This document presents an analysis of a G+25 reinforced concrete bare framed structure with shear walls under seismic loads. Four models are analyzed with shear walls placed at different locations (intermediate, corner, middle, core) and compared to a conventional structure without shear walls. The objectives are to analyze seismic forces for Zone III and compare bending moments and shear forces. The methodology uses STAAD Pro V8i to model and analyze the structures. Results show that the model with a shear wall at the corner performs best, with bending moments reduced by 37% compared to the conventional structure without shear walls. In conclusion, adding shear walls, especially at the corner, improves a structure's ability to resist seismic forces.
Seismic performance of r c buildings on sloping grounds with different types ...eSAT Journals
Abstract
Structure are highly susceptible to serve damages in earthquake scenario, so choosing an appropriate lateral force resisting
bracing systems will have a significant effect on performance of the structure. So this present study is aimed at evaluating and
comparing various types of eccentric steel bracings for 12 storey RC frame building resisting on sloping ground configurations.
For this 5 types of bracing systems like X-Bracing, Diagonal bracing, K- bracing, V-bracing and inverted V bracing are
considered on the outer periphery of the buildings with step back and set back – step back type configurations are modeled and
analyzed. The models are compared for different aspects within the structure, such as the maximum storey displacement, base
shear, storey drift and storey shear, the structure is analyzed for seismic zone V and medium soil condition as per IS 1893:2002
using ETABS software. Results conclude that on sloping ground due to irregularity on ground surface, the structures are more
vulnerable to earthquakes. Hence use of eccentric steel bracing is an effective and economical way to resist earthquake forces,
Inverted V type bracing performs well compared to other bracing types. By using inverted V type bracing in step back buildings
types maximum storey displacement of 70% and storey drift of 66% are obtained. Similarly for setback – step back configuration
maximum storey displacement of 74% and storey drift of 70% are obtained respectively.
Keywords: X-Bracing, Diagonal Bracing, K- Bracing, V-Bracing and Inverted V Bracing
Effect of Friction Dampers on RC Structures Subjected to Earthquakeijtsrd
Among all the natural disasters such as flood, earthquake, drought, hurricanes the least understood and the most destructive one is earthquake. Since, they cause many of injuries and economical losses leaving behind a series of signs of panic. Necessity to implement seismic codes in building design. For this a better method of analysis such as static analysis, dynamic analysis and time history analysis has to be adopted for performing the structures seismic risk assessment. This dissertation work is concerned with the "Studies on Effect of Friction Dampers on the Seismic Performance of RC G 15 Storey Buildings" According to IS 1893 part 1 2002 codal provisions the structures are analyzed by Equivalent Static method and Time History method. The modeling and analysis is done with ETAB SOFTWARE and the results obtained are seismic parameters such as Time period, Base shear, Lateral displacement and Inter storey drift, storey stiffness, storey accelaration are tabulated and then comparative study of structures with and without Friction dampers has been done. Akshay R | B. S. Suresh Chandra "Effect of Friction Dampers on RC Structures Subjected to Earthquake" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd28017.pdfPaper URL: https://www.ijtsrd.com/engineering/structural-engineering/28017/effect-of-friction-dampers-on-rc-structures-subjected-to-earthquake/akshay-r
Seismic performance of r c buildings on sloping grounds with different types ...eSAT Journals
Abstract
Structure are highly susceptible to serve damages in earthquake scenario, so choosing an appropriate lateral force resisting
bracing systems will have a significant effect on performance of the structure. So this present study is aimed at evaluating and
comparing various types of eccentric steel bracings for 12 storey RC frame building resisting on sloping ground configurations.
For this 5 types of bracing systems like X-Bracing, Diagonal bracing, K- bracing, V-bracing and inverted V bracing are
considered on the outer periphery of the buildings with step back and set back – step back type configurations are modeled and
analyzed. The models are compared for different aspects within the structure, such as the maximum storey displacement, base
shear, storey drift and storey shear, the structure is analyzed for seismic zone V and medium soil condition as per IS 1893:2002
using ETABS software. Results conclude that on sloping ground due to irregularity on ground surface, the structures are more
vulnerable to earthquakes. Hence use of eccentric steel bracing is an effective and economical way to resist earthquake forces,
Inverted V type bracing performs well compared to other bracing types. By using inverted V type bracing in step back buildings
types maximum storey displacement of 70% and storey drift of 66% are obtained. Similarly for setback – step back configuration
maximum storey displacement of 74% and storey drift of 70% are obtained respectively.
Keywords: X-Bracing, Diagonal Bracing, K- Bracing, V-Bracing and Inverted V Bracing
Effect of Friction Dampers on RC Structures Subjected to Earthquakeijtsrd
Among all the natural disasters such as flood, earthquake, drought, hurricanes the least understood and the most destructive one is earthquake. Since, they cause many of injuries and economical losses leaving behind a series of signs of panic. Necessity to implement seismic codes in building design. For this a better method of analysis such as static analysis, dynamic analysis and time history analysis has to be adopted for performing the structures seismic risk assessment. This dissertation work is concerned with the "Studies on Effect of Friction Dampers on the Seismic Performance of RC G 15 Storey Buildings" According to IS 1893 part 1 2002 codal provisions the structures are analyzed by Equivalent Static method and Time History method. The modeling and analysis is done with ETAB SOFTWARE and the results obtained are seismic parameters such as Time period, Base shear, Lateral displacement and Inter storey drift, storey stiffness, storey accelaration are tabulated and then comparative study of structures with and without Friction dampers has been done. Akshay R | B. S. Suresh Chandra "Effect of Friction Dampers on RC Structures Subjected to Earthquake" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5 , August 2019, URL: https://www.ijtsrd.com/papers/ijtsrd28017.pdfPaper URL: https://www.ijtsrd.com/engineering/structural-engineering/28017/effect-of-friction-dampers-on-rc-structures-subjected-to-earthquake/akshay-r
Review paper on seismic responses of multistored rcc building with mass irreg...eSAT Journals
Abstract
From past earthquakes it is proved that many of structure are totally or partially damaged due to earthquake. So, it is necessary to determine seismic responses of such buildings. There are different techniques of seismic analysis of structure. Time history analysis is one of the important techniques for structural seismic analysis generally the evaluated structural response is non-linear in nature. For such type of analysis, a representative earthquake time history is required. In this project work seismic analysis of RCC buildings with mass irregularity at different floor level are carried out. Here for analysis different time histories have been used. This paper highlights the effect of mass irregularity on different floor in RCC buildings with time history and analysis is done by using ETABS software.
Keywords: Seismic Analysis, Time History Analysis, Base Shear, Storey Shear, Story Displacement.
Review paper on seismic responses of multistored rcc building with mass irreg...eSAT Journals
Abstract
From past earthquakes it is proved that many of structure are totally or partially damaged due to earthquake. So, it is necessary to determine seismic responses of such buildings. There are different techniques of seismic analysis of structure. Time history analysis is one of the important techniques for structural seismic analysis generally the evaluated structural response is non-linear in nature. For such type of analysis, a representative earthquake time history is required. In this project work seismic analysis of RCC buildings with mass irregularity at different floor level are carried out. Here for analysis different time histories have been used. This paper highlights the effect of mass irregularity on different floor in RCC buildings with time history and analysis is done by using ETABS software.
Keywords: Seismic Analysis, Time History Analysis, Base Shear, Storey Shear, Story Displacement.
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
Hierarchical Digital Twin of a Naval Power SystemKerry Sado
A hierarchical digital twin of a Naval DC power system has been developed and experimentally verified. Similar to other state-of-the-art digital twins, this technology creates a digital replica of the physical system executed in real-time or faster, which can modify hardware controls. However, its advantage stems from distributing computational efforts by utilizing a hierarchical structure composed of lower-level digital twin blocks and a higher-level system digital twin. Each digital twin block is associated with a physical subsystem of the hardware and communicates with a singular system digital twin, which creates a system-level response. By extracting information from each level of the hierarchy, power system controls of the hardware were reconfigured autonomously. This hierarchical digital twin development offers several advantages over other digital twins, particularly in the field of naval power systems. The hierarchical structure allows for greater computational efficiency and scalability while the ability to autonomously reconfigure hardware controls offers increased flexibility and responsiveness. The hierarchical decomposition and models utilized were well aligned with the physical twin, as indicated by the maximum deviations between the developed digital twin hierarchy and the hardware.
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.