Submit Search
Upload
IRJET- A Review on Distribution System with Harmonic Reduction
•
0 likes
•
22 views
IRJET Journal
Follow
https://irjet.net/archives/V5/i12/IRJET-V5I12227.pdf
Read less
Read more
Engineering
Report
Share
Report
Share
1 of 4
Download now
Download to read offline
Recommended
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET Journal
Â
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
IJAPEJOURNAL
Â
Harmonic enhancement in microgrid with applications on sensitive loads
Harmonic enhancement in microgrid with applications on sensitive loads
IJECEIAES
Â
Harmonic Mitigation using Modified Synchronous Reference Frame Theory
Harmonic Mitigation using Modified Synchronous Reference Frame Theory
IRJET Journal
Â
IRJET- Distribution System Planning using Network Reconfiguration for Loss R...
IRJET- Distribution System Planning using Network Reconfiguration for Loss R...
IRJET Journal
Â
Optimize Controlling of Active Filters Controlled by Pi Controller
Optimize Controlling of Active Filters Controlled by Pi Controller
IRJET Journal
Â
IRJET- Feature Ranking for Energy Disaggregation
IRJET- Feature Ranking for Energy Disaggregation
IRJET Journal
Â
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
IJERA Editor
Â
Recommended
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET Journal
Â
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
Harmonic Voltage Distortions in Power Systems Due to Non Linear Loads
IJAPEJOURNAL
Â
Harmonic enhancement in microgrid with applications on sensitive loads
Harmonic enhancement in microgrid with applications on sensitive loads
IJECEIAES
Â
Harmonic Mitigation using Modified Synchronous Reference Frame Theory
Harmonic Mitigation using Modified Synchronous Reference Frame Theory
IRJET Journal
Â
IRJET- Distribution System Planning using Network Reconfiguration for Loss R...
IRJET- Distribution System Planning using Network Reconfiguration for Loss R...
IRJET Journal
Â
Optimize Controlling of Active Filters Controlled by Pi Controller
Optimize Controlling of Active Filters Controlled by Pi Controller
IRJET Journal
Â
IRJET- Feature Ranking for Energy Disaggregation
IRJET- Feature Ranking for Energy Disaggregation
IRJET Journal
Â
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
Performance Analysis Of PV Interfaced Neural Network Based Hybrid Active Powe...
IJERA Editor
Â
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)
IJERD Editor
Â
Mitigation of the Harmonics under Reactive Power Compensation by SHPF-TCR Usi...
Mitigation of the Harmonics under Reactive Power Compensation by SHPF-TCR Usi...
IJERA Editor
Â
IRJET- Voltage Profile and Loss Reduction Enhancement by Optimal Placement of...
IRJET- Voltage Profile and Loss Reduction Enhancement by Optimal Placement of...
IRJET Journal
Â
Power system restoration in distribution network through reconfiguration usin...
Power system restoration in distribution network through reconfiguration usin...
eSAT Journals
Â
Power Quality Improvement in 3-Φ Power System with Shunt Active filter using ...
Power Quality Improvement in 3-Φ Power System with Shunt Active filter using ...
AI Publications
Â
Power-Quality-Improvement-Using-PI-and-Fuzzy-Logic-Controllers-Based-Shunt-Ac...
Power-Quality-Improvement-Using-PI-and-Fuzzy-Logic-Controllers-Based-Shunt-Ac...
Atul Sharma
Â
Assessment of Energy Efficiency of a Large Interconnected Distribution System...
Assessment of Energy Efficiency of a Large Interconnected Distribution System...
paperpublications3
Â
Reliability Indices Evaluation of a Real Time Rural Radial Distribution Feeder
Reliability Indices Evaluation of a Real Time Rural Radial Distribution Feeder
IOSR Journals
Â
IRJET- Simulation and Experimental Verification of Single Phase Unity Power F...
IRJET- Simulation and Experimental Verification of Single Phase Unity Power F...
IRJET Journal
Â
IRJET-Power Quality Effects on Nonlinear Loads
IRJET-Power Quality Effects on Nonlinear Loads
IRJET Journal
Â
improvement of electrical power quality using series active and shunt passive...
improvement of electrical power quality using series active and shunt passive...
Vikram Rawani
Â
Grid Interconnection of Renewable Energy Sources at the Distribution Level Wi...
Grid Interconnection of Renewable Energy Sources at the Distribution Level Wi...
Pradeep Avanigadda
Â
A New Methodology for Active Power Transmission Loss Allocation in Deregulate...
A New Methodology for Active Power Transmission Loss Allocation in Deregulate...
IJECEIAES
Â
Network Modelling for Harmonic Studies
Network Modelling for Harmonic Studies
Power System Operation
Â
Power-Quality Improvement Features In Grid Interconnection of Wind Energy Sou...
Power-Quality Improvement Features In Grid Interconnection of Wind Energy Sou...
AM Publications
Â
Ee33783786
Ee33783786
IJERA Editor
Â
OPTIMAL PLACEMENT AND SIZING OF CAPACITOR BANKS BASED ON VOLTAGE PROFILE AND ...
OPTIMAL PLACEMENT AND SIZING OF CAPACITOR BANKS BASED ON VOLTAGE PROFILE AND ...
Prashanta Sarkar
Â
El34831851
El34831851
IJERA Editor
Â
Comparative of Conventional and Intelligence Controller based Hybrid Generati...
Comparative of Conventional and Intelligence Controller based Hybrid Generati...
IJERD Editor
Â
Dual Active Power Filter For LCL Resonance In Grid-Connected Voltage-Source C...
Dual Active Power Filter For LCL Resonance In Grid-Connected Voltage-Source C...
IJARIDEA Journal
Â
J0361059064
J0361059064
ijceronline
Â
research on journaling
research on journaling
rikaseorika
Â
More Related Content
What's hot
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)
IJERD Editor
Â
Mitigation of the Harmonics under Reactive Power Compensation by SHPF-TCR Usi...
Mitigation of the Harmonics under Reactive Power Compensation by SHPF-TCR Usi...
IJERA Editor
Â
IRJET- Voltage Profile and Loss Reduction Enhancement by Optimal Placement of...
IRJET- Voltage Profile and Loss Reduction Enhancement by Optimal Placement of...
IRJET Journal
Â
Power system restoration in distribution network through reconfiguration usin...
Power system restoration in distribution network through reconfiguration usin...
eSAT Journals
Â
Power Quality Improvement in 3-Φ Power System with Shunt Active filter using ...
Power Quality Improvement in 3-Φ Power System with Shunt Active filter using ...
AI Publications
Â
Power-Quality-Improvement-Using-PI-and-Fuzzy-Logic-Controllers-Based-Shunt-Ac...
Power-Quality-Improvement-Using-PI-and-Fuzzy-Logic-Controllers-Based-Shunt-Ac...
Atul Sharma
Â
Assessment of Energy Efficiency of a Large Interconnected Distribution System...
Assessment of Energy Efficiency of a Large Interconnected Distribution System...
paperpublications3
Â
Reliability Indices Evaluation of a Real Time Rural Radial Distribution Feeder
Reliability Indices Evaluation of a Real Time Rural Radial Distribution Feeder
IOSR Journals
Â
IRJET- Simulation and Experimental Verification of Single Phase Unity Power F...
IRJET- Simulation and Experimental Verification of Single Phase Unity Power F...
IRJET Journal
Â
IRJET-Power Quality Effects on Nonlinear Loads
IRJET-Power Quality Effects on Nonlinear Loads
IRJET Journal
Â
improvement of electrical power quality using series active and shunt passive...
improvement of electrical power quality using series active and shunt passive...
Vikram Rawani
Â
Grid Interconnection of Renewable Energy Sources at the Distribution Level Wi...
Grid Interconnection of Renewable Energy Sources at the Distribution Level Wi...
Pradeep Avanigadda
Â
A New Methodology for Active Power Transmission Loss Allocation in Deregulate...
A New Methodology for Active Power Transmission Loss Allocation in Deregulate...
IJECEIAES
Â
Network Modelling for Harmonic Studies
Network Modelling for Harmonic Studies
Power System Operation
Â
Power-Quality Improvement Features In Grid Interconnection of Wind Energy Sou...
Power-Quality Improvement Features In Grid Interconnection of Wind Energy Sou...
AM Publications
Â
Ee33783786
Ee33783786
IJERA Editor
Â
OPTIMAL PLACEMENT AND SIZING OF CAPACITOR BANKS BASED ON VOLTAGE PROFILE AND ...
OPTIMAL PLACEMENT AND SIZING OF CAPACITOR BANKS BASED ON VOLTAGE PROFILE AND ...
Prashanta Sarkar
Â
What's hot
(17)
International Journal of Engineering Research and Development (IJERD)
International Journal of Engineering Research and Development (IJERD)
Â
Mitigation of the Harmonics under Reactive Power Compensation by SHPF-TCR Usi...
Mitigation of the Harmonics under Reactive Power Compensation by SHPF-TCR Usi...
Â
IRJET- Voltage Profile and Loss Reduction Enhancement by Optimal Placement of...
IRJET- Voltage Profile and Loss Reduction Enhancement by Optimal Placement of...
Â
Power system restoration in distribution network through reconfiguration usin...
Power system restoration in distribution network through reconfiguration usin...
Â
Power Quality Improvement in 3-Φ Power System with Shunt Active filter using ...
Power Quality Improvement in 3-Φ Power System with Shunt Active filter using ...
Â
Power-Quality-Improvement-Using-PI-and-Fuzzy-Logic-Controllers-Based-Shunt-Ac...
Power-Quality-Improvement-Using-PI-and-Fuzzy-Logic-Controllers-Based-Shunt-Ac...
Â
Assessment of Energy Efficiency of a Large Interconnected Distribution System...
Assessment of Energy Efficiency of a Large Interconnected Distribution System...
Â
Reliability Indices Evaluation of a Real Time Rural Radial Distribution Feeder
Reliability Indices Evaluation of a Real Time Rural Radial Distribution Feeder
Â
IRJET- Simulation and Experimental Verification of Single Phase Unity Power F...
IRJET- Simulation and Experimental Verification of Single Phase Unity Power F...
Â
IRJET-Power Quality Effects on Nonlinear Loads
IRJET-Power Quality Effects on Nonlinear Loads
Â
improvement of electrical power quality using series active and shunt passive...
improvement of electrical power quality using series active and shunt passive...
Â
Grid Interconnection of Renewable Energy Sources at the Distribution Level Wi...
Grid Interconnection of Renewable Energy Sources at the Distribution Level Wi...
Â
A New Methodology for Active Power Transmission Loss Allocation in Deregulate...
A New Methodology for Active Power Transmission Loss Allocation in Deregulate...
Â
Network Modelling for Harmonic Studies
Network Modelling for Harmonic Studies
Â
Power-Quality Improvement Features In Grid Interconnection of Wind Energy Sou...
Power-Quality Improvement Features In Grid Interconnection of Wind Energy Sou...
Â
Ee33783786
Ee33783786
Â
OPTIMAL PLACEMENT AND SIZING OF CAPACITOR BANKS BASED ON VOLTAGE PROFILE AND ...
OPTIMAL PLACEMENT AND SIZING OF CAPACITOR BANKS BASED ON VOLTAGE PROFILE AND ...
Â
Similar to IRJET- A Review on Distribution System with Harmonic Reduction
El34831851
El34831851
IJERA Editor
Â
Comparative of Conventional and Intelligence Controller based Hybrid Generati...
Comparative of Conventional and Intelligence Controller based Hybrid Generati...
IJERD Editor
Â
Dual Active Power Filter For LCL Resonance In Grid-Connected Voltage-Source C...
Dual Active Power Filter For LCL Resonance In Grid-Connected Voltage-Source C...
IJARIDEA Journal
Â
J0361059064
J0361059064
ijceronline
Â
research on journaling
research on journaling
rikaseorika
Â
A Review on Unified Power Quality Conditioner for 3P4W System
A Review on Unified Power Quality Conditioner for 3P4W System
IRJET Journal
Â
Simulation of Shunt Active Power Filter Based on p q Theory
Simulation of Shunt Active Power Filter Based on p q Theory
ijtsrd
Â
IRJET- A Review on Hybrid Series and Shunt with Power Quality Monitoring System
IRJET- A Review on Hybrid Series and Shunt with Power Quality Monitoring System
IRJET Journal
Â
IRJET- Review: Active Power Filtering Techniques for Power System
IRJET- Review: Active Power Filtering Techniques for Power System
IRJET Journal
Â
A Review on Improved Secondary Distribution Network for Power Quality in Grid...
A Review on Improved Secondary Distribution Network for Power Quality in Grid...
IRJET Journal
Â
H42013944
H42013944
IJERA Editor
Â
Adaptive Fuzzy PID Based Control Strategy For 3Phase 4Wire Shunt Active Filte...
Adaptive Fuzzy PID Based Control Strategy For 3Phase 4Wire Shunt Active Filte...
IJERA Editor
Â
A CONTROL APPROACH FOR GRID INTERFACING INVERTER IN 3 PHASE 4 WIRE DISTRIBUT...
A CONTROL APPROACH FOR GRID INTERFACING INVERTER IN 3 PHASE 4 WIRE DISTRIBUT...
IJMER
Â
A Fuzzy Based STATCOM Controller for Mitigating Current Harmonics in Grid Int...
A Fuzzy Based STATCOM Controller for Mitigating Current Harmonics in Grid Int...
IJMTST Journal
Â
Power quality improvement in a weak bus system using facts controller
Power quality improvement in a weak bus system using facts controller
eSAT Journals
Â
Influencing Factors on Power Losses in Electric Distribution Network
Influencing Factors on Power Losses in Electric Distribution Network
IJAEMSJORNAL
Â
Study Of Different Passive Filter- A Review
Study Of Different Passive Filter- A Review
IRJET Journal
Â
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET Journal
Â
Harmonic Analysis of Non-Linear Loads in Distribution System and Mitigation U...
Harmonic Analysis of Non-Linear Loads in Distribution System and Mitigation U...
IRJET Journal
Â
A New approach for controlling the power flow in a transmission system using ...
A New approach for controlling the power flow in a transmission system using ...
IJMER
Â
Similar to IRJET- A Review on Distribution System with Harmonic Reduction
(20)
El34831851
El34831851
Â
Comparative of Conventional and Intelligence Controller based Hybrid Generati...
Comparative of Conventional and Intelligence Controller based Hybrid Generati...
Â
Dual Active Power Filter For LCL Resonance In Grid-Connected Voltage-Source C...
Dual Active Power Filter For LCL Resonance In Grid-Connected Voltage-Source C...
Â
J0361059064
J0361059064
Â
research on journaling
research on journaling
Â
A Review on Unified Power Quality Conditioner for 3P4W System
A Review on Unified Power Quality Conditioner for 3P4W System
Â
Simulation of Shunt Active Power Filter Based on p q Theory
Simulation of Shunt Active Power Filter Based on p q Theory
Â
IRJET- A Review on Hybrid Series and Shunt with Power Quality Monitoring System
IRJET- A Review on Hybrid Series and Shunt with Power Quality Monitoring System
Â
IRJET- Review: Active Power Filtering Techniques for Power System
IRJET- Review: Active Power Filtering Techniques for Power System
Â
A Review on Improved Secondary Distribution Network for Power Quality in Grid...
A Review on Improved Secondary Distribution Network for Power Quality in Grid...
Â
H42013944
H42013944
Â
Adaptive Fuzzy PID Based Control Strategy For 3Phase 4Wire Shunt Active Filte...
Adaptive Fuzzy PID Based Control Strategy For 3Phase 4Wire Shunt Active Filte...
Â
A CONTROL APPROACH FOR GRID INTERFACING INVERTER IN 3 PHASE 4 WIRE DISTRIBUT...
A CONTROL APPROACH FOR GRID INTERFACING INVERTER IN 3 PHASE 4 WIRE DISTRIBUT...
Â
A Fuzzy Based STATCOM Controller for Mitigating Current Harmonics in Grid Int...
A Fuzzy Based STATCOM Controller for Mitigating Current Harmonics in Grid Int...
Â
Power quality improvement in a weak bus system using facts controller
Power quality improvement in a weak bus system using facts controller
Â
Influencing Factors on Power Losses in Electric Distribution Network
Influencing Factors on Power Losses in Electric Distribution Network
Â
Study Of Different Passive Filter- A Review
Study Of Different Passive Filter- A Review
Â
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
IRJET- Harmonic Elimination in Three Phase System by Means of Hybrid Active F...
Â
Harmonic Analysis of Non-Linear Loads in Distribution System and Mitigation U...
Harmonic Analysis of Non-Linear Loads in Distribution System and Mitigation U...
Â
A New approach for controlling the power flow in a transmission system using ...
A New approach for controlling the power flow in a transmission system using ...
Â
More from IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
Â
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
Â
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
IRJET Journal
Â
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
IRJET Journal
Â
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
IRJET Journal
Â
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
IRJET Journal
Â
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
IRJET Journal
Â
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
IRJET Journal
Â
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
IRJET Journal
Â
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
IRJET Journal
Â
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
IRJET Journal
Â
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
IRJET Journal
Â
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
IRJET Journal
Â
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
IRJET Journal
Â
React based fullstack edtech web application
React based fullstack edtech web application
IRJET Journal
Â
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
IRJET Journal
Â
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
IRJET Journal
Â
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
IRJET Journal
Â
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
IRJET Journal
Â
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
IRJET Journal
Â
More from IRJET Journal
(20)
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
Â
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
Â
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
Â
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
Â
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
Â
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Â
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Â
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
Â
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
Â
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Â
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
Â
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
Â
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
Â
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
Â
React based fullstack edtech web application
React based fullstack edtech web application
Â
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
Â
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
Â
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Â
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Â
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Â
Recently uploaded
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
hassan khalil
Â
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
Mark Billinghurst
Â
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
NikhilNagaraju
Â
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
Asst.prof M.Gokilavani
Â
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
ssuser7cb4ff
Â
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
RajaP95
Â
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
eptoze12
Â
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
srsj9000
Â
DATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage example
PragyanshuParadkar1
Â
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
Asst.prof M.Gokilavani
Â
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...
asadnawaz62
Â
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
959SahilShah
Â
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Dr.Costas Sachpazis
Â
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
Dr SOUNDIRARAJ N
Â
young call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Service
9953056974 Low Rate Call Girls In Saket, Delhi NCR
Â
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
JoĂŁo Esperancinha
Â
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
roselinkalist12
Â
Past, Present and Future of Generative AI
Past, Present and Future of Generative AI
abhishek36461
Â
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
Chandu841456
Â
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
wendy cai
Â
Recently uploaded
(20)
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
Â
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
Â
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
Â
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
CCS355 Neural Networks & Deep Learning Unit 1 PDF notes with Question bank .pdf
Â
Call Girls Narol 7397865700 Independent Call Girls
Call Girls Narol 7397865700 Independent Call Girls
Â
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
HARMONY IN THE NATURE AND EXISTENCE - Unit-IV
Â
Oxy acetylene welding presentation note.
Oxy acetylene welding presentation note.
Â
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Gfe Mayur Vihar Call Girls Service WhatsApp -> 9999965857 Available 24x7 ^ De...
Â
DATA ANALYTICS PPT definition usage example
DATA ANALYTICS PPT definition usage example
Â
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
CCS355 Neural Network & Deep Learning Unit II Notes with Question bank .pdf
Â
complete construction, environmental and economics information of biomass com...
complete construction, environmental and economics information of biomass com...
Â
Application of Residue Theorem to evaluate real integrations.pptx
Application of Residue Theorem to evaluate real integrations.pptx
Â
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Sachpazis Costas: Geotechnical Engineering: A student's Perspective Introduction
Â
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
UNIT III ANALOG ELECTRONICS (BASIC ELECTRONICS)
Â
young call girls in Green Park🔝 9953056974 🔝 escort Service
young call girls in Green Park🔝 9953056974 🔝 escort Service
Â
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Â
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
INFLUENCE OF NANOSILICA ON THE PROPERTIES OF CONCRETE
Â
Past, Present and Future of Generative AI
Past, Present and Future of Generative AI
Â
An experimental study in using natural admixture as an alternative for chemic...
An experimental study in using natural admixture as an alternative for chemic...
Â
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
Â
IRJET- A Review on Distribution System with Harmonic Reduction
1.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1214 A Review on Distribution System with Harmonic Reduction Tasneem Akhtar1, Varsha Sharma2 1,2Dept. of Electrical Engineering, RSR Rungta College of Engineering, Durg, C.G., India -------------------------------------------------------------------------***------------------------------------------------------------------------ Abstract - In the world of electrical power generation, a main point of consideration has always been to achieve adequate performance in terms of power quality. In this context, an important factor is the generation, management and reduction/compensation of spatial and time harmonics throughout the whole power system. From the first developments in the mid-1800s of electrical power generation and distribution systems, harmonic content improvement and reduction has evolved from a localised generator design problem to an internationally regulated supply characteristic that must be considered at all points of the power distribution network. This paper is thus aimed to be a review of harmonic improvement techniques and methodologies, organised to follow and indicate the development timeline of these methods. Distribution level generation has been chosen as the focus to align with recent changes in grid topology caused by distributed and renewable generation. In this section, the paper begins by detailing the changing nature of power quality in distribution networks followed by a description of the main types of power quality issues and an overview of the key standards governing network limits. The focus then shifts to harmonic reduction procedures and methodologies. A review of harmonic reduction methods based around the design of rotating electrical generators is developed, followed by a review of modern methods applied to new generation systems, such as renewable sources. Keywords- Harmonics, Total Harmonic Distortion (THD), DC Power, Distribution System, Passive Filter, Harmonic Reduction Literature Survey Sanjib Kumar Nandi et al. (2015) Usages of DC power instead of AC power on the secondary distribution system creates a lot of harmonics. Our goal is to eliminate the harmonics onto the system and due to the limited specification of filter it has not been possible to reduce all the harmonics in the secondary distribution system. But we must be more focused to achieve this goal, because large shares of household loads are turning into DC in recent years. If this trend continues, the impact of harmonics on customer end will reach a level which might be detrimental and redundant to both loads and grid. The main objective of this research is to explain the effects of harmonics on the low voltage direct current (LVDC) distribution system and measure the harmonic content present in the network and proposed a recovery method by inserting filter. Due to additional non-linear loads on the LVDC distribution system, a sufficient amount of harmonics will be created. To solve this issue, use of passive harmonic filter is recommended for the DC operated secondary distribution system. Daniel Fallows et al. (2018) This paper provides a comprehensive literature review of techniques for harmonic related power quality improvement of electrical generation systems. An increasing interest in these aspects is due to the ever more stringent power quality requirements, deriving from new grid codes and compliancy standards, aimed at limiting waveform harmonic distortion at all points of the distribution network. Geena Sharma and Kanchan Jaswal (2016) Active power filters are the emerging devices, which can diminish harmonic pollution effectively. Normally, the shunt APF is controlled such that it eliminates the load current harmonics and supplies load reactive power to achieve harmonic free source currents at unity power factor. However, these control objectives cannot be achieved simultaneously when the supply voltages are distorted and unbalanced (non-ideal). Mrs. M. Sindhubala and Ms. Allan Mary George (2013) The principle of this paper is to know the effects of harmonics in a power system and to minimise the effects of the power system harmonics. This distortion will result in low power quality and improved disturbances in power system. So this harmonic technique is used to improve the power quality. The increase in power quality using a technique is explained in detail here. Erwin Normanyo (2013) Three-phase four-wire distribution systems are very common and widely used in commercial and industrial installations and therefore power systems harmonics is an area that merits a great deal of attention.
2.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1215 Advancement in semiconductor devices has fuelled an increase in the use of non-linear loads which are the main causes of harmonic distortion in three-phase, four-wire distribution systems. Mitigation of harmonics in three-phase, four-wire electrical power distribution systems that supply balanced and unbalanced non-linear loads was therefore conducted. This paper proposes an approach to compensate for harmonics in a three-phase four-wire power distribution system. The mitigation principle is described, and some interesting filtering characteristics are discussed. Jonathan K. Piel (2004) Power consumption of harmonic drawing loads is an increasing concern for cost conscious facility managers and engineersThe paper illustrated that up to 8% kW reduction could be realized by eliminating harmonic current at various points in a power distribution system, with the greatest benefits achieved with harmonic mitigation applied at the point of use. The research and results were reached through mathematical modeling of system losses and performance. This paper presents the design and simulation hybrid active filter based on voltage detection consisting of seventh-tuned LC passive power filter and a 3𝜙 active power filter connected in series to mitigate the harmonic propagation under the worst-case situation that is under no load. The filter is connected in parallel to the system. Simulation is carried out for a 415V, 50Hz system in MATLAB. The THD is reduced from 19% without filter to 1.5% with the addition of hybrid filter. Dinari Kiran Kumar et al. (2017) The improvement in technologies over the recent years has led to the increase of power electronic loads in distribution feeders. Thus, leading to increased usage of capacitors for correcting the power factor in distribution systems. This causes harmonic propagation because of resonance amongst line inductances and capacitors used for correcting power factor. This situation is worst during no-load conditions. In real power distribution systems, this situation occurs at night times. To mitigate these harmonics active filters had been proposed and tested [1]-[2]. These active filters act like damping resistor to harmonic frequencies. It’s not economically feasible to install filters at the neighbourhood of each harmonic producing load, to achieve harmonic mitigation throughout the feeder filters must be installed at the end terminal of the distribution feeder [3]. The cost of installing active filters should be taken care by the electricity supply company. Practically size of the active filters is too large for installation on the electric poles. Problems of cost and size can be overcome with the help of a new alternative of shunt hybrid active filter is proposed [4]. The shunt hybrid active power filter is the combination of a tuned passive power filter and an active power filter connected in series with each other. The voltage detection based hybrid power filter acts like damping resistor to the frequencies of the harmonics. Simulation results is obtained for a hybrid active power filter connected to a 415V, 50Hz feeder simulator. The complete control of the filter is digital. Md. Siddikur Rahman (2017) Among all the existing network technologies, LVDC system is one of the emanating technology renovations for Smart Grid application to the distribution of electricity and a highly interesting challenge [1]. The salient purposes beyond this development of the LVDC network is to enhance the power quality and furnish security experienced by the end users of the electricity for ameliorating the distribution economy [1]. This pledge flexible and robust coupling point for small scale generation and evolve infrastructure for interactive and intelligent distribution network [1, 2]. The distribution transformer is one of the key parts of LVDC system [3]. The nonlinear nature of the load has generated harmonic currents which may cause problems in the power system and overheating transformers. Nonlinear loads have generated harmonic currents which are flown from the load towards the power source, following the least impedance paths [4]. Modern electrical system consists of a vast amount of nonlinear loads which causes disturbances in DC current. Commercial buildings often have a large amount of nonlinear electronic loads such as lighting, computers, monitors and adjustable-speed drives for air conditioning. Due to this huge presence of nonlinear loads, electromagnetic-compatibility and power quality problems may occur [5]. For which power system suffers from unfavorable consequences and may damage electrical equipment’s. IEEE Standard 519-1992 specifies limits for each harmonic up to the 35th and limits the total harmonic distortion (THD) to 5% [6]. EN 50160 limits the THD to 8% and the unbalance to 2% [7]. This problem can require special consideration to serve non-linear loads with a reduce amount of harmonic distortion. Using various techniques power distribution system’s Harmonic distortion might be restrained [2]. Previously, researches have been conducted on load behavior and harmonic contribution in various sectors of the power system. For instance, The LVDC power distribution network concept is presented [8]. Harmonic analysis and DC operated electrical system with distributed resources for recovery from the effects of harmonics and closely relevant criteria have been proposed in [9, 10, 11 and 12]. The LVDC distribution system concept has been developed in [13]. Passive filter installation for reducing harmonic in single phase motor, varying load has been introduced.
3.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1216 Allan Mary George et al. (2014) The term harmonics referred to Power quality in ideal world would mean how pure the voltage is, how pure the current waveform is in its sinusoidal form. Power quality is very important to commercial and industrial power system designs.A perfect sinusoidal waveform must be without any kind of distortion. If there is any distortion in terms of current or voltage it will be called as harmonic distortion. This distortion can be due to many reasons. Now - a- days, engineers try very hard to derive some methods to reduce the harmonic distortion. Because of the simple and conservative designs of power systems, harmonic distortion was less before. but now the harmonic distortion has increased very well due to the complex designs in the industry. This project helps us to understand the effects of harmonics in power system and explains the way to reduce it. From this project we can also be able to know the important problems related with power quality and the disturbances to the power system. This project includes the techniques to reduce the harmonics and to improve the power quality. It also includes simulation for the same. This project also explains different types of inverters that are used in the Power System. During the transformation from DC to AC, harmonics affect the power quality a lot. How harmonic reduction will improve the power quality will be explained in detail as shown. Daniel J. Carnovale In the near future, predictions concerning the “digital economy” indicate that more than 50% of all power consumed in the North America will be through power electronic devices including switch-mode power supplies, variable frequency drives, and other power electronic equipment. Harmonics drawn by these loads have significantly changed the power system requirements to protect these loads and to protect the system from these loads. The function of the distribution system is to deliver fundamental current to the terminals of the load. Generally, fundamental current is the only component of current which performs useful work. In contrast, harmonic current is simply the “by-product” of the way non-linear loads draw current and are not necessary to perform useful work. A.Kumar et al. (2017) The improvement in technologies over the recent years has led to the increase of power electronic loads in distribution feeders. Thus, leading to increased usage of capacitors for correcting the power factor in distribution systems. This causes harmonic propagation because of resonance amongst line inductances and capacitors used for correcting power factor. This situation is worst during no-load conditions. In real power distribution systems, this situation occurs at night times. To mitigate these harmonics active filters had been proposed and tested [1]-[2]. These active filters act like damping resistor to harmonic frequencies. It’s not economically feasible to install filters at the neighbourhood of each harmonic producing load, to achieve harmonic mitigation throughout the feeder filters must be installed at the end terminal of the distribution feeder [3]. The cost of installing active filters should be taken care by the electricity supply company. Practically size of the active filters is too large for installation on the electric poles. Problems of cost and size can be overcome with the help of a new alternative of shunt hybrid active filter is proposed [4]. The shunt hybrid active power filter is the combination of a tuned passive power filter and an active power filter connected in series with each other. The voltage detection based hybrid power filter acts like damping resistor to the frequencies of the harmonics. Simulation result is obtained for a hybrid active power filter connected to a 415V, 50Hz feeder simulator. The complete control of the filter is digital Conclusion In electrical power system, harmonic current pollution is a one of the most major power quality problem that need to be solve to get the good or excellent power supply. This make power quality is really important in the distribution system. In the other side, there also several phenomena that can cause an interruption or disturbance due to the power supply which is overvoltage , voltage sags, voltage surges and harmonic. Current harmonic distortion can be identifying due to the non- linear relationship between the voltage harmonic and percentage load of the common harmonic producing device like electrical equipment in the office building [1] . As already know that harmonic distortion is a pollution form of the electric network which is being problematic when the sum of harmonic current is biggest compare to the boundary-values. In office building, the electrical circuits that were designed for a relative plug load may be overload by electronic equipment. This because there are growing and implementation in electronic equipment that widely used nowadays. Electronic equipment like fax machine, printers, computers and air conditioner actually can provide a significant increase in office productivity. Besides that, this equipment will turn on a high percentage of overall demand factors. In the same time, it’s also allowed maximum load as a per cent of connected load. Building wiring also can associate the most losses of the harmonic.
4.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 05 Issue: 12 | Dec 2018 www.irjet.net p-ISSN: 2395-0072 © 2018, IRJET | Impact Factor value: 7.211 | ISO 9001:2008 Certified Journal | Page 1217 References 1. Sanjib Kumar Nandi, Md. Siddikur Rahman, Ridown Rashid Riadh, “Harmonic Analysis on LVDC Distribution System and Passive Filter Techniques for Harmonic Reduction”, 978-1-4673-9257-0/15/$31.00 ©2015 IEEE. 2. Daniel Fallows 1*, Stefano Nuzzo 1, Alessandro Costabeber 1, Michael Galea, “Harmonic Reduction Methods for Electrical Generation: A Review”. 3. Geena Sharma1, Kanchan Jaswal2, “Harmonic Reduction using Shunt Active Power Filter” International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering, Vol. 5, Issue 6, June 2016. 4. Mrs. M. Sindhubala, Ms. Allan Mary George, “Harmonic Reduction in Power System” Vol. 3, Issue 6, Nov-Dec 2013, pp.712-714. Int. Journal of Engineering Research and Applications. 5. Erwin Normanyo, “Mitigation of Harmonics in a Three-Phase, Four-Wire Distribution System using a System of Shunt Passive Filters”, International Journal of Engineering and Technology Volume 2 No. 5, May, 2012. 6. Jonathan K. Piel and Daniel J. Carnovale, P.E. “ECONOMIC AND ELECTRICAL BENEFITS OF HARMONIC REDUCTION METHODS IN COMMERCIAL FACILITIES” PU00904002E dated 07/04. 7. Ashitha S Kumar, Dinari Kiran Kumar, A.Kumar, Shruti Vaidya, “REDUCTION OF HARMONICS IN POWER DISTRIBUTION SYSTEMS USING HYBRID ACTIVE FILTER” International Journal of Advance Engineering and Research Development Volume 4, Issue 5, May -2017. 8. Nurul Syafiqah and Binti Ahmad Supri, “STUDY OF CURRENT HARMONIC REDUCTION IN OFFICE BUILDING” June 2013. 9. Ahmad, A. (2007), “Mitigation of Triplen Harmonics in 3-phase 4-wire Electrical Distribution System” Accessed on 21st January, 2011 at 7:05 pm, Available at: http://www.maik. ru/full/lasphys/05/1/lasphys1_05 p205full.pdf, 8 pp. 10. Anon, (2005), “Performance of Harmonic Mitigation Alternatives”, Accessed on 18th March, 2011 at 6:30 pm, Available at: http://www.mtecorp.com/ mitigation.pdf, 5 pp. 11. Ashok, S. (2002), “Effect of Power System Harmonics on Power System Equipment and Loads”, Accessed on the 15th February, 2011 at 3:20 pm, Available at: http://www. nalanda.nitc.ac.in/nitcresources/ee/lectures/ Effect.pdf, 5 pp
Download now