SlideShare a Scribd company logo
An ISO 9001:2008 Certified Company
Anjni Transformers & Switchgears
G-99 & G-3, Phase-I, UPSIDC, Khichra
Industrial Area, Masuri-Gulawati Road,
Ghaziabad – 201015, UP, India
ENERGIZING YOUR FUTURE POWER
We are glad to introduce ourselves as one of the leading manufacturer of
measuring and Protection in High Voltage and Extra High Voltage Systems
(Current Transformers and Potential Transformer) upto the System voltage of
33KV.
OVERVIEW
ANJNI TRANSFORMER & SWITCHGEARS, founded by Er. DINESH KUMAR
GOEL and Mr. SHOKAUT Ali, supported by a dedicated team of Engineers,
Technicians and Business people, committed to a Technology, best quality
products, has been in the field of Power Sector for more than 30 Years and
now established a Setup of Manufacturing state of High Voltage Power
Products, since 2005, and as we have already told above that both Mr.
Sharafat Ali, Technical Professional having more than 24 years of experience
in Power Sector especially Instrument Transformers Category. We have very
good contacts with almost all EPC Contractors/Electrical Contractors/ PSU
Units/ Boards/Nigams. Every time, We will developed a strong clientele
by supplying high quality product to varying specifications.
APPROVALS
We are Approved in Himachal, UPCL, UJVNL PTCUL, DVVNL, HPSEB.
KINDLY NOTE THAT OUR 11KV/22KV/33KV CTs/PTs/COMBINED
CTPT UNIT HAVE BEEN APPROVED WITH HPSEB.
Apart from Manufacturing CTs/PTs upto 33KV, we are also engaged in HEAVY
FABRICATION ON TURNKEY BASIS AS PER DRAWING(S) viz. STEEL
STRUCTURES.
FACTORY SET UP
ANJNI TRANSFORMER & SWITCHGEARS has factory setup with well-
equipped laboratories, testing department with all facilities for production
check for raw material, semi-finished product and final product.
Carpet area of the factory is 4500 Sq. feet and office area 500 sq. feet at G-99
& Fabrication of CTs/PTs Tanks covered area is 5000Sq. feet and
400Sq. feet tools & Scrap area.
ENERGIZING YOUR FUTURE POWER
MOTTO
Quality, customer satisfaction and regular improvement for better to best Quality
Products.
COMMITTED TO
• Design, develop, manufacture and service quality products as per
customer requirement.
• Carry out production as per the standard procedures.
• Improvement in product and service
As mentioned earlier, ANJNI TRANSFORMER & SWITCHGEARS is one among
those organizations in India that provides total power solution forms under a single
roof: The products and the corresponding range follows:
MANUFACTURING OF INTRUMENT TRANSFORMERS UPTO 33KV
Sr.
No
DESCRIPTION OF ITEMS MANUFACURED RANGE
1 RESIN CAST CT RING TYPE & T A P E W O U N D C T 440V/660V
2 3 PHASE PTs Up to 33kV
3 Single Phase Resin Cast GUN Type PTs 33KV
4 RESIN CAST CT Up to 33kV
5 RESIN CAST PT Up to 33kV
6 COMBINED CTPT METERING SET (33kV, 22kV, 11kV) Up to 33 kV
7 OUTDOOR, SINGLE PHASE CURRENT
TRANSFORMERS
Up to 33 Kv
8. OUTDOOR, SINGLE PHASE POTENTIAL
TRANSFORMERS
Up to 33 kV
9. Pilfer Resistance CTPT Metering Cubicle Upto 33KV
10. Cycloaliphatic Outdoor Epoxy Cast CTs & PTs Uptp 33KV
11. Bus Duct CTs 440V
12. Resin Cast Residual Voltage Transformers Upto 33KV
TYPE TEST
Our all Products are type tested from Govt. Laboratory ERDA, Vadodara.
ENERGIZING YOUR FUTURE POWER
MANUFACTURING OF SMC (Sheet Moulding Compound) Distribution Boxes
Sr.
No
DESCRIPTION OF ITEMS MANUFACURED
1 Single Phase SMC LTDB for AB Cable
2 1-Phase / 3-Phase SMC Meter Boxes for Energy Meters
3 Three Phase SMC LTDB for AB Cable
4 3-Phase SMC type Tri-Vector Meter Box
5 1-Phase SMC LTDB for 10KVA Transformer with MCCB
6 1-Phase SMC LTDB for 16KVA Transformer with MCCB
7 1-Phase SMC LTDB for 25KVA Transformer with MCCB
8. 1-Phase SMC LTDB for 63KVA Transformer with MCCB
9. 1-Phase SMC LTDB for 100KVA Transformer with MCCB
10. 1-Phase SMC LTDB for 200KVA Transformer with MCCB
11. 1-Phase SMC LTDB for 400KVA Transformer with MCCB
12. SMC type LTDB with 2 sets of 100A Fuses connected on 300A
Aluminium Bus-bar (FP Kit-Kat)
13. SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 100/5A for metering of 25KVA & 63KVA
Transformer
14. SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 200/5A for metering of 100KVA Transformer
15 SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 400/5A for metering of 200KVA Transformer
16 SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets
of CTs Ratio 600/5A for metering of 400KVA Transformer
ENERGIZING YOUR FUTURE POWER
DISTRIBUTION BOARDS
Apart from Manufacturing Instrument Transformers upto 33KV, Anjni Transformer &
Switchgears is engaged in inhouse Fabrication CT/PT Tanks upto 220KV &
Manufacturing of SMC (Sheet Moulded Compound) DISTRIBUTION BOARDS
1. Complete inhouse Fabrication of CTs & PTs tanks upto 220KV as per drawings.
2. LT DISTRIBUTION BOXES, 25KVA to 315KVA with Kitkat fuse as per drawing in
SMC type
3. LTCT Metering Cubicle of any Ratio, class & burden
4. Transformer Protection Boxes 10KVA/16KVA/25KVA/63KVA/100KVA/200KVA/
400KVA with MCCB as per drawing
5. Single Phase SMC Distribution Box for LT Pole 1.1 kV with clamp, Nuts & Bolts
ENERGIZING YOUR FUTURE POWER
6. Three Phase SMC Distribution Box with clamp, Nuts & Bolts
7. LT Distribution Box with MCCB for protection of 16 KVA T/F and Bus Bar for 10No.
outgoing consumer connections and suitable to house Energy meter (without
Energy meter)
LIST OF PLANT AND MACHINERY
Sr. No.
Name Of
Machine/Equipment
Brief Specification Qty
1 Coil Drying Oven
Drying Oven Temp.150 deg at
atmospheric pressure
1 No
2 Drilling Machine
Vertical drilling Machine with3/4”
Capacity
2 Nos
3 Storage Bins & Racks
Industrial storage plastic bins &
M.S.Racks to stores material
3 Nos
4 H.V.Coil winding machine
(Motorized)
Axial winding machine with maximum
250 mm & axial Width 300mm Suitable 2 Nos
5
L .V. Coil winding
machine (Motorized)
Axial winding machine with maximum
250 mm & axial Width 300mm Suitable
Upto 22 swg Copper wire
2 Nos
6
H.V.Coil winding machine
(Hand winding)
Axial winding machine with maximum
100mm & axial Width 120mm Suitable
Upto 42 swg Copper wire
2 Nos
7
Bench voice 12”jaw opening bench voice 2 Nos
8 Hand drill machine 10 mm bore capacity 2 Nos
9 Welding transformer
2 phase, capacity of 250 mm weld
current
2 Nos
10 Tooling Kit
Various tools for general purpose allen
keys, spanner sets 4 Sets
11
Brazing unit 150 Amp brazing Current 1 No
12
Air compressor For painting and finishing of work
1 No
13 Bending Machine
Suitable For Fabrication Bending Of
Sheet Metal Of Thickness 5 Mm
2 Nos
14 Shearing Machine
Suitable For Fabrication Cutting Of
Sheet Metal Of Thickness 5 Mm
2 Nos
15 Grinding Machine For De Baring Of Metal Fabrication 3 Nos
16 Welding Machine Welding Of Ms Metal Purpose 4 Nos
17 Oven Heating Purpose 2 Nos
18
Furnace Annealing of Core
1 No
LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF
RAW MATERIALS)
Sr. No.
Name Of
Machine/Equipment
Brief Specification
Calibration
status
Qty
1
Combined Digital CTPT
Test System for
measurement of ratio and
phase angle error
CTPT Digital Analyzer
Precision for CT Ratio upto 3200A of
accuracy upto 0.005
PT for 0 to 207.5VA with printer
facility
calibrated 1 Set
2
Combined CT Test System
for measurement of ratio
and phase angle error
Test system consisting Of test set
CT TEST BRIDGE FOR 5A& 1A
calibrated 1 Set
3
Burden Box
Burden Box Of 40 VA Of 5 A
Burden Box 40 VA Of 1 A calibrated 1 Set
4
Standard CT
0-5-10-15-20-25-30-40-50-60-75-
80-100-125-150-200/5 AMP calibrated 1 Set
0-5-10-15-20-25-30-40-50-60-75-
80-100-125-150-200/1 AMP
1 Set
5
Combined PT Test System
for measurement of ratio
and phase angle error
Test system consisting Of test set
PT Test Bridge
calibrated 1 Set
6
6
Burden Box For PT
Burden Box Of 105 VA Capacity
Of Output 110 Volts
calibrated
1 Set
Burden Box Of 105 VA Capacity
Of Output 63.5 Volts
calibrated
1 Set
7
Standard PT’s
Standard 11kV PT 1ø /2ø
Ratio: 11kV / 110V and 11Kv / rt3
/110V /rt3
1 Set
Standard 22Kv PT 1ø /2ø
Ratio: 22Kv / 110V and 22Kv / rt3
/110V /rt3
calibrated
1 Set
Standard 33Kv PT 1ø /2ø
Ratio: 33Kv / 110V and 33Kv / rt3
/110V /rt3
calibrated
1 Set
8
High frequency generator
set with control panel
Coupled motors with panel having
frequency
meter to get double voltage and
frequency for testing of PT’s
calibrated
1 Set
9 High voltage AC Test
System
Test system consisting of HV test
transformer 80kv, 4kVA
continuous, control desk panel
with Ammeter, kV meter, and
tripping circuit of 20mA
calibrated
1 Set
10
5 kV High voltage AC Test
System.
Test system consisting of 0-5 kV
High voltage Transformer,
Manual voltage regulator
calibrated
1 Set
11 Set Of Voltmeter
Portable type precision type
voltmeter
RANGE: COM –75-150-300 VOLTS
RANGE; COM-150-300-600
VOLTS
calibrated
4 Nos
12 Set Of Ammeter
Portable type precision type
voltmeter
RANGE: COM-5A-10A-25A-50A-
100A
RANGE: COM-500ma- 1A –5A
calibrated
4 Nos
LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF
RAW MATERIALS)
Sr. No.
Name Of
Machine/Equipment
Brief Specification
Calibration
status
Qty
12 Current Source
220V/0-1500 amps with suitable
taps and capacity of 3.5 kVA
calibrated
1 Set
13
Resistance Measuring
Bridge
4 Terminal Milli ohmmeter from
199.9 micro ohm to 19.9 kilo
Ohms
calibrated
1 No
14 Polarity Meter General Purpose Analog Meter
calibrated
3 Nos
15 Voltage Regulator
0-415n Volts output
28A. Auto Transformer
input 415 volts 3 PHASE
calibrated
2 Nos
16 Continuity Meter
General Purpose Analog
Multimeter
calibrated
1 No
17
Digital General purpose
Multimeter
General purpose Multimeter with
facilities of AC DC voltage
measurement, Ammeters
Resistance Measurement
calibrated
2 Nos
18 Megger Meter
5 kV MEGGER to measure
insulation resistance value
calibrated
2 Nos
19
Clip – On Meter
MAKE MECO
0– 1000 Amp, 750 Volts
calibrated
1 No
QUALITY SYSTEMS AND PROCEDURES
1. BROUGHT OUT ITEMS (RAW MATERIALS)
1.1. COPPER
- Maintaining Test Report for purchase from standard manufacturers
- Testing class of insulation of enamel covering by performing temperature test
- Electrical Breakdown Value (BDV) Test of enamel covering
- Maintaining records of each spool used for individual job
1.2. PAPER
- Maintaining Test Report for purchase from standard manufacturers
- Testing class of insulation by carrying temperature test
- Electrical Breakdown Value (BDV) Test
1.3. OIL
- Maintaining Test Report for purchase from standard manufacturers
- Electrical Breakdown Value (BDV) Test
1.4. CORE
- Maintaining Test Report for purchase from standard manufacturers
- Verifying the grade of material
- Checking of Knee Point Voltage (SATURATION OF CORE)
2. IN HOUSE TEST (SEMI FINISHED & FINISHED GOODS)
2.1. COIL
- Resistance Of Coil
- Maintaining records of coil used for each job
- Examining dimensional records of coil
- Maintaining records of worker, responsible for the winding
2.2. SEMI FINISHED & FINISHED GOODS
- Maintaining test report of SEMI FINISHED & FINISHED GOODS
- Analyzing the reports of failures in intermediate stages and taking corrective measures accordingly
- Analyzing the reports of failures in final stage and taking corrective measures accordingly
- Examining the final reports before dispatch
3. EQUIPMENTS
3.1. TEST EQUIPMENT & MACHINERIES
- Periodically calibrating and reconditioning of test equipment and machineries from standard
government and private labs, required for testing in the production process.
3.2. PERIODICAL MAINTENANCE OF PLANT AND MACHINERIES
4. TESTS
4.1. TYPE TEST
- Timely performing the type test of the manufactured product in N.A.B.L accribated labs like E.R.D.A
(Electronic Research and Development Association) and C.P.R.I (Central Power and Research
Institute).
PRODUCT PROFILE
CURRENT TRANSFORMER
Our all the Epoxy Resin Cast Instrument Transformers & Epoxy Cast Components are
Manufactured through Automatic Machine.
APPLICATION –Direct measurement of current in high voltage & high current system is not possible because of
difficulty in electrical isolation of measuring instruments. Because of its high value,it is also not possible to use current flowing
directly to the system, so that current transformer are used to step down the high system current into low system measuring
current with their proportionate ratio. due to this it is possible to measure high system current by using standard measuring
instruments & relays, also its isolate meters,relays from high voltage systems.
VARIOUS TYPES OF CURRENT TRANSFORMERS
Ring Type Current Transformers : A Current Transformer which has an window
in the center to accommodate a primary conductor (busbar or cable) through it.
Bar -PrimaryCurrent Transformers : A Current Transformer in which the
primary winding consists of bar of suitable size and it is an integral part of the CT.
Wound Type Current Transformers : A Current Transformer having a primary
winding of more than one full turn wound on the core.
Interposing Current Transformers : These Current Transformers are used in
conjunction with main CTs to alter the ratio of main CT or to provide isolation to
meters or relays from main CTs secondary circuit. Primary current of these CTs
are generally lower than 1 0 amp. Due to which they are always wound primary
type.
Summation Current Transformers :W hen current flowing, in more than one
feeder is required to be metered summation current transformer are used. These
Current Transformers are provided with more than one primary winding and one
common secondary.
Bushing Type or Busduct Current Transformers : These Current
Transformers are Ring type construction & can be mounted on Busduct or
Bushing turrert of power transformer.
Core Balance Current Transformers : These are ring type Current
Transformers & suitable for the measurement of the sum of three phase currents
in a 3-ph cable. Under normal operating conditions this sum is zero. In the event
of an earth-fault the sum of the current is equal to the zero sequence current.
.
RESIN CAST CURRENT TRANSFORMER
Technical Specification As Per IS : 2705
RANGE – 11, 22 & 33 KV
ACCURACY CLASS – 0.2 & 0.5
SPECIAL ACCURACY CLASS – 0.2S & 0.5S
IS : 2705
General Particulars 11KV 22KV 33 KV
Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequencydry/ wet withstand
voltage on primarywinding for one
minute
28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
Lightning Impulse withstand voltage
(1.2 x 50 µ s )
75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
PD measuring Voltage / Permissible
Voltage
7.6/50 15.2/50 23.0/50
Specific Particulars
Rated Transformation Ratio As per customer requirement (in Amp.)
Rated PrimaryCurrent Upto 2000 Amp.
Rated SecondaryCurrent 1 Amp. 5 Amp. 0.577 Amp.
Short Time Thermal Current (Ith)
As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Short Time Dynamic Current 2.5 X Ith KA (Peak)
Number of Cores Upto 3 cores
Output Burden Upto 60VA, 0.8 pf Lagging
AccuracyClass
For Metering :
0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00.
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point Voltage,
Exciting Current & Resistance
As per customer requirement / Design Constraints
Type of construction As Per Panel Conditions(Customer Requirement)
OIL COOLED CURRENT TRANSFORMER
Technical Specification As Per IS : 2705
General Particulars 11KV 22KV 33 KV 66 KV
Highest System
Voltage( H.S.V.)
12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) 72 KV (r.m.s.)
Power frequency dr y/
wet withstand voltage
on primarywinding
for one minute
28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) 150 KV ( r.m.s.)
Lightning Impulse
withstand voltage (1.2
x 50 µ s )
75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) 350 KV ( r.m.s.)
Specific Particulars
Rated Transformation
Ratio
As per customer requirement (in Amp.)
Rated PrimaryCurrent Upto 2000 Amp.
Rated Secondary
Current
1 Amp. 5 Amp. 0.577 Amp.
Short Time Thermal
Current (Ith)
As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal
to the system fault level whichever is lower. KA ( r.m.s. )
Short Time Dynamic
Current
2.5 X Ith KA (Peak)
Number of Cores Upto 5 cores
Output Burden Upto 60VA, 0.8 pf Lagging
AccuracyClass
For Metering :
0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00.
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point
Voltage, Exciting
Current & Resistance
As per customer requirement / Design Constraints
Type of construction Dead / Bottom Tank or Live / Top Tank
POTENTIAL TRANSFORMER
APPLICATION – Direct measurement of voltage in high voltage & high current system is not possible because of
difficulty in electrical isolation of measuring instruments. Because of its high value, it is also not possible to use voltage
directly to the system, so that Potential transformer are used to step down the high system voltage into low system
measuring voltage with their proportionate ratio. due to this it is possible to measure high system voltage by using
standard measuring instruments & relays, also its isolate meters, relays from high voltage systems and also to sense
abnormalities in voltage & give signal to protective relay to isolate the defective system.
RESIN CAST POTENTIAL TRANSFORMER
RANGE – 11, 22 & 33 KV
ACCURACY CLASS – 0.2 & 0.5
SPECIAL ACCURACY CLASS – 0.2S & 0.5S
IS : 3156
Technical Specification As Per IS : 3156
General Particulars 11KV 22KV 33 KV
Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequencydry/ wet withstand
voltage on primarywinding for one
minute
28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
Lightning Impulse withstand Voltage (
1.2 x 50 µ s )
75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
PD measuring Voltage / Permissible
Voltage
7.6/50 15.2/50 23.0/50
Specific Particulars
Number of Phases 3 or 1 unearthed or earthed
Rated Transformation Voltage Ratio As per customer requirement
Number of SecondaryWindings Upto 3
Output Burden Upto 100VA
AccuracyClass For Metering : 0.2, 0.5 & 1.0
For Protection: 3P, 6P
Voltage Factor 1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for
8 hours
0IL COOLED POTENTIAL TRANSFORMER
OIL COOLED POTENTIAL TRANSFORMERS
Technical Specification As Per IS : 3156
General Particulars 11KV 22KV 33 KV 66 KV
Highest System
Voltage( H.S.V.)
12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) 72 KV (r.m.s.)
Power frequency
dry/ wet withstand
voltage on primary
winding for one
minute
28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) 150 KV ( r.m.s.)
Lightning Impulse
withstand Voltage (
1.2 x 50 µ s )
75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) 350 KV ( r.m.s.)
Specific Particulars
Number of Phases 3 or 1 unearthed or earthed
Rated
Transformation
Voltage Ratio
As per customer requirement
Number of
SecondaryWindings
Upto 3
Output Burden Upto 500VA
AccuracyClass For Metering : 0.2, 0.5,1.0 & 3.0
For Protection: 3P, 6P
Voltage Factor 1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for 8 hours
COMBINED CTPT SET
APPLICATION- Combined CTPT Metering Units that are available up to 33 kV class are manufactured specifically to
meet the needs of Electricity Supply and captive generating units. The C.T.-P.T. metering sets of this type as the name
suggests are used for measurement of power on high voltage side. The C.T.-P.T. sets are installed before the main
transformer and the main line goes through C.T.-P.T. set to the main transformer. Metering equipment is connected to the
secondary side of the C.T.-P.T. set. As the accuracy of the C.T.-P.T. set is high & as it is connected before the transformer,
measurement of power is much more accurate compared to the metering done on L.T. side, the transformer losses are
also included in the measurement.
OIL COOLED CTPT SET RESIN CAST 3 Ø PT
Technical Specification For Oil Cooled CTPT Set As Per IS:2705 & IS:3156
General Particulars 11KV 22KV 33 KV
Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequencydry/ wet withstand
voltage on primarywinding for one
minute
28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
Lightning Impulse withstand Voltage (
1.2 x 50 µ s )
75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
System Particulars
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidlyearthed.
3 Nos. CTs & 1 No. 3 - Phase PT
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidlyearthed.
2 Nos. CTs & 1 No. 3 - Phase PT
Specific Particulars
Short Time Thermal Current (Ith) As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Output 10 VA to 100 VA for PT and 5 VA to 30 VA for CT
AccuracyClass 0.2S, 0.2, 0.5S, 0.5, 1.0 for CT. and 0.2, 0.5 & 1.0 for PT
SecondaryCurrent (CT) 1 Amp or 5 Amp
SecondaryVoltage (VT) 110 Ph-Ph or 110/v3 V, Ph-Neutral
PrimaryCurrent (CT) As per customer requirement.
PrimaryVoltage (VT) 11KV, 22KV, 33KV for 3-Phase PT
11/v3, 22/v3, 33/v3 for 1-Phase PT
Technical Specification For resin cast CTPT Set As Per IS:2705 & IS:3156
General Particulars 11KV 22KV 33 KV
Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.)
Power frequencydry/ wet withstand
voltage on primarywinding for one
minute
28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.)
Lightning Impulse withstand Voltage
( 1.2 x 50 µ s )
75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.)
PD measuring Voltage / Permissible
Voltage
7.6/50 15.2/50 23.0/50
System Particulars
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidlyearthed.
3 Nos. CTs & 1 No. 3 - Phase PT
3 Nos. CTs & 3 Nos. 1 - Phase PT
3 Phase 4 Wire with Isolated / Floating
neutral as well as solidlyearthed.
2 Nos. CTs & 1 No. 3 - Phase PT
2 Nos. CTs & 3 Nos. 1 - Phase PT
Specific Particulars
Short Time Thermal Current (Ith) As per customer requirement.
In general CT is to be specified with STF of 100 for 1 Sec.
or STC (lth) equal to the system fault level whichever is
lower. KA ( r.m.s. )
Output 10 VA to 100 VA for PT
5 VA to 30 VA for CT
AccuracyClass 0.2S, 0.2, 0.5S, 0.5, 1.0 for CT.
0.2, 0.5 & 1.0 for PT
SecondaryCurrent (CT) 1 Amp or 5 Amp
SecondaryVoltage (VT) 110 Ph-Ph or 110/v3 V, Ph-Neutral
PrimaryCurrent (CT) As per customer requirement.
PrimaryVoltage (VT) 11KV, 22KV, 33KV for 3-Phase PT
11/v3, 22/v3, 33/v3 for 1-Phase PT
SL. Particulars Unit Description
1 Type of Box Sheet Metal or SMC
2 Type of CT Epoxy Resin Cast Bar Primary L.T.C.T
3 Operating System Voltage V 230 , 440
4 Power Frequency Dry
withstand Voltage
KVp(rms)
3 to 6
5 Transformation ratio Amp 50 to 1200 or as per requirement
6 Rated Secondary Current Amp 5.0
7 Fault Level of CT KA upto 6 KA for 1 or 3 sec
8
No of CT
no 4 Nos for 3Phase 4Wire System
3 Nos for 3Phase 3Wire System
9 Output Burden VA Upto 30 at 0.8 pF lag.
10 Accuracy class -
Low Tension Pilfer Resistant Metering Cubicle
Types:- L.T to 33 KV Voltages Class
1/2/3 one to Five core available
Various outline Size as per Customer requirement
Bar and Wound primary Type
Features:- Compact in design, Low cost and maintenance free.
Used mainly for outdoor LT metering on poles.
Separate Meter compartment and CT compartment.
CT's are epoxy molded to avoid any pilferage.
CT's are provided with various inner diameter according to requirement of cable size.
Complete dust & vermin proof confirming to IP55 with locking and sealing arrangement..
No secondary circuit wires are accessible outside which avoids chances of energy theft.
Stable accuracy over life time.
Provision of installing modem inside the cubicle provided
Non hygroscopic CT's.
Application:- Precision check metering, control indication...
Largely used for Metering of LT consumers .
Specification
SL. Particulars 11 KV 15 KV 22 KV 33 KV
1 Highest System Voltage kV 12 17 24 36
2 Power Freq dry/wet withstand voltage KVp rms 28 36 50 70
3 Lightning Impulse Voltage 1.2/50 µs KVp 75 110 125 170
4 Partial Discharge Measuring Voltage/ Limit. KV/pC 7.6KV/50pC 10.8KV/50pC 15.2KV / 50pC 23KV / 50pC
5 Transformation ratio Amp As per customer requirement.
6 Rated Primary Current Amp Upto 1000 Amp
7 Rated Secondary Current Amp 1.0, 5.0
8 Rated Secondary Voltage Volts 110/√3 for Ph-Neutral, 110 for Ph-Ph
9 Rated Secondary Current Amp 1.0, 5.0
10 Short Time Current Rating KA(rms) Upto 25KA for 1 or 3 sec
11
Out put Burden
VA Upto 30 at 0.8 pf lag for CT
Upto 100 at 0.8 pf lag for PT
12 Accuracy class -
For CT - 0.2, 0.2s, 0.5, 0.5s, 1.0, 3.0 & 5.0
For VT - 0.2, 0.5, 1.0
EPOXY RESIN CAST PILFER RESISTANT METERING CUBICLE/PANEL
Types:- 11KV to 33KV Voltage Class
3 no C.T's & 3 No Single Phase VT'S
3 no C.T's & 1 No Three Phase VT'S
Features:- Compact in design, Low cost and maintenance free.
Separate Meter compartment and CT-PT compartment.
Available in 3Phase 3W ire and 3Phase 4Wire systems.
CT's & PT's are epoxy molded to avoid any pilferage.
Complete dust & vermin proof confirming to IP55 with locking and sealing
arrangement.
No secondary circuit wires are accessible outside which avoids chances of energy
theft.
Stable accuracy over life time.
Designed mainly for Indoor applications
Non hygroscopic CT's & PT's.
Application:- Precision Revenue metering, control indication.
Used for Double Metering of Transformers.
Used on Feeder Metering for energy accounting.
Specification
Office address :
F-285, UPSIDC, Khichra Industrial Area, Meerut-
Guwahati Road,
Ghaziabad – 201001, UP, India
Phone No. : +91-9210927863 / +91-9313115696/ +91-9868667484
E-mail ID : mew.ctpt@gmail.com /
luckyindiapowersolutions@gmail.com / info@luckyindiapowersolution.com
Contact Details :
Mr. Shokaut Ali / Mr. Sharafat Ali
Phone No. : +91-9313115696 / + 91-9868667484
E-mail ID : mews.ctpt@gmail.com / luckyindiapowersolutions@gmail.com /
anjni10@rediffmail.com
Mr. DINESHGOEL
Phone No. : +91-9818884692 / +91-9012184692
E-mail ID : dgoel90@gmail.com / anjni10@rediffmail.com
http://www.indiamart.com/jayaelectricals
ISO: 9001: 2008
-
G-99 & G-3, UPSIDC Industrial Area, Phase-I,
M. G. Road, Ghaziabad – 201015, Uttar Pradesh, India
Tel.: +91-7088081626 / +91-9313115696 / +91-9818884692
Email: anjni10@rediffmail.com / luckyindiapowersolutions@gmail.com / dgoel90@gmail.com
http://www.indiamart.com/jayaelectricals

More Related Content

What's hot

1.MCB -Meba
1.MCB -Meba1.MCB -Meba
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
PT. Siwali Swantika
 
Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...
Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...
Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...
PT. Siwali Swantika
 
Turbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from HofferTurbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from Hoffer
Flow-Tech, Inc.
 
Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...
PT. Siwali Swantika
 
Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...
Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...
Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...
htrindia
 
Datasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration Option
Datasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration OptionDatasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration Option
Datasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration Option
PT. Siwali Swantika
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process Control
Classic Controls, Inc.
 
Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.
Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.
Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.
Acmas Technologies Pvt. Ltd.
 
Heb new
Heb newHeb new
Heb new
htrindia
 
HVE
HVEHVE
Professional electrical testing services in delhi
Professional electrical testing services in delhiProfessional electrical testing services in delhi
Professional electrical testing services in delhi
Spectro Group of Companies
 
คู่มือการใช้งาน Danfoss รุ่น KPi
คู่มือการใช้งาน Danfoss รุ่น KPiคู่มือการใช้งาน Danfoss รุ่น KPi
คู่มือการใช้งาน Danfoss รุ่น KPi
DNTMb Inc.
 
Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618
PT. Siwali Swantika
 
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
PT. Siwali Swantika
 
Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618
PT. Siwali Swantika
 
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMagnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Miller Energy, Inc.
 
A cast alloy power point presentation
A cast alloy power point presentationA cast alloy power point presentation
A cast alloy power point presentation
Bob P
 
Glass level gauges 2015 rev 0
Glass level gauges   2015 rev 0Glass level gauges   2015 rev 0
Glass level gauges 2015 rev 0
cherylteooo
 

What's hot (19)

1.MCB -Meba
1.MCB -Meba1.MCB -Meba
1.MCB -Meba
 
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 96000 Extended Specification. Hubungi PT. Siwali Swantika 021...
 
Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...
Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...
Datasheet Fluke 52120A Extended. Specification. Hubungi PT. Siwali Swantika 0...
 
Turbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from HofferTurbine flow meters for gas service from Hoffer
Turbine flow meters for gas service from Hoffer
 
Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...
Datasheet Fluke 5790B Extended Specification. Hubungi PT. Siwali Swantika 021...
 
Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...
Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...
Htr india-products-current-sense-resistors-ceramic-encased-resistor-hcal-engl...
 
Datasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration Option
Datasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration OptionDatasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration Option
Datasheet Fluke 5080A Multi-Product Calibrator MegOhm Meter Calibration Option
 
Current To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process ControlCurrent To Pneumatic Converter for Process Control
Current To Pneumatic Converter for Process Control
 
Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.
Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.
Multi Function Process Calibrator by ACMAS Technologies Pvt Ltd.
 
Heb new
Heb newHeb new
Heb new
 
HVE
HVEHVE
HVE
 
Professional electrical testing services in delhi
Professional electrical testing services in delhiProfessional electrical testing services in delhi
Professional electrical testing services in delhi
 
คู่มือการใช้งาน Danfoss รุ่น KPi
คู่มือการใช้งาน Danfoss รุ่น KPiคู่มือการใช้งาน Danfoss รุ่น KPi
คู่มือการใช้งาน Danfoss รุ่น KPi
 
Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 9190A. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 52102A. Hubungi PT. Siwali Swantika 021-45850618
 
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMagnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
 
A cast alloy power point presentation
A cast alloy power point presentationA cast alloy power point presentation
A cast alloy power point presentation
 
Glass level gauges 2015 rev 0
Glass level gauges   2015 rev 0Glass level gauges   2015 rev 0
Glass level gauges 2015 rev 0
 

Viewers also liked

The technion library system 2015 vision mission and challenges july2015
The technion library system 2015  vision mission and challenges july2015The technion library system 2015  vision mission and challenges july2015
The technion library system 2015 vision mission and challenges july2015
Dalia Dolev
 
Kena roots products-superiority-presentation
Kena roots products-superiority-presentationKena roots products-superiority-presentation
Kena roots products-superiority-presentation
Dr. Hani Malkawi
 
De technologie staat verder dan u denkt
De technologie staat verder dan u denktDe technologie staat verder dan u denkt
De technologie staat verder dan u denkt
dbintein
 
Claims
ClaimsClaims
Claimsaec111
 
Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27
Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27
Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27
John JenJen
 
Email Advertising
Email AdvertisingEmail Advertising
Email Advertising
Kalob Taulien
 
Proyecto investigación
Proyecto investigación Proyecto investigación
Proyecto investigación
José María García de Prado
 
Leonor Pacheco Palomares
Leonor Pacheco PalomaresLeonor Pacheco Palomares
Leonor Pacheco Palomares
Leonor Pacheco
 
Stirling Henry Us Aust Corp Immi May 2010
Stirling Henry Us Aust Corp Immi May 2010Stirling Henry Us Aust Corp Immi May 2010
Stirling Henry Us Aust Corp Immi May 2010tim_denney
 
Seven barriers to payments
Seven barriers to paymentsSeven barriers to payments
Seven barriers to paymentsBillingViews
 
Maximising the return of your website for data driven marketing congress
Maximising the return of your website for data driven marketing congressMaximising the return of your website for data driven marketing congress
Maximising the return of your website for data driven marketing congressdbintein
 
Presentación Corporativa Gyga
Presentación Corporativa Gyga Presentación Corporativa Gyga
The Technion Library as a physical environment - July 2012
The Technion Library as a physical environment - July 2012The Technion Library as a physical environment - July 2012
The Technion Library as a physical environment - July 2012
Dalia Dolev
 
Info2011 DaliaDolev-Technion
Info2011 DaliaDolev-TechnionInfo2011 DaliaDolev-Technion
Info2011 DaliaDolev-TechnionDalia Dolev
 
WebGL For Game Development 2012
WebGL For Game Development 2012WebGL For Game Development 2012
WebGL For Game Development 2012
Tony Parisi
 
Kompanihuset
KompanihusetKompanihuset
Kompanihusetfalster5
 
Stortorget.
Stortorget.Stortorget.
Stortorget.falster5
 
Konsep Tanzil: Arkoun dan Zarqani
Konsep Tanzil: Arkoun dan ZarqaniKonsep Tanzil: Arkoun dan Zarqani
Konsep Tanzil: Arkoun dan ZarqaniAnwar Ma'rufi
 

Viewers also liked (20)

The technion library system 2015 vision mission and challenges july2015
The technion library system 2015  vision mission and challenges july2015The technion library system 2015  vision mission and challenges july2015
The technion library system 2015 vision mission and challenges july2015
 
Kena roots products-superiority-presentation
Kena roots products-superiority-presentationKena roots products-superiority-presentation
Kena roots products-superiority-presentation
 
De technologie staat verder dan u denkt
De technologie staat verder dan u denktDe technologie staat verder dan u denkt
De technologie staat verder dan u denkt
 
Claims
ClaimsClaims
Claims
 
Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27
Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27
Pakej Rujukan Peperiksaan Online Penolong Penguasa Kastam Gred W27
 
Email Advertising
Email AdvertisingEmail Advertising
Email Advertising
 
Proyecto investigación
Proyecto investigación Proyecto investigación
Proyecto investigación
 
Leonor Pacheco Palomares
Leonor Pacheco PalomaresLeonor Pacheco Palomares
Leonor Pacheco Palomares
 
Stirling Henry Us Aust Corp Immi May 2010
Stirling Henry Us Aust Corp Immi May 2010Stirling Henry Us Aust Corp Immi May 2010
Stirling Henry Us Aust Corp Immi May 2010
 
Seven barriers to payments
Seven barriers to paymentsSeven barriers to payments
Seven barriers to payments
 
Maximising the return of your website for data driven marketing congress
Maximising the return of your website for data driven marketing congressMaximising the return of your website for data driven marketing congress
Maximising the return of your website for data driven marketing congress
 
Presentación Corporativa Gyga
Presentación Corporativa Gyga Presentación Corporativa Gyga
Presentación Corporativa Gyga
 
The Technion Library as a physical environment - July 2012
The Technion Library as a physical environment - July 2012The Technion Library as a physical environment - July 2012
The Technion Library as a physical environment - July 2012
 
Info2011 DaliaDolev-Technion
Info2011 DaliaDolev-TechnionInfo2011 DaliaDolev-Technion
Info2011 DaliaDolev-Technion
 
WebGL For Game Development 2012
WebGL For Game Development 2012WebGL For Game Development 2012
WebGL For Game Development 2012
 
Kompanihuset
KompanihusetKompanihuset
Kompanihuset
 
Mark fx presentation
Mark fx presentationMark fx presentation
Mark fx presentation
 
Online reputatie-2012
Online reputatie-2012Online reputatie-2012
Online reputatie-2012
 
Stortorget.
Stortorget.Stortorget.
Stortorget.
 
Konsep Tanzil: Arkoun dan Zarqani
Konsep Tanzil: Arkoun dan ZarqaniKonsep Tanzil: Arkoun dan Zarqani
Konsep Tanzil: Arkoun dan Zarqani
 

Similar to Catalogue-Oil Cooled-Resin Cast CTs-PTs-ATS

Pragati pt cataloge
Pragati pt catalogePragati pt cataloge
Pragati pt cataloge
sambit mohapatra
 
Shyam cable catalogue
Shyam cable catalogueShyam cable catalogue
Shyam cable catalogueuibsamit87
 
Brochure of LTCT & HT
Brochure of LTCT & HTBrochure of LTCT & HT
Brochure of LTCT & HT
MAGNA TECH
 
Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)
Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)
Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)
ProSIM R & D Pvt. Ltd.
 
ABB Price List of Capacitors 008
ABB Price List of Capacitors 008ABB Price List of Capacitors 008
ABB Price List of Capacitors 008
R Sanghavi Mercantile Pvt Ltd
 
New Test Equipment
New Test EquipmentNew Test Equipment
transformer Manufactures and exporters in India
transformer Manufactures and exporters in Indiatransformer Manufactures and exporters in India
transformer Manufactures and exporters in India
seo27poogle
 
ELECHTRICAL COMMISSIONING TECHNICIAN 2201622
ELECHTRICAL   COMMISSIONING  TECHNICIAN   2201622ELECHTRICAL   COMMISSIONING  TECHNICIAN   2201622
ELECHTRICAL COMMISSIONING TECHNICIAN 2201622MOHAMMAD KHALID MUSTAFA
 
Standing type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unitStanding type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unit
Rockwill T&D Group Manufacturer,Contractor, OEM, ODM
 
Industrial Automation Company In India | Electrical Automation Company in Ind...
Industrial Automation Company In India | Electrical Automation Company in Ind...Industrial Automation Company In India | Electrical Automation Company in Ind...
Industrial Automation Company In India | Electrical Automation Company in Ind...
codewithharsi
 
JRC Erection, Testing and Commissioning Profile v2.pdf
JRC Erection, Testing and Commissioning Profile v2.pdfJRC Erection, Testing and Commissioning Profile v2.pdf
JRC Erection, Testing and Commissioning Profile v2.pdf
Ekram Bin Mamun
 
Ngg power tech presentation
Ngg power tech presentationNgg power tech presentation
Ngg power tech presentation
NGG Power Tech India Pvt. Ltd.
 
TESCO TEST Products_5-2-23.ppt
TESCO TEST Products_5-2-23.pptTESCO TEST Products_5-2-23.ppt
TESCO TEST Products_5-2-23.ppt
TESCO - The Eastern Specialty Company
 
Kyn28 metal clad switchgear
Kyn28 metal clad switchgearKyn28 metal clad switchgear
Kyn28 metal clad switchgear
JoeChueng
 
NGG Power Tech India Private Limited Presentation
NGG Power Tech India Private Limited Presentation NGG Power Tech India Private Limited Presentation
NGG Power Tech India Private Limited Presentation
nggpowertech
 
Transformers
TransformersTransformers
Transformers
michaeljmack
 
Fcs capacitor switch
Fcs capacitor switchFcs capacitor switch
Fcs capacitor switch
JoeChueng
 
Powering Every House, Powering Every Industry
Powering Every House, Powering Every IndustryPowering Every House, Powering Every Industry
Powering Every House, Powering Every Industry
Akil Siddiqui
 

Similar to Catalogue-Oil Cooled-Resin Cast CTs-PTs-ATS (20)

Pragati pt cataloge
Pragati pt catalogePragati pt cataloge
Pragati pt cataloge
 
Shyam cable catalogue
Shyam cable catalogueShyam cable catalogue
Shyam cable catalogue
 
Brochure of LTCT & HT
Brochure of LTCT & HTBrochure of LTCT & HT
Brochure of LTCT & HT
 
Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)
Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)
Challenges in Transformer Technology -by Mr. Krishnaiah (Kryfs)
 
electrician
electricianelectrician
electrician
 
ABB Price List of Capacitors 008
ABB Price List of Capacitors 008ABB Price List of Capacitors 008
ABB Price List of Capacitors 008
 
New Test Equipment
New Test EquipmentNew Test Equipment
New Test Equipment
 
transformer Manufactures and exporters in India
transformer Manufactures and exporters in Indiatransformer Manufactures and exporters in India
transformer Manufactures and exporters in India
 
ELECHTRICAL COMMISSIONING TECHNICIAN 2201622
ELECHTRICAL   COMMISSIONING  TECHNICIAN   2201622ELECHTRICAL   COMMISSIONING  TECHNICIAN   2201622
ELECHTRICAL COMMISSIONING TECHNICIAN 2201622
 
Standing type GIS RMU
Standing type GIS RMUStanding type GIS RMU
Standing type GIS RMU
 
Standing type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unitStanding type outdoor full sf6 gas insualted ring main unit
Standing type outdoor full sf6 gas insualted ring main unit
 
Industrial Automation Company In India | Electrical Automation Company in Ind...
Industrial Automation Company In India | Electrical Automation Company in Ind...Industrial Automation Company In India | Electrical Automation Company in Ind...
Industrial Automation Company In India | Electrical Automation Company in Ind...
 
JRC Erection, Testing and Commissioning Profile v2.pdf
JRC Erection, Testing and Commissioning Profile v2.pdfJRC Erection, Testing and Commissioning Profile v2.pdf
JRC Erection, Testing and Commissioning Profile v2.pdf
 
Ngg power tech presentation
Ngg power tech presentationNgg power tech presentation
Ngg power tech presentation
 
TESCO TEST Products_5-2-23.ppt
TESCO TEST Products_5-2-23.pptTESCO TEST Products_5-2-23.ppt
TESCO TEST Products_5-2-23.ppt
 
Kyn28 metal clad switchgear
Kyn28 metal clad switchgearKyn28 metal clad switchgear
Kyn28 metal clad switchgear
 
NGG Power Tech India Private Limited Presentation
NGG Power Tech India Private Limited Presentation NGG Power Tech India Private Limited Presentation
NGG Power Tech India Private Limited Presentation
 
Transformers
TransformersTransformers
Transformers
 
Fcs capacitor switch
Fcs capacitor switchFcs capacitor switch
Fcs capacitor switch
 
Powering Every House, Powering Every Industry
Powering Every House, Powering Every IndustryPowering Every House, Powering Every Industry
Powering Every House, Powering Every Industry
 

Catalogue-Oil Cooled-Resin Cast CTs-PTs-ATS

  • 1. An ISO 9001:2008 Certified Company Anjni Transformers & Switchgears G-99 & G-3, Phase-I, UPSIDC, Khichra Industrial Area, Masuri-Gulawati Road, Ghaziabad – 201015, UP, India
  • 2. ENERGIZING YOUR FUTURE POWER We are glad to introduce ourselves as one of the leading manufacturer of measuring and Protection in High Voltage and Extra High Voltage Systems (Current Transformers and Potential Transformer) upto the System voltage of 33KV. OVERVIEW ANJNI TRANSFORMER & SWITCHGEARS, founded by Er. DINESH KUMAR GOEL and Mr. SHOKAUT Ali, supported by a dedicated team of Engineers, Technicians and Business people, committed to a Technology, best quality products, has been in the field of Power Sector for more than 30 Years and now established a Setup of Manufacturing state of High Voltage Power Products, since 2005, and as we have already told above that both Mr. Sharafat Ali, Technical Professional having more than 24 years of experience in Power Sector especially Instrument Transformers Category. We have very good contacts with almost all EPC Contractors/Electrical Contractors/ PSU Units/ Boards/Nigams. Every time, We will developed a strong clientele by supplying high quality product to varying specifications. APPROVALS We are Approved in Himachal, UPCL, UJVNL PTCUL, DVVNL, HPSEB. KINDLY NOTE THAT OUR 11KV/22KV/33KV CTs/PTs/COMBINED CTPT UNIT HAVE BEEN APPROVED WITH HPSEB. Apart from Manufacturing CTs/PTs upto 33KV, we are also engaged in HEAVY FABRICATION ON TURNKEY BASIS AS PER DRAWING(S) viz. STEEL STRUCTURES. FACTORY SET UP ANJNI TRANSFORMER & SWITCHGEARS has factory setup with well- equipped laboratories, testing department with all facilities for production check for raw material, semi-finished product and final product. Carpet area of the factory is 4500 Sq. feet and office area 500 sq. feet at G-99 & Fabrication of CTs/PTs Tanks covered area is 5000Sq. feet and 400Sq. feet tools & Scrap area.
  • 3. ENERGIZING YOUR FUTURE POWER MOTTO Quality, customer satisfaction and regular improvement for better to best Quality Products. COMMITTED TO • Design, develop, manufacture and service quality products as per customer requirement. • Carry out production as per the standard procedures. • Improvement in product and service As mentioned earlier, ANJNI TRANSFORMER & SWITCHGEARS is one among those organizations in India that provides total power solution forms under a single roof: The products and the corresponding range follows: MANUFACTURING OF INTRUMENT TRANSFORMERS UPTO 33KV Sr. No DESCRIPTION OF ITEMS MANUFACURED RANGE 1 RESIN CAST CT RING TYPE & T A P E W O U N D C T 440V/660V 2 3 PHASE PTs Up to 33kV 3 Single Phase Resin Cast GUN Type PTs 33KV 4 RESIN CAST CT Up to 33kV 5 RESIN CAST PT Up to 33kV 6 COMBINED CTPT METERING SET (33kV, 22kV, 11kV) Up to 33 kV 7 OUTDOOR, SINGLE PHASE CURRENT TRANSFORMERS Up to 33 Kv 8. OUTDOOR, SINGLE PHASE POTENTIAL TRANSFORMERS Up to 33 kV 9. Pilfer Resistance CTPT Metering Cubicle Upto 33KV 10. Cycloaliphatic Outdoor Epoxy Cast CTs & PTs Uptp 33KV 11. Bus Duct CTs 440V 12. Resin Cast Residual Voltage Transformers Upto 33KV TYPE TEST Our all Products are type tested from Govt. Laboratory ERDA, Vadodara.
  • 4. ENERGIZING YOUR FUTURE POWER MANUFACTURING OF SMC (Sheet Moulding Compound) Distribution Boxes Sr. No DESCRIPTION OF ITEMS MANUFACURED 1 Single Phase SMC LTDB for AB Cable 2 1-Phase / 3-Phase SMC Meter Boxes for Energy Meters 3 Three Phase SMC LTDB for AB Cable 4 3-Phase SMC type Tri-Vector Meter Box 5 1-Phase SMC LTDB for 10KVA Transformer with MCCB 6 1-Phase SMC LTDB for 16KVA Transformer with MCCB 7 1-Phase SMC LTDB for 25KVA Transformer with MCCB 8. 1-Phase SMC LTDB for 63KVA Transformer with MCCB 9. 1-Phase SMC LTDB for 100KVA Transformer with MCCB 10. 1-Phase SMC LTDB for 200KVA Transformer with MCCB 11. 1-Phase SMC LTDB for 400KVA Transformer with MCCB 12. SMC type LTDB with 2 sets of 100A Fuses connected on 300A Aluminium Bus-bar (FP Kit-Kat) 13. SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets of CTs Ratio 100/5A for metering of 25KVA & 63KVA Transformer 14. SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets of CTs Ratio 200/5A for metering of 100KVA Transformer 15 SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets of CTs Ratio 400/5A for metering of 200KVA Transformer 16 SMC type 3-Phase 4-Wire LTCT Metering Cubicle alongwith 4sets of CTs Ratio 600/5A for metering of 400KVA Transformer
  • 5. ENERGIZING YOUR FUTURE POWER DISTRIBUTION BOARDS Apart from Manufacturing Instrument Transformers upto 33KV, Anjni Transformer & Switchgears is engaged in inhouse Fabrication CT/PT Tanks upto 220KV & Manufacturing of SMC (Sheet Moulded Compound) DISTRIBUTION BOARDS 1. Complete inhouse Fabrication of CTs & PTs tanks upto 220KV as per drawings. 2. LT DISTRIBUTION BOXES, 25KVA to 315KVA with Kitkat fuse as per drawing in SMC type 3. LTCT Metering Cubicle of any Ratio, class & burden 4. Transformer Protection Boxes 10KVA/16KVA/25KVA/63KVA/100KVA/200KVA/ 400KVA with MCCB as per drawing 5. Single Phase SMC Distribution Box for LT Pole 1.1 kV with clamp, Nuts & Bolts
  • 6. ENERGIZING YOUR FUTURE POWER 6. Three Phase SMC Distribution Box with clamp, Nuts & Bolts 7. LT Distribution Box with MCCB for protection of 16 KVA T/F and Bus Bar for 10No. outgoing consumer connections and suitable to house Energy meter (without Energy meter)
  • 7. LIST OF PLANT AND MACHINERY Sr. No. Name Of Machine/Equipment Brief Specification Qty 1 Coil Drying Oven Drying Oven Temp.150 deg at atmospheric pressure 1 No 2 Drilling Machine Vertical drilling Machine with3/4” Capacity 2 Nos 3 Storage Bins & Racks Industrial storage plastic bins & M.S.Racks to stores material 3 Nos 4 H.V.Coil winding machine (Motorized) Axial winding machine with maximum 250 mm & axial Width 300mm Suitable 2 Nos 5 L .V. Coil winding machine (Motorized) Axial winding machine with maximum 250 mm & axial Width 300mm Suitable Upto 22 swg Copper wire 2 Nos 6 H.V.Coil winding machine (Hand winding) Axial winding machine with maximum 100mm & axial Width 120mm Suitable Upto 42 swg Copper wire 2 Nos 7 Bench voice 12”jaw opening bench voice 2 Nos 8 Hand drill machine 10 mm bore capacity 2 Nos 9 Welding transformer 2 phase, capacity of 250 mm weld current 2 Nos 10 Tooling Kit Various tools for general purpose allen keys, spanner sets 4 Sets 11 Brazing unit 150 Amp brazing Current 1 No 12 Air compressor For painting and finishing of work 1 No 13 Bending Machine Suitable For Fabrication Bending Of Sheet Metal Of Thickness 5 Mm 2 Nos 14 Shearing Machine Suitable For Fabrication Cutting Of Sheet Metal Of Thickness 5 Mm 2 Nos 15 Grinding Machine For De Baring Of Metal Fabrication 3 Nos 16 Welding Machine Welding Of Ms Metal Purpose 4 Nos 17 Oven Heating Purpose 2 Nos 18 Furnace Annealing of Core 1 No
  • 8. LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF RAW MATERIALS) Sr. No. Name Of Machine/Equipment Brief Specification Calibration status Qty 1 Combined Digital CTPT Test System for measurement of ratio and phase angle error CTPT Digital Analyzer Precision for CT Ratio upto 3200A of accuracy upto 0.005 PT for 0 to 207.5VA with printer facility calibrated 1 Set 2 Combined CT Test System for measurement of ratio and phase angle error Test system consisting Of test set CT TEST BRIDGE FOR 5A& 1A calibrated 1 Set 3 Burden Box Burden Box Of 40 VA Of 5 A Burden Box 40 VA Of 1 A calibrated 1 Set 4 Standard CT 0-5-10-15-20-25-30-40-50-60-75- 80-100-125-150-200/5 AMP calibrated 1 Set 0-5-10-15-20-25-30-40-50-60-75- 80-100-125-150-200/1 AMP 1 Set 5 Combined PT Test System for measurement of ratio and phase angle error Test system consisting Of test set PT Test Bridge calibrated 1 Set 6 6 Burden Box For PT Burden Box Of 105 VA Capacity Of Output 110 Volts calibrated 1 Set Burden Box Of 105 VA Capacity Of Output 63.5 Volts calibrated 1 Set 7 Standard PT’s Standard 11kV PT 1ø /2ø Ratio: 11kV / 110V and 11Kv / rt3 /110V /rt3 1 Set Standard 22Kv PT 1ø /2ø Ratio: 22Kv / 110V and 22Kv / rt3 /110V /rt3 calibrated 1 Set Standard 33Kv PT 1ø /2ø Ratio: 33Kv / 110V and 33Kv / rt3 /110V /rt3 calibrated 1 Set 8 High frequency generator set with control panel Coupled motors with panel having frequency meter to get double voltage and frequency for testing of PT’s calibrated 1 Set 9 High voltage AC Test System Test system consisting of HV test transformer 80kv, 4kVA continuous, control desk panel with Ammeter, kV meter, and tripping circuit of 20mA calibrated 1 Set 10 5 kV High voltage AC Test System. Test system consisting of 0-5 kV High voltage Transformer, Manual voltage regulator calibrated 1 Set 11 Set Of Voltmeter Portable type precision type voltmeter RANGE: COM –75-150-300 VOLTS RANGE; COM-150-300-600 VOLTS calibrated 4 Nos 12 Set Of Ammeter Portable type precision type voltmeter RANGE: COM-5A-10A-25A-50A- 100A RANGE: COM-500ma- 1A –5A calibrated 4 Nos
  • 9. LIST OF EQUIPMENTS FOR TESTING (INCLUDING INSPECTION OF RAW MATERIALS) Sr. No. Name Of Machine/Equipment Brief Specification Calibration status Qty 12 Current Source 220V/0-1500 amps with suitable taps and capacity of 3.5 kVA calibrated 1 Set 13 Resistance Measuring Bridge 4 Terminal Milli ohmmeter from 199.9 micro ohm to 19.9 kilo Ohms calibrated 1 No 14 Polarity Meter General Purpose Analog Meter calibrated 3 Nos 15 Voltage Regulator 0-415n Volts output 28A. Auto Transformer input 415 volts 3 PHASE calibrated 2 Nos 16 Continuity Meter General Purpose Analog Multimeter calibrated 1 No 17 Digital General purpose Multimeter General purpose Multimeter with facilities of AC DC voltage measurement, Ammeters Resistance Measurement calibrated 2 Nos 18 Megger Meter 5 kV MEGGER to measure insulation resistance value calibrated 2 Nos 19 Clip – On Meter MAKE MECO 0– 1000 Amp, 750 Volts calibrated 1 No
  • 10. QUALITY SYSTEMS AND PROCEDURES 1. BROUGHT OUT ITEMS (RAW MATERIALS) 1.1. COPPER - Maintaining Test Report for purchase from standard manufacturers - Testing class of insulation of enamel covering by performing temperature test - Electrical Breakdown Value (BDV) Test of enamel covering - Maintaining records of each spool used for individual job 1.2. PAPER - Maintaining Test Report for purchase from standard manufacturers - Testing class of insulation by carrying temperature test - Electrical Breakdown Value (BDV) Test 1.3. OIL - Maintaining Test Report for purchase from standard manufacturers - Electrical Breakdown Value (BDV) Test 1.4. CORE - Maintaining Test Report for purchase from standard manufacturers - Verifying the grade of material - Checking of Knee Point Voltage (SATURATION OF CORE) 2. IN HOUSE TEST (SEMI FINISHED & FINISHED GOODS) 2.1. COIL - Resistance Of Coil - Maintaining records of coil used for each job - Examining dimensional records of coil - Maintaining records of worker, responsible for the winding 2.2. SEMI FINISHED & FINISHED GOODS - Maintaining test report of SEMI FINISHED & FINISHED GOODS - Analyzing the reports of failures in intermediate stages and taking corrective measures accordingly - Analyzing the reports of failures in final stage and taking corrective measures accordingly - Examining the final reports before dispatch 3. EQUIPMENTS 3.1. TEST EQUIPMENT & MACHINERIES - Periodically calibrating and reconditioning of test equipment and machineries from standard government and private labs, required for testing in the production process. 3.2. PERIODICAL MAINTENANCE OF PLANT AND MACHINERIES 4. TESTS 4.1. TYPE TEST - Timely performing the type test of the manufactured product in N.A.B.L accribated labs like E.R.D.A (Electronic Research and Development Association) and C.P.R.I (Central Power and Research Institute).
  • 11. PRODUCT PROFILE CURRENT TRANSFORMER Our all the Epoxy Resin Cast Instrument Transformers & Epoxy Cast Components are Manufactured through Automatic Machine. APPLICATION –Direct measurement of current in high voltage & high current system is not possible because of difficulty in electrical isolation of measuring instruments. Because of its high value,it is also not possible to use current flowing directly to the system, so that current transformer are used to step down the high system current into low system measuring current with their proportionate ratio. due to this it is possible to measure high system current by using standard measuring instruments & relays, also its isolate meters,relays from high voltage systems. VARIOUS TYPES OF CURRENT TRANSFORMERS Ring Type Current Transformers : A Current Transformer which has an window in the center to accommodate a primary conductor (busbar or cable) through it. Bar -PrimaryCurrent Transformers : A Current Transformer in which the primary winding consists of bar of suitable size and it is an integral part of the CT. Wound Type Current Transformers : A Current Transformer having a primary winding of more than one full turn wound on the core. Interposing Current Transformers : These Current Transformers are used in conjunction with main CTs to alter the ratio of main CT or to provide isolation to meters or relays from main CTs secondary circuit. Primary current of these CTs are generally lower than 1 0 amp. Due to which they are always wound primary type. Summation Current Transformers :W hen current flowing, in more than one feeder is required to be metered summation current transformer are used. These Current Transformers are provided with more than one primary winding and one common secondary. Bushing Type or Busduct Current Transformers : These Current Transformers are Ring type construction & can be mounted on Busduct or Bushing turrert of power transformer. Core Balance Current Transformers : These are ring type Current Transformers & suitable for the measurement of the sum of three phase currents in a 3-ph cable. Under normal operating conditions this sum is zero. In the event of an earth-fault the sum of the current is equal to the zero sequence current. .
  • 12. RESIN CAST CURRENT TRANSFORMER Technical Specification As Per IS : 2705 RANGE – 11, 22 & 33 KV ACCURACY CLASS – 0.2 & 0.5 SPECIAL ACCURACY CLASS – 0.2S & 0.5S IS : 2705 General Particulars 11KV 22KV 33 KV Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) Power frequencydry/ wet withstand voltage on primarywinding for one minute 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) Lightning Impulse withstand voltage (1.2 x 50 µ s ) 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) PD measuring Voltage / Permissible Voltage 7.6/50 15.2/50 23.0/50 Specific Particulars Rated Transformation Ratio As per customer requirement (in Amp.) Rated PrimaryCurrent Upto 2000 Amp. Rated SecondaryCurrent 1 Amp. 5 Amp. 0.577 Amp. Short Time Thermal Current (Ith) As per customer requirement. In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal to the system fault level whichever is lower. KA ( r.m.s. ) Short Time Dynamic Current 2.5 X Ith KA (Peak) Number of Cores Upto 3 cores Output Burden Upto 60VA, 0.8 pf Lagging AccuracyClass For Metering : 0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00. For Protection: 5P, 10P, 15P & PS IAF, ALF, Knee Point Voltage, Exciting Current & Resistance As per customer requirement / Design Constraints Type of construction As Per Panel Conditions(Customer Requirement)
  • 13. OIL COOLED CURRENT TRANSFORMER Technical Specification As Per IS : 2705 General Particulars 11KV 22KV 33 KV 66 KV Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) 72 KV (r.m.s.) Power frequency dr y/ wet withstand voltage on primarywinding for one minute 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) 150 KV ( r.m.s.) Lightning Impulse withstand voltage (1.2 x 50 µ s ) 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) 350 KV ( r.m.s.) Specific Particulars Rated Transformation Ratio As per customer requirement (in Amp.) Rated PrimaryCurrent Upto 2000 Amp. Rated Secondary Current 1 Amp. 5 Amp. 0.577 Amp. Short Time Thermal Current (Ith) As per customer requirement. In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal to the system fault level whichever is lower. KA ( r.m.s. ) Short Time Dynamic Current 2.5 X Ith KA (Peak) Number of Cores Upto 5 cores Output Burden Upto 60VA, 0.8 pf Lagging AccuracyClass For Metering : 0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00. For Protection: 5P, 10P, 15P & PS IAF, ALF, Knee Point Voltage, Exciting Current & Resistance As per customer requirement / Design Constraints Type of construction Dead / Bottom Tank or Live / Top Tank
  • 14. POTENTIAL TRANSFORMER APPLICATION – Direct measurement of voltage in high voltage & high current system is not possible because of difficulty in electrical isolation of measuring instruments. Because of its high value, it is also not possible to use voltage directly to the system, so that Potential transformer are used to step down the high system voltage into low system measuring voltage with their proportionate ratio. due to this it is possible to measure high system voltage by using standard measuring instruments & relays, also its isolate meters, relays from high voltage systems and also to sense abnormalities in voltage & give signal to protective relay to isolate the defective system. RESIN CAST POTENTIAL TRANSFORMER RANGE – 11, 22 & 33 KV ACCURACY CLASS – 0.2 & 0.5 SPECIAL ACCURACY CLASS – 0.2S & 0.5S IS : 3156 Technical Specification As Per IS : 3156 General Particulars 11KV 22KV 33 KV Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) Power frequencydry/ wet withstand voltage on primarywinding for one minute 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) Lightning Impulse withstand Voltage ( 1.2 x 50 µ s ) 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) PD measuring Voltage / Permissible Voltage 7.6/50 15.2/50 23.0/50 Specific Particulars Number of Phases 3 or 1 unearthed or earthed Rated Transformation Voltage Ratio As per customer requirement Number of SecondaryWindings Upto 3 Output Burden Upto 100VA AccuracyClass For Metering : 0.2, 0.5 & 1.0 For Protection: 3P, 6P Voltage Factor 1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for 8 hours
  • 15. 0IL COOLED POTENTIAL TRANSFORMER OIL COOLED POTENTIAL TRANSFORMERS Technical Specification As Per IS : 3156 General Particulars 11KV 22KV 33 KV 66 KV Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) 72 KV (r.m.s.) Power frequency dry/ wet withstand voltage on primary winding for one minute 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) 150 KV ( r.m.s.) Lightning Impulse withstand Voltage ( 1.2 x 50 µ s ) 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) 350 KV ( r.m.s.) Specific Particulars Number of Phases 3 or 1 unearthed or earthed Rated Transformation Voltage Ratio As per customer requirement Number of SecondaryWindings Upto 3 Output Burden Upto 500VA AccuracyClass For Metering : 0.2, 0.5,1.0 & 3.0 For Protection: 3P, 6P Voltage Factor 1.2 Continuous & 1.5 for 30 Sec or 1.9 for 30 Sec or 1.9 for 8 hours
  • 16. COMBINED CTPT SET APPLICATION- Combined CTPT Metering Units that are available up to 33 kV class are manufactured specifically to meet the needs of Electricity Supply and captive generating units. The C.T.-P.T. metering sets of this type as the name suggests are used for measurement of power on high voltage side. The C.T.-P.T. sets are installed before the main transformer and the main line goes through C.T.-P.T. set to the main transformer. Metering equipment is connected to the secondary side of the C.T.-P.T. set. As the accuracy of the C.T.-P.T. set is high & as it is connected before the transformer, measurement of power is much more accurate compared to the metering done on L.T. side, the transformer losses are also included in the measurement. OIL COOLED CTPT SET RESIN CAST 3 Ø PT Technical Specification For Oil Cooled CTPT Set As Per IS:2705 & IS:3156 General Particulars 11KV 22KV 33 KV Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) Power frequencydry/ wet withstand voltage on primarywinding for one minute 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) Lightning Impulse withstand Voltage ( 1.2 x 50 µ s ) 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) System Particulars 3 Phase 4 Wire with Isolated / Floating neutral as well as solidlyearthed. 3 Nos. CTs & 1 No. 3 - Phase PT 3 Phase 4 Wire with Isolated / Floating neutral as well as solidlyearthed. 2 Nos. CTs & 1 No. 3 - Phase PT Specific Particulars Short Time Thermal Current (Ith) As per customer requirement. In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal to the system fault level whichever is lower. KA ( r.m.s. ) Output 10 VA to 100 VA for PT and 5 VA to 30 VA for CT AccuracyClass 0.2S, 0.2, 0.5S, 0.5, 1.0 for CT. and 0.2, 0.5 & 1.0 for PT SecondaryCurrent (CT) 1 Amp or 5 Amp SecondaryVoltage (VT) 110 Ph-Ph or 110/v3 V, Ph-Neutral PrimaryCurrent (CT) As per customer requirement. PrimaryVoltage (VT) 11KV, 22KV, 33KV for 3-Phase PT 11/v3, 22/v3, 33/v3 for 1-Phase PT
  • 17. Technical Specification For resin cast CTPT Set As Per IS:2705 & IS:3156 General Particulars 11KV 22KV 33 KV Highest System Voltage( H.S.V.) 12 KV ( r.m.s.) 24 KV ( r.m.s.) 36 KV (r.m.s.) Power frequencydry/ wet withstand voltage on primarywinding for one minute 28 KV ( r.m.s.) 50 KV ( r.m.s.) 70 KV ( r.m.s.) Lightning Impulse withstand Voltage ( 1.2 x 50 µ s ) 75 KV ( r.m.s.) 125 KV ( r.m.s.) 170 KV ( r.m.s.) PD measuring Voltage / Permissible Voltage 7.6/50 15.2/50 23.0/50 System Particulars 3 Phase 4 Wire with Isolated / Floating neutral as well as solidlyearthed. 3 Nos. CTs & 1 No. 3 - Phase PT 3 Nos. CTs & 3 Nos. 1 - Phase PT 3 Phase 4 Wire with Isolated / Floating neutral as well as solidlyearthed. 2 Nos. CTs & 1 No. 3 - Phase PT 2 Nos. CTs & 3 Nos. 1 - Phase PT Specific Particulars Short Time Thermal Current (Ith) As per customer requirement. In general CT is to be specified with STF of 100 for 1 Sec. or STC (lth) equal to the system fault level whichever is lower. KA ( r.m.s. ) Output 10 VA to 100 VA for PT 5 VA to 30 VA for CT AccuracyClass 0.2S, 0.2, 0.5S, 0.5, 1.0 for CT. 0.2, 0.5 & 1.0 for PT SecondaryCurrent (CT) 1 Amp or 5 Amp SecondaryVoltage (VT) 110 Ph-Ph or 110/v3 V, Ph-Neutral PrimaryCurrent (CT) As per customer requirement. PrimaryVoltage (VT) 11KV, 22KV, 33KV for 3-Phase PT 11/v3, 22/v3, 33/v3 for 1-Phase PT
  • 18. SL. Particulars Unit Description 1 Type of Box Sheet Metal or SMC 2 Type of CT Epoxy Resin Cast Bar Primary L.T.C.T 3 Operating System Voltage V 230 , 440 4 Power Frequency Dry withstand Voltage KVp(rms) 3 to 6 5 Transformation ratio Amp 50 to 1200 or as per requirement 6 Rated Secondary Current Amp 5.0 7 Fault Level of CT KA upto 6 KA for 1 or 3 sec 8 No of CT no 4 Nos for 3Phase 4Wire System 3 Nos for 3Phase 3Wire System 9 Output Burden VA Upto 30 at 0.8 pF lag. 10 Accuracy class - Low Tension Pilfer Resistant Metering Cubicle Types:- L.T to 33 KV Voltages Class 1/2/3 one to Five core available Various outline Size as per Customer requirement Bar and Wound primary Type Features:- Compact in design, Low cost and maintenance free. Used mainly for outdoor LT metering on poles. Separate Meter compartment and CT compartment. CT's are epoxy molded to avoid any pilferage. CT's are provided with various inner diameter according to requirement of cable size. Complete dust & vermin proof confirming to IP55 with locking and sealing arrangement.. No secondary circuit wires are accessible outside which avoids chances of energy theft. Stable accuracy over life time. Provision of installing modem inside the cubicle provided Non hygroscopic CT's. Application:- Precision check metering, control indication... Largely used for Metering of LT consumers . Specification
  • 19. SL. Particulars 11 KV 15 KV 22 KV 33 KV 1 Highest System Voltage kV 12 17 24 36 2 Power Freq dry/wet withstand voltage KVp rms 28 36 50 70 3 Lightning Impulse Voltage 1.2/50 µs KVp 75 110 125 170 4 Partial Discharge Measuring Voltage/ Limit. KV/pC 7.6KV/50pC 10.8KV/50pC 15.2KV / 50pC 23KV / 50pC 5 Transformation ratio Amp As per customer requirement. 6 Rated Primary Current Amp Upto 1000 Amp 7 Rated Secondary Current Amp 1.0, 5.0 8 Rated Secondary Voltage Volts 110/√3 for Ph-Neutral, 110 for Ph-Ph 9 Rated Secondary Current Amp 1.0, 5.0 10 Short Time Current Rating KA(rms) Upto 25KA for 1 or 3 sec 11 Out put Burden VA Upto 30 at 0.8 pf lag for CT Upto 100 at 0.8 pf lag for PT 12 Accuracy class - For CT - 0.2, 0.2s, 0.5, 0.5s, 1.0, 3.0 & 5.0 For VT - 0.2, 0.5, 1.0 EPOXY RESIN CAST PILFER RESISTANT METERING CUBICLE/PANEL Types:- 11KV to 33KV Voltage Class 3 no C.T's & 3 No Single Phase VT'S 3 no C.T's & 1 No Three Phase VT'S Features:- Compact in design, Low cost and maintenance free. Separate Meter compartment and CT-PT compartment. Available in 3Phase 3W ire and 3Phase 4Wire systems. CT's & PT's are epoxy molded to avoid any pilferage. Complete dust & vermin proof confirming to IP55 with locking and sealing arrangement. No secondary circuit wires are accessible outside which avoids chances of energy theft. Stable accuracy over life time. Designed mainly for Indoor applications Non hygroscopic CT's & PT's. Application:- Precision Revenue metering, control indication. Used for Double Metering of Transformers. Used on Feeder Metering for energy accounting. Specification
  • 20. Office address : F-285, UPSIDC, Khichra Industrial Area, Meerut- Guwahati Road, Ghaziabad – 201001, UP, India Phone No. : +91-9210927863 / +91-9313115696/ +91-9868667484 E-mail ID : mew.ctpt@gmail.com / luckyindiapowersolutions@gmail.com / info@luckyindiapowersolution.com Contact Details : Mr. Shokaut Ali / Mr. Sharafat Ali Phone No. : +91-9313115696 / + 91-9868667484 E-mail ID : mews.ctpt@gmail.com / luckyindiapowersolutions@gmail.com / anjni10@rediffmail.com Mr. DINESHGOEL Phone No. : +91-9818884692 / +91-9012184692 E-mail ID : dgoel90@gmail.com / anjni10@rediffmail.com http://www.indiamart.com/jayaelectricals
  • 22.
  • 23.
  • 24.
  • 25.
  • 26. -
  • 27. G-99 & G-3, UPSIDC Industrial Area, Phase-I, M. G. Road, Ghaziabad – 201015, Uttar Pradesh, India Tel.: +91-7088081626 / +91-9313115696 / +91-9818884692 Email: anjni10@rediffmail.com / luckyindiapowersolutions@gmail.com / dgoel90@gmail.com http://www.indiamart.com/jayaelectricals