SlideShare a Scribd company logo
1 of 2
Value Icu, Ics, Icw of the circuit breaker is?
Value Icu, Ics, Icw of the circuit breaker is?
Ic (Interrupting Capacity) rating to withstand a short circuit. Maximum safety brake packages. It's typically
configured to withstand the current game. As kA. Ic shows that the breakers. Using it is very safe nut. I
just select the charge current Ic must know the short circuit current. At that point first.
Rated to withstand high short circuit current. Picks Interrupting Capacity (Ic) according to the IEC60947-2
standard, can be divided into four categories during the year.
*** 1) Icu or Icn (Rated short-circuit breaking capacity).
Coordinates the flow resistance means that shortcut. Circuit highest safety brake. Parker is specified as
standard value. The rms of AC The components are considered transient DC (the DC. Transient) Zero
Current Rating in the Industry sector. Industrial value called Icu (Rated ultimate sc breaking capacity)
called the housing sector. The unit is usually Icn kA rms test the Icu or Icn according to IEC has three
characteristics.
1.1) Operating sequences (open-close /. open) is tested to withstand the current cutoff. The closed circuit
and open circuit. The Breakers now have the new shortcut. Cycle
1.2) Current and voltage phase displacement is tested to withstand the current cutoff. The power factor of
the circuit, which found that if the power factor = 1 to disconnect circuits easier, and if power factor is
lower how much Vojislav discharging cycle. The only difficult part This is consistent with the local. Most of
that power is. Cool lagging power factor and even a short circuit current high tech. These are (near the
generator or transformer size), the lower the power factor.
1.3) Dielectric withstand capability is a test of the insulation. Frame (case) of the circuit breaker after a
short-circuit. I still
*** 2) Icm (Rated making capacity).
Coordinates the flow resistance means that shortcut. The maximum peak current of the circuit breaker
and can withstand up to disconnect the circuit immediately. Any (instantaneous) force without delay.
Rated voltage (rated voltage) under certain conditions.
In alternating current peak is related to Icu value by a factor (k factor), which varies according to the
power factor of the short circuit.
- (Icu) to more than 6kA 10kA -> (power factor) = 0.5 -> (Icm) = 1.7 x Icu.
- (Icu) over 10kA to 20kA -> (power factor) = 0.3 -> (Icm) = 2 x Icu.
- (Icu) over 20kA to 50kA -> (power factor) = 0.25 -> (Icm) = 2.1 x Icu.
- (Icu) over 50kA -> (power factor) = 0.2 -> (Icm) = 2.2 x Icu.
*** 3) Icw (Rated short-time withstand current).
This value depends on its type. low voltage switchgear, which is divided into two groups.
3.1) A type switchgear system is no requirement to check. The delay in the operation of the device. Korn
magnetic trip (to cycle through unlocked stay. Possibly magnetic) and molded case circuit breaker, so
molded case CB. There is no value Icw.
3.2) Type B is a switchgear system can delay the release. The cycle has to be made. Discharging cycle is
sequenced (discrimination) in the breaker to close. Short circuit the band should release Therefore, the
circuit before the next (especially the main) which must withstand higher short circuit current. And that is
longer than the time. This by itself does not release cycle and. No damage, coordinates and short circuit
currents. The maximum tolerated breaker in. The case to delay this. Called short-time withstand current
rating (Icw) are identified by the Icw or t test with brakes. Correa, an electronic trip as Air circuit breaker or
molded case type, heavy duty.
In summary, the short circuit current Icw is most important. For breaker type B, which can withstand the
effects of Buganda. Temperature, stress and strain of the magnetic North. The place itself is not damaged
capacity. One time specified by the manufacturer.
*** 4) Ics (Rated service short short-circuit breaking capacity).
Let them know when that is. The disconnect circuit breaker after the game. Remove the short circuit first.
The breaker can then be tolerated. Short circuit on the same or next. Not relative to the value specified as
a percentage of Icu. Icu low as 25, 50, 75 and 100%.
Breaker identified as one of the Ics = 0.5 Icu means that when the circuit breaker. Reduce cycle after
cycle of the shortcut. The first The breaker can then be tolerated. Short circuit the next time it is equal to
50% of Icu.

More Related Content

What's hot

Surge arrester and surge suppressor on transformer
Surge arrester and surge suppressor on transformerSurge arrester and surge suppressor on transformer
Surge arrester and surge suppressor on transformerVIKAS KUMAR MANJHI
 
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)foyez ahammad
 
Vacuum circuit breaker selection of circuit breakers
Vacuum circuit breaker selection of circuit breakersVacuum circuit breaker selection of circuit breakers
Vacuum circuit breaker selection of circuit breakersshubham_bharadia
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakersali raza
 
Circuit Breaker and its types
Circuit Breaker and its typesCircuit Breaker and its types
Circuit Breaker and its typesRakesh Gothwal
 
Switch Gear & Protection (conventional circuit breaker)
Switch Gear & Protection	(conventional circuit breaker)Switch Gear & Protection	(conventional circuit breaker)
Switch Gear & Protection (conventional circuit breaker)Raviraj solanki
 
Unit 02 - Fuse and circuit breakers
Unit  02 -  Fuse and circuit breakersUnit  02 -  Fuse and circuit breakers
Unit 02 - Fuse and circuit breakersPremanandDesai
 
Selection criteria of all cb's
Selection criteria of all cb'sSelection criteria of all cb's
Selection criteria of all cb'sMustafa Ismail
 
MCB And Earth Leakage Circuit
MCB And Earth Leakage CircuitMCB And Earth Leakage Circuit
MCB And Earth Leakage CircuitNavin Patle
 
Circuit Breakers for Low Voltage Applications
Circuit Breakers for Low Voltage ApplicationsCircuit Breakers for Low Voltage Applications
Circuit Breakers for Low Voltage ApplicationsIsham Rashik
 
Fuses vs. Circuit Breakers
Fuses vs. Circuit BreakersFuses vs. Circuit Breakers
Fuses vs. Circuit BreakersSima Yildirim
 
Selection Of Circuit Breaker
Selection Of Circuit BreakerSelection Of Circuit Breaker
Selection Of Circuit BreakerRaviraj solanki
 
Air circuit breaker (ACB) Low-Voltage Miduim-Voltage High Voltage
Air circuit breaker (ACB) Low-Voltage Miduim-Voltage High VoltageAir circuit breaker (ACB) Low-Voltage Miduim-Voltage High Voltage
Air circuit breaker (ACB) Low-Voltage Miduim-Voltage High VoltageRathana Lan
 

What's hot (20)

Lighting arrester
Lighting arresterLighting arrester
Lighting arrester
 
Surge arrester and surge suppressor on transformer
Surge arrester and surge suppressor on transformerSurge arrester and surge suppressor on transformer
Surge arrester and surge suppressor on transformer
 
Circuit Breaker
Circuit BreakerCircuit Breaker
Circuit Breaker
 
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
SWITCH GEAR & PROTECTIVE DEVICE (EEN-437)
 
Vacuum circuit breaker selection of circuit breakers
Vacuum circuit breaker selection of circuit breakersVacuum circuit breaker selection of circuit breakers
Vacuum circuit breaker selection of circuit breakers
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
 
Low voltage circuit breakers
Low voltage circuit breakersLow voltage circuit breakers
Low voltage circuit breakers
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
 
Circuit Breaker and its types
Circuit Breaker and its typesCircuit Breaker and its types
Circuit Breaker and its types
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
 
Switch Gear & Protection (conventional circuit breaker)
Switch Gear & Protection	(conventional circuit breaker)Switch Gear & Protection	(conventional circuit breaker)
Switch Gear & Protection (conventional circuit breaker)
 
Report on MCB
Report on MCBReport on MCB
Report on MCB
 
Unit 02 - Fuse and circuit breakers
Unit  02 -  Fuse and circuit breakersUnit  02 -  Fuse and circuit breakers
Unit 02 - Fuse and circuit breakers
 
Selection criteria of all cb's
Selection criteria of all cb'sSelection criteria of all cb's
Selection criteria of all cb's
 
MCB And Earth Leakage Circuit
MCB And Earth Leakage CircuitMCB And Earth Leakage Circuit
MCB And Earth Leakage Circuit
 
Circuit Breakers for Low Voltage Applications
Circuit Breakers for Low Voltage ApplicationsCircuit Breakers for Low Voltage Applications
Circuit Breakers for Low Voltage Applications
 
Fuses vs. Circuit Breakers
Fuses vs. Circuit BreakersFuses vs. Circuit Breakers
Fuses vs. Circuit Breakers
 
Selection Of Circuit Breaker
Selection Of Circuit BreakerSelection Of Circuit Breaker
Selection Of Circuit Breaker
 
Air circuit breaker (ACB) Low-Voltage Miduim-Voltage High Voltage
Air circuit breaker (ACB) Low-Voltage Miduim-Voltage High VoltageAir circuit breaker (ACB) Low-Voltage Miduim-Voltage High Voltage
Air circuit breaker (ACB) Low-Voltage Miduim-Voltage High Voltage
 
Circuit breakers
Circuit breakersCircuit breakers
Circuit breakers
 

Similar to Value icu

Introduction-to-MV-Design-Guide.ppt
Introduction-to-MV-Design-Guide.pptIntroduction-to-MV-Design-Guide.ppt
Introduction-to-MV-Design-Guide.pptAhmed Ramadan
 
Fire Pump Short Circuit and WIC Considerations
Fire Pump Short Circuit and WIC ConsiderationsFire Pump Short Circuit and WIC Considerations
Fire Pump Short Circuit and WIC ConsiderationsJames S Nasby
 
changwon MVP, EMDB, SMDB & DB
changwon MVP, EMDB, SMDB & DBchangwon MVP, EMDB, SMDB & DB
changwon MVP, EMDB, SMDB & DBSheikh Imran
 
Switchgear Equipment in a Substation
Switchgear Equipment in a SubstationSwitchgear Equipment in a Substation
Switchgear Equipment in a SubstationMd. Atiqur Rahman
 
Vaccum Circuit Breaker
Vaccum Circuit BreakerVaccum Circuit Breaker
Vaccum Circuit BreakerRAHUL-GOPU
 
Measurement and Relay Indications.pptx
Measurement and Relay Indications.pptxMeasurement and Relay Indications.pptx
Measurement and Relay Indications.pptxEngrSyedGhulamMustaf
 
Experiments manual
Experiments manual Experiments manual
Experiments manual Ramesh Meti
 
“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...
“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...
“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...rohit nadella
 
Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...IJERA Editor
 
Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...IJERA Editor
 
Short circuit (wic) testing and parameters.
Short circuit (wic) testing and parameters.Short circuit (wic) testing and parameters.
Short circuit (wic) testing and parameters.Mustafa Ismail
 
Electrical Installation.pptx
Electrical Installation.pptxElectrical Installation.pptx
Electrical Installation.pptxbharath364108
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breakerdipak doud
 
Substation_equipment_ (1).pptx
Substation_equipment_ (1).pptxSubstation_equipment_ (1).pptx
Substation_equipment_ (1).pptxSatish Pydimarla
 
244109578 estandar-iec-60947-2-pdf
244109578 estandar-iec-60947-2-pdf244109578 estandar-iec-60947-2-pdf
244109578 estandar-iec-60947-2-pdfBarlomax
 

Similar to Value icu (20)

Introduction-to-MV-Design-Guide.ppt
Introduction-to-MV-Design-Guide.pptIntroduction-to-MV-Design-Guide.ppt
Introduction-to-MV-Design-Guide.ppt
 
Fire Pump Short Circuit and WIC Considerations
Fire Pump Short Circuit and WIC ConsiderationsFire Pump Short Circuit and WIC Considerations
Fire Pump Short Circuit and WIC Considerations
 
changwon MVP, EMDB, SMDB & DB
changwon MVP, EMDB, SMDB & DBchangwon MVP, EMDB, SMDB & DB
changwon MVP, EMDB, SMDB & DB
 
circuit breaker
circuit breakercircuit breaker
circuit breaker
 
L.v tech presentation 2
L.v tech presentation 2L.v tech presentation 2
L.v tech presentation 2
 
Switchgear Equipment in a Substation
Switchgear Equipment in a SubstationSwitchgear Equipment in a Substation
Switchgear Equipment in a Substation
 
Vaccum Circuit Breaker
Vaccum Circuit BreakerVaccum Circuit Breaker
Vaccum Circuit Breaker
 
Measurement and Relay Indications.pptx
Measurement and Relay Indications.pptxMeasurement and Relay Indications.pptx
Measurement and Relay Indications.pptx
 
Introduction to mv switchgear
Introduction to mv switchgearIntroduction to mv switchgear
Introduction to mv switchgear
 
Experiments manual
Experiments manual Experiments manual
Experiments manual
 
“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...
“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...
“STUDY OF THE PROTECTIVE EQUIPMENTS OF A SUBSTATION AND POWER FACTOR IMPROVEM...
 
Epcos 5
Epcos 5Epcos 5
Epcos 5
 
Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...
 
Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...Calculation and comparison of circuit breaker parameters in Power World Simul...
Calculation and comparison of circuit breaker parameters in Power World Simul...
 
Mcb Breaker
Mcb Breaker Mcb Breaker
Mcb Breaker
 
Short circuit (wic) testing and parameters.
Short circuit (wic) testing and parameters.Short circuit (wic) testing and parameters.
Short circuit (wic) testing and parameters.
 
Electrical Installation.pptx
Electrical Installation.pptxElectrical Installation.pptx
Electrical Installation.pptx
 
Circuit breaker
Circuit breakerCircuit breaker
Circuit breaker
 
Substation_equipment_ (1).pptx
Substation_equipment_ (1).pptxSubstation_equipment_ (1).pptx
Substation_equipment_ (1).pptx
 
244109578 estandar-iec-60947-2-pdf
244109578 estandar-iec-60947-2-pdf244109578 estandar-iec-60947-2-pdf
244109578 estandar-iec-60947-2-pdf
 

Recently uploaded

Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementDr. Deepak Mudgal
 
Post office management system project ..pdf
Post office management system project ..pdfPost office management system project ..pdf
Post office management system project ..pdfKamal Acharya
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...Amil baba
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayEpec Engineered Technologies
 
INTERRUPT CONTROLLER 8259 MICROPROCESSOR
INTERRUPT CONTROLLER 8259 MICROPROCESSORINTERRUPT CONTROLLER 8259 MICROPROCESSOR
INTERRUPT CONTROLLER 8259 MICROPROCESSORTanishkaHira1
 
Passive Air Cooling System and Solar Water Heater.ppt
Passive Air Cooling System and Solar Water Heater.pptPassive Air Cooling System and Solar Water Heater.ppt
Passive Air Cooling System and Solar Water Heater.pptamrabdallah9
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaOmar Fathy
 
8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessor8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessorAshwiniTodkar4
 
Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)ChandrakantDivate1
 
8th International Conference on Soft Computing, Mathematics and Control (SMC ...
8th International Conference on Soft Computing, Mathematics and Control (SMC ...8th International Conference on Soft Computing, Mathematics and Control (SMC ...
8th International Conference on Soft Computing, Mathematics and Control (SMC ...josephjonse
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptxJIT KUMAR GUPTA
 
Worksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxWorksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxMustafa Ahmed
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdfKamal Acharya
 
Computer Graphics Introduction To Curves
Computer Graphics Introduction To CurvesComputer Graphics Introduction To Curves
Computer Graphics Introduction To CurvesChandrakantDivate1
 
Danikor Product Catalog- Screw Feeder.pdf
Danikor Product Catalog- Screw Feeder.pdfDanikor Product Catalog- Screw Feeder.pdf
Danikor Product Catalog- Screw Feeder.pdfthietkevietthinh
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwaitjaanualu31
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdfKamal Acharya
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxSCMS School of Architecture
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdfAldoGarca30
 

Recently uploaded (20)

Ground Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth ReinforcementGround Improvement Technique: Earth Reinforcement
Ground Improvement Technique: Earth Reinforcement
 
Post office management system project ..pdf
Post office management system project ..pdfPost office management system project ..pdf
Post office management system project ..pdf
 
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
NO1 Top No1 Amil Baba In Azad Kashmir, Kashmir Black Magic Specialist Expert ...
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
INTERRUPT CONTROLLER 8259 MICROPROCESSOR
INTERRUPT CONTROLLER 8259 MICROPROCESSORINTERRUPT CONTROLLER 8259 MICROPROCESSOR
INTERRUPT CONTROLLER 8259 MICROPROCESSOR
 
Passive Air Cooling System and Solar Water Heater.ppt
Passive Air Cooling System and Solar Water Heater.pptPassive Air Cooling System and Solar Water Heater.ppt
Passive Air Cooling System and Solar Water Heater.ppt
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessor8086 Microprocessor Architecture: 16-bit microprocessor
8086 Microprocessor Architecture: 16-bit microprocessor
 
Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)Introduction to Artificial Intelligence ( AI)
Introduction to Artificial Intelligence ( AI)
 
8th International Conference on Soft Computing, Mathematics and Control (SMC ...
8th International Conference on Soft Computing, Mathematics and Control (SMC ...8th International Conference on Soft Computing, Mathematics and Control (SMC ...
8th International Conference on Soft Computing, Mathematics and Control (SMC ...
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Worksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptxWorksharing and 3D Modeling with Revit.pptx
Worksharing and 3D Modeling with Revit.pptx
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Computer Graphics Introduction To Curves
Computer Graphics Introduction To CurvesComputer Graphics Introduction To Curves
Computer Graphics Introduction To Curves
 
Danikor Product Catalog- Screw Feeder.pdf
Danikor Product Catalog- Screw Feeder.pdfDanikor Product Catalog- Screw Feeder.pdf
Danikor Product Catalog- Screw Feeder.pdf
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 
Signal Processing and Linear System Analysis
Signal Processing and Linear System AnalysisSignal Processing and Linear System Analysis
Signal Processing and Linear System Analysis
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 

Value icu

  • 1. Value Icu, Ics, Icw of the circuit breaker is? Value Icu, Ics, Icw of the circuit breaker is? Ic (Interrupting Capacity) rating to withstand a short circuit. Maximum safety brake packages. It's typically configured to withstand the current game. As kA. Ic shows that the breakers. Using it is very safe nut. I just select the charge current Ic must know the short circuit current. At that point first. Rated to withstand high short circuit current. Picks Interrupting Capacity (Ic) according to the IEC60947-2 standard, can be divided into four categories during the year. *** 1) Icu or Icn (Rated short-circuit breaking capacity). Coordinates the flow resistance means that shortcut. Circuit highest safety brake. Parker is specified as standard value. The rms of AC The components are considered transient DC (the DC. Transient) Zero Current Rating in the Industry sector. Industrial value called Icu (Rated ultimate sc breaking capacity) called the housing sector. The unit is usually Icn kA rms test the Icu or Icn according to IEC has three characteristics. 1.1) Operating sequences (open-close /. open) is tested to withstand the current cutoff. The closed circuit and open circuit. The Breakers now have the new shortcut. Cycle 1.2) Current and voltage phase displacement is tested to withstand the current cutoff. The power factor of the circuit, which found that if the power factor = 1 to disconnect circuits easier, and if power factor is lower how much Vojislav discharging cycle. The only difficult part This is consistent with the local. Most of that power is. Cool lagging power factor and even a short circuit current high tech. These are (near the generator or transformer size), the lower the power factor. 1.3) Dielectric withstand capability is a test of the insulation. Frame (case) of the circuit breaker after a short-circuit. I still *** 2) Icm (Rated making capacity). Coordinates the flow resistance means that shortcut. The maximum peak current of the circuit breaker and can withstand up to disconnect the circuit immediately. Any (instantaneous) force without delay. Rated voltage (rated voltage) under certain conditions.
  • 2. In alternating current peak is related to Icu value by a factor (k factor), which varies according to the power factor of the short circuit. - (Icu) to more than 6kA 10kA -> (power factor) = 0.5 -> (Icm) = 1.7 x Icu. - (Icu) over 10kA to 20kA -> (power factor) = 0.3 -> (Icm) = 2 x Icu. - (Icu) over 20kA to 50kA -> (power factor) = 0.25 -> (Icm) = 2.1 x Icu. - (Icu) over 50kA -> (power factor) = 0.2 -> (Icm) = 2.2 x Icu. *** 3) Icw (Rated short-time withstand current). This value depends on its type. low voltage switchgear, which is divided into two groups. 3.1) A type switchgear system is no requirement to check. The delay in the operation of the device. Korn magnetic trip (to cycle through unlocked stay. Possibly magnetic) and molded case circuit breaker, so molded case CB. There is no value Icw. 3.2) Type B is a switchgear system can delay the release. The cycle has to be made. Discharging cycle is sequenced (discrimination) in the breaker to close. Short circuit the band should release Therefore, the circuit before the next (especially the main) which must withstand higher short circuit current. And that is longer than the time. This by itself does not release cycle and. No damage, coordinates and short circuit currents. The maximum tolerated breaker in. The case to delay this. Called short-time withstand current rating (Icw) are identified by the Icw or t test with brakes. Correa, an electronic trip as Air circuit breaker or molded case type, heavy duty. In summary, the short circuit current Icw is most important. For breaker type B, which can withstand the effects of Buganda. Temperature, stress and strain of the magnetic North. The place itself is not damaged capacity. One time specified by the manufacturer. *** 4) Ics (Rated service short short-circuit breaking capacity). Let them know when that is. The disconnect circuit breaker after the game. Remove the short circuit first. The breaker can then be tolerated. Short circuit on the same or next. Not relative to the value specified as a percentage of Icu. Icu low as 25, 50, 75 and 100%. Breaker identified as one of the Ics = 0.5 Icu means that when the circuit breaker. Reduce cycle after cycle of the shortcut. The first The breaker can then be tolerated. Short circuit the next time it is equal to 50% of Icu.