The MagWave features two separate close-coupled chambers for the level indicator float and the Guided Wave Radar antenna. Using single probe radar transmitters in the standard 1-1/2 inch chamber provides the measurement capabilities of coaxial style probes without the potential for fouling due to buildup. The separate float chamber allows the float to travel unobstructed throughout the range of measurement. Redundant level control can be achieved by adding a magnetostrictive transmitter or switches to the float chamber.
Design and Safety Requirementsfor Liquefied Petroleum Gas Mounded Storage Facility.
This standard lays down minimum requirements on safety, design, layout, installation, operation, maintenance and testing of aboveground fully mounded bulk vessels used for storage of Liquefied Petroleum Gas (LPG) installed in the refineries, gas processing plants, terminals, bottling plants and auto LPG dispensing stations.
Design and Safety Requirementsfor Liquefied Petroleum Gas Mounded Storage Facility.
This standard lays down minimum requirements on safety, design, layout, installation, operation, maintenance and testing of aboveground fully mounded bulk vessels used for storage of Liquefied Petroleum Gas (LPG) installed in the refineries, gas processing plants, terminals, bottling plants and auto LPG dispensing stations.
Atmospheric Storage Tank Safety is dependent on various factors. To name a few:
1. Liquid movement in and out of the tank
2. Weather condition changes
3. Fire exposure
The presentation shows a basic overview of how we can create safe environment for storage and transportation of fluids.
This presentation simplifies the key postulates of Static and Mobile Pressure Vessel Rules (2016) last amended in 2018, for the design, License, operation and maintenance of LNG storage and regasification station.
Salisbury leather protector gloves should always be worn over insulating rubber gloves to provide mechanical protection against cuts, abrasions and punctures. The Salisbury ILP series of leather protectors are made from top grain cowhide or goatskin.
Cowhide cuffs are tough leather on the palm side of the protector glove and orange vinyl on the back. The goatskin cuffs are green leather on the palm of the glove and orange vinyl on the back. Salisbury ILP10 leather protector gloves do not have a cuff.
Salisbury leather protector gloves are available in dual sizes and the Salisbury Class 0 and Class 00 gloves are also available with a non-metallic buckle and pull strap or elastic wrist.
Salisbury Leather Protector Gloves For Rubber Insulating Gloves
NOTE: Do not use leather protector gloves alone for protection against electric shock. ALWAYS use proper insuating rubber gloves. Remember to inspect the leather protectors when inspecting the rubber insulating gloves.
The revolutionary Water-Mist technology. Low Pressure & High Pressure Water-Mist. Design calculations, Standards, Applications, Limitations. Alternative to Gas suppression - sprinkler systems.
Contact: 95949-66462
PREMIUM BOOK WITH HIGH DEFINITION QUALITY.
**A complete Guide of Fire fighting System.**
This HANDBOOK has been made from references of many books from all over the world. Which has been collected in one book.
1. Sprinkler system Type
WET PIPE SPRINKLER SYSTEM
DRY PIPE SPRINKLER SYSTEM
PRE-ACTION SYSTEM
DELUGE SYSTEM
WET PIPE ANTI FREEZE SYSTEM
FOAM WATER SPRINKLER SYSTEM
2. Sprinkler Selection
3 . Piping
4. Hydraulic Calculation
5. Standpipe System
6. Pump Selection & Types
Foxboro Magnetic Flowmeter for Chemical and Process IndustriesSwanson Flo
Based on Faraday’s law of induction, Foxboro magnetic meters are a reliable ow measurement solution with a lower cost of ownership and maintenance, as well as eld-proven stability to maximize the availability of ow measurement.
With a wide range of liners and electrodes, the 9700A owtube is ideal for the Chemical and Process industries. In combination with the IMT30A, IMT31A and IMT33A transmitters, Foxboro offers an innovative solution designed to meet the demands for all chemical applications such as:
• Clean liquids
• Mixing of chemicals
• Demanding applications including corrosive, abrasive liquids • Rapid variation of the pH value
• For slurries and pastes with high solids content
• Drilling applications, mining slurries with large particles
The Brooks® Ar-MiteTM is a reliable, low flow metal tube flowmeter with 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication. This model is a practical and economical approach to low flow rate indication for high pressure and difficult to handle fluids. Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
Atmospheric Storage Tank Safety is dependent on various factors. To name a few:
1. Liquid movement in and out of the tank
2. Weather condition changes
3. Fire exposure
The presentation shows a basic overview of how we can create safe environment for storage and transportation of fluids.
This presentation simplifies the key postulates of Static and Mobile Pressure Vessel Rules (2016) last amended in 2018, for the design, License, operation and maintenance of LNG storage and regasification station.
Salisbury leather protector gloves should always be worn over insulating rubber gloves to provide mechanical protection against cuts, abrasions and punctures. The Salisbury ILP series of leather protectors are made from top grain cowhide or goatskin.
Cowhide cuffs are tough leather on the palm side of the protector glove and orange vinyl on the back. The goatskin cuffs are green leather on the palm of the glove and orange vinyl on the back. Salisbury ILP10 leather protector gloves do not have a cuff.
Salisbury leather protector gloves are available in dual sizes and the Salisbury Class 0 and Class 00 gloves are also available with a non-metallic buckle and pull strap or elastic wrist.
Salisbury Leather Protector Gloves For Rubber Insulating Gloves
NOTE: Do not use leather protector gloves alone for protection against electric shock. ALWAYS use proper insuating rubber gloves. Remember to inspect the leather protectors when inspecting the rubber insulating gloves.
The revolutionary Water-Mist technology. Low Pressure & High Pressure Water-Mist. Design calculations, Standards, Applications, Limitations. Alternative to Gas suppression - sprinkler systems.
Contact: 95949-66462
PREMIUM BOOK WITH HIGH DEFINITION QUALITY.
**A complete Guide of Fire fighting System.**
This HANDBOOK has been made from references of many books from all over the world. Which has been collected in one book.
1. Sprinkler system Type
WET PIPE SPRINKLER SYSTEM
DRY PIPE SPRINKLER SYSTEM
PRE-ACTION SYSTEM
DELUGE SYSTEM
WET PIPE ANTI FREEZE SYSTEM
FOAM WATER SPRINKLER SYSTEM
2. Sprinkler Selection
3 . Piping
4. Hydraulic Calculation
5. Standpipe System
6. Pump Selection & Types
Foxboro Magnetic Flowmeter for Chemical and Process IndustriesSwanson Flo
Based on Faraday’s law of induction, Foxboro magnetic meters are a reliable ow measurement solution with a lower cost of ownership and maintenance, as well as eld-proven stability to maximize the availability of ow measurement.
With a wide range of liners and electrodes, the 9700A owtube is ideal for the Chemical and Process industries. In combination with the IMT30A, IMT31A and IMT33A transmitters, Foxboro offers an innovative solution designed to meet the demands for all chemical applications such as:
• Clean liquids
• Mixing of chemicals
• Demanding applications including corrosive, abrasive liquids • Rapid variation of the pH value
• For slurries and pastes with high solids content
• Drilling applications, mining slurries with large particles
The Brooks® Ar-MiteTM is a reliable, low flow metal tube flowmeter with 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication. This model is a practical and economical approach to low flow rate indication for high pressure and difficult to handle fluids. Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
Cameron's CamCor™ PRO Series Coriolis flow meter features high-accuracy, shallow bow-shaped dual sensor tubes and is ideal for oilfield production applications. This industrial process-grade Coriolis flow meter offers high performance for accuracy, repeatability, wide flow range, low pressure loss, and safe design.
Magnetrol Guide Wave Radar Level Transmitter For Hygienic ApplicationsMiller Energy, Inc.
For hygienic applications, the transmitters are available with a 304 stainless steel housings designed specifically for use in facilities with the special requirements for the wetted and non-wetted materials, process connections and surface finishes of hygienic industries.
Explosion Proof/Flame Proof (Ex D) Sensors for Hazardous Area Now Available i...Ives Equipment
Macnaught’s Positive Displacement Flow Meters are suitable for a wide range of industrial applications including fuel and oil distribution, corrosive chemical, solvent measurement and high pressure applications to name a few.
Macnaught is proud to now extend its range of pulse output options to include Ex D flame proof approved sensors for hazardous areas.
The Marechal DXN Plug and Socket Outlets (decontactors) comply with ATEX Hazardous Area Certification for use in Explosive Atmospheres including Zones 1 and 2 (gas) and Zones 21 and 22 (dust).
Marechal DXN ATEX certified hazardous area plugs and sockets are rated from 20-63amps, IP66/67 watertight ingress protection and with socket-outlet safety shutter providing IP4X protection. The Marechal DXN plugs and sockets also comply with EN 50018 (explosion proof safety "d") EN 50019 (increased safety "e"), EN 50281-1-1 (electrical equipment for use in flammable dust atmospheres) and IEC 60309-1 (plugs and socket-outlets for industrial purposes) standards.
Dienhathe.com miniature circuit breakersDien Ha The
Siemens,
Catalog Thiết Bị Điện Siemens, Catalog Thiết Bị Điện,
Catalog Phụ Kiện Siemens, Catalog Phụ Kiện,
Catalog Siemens, Catalog,
http://dienhathe.com,
Chi tiết các sản phẩm khác của Siemens tại https://dienhathe.com
Xem thêm các Catalog khác của Siemens tại https://dienhathe.info
Để nhận báo giá sản phẩm Siemens vui lòng gọi: 0907.764.966
Similar to Combination Guided Wave Radar Transmitter and Magnetic Level Gauge (20)
PID is short for "proportional plus integral and derivative control", the three actions used in managing a control loop. Process loop controllers use one, two or all three of these to optimally control the process system. PID control is used in a wide variety of applications in industrial control and process system management.
Courtesy of Eurotherm. Eurotherm offers a wide range of single & multi-loop PID controllers.
Smokeless Flares
Smokeless flares incinerate flammable hazardous vent gas with the assistance of supplemental high-velocity air or steam to prevent the formation of soot or smoke. Excessive injection of air or steam reduces combustion efficiency, resulting in the release of hazardous VOC gases. Meanwhile, inadequate injection of air or steam results in the formation of undesirable soot and smoke. Although modern flares are designed for high flow rates associated with an emergency condition, they most commonly operate at high-turn-down, low-flow rates, making it challenging for the flare to operate at optimal combustion efficiency.
Pilot Monitor
Flammable vent gases are ignited by a pilot flame when released into the atmosphere by refineries, natural gas processing plants, and petrochemical plants. The proper incineration of these gases is a critical safety and environmental concern. Therefore, it is essential to confirm that the pilot is lit at all times. Monitoring via a thermocouple is common, however, failures frequently occur and replacements can require costly process shutdowns. Remote sensing IR technology (PM) is the superior alternative.
Flame Intensity Monitors
Williamson Flame Intensity Monitors (FI) are the single-wavelength sensors of choice for a variety of flare applications where the more sophisticated dual-wavelength flare products are not appropriate or are not required.
Some materials can be difficult or near impossible to measure with precision using single-wavelength or ratio pyrometers because of their complex emissivity characteristics. These types of materials are called non-greybody materials and their emissivity varies with wavelength.
Multi-wavelength pyrometers use application specific algorithms to characterize infrared energy and emissivity across the measured wavelengths to accurately calculate both the actual temperature and emissivity of these complex non-greybody materials.
The 3000 series gives you high accuracy, fast response time and low temperature drift – without compromise. All 6 mm devices can be mounted on a standard DIN rail or power rail with no air gap separation.
Bronkhorst has over 35 years experience in designing and manufacturing precise and reliable measurement and control equipment and the widest range of mass flow and pressure meters and controllers available on the market.
Bronkhorst offers innovative solutions for many different applications across a great many different markets, and has a particular strong wealth of knowledge and reputation within the plastics and rubber market.
The Coriolis measuring principle refers to the effect that a moving mass has on a body in a rotating frame of reference. The moving mass exerts an apparent force on the body, causing a deformation. This force is called the Coriolis force. It does not act directly on the body, but on the motion of the body. This principle is used in Coriolis flowmeters.
AP Tech is a manufacturer of gas handling components – primarily pressure regulators and valves. AP Tech’s competitive advantage are products that deliver specialty gases for high purity through ultra high purity applications. Starting from the source vessel to point of use and into the process tool or equipment itself, AP Tech products are known to deliver gases with uncompromising quality, performance and reliability.
The L100 Bubble-Tube Level System is a fully self contained instrument, requiring only connections to air or gas supply, dip tube and electrical power source to provide precise level indication. Because only the stationary dip tube and the purge gas come in contact with the liquid, this system is ideal for applications involving hazardous locations or liquids which are highly corrosive, viscous, hot, (molten metal), explosive, slurry type or foodstuff.
For applications where rapid transition from open to closed positions is warranted, the Mark 76 is a solid choice. Designed with a short stroke and straight through fluid path, the Mark 76 also incorporates other features to assure good service for process operations using on/off control.
Tek-Trol provides process measurement and control products for Flow, Level, Temperature and Pressure measurement and Control Valves and Analyzers systems for the Process, Power and Oil and Gas Industries.
EL-FLOW Prestige is the next generation of Bronkhorst Mass Flow Meters / Controllers for gases. Nearly all core components have been redesigned and many improvements and innovations have been incorporated. With this new series Bronkhorst introduced the “Differential Temperature Balancing” technology, ensuring a superb sensor stability.
Each ReFlexIO unit allows you to connect (2) Analog Inputs and (2) Digital Inputs which are wirelessly transferred to (2) Analog Outputs and (2) Digital Outputs on the other end. The 2 ReFlexIO 'paired' units work bi-directionally, so it's possible, for example, to turn on a relay (digital input to digital output on the other end) and get a signal back (digital input to sense replay closure returned to digital output on the original sending unit) to turn on a light telling you that the relay is indeed on.
The T2750 PAC hardware provides high-performance control with cost-effective redundancy options in a versatile modular system. Powerful instruments, the control units, and the I/O system form the basis of a complete distributed control and recording environment. This environment is capable of continuous analog, logic, sequential control, batch management, secure data recording at point of measurement, and setpoint programming.
The T2550 PAC is a high performance solution offering extremely cost effective redundancy options - making high availability viable for more of your process.
The control unit and I/O system form the basis of a complete distributed control and recording environment capable of continuous analog, logic and sequential control combined with secure data recording at point of measurement - all designed to maximize Return on Investment (ROI) from your process.
ControlAir Inc. is a leading manufacturer of precision air pressure regulators, I/P transducers, E/P transducers, P/I transducers, valve positioners, air relays, volume boosters, air filter regulators and frictionless diaphragm air cylinders.
The LowFlow JRDL Series line of diaphragm sensed, high pressure regulators have the ability to handle very high pressures and very low flows. These valves are typically used in research and sampling systems for general, corrosive and specialty gas and liquid service. Typical applications include gas chromatography and flame ionization detectors, as well as other industrial controls.
The Model TCL measures total chlorine in water, and is ideal for seawater chlorine analysis applications. The system consists of a sample conditioning unit, a sensor, and transmitter
The EL2200 series of electromagnetic flowmeters represent the state of the art for the accurate measurement for water cycle and process applications. This new generation flowmeter utilizes an innovative structure to route the electromagnetic signal generated by the electrodes, providing a flowmeter with an extremely wide measurement range. The new EL Series meters are capable of a measurement range up to 1000:1.
The new PowerVUE™ design utilizes the same rugged Hagan actuator and frame construction, combined with the accuracy and reliability of the Fisher FieldVUE DVC6000 Digital Valve Controller. The pneumatic power positioner remains the most reliable and cost-effective method of actuation. Torque ranges are from 400 ft-lbs to 4,600 ft.-lbs.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Vaccine management system project report documentation..pdfKamal Acharya
The Division of Vaccine and Immunization is facing increasing difficulty monitoring vaccines and other commodities distribution once they have been distributed from the national stores. With the introduction of new vaccines, more challenges have been anticipated with this additions posing serious threat to the already over strained vaccine supply chain system in Kenya.
Industrial Training at Shahjalal Fertilizer Company Limited (SFCL)MdTanvirMahtab2
This presentation is about the working procedure of Shahjalal Fertilizer Company Limited (SFCL). A Govt. owned Company of Bangladesh Chemical Industries Corporation under Ministry of Industries.
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
Automobile Management System Project Report.pdfKamal Acharya
The proposed project is developed to manage the automobile in the automobile dealer company. The main module in this project is login, automobile management, customer management, sales, complaints and reports. The first module is the login. The automobile showroom owner should login to the project for usage. The username and password are verified and if it is correct, next form opens. If the username and password are not correct, it shows the error message.
When a customer search for a automobile, if the automobile is available, they will be taken to a page that shows the details of the automobile including automobile name, automobile ID, quantity, price etc. “Automobile Management System” is useful for maintaining automobiles, customers effectively and hence helps for establishing good relation between customer and automobile organization. It contains various customized modules for effectively maintaining automobiles and stock information accurately and safely.
When the automobile is sold to the customer, stock will be reduced automatically. When a new purchase is made, stock will be increased automatically. While selecting automobiles for sale, the proposed software will automatically check for total number of available stock of that particular item, if the total stock of that particular item is less than 5, software will notify the user to purchase the particular item.
Also when the user tries to sale items which are not in stock, the system will prompt the user that the stock is not enough. Customers of this system can search for a automobile; can purchase a automobile easily by selecting fast. On the other hand the stock of automobiles can be maintained perfectly by the automobile shop manager overcoming the drawbacks of existing system.
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
Forklift Classes Overview by Intella PartsIntella Parts
Discover the different forklift classes and their specific applications. Learn how to choose the right forklift for your needs to ensure safety, efficiency, and compliance in your operations.
For more technical information, visit our website https://intellaparts.com
Immunizing Image Classifiers Against Localized Adversary Attacksgerogepatton
This paper addresses the vulnerability of deep learning models, particularly convolutional neural networks
(CNN)s, to adversarial attacks and presents a proactive training technique designed to counter them. We
introduce a novel volumization algorithm, which transforms 2D images into 3D volumetric representations.
When combined with 3D convolution and deep curriculum learning optimization (CLO), itsignificantly improves
the immunity of models against localized universal attacks by up to 40%. We evaluate our proposed approach
using contemporary CNN architectures and the modified Canadian Institute for Advanced Research (CIFAR-10
and CIFAR-100) and ImageNet Large Scale Visual Recognition Challenge (ILSVRC12) datasets, showcasing
accuracy improvements over previous techniques. The results indicate that the combination of the volumetric
input and curriculum learning holds significant promise for mitigating adversarial attacks without necessitating
adversary training.
Immunizing Image Classifiers Against Localized Adversary Attacks
Combination Guided Wave Radar Transmitter and Magnetic Level Gauge
1. MW05 MagWave
Magnetic Level Gauge
Data sheet DS/MW05-EN Rev. C
Dual chamber level system
K-TEK Products
Multiple Chamber Styles
–– 24 Preconfigured Styles Plus Custom Styles
–– Left Hand or Right Hand Mounted Secondary Chambers
–– Capped or Flanged Secondary Chamber Connections
–– 2, 3, or Multiple Process Connections
Secondary Chamber Sizes to Suit the Application
–– 1-1/2 inch Schedule 10 Standard
–– 2, 2-1/2, 3 and 4 inch Sizes
–– Schedule 10, 40 or 80 Welded or Seamless
Variety of Chamber Materials
–– 304SS, 316SS, Hastelloy C-276, Alloy 20, Other Non-
magnetic Metals
–– Teflon “S” Coated Chambers for Slip Resistance.
Chamber Configurations to Fit Process Connections
–– Custom Manufactured for Every Installation
–– Side - Side
–– Top - Side
–– Side - Bottom
–– Top - Bottom
Unlimited Range of Connection Sizes and Ratings
–– 1/2 inch Threaded Half Couplings to 2-1/2 inch 1500#
Flanges and Beyond
–– ANSI, DIN and Other Flanges
–– Matched to Customer Specified Connections
–– Carbon Steel Flanges on Stainless Steel Chambers
Highly Visible Indicators
–– Fluorescent and High Temperature Shuttle Indicators
–– Yellow & Black Magnetic Bargraphs
–– Red & White Magnetic Bargraphs
Made to Order Rulers
–– Foot and Inch
–– Running Inches
–– Negative to Positive Numbering
–– Meter / centimeter
–– Custom Made for Percent or Volume
Custom Built Lengths
–– Connection Centers to 40 feet (12.2 meters)
–– No “Off the Shelf” systems
–– Full Measurement Range
Accessories
–– Magnetically Actuated Switches
–– Magnetostrictive Transmitters
–– High Temperature Insulation Blankets
–– Cryogenic Insulation
–– Vent, Drain, and Isolation Valves
–– Electric and Steam Tracing
2. 2 MW05 Magnetic Level Gauge | Data sheet
Featuring Guided Wave Radar Transmitters
Secondary Chamber
Elbow Drain Connection
Highly Visible Magnetically
Coupled Indicator
Single Probe
Guided Wave Radar
Transmitter
Standard 1-1/2 inch
Secondary Chamber
Compact Close Coupled Chambers
Extruded Outlet
Connections
Compact Footprint
ASME
B31.1, B31.3
Model MW0513
3. Data sheet | MW05 Magnetic Level Gauge 3
No Need For Coaxial Probes
•• A Single Probe in the 1-1/2 inch Secondary Chamber
provides the same measurement capabilities as a coaxial
probe
•• The small internal space of a coaxial style probe is very
susceptible to fouling in dirty fluid
•• Coaxial probes have small holes that are prone to fouling
causing false level readings
•• If the single probe does encounter build up, it can be easily
removed from the chamber for cleaning
Why Separate Chambers?
Putting a GWR and a float in a single chamber requires larger
pipe sizes, larger flange sizes, and a separation plate between
the float and the GWR coaxial probe.
Single Chambers result in:
•• Extra parts in the float chamber which can obstruct float travel
•• Increased “footprint” of the entire system
•• Increased cost of the system
•• Increased weight of the system
•• Remote mounting of GWR electronics when top connections to the system are required
•• Limited access to the float’s magnetic field
Large Chamber
(3 inch minimum)
GWR Coaxial Probe
Extra
Separation Plate
Small
Magnetic Field
Float
Oversized Single Chamber System
Float
GWR Single Probe
Small Float
Chamber
1-1/2 inch
GWR
Chamber
Large
Magnetic Field
Compact Dual Chamber System
2.194 in2
inside
MagWave Standard
1-1/2” Sch 10 and 3/16” cable
(no spacers required)
Coaxial Probe
(with spacers)
0.387 in2
inside
Actual Size Shown
MagWave
4. 4 MW05 Magnetic Level Gauge | Data sheet
MagWave
Multiple Wetted Part Materials
•• Standard 316SS
•• Hastelloy C-276
•• Hastelloy B3
•• Monel
•• Titanium
Couplers Suited to the Process
•• Standard
1500 psi @ 100 F (103bar @ 38 C)
600 psi @ 400 F (41 bar @ 204 C)
•• High Pressure
3000 psi @ 100 F (207bar @ 38 C)
1200 psi @ 400 F (83bar @ 204 C)
•• High Pressure/Temperature
5000 psi @ 100 F (344bar @ 38 C)
1500 psi @ 800 F (103bar @ 427 C)
•• Saturated Steam
2000 psi @ 635 F (138bar @ 335 C)
Modular Electronics
•• LCD Display
•• HART Communications
•• Honeywell DE
•• Level and Interface Measurement
Guided Wave Radar
MagWave with
Valves Installed
MS30/EX SPDT 1 AMP Switch MS41 DPDT 10 AMP Switch
5. Data sheet | MW05 Magnetic Level Gauge 5
AT100
•• Magnetostrictive Transmitter
•• LCD Display
•• HART Communications
•• Honeywell DE
•• Foundation Fieldbus
•• FM, CSA, ATEX approvals
•• Level and Interface Measurement
A38
•• Capacitance Transmitter
•• Magnet Calibration
•• FM and CSA approvals
•• Level or Interface Measurement
•• Low Cost Transmitter
•• Rod and Cable Probes
For Detailed Specifications and Ordering Information Consult the MagWave Configuration Guide COI/MW05-EN.
C2 Coupler
P12 Probe
Dual Compartment Housings
•• Powder Coated Aluminum Standard
•• Stainless Steel
•• Solid Covers or Viewing Windows
•• Built in RFI Protection
Single Probe Waveguides
•• 3/16 inch Cables
•• 1/4 inch and 1/2 inch Rigid Rods
Hazardous Area Approvals
•• FM Factory Mutual
XP / I / 1 / ABCD / T6 Ta = 77C
DIP / II, III / 1 / EFG / T6 Ta = 77C
IS / I / 1 / CD / T4 Ta = 77C - ELE1014
NI / I / 2 / ABCD / T4 Ta = 77C
Type 4X
•• CSA Canadian Standards Association
XP CL I Div 1 GP ABCD
CL II GP G & Coal Dust (Exia) Associated Equip., Provides I.S. Output to Sensor
IS CL I Div 1 GP CD T4
CL I Div 2 GP ABCD
CL II Div 2 GP G & Coal Dust when installed per ELE1014
•• ATEX Flameproof
II 1/2 GD EExd IIC T6 (80°C) Tamb +66°C;
02 ATEX 131713
•• ATEX Intrinsically Safe
II 1 GD EEx ia IIB T6 (80°C) Tamb +66°C;
02 ATEX 131712
Alternate Transmitters