Cameron's CamCor™ PRO Series Coriolis flow meter features high-accuracy, shallow bow-shaped dual sensor tubes and is ideal for oilfield production applications. This industrial process-grade Coriolis flow meter offers high performance for accuracy, repeatability, wide flow range, low pressure loss, and safe design.
Azbil North America recently added the AX series of multivariable vortex flowmeters for industrial process measurement and control to their product offering. The instrument combines temperature, pressure and velocity measurement in a single instrument to provide accurate mass flow measurement of gases, liquids and steam.
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest
possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can be configured to meet individual requirements.
The FLUXUS® flowmeter series includes a variety of transmitters
and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous areas.
The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity.
As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all-welded sensor design to create a strong unit and minimize potential leakage.
The AX Series can be configured to measure anything from simple volumetric flow of liquids and saturated steam up through multivariable measurements, including mass flow rate, pressure, temperature and density of liquids and steam.
Insertion style vortex meters measure fl ow by detecting the local velocity at a strategically located position within the pipe. Using local velocity, calculated by measuring the rate at which vortices are alternately shed from a bluff body within the sensor, the AX2300 uses parameters such as fluid type, pipe size, and Reynolds number to calculate accurate measurements.
Pulp and paper applications create a notoriously harsh, high moisture and chemical-laden environment; coupled with extreme vibration in many of the processes. The following document outlines an array of level, pressure, and position applications and solutions for the pulp & paper industry.
Inline and Insertion models of the Azbil Multivariable Vortex Mass Flow Meters employ three sensing elements in a single meter; a vortex shedding velocity sensor, an RTD temperature sensor, and a solid state pressure transducer. This unique combination allows accurate mass flow measurements of gases, liquids and steam.
Azbil North America recently added the AX series of multivariable vortex flowmeters for industrial process measurement and control to their product offering. The instrument combines temperature, pressure and velocity measurement in a single instrument to provide accurate mass flow measurement of gases, liquids and steam.
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Clamp-on technology provides for maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest
possible accuracy and reliability. The measuring system, consisting of the transmitter, the transducers and the VARIOFIX mounting fixture, can be configured to meet individual requirements.
The FLUXUS® flowmeter series includes a variety of transmitters
and transducers: from basic models for standard applications up to robust measurement solutions for offshore use or for hazardous areas.
The AX Series of Vortex inline flowmeters measure flows of liquid, gas, and steam by measuring the rate at which vortices are alternately shed from a bluff body; this rate has been shown to be directly proportional to the flow velocity.
As flow passes a bluff body in the stream, vortices create pressure differentials which are measured by a piezoelectric crystal sensor, which converts these pulses into electrical signals. The meter uses an all-welded sensor design to create a strong unit and minimize potential leakage.
The AX Series can be configured to measure anything from simple volumetric flow of liquids and saturated steam up through multivariable measurements, including mass flow rate, pressure, temperature and density of liquids and steam.
Insertion style vortex meters measure fl ow by detecting the local velocity at a strategically located position within the pipe. Using local velocity, calculated by measuring the rate at which vortices are alternately shed from a bluff body within the sensor, the AX2300 uses parameters such as fluid type, pipe size, and Reynolds number to calculate accurate measurements.
Pulp and paper applications create a notoriously harsh, high moisture and chemical-laden environment; coupled with extreme vibration in many of the processes. The following document outlines an array of level, pressure, and position applications and solutions for the pulp & paper industry.
Inline and Insertion models of the Azbil Multivariable Vortex Mass Flow Meters employ three sensing elements in a single meter; a vortex shedding velocity sensor, an RTD temperature sensor, and a solid state pressure transducer. This unique combination allows accurate mass flow measurements of gases, liquids and steam.
Magnetic flow meter for industrial process measurementCTi Controltech
Enhanced signal conditioning circuitry provides excellent noise and spike immunity
High stable and repeatable output with ±0.5% of rate accuracy
Minimum process fluid conductivity requirement of 10μS/cm provides maximum applicability
Electrode Status Diagnostic function diagnoses empty pipe condition or electrode scaling
Available in wafer of flanged designs
Both Integral and Remote configurations are available for maximum flexibility
Making the best instrument selection for a flow measurement application should include an assessment of what the operators really need in order to safely and effectively run the process or perform the task related to the measurement of fluid flow.
The FLUXUS G704 is FLEXIM's gas flow meter for permanent installation in nearly any gas flow metering application. Its non-intrusive measurement technology ensures a precise bi-directional, highly dynamic gas flow measurement of operational and standard volume flows.
The Brooks® Ar-MiteTM is a reliable, low flow metal tube flowmeter with 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication. This model is a practical and economical approach to low flow rate indication for high pressure and difficult to handle fluids. Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
Magnetrol International has launched the PULSAR Model R86 Non-Contact Radar transmitter, an advanced level control solution that offers radar technology with improved performance for a wide range of level measurement applications.
The PULSAR Model R86 is designed to provide
outstanding accuracy, reliability and safety for
virtually all process industries.
Receive information on transformer fault situations with reliable and robust online transmitter. The Vaisala Moisture, Hydrogen and Temperature Transmitter MHT410 for Transformer Oil measures directly from representative transformer oil giving both reliable hydrogen trend as well as fast moisture data.
It is built to last and doesn’t have wearing parts such as membrane, pumps, hoses or batteries. Easy to install, the MHT410 is ready to use within minutes. Continuously monitoring hydrogen and moisture levels with an in-situ probe is the first step in extending the life of a transformer through implementation of predictive maintenance practices leading to lower total cost of ownership.
Magnetic flow meter for industrial process measurementCTi Controltech
Enhanced signal conditioning circuitry provides excellent noise and spike immunity
High stable and repeatable output with ±0.5% of rate accuracy
Minimum process fluid conductivity requirement of 10μS/cm provides maximum applicability
Electrode Status Diagnostic function diagnoses empty pipe condition or electrode scaling
Available in wafer of flanged designs
Both Integral and Remote configurations are available for maximum flexibility
Making the best instrument selection for a flow measurement application should include an assessment of what the operators really need in order to safely and effectively run the process or perform the task related to the measurement of fluid flow.
The FLUXUS G704 is FLEXIM's gas flow meter for permanent installation in nearly any gas flow metering application. Its non-intrusive measurement technology ensures a precise bi-directional, highly dynamic gas flow measurement of operational and standard volume flows.
The Brooks® Ar-MiteTM is a reliable, low flow metal tube flowmeter with 316L stainless steel wetted parts. The magnetically coupled indicator provides a highly reliable method of indication. This model is a practical and economical approach to low flow rate indication for high pressure and difficult to handle fluids. Optional accessories include 4-20 mA output, Needle Valve, Flow Controllers and Alarms.
Magnetrol International has launched the PULSAR Model R86 Non-Contact Radar transmitter, an advanced level control solution that offers radar technology with improved performance for a wide range of level measurement applications.
The PULSAR Model R86 is designed to provide
outstanding accuracy, reliability and safety for
virtually all process industries.
Receive information on transformer fault situations with reliable and robust online transmitter. The Vaisala Moisture, Hydrogen and Temperature Transmitter MHT410 for Transformer Oil measures directly from representative transformer oil giving both reliable hydrogen trend as well as fast moisture data.
It is built to last and doesn’t have wearing parts such as membrane, pumps, hoses or batteries. Easy to install, the MHT410 is ready to use within minutes. Continuously monitoring hydrogen and moisture levels with an in-situ probe is the first step in extending the life of a transformer through implementation of predictive maintenance practices leading to lower total cost of ownership.
KwikSense smart digital gas transmitter is a field mountable device suitable for the detection and continuous monitoring of hazardous gases at industrial plant locations. Apart from providing RS-485 MODBUS-RTU digital output signal, that can be connected to a suitable control system, such as a Uniphos controller, DCS, PLC, etc, it also provides an industry standard 4-20 mA analog output. KwikSense is available for a large number of gases which include Oxygen, toxic gases, combustible gases & VOC.
Process control Solutions (PCS) offers the finest selection of Industrial Instrumentation and Control products in the world, and is uniquely qualified to provide application / technical support, installation and calibration services and product selection from an extensive line of industries.
Foxboro Magnetic Flowmeter for Chemical and Process IndustriesSwanson Flo
Based on Faraday’s law of induction, Foxboro magnetic meters are a reliable ow measurement solution with a lower cost of ownership and maintenance, as well as eld-proven stability to maximize the availability of ow measurement.
With a wide range of liners and electrodes, the 9700A owtube is ideal for the Chemical and Process industries. In combination with the IMT30A, IMT31A and IMT33A transmitters, Foxboro offers an innovative solution designed to meet the demands for all chemical applications such as:
• Clean liquids
• Mixing of chemicals
• Demanding applications including corrosive, abrasive liquids • Rapid variation of the pH value
• For slurries and pastes with high solids content
• Drilling applications, mining slurries with large particles
GCEM 40 series gas analyser insitu-codel datasheetENVIMART
GCEM 40 series gas analyser insitu-codel datasheet - CODEL - Envimart JSC - www.envimart.vn - ĐT: 028 77727979 - sales@envimart.vn - Nền tảng cung cấp thiết bị, vật tư ngành nước và môi trường.
The MagWave features two separate close-coupled chambers for the level indicator float and the Guided Wave Radar antenna. Using single probe radar transmitters in the standard 1-1/2 inch chamber provides the measurement capabilities of coaxial style probes without the potential for fouling due to buildup. The separate float chamber allows the float to travel unobstructed throughout the range of measurement. Redundant level control can be achieved by adding a magnetostrictive transmitter or switches to the float chamber.
Designed to provide thorough, continuous monitoring of many hazardous gases, the indoor/outdoor Ultima X Series Gas Monitors offer excellent performance and MSA quality craftsmanship. DuraSource™ Technology offers extended sensor life, while HART provides convenient setup, calibration and diagnostics. HART also allows for existing component install and wiring to be used. A single circuit board increases reliability, while our patented sensor disconnect-underpower feature allows all sensors to be replaced in hazardous areas without area declassification. The units are crafted from either stainless steel or polycarbonate, and the interchangeable smart sensors eliminate the need for reconfiguration. Our scrolling LCD screen display sensor reading and gas type, while the calibration process includes date stamping and the ability to calibrate locally or remotely.
Drager PointGard 2000 Series Gas Detection SystemFlow-Tech, Inc.
The Drager PointGard® 2000 series is a self-contained gas detection system for the continuous area monitoring of toxic or flammable gases in ambient air. PointGard® 2000’s rugged, water-resistant enclosure comes complete with a horn and strobes, a built-in power supply, and reliable DragerSensor®.
We have now introduced a new type of primary flow sensor & smart flow transmitter in their electromagnetic flow meter series. This sensor works on Faraday’s law of electromagnetic induction. The meter is a true volume measuring meter. The measurement is independent of Viscosity, Density, Dissolved/Un-dissolved solids, pressure, or temperature of the flowing liquid as long as it maintains certain minimum conductivity.
This flow meter is field configurable and hence it is easier to change the range on the field.
Similar to Coriolis Flow Meter - Cameron Camcor Brand (20)
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Water scarcity is the lack of fresh water resources to meet the standard water demand. There are two type of water scarcity. One is physical. The other is economic water scarcity.
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.
Cosmetic shop management system project report.pdfKamal Acharya
Buying new cosmetic products is difficult. It can even be scary for those who have sensitive skin and are prone to skin trouble. The information needed to alleviate this problem is on the back of each product, but it's thought to interpret those ingredient lists unless you have a background in chemistry.
Instead of buying and hoping for the best, we can use data science to help us predict which products may be good fits for us. It includes various function programs to do the above mentioned tasks.
Data file handling has been effectively used in the program.
The automated cosmetic shop management system should deal with the automation of general workflow and administration process of the shop. The main processes of the system focus on customer's request where the system is able to search the most appropriate products and deliver it to the customers. It should help the employees to quickly identify the list of cosmetic product that have reached the minimum quantity and also keep a track of expired date for each cosmetic product. It should help the employees to find the rack number in which the product is placed.It is also Faster and more efficient way.
Overview of the fundamental roles in Hydropower generation and the components involved in wider Electrical Engineering.
This paper presents the design and construction of hydroelectric dams from the hydrologist’s survey of the valley before construction, all aspects and involved disciplines, fluid dynamics, structural engineering, generation and mains frequency regulation to the very transmission of power through the network in the United Kingdom.
Author: Robbie Edward Sayers
Collaborators and co editors: Charlie Sims and Connor Healey.
(C) 2024 Robbie E. Sayers
CFD Simulation of By-pass Flow in a HRSG module by R&R Consult.pptxR&R Consult
CFD analysis is incredibly effective at solving mysteries and improving the performance of complex systems!
Here's a great example: At a large natural gas-fired power plant, where they use waste heat to generate steam and energy, they were puzzled that their boiler wasn't producing as much steam as expected.
R&R and Tetra Engineering Group Inc. were asked to solve the issue with reduced steam production.
An inspection had shown that a significant amount of hot flue gas was bypassing the boiler tubes, where the heat was supposed to be transferred.
R&R Consult conducted a CFD analysis, which revealed that 6.3% of the flue gas was bypassing the boiler tubes without transferring heat. The analysis also showed that the flue gas was instead being directed along the sides of the boiler and between the modules that were supposed to capture the heat. This was the cause of the reduced performance.
Based on our results, Tetra Engineering installed covering plates to reduce the bypass flow. This improved the boiler's performance and increased electricity production.
It is always satisfying when we can help solve complex challenges like this. Do your systems also need a check-up or optimization? Give us a call!
Work done in cooperation with James Malloy and David Moelling from Tetra Engineering.
More examples of our work https://www.r-r-consult.dk/en/cases-en/
Student information management system project report ii.pdfKamal Acharya
Our project explains about the student management. This project mainly explains the various actions related to student details. This project shows some ease in adding, editing and deleting the student details. It also provides a less time consuming process for viewing, adding, editing and deleting the marks of the students.
1. CamCor Coriolis Flow Meters
CT and PRO Series, for all custody transfer and process applications
2. CamCor™
CT Series Coriolis Flow Meter
Specifically Designed for Custody Transfer Applications
Precision accuracy, dual deep “U” sensor tubes, Cameron’s top-of-the-line
Coriolis flow meter offers highest performance for accuracy, repeatability,
wide flow range, low pressure loss, and safe design.
Features
• Deep “U” shaped dual sensors maximize accuracy
• Flow rate turndown up to 200:1
• Transmitters available as integral or remote-mounted
• Low-temperature models suitable for cryogenic fluids, such as LNG
• High-temperature models suitable for temperatures over 600˚ F (315˚ C)
• Extensive I/O count, including dual independent pulse outs, dual independent
analog outs, status in, and status out
• Communications: Modbus®
RS-485 and HART®
compliant
• Easy configuration via infrared sensors or EZ-Link interface software
• Self-diagnostic display – informs user of potential problems
• Diagnostic check for pipeline vibration and media pulsation
CamCor CT Coriolis Flow Meter
Model
CC00A, CC001, CC003, CC006, CC010, CC015, CC025, CC040, CC050, CC080, CC100,
CC150, CC15H, CC200, CC20H, CC250
Nominal Connection Size 1/4, 3/8, 1/2”, 3/4, 1”, 1.5”, 2”, 3”, 4”, 6”, 8”, 10”
Process Connection Types
(Depends on Sensor Size)
ANSI Flanges – 150#, 300#, 600#, 900# RF RTJ
DIN PN 10, 16, 25, 40RF; Ferrule/Tri Clover; Threaded
Acceptable Media Liquids, Gases
Nominal Flow Range
(Consult General Specs for Details)
CC00A: 0-5.3 lbm/hr (0-0.63 GPH); 0-2.4 kg/hr (0-2.4 L/hr)
CC250: 0-3,086,000 lbm/hr (0-211,522 BPD); 0-1,400,000 kg/hr (0-33,629 m3/hr)
Flow Rate Uncertainty
Liquids +/- 0.1% of Reading (+/- Zero Stability Error)
Gases +/- 0.5% of Reading (+/- Zero Stability Error)
Density Uncertainty +/- 0.0005 g/ml (CC003 thru CC250)
Operating Temps
Standard Sensor
-4˚ F to 194˚ F (-20˚ C to 90˚ C) Process Temp with Integral transmitter;
-40˚ F to 392˚ F (-40˚ C to 200˚ C) Process Temp with Remote transmitter
High Temp Sensor -4˚ F to 662˚ F (-20˚ C to 350˚ C) Process Temp with Remote transmitter
Low Temp Sensor -328˚ F to 122˚ F (-200˚ C to 50˚ C) Process Temp with Remote transmitter
Transmitter -40˚ F to +131˚ F (-40˚ C to +55˚ C) Ambient Temp
Max Working Pressure Limited by Flange Rating and Wetted Materials
Wetted Materials 316/316L SST; 316/316L SST and Hastelloy Alloy C22; Hastelloy Alloy C22
Transmitter Hazardous Location Certification
(Explosion-Proof*/Flame-Proof*)
CSA C/US Class I Zone 1 Ex d ib IIB T4 Gb (Integral)
CSA C/US Class I Zone 1 Ex d [ib] IIB T6 Gb (Remote)
ATEX / IECEx II2G Ex d ib IIC T4 Gb (Integral) Pending
ATEX / IECEx II2G Ex d [ib] IIC T6 Gb (Remote) Pending
Dust-Proof/Waterproof* IP66/IP67
*Explosion-Proof, Flame-Proof, and Waterproof as defined by CEC, NEC, ATEX, IEC and CE codes.
3. CamCor™
PRO Series Coriolis Flow Meter
Ideal for Oil Field Production Applications
High accuracy, dual shallow “bow” sensor tubes. Cameron’s process-grade
Coriolis flow meter offers high performance for accuracy, repeatability, wide
flow range, low pressure loss, and safe design.
Features
• Shallow “bow” shaped dual sensors maximize accuracy
• Flow rate turndown up to 50:1
• Transmitters available as Integral or remote-mounted
• Extensive I/O count, including dual independent pulse
outs, dual independent analog outs, status in, and status out
• Communications: Modbus®
RS-485 and HART®
compliant
• Easy configuration via infrared sensors or EZ-Link interface software
• Self-diagnostic display – informs user of potential problems
• Diagnostic check for pipeline vibration and media pulsation
CamCor PRO Coriolis Flow Meter
Model CP006, CP010, CP015, CP025, CP040, CP050
Nominal Connection Size 1/2”, 1”, 1.5”, 2”
Process Connections
(Depends on Sensor Size)
ANSI Flanges – 150#, 300#, 600# RF RTJ
Ferrule/Tri Clover
Acceptable Media Liquids
Nominal Flow Range
(Consult General Specs for Details)
CP006: 0-1,323 lbm/hr (0-2.6 GPM); 0-600 kg/hr (0-11.8 L/min)
CP050: 0-105,822 lbm/hr (0-212 GPM); 0-48,000 (0-801 L/min)
Flow Rate Uncertainty +/- 0.2% of Reading (+/- Zero Stability Error)
Density Uncertainty +/- 0.003 g/ml
Operating Temps
Sensor
-40˚ F to 176˚ F (-40˚ C to 80˚ C)
Process Temp with Integral transmitter (except model CP015);
-40˚ F to 158˚ F (-40˚ C to 70˚ C)
Process Temp with Integral transmitter (model CP015);
-40˚ F to 257˚ F (-40˚ C to 125˚ C)
Process Temp with Remote transmitter
Transmitter -40˚ F to 131˚ F (-40˚ C to 55˚ C) Ambient Temp
Max Working Pressure Limited by Flange Rating and Wetted Materials
Wetted Materials 316/316L SST
Transmitter Hazardous Location
Certification
(Explosion-Proof*/Flame-Proof*)
CSA C/US Class I Zone 1 Ex d ib IIB T4 Gb (Integral)
CSA C/US Class I Zone 1 Ex d [ib] IIB T6 Gb (Remote)
ATEX / IECEx II2G Ex d ib IIB T4 Gb (Integral) Pending
ATEX / IECEx II2G Ex d [ib] IIC T6 Gb (Remote) Pending
Dust-Proof/Waterproof* IP66/IP67
*Explosion-Proof, Flame-Proof, and Waterproof as defined by CEC, NEC, ATEX, IEC and CE codes.
The Cameron logo and CamCor are Cameron’s trademarks.
MODBUS, HART, and Hastelloy are registered trademarks of Modbus Organization, Inc., FieldComm Group, and Haynes International, Inc., respectively.
VALVES MEASUREMENT
The CamCor
CT series and
PRO series Coriolis
flow meters deliver
high accuracy
and repeatability,
wide flow range, and
low pressure loss.
Large
time-stamped
event log
Assignable alarms
Displays smart
error codes
Unique vibration
and pulsation
detection
diagnostics