This document summarizes a study that analyzed the seismic performance of different configurations of outrigger systems in high-rise buildings using time history analysis. Five 35-story building models were analyzed: 1) bare frame, 2) two outriggers, 3) two outriggers with belt truss, 4) three outriggers, and 5) two outriggers with mega columns. The models were subjected to time history analyses using earthquake records. Results showed that using multiple outriggers and mega columns reduced top story displacements, inter-story drifts, and building period compared to the bare frame model, with two outriggers with mega columns performing the best. Outriggers significantly reduced drift at outrigger levels,
Dynamic Response of High Rise Structures Under The Influence of Shear WallsIJERA Editor
This study presents the procedure for seismic performance estimation of high-rise buildings based on a concept of the capacity spectrum method. In 3D analytical model of thirty storied buildings have been generated for symmetric buildings Models and analyzed using structural analysis tool ETABS. The analytical model of the building includes all important components that influence the mass, strength, stiffness and deformability of the structure. To study the effect of concrete core wall & shear wall at different positions during earthquake, seismic analysis using both linear static, linear dynamic and non-linear static procedure has been performed. The deflections at each storey level has been compared by performing Equivalent static, response spectrum method as well as pushover method has also been performed to determine capacity, demand and performance level of the considered building models. From the below studies it has been observed that non-linear pushover analysis provide good estimate of global as well as local inelastic deformation demands and also reveals design weakness that may remain hidden in an elastic analysis and also the performance level of the structure. Storey drifts are found within the limit as specified by code (IS: 1893-2002) in Equivalent static, linear dynamic & non-linear static analysis.
seismic response of multi storey building equipped with steel bracingINFOGAIN PUBLICATION
Steel bracing has proven to be one of the most effective systems in resisting lateral loads. Although its use to upgrade the lateral load capacity of existing Reinforced Concrete (RC) frames has been the subject of numerous studies, guidelines for its use in newly constructed RC frames still need to be developed. In this paper the study reveals that seismic performance of moment resisting RC frames with different patterns of bracing system. The three different types of bracings were used i.e. X - bracing system, V - bracing system and Inverted V - bracing system. This arrangement helped in reducing the structural response (i.e. displacement, interstorey drift, Shear Forces & Bending Moments) of the designed building structure. An (G+6) storey building was modelled and designed as per the code provisions of IS-1893:2002. And linear analysis is been carried out in the global X direction. The analysis was conducted with a view of accessing the seismic elastic performance of the building structure.
Dynamic Response of High Rise Structures Under The Influence of Shear WallsIJERA Editor
This study presents the procedure for seismic performance estimation of high-rise buildings based on a concept of the capacity spectrum method. In 3D analytical model of thirty storied buildings have been generated for symmetric buildings Models and analyzed using structural analysis tool ETABS. The analytical model of the building includes all important components that influence the mass, strength, stiffness and deformability of the structure. To study the effect of concrete core wall & shear wall at different positions during earthquake, seismic analysis using both linear static, linear dynamic and non-linear static procedure has been performed. The deflections at each storey level has been compared by performing Equivalent static, response spectrum method as well as pushover method has also been performed to determine capacity, demand and performance level of the considered building models. From the below studies it has been observed that non-linear pushover analysis provide good estimate of global as well as local inelastic deformation demands and also reveals design weakness that may remain hidden in an elastic analysis and also the performance level of the structure. Storey drifts are found within the limit as specified by code (IS: 1893-2002) in Equivalent static, linear dynamic & non-linear static analysis.
seismic response of multi storey building equipped with steel bracingINFOGAIN PUBLICATION
Steel bracing has proven to be one of the most effective systems in resisting lateral loads. Although its use to upgrade the lateral load capacity of existing Reinforced Concrete (RC) frames has been the subject of numerous studies, guidelines for its use in newly constructed RC frames still need to be developed. In this paper the study reveals that seismic performance of moment resisting RC frames with different patterns of bracing system. The three different types of bracings were used i.e. X - bracing system, V - bracing system and Inverted V - bracing system. This arrangement helped in reducing the structural response (i.e. displacement, interstorey drift, Shear Forces & Bending Moments) of the designed building structure. An (G+6) storey building was modelled and designed as per the code provisions of IS-1893:2002. And linear analysis is been carried out in the global X direction. The analysis was conducted with a view of accessing the seismic elastic performance of the building structure.
Pushover analysis of rc frame structure with floating column and soft story i...eSAT Journals
Abstract Open first story and Floating column are typical features in the modern multi-storey constructions in urban India. Such features are highly undesirable in buildings built in seismically active areas; this has been verified in numerous experiences of strong shaking during the past earthquakes like Bhuj 2001. In this study an attempt is made to reveal the effects of floating column & soft story in different earthquake zones by seismic analysis. For this purpose Push over analysis is adopted because this analysis will yield performance level of building for design capacity (displacement) carried out up to failure, it helps determination of collapse load and ductility capacity of the structure. To achieve this objective, three RC bare frame structures with G+4, G+9, G+15 stories respectively will be analysed and compared the base force and displacement of RC bare frame structure with G+4, G+9, G+15 stories in different earthquake zones like Rajkot, Jamnagar and Bhuj using SAP 2000 14 analysis package. Keywords: - floating column, soft story, pushover analysis, earthquake resistant structure
Seismic evelution of rc space frame with rectangular and equivalent square co...eSAT Publishing House
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Progressive Collapse Analysis of RC Framed StructuresAmit Devar
The term progressive collapse defined as the
spread of local damage, from an initiating event, from
element to element resulting, eventually, in the collapse of an
entire structure or a disproportionately large part of it is
known as progressive collapse. The progressive collapse of
structures during severe loading caused by earthquakes,
blasts, and other effects causes catastrophic loss of life. Such
collapse is typically caused by the inability of the structural
system to redistribute its loads following the failure of one or
more structural members to carry gravity loads. In reinforced
concrete (RC) structures, the loss of gravity load carrying
capacity in column.
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...IAEME Publication
The construction of multi-storey buildings is increasing constantly all over the world. The
development of highly advanced structural system is mainly based on the quality of aesthetic
expression, structural efficiency, and geometric versatility. The selected structural system should be
such that it has to be effectively utilized for structural requirements. The unique geometrical
configuration of the diagrid structural systems have driven them to be used for high rise buildings
providing the structural efficiency and aesthetic potential. In this present work, four different
models of I section of a 30 storey RC Frame building with plan size 18 m × 18 m located in seismic
zone V have been considered for analysis. Steel diagrid structure of 2 storey and 6 storey models
and Infill wall model are analyzed and compared with conventional RC Frame model and is
studied using linear dynamic analysis. ETabs software is used for modeling and analysis of
structural members. Comparison of analysis results in terms of storey Displacement, Drift, Bending
Moment, Axial forces, Time period, Base shear is presented and the results obtained were
compared with those obtained from other models.
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that publishes research and review articles in the fields of Computer Science, Neural Networks, Electrical Engineering, Software Engineering, Information Technology, Mechanical Engineering, Chemical Engineering, Plastic Engineering, Food Technology, Textile Engineering, Nano Technology & science, Power Electronics, Electronics & Communication Engineering, Computational mathematics, Image processing, Civil Engineering, Structural Engineering, Environmental Engineering, VLSI Testing & Low Power VLSI Design etc.
Effect of variation of plastic hinge length on the results of non linear anal...eSAT Journals
Abstract The nonlinear Static procedure also well known as pushover analysis is method where in monotonically increasing loads are applied to the structure till the structure is unable to resist any further load. It is a popular tool for seismic performance evaluation of existing and new structures. In literature lot of research has been carried out on conventional pushover analysis and after knowing deficiency efforts have been made to improve it. But actual test results to verify the analytically obtained pushover results are rarely available. It has been found that some amount of variation is always expected to exist in seismic demand prediction of pushover analysis. Initial study is carried out by considering user defined hinge properties and default hinge length. Attempt is being made to assess the variation of pushover analysis results by considering user defined hinge properties and various hinge length formulations available in literature and results compared with experimentally obtained results based on test carried out on a G+2 storied RCC framed structure. For the present study two geometric models viz bare frame and rigid frame model is considered and it is found that the results of pushover analysis are very sensitive to geometric model and hinge length adopted. Keywords: Pushover analysis, Base shear, Displacement, hinge length, moment curvature analysis
Analysis and Optimum Design for Steel Moment Resisting Frames to Seismic Exci...IJCMESJOURNAL
The essential purpose of this wander is to develop an Interior Penalty Function (IPF) based estimation to multi-storey steel traces for slightest weight of frames. The frames are proposed for contradicting even impact in view of seismic stacking close by gravity forces. Various structural stems are used for restricting seismic (lateral) forces; however steel moment resisting frames (MRFs) are considered for the present work. The framework solidifies codal courses of action of IS 800-2007, as needs be gets the edges with perfect weight for in-plane moments with lateral support of beam element. Strength and buckling criteria are considered as direct goals close by side constraints in formulating optimization problem. A Software program is made that uses an interior penalty function (IPF) for weight minimization of two-dimensional moment restricting steel encompassed structures. The program uses MATLAB, performs one dimensional interest, and structural design in an iterative technique. The design cases have exhibited that the proposed estimation gives a beneficial instrument to the practicing fundamental algorithm. The program is associated with 6 and 9 storey (4 bays) moment resisting frames (MRFs). The program showed its capacity of optimizing the largeness of two medium size frames. To get part obliges in frames an examination technique must be associated. In the present work Equivalent Lateral Force framework (ELF) and material nonlinear time history analysis (NTH) are associated and perfect qualities gained from both the examinations are contemplated.
Pushover analysis of rc frame structure with floating column and soft story i...eSAT Journals
Abstract Open first story and Floating column are typical features in the modern multi-storey constructions in urban India. Such features are highly undesirable in buildings built in seismically active areas; this has been verified in numerous experiences of strong shaking during the past earthquakes like Bhuj 2001. In this study an attempt is made to reveal the effects of floating column & soft story in different earthquake zones by seismic analysis. For this purpose Push over analysis is adopted because this analysis will yield performance level of building for design capacity (displacement) carried out up to failure, it helps determination of collapse load and ductility capacity of the structure. To achieve this objective, three RC bare frame structures with G+4, G+9, G+15 stories respectively will be analysed and compared the base force and displacement of RC bare frame structure with G+4, G+9, G+15 stories in different earthquake zones like Rajkot, Jamnagar and Bhuj using SAP 2000 14 analysis package. Keywords: - floating column, soft story, pushover analysis, earthquake resistant structure
Seismic evelution of rc space frame with rectangular and equivalent square co...eSAT Publishing House
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Progressive Collapse Analysis of RC Framed StructuresAmit Devar
The term progressive collapse defined as the
spread of local damage, from an initiating event, from
element to element resulting, eventually, in the collapse of an
entire structure or a disproportionately large part of it is
known as progressive collapse. The progressive collapse of
structures during severe loading caused by earthquakes,
blasts, and other effects causes catastrophic loss of life. Such
collapse is typically caused by the inability of the structural
system to redistribute its loads following the failure of one or
more structural members to carry gravity loads. In reinforced
concrete (RC) structures, the loss of gravity load carrying
capacity in column.
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...IAEME Publication
The construction of multi-storey buildings is increasing constantly all over the world. The
development of highly advanced structural system is mainly based on the quality of aesthetic
expression, structural efficiency, and geometric versatility. The selected structural system should be
such that it has to be effectively utilized for structural requirements. The unique geometrical
configuration of the diagrid structural systems have driven them to be used for high rise buildings
providing the structural efficiency and aesthetic potential. In this present work, four different
models of I section of a 30 storey RC Frame building with plan size 18 m × 18 m located in seismic
zone V have been considered for analysis. Steel diagrid structure of 2 storey and 6 storey models
and Infill wall model are analyzed and compared with conventional RC Frame model and is
studied using linear dynamic analysis. ETabs software is used for modeling and analysis of
structural members. Comparison of analysis results in terms of storey Displacement, Drift, Bending
Moment, Axial forces, Time period, Base shear is presented and the results obtained were
compared with those obtained from other models.
International Journal of Engineering Research and Applications (IJERA) is an open access online peer reviewed international journal that publishes research and review articles in the fields of Computer Science, Neural Networks, Electrical Engineering, Software Engineering, Information Technology, Mechanical Engineering, Chemical Engineering, Plastic Engineering, Food Technology, Textile Engineering, Nano Technology & science, Power Electronics, Electronics & Communication Engineering, Computational mathematics, Image processing, Civil Engineering, Structural Engineering, Environmental Engineering, VLSI Testing & Low Power VLSI Design etc.
Effect of variation of plastic hinge length on the results of non linear anal...eSAT Journals
Abstract The nonlinear Static procedure also well known as pushover analysis is method where in monotonically increasing loads are applied to the structure till the structure is unable to resist any further load. It is a popular tool for seismic performance evaluation of existing and new structures. In literature lot of research has been carried out on conventional pushover analysis and after knowing deficiency efforts have been made to improve it. But actual test results to verify the analytically obtained pushover results are rarely available. It has been found that some amount of variation is always expected to exist in seismic demand prediction of pushover analysis. Initial study is carried out by considering user defined hinge properties and default hinge length. Attempt is being made to assess the variation of pushover analysis results by considering user defined hinge properties and various hinge length formulations available in literature and results compared with experimentally obtained results based on test carried out on a G+2 storied RCC framed structure. For the present study two geometric models viz bare frame and rigid frame model is considered and it is found that the results of pushover analysis are very sensitive to geometric model and hinge length adopted. Keywords: Pushover analysis, Base shear, Displacement, hinge length, moment curvature analysis
Analysis and Optimum Design for Steel Moment Resisting Frames to Seismic Exci...IJCMESJOURNAL
The essential purpose of this wander is to develop an Interior Penalty Function (IPF) based estimation to multi-storey steel traces for slightest weight of frames. The frames are proposed for contradicting even impact in view of seismic stacking close by gravity forces. Various structural stems are used for restricting seismic (lateral) forces; however steel moment resisting frames (MRFs) are considered for the present work. The framework solidifies codal courses of action of IS 800-2007, as needs be gets the edges with perfect weight for in-plane moments with lateral support of beam element. Strength and buckling criteria are considered as direct goals close by side constraints in formulating optimization problem. A Software program is made that uses an interior penalty function (IPF) for weight minimization of two-dimensional moment restricting steel encompassed structures. The program uses MATLAB, performs one dimensional interest, and structural design in an iterative technique. The design cases have exhibited that the proposed estimation gives a beneficial instrument to the practicing fundamental algorithm. The program is associated with 6 and 9 storey (4 bays) moment resisting frames (MRFs). The program showed its capacity of optimizing the largeness of two medium size frames. To get part obliges in frames an examination technique must be associated. In the present work Equivalent Lateral Force framework (ELF) and material nonlinear time history analysis (NTH) are associated and perfect qualities gained from both the examinations are contemplated.
Seismic performance of r c buildings on sloping grounds with different types ...eSAT Journals
Abstract
Structure are highly susceptible to serve damages in earthquake scenario, so choosing an appropriate lateral force resisting
bracing systems will have a significant effect on performance of the structure. So this present study is aimed at evaluating and
comparing various types of eccentric steel bracings for 12 storey RC frame building resisting on sloping ground configurations.
For this 5 types of bracing systems like X-Bracing, Diagonal bracing, K- bracing, V-bracing and inverted V bracing are
considered on the outer periphery of the buildings with step back and set back – step back type configurations are modeled and
analyzed. The models are compared for different aspects within the structure, such as the maximum storey displacement, base
shear, storey drift and storey shear, the structure is analyzed for seismic zone V and medium soil condition as per IS 1893:2002
using ETABS software. Results conclude that on sloping ground due to irregularity on ground surface, the structures are more
vulnerable to earthquakes. Hence use of eccentric steel bracing is an effective and economical way to resist earthquake forces,
Inverted V type bracing performs well compared to other bracing types. By using inverted V type bracing in step back buildings
types maximum storey displacement of 70% and storey drift of 66% are obtained. Similarly for setback – step back configuration
maximum storey displacement of 74% and storey drift of 70% are obtained respectively.
Keywords: X-Bracing, Diagonal Bracing, K- Bracing, V-Bracing and Inverted V Bracing
Non linear static pushover analysis of irregular space frame structure with a...eSAT Publishing House
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Saudi Arabia stands as a titan in the global energy landscape, renowned for its abundant oil and gas resources. It's the largest exporter of petroleum and holds some of the world's most significant reserves. Let's delve into the top 10 oil and gas projects shaping Saudi Arabia's energy future in 2024.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Welcome to WIPAC Monthly the magazine brought to you by the LinkedIn Group Water Industry Process Automation & Control.
In this month's edition, along with this month's industry news to celebrate the 13 years since the group was created we have articles including
A case study of the used of Advanced Process Control at the Wastewater Treatment works at Lleida in Spain
A look back on an article on smart wastewater networks in order to see how the industry has measured up in the interim around the adoption of Digital Transformation in the Water Industry.
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/