This document summarizes a study comparing the seismic analysis of a 5-story building with and without floating columns. Model 1 is a normal building without floating columns and serves as the baseline. Model 2 has interior columns removed at the ground floor, creating floating columns, but fails structural analysis. Model 3 modifies Model 2 by increasing beam and column sizes to make it structurally sound. Analysis found Model 3 had lower displacements than Model 1 under seismic loads, but required 44% more steel and 22% more concrete, making it uneconomical compared to the normal building structure. The conclusion is that floating column buildings should be avoided due to increased construction costs and improved seismic performance can be obtained through other techniques than floating columns.