International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
37
THEORETICAL ANALYSIS OF THE PERFORMANCE OF
DUAL PRESSURE CONDENSER IN A THERMAL POWER
PLANT
K.K.Anantha Kirthan* S. Sathurtha Mourian* P. Raj Clinton*
*Department of Mechanical Engineering (SW)
PSG College of Technology (Autonomous Institution)
Coimbatore – 641 004
ABSTRACT
The condenser is a large shell-and – tube type heat exchanger. This is positioned next to the
turbine in order to receive a large flow rate of low pressure steam. This steam in condenser goes
under a phase change from vapour to liquid water. In thermal power plants, the primary purpose of a
surface condenser is to condense the exhaust steam from a steam turbine to obtain
maximum efficiency, and also to convert the turbine exhaust steam into pure water (referred to as
steam condensate) so that it may be reused in the steam generator or boiler as boiler feed water. A
Dual -pressure condenser results in efficiency improvement because the average turbine back
pressure is less compared with that of a single-pressure condenser. The average exhaust pressure of
the LP turbines becomes lower than the single pressure condenser.
This paper presents the theoretical analysis that shows the significant of dual pressure
condenser application in thermal power plants for improved efficiency over the conventional single
pressure condensers. Condenser performance is discussed in detail and the analytical results are
given with respect to dual pressure operation of condensers.
In India, the subcritical and supercritical units of thermal power plants which were supplied
by Chinese have adopted with the dual pressure condenser technology. This report introduces the
theoretical approach to the above technique with a brief description.
Keywords: Thermal Power Plant, Condenser, Single Pressure and Dual Pressure Condenser, LMTD,
Steam Cycle LP Turbine Efficiency, Condenser Effectiveness
INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND
TECHNOLOGY (IJMET)
ISSN 0976 – 6340 (Print)
ISSN 0976 – 6359 (Online)
Volume 6, Issue 2, February (2015), pp. 37-46
© IAEME: www.iaeme.com/IJMET.asp
Journal Impact Factor (2015): 8.8293 (Calculated by GISI)
www.jifactor.com
IJMET
© I A E M E
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp.
NOTATIONS
݉ሶ C Mass flow rate of cooling water
ܶܿ Condensing or saturation temperature
specific heat
Q Heat transfer
U Overall heat transfer coefficient
ܶ‫1ݓ‬ Cooling water inlet temperature
ܶ‫2ݓ‬ Cooling water outlet temperature
high pressure condenser
ܶ‫3ݓ‬ Cooling water outlet temperature at high pressure condenser
TTD Terminal temperature difference
∆t Diff between cooling water inlet & outlet temperature
δt Difference between
ln Natural logarithm
Tm Log mean temperature difference
hfg Specific enthalpy of steam
1. INTRODUCTION
Condenser is a heat –exchanger apparatus and is vital for a thermal power plant because the
efficiency of the turbine is fully d
increased by enhancing the heat transfer rate of a condenser; this can be achieved by reducing the
turbine exhaust pressure. The condenser is positioned next to the turbine in order to receive
flow rate of low pressure steam. This steam in the condenser goes under a phase change from vapour
to liquid water. External cooling water is pumped through thousands of tubes in the condenser to
transport the heat of condensation of the steam away
condensate is at a low temperature and pressure. Removal of this condensate may be considered as
maintaining the low pressure in the condenser continuously. The phase change in turn depends on
the transfer of heat to the external cooling water. The rejection of heat to the surroundings by the
cooling water is essential to maintain the low pressure in the condenser.
the back pressure a little bit increases the work of the turbine, inc
reduces steam flow for a given output.
2. DUAL PRESSURE CONDENSER
Large power plant condensers are usually 'shell and tube' heat exchangers
fluids do not come in direct contact and the heat released by the c
through the walls of the tubes into the cooling water continuously circulating inside them. In a “Dual
pressure condenser” the two shells operate at different pressures. The bottom sides (hot well) of both
the condensers are connected.
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976
e), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
38
Mass flow rate of cooling water
Condensing or saturation temperature
Overall heat transfer coefficient
Cooling water inlet temperature at Low pressure condenser
Cooling water outlet temperature at Low pressure condenser and inlet to th
high pressure condenser
Cooling water outlet temperature at high pressure condenser
Terminal temperature difference
Diff between cooling water inlet & outlet temperature
between the steam saturation temp & cooling water o
mean temperature difference (LMTD)
Specific enthalpy of steam
exchanger apparatus and is vital for a thermal power plant because the
efficiency of the turbine is fully dependant on it. The thermal efficiency of a power plant can be
increased by enhancing the heat transfer rate of a condenser; this can be achieved by reducing the
turbine exhaust pressure. The condenser is positioned next to the turbine in order to receive
flow rate of low pressure steam. This steam in the condenser goes under a phase change from vapour
to liquid water. External cooling water is pumped through thousands of tubes in the condenser to
transport the heat of condensation of the steam away from the plant. Upon leaving the condenser, the
condensate is at a low temperature and pressure. Removal of this condensate may be considered as
maintaining the low pressure in the condenser continuously. The phase change in turn depends on
f heat to the external cooling water. The rejection of heat to the surroundings by the
cooling water is essential to maintain the low pressure in the condenser. In condenser, by lowering
the back pressure a little bit increases the work of the turbine, increases the plant efficiency, and
reduces steam flow for a given output.
DUAL PRESSURE CONDENSER
Large power plant condensers are usually 'shell and tube' heat exchangers
fluids do not come in direct contact and the heat released by the condensation of steam is transferred
through the walls of the tubes into the cooling water continuously circulating inside them. In a “Dual
pressure condenser” the two shells operate at different pressures. The bottom sides (hot well) of both
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
© IAEME
at Low pressure condenser and inlet to the
steam saturation temp & cooling water outlet temp
exchanger apparatus and is vital for a thermal power plant because the
ependant on it. The thermal efficiency of a power plant can be
increased by enhancing the heat transfer rate of a condenser; this can be achieved by reducing the
turbine exhaust pressure. The condenser is positioned next to the turbine in order to receive a large
flow rate of low pressure steam. This steam in the condenser goes under a phase change from vapour
to liquid water. External cooling water is pumped through thousands of tubes in the condenser to
from the plant. Upon leaving the condenser, the
condensate is at a low temperature and pressure. Removal of this condensate may be considered as
maintaining the low pressure in the condenser continuously. The phase change in turn depends on
f heat to the external cooling water. The rejection of heat to the surroundings by the
condenser, by lowering
reases the plant efficiency, and
Large power plant condensers are usually 'shell and tube' heat exchangers where the two
ondensation of steam is transferred
through the walls of the tubes into the cooling water continuously circulating inside them. In a “Dual
pressure condenser” the two shells operate at different pressures. The bottom sides (hot well) of both
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
39
Figure-1 Dual pressure condenser arrangement
For the convenience of cleaning and maintenance, cooling water flows through the tubes and
steam condenses outside the tubes. These condensers can be classified based on the cooling water
flow as single or multi pressure, depending on whether the cooling water flow path creates one or
more turbine back pressures and thereby increasing the turbine efficiency. Dual pressure condensing
system is incorporated with two condensers. These condensers have different internal pressure from
each other and are installed below the each low pressure turbines LPT-A & LPT-B as shown in the
figure-1.
SERIES TYPE COOLING WATER FLOW ARRANGEMENT
In case of a serial configuration, the total cooling water mass flow rate enters the low
pressure condenser and upon exiting enters the high pressure condenser as in figure-2. Structurally,
the unit can be thought of as two separate condenser shells, although the actual design is often a
single shell with a pressure tight partition separating the high pressure condensing region (A) from
the lower pressure region (B).
Figure-2 Cooling water flow arrangement – series type
While part of the steam is expanded to a lower pressure and temperature (TCB < TC), the
remainder is discharged at a somewhat higher temperature (TCA > TC). Different condenser pressures
are achieved (Figure-3).
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
40
Figure-3 Temperature profile of dual pressure condenser
Assuming equal mass flow rates for the cooling water in both configurations, the average
condenser pressure in the serial arrangement is lower. In general, the lower the condenser pressure
the higher the efficiency of the overall plant.
CHARACTERISTICS OF CONDENSER
• Double-shell: Steam side divided by a sealed partition plate into two parts, shell A and shell B,
respectively
• Cooling water in B is colder than A
• Pressure in B lower than A as well
• Average pressure is lower at same heat transfer area and cooling water flow, higher vacuum
and thermal economy
• Single-pass: once-through
ADVANTAGES OF DUAL PRESSURE CONDENSER
The Dual pressure condenser is configured such a way that to obtain the
• Temperature of the condensate can be increased considerably. Both the hot wells are
interconnected at bottom which is having different temperature due to difference in saturation
pressure.
• A Dual -pressure condenser results in efficiency improvement because the average turbine
back pressure is less compared with that of a single-pressure condenser (Which is determined
by the highest circulating water temperature). The average exhaust pressure of the LP turbines
becomes lower than the single pressure condenser. (PA + PB)/2 < PS
• The TTD can be made larger in dual pressure condenser thereby the cooling area can be
reduced.
• Cooling water flow is reduced because it flows once through both condensers consecutively in
series. As a result, cooling tower size can be reduced and also, the pumping cost can be
reduced.
CONDENSER OPERATING CHARACTERISTICS
• Relationship of condenser vacuum , steam load, cooling water inlet temperature, circulating
water flow rate and the TTD is called operating characteristics, or thermal characteristics of
condenser
• The corresponding variation curve is called curve of condenser operating characteristics
• Vacuum of condenser corresponds to condensing water temperature Tc. So the factor which
affects the condenser vacuum also affects Tc
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
41
FACTORS AFFECTING THE OPERATING CHARACTERISTICS
These following 3 factors affect the vacuum in condenser
Tw1 - cooling water inlet temperature
∆t- (Tw2 - Tw1) diff between cooling water inlet & outlet temperature
δt –temp diff between steam saturation temp & cooling water outlet temp
Cooling water inlet temp (Tw1)
• If cooling water temperature (Tw1) decreases, saturation temperature of condensing steam (Tc)
also decreases, then vacuum will increase
• If cooling water temperature (Tw1) increases, saturation temperature of condensing steam (Tc)
also increases, then vacuum will decrease
Cooling water Temp rise (∆t )
• If t1, δt and exhaust steam constant, ∆t inversely proportional to cooling water flow.
• So, water flow ↓, ∆t ↑, vacuum ↓;
• water flow ↑, ∆t ↓, vacuum ↑
Steam load & δt
• ∆t proportional to exhaust steam,
• So, exhaust↑, ∆t↑, vacuum↓; vice versa
• In case of t1 and ∆t are constant, δt↓, vacuum↑; δt ↑, vacuum ↓
3. ANALYSIS OF DESIGN & TEST PARAMETERS OF CONDENSER
The Surface condenser - double back pressure, divided water box - double shell & single pass
condenser is considered for this analysis.
Table-1 Design & test data’s
Description Unit Design Data Test Data
Unit load MW 600 602
Total active area of the condenser m2
32150 32150
Numbers of pass and shell 1/2 1/2
Net heat carried away under the condition of circulating water kJ/s 795300 718907*
Circulating water flow kg/hr 68400000 63390000
Cooling water inlet temp (Tw1) ℃ 32 34.4
Cooling water outlet temp (Tw3) ℃ 42 44.1
CW inlet / outlet pressure in the water chamber MPa 0.3 0.27/ 0.22
Cleanness factor 0.85 -
Condenser inlet steam temp ℃ 48
Steam flow at condenser inlet
(LP turbine outlet)
kg/hr 1146000 1146000
Design TTD of the condenser 6.69/6.51 8 /3.39*
Condenser pressure KPa 10.13 12.9
Condensate (Hot well) temp ℃ 45.6 47.1
* calculated values
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
42
DATA ANALYSIS
Heat flow is one of the most critical parameters required for condenser performance
monitoring. Two methods are available to calculate this value: the water side Q and steam side Q. In
theory both value should be identical if it is assumed that no heat energy is lost from the steam side
through radiation from the condenser shell.
Parameters furnished in the TEST data column in the above table are considered for this
analysis of condenser performance.
4. PERFORMANCE ANALYSIS OF DUAL PRESSURE CONDENSER
If cooling water is supplied to condenser in series flow arrangement, the performance of
condenser can be: Let as assume that basis construction of both the condensers are same.
Figure - 4 cooling water flow in dual pressure condenser
Performance of low pressure condenser
Water side parameters of Low Pressure Turbine (B) at rated load of 600 MW:
Tw1 =34.4
Tw2 = ?
mሶ C = 63,390 m3
/hr = 17,608 kg/Sec
Heat gained by cooling Water in Condenser-B
Cooling waterside ‘Q’ is calculated from the relationship:
QGain = mሶ C X Cp (Tw2 - Tw1) -------- (A)
Where
Tw1 is the inlet cooling water temperature ( )
Tw2 is the outlet cooling water temperature ( )
mሶ C is the cooling water flow rate (kg/sec)
Cp is the specific heat of water, which may be assumed to be 4.19 kJ/kg
= 17,608 X 4.19 X (Tw2 - 34.4)
= 73777 X (Tw2 - 34.4) kJ/sec ------- (1)
Steam side Parameters of Low Pressure Turbine (B) at rated load of 600 MW
Total steam flow (at 2 LP Turbines) = 1146 T/hr
(The steam flow has been taken as half of the total flow but in actual condition it may vary due to
dual pressure at condensers)
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
43
Steam inlet at LP turbine (B) =
ଵଵସ଺
ଶ
= 573 T/hr @ 48 = 159 kg/sec @ 48
Therefore Heat value of steam at condenser inlet 12.9 kPa @ 48
From steam table, hfg = 2387 kJ/kg
Qlost by steam = 159 X 2387 = 379533 kJ/Sec ------ (2)
Heat gained by cooling water = Heat lost by the steam
From Equation (1) and (2)
73777 X (Tw2 - 34.4) = 379533, Tw2 = 5.1 + 34.4 = 39.5
Cooling water temperature at outlet of low pressure condenser-B (Tw2) = 39.5
Performance of high pressure condenser
Cooling water inlet temperature at high pressure condenser is 40
Hence, heat gained by the cooling water at high pressure condenser
QGain = ݉ሶ CP (Tw3 - Tw2) = 17,608 x 4.19 x (44.1 – 39.5) = 73777 x (44.1 - 40) = 339374 kJ/sec
Details of enthalpy gained by cooling water in series flow configuration
Hence, heat lost by steam at condenser-A = 339374 kJ/Sec = 159 kg/sec
159 X hfg = Qlost, hfg = 339374 / 159 = 2134 kJ/kg
The saturation temperature can be fixed for specific enthalpy of evaporation - 2134 kJ/kg & 90%
dryness fraction, the saturated steam temperature would be – 54.5
Calculation of LMTD for series flow configuration
LMTD of LOW pressure condenser ( Tm) - B:
Tw1 is the inlet cooling water temperature ( ) = 32
Tw2 is the outlet cooling water temperature ( ) = 39.5
Let us assume that the inlet temperature of steam & the out let temperature of condensate below the
condenser are same (since the latent heat alone is removed in condenser). At 12.9 kPa pressure
Tm (LP condenser-B) =
ሺ்௖		ି	்௪ଵሻ	ି	ሺ்௖		ି	்௪ଶሻ	
௟௡
ሺ೅೎		ష	೅ೢభሻ
ሺ೅೎		ష	೅ೢమሻ
=
ሺସ଼		ି	ଷସ.ସሻ	ି	ሺସ଼		ି	ଷଽ.ହሻ	
୪୬
ሺరఴ		ష	యర.రሻ
ሺరఴ		ష	యవ.ఱሻ
= 10.85
LMTD of HIGH pressure condenser ( Tm)-A
Tw2 is the inlet cooling water temperature ( ) = 39.5
Tw3 is the outlet cooling water temperature ( ) = 44.1
Let us assume that the inlet temperature of steam & the out let temperature of condensate below the
condenser are same (since the latent heat alone is removed at condenser).
Tm (HP condenser-A) =
ሺ48		ି39.5ሻ	ି	ሺ48		ି	44.1ሻ	
ln
ሺ48		ష	39.5ሻ
ሺ48		ష	44.1ሻ
= 5.97
Average LMTD of series flow cooling water 10.85 & 5.97 = 8.41
Effectiveness of condenser in series flow
(For design value) =
ሺTw2		ି	Tw1ሻ
ሺTs		ି	Tw1ሻ
=
ሺ42		ି	32ሻ
ሺ45.6		ି	32ሻ
= 0.735
Effectiveness of condenser in series flow
(For Test data) =
ሺ44.1		ି	34.4ሻ
ሺ47.1		ି	34.4ሻ
= 0.764
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
44
5. RESULTS AND DISCUSSIONS
All the calculations during this analysis have been performed on the basis of available plant
data and first law of thermodynamics. The intention of this analysis is to observe the causes which
affect the performance of the condenser. Based on the following assumption, the above calculations
were carried out and the results are tabulated as below:
The quantity of steam inlet at condenser is same as the design value
The dryness fraction of the steam at condenser inlet is 90%
Table-2 Calculated data of dual pressure condenser
Condenser ‘B’ Condenser ‘A’
Heat lost by steam kJ/Sec 379533 339374
Saturation temperature of steam entering the
turbines
℃ 48 48
Cooling water inlet temperature ℃ 34.4 (Tw1) 40 (Tw2)
Cooling water out let temperature ℃ 40 44.1 (Tw3)
Cooling water temperature difference ℃ 5.6 4.1
TTD ℃ 8 3.9
Saturated steam temperature ℃ 48 54.5
Corresponding saturation pressure at kPa 12.9 14.05
LMTD ℃ 10.85 5.97
Average LMTD ℃ 8.41
Effectiveness in dual flow 0.764
From the table, the followings are inferred:
It could be seen that the heat gained by the cooling water at condenser – A is less than
condenser-B by 11%. – This is due to higher CW inlet temperature at condenser-A.
Different saturation temperature of the steam at condenser inlet confirms the dual pressure
operation of the condenser.
Cooling Water inlet temperature at condenser inlet is higher than the design value. Cooling
water temperature is changing with weather conditions in particular region, and cannot be
changed in order to achieve better condenser performance. However, the test ∆ (9.7ºC) is
almost equal to the design value (10ºC). This can be increased by means of supplying more
quantities of cooling water.
The cooling water supplied to the condenser for rated load is less than the design value. Due
to higher cooling water inlet temperature, the condenser pressure is high.
Due to large LMTD, rate of heat transfer is more in dual pressure condenser which will
increase the work output of turbine.
The analysis is show that TTD is higher than the design value. This rise in TTD is due to
increase in cooling water inlet temperature. The TTD can be made larger in dual pressure
condenser thereby the cooling area can be reduced.
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
45
Performance test confirmed that the effectiveness of the condenser equaled or surpassed the
design value.
6. CONCLUSION
The technological investigations and analysis of various important characters affecting the
dual pressure condenser performance and other related factors responsible for deviation from ideal
working of condensers have been discussed. Also, the analytical results of dual pressure condenser
are presented in detail. From the analysis, it can be concluded that the causes which effecting the
performance of condenser are:
Deviation due to cooling water inlet temperature
Deviation due to water flow rate and
Deviation due to condenser pressure
In general, the lower the condenser pressure the higher the turbine efficiency and hence, the
overall plant cycle efficiency is improved. This performance test confirmed that the effectiveness of
the condenser is equaled or surpassed the design value. However, the following measures are
suggested to achieve the design performance and to ensure the sustained performance.
Cooling water flow can be increased to increase the condenser heat transfer rate for the given
cooling water temperature.
The total efficiency of the power plant can be increased considerably by overcome above
deviations in the condenser.
ACKNOWLEDGMENT
The authors would like to express their profound gratitude and deep regards to Mr.R.
VENKATESH for his exemplary guidance, monitoring and constant encouragement throughout the
course of this thesis. The blessing, help and guidance given by beloved principal shall carry them a
long way in the journey of life on which they are about to embark.
REFERENCES
1. R.K. Kapooria, K.S. Kasana and S.Kumar, “Technological investigations and efficiency
analysis of a steam heat exchange condenser: conceptual design of a hybrid steam
condenser”, Journal of Energy in Southern Africa, Vol 19 No 3, 35-45, Aug.2008.
2. Zhang C., Souse A.C.M., Venart J., The Numerical and experimental study of a power plant
condenser, J.Heat Tran 115 (1993) 435 – 445.
3. Heat Exchange Institute, standards for steam surface condensers, 9th
edition, Heat Exchange
Institute, Inc., Ohio, USA, 1995
4. R.P.Roy, M.Ratisher, V.K.Gokhale, A computational model of a power plant steam
condenser, J. Energy Resour. Technol.123 (2001) 81 c 91
5. M.M. El-Wakil, Power plant technology, McGraw-Hill Book Company, New York
6. Obert, E.F: Concepts of Thermodynamics. McGraw-Hill Book Company, New York, 1960
7. Chakrabarti S., 2005, ‘A case study on availability losses in a condenser for a 210 MW
thermal power unit in India”. Journal of Energy & Environment, 5: 144-148.
8. Arman J. and Ghosal A.K., 2007, “ Performance analysis of finned tube and unbaffle shell
and tube heat exchangers”, International Journal of Thermal Sciences, 46: 1311 – 1317
9. “Process heat Transfer” by D.Q.Kern, Edn. 1965.
10. “Modern Power Station Practice” – British Electricity International – Volume –G:
International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print),
ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME
46
11. Manjinder Bajwa and Piyush Gulati, “Comparing The Thermal Power Plant Performance At
Various Output Loads by Energy Auditing (A Statistical Analyzing Tool)” International
Journal of Mechanical Engineering & Technology (IJMET), Volume 2, Issue 2, 2011, pp.
111 - 126, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359.
12. S. Paliwala, H.Chandra and A. Tripathi, “Investigation and Analysis of Air Pollution Emitted
From Thermal Power Plants: A Critical Review” International Journal of Mechanical
Engineering & Technology (IJMET), Volume 4, Issue 4, 2013, pp. 32 - 37, ISSN Print: 0976
– 6340, ISSN Online: 0976 – 6359.
13. Vivek singh, Dr. A.C. Tiwari, Rajiv Gandhi Proudyogiki Vishwavidyalya, “Performance
Analysis of Electrostatic Precipitator In Thermal Power Plant” International Journal of
Mechanical Engineering & Technology (IJMET), Volume 3, Issue 2, 2012, pp. 431 - 436,
ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359.
AUTHORS DETAILS
Name : ANANTHA KIRTHAN K K
Degree : Bachelor o f Engineering
Field : Mechanical Engineering (SW)
Institution : PSG College of Technology
City : Coimbatore
State : Tamilnadu
Country : India
Name : SATHURTHA MOURIAN S
Degree : Bachelor o f Engineering
Field : Mechanical Engineering (SW)
Institution : PSG College of Technology
City : Coimbatore
State : Tamilnadu
Country : India
Name : RAJ CLINTON P
Degree : Bachelor o f Engineering
Field : Mechanical Engineering (SW)
Institution : PSG College of Technology
City : Coimbatore
State : Tamilnadu
Country : India

More Related Content

What's hot

BAROMETRIC JET CONDENSER
BAROMETRIC JET CONDENSERBAROMETRIC JET CONDENSER
BAROMETRIC JET CONDENSERClaire Canoy
 
2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...
2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...
2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...Komandur Sunder Raj, P.E.
 
Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...
Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...
Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...pkpravin89
 
Condenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant EngineeringCondenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant EngineeringAjaypalsinh Barad
 
S3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) NoteS3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) Noteno suhaila
 
Theoretical analysis of the performance of dual pressure condenser in a therm...
Theoretical analysis of the performance of dual pressure condenser in a therm...Theoretical analysis of the performance of dual pressure condenser in a therm...
Theoretical analysis of the performance of dual pressure condenser in a therm...IAEME Publication
 
1 reboilers types
1 reboilers types1 reboilers types
1 reboilers typeslesvit
 
Chilled water piping basics
Chilled water piping basicsChilled water piping basics
Chilled water piping basicsAp Naseem
 
MET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systems
MET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systemsMET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systems
MET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systemsIbrahim AboKhalil
 
HRSG,S knowledge
HRSG,S knowledgeHRSG,S knowledge
HRSG,S knowledgeumar farooq
 
Steam Condenser types,function, tube test, condenser vacuum
Steam Condenser types,function, tube test, condenser vacuumSteam Condenser types,function, tube test, condenser vacuum
Steam Condenser types,function, tube test, condenser vacuumwaqarahmed445
 
PPT On Steam Condenser
PPT On Steam Condenser PPT On Steam Condenser
PPT On Steam Condenser LowellHarbert
 
Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02
Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02
Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02Anish Ansari
 
Cooling towers in thermal power plants
Cooling towers in thermal power plantsCooling towers in thermal power plants
Cooling towers in thermal power plantsManohar Tatwawadi
 
Heat recovery steam generator
Heat recovery steam generatorHeat recovery steam generator
Heat recovery steam generatorumar farooq
 

What's hot (20)

BAROMETRIC JET CONDENSER
BAROMETRIC JET CONDENSERBAROMETRIC JET CONDENSER
BAROMETRIC JET CONDENSER
 
Project ppt
Project pptProject ppt
Project ppt
 
2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...
2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...
2007 ASME Power Conference Troubleshooting Condenser Vacuum Issues At North O...
 
Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...
Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...
Chiller repair, condenser &amp; refrigerant loop test, pump alignment, videos...
 
Condenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant EngineeringCondenser and Cooling Tower Power Plant Engineering
Condenser and Cooling Tower Power Plant Engineering
 
Condenser and its types
Condenser and its types Condenser and its types
Condenser and its types
 
S3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) NoteS3 Lec 2 (Condenser) Note
S3 Lec 2 (Condenser) Note
 
Theoretical analysis of the performance of dual pressure condenser in a therm...
Theoretical analysis of the performance of dual pressure condenser in a therm...Theoretical analysis of the performance of dual pressure condenser in a therm...
Theoretical analysis of the performance of dual pressure condenser in a therm...
 
Steam condenser
Steam condenserSteam condenser
Steam condenser
 
CONDENSERS & COOLING TOWERS
CONDENSERS & COOLING TOWERSCONDENSERS & COOLING TOWERS
CONDENSERS & COOLING TOWERS
 
1 reboilers types
1 reboilers types1 reboilers types
1 reboilers types
 
Chilled water piping basics
Chilled water piping basicsChilled water piping basics
Chilled water piping basics
 
MET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systems
MET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systemsMET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systems
MET 401 Chapter 9 -_condenser_feedwater_and_circulating_water_systems
 
HRSG,S knowledge
HRSG,S knowledgeHRSG,S knowledge
HRSG,S knowledge
 
Steam Condenser types,function, tube test, condenser vacuum
Steam Condenser types,function, tube test, condenser vacuumSteam Condenser types,function, tube test, condenser vacuum
Steam Condenser types,function, tube test, condenser vacuum
 
PPT On Steam Condenser
PPT On Steam Condenser PPT On Steam Condenser
PPT On Steam Condenser
 
Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02
Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02
Lec 202-28condenser-29-20dis-202011-130727113717-phpapp02
 
Cooling towers in thermal power plants
Cooling towers in thermal power plantsCooling towers in thermal power plants
Cooling towers in thermal power plants
 
2 ch3
2 ch32 ch3
2 ch3
 
Heat recovery steam generator
Heat recovery steam generatorHeat recovery steam generator
Heat recovery steam generator
 

Viewers also liked

Condenser in Thermal Power Plant
Condenser in Thermal Power PlantCondenser in Thermal Power Plant
Condenser in Thermal Power PlantMihir Patel
 
Thermal Power Generation Report
Thermal Power Generation ReportThermal Power Generation Report
Thermal Power Generation ReportManish Kumar
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticPichai Chaibamrung
 
Selection and Design of Condensers
Selection and Design of CondensersSelection and Design of Condensers
Selection and Design of CondensersGerard B. Hawkins
 

Viewers also liked (6)

Condenser in Thermal Power Plant
Condenser in Thermal Power PlantCondenser in Thermal Power Plant
Condenser in Thermal Power Plant
 
Thermal Power Generation Report
Thermal Power Generation ReportThermal Power Generation Report
Thermal Power Generation Report
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnostic
 
Selection and Design of Condensers
Selection and Design of CondensersSelection and Design of Condensers
Selection and Design of Condensers
 
Steam Condensers
Steam CondensersSteam Condensers
Steam Condensers
 
Design of condenser
Design of condenserDesign of condenser
Design of condenser
 

Similar to Theoretical analysis of the performance of dual pressure condenser in a thermal power plant

A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...
A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...
A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...Saikat Halder
 
01 regenerative feed heating
01 regenerative feed heating01 regenerative feed heating
01 regenerative feed heatingAnil Palamwar
 
Improving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller UnitsImproving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller UnitsDr. Amarjeet Singh
 
INTEGRATION OF WATER CHILLER AND AIR COOLER
INTEGRATION OF WATER CHILLER AND AIR COOLERINTEGRATION OF WATER CHILLER AND AIR COOLER
INTEGRATION OF WATER CHILLER AND AIR COOLERIRJET Journal
 
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...IJMREMJournal
 
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...IJMREMJournal
 
Cooling of mine air by chilled water system (final)
Cooling of mine air by chilled water system (final)Cooling of mine air by chilled water system (final)
Cooling of mine air by chilled water system (final)Safdar Ali
 
WATER CIRCUIT.pptx
WATER CIRCUIT.pptxWATER CIRCUIT.pptx
WATER CIRCUIT.pptxjimmyvale1
 
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...IRJET Journal
 
INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT
  INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT  INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT
INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANTIAEME Publication
 
Waste Heat Recovery From Refrigeration Plant
Waste Heat Recovery From Refrigeration PlantWaste Heat Recovery From Refrigeration Plant
Waste Heat Recovery From Refrigeration PlantIRJET Journal
 
Combined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser SystemsCombined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser SystemsIRJET Journal
 
Experimental investigation of waste heat recovery system for domestic refrige...
Experimental investigation of waste heat recovery system for domestic refrige...Experimental investigation of waste heat recovery system for domestic refrige...
Experimental investigation of waste heat recovery system for domestic refrige...IAEME Publication
 

Similar to Theoretical analysis of the performance of dual pressure condenser in a thermal power plant (20)

Bq34416421
Bq34416421Bq34416421
Bq34416421
 
D013161520
D013161520D013161520
D013161520
 
A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...
A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...
A STUDY ON ROLE OF CONDENSER AND NATURAL DRAFT COOLING TOWER ON THE PERFORMAN...
 
training report
training reporttraining report
training report
 
Ae04602212216
Ae04602212216Ae04602212216
Ae04602212216
 
01 regenerative feed heating
01 regenerative feed heating01 regenerative feed heating
01 regenerative feed heating
 
Improving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller UnitsImproving Efficiency of Cooling Coil Chiller Units
Improving Efficiency of Cooling Coil Chiller Units
 
INTEGRATION OF WATER CHILLER AND AIR COOLER
INTEGRATION OF WATER CHILLER AND AIR COOLERINTEGRATION OF WATER CHILLER AND AIR COOLER
INTEGRATION OF WATER CHILLER AND AIR COOLER
 
STEAM CONDENSERS ppt 2
STEAM CONDENSERS ppt 2STEAM CONDENSERS ppt 2
STEAM CONDENSERS ppt 2
 
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
 
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
Thermodynamic Analysis of Cooling Tower with Air to Air Heat Exchanger for Re...
 
STEAM CONDENSER
STEAM CONDENSERSTEAM CONDENSER
STEAM CONDENSER
 
Cooling of mine air by chilled water system (final)
Cooling of mine air by chilled water system (final)Cooling of mine air by chilled water system (final)
Cooling of mine air by chilled water system (final)
 
WATER CIRCUIT.pptx
WATER CIRCUIT.pptxWATER CIRCUIT.pptx
WATER CIRCUIT.pptx
 
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...IRJET-  	  Optimization of Flat Plate Solar Collector with Novel Heat Collect...
IRJET- Optimization of Flat Plate Solar Collector with Novel Heat Collect...
 
Cooling towers tech article v1r04
Cooling towers tech article v1r04Cooling towers tech article v1r04
Cooling towers tech article v1r04
 
INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT
  INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT  INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT
INDUSTRIAL WASTE HEAT USED IN TYPICAL THERMAL POWER PLANT
 
Waste Heat Recovery From Refrigeration Plant
Waste Heat Recovery From Refrigeration PlantWaste Heat Recovery From Refrigeration Plant
Waste Heat Recovery From Refrigeration Plant
 
Combined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser SystemsCombined Air Refrigeration, Air Conditioning and Water Dispenser Systems
Combined Air Refrigeration, Air Conditioning and Water Dispenser Systems
 
Experimental investigation of waste heat recovery system for domestic refrige...
Experimental investigation of waste heat recovery system for domestic refrige...Experimental investigation of waste heat recovery system for domestic refrige...
Experimental investigation of waste heat recovery system for domestic refrige...
 

More from IAEME Publication

IAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdfIAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdfIAEME Publication
 
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...IAEME Publication
 
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURSA STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURSIAEME Publication
 
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURSBROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURSIAEME Publication
 
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONSDETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONSIAEME Publication
 
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONSANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONSIAEME Publication
 
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINOVOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINOIAEME Publication
 
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...IAEME Publication
 
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMYVISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMYIAEME Publication
 
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...IAEME Publication
 
GANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICEGANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICEIAEME Publication
 
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...IAEME Publication
 
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...IAEME Publication
 
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...IAEME Publication
 
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...IAEME Publication
 
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...IAEME Publication
 
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...IAEME Publication
 
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...IAEME Publication
 
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...IAEME Publication
 
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENTA MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENTIAEME Publication
 

More from IAEME Publication (20)

IAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdfIAEME_Publication_Call_for_Paper_September_2022.pdf
IAEME_Publication_Call_for_Paper_September_2022.pdf
 
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
MODELING AND ANALYSIS OF SURFACE ROUGHNESS AND WHITE LATER THICKNESS IN WIRE-...
 
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURSA STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
A STUDY ON THE REASONS FOR TRANSGENDER TO BECOME ENTREPRENEURS
 
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURSBROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
BROAD UNEXPOSED SKILLS OF TRANSGENDER ENTREPRENEURS
 
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONSDETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
DETERMINANTS AFFECTING THE USER'S INTENTION TO USE MOBILE BANKING APPLICATIONS
 
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONSANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
ANALYSE THE USER PREDILECTION ON GPAY AND PHONEPE FOR DIGITAL TRANSACTIONS
 
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINOVOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
VOICE BASED ATM FOR VISUALLY IMPAIRED USING ARDUINO
 
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
IMPACT OF EMOTIONAL INTELLIGENCE ON HUMAN RESOURCE MANAGEMENT PRACTICES AMONG...
 
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMYVISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
VISUALISING AGING PARENTS & THEIR CLOSE CARERS LIFE JOURNEY IN AGING ECONOMY
 
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
A STUDY ON THE IMPACT OF ORGANIZATIONAL CULTURE ON THE EFFECTIVENESS OF PERFO...
 
GANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICEGANDHI ON NON-VIOLENT POLICE
GANDHI ON NON-VIOLENT POLICE
 
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
A STUDY ON TALENT MANAGEMENT AND ITS IMPACT ON EMPLOYEE RETENTION IN SELECTED...
 
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
ATTRITION IN THE IT INDUSTRY DURING COVID-19 PANDEMIC: LINKING EMOTIONAL INTE...
 
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
INFLUENCE OF TALENT MANAGEMENT PRACTICES ON ORGANIZATIONAL PERFORMANCE A STUD...
 
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
A STUDY OF VARIOUS TYPES OF LOANS OF SELECTED PUBLIC AND PRIVATE SECTOR BANKS...
 
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
EXPERIMENTAL STUDY OF MECHANICAL AND TRIBOLOGICAL RELATION OF NYLON/BaSO4 POL...
 
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
ROLE OF SOCIAL ENTREPRENEURSHIP IN RURAL DEVELOPMENT OF INDIA - PROBLEMS AND ...
 
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
OPTIMAL RECONFIGURATION OF POWER DISTRIBUTION RADIAL NETWORK USING HYBRID MET...
 
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
APPLICATION OF FRUGAL APPROACH FOR PRODUCTIVITY IMPROVEMENT - A CASE STUDY OF...
 
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENTA MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
A MULTIPLE – CHANNEL QUEUING MODELS ON FUZZY ENVIRONMENT
 

Recently uploaded

(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024Mark Billinghurst
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAbhinavSharma374939
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024hassan khalil
 
Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLDeelipZope
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxDeepakSakkari2
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).pptssuser5c9d4b1
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Serviceranjana rawat
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINESIVASHANKAR N
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxJoão Esperancinha
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...RajaP95
 
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...Call Girls in Nagpur High Profile
 

Recently uploaded (20)

(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(PRIYA) Rajgurunagar Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024IVE Industry Focused Event - Defence Sector 2024
IVE Industry Focused Event - Defence Sector 2024
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 
Analog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog ConverterAnalog to Digital and Digital to Analog Converter
Analog to Digital and Digital to Analog Converter
 
Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024Architect Hassan Khalil Portfolio for 2024
Architect Hassan Khalil Portfolio for 2024
 
Current Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCLCurrent Transformer Drawing and GTP for MSETCL
Current Transformer Drawing and GTP for MSETCL
 
Biology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptxBiology for Computer Engineers Course Handout.pptx
Biology for Computer Engineers Course Handout.pptx
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
247267395-1-Symmetric-and-distributed-shared-memory-architectures-ppt (1).ppt
 
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
(RIA) Call Girls Bhosari ( 7001035870 ) HI-Fi Pune Escorts Service
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINEMANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptxDecoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
IMPLICATIONS OF THE ABOVE HOLISTIC UNDERSTANDING OF HARMONY ON PROFESSIONAL E...
 
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
High Profile Call Girls Nashik Megha 7001305949 Independent Escort Service Na...
 

Theoretical analysis of the performance of dual pressure condenser in a thermal power plant

  • 1. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 37 THEORETICAL ANALYSIS OF THE PERFORMANCE OF DUAL PRESSURE CONDENSER IN A THERMAL POWER PLANT K.K.Anantha Kirthan* S. Sathurtha Mourian* P. Raj Clinton* *Department of Mechanical Engineering (SW) PSG College of Technology (Autonomous Institution) Coimbatore – 641 004 ABSTRACT The condenser is a large shell-and – tube type heat exchanger. This is positioned next to the turbine in order to receive a large flow rate of low pressure steam. This steam in condenser goes under a phase change from vapour to liquid water. In thermal power plants, the primary purpose of a surface condenser is to condense the exhaust steam from a steam turbine to obtain maximum efficiency, and also to convert the turbine exhaust steam into pure water (referred to as steam condensate) so that it may be reused in the steam generator or boiler as boiler feed water. A Dual -pressure condenser results in efficiency improvement because the average turbine back pressure is less compared with that of a single-pressure condenser. The average exhaust pressure of the LP turbines becomes lower than the single pressure condenser. This paper presents the theoretical analysis that shows the significant of dual pressure condenser application in thermal power plants for improved efficiency over the conventional single pressure condensers. Condenser performance is discussed in detail and the analytical results are given with respect to dual pressure operation of condensers. In India, the subcritical and supercritical units of thermal power plants which were supplied by Chinese have adopted with the dual pressure condenser technology. This report introduces the theoretical approach to the above technique with a brief description. Keywords: Thermal Power Plant, Condenser, Single Pressure and Dual Pressure Condenser, LMTD, Steam Cycle LP Turbine Efficiency, Condenser Effectiveness INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) ISSN 0976 – 6340 (Print) ISSN 0976 – 6359 (Online) Volume 6, Issue 2, February (2015), pp. 37-46 © IAEME: www.iaeme.com/IJMET.asp Journal Impact Factor (2015): 8.8293 (Calculated by GISI) www.jifactor.com IJMET © I A E M E
  • 2. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. NOTATIONS ݉ሶ C Mass flow rate of cooling water ܶܿ Condensing or saturation temperature specific heat Q Heat transfer U Overall heat transfer coefficient ܶ‫1ݓ‬ Cooling water inlet temperature ܶ‫2ݓ‬ Cooling water outlet temperature high pressure condenser ܶ‫3ݓ‬ Cooling water outlet temperature at high pressure condenser TTD Terminal temperature difference ∆t Diff between cooling water inlet & outlet temperature δt Difference between ln Natural logarithm Tm Log mean temperature difference hfg Specific enthalpy of steam 1. INTRODUCTION Condenser is a heat –exchanger apparatus and is vital for a thermal power plant because the efficiency of the turbine is fully d increased by enhancing the heat transfer rate of a condenser; this can be achieved by reducing the turbine exhaust pressure. The condenser is positioned next to the turbine in order to receive flow rate of low pressure steam. This steam in the condenser goes under a phase change from vapour to liquid water. External cooling water is pumped through thousands of tubes in the condenser to transport the heat of condensation of the steam away condensate is at a low temperature and pressure. Removal of this condensate may be considered as maintaining the low pressure in the condenser continuously. The phase change in turn depends on the transfer of heat to the external cooling water. The rejection of heat to the surroundings by the cooling water is essential to maintain the low pressure in the condenser. the back pressure a little bit increases the work of the turbine, inc reduces steam flow for a given output. 2. DUAL PRESSURE CONDENSER Large power plant condensers are usually 'shell and tube' heat exchangers fluids do not come in direct contact and the heat released by the c through the walls of the tubes into the cooling water continuously circulating inside them. In a “Dual pressure condenser” the two shells operate at different pressures. The bottom sides (hot well) of both the condensers are connected. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 e), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 38 Mass flow rate of cooling water Condensing or saturation temperature Overall heat transfer coefficient Cooling water inlet temperature at Low pressure condenser Cooling water outlet temperature at Low pressure condenser and inlet to th high pressure condenser Cooling water outlet temperature at high pressure condenser Terminal temperature difference Diff between cooling water inlet & outlet temperature between the steam saturation temp & cooling water o mean temperature difference (LMTD) Specific enthalpy of steam exchanger apparatus and is vital for a thermal power plant because the efficiency of the turbine is fully dependant on it. The thermal efficiency of a power plant can be increased by enhancing the heat transfer rate of a condenser; this can be achieved by reducing the turbine exhaust pressure. The condenser is positioned next to the turbine in order to receive flow rate of low pressure steam. This steam in the condenser goes under a phase change from vapour to liquid water. External cooling water is pumped through thousands of tubes in the condenser to transport the heat of condensation of the steam away from the plant. Upon leaving the condenser, the condensate is at a low temperature and pressure. Removal of this condensate may be considered as maintaining the low pressure in the condenser continuously. The phase change in turn depends on f heat to the external cooling water. The rejection of heat to the surroundings by the cooling water is essential to maintain the low pressure in the condenser. In condenser, by lowering the back pressure a little bit increases the work of the turbine, increases the plant efficiency, and reduces steam flow for a given output. DUAL PRESSURE CONDENSER Large power plant condensers are usually 'shell and tube' heat exchangers fluids do not come in direct contact and the heat released by the condensation of steam is transferred through the walls of the tubes into the cooling water continuously circulating inside them. In a “Dual pressure condenser” the two shells operate at different pressures. The bottom sides (hot well) of both International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), © IAEME at Low pressure condenser and inlet to the steam saturation temp & cooling water outlet temp exchanger apparatus and is vital for a thermal power plant because the ependant on it. The thermal efficiency of a power plant can be increased by enhancing the heat transfer rate of a condenser; this can be achieved by reducing the turbine exhaust pressure. The condenser is positioned next to the turbine in order to receive a large flow rate of low pressure steam. This steam in the condenser goes under a phase change from vapour to liquid water. External cooling water is pumped through thousands of tubes in the condenser to from the plant. Upon leaving the condenser, the condensate is at a low temperature and pressure. Removal of this condensate may be considered as maintaining the low pressure in the condenser continuously. The phase change in turn depends on f heat to the external cooling water. The rejection of heat to the surroundings by the condenser, by lowering reases the plant efficiency, and Large power plant condensers are usually 'shell and tube' heat exchangers where the two ondensation of steam is transferred through the walls of the tubes into the cooling water continuously circulating inside them. In a “Dual pressure condenser” the two shells operate at different pressures. The bottom sides (hot well) of both
  • 3. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 39 Figure-1 Dual pressure condenser arrangement For the convenience of cleaning and maintenance, cooling water flows through the tubes and steam condenses outside the tubes. These condensers can be classified based on the cooling water flow as single or multi pressure, depending on whether the cooling water flow path creates one or more turbine back pressures and thereby increasing the turbine efficiency. Dual pressure condensing system is incorporated with two condensers. These condensers have different internal pressure from each other and are installed below the each low pressure turbines LPT-A & LPT-B as shown in the figure-1. SERIES TYPE COOLING WATER FLOW ARRANGEMENT In case of a serial configuration, the total cooling water mass flow rate enters the low pressure condenser and upon exiting enters the high pressure condenser as in figure-2. Structurally, the unit can be thought of as two separate condenser shells, although the actual design is often a single shell with a pressure tight partition separating the high pressure condensing region (A) from the lower pressure region (B). Figure-2 Cooling water flow arrangement – series type While part of the steam is expanded to a lower pressure and temperature (TCB < TC), the remainder is discharged at a somewhat higher temperature (TCA > TC). Different condenser pressures are achieved (Figure-3).
  • 4. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 40 Figure-3 Temperature profile of dual pressure condenser Assuming equal mass flow rates for the cooling water in both configurations, the average condenser pressure in the serial arrangement is lower. In general, the lower the condenser pressure the higher the efficiency of the overall plant. CHARACTERISTICS OF CONDENSER • Double-shell: Steam side divided by a sealed partition plate into two parts, shell A and shell B, respectively • Cooling water in B is colder than A • Pressure in B lower than A as well • Average pressure is lower at same heat transfer area and cooling water flow, higher vacuum and thermal economy • Single-pass: once-through ADVANTAGES OF DUAL PRESSURE CONDENSER The Dual pressure condenser is configured such a way that to obtain the • Temperature of the condensate can be increased considerably. Both the hot wells are interconnected at bottom which is having different temperature due to difference in saturation pressure. • A Dual -pressure condenser results in efficiency improvement because the average turbine back pressure is less compared with that of a single-pressure condenser (Which is determined by the highest circulating water temperature). The average exhaust pressure of the LP turbines becomes lower than the single pressure condenser. (PA + PB)/2 < PS • The TTD can be made larger in dual pressure condenser thereby the cooling area can be reduced. • Cooling water flow is reduced because it flows once through both condensers consecutively in series. As a result, cooling tower size can be reduced and also, the pumping cost can be reduced. CONDENSER OPERATING CHARACTERISTICS • Relationship of condenser vacuum , steam load, cooling water inlet temperature, circulating water flow rate and the TTD is called operating characteristics, or thermal characteristics of condenser • The corresponding variation curve is called curve of condenser operating characteristics • Vacuum of condenser corresponds to condensing water temperature Tc. So the factor which affects the condenser vacuum also affects Tc
  • 5. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 41 FACTORS AFFECTING THE OPERATING CHARACTERISTICS These following 3 factors affect the vacuum in condenser Tw1 - cooling water inlet temperature ∆t- (Tw2 - Tw1) diff between cooling water inlet & outlet temperature δt –temp diff between steam saturation temp & cooling water outlet temp Cooling water inlet temp (Tw1) • If cooling water temperature (Tw1) decreases, saturation temperature of condensing steam (Tc) also decreases, then vacuum will increase • If cooling water temperature (Tw1) increases, saturation temperature of condensing steam (Tc) also increases, then vacuum will decrease Cooling water Temp rise (∆t ) • If t1, δt and exhaust steam constant, ∆t inversely proportional to cooling water flow. • So, water flow ↓, ∆t ↑, vacuum ↓; • water flow ↑, ∆t ↓, vacuum ↑ Steam load & δt • ∆t proportional to exhaust steam, • So, exhaust↑, ∆t↑, vacuum↓; vice versa • In case of t1 and ∆t are constant, δt↓, vacuum↑; δt ↑, vacuum ↓ 3. ANALYSIS OF DESIGN & TEST PARAMETERS OF CONDENSER The Surface condenser - double back pressure, divided water box - double shell & single pass condenser is considered for this analysis. Table-1 Design & test data’s Description Unit Design Data Test Data Unit load MW 600 602 Total active area of the condenser m2 32150 32150 Numbers of pass and shell 1/2 1/2 Net heat carried away under the condition of circulating water kJ/s 795300 718907* Circulating water flow kg/hr 68400000 63390000 Cooling water inlet temp (Tw1) ℃ 32 34.4 Cooling water outlet temp (Tw3) ℃ 42 44.1 CW inlet / outlet pressure in the water chamber MPa 0.3 0.27/ 0.22 Cleanness factor 0.85 - Condenser inlet steam temp ℃ 48 Steam flow at condenser inlet (LP turbine outlet) kg/hr 1146000 1146000 Design TTD of the condenser 6.69/6.51 8 /3.39* Condenser pressure KPa 10.13 12.9 Condensate (Hot well) temp ℃ 45.6 47.1 * calculated values
  • 6. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 42 DATA ANALYSIS Heat flow is one of the most critical parameters required for condenser performance monitoring. Two methods are available to calculate this value: the water side Q and steam side Q. In theory both value should be identical if it is assumed that no heat energy is lost from the steam side through radiation from the condenser shell. Parameters furnished in the TEST data column in the above table are considered for this analysis of condenser performance. 4. PERFORMANCE ANALYSIS OF DUAL PRESSURE CONDENSER If cooling water is supplied to condenser in series flow arrangement, the performance of condenser can be: Let as assume that basis construction of both the condensers are same. Figure - 4 cooling water flow in dual pressure condenser Performance of low pressure condenser Water side parameters of Low Pressure Turbine (B) at rated load of 600 MW: Tw1 =34.4 Tw2 = ? mሶ C = 63,390 m3 /hr = 17,608 kg/Sec Heat gained by cooling Water in Condenser-B Cooling waterside ‘Q’ is calculated from the relationship: QGain = mሶ C X Cp (Tw2 - Tw1) -------- (A) Where Tw1 is the inlet cooling water temperature ( ) Tw2 is the outlet cooling water temperature ( ) mሶ C is the cooling water flow rate (kg/sec) Cp is the specific heat of water, which may be assumed to be 4.19 kJ/kg = 17,608 X 4.19 X (Tw2 - 34.4) = 73777 X (Tw2 - 34.4) kJ/sec ------- (1) Steam side Parameters of Low Pressure Turbine (B) at rated load of 600 MW Total steam flow (at 2 LP Turbines) = 1146 T/hr (The steam flow has been taken as half of the total flow but in actual condition it may vary due to dual pressure at condensers)
  • 7. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 43 Steam inlet at LP turbine (B) = ଵଵସ଺ ଶ = 573 T/hr @ 48 = 159 kg/sec @ 48 Therefore Heat value of steam at condenser inlet 12.9 kPa @ 48 From steam table, hfg = 2387 kJ/kg Qlost by steam = 159 X 2387 = 379533 kJ/Sec ------ (2) Heat gained by cooling water = Heat lost by the steam From Equation (1) and (2) 73777 X (Tw2 - 34.4) = 379533, Tw2 = 5.1 + 34.4 = 39.5 Cooling water temperature at outlet of low pressure condenser-B (Tw2) = 39.5 Performance of high pressure condenser Cooling water inlet temperature at high pressure condenser is 40 Hence, heat gained by the cooling water at high pressure condenser QGain = ݉ሶ CP (Tw3 - Tw2) = 17,608 x 4.19 x (44.1 – 39.5) = 73777 x (44.1 - 40) = 339374 kJ/sec Details of enthalpy gained by cooling water in series flow configuration Hence, heat lost by steam at condenser-A = 339374 kJ/Sec = 159 kg/sec 159 X hfg = Qlost, hfg = 339374 / 159 = 2134 kJ/kg The saturation temperature can be fixed for specific enthalpy of evaporation - 2134 kJ/kg & 90% dryness fraction, the saturated steam temperature would be – 54.5 Calculation of LMTD for series flow configuration LMTD of LOW pressure condenser ( Tm) - B: Tw1 is the inlet cooling water temperature ( ) = 32 Tw2 is the outlet cooling water temperature ( ) = 39.5 Let us assume that the inlet temperature of steam & the out let temperature of condensate below the condenser are same (since the latent heat alone is removed in condenser). At 12.9 kPa pressure Tm (LP condenser-B) = ሺ்௖ ି ்௪ଵሻ ି ሺ்௖ ି ்௪ଶሻ ௟௡ ሺ೅೎ ష ೅ೢభሻ ሺ೅೎ ష ೅ೢమሻ = ሺସ଼ ି ଷସ.ସሻ ି ሺସ଼ ି ଷଽ.ହሻ ୪୬ ሺరఴ ష యర.రሻ ሺరఴ ష యవ.ఱሻ = 10.85 LMTD of HIGH pressure condenser ( Tm)-A Tw2 is the inlet cooling water temperature ( ) = 39.5 Tw3 is the outlet cooling water temperature ( ) = 44.1 Let us assume that the inlet temperature of steam & the out let temperature of condensate below the condenser are same (since the latent heat alone is removed at condenser). Tm (HP condenser-A) = ሺ48 ି39.5ሻ ି ሺ48 ି 44.1ሻ ln ሺ48 ష 39.5ሻ ሺ48 ష 44.1ሻ = 5.97 Average LMTD of series flow cooling water 10.85 & 5.97 = 8.41 Effectiveness of condenser in series flow (For design value) = ሺTw2 ି Tw1ሻ ሺTs ି Tw1ሻ = ሺ42 ି 32ሻ ሺ45.6 ି 32ሻ = 0.735 Effectiveness of condenser in series flow (For Test data) = ሺ44.1 ି 34.4ሻ ሺ47.1 ି 34.4ሻ = 0.764
  • 8. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 44 5. RESULTS AND DISCUSSIONS All the calculations during this analysis have been performed on the basis of available plant data and first law of thermodynamics. The intention of this analysis is to observe the causes which affect the performance of the condenser. Based on the following assumption, the above calculations were carried out and the results are tabulated as below: The quantity of steam inlet at condenser is same as the design value The dryness fraction of the steam at condenser inlet is 90% Table-2 Calculated data of dual pressure condenser Condenser ‘B’ Condenser ‘A’ Heat lost by steam kJ/Sec 379533 339374 Saturation temperature of steam entering the turbines ℃ 48 48 Cooling water inlet temperature ℃ 34.4 (Tw1) 40 (Tw2) Cooling water out let temperature ℃ 40 44.1 (Tw3) Cooling water temperature difference ℃ 5.6 4.1 TTD ℃ 8 3.9 Saturated steam temperature ℃ 48 54.5 Corresponding saturation pressure at kPa 12.9 14.05 LMTD ℃ 10.85 5.97 Average LMTD ℃ 8.41 Effectiveness in dual flow 0.764 From the table, the followings are inferred: It could be seen that the heat gained by the cooling water at condenser – A is less than condenser-B by 11%. – This is due to higher CW inlet temperature at condenser-A. Different saturation temperature of the steam at condenser inlet confirms the dual pressure operation of the condenser. Cooling Water inlet temperature at condenser inlet is higher than the design value. Cooling water temperature is changing with weather conditions in particular region, and cannot be changed in order to achieve better condenser performance. However, the test ∆ (9.7ºC) is almost equal to the design value (10ºC). This can be increased by means of supplying more quantities of cooling water. The cooling water supplied to the condenser for rated load is less than the design value. Due to higher cooling water inlet temperature, the condenser pressure is high. Due to large LMTD, rate of heat transfer is more in dual pressure condenser which will increase the work output of turbine. The analysis is show that TTD is higher than the design value. This rise in TTD is due to increase in cooling water inlet temperature. The TTD can be made larger in dual pressure condenser thereby the cooling area can be reduced.
  • 9. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 45 Performance test confirmed that the effectiveness of the condenser equaled or surpassed the design value. 6. CONCLUSION The technological investigations and analysis of various important characters affecting the dual pressure condenser performance and other related factors responsible for deviation from ideal working of condensers have been discussed. Also, the analytical results of dual pressure condenser are presented in detail. From the analysis, it can be concluded that the causes which effecting the performance of condenser are: Deviation due to cooling water inlet temperature Deviation due to water flow rate and Deviation due to condenser pressure In general, the lower the condenser pressure the higher the turbine efficiency and hence, the overall plant cycle efficiency is improved. This performance test confirmed that the effectiveness of the condenser is equaled or surpassed the design value. However, the following measures are suggested to achieve the design performance and to ensure the sustained performance. Cooling water flow can be increased to increase the condenser heat transfer rate for the given cooling water temperature. The total efficiency of the power plant can be increased considerably by overcome above deviations in the condenser. ACKNOWLEDGMENT The authors would like to express their profound gratitude and deep regards to Mr.R. VENKATESH for his exemplary guidance, monitoring and constant encouragement throughout the course of this thesis. The blessing, help and guidance given by beloved principal shall carry them a long way in the journey of life on which they are about to embark. REFERENCES 1. R.K. Kapooria, K.S. Kasana and S.Kumar, “Technological investigations and efficiency analysis of a steam heat exchange condenser: conceptual design of a hybrid steam condenser”, Journal of Energy in Southern Africa, Vol 19 No 3, 35-45, Aug.2008. 2. Zhang C., Souse A.C.M., Venart J., The Numerical and experimental study of a power plant condenser, J.Heat Tran 115 (1993) 435 – 445. 3. Heat Exchange Institute, standards for steam surface condensers, 9th edition, Heat Exchange Institute, Inc., Ohio, USA, 1995 4. R.P.Roy, M.Ratisher, V.K.Gokhale, A computational model of a power plant steam condenser, J. Energy Resour. Technol.123 (2001) 81 c 91 5. M.M. El-Wakil, Power plant technology, McGraw-Hill Book Company, New York 6. Obert, E.F: Concepts of Thermodynamics. McGraw-Hill Book Company, New York, 1960 7. Chakrabarti S., 2005, ‘A case study on availability losses in a condenser for a 210 MW thermal power unit in India”. Journal of Energy & Environment, 5: 144-148. 8. Arman J. and Ghosal A.K., 2007, “ Performance analysis of finned tube and unbaffle shell and tube heat exchangers”, International Journal of Thermal Sciences, 46: 1311 – 1317 9. “Process heat Transfer” by D.Q.Kern, Edn. 1965. 10. “Modern Power Station Practice” – British Electricity International – Volume –G:
  • 10. International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 – 6340(Print), ISSN 0976 – 6359(Online), Volume 6, Issue 2, February (2015), pp. 37-46© IAEME 46 11. Manjinder Bajwa and Piyush Gulati, “Comparing The Thermal Power Plant Performance At Various Output Loads by Energy Auditing (A Statistical Analyzing Tool)” International Journal of Mechanical Engineering & Technology (IJMET), Volume 2, Issue 2, 2011, pp. 111 - 126, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. 12. S. Paliwala, H.Chandra and A. Tripathi, “Investigation and Analysis of Air Pollution Emitted From Thermal Power Plants: A Critical Review” International Journal of Mechanical Engineering & Technology (IJMET), Volume 4, Issue 4, 2013, pp. 32 - 37, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. 13. Vivek singh, Dr. A.C. Tiwari, Rajiv Gandhi Proudyogiki Vishwavidyalya, “Performance Analysis of Electrostatic Precipitator In Thermal Power Plant” International Journal of Mechanical Engineering & Technology (IJMET), Volume 3, Issue 2, 2012, pp. 431 - 436, ISSN Print: 0976 – 6340, ISSN Online: 0976 – 6359. AUTHORS DETAILS Name : ANANTHA KIRTHAN K K Degree : Bachelor o f Engineering Field : Mechanical Engineering (SW) Institution : PSG College of Technology City : Coimbatore State : Tamilnadu Country : India Name : SATHURTHA MOURIAN S Degree : Bachelor o f Engineering Field : Mechanical Engineering (SW) Institution : PSG College of Technology City : Coimbatore State : Tamilnadu Country : India Name : RAJ CLINTON P Degree : Bachelor o f Engineering Field : Mechanical Engineering (SW) Institution : PSG College of Technology City : Coimbatore State : Tamilnadu Country : India