SlideShare a Scribd company logo
1 of 27
Download to read offline
REGULATIONS
CONCERNING APARTMENT DESIGN
Group 2
PAGE 1
CONTENTS
1. Classification of Residential Buildings
2. Parking requirements for Residential Buildings
3. Explanation of General Terms
4. Regulations for Group Developments
5. Regulations for Multi-Storeyed Buildings
6. Regulations for Ordinary Residential Buildings
7. Regulations for Special Buildings
8. Regulations for Layouts and Subdivisions
9. Case Studies
PAGE 2
What are development regulations?
To ensure planned development in the city, the Chennai Metropolitan
Development Authority (CMDA) prescribes a set of rules to be followed
whenever any building, public space or infrastructure is designed.
Why do we need to follow them?
 These rules are meant to control and prevent overcrowding on land.
 By following the rules standards of public health, convenience and safety are
met.
 As the planning authority has the power to punish the defaulters, misuse of
land is prevented in most cases.
Residential Buildings
Residential buildings are divided into four categories:
Ordinary Residential
Buildings
Group Developments
Special Residential
Buildings
Multi-story
Residential Buildings
PAGE 3
Ordinary Residential Buildings:
Buildings which have less than 300 sq. m
plot area and a maximum of G+1 structure in
height are classified as Ordinary Residential
buildings.
Special Residential Buildings:
A single residential building with more than 2
floors, more than 6 dwelling units is called a
special residential building.
Group Developments:
A development where the dwelling
units are in at least two or more blocks
and have minimum plot extent 300 sq.
m are called Group Developments.
Multi-storeyed Residential
Buildings
Any building that has more than 4
floors or 15.25 m height is a multi-
storeyed Building. These can also be
group developments.
PAGE 4
Parking Requirements
The parking requirement for all residential buildings, regardless of the site and type of
development, depends on the size of the dwelling unit.
(1) Corporation Limit, Municipalities, IT Corridor
For dwelling units with floor area up to 25 sq.m, no
parking space is required to be provided
For units with floor area above 25 sq.m and up to
50 sq.m, one two-wheeler space should be
provided.
For units with floor area above
50 sq.m and up to 75 sq.m, one
two-wheeler space should be
provided. Additionally, one car
space should be provided for
every two units.
One car space should be
provided for units with
floor area greater than 75
sq. m
PAGE 5
Additionally, parking spaces for visitors should be provided as 10% of the existing
parking spaces there are more than 3 car spaces.
(2) Panchayat Areas
The rules are the same for panchayat areas, only the floor area differs:
For dwelling units with floor area up to 50 sq.m,
no parking space is required to be provided
For units with floor area above 50 sq.m
and up to 75 sq.m, one two-wheeler space
should be provided.
For units with floor area above
75 sq.m and up to 100 sq.m, one
two-wheeler space should be
provided. Additionally, one car
space should be provided for
every two units.
One car space should be provided
for units with floor area greater
than 100 sq. m
PAGE 6
GENERAL TERMS
In order to understand the standards, we should have an understanding of the general
terms used in the upcoming topics:
 Setbacks
 Frontage
 Plot extent
 Plot coverage
 OSR
 FSI
Setbacks
In land use, a setback is the minimum
distance which a building or
other structure must be set back from a
street or road, a river or other stream, a
shore or flood plain, or any other place
which is needs protection. Usually,
standards are given for rear, front and side
setback.
Structures allowed in setback
(a) Ordinary Buildings (Non-multi-storeyed buildings)
 Sun-shades 0.60m
 Non-continuous wardrobes or built- in cub boards above 0.60m ground floor
 open non-continuous balconies (above ground floor)
 open service verandah to kitchen (above ground floor)
 Architectural projections above ground floor
 Staircase open landing projections (not affecting driveway)
 Cantilevered portico so long as it does not fall within 1.5m from the street
alignment or boundary of the site whichever is closer.
Balconies and staircase landings will be allowed only when they have at least a 0.5 m
clearance from the site boundary.
If the non- continuous projecting structures in the setbacks exceed 50% of the
side/length of the building, they won’t be allowed in the minimum prescribed setback
spaces.
Motor room of area not exceeding 2 sq.m. each and height not exceeding 1.8m,
without affecting parking and driveway requirements.
PAGE 1
Frontage
The side of the plot which faces the road.
a strip or extent of land abutting on a
street or water.
6 meters except in area set apart for
continuous buildings, where it shall not
be less than 4.5 meters and for housing,
economically weaker section it shall not
be less than 4 meters.
Minimum extent of plot
90 Square meters except in area specifically set apart for continuous buildings where
it shall not be less than 80 square meters. For housing economically weaker sections,
it shall not be less than 20 square meters within the Chennai City and 40 square
meters in rest of the Chennai Metropolitan Area.
Maximum plot coverage
Maximum plot coverage will be 65% and for Economically Weaker section plots, the
coverage shall not exceed 75 percent.
Passage Roads
Roads that provide access to a site from a main
road are called passage roads, and the site that
gains access from the passage road is called a
passage property.
PAGE 2
OSR – Open Space Reservation
As per current regulations, 10% of the total plot area should be reserved for open
space.
For plots with area 3000 sq.m to 10,000 sq.m, the owner/developer can either reserve
10% of the plot for OSR or get an exemption from OSR, if there is no provision to
reserve open space because of physical restrictions. To get exemption, the equivalent
land will be valued by the Registration Department and the market value should be
paid by the owner/developer. As per CMDA, the amount paid will be used for
environment related causes.
If the area of the layout is
greater than 10,000 sq.m, the
owner/developer must reserve
10% of the total plot as OSR.
This does not include the area
reserved for public roads.
The primary purpose of OSR is
to use the reserved area for
community or recreational
purposes such as residents’
association, park or play area by
the residents of the
development. CMDA has the
responsibility to ensure the maintenance of OSR. If CMDA is not satisfied with the
maintenance of OSR, it has the right to ask the owner of the land to transfer the land
to CMDA by gift deed. CMDA then hands over the site to local authority such as
Corporation of Chennai or Municipal authorities for maintenance.
FSI – Floor Space Index
FSI = Total floor space covered in all floors
Plot Area
The FSI for Ordinary Buildings is 1.5. This means, the total Plinth Area shall not exceed
1.5 times the Plot area in which the construction takes place.
PAGE 3
To arrive at the Floor
Area that could be
constructed, the
calculation must also
take into account the
following:
 Plot Coverage
 Set back space
 Abutting Road width
etc.
Premium FSI
Premium FSI is a tool to encourage vertical growth in a metropolis. In a city like
Chennai, where every inch of space counts Premium FSI is expected to ease the
pressure on land at least to a small extent by allowing construction of more floor area.
The premium FSI for plots abutting roads that have a width of
i. 30 feet or more and below 40 feet id 20%
ii. 40 feet to below 60 feet, the premium FSI is 30%
iii. 60 feet or more, it is 40%.
PAGE 4
REGULATIONS FOR GROUP DEVELOPMENTS
Group Developments:
Residential or Commercial developments
which have at least two or more blocks.
The blocks can be interconnected. But if
two blocks are solidly connected for more
than 1/3 of their width, they will be
considered as a single block.
Access Road:
1. Abutting road or access road
serving more than 20 dwellings or
more than 6000 square metres of
commercial building - minimum
width should be 10 m.
2. The width should be over 10 m
for at least 250 m distance from the
site to a junction.
3. If the general road is less than 10
m and the site owner leaves enough
space only in front of his site, it is not
acceptable.
4. If the site is not directly abutting a public road, but has a passage road from a
public road of 10 m width, the width of the passage should be:
PAGE 5
Description Width
1. When it serves up to 6 units and length is less than 80 metres 3.6 m
2. When it serves up to 8 units and length is less than 100 metres 4.8 m
3. When it serves up to 10 units and length is less than 120 metres 7.2 m
4. When it serves up to 20 units and length is less than 240 metres 9 m
5. When it serves more than 20 units 10 m
Rules for Upper Level Parking:
1. They should not be enclosed by walls, except for RCC parapet maximum height
1.2 m.
2. Should have adequate natural ventilation and lighting.
3. Water Closet or toilet facility and security cabin is allowed for each floor.
4. Minimum floor height should be 3 m.
Site Regulations:
PAGE 6
FSI for Economically Weaker Sections:
FSI = Total covered area on all floors/Plot area
If the unit is, 1. < 30 sq. m: the FSI = 1.5 times the normally permissible FSI
2. < 50 sq. m: the FSI = 1.3 times the normally permissible FSI
Electrical Room:
1. Electrical Room should be provided on the ground floor of the building within
the built-up space or within the premises.
2. Width of access road to should be at least 3 m.
Spacing 6m
3m (EWS)
Frontage
6m (CBA)
12m (CMA)
10 M (EWS)
PAGE 7
3. Electrical Room with RCC roof should have minimum 6x4 m floor area and 2.75
vertical clearance between electric wires and roof.
4. Room should be enclosed on three sides with wall and fourth side should have
M.S Rolling Grill Shutter. This side should face the approach road.
5. Electrical Room should have two exhaust fans, one on either side of the shutter.
6. It should have raised cement flooring with cable duct of width (450-750mm)
depth all around the inside of the room and close to the shutter. This should be
covered with RCC slabs minimum 75 mm width.
Sewage Treatment Plant:
1. If there are more than 50 units, sewage treatment plant should be provided and
maintained.
2. If there are less than 50 units, septic tank with up-flow filters should be
provided.
Basement Floor:
1. Height of the basement floor should not be more than 1.2 metres above ground
level
2. Headroom should be minimum 2.4 metres
3. Sufficient provision for lighting and ventilation should be made.
Other Regulations:
1. Security Cabin, water closet / pump room, transformer room, transformer yard,
electric room can be built in setback area, provided they do not block the
driveway and their height is less than 4 m.
2. These facilities can be built only if transformer and electrical rooms floor area
does not exceed 15 sq.m. and W.C and Pump room per block does not exceed 6
sq.m.
3. Corridor width within the building should be minimum 1 m.
4. If the building has more than 100 units, commercial units may be allowed in the
lower floor levels if they do not exceed 10% of that floor area.
5. If the building has more than 100 units, waste management system should be
provided with storage for solid waste near the access road where the local
authority can collect it.
6. Details of the development should be provided on a display board of minimum
size 60x120 cm.
7. Group development of units more than 50, or site area 10,000 sq. m (1 hectare)
should be designed and have plans signed by a qualified architect.
8. Group development of units more than 50, or site area 10,000 sq. m (1 hectare)
should reserve 10% of the site area to provide housing for lower income groups-
these units should have maximum 45 sq. m floor area.
PAGE 8
REGULATIONS FOR MULTI-STORIED
BUILDINGS
Additional regulations for multi-storeyed buildings area as follows:
Site Extent: Should be minimum 1500 sq. m
Road Width: Abutting road should be at least 18 m wide.
Internal Vehicular Access Road: Should have a minimum width of 7.2 m
PAGE 9
Recreational Space:
1. No requirement for site area less than 3000 sq. m
2. For site area above 3000 sq. m, 10% of the site area should be transferred to the
local authority, which may be allowed to be maintained as a public
park/playground.
Additional Facilities:
1. As per the NBC, lifts should be provided for each block.
2. Stand-by electric generator of adequate capacity for running lift and water
pump.
3. At least one metre room of size 2.4x2.4 m for every three floors.
4. Fire safety, detection and extinguishing systems.
Rainwater Conservation:
1. Pebble bed of 1 m width and 1.5 m depth all around the building with pebbles of
5 to 7.5 cm size.
2. Concrete paving around the building sloped in 1:20 ratio towards pebble bed for
surface runoff.
3. Dwarf walls height 7.5 cm constructed at entrance and exit gates to prevent
rainwater from the compound from draining onto the road.
4. Any of the given methods given in the DCR are to be adopted. For example,
PAGE 10
REGULATIONS FOR ORDINARY RESIDENTIAL
BUILDINGS
Plot extent: Maximum 300 sq.m
Maximum height: G+1 structure
PAGE 11
REGULATIONS FOR SPECIAL BUILDINGS
Building with more than 2 floors or more than 6 dwelling units.
Minimum Road Width:
 The minimum width of the public road on which the site abuts or gains
access shall be 10 mtrs.
 If the extent of the site is more than 1100 sq.m. a special building for
residential use may be permitted on a site abutting or gaining access from
9m. wide public road.
 In case it gains access from a passage road, the length of the passage should be
Description Width
1. When it serves up to 6 units and length is less than 80 metres 3.6 m
2. When it serves up to 8 units and length is less than 100 metres 4.8 m
3. When it serves up to 10 units and length is less than 120 metres 7.2 m
4. When it serves up to 20 units and length is less than 240 metres 9 m
5. When it serves more than 20 units 10 m
Regulations for special buildings are as follows:
PAGE 12
PAGE 13
REGULATIONS FOR LAYOUT AND SUBDIVISION
This regulation gives access to plots by roads and passageways, depending on the
intensity and length of the roads in that area.
PAGE 14
Additional Regulations:
 Ten per cent of layout area (excluding roads), additionally, shall be reserved for
"Public Purpose" in those layouts, which are more than 10000 sq.m. in extent.
Interested departments shall be given intimation of layout approval by the CMDA
and requested to purchase the land from the owner of developer of promoter, on
paying the cost of plots so reserved. The owner or developer or promoter has
every right to sell the lands for residential purpose if no demand from any public
departments is received within one year.
 In cases where the extent of the residential layout exceeds 10000 sq.m. ( 1
hectare) ten per cent of layout area (excluding roads) shall be developed as EWS
plots and the owner or developer or promoter shall sell these plot only for this
purpose. No conversion or amalgamation shall be permissible in these cases of
EWS plots
PAGE 15
CASE STUDIES
Case Study 1: Group Development
Kaveri Apartments,
Thiruvanmiyur
No. of blocks: 3
No. of units: 36
No. of units per block: 12
Spacing between blocks: 3.5 m
No. of parking spaces: 24
Frontage - 70.5m
Width - 48.5m
Road width - 10m
Plot area - 3419.25 sq.m
Plot coverage – 21.7%
FSI - 1.08
OSR - 705 sq.m
Height - G+2
SETBACKS
Front - 6m
Side - 3.5m
rear - 5m
Driveway width - 7.2m, 3.6m
Structure in Setback: Shed
PAGE 16
SECURITY CABIN MOTOR ROOM
UNUSED GARAGE
OSR
PAGE 17
Case Study 2: Special Building
Serene Apartments, Shanthi Colony
No. of blocks: 1
No. of units: 4
No. of units per floor: 1
No. of parking spaces: 8
Frontage - 16m
Width - 29.7m
Road width - 10m
Plot area - 475.2 sq.m
Plot coverage - 52.7%
FSI - 0.8
Height - stilt + 4
Driveway – 4m
No. of parking spaces: 8
SETBACKS:
Front-4m
Side-4m
Rear- 5m
PAGE 1
Case Study 3: Multi-storeyed Building
Pace Prana, Anna Nagar West
No. of blocks: 6
No. of units: 108
No. of units per block: 18
No. of parking spaces: 268
Frontage - 122m
Road width - 15.2m
Plot area - 12140.46 sq.m
Plot coverage - 28.37%
FSI - 1.75 + 0.551 = 2.261
OSR required-1214.046 sq.m
OSR provided- 1214.63 sq.m
Height - G+9
SETBACKS
Front - 7.3m
Side - 7m
rear - 7.6m
Driveway width - 3.5m
Spacing between blocks - 6.7m
No. of parking spaces : 268
PAGE 2
PAGE 3

More Related Content

What's hot

What's hot (20)

TYPES OF HOUSING AND RESIDINTIAL BLOCKS
TYPES OF HOUSING AND RESIDINTIAL BLOCKSTYPES OF HOUSING AND RESIDINTIAL BLOCKS
TYPES OF HOUSING AND RESIDINTIAL BLOCKS
 
Charles correa - housing projects
Charles correa - housing projectsCharles correa - housing projects
Charles correa - housing projects
 
HOUSING LITERATURE STUDY M.ARCH CCA
HOUSING LITERATURE STUDY M.ARCH CCAHOUSING LITERATURE STUDY M.ARCH CCA
HOUSING LITERATURE STUDY M.ARCH CCA
 
Case study on Mixed use building
Case study on Mixed use buildingCase study on Mixed use building
Case study on Mixed use building
 
Services in High Rise Building
Services in High Rise Building  Services in High Rise Building
Services in High Rise Building
 
Case Study: Sustainable Mixed-Use Development in Historic Urban Areas
Case Study: Sustainable Mixed-Use Development in Historic Urban AreasCase Study: Sustainable Mixed-Use Development in Historic Urban Areas
Case Study: Sustainable Mixed-Use Development in Historic Urban Areas
 
World one (Lodha Tower)
World one (Lodha Tower)World one (Lodha Tower)
World one (Lodha Tower)
 
Affordable Housing Design at Hathazari
Affordable Housing Design at HathazariAffordable Housing Design at Hathazari
Affordable Housing Design at Hathazari
 
Masters Thesis Report _ Skyscraper _ High rise Mixed use Development
Masters Thesis Report _ Skyscraper _ High rise Mixed use DevelopmentMasters Thesis Report _ Skyscraper _ High rise Mixed use Development
Masters Thesis Report _ Skyscraper _ High rise Mixed use Development
 
GATED COMMUNITY ARCHITECTURE THESIS CASE STUDY
GATED COMMUNITY ARCHITECTURE THESIS CASE STUDYGATED COMMUNITY ARCHITECTURE THESIS CASE STUDY
GATED COMMUNITY ARCHITECTURE THESIS CASE STUDY
 
Architecture design housing ppt
Architecture design housing pptArchitecture design housing ppt
Architecture design housing ppt
 
Mix use building case Study
Mix use building case Study Mix use building case Study
Mix use building case Study
 
Aranya Low Cost Housing
Aranya Low Cost HousingAranya Low Cost Housing
Aranya Low Cost Housing
 
Group Housing (Library Study)
Group Housing (Library Study)Group Housing (Library Study)
Group Housing (Library Study)
 
Architectural case study of Apartments
Architectural case study of ApartmentsArchitectural case study of Apartments
Architectural case study of Apartments
 
Time-Saver Standards for Architectural Design Data (Malestrom).pdf
Time-Saver Standards for Architectural Design Data (Malestrom).pdfTime-Saver Standards for Architectural Design Data (Malestrom).pdf
Time-Saver Standards for Architectural Design Data (Malestrom).pdf
 
Group housing case study
Group housing case studyGroup housing case study
Group housing case study
 
Group Housing Literature Study
Group Housing Literature StudyGroup Housing Literature Study
Group Housing Literature Study
 
High Rise Building Research Document
High Rise Building Research DocumentHigh Rise Building Research Document
High Rise Building Research Document
 
The interlace singapore
The interlace singaporeThe interlace singapore
The interlace singapore
 

Similar to Regulations (for apartments design)

Similar to Regulations (for apartments design) (20)

ppt7.pdf
ppt7.pdfppt7.pdf
ppt7.pdf
 
The goa land development and building 2010.
The goa land development and building 2010.The goa land development and building 2010.
The goa land development and building 2010.
 
Maharashtra Policies.pdf
Maharashtra Policies.pdfMaharashtra Policies.pdf
Maharashtra Policies.pdf
 
KPBR.pptx
KPBR.pptxKPBR.pptx
KPBR.pptx
 
PUNE BYE LAWS
PUNE BYE LAWSPUNE BYE LAWS
PUNE BYE LAWS
 
Haryana, Delhi, Noida, Chandigarh Building byelaws v
Haryana, Delhi, Noida, Chandigarh Building byelaws vHaryana, Delhi, Noida, Chandigarh Building byelaws v
Haryana, Delhi, Noida, Chandigarh Building byelaws v
 
Delhi bye
Delhi bye Delhi bye
Delhi bye
 
Building bye-laws-of-amritsar
Building bye-laws-of-amritsarBuilding bye-laws-of-amritsar
Building bye-laws-of-amritsar
 
building rules.pptx
building rules.pptxbuilding rules.pptx
building rules.pptx
 
GROUP 4 LITERATURE.pptx
GROUP 4 LITERATURE.pptxGROUP 4 LITERATURE.pptx
GROUP 4 LITERATURE.pptx
 
Building Bye Laws and Green Buildings
Building Bye Laws and Green BuildingsBuilding Bye Laws and Green Buildings
Building Bye Laws and Green Buildings
 
090727 Final HMU Options
090727  Final HMU Options090727  Final HMU Options
090727 Final HMU Options
 
Building Bye Laws for Residential Buildings
Building Bye Laws for Residential BuildingsBuilding Bye Laws for Residential Buildings
Building Bye Laws for Residential Buildings
 
Standards Requirement For Multiplexes And Bye Laws Of NOIDA
Standards Requirement For Multiplexes And Bye Laws Of NOIDAStandards Requirement For Multiplexes And Bye Laws Of NOIDA
Standards Requirement For Multiplexes And Bye Laws Of NOIDA
 
Parking guidelines.(drashti)
Parking guidelines.(drashti)Parking guidelines.(drashti)
Parking guidelines.(drashti)
 
Development Control Regulations, Mumbai - Key points
Development Control Regulations, Mumbai - Key pointsDevelopment Control Regulations, Mumbai - Key points
Development Control Regulations, Mumbai - Key points
 
Building bye laws
Building bye lawsBuilding bye laws
Building bye laws
 
General Development Control Regulations (GDCR).pptx
General Development Control Regulations (GDCR).pptxGeneral Development Control Regulations (GDCR).pptx
General Development Control Regulations (GDCR).pptx
 
DATA COLLECTION for university design.pdf
DATA COLLECTION for university design.pdfDATA COLLECTION for university design.pdf
DATA COLLECTION for university design.pdf
 
Housing Data collection.pdf
Housing Data collection.pdfHousing Data collection.pdf
Housing Data collection.pdf
 

Recently uploaded

一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样
一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样
一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样
yhavx
 
一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证
一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证
一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证
eqaqen
 
如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证
ugzga
 
Resume all my skills and educations and achievement
Resume all my skills and educations and  achievement Resume all my skills and educations and  achievement
Resume all my skills and educations and achievement
210303105569
 
定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制
定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制
定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制
eqaqen
 
一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证
一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证
一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证
wpkuukw
 
Design-System - FinTech - Isadora Agency
Design-System - FinTech - Isadora AgencyDesign-System - FinTech - Isadora Agency
Design-System - FinTech - Isadora Agency
Isadora Agency
 
Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
ZurliaSoop
 

Recently uploaded (20)

Morgenbooster: Storytelling in Identity Design
Morgenbooster: Storytelling in Identity DesignMorgenbooster: Storytelling in Identity Design
Morgenbooster: Storytelling in Identity Design
 
一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样
一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样
一比一原版(ANU毕业证书)澳大利亚国立大学毕业证原件一模一样
 
一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证
一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证
一比一定(购)西悉尼大学毕业证(WSU毕业证)成绩单学位证
 
Spring Summer 2026 Inspirations trend book Peclers Paris
Spring Summer 2026 Inspirations trend book Peclers ParisSpring Summer 2026 Inspirations trend book Peclers Paris
Spring Summer 2026 Inspirations trend book Peclers Paris
 
Furniture & Joinery Details_Designs.pptx
Furniture & Joinery Details_Designs.pptxFurniture & Joinery Details_Designs.pptx
Furniture & Joinery Details_Designs.pptx
 
Branding in the Psychedelic Landscape Report.pdf
Branding in the Psychedelic Landscape Report.pdfBranding in the Psychedelic Landscape Report.pdf
Branding in the Psychedelic Landscape Report.pdf
 
Essential UI/UX Design Principles: A Comprehensive Guide
Essential UI/UX Design Principles: A Comprehensive GuideEssential UI/UX Design Principles: A Comprehensive Guide
Essential UI/UX Design Principles: A Comprehensive Guide
 
如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证
如何办理(Columbia College毕业证书)纽约市哥伦比亚大学毕业证成绩单本科硕士学位证留信学历认证
 
Resume all my skills and educations and achievement
Resume all my skills and educations and  achievement Resume all my skills and educations and  achievement
Resume all my skills and educations and achievement
 
Edward Boginsky's Trailblazing Contributions to Printing
Edward Boginsky's Trailblazing Contributions to PrintingEdward Boginsky's Trailblazing Contributions to Printing
Edward Boginsky's Trailblazing Contributions to Printing
 
定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制
定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制
定(购)莫纳什大学毕业证(Monash毕业证)成绩单学位证专业定制
 
Abortion pills in Jeddah +966572737505 <> buy cytotec <> unwanted kit Saudi A...
Abortion pills in Jeddah +966572737505 <> buy cytotec <> unwanted kit Saudi A...Abortion pills in Jeddah +966572737505 <> buy cytotec <> unwanted kit Saudi A...
Abortion pills in Jeddah +966572737505 <> buy cytotec <> unwanted kit Saudi A...
 
一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证
一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证
一比一定(购)卡尔顿大学毕业证(CU毕业证)成绩单学位证
 
Design-System - FinTech - Isadora Agency
Design-System - FinTech - Isadora AgencyDesign-System - FinTech - Isadora Agency
Design-System - FinTech - Isadora Agency
 
Gamestore case study UI UX by Amgad Ibrahim
Gamestore case study UI UX by Amgad IbrahimGamestore case study UI UX by Amgad Ibrahim
Gamestore case study UI UX by Amgad Ibrahim
 
TRose UXPA Experience Design Concord .pptx
TRose UXPA Experience Design Concord .pptxTRose UXPA Experience Design Concord .pptx
TRose UXPA Experience Design Concord .pptx
 
18+ Young ℂall Girls Vadodara Book Esha 7427069034 Top Class ℂall Girl Serviℂ...
18+ Young ℂall Girls Vadodara Book Esha 7427069034 Top Class ℂall Girl Serviℂ...18+ Young ℂall Girls Vadodara Book Esha 7427069034 Top Class ℂall Girl Serviℂ...
18+ Young ℂall Girls Vadodara Book Esha 7427069034 Top Class ℂall Girl Serviℂ...
 
Abortion pills in Riyadh +966572737505 <> buy cytotec <> unwanted kit Saudi A...
Abortion pills in Riyadh +966572737505 <> buy cytotec <> unwanted kit Saudi A...Abortion pills in Riyadh +966572737505 <> buy cytotec <> unwanted kit Saudi A...
Abortion pills in Riyadh +966572737505 <> buy cytotec <> unwanted kit Saudi A...
 
Academic Portfolio (2017-2021) .pdf
Academic Portfolio (2017-2021)      .pdfAcademic Portfolio (2017-2021)      .pdf
Academic Portfolio (2017-2021) .pdf
 
Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
Jual Obat Aborsi Semarang ( Asli No.1 ) 085657271886 Obat Penggugur Kandungan...
 

Regulations (for apartments design)

  • 2. PAGE 1 CONTENTS 1. Classification of Residential Buildings 2. Parking requirements for Residential Buildings 3. Explanation of General Terms 4. Regulations for Group Developments 5. Regulations for Multi-Storeyed Buildings 6. Regulations for Ordinary Residential Buildings 7. Regulations for Special Buildings 8. Regulations for Layouts and Subdivisions 9. Case Studies
  • 3. PAGE 2 What are development regulations? To ensure planned development in the city, the Chennai Metropolitan Development Authority (CMDA) prescribes a set of rules to be followed whenever any building, public space or infrastructure is designed. Why do we need to follow them?  These rules are meant to control and prevent overcrowding on land.  By following the rules standards of public health, convenience and safety are met.  As the planning authority has the power to punish the defaulters, misuse of land is prevented in most cases. Residential Buildings Residential buildings are divided into four categories: Ordinary Residential Buildings Group Developments Special Residential Buildings Multi-story Residential Buildings
  • 4. PAGE 3 Ordinary Residential Buildings: Buildings which have less than 300 sq. m plot area and a maximum of G+1 structure in height are classified as Ordinary Residential buildings. Special Residential Buildings: A single residential building with more than 2 floors, more than 6 dwelling units is called a special residential building. Group Developments: A development where the dwelling units are in at least two or more blocks and have minimum plot extent 300 sq. m are called Group Developments. Multi-storeyed Residential Buildings Any building that has more than 4 floors or 15.25 m height is a multi- storeyed Building. These can also be group developments.
  • 5. PAGE 4 Parking Requirements The parking requirement for all residential buildings, regardless of the site and type of development, depends on the size of the dwelling unit. (1) Corporation Limit, Municipalities, IT Corridor For dwelling units with floor area up to 25 sq.m, no parking space is required to be provided For units with floor area above 25 sq.m and up to 50 sq.m, one two-wheeler space should be provided. For units with floor area above 50 sq.m and up to 75 sq.m, one two-wheeler space should be provided. Additionally, one car space should be provided for every two units. One car space should be provided for units with floor area greater than 75 sq. m
  • 6. PAGE 5 Additionally, parking spaces for visitors should be provided as 10% of the existing parking spaces there are more than 3 car spaces. (2) Panchayat Areas The rules are the same for panchayat areas, only the floor area differs: For dwelling units with floor area up to 50 sq.m, no parking space is required to be provided For units with floor area above 50 sq.m and up to 75 sq.m, one two-wheeler space should be provided. For units with floor area above 75 sq.m and up to 100 sq.m, one two-wheeler space should be provided. Additionally, one car space should be provided for every two units. One car space should be provided for units with floor area greater than 100 sq. m
  • 7. PAGE 6 GENERAL TERMS In order to understand the standards, we should have an understanding of the general terms used in the upcoming topics:  Setbacks  Frontage  Plot extent  Plot coverage  OSR  FSI Setbacks In land use, a setback is the minimum distance which a building or other structure must be set back from a street or road, a river or other stream, a shore or flood plain, or any other place which is needs protection. Usually, standards are given for rear, front and side setback. Structures allowed in setback (a) Ordinary Buildings (Non-multi-storeyed buildings)  Sun-shades 0.60m  Non-continuous wardrobes or built- in cub boards above 0.60m ground floor  open non-continuous balconies (above ground floor)  open service verandah to kitchen (above ground floor)  Architectural projections above ground floor  Staircase open landing projections (not affecting driveway)  Cantilevered portico so long as it does not fall within 1.5m from the street alignment or boundary of the site whichever is closer. Balconies and staircase landings will be allowed only when they have at least a 0.5 m clearance from the site boundary. If the non- continuous projecting structures in the setbacks exceed 50% of the side/length of the building, they won’t be allowed in the minimum prescribed setback spaces. Motor room of area not exceeding 2 sq.m. each and height not exceeding 1.8m, without affecting parking and driveway requirements.
  • 8. PAGE 1 Frontage The side of the plot which faces the road. a strip or extent of land abutting on a street or water. 6 meters except in area set apart for continuous buildings, where it shall not be less than 4.5 meters and for housing, economically weaker section it shall not be less than 4 meters. Minimum extent of plot 90 Square meters except in area specifically set apart for continuous buildings where it shall not be less than 80 square meters. For housing economically weaker sections, it shall not be less than 20 square meters within the Chennai City and 40 square meters in rest of the Chennai Metropolitan Area. Maximum plot coverage Maximum plot coverage will be 65% and for Economically Weaker section plots, the coverage shall not exceed 75 percent. Passage Roads Roads that provide access to a site from a main road are called passage roads, and the site that gains access from the passage road is called a passage property.
  • 9. PAGE 2 OSR – Open Space Reservation As per current regulations, 10% of the total plot area should be reserved for open space. For plots with area 3000 sq.m to 10,000 sq.m, the owner/developer can either reserve 10% of the plot for OSR or get an exemption from OSR, if there is no provision to reserve open space because of physical restrictions. To get exemption, the equivalent land will be valued by the Registration Department and the market value should be paid by the owner/developer. As per CMDA, the amount paid will be used for environment related causes. If the area of the layout is greater than 10,000 sq.m, the owner/developer must reserve 10% of the total plot as OSR. This does not include the area reserved for public roads. The primary purpose of OSR is to use the reserved area for community or recreational purposes such as residents’ association, park or play area by the residents of the development. CMDA has the responsibility to ensure the maintenance of OSR. If CMDA is not satisfied with the maintenance of OSR, it has the right to ask the owner of the land to transfer the land to CMDA by gift deed. CMDA then hands over the site to local authority such as Corporation of Chennai or Municipal authorities for maintenance. FSI – Floor Space Index FSI = Total floor space covered in all floors Plot Area The FSI for Ordinary Buildings is 1.5. This means, the total Plinth Area shall not exceed 1.5 times the Plot area in which the construction takes place.
  • 10. PAGE 3 To arrive at the Floor Area that could be constructed, the calculation must also take into account the following:  Plot Coverage  Set back space  Abutting Road width etc. Premium FSI Premium FSI is a tool to encourage vertical growth in a metropolis. In a city like Chennai, where every inch of space counts Premium FSI is expected to ease the pressure on land at least to a small extent by allowing construction of more floor area. The premium FSI for plots abutting roads that have a width of i. 30 feet or more and below 40 feet id 20% ii. 40 feet to below 60 feet, the premium FSI is 30% iii. 60 feet or more, it is 40%.
  • 11. PAGE 4 REGULATIONS FOR GROUP DEVELOPMENTS Group Developments: Residential or Commercial developments which have at least two or more blocks. The blocks can be interconnected. But if two blocks are solidly connected for more than 1/3 of their width, they will be considered as a single block. Access Road: 1. Abutting road or access road serving more than 20 dwellings or more than 6000 square metres of commercial building - minimum width should be 10 m. 2. The width should be over 10 m for at least 250 m distance from the site to a junction. 3. If the general road is less than 10 m and the site owner leaves enough space only in front of his site, it is not acceptable. 4. If the site is not directly abutting a public road, but has a passage road from a public road of 10 m width, the width of the passage should be:
  • 12. PAGE 5 Description Width 1. When it serves up to 6 units and length is less than 80 metres 3.6 m 2. When it serves up to 8 units and length is less than 100 metres 4.8 m 3. When it serves up to 10 units and length is less than 120 metres 7.2 m 4. When it serves up to 20 units and length is less than 240 metres 9 m 5. When it serves more than 20 units 10 m Rules for Upper Level Parking: 1. They should not be enclosed by walls, except for RCC parapet maximum height 1.2 m. 2. Should have adequate natural ventilation and lighting. 3. Water Closet or toilet facility and security cabin is allowed for each floor. 4. Minimum floor height should be 3 m. Site Regulations:
  • 13. PAGE 6 FSI for Economically Weaker Sections: FSI = Total covered area on all floors/Plot area If the unit is, 1. < 30 sq. m: the FSI = 1.5 times the normally permissible FSI 2. < 50 sq. m: the FSI = 1.3 times the normally permissible FSI Electrical Room: 1. Electrical Room should be provided on the ground floor of the building within the built-up space or within the premises. 2. Width of access road to should be at least 3 m. Spacing 6m 3m (EWS) Frontage 6m (CBA) 12m (CMA) 10 M (EWS)
  • 14. PAGE 7 3. Electrical Room with RCC roof should have minimum 6x4 m floor area and 2.75 vertical clearance between electric wires and roof. 4. Room should be enclosed on three sides with wall and fourth side should have M.S Rolling Grill Shutter. This side should face the approach road. 5. Electrical Room should have two exhaust fans, one on either side of the shutter. 6. It should have raised cement flooring with cable duct of width (450-750mm) depth all around the inside of the room and close to the shutter. This should be covered with RCC slabs minimum 75 mm width. Sewage Treatment Plant: 1. If there are more than 50 units, sewage treatment plant should be provided and maintained. 2. If there are less than 50 units, septic tank with up-flow filters should be provided. Basement Floor: 1. Height of the basement floor should not be more than 1.2 metres above ground level 2. Headroom should be minimum 2.4 metres 3. Sufficient provision for lighting and ventilation should be made. Other Regulations: 1. Security Cabin, water closet / pump room, transformer room, transformer yard, electric room can be built in setback area, provided they do not block the driveway and their height is less than 4 m. 2. These facilities can be built only if transformer and electrical rooms floor area does not exceed 15 sq.m. and W.C and Pump room per block does not exceed 6 sq.m. 3. Corridor width within the building should be minimum 1 m. 4. If the building has more than 100 units, commercial units may be allowed in the lower floor levels if they do not exceed 10% of that floor area. 5. If the building has more than 100 units, waste management system should be provided with storage for solid waste near the access road where the local authority can collect it. 6. Details of the development should be provided on a display board of minimum size 60x120 cm. 7. Group development of units more than 50, or site area 10,000 sq. m (1 hectare) should be designed and have plans signed by a qualified architect. 8. Group development of units more than 50, or site area 10,000 sq. m (1 hectare) should reserve 10% of the site area to provide housing for lower income groups- these units should have maximum 45 sq. m floor area.
  • 15. PAGE 8 REGULATIONS FOR MULTI-STORIED BUILDINGS Additional regulations for multi-storeyed buildings area as follows: Site Extent: Should be minimum 1500 sq. m Road Width: Abutting road should be at least 18 m wide. Internal Vehicular Access Road: Should have a minimum width of 7.2 m
  • 16. PAGE 9 Recreational Space: 1. No requirement for site area less than 3000 sq. m 2. For site area above 3000 sq. m, 10% of the site area should be transferred to the local authority, which may be allowed to be maintained as a public park/playground. Additional Facilities: 1. As per the NBC, lifts should be provided for each block. 2. Stand-by electric generator of adequate capacity for running lift and water pump. 3. At least one metre room of size 2.4x2.4 m for every three floors. 4. Fire safety, detection and extinguishing systems. Rainwater Conservation: 1. Pebble bed of 1 m width and 1.5 m depth all around the building with pebbles of 5 to 7.5 cm size. 2. Concrete paving around the building sloped in 1:20 ratio towards pebble bed for surface runoff. 3. Dwarf walls height 7.5 cm constructed at entrance and exit gates to prevent rainwater from the compound from draining onto the road. 4. Any of the given methods given in the DCR are to be adopted. For example,
  • 17. PAGE 10 REGULATIONS FOR ORDINARY RESIDENTIAL BUILDINGS Plot extent: Maximum 300 sq.m Maximum height: G+1 structure
  • 18. PAGE 11 REGULATIONS FOR SPECIAL BUILDINGS Building with more than 2 floors or more than 6 dwelling units. Minimum Road Width:  The minimum width of the public road on which the site abuts or gains access shall be 10 mtrs.  If the extent of the site is more than 1100 sq.m. a special building for residential use may be permitted on a site abutting or gaining access from 9m. wide public road.  In case it gains access from a passage road, the length of the passage should be Description Width 1. When it serves up to 6 units and length is less than 80 metres 3.6 m 2. When it serves up to 8 units and length is less than 100 metres 4.8 m 3. When it serves up to 10 units and length is less than 120 metres 7.2 m 4. When it serves up to 20 units and length is less than 240 metres 9 m 5. When it serves more than 20 units 10 m Regulations for special buildings are as follows:
  • 20. PAGE 13 REGULATIONS FOR LAYOUT AND SUBDIVISION This regulation gives access to plots by roads and passageways, depending on the intensity and length of the roads in that area.
  • 21. PAGE 14 Additional Regulations:  Ten per cent of layout area (excluding roads), additionally, shall be reserved for "Public Purpose" in those layouts, which are more than 10000 sq.m. in extent. Interested departments shall be given intimation of layout approval by the CMDA and requested to purchase the land from the owner of developer of promoter, on paying the cost of plots so reserved. The owner or developer or promoter has every right to sell the lands for residential purpose if no demand from any public departments is received within one year.  In cases where the extent of the residential layout exceeds 10000 sq.m. ( 1 hectare) ten per cent of layout area (excluding roads) shall be developed as EWS plots and the owner or developer or promoter shall sell these plot only for this purpose. No conversion or amalgamation shall be permissible in these cases of EWS plots
  • 22. PAGE 15 CASE STUDIES Case Study 1: Group Development Kaveri Apartments, Thiruvanmiyur No. of blocks: 3 No. of units: 36 No. of units per block: 12 Spacing between blocks: 3.5 m No. of parking spaces: 24 Frontage - 70.5m Width - 48.5m Road width - 10m Plot area - 3419.25 sq.m Plot coverage – 21.7% FSI - 1.08 OSR - 705 sq.m Height - G+2 SETBACKS Front - 6m Side - 3.5m rear - 5m Driveway width - 7.2m, 3.6m Structure in Setback: Shed
  • 23. PAGE 16 SECURITY CABIN MOTOR ROOM UNUSED GARAGE OSR
  • 24. PAGE 17 Case Study 2: Special Building Serene Apartments, Shanthi Colony No. of blocks: 1 No. of units: 4 No. of units per floor: 1 No. of parking spaces: 8 Frontage - 16m Width - 29.7m Road width - 10m Plot area - 475.2 sq.m Plot coverage - 52.7% FSI - 0.8 Height - stilt + 4 Driveway – 4m No. of parking spaces: 8 SETBACKS: Front-4m Side-4m Rear- 5m
  • 25. PAGE 1 Case Study 3: Multi-storeyed Building Pace Prana, Anna Nagar West No. of blocks: 6 No. of units: 108 No. of units per block: 18 No. of parking spaces: 268 Frontage - 122m Road width - 15.2m Plot area - 12140.46 sq.m Plot coverage - 28.37% FSI - 1.75 + 0.551 = 2.261 OSR required-1214.046 sq.m OSR provided- 1214.63 sq.m Height - G+9 SETBACKS Front - 7.3m Side - 7m rear - 7.6m Driveway width - 3.5m Spacing between blocks - 6.7m No. of parking spaces : 268