, URL: https://www.ijtsrd.com/papers/ijtsrd33166.pdf Paper Url :https://www.ijtsrd.com/engineering/civil-engineering/33166/seismic-analysis-of-framed-rc-structure-with-base-isolation-technique-using-etabs/rohan-g-raikar
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.