This document discusses the effect of user-defined plastic hinges on nonlinear modeling of reinforced concrete frames for seismic analysis. It compares the results of pushover analysis using default hinge properties provided in guidelines versus user-defined hinge properties that account for varying amounts of transverse reinforcement. The study found that increasing the amount of transverse reinforcement, by decreasing the spacing from 200mm to 100mm, increases the displacement capacity of the frames by around 50% for a 7-story frame and 15% for a 4-story frame. While default hinge properties provide reasonable results, user-defined hinge properties better capture the effect of transverse reinforcement on hinge behavior and displacement capacity.
International Journal of Engineering Research and Development (IJERD)IJERD Editor
journal publishing, how to publish research paper, Call For research paper, international journal, publishing a paper, IJERD, journal of science and technology, how to get a research paper published, publishing a paper, publishing of journal, publishing of research paper, reserach and review articles, IJERD Journal, How to publish your research paper, publish research paper, open access engineering journal, Engineering journal, Mathemetics journal, Physics journal, Chemistry journal, Computer Engineering, Computer Science journal, how to submit your paper, peer reviw journal, indexed journal, reserach and review articles, engineering journal, www.ijerd.com, research journals,
yahoo journals, bing journals, International Journal of Engineering Research and Development, google journals, hard copy of journal,
Performance of Flat Slab Structure Using Pushover AnalysisIOSR Journals
Performance Based Seismic Engineering is the modern approach to earthquake resistant design. It
is a limit-state based design approach extended to cover complex range of issues faced by structural engineers.
Flat slabs are becoming popular and gaining importance as they are economical as compared to beam-column
connections in conventional slab. Many existing flat slabs may not have been designed for seismic forces so it is
important to study their response under seismic conditions and to evaluate seismic retrofit schemes. In this
paper we have discussed the results obtained by performing push over analysis on flat slabs by using most
common software SAP2000. A (G+7) frame having 5 bays is considered for analysis. It is observed that the
performance point of flat slab is more as compared to conventional building.
seismic response of multi storey building equipped with steel bracingINFOGAIN PUBLICATION
Steel bracing has proven to be one of the most effective systems in resisting lateral loads. Although its use to upgrade the lateral load capacity of existing Reinforced Concrete (RC) frames has been the subject of numerous studies, guidelines for its use in newly constructed RC frames still need to be developed. In this paper the study reveals that seismic performance of moment resisting RC frames with different patterns of bracing system. The three different types of bracings were used i.e. X - bracing system, V - bracing system and Inverted V - bracing system. This arrangement helped in reducing the structural response (i.e. displacement, interstorey drift, Shear Forces & Bending Moments) of the designed building structure. An (G+6) storey building was modelled and designed as per the code provisions of IS-1893:2002. And linear analysis is been carried out in the global X direction. The analysis was conducted with a view of accessing the seismic elastic performance of the building structure.
International Journal of Engineering Research and Development (IJERD)IJERD Editor
journal publishing, how to publish research paper, Call For research paper, international journal, publishing a paper, IJERD, journal of science and technology, how to get a research paper published, publishing a paper, publishing of journal, publishing of research paper, reserach and review articles, IJERD Journal, How to publish your research paper, publish research paper, open access engineering journal, Engineering journal, Mathemetics journal, Physics journal, Chemistry journal, Computer Engineering, Computer Science journal, how to submit your paper, peer reviw journal, indexed journal, reserach and review articles, engineering journal, www.ijerd.com, research journals,
yahoo journals, bing journals, International Journal of Engineering Research and Development, google journals, hard copy of journal,
Performance of Flat Slab Structure Using Pushover AnalysisIOSR Journals
Performance Based Seismic Engineering is the modern approach to earthquake resistant design. It
is a limit-state based design approach extended to cover complex range of issues faced by structural engineers.
Flat slabs are becoming popular and gaining importance as they are economical as compared to beam-column
connections in conventional slab. Many existing flat slabs may not have been designed for seismic forces so it is
important to study their response under seismic conditions and to evaluate seismic retrofit schemes. In this
paper we have discussed the results obtained by performing push over analysis on flat slabs by using most
common software SAP2000. A (G+7) frame having 5 bays is considered for analysis. It is observed that the
performance point of flat slab is more as compared to conventional building.
seismic response of multi storey building equipped with steel bracingINFOGAIN PUBLICATION
Steel bracing has proven to be one of the most effective systems in resisting lateral loads. Although its use to upgrade the lateral load capacity of existing Reinforced Concrete (RC) frames has been the subject of numerous studies, guidelines for its use in newly constructed RC frames still need to be developed. In this paper the study reveals that seismic performance of moment resisting RC frames with different patterns of bracing system. The three different types of bracings were used i.e. X - bracing system, V - bracing system and Inverted V - bracing system. This arrangement helped in reducing the structural response (i.e. displacement, interstorey drift, Shear Forces & Bending Moments) of the designed building structure. An (G+6) storey building was modelled and designed as per the code provisions of IS-1893:2002. And linear analysis is been carried out in the global X direction. The analysis was conducted with a view of accessing the seismic elastic performance of the building structure.
EXPERIMENTAL MODELING OF IN FILLED RC FRAMES WITH OPENINGIAEME Publication
Reinforced concrete frames are usually infilled with masonry walls but, in most designs, both the shear strength capacity of these walls and the contribution of the infill panel openings on the shear strength of the infilled frame, especially in critical cases of seismic loading are generally ignored. This paper reports the results of an experimental study of the influence of central openings in the infill on the sway stiffness of reinforced concrete plane frames. A series of 1:4 scaled structural models with opening ratios from 0 to 50 percent in steps of 10 percent were designed, constructed and tested in the study to obtain the load - displacement profiles.
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Parametric study on slender column for flat plate structureeSAT Journals
Abstract This paper deals with effect of slender column on flat plate structure. The column is called slender if the height of is increased for functional purpose. The study is conducted on 18 flat-plate reinforced cement concrete (RCC) structural models. Among these18 models, 54 columns at three different locations (i.e. corner, edge and inner columns) are chosen for study. The models are developed using ETABS Software. Parametric study is performed by considering six different height of column ranging from 3048 mm to 6858 mm, using an increment of 762 mm along with three slab panels of size 4572 mm x 4572 mm, 6096 mm x6096 mm and 7620 mm x 7620 mm with five panels in both ways, considering both gravity and environmental load. The effect of slenderness ratio on load carrying capacity, design load and steel ratio is considered along with this the effect of additional moment due to slender compression member is also taken into account. It is observed that, columns in flat-plate structures are generally very sensitive if they are slender. It is observed that as the column length increases from 5502 mm and further, the steel ratio suddenly increases and it exceeds maximum allowed. As slenderness ratio increases, ratio of design load to the critical buckling load increases. Also resulting in increase of additional moment, decreasing load carrying capacity of column. This forces the design engineer to study effect of different parameter of the structure while designing high rise flat plate structure. Keywords: Flat Plate Structure, ETABS, Slenderness, Environmental load, design load and buckling load.
Optimization of a multistorey building by optimum positioning of shear walleSAT Journals
Abstract The shear wall is a structural element which is used to resist earthquake forces. These wall will consumptives shear forces & will prevent changing location-position of construction & consequently destruction. On other hand, shear wall arrangement must be absolutely accurate, if not, we will find negative effect instead. For example if the shear walls make an increase distance between mass centre and hardness centre, we cannot expect a good tensional behavior from the structure. In case of mass centre and hardness centre coincide with each other, at that time the distance of shear wall from the mass centre also plays an important role in the shear contribution of the shear wall. The bending moment, shear force, torsion, axial force contribution by rest of the structural element and the ultimate design of all the structural components also affected by that. A study has been carried out to determine the optimum Structural configuration of a multistory building by changing the shear wall locations radically. Four different cases of shear wall position for a 10 storey residential building with keeping zero eccentricity between mass centre and hardness centre have been analyzed and designed as a space frame system by computer application software, subjected to lateral and gravity loading in accordance with IS provisions. Keywords: Shear walls, Lateral loading, Zero eccentricity, Stresses, Design configuration.
EXPERIMENTAL MODELING OF IN FILLED RC FRAMES WITH OPENINGIAEME Publication
Reinforced concrete frames are usually infilled with masonry walls but, in most designs, both the shear strength capacity of these walls and the contribution of the infill panel openings on the shear strength of the infilled frame, especially in critical cases of seismic loading are generally ignored. This paper reports the results of an experimental study of the influence of central openings in the infill on the sway stiffness of reinforced concrete plane frames. A series of 1:4 scaled structural models with opening ratios from 0 to 50 percent in steps of 10 percent were designed, constructed and tested in the study to obtain the load - displacement profiles.
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Parametric study on slender column for flat plate structureeSAT Journals
Abstract This paper deals with effect of slender column on flat plate structure. The column is called slender if the height of is increased for functional purpose. The study is conducted on 18 flat-plate reinforced cement concrete (RCC) structural models. Among these18 models, 54 columns at three different locations (i.e. corner, edge and inner columns) are chosen for study. The models are developed using ETABS Software. Parametric study is performed by considering six different height of column ranging from 3048 mm to 6858 mm, using an increment of 762 mm along with three slab panels of size 4572 mm x 4572 mm, 6096 mm x6096 mm and 7620 mm x 7620 mm with five panels in both ways, considering both gravity and environmental load. The effect of slenderness ratio on load carrying capacity, design load and steel ratio is considered along with this the effect of additional moment due to slender compression member is also taken into account. It is observed that, columns in flat-plate structures are generally very sensitive if they are slender. It is observed that as the column length increases from 5502 mm and further, the steel ratio suddenly increases and it exceeds maximum allowed. As slenderness ratio increases, ratio of design load to the critical buckling load increases. Also resulting in increase of additional moment, decreasing load carrying capacity of column. This forces the design engineer to study effect of different parameter of the structure while designing high rise flat plate structure. Keywords: Flat Plate Structure, ETABS, Slenderness, Environmental load, design load and buckling load.
Optimization of a multistorey building by optimum positioning of shear walleSAT Journals
Abstract The shear wall is a structural element which is used to resist earthquake forces. These wall will consumptives shear forces & will prevent changing location-position of construction & consequently destruction. On other hand, shear wall arrangement must be absolutely accurate, if not, we will find negative effect instead. For example if the shear walls make an increase distance between mass centre and hardness centre, we cannot expect a good tensional behavior from the structure. In case of mass centre and hardness centre coincide with each other, at that time the distance of shear wall from the mass centre also plays an important role in the shear contribution of the shear wall. The bending moment, shear force, torsion, axial force contribution by rest of the structural element and the ultimate design of all the structural components also affected by that. A study has been carried out to determine the optimum Structural configuration of a multistory building by changing the shear wall locations radically. Four different cases of shear wall position for a 10 storey residential building with keeping zero eccentricity between mass centre and hardness centre have been analyzed and designed as a space frame system by computer application software, subjected to lateral and gravity loading in accordance with IS provisions. Keywords: Shear walls, Lateral loading, Zero eccentricity, Stresses, Design configuration.
Seismic evelution of rc space frame with rectangular and equivalent square co...eSAT Publishing House
IJRET : International Journal of Research in Engineering and Technology is an international peer reviewed, online journal published by eSAT Publishing House for the enhancement of research in various disciplines of Engineering and Technology. The aim and scope of the journal is to provide an academic medium and an important reference for the advancement and dissemination of research results that support high-level learning, teaching and research in the fields of Engineering and Technology. We bring together Scientists, Academician, Field Engineers, Scholars and Students of related fields of Engineering and Technology
Effect of variation of plastic hinge length on the results of non linear anal...eSAT Journals
Abstract The nonlinear Static procedure also well known as pushover analysis is method where in monotonically increasing loads are applied to the structure till the structure is unable to resist any further load. It is a popular tool for seismic performance evaluation of existing and new structures. In literature lot of research has been carried out on conventional pushover analysis and after knowing deficiency efforts have been made to improve it. But actual test results to verify the analytically obtained pushover results are rarely available. It has been found that some amount of variation is always expected to exist in seismic demand prediction of pushover analysis. Initial study is carried out by considering user defined hinge properties and default hinge length. Attempt is being made to assess the variation of pushover analysis results by considering user defined hinge properties and various hinge length formulations available in literature and results compared with experimentally obtained results based on test carried out on a G+2 storied RCC framed structure. For the present study two geometric models viz bare frame and rigid frame model is considered and it is found that the results of pushover analysis are very sensitive to geometric model and hinge length adopted. Keywords: Pushover analysis, Base shear, Displacement, hinge length, moment curvature analysis
Effect of variation of plastic hinge length on the results of non linear anal...eSAT Journals
Abstract The nonlinear Static procedure also well known as pushover analysis is method where in monotonically increasing loads are applied to the structure till the structure is unable to resist any further load. It is a popular tool for seismic performance evaluation of existing and new structures. In literature lot of research has been carried out on conventional pushover analysis and after knowing deficiency efforts have been made to improve it. But actual test results to verify the analytically obtained pushover results are rarely available. It has been found that some amount of variation is always expected to exist in seismic demand prediction of pushover analysis. Initial study is carried out by considering user defined hinge properties and default hinge length. Attempt is being made to assess the variation of pushover analysis results by considering user defined hinge properties and various hinge length formulations available in literature and results compared with experimentally obtained results based on test carried out on a G+2 storied RCC framed structure. For the present study two geometric models viz bare frame and rigid frame model is considered and it is found that the results of pushover analysis are very sensitive to geometric model and hinge length adopted. Keywords: Pushover analysis, Base shear, Displacement, hinge length, moment curvature analysis
Quality defects in TMT Bars, Possible causes and Potential Solutions.PrashantGoswami42
Maintaining high-quality standards in the production of TMT bars is crucial for ensuring structural integrity in construction. Addressing common defects through careful monitoring, standardized processes, and advanced technology can significantly improve the quality of TMT bars. Continuous training and adherence to quality control measures will also play a pivotal role in minimizing these defects.
TECHNICAL TRAINING MANUAL GENERAL FAMILIARIZATION COURSEDuvanRamosGarzon1
AIRCRAFT GENERAL
The Single Aisle is the most advanced family aircraft in service today, with fly-by-wire flight controls.
The A318, A319, A320 and A321 are twin-engine subsonic medium range aircraft.
The family offers a choice of engines
About
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Technical Specifications
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
Key Features
Indigenized remote control interface card suitable for MAFI system CCR equipment. Compatible for IDM8000 CCR. Backplane mounted serial and TCP/Ethernet communication module for CCR remote access. IDM 8000 CCR remote control on serial and TCP protocol.
• Remote control: Parallel or serial interface
• Compatible with MAFI CCR system
• Copatiable with IDM8000 CCR
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
Application
• Remote control: Parallel or serial interface.
• Compatible with MAFI CCR system.
• Compatible with IDM8000 CCR.
• Compatible with Backplane mount serial communication.
• Compatible with commercial and Defence aviation CCR system.
• Remote control system for accessing CCR and allied system over serial or TCP.
• Indigenized local Support/presence in India.
• Easy in configuration using DIP switches.
Sachpazis:Terzaghi Bearing Capacity Estimation in simple terms with Calculati...Dr.Costas Sachpazis
Terzaghi's soil bearing capacity theory, developed by Karl Terzaghi, is a fundamental principle in geotechnical engineering used to determine the bearing capacity of shallow foundations. This theory provides a method to calculate the ultimate bearing capacity of soil, which is the maximum load per unit area that the soil can support without undergoing shear failure. The Calculation HTML Code included.
Hybrid optimization of pumped hydro system and solar- Engr. Abdul-Azeez.pdffxintegritypublishin
Advancements in technology unveil a myriad of electrical and electronic breakthroughs geared towards efficiently harnessing limited resources to meet human energy demands. The optimization of hybrid solar PV panels and pumped hydro energy supply systems plays a pivotal role in utilizing natural resources effectively. This initiative not only benefits humanity but also fosters environmental sustainability. The study investigated the design optimization of these hybrid systems, focusing on understanding solar radiation patterns, identifying geographical influences on solar radiation, formulating a mathematical model for system optimization, and determining the optimal configuration of PV panels and pumped hydro storage. Through a comparative analysis approach and eight weeks of data collection, the study addressed key research questions related to solar radiation patterns and optimal system design. The findings highlighted regions with heightened solar radiation levels, showcasing substantial potential for power generation and emphasizing the system's efficiency. Optimizing system design significantly boosted power generation, promoted renewable energy utilization, and enhanced energy storage capacity. The study underscored the benefits of optimizing hybrid solar PV panels and pumped hydro energy supply systems for sustainable energy usage. Optimizing the design of solar PV panels and pumped hydro energy supply systems as examined across diverse climatic conditions in a developing country, not only enhances power generation but also improves the integration of renewable energy sources and boosts energy storage capacities, particularly beneficial for less economically prosperous regions. Additionally, the study provides valuable insights for advancing energy research in economically viable areas. Recommendations included conducting site-specific assessments, utilizing advanced modeling tools, implementing regular maintenance protocols, and enhancing communication among system components.
Explore the innovative world of trenchless pipe repair with our comprehensive guide, "The Benefits and Techniques of Trenchless Pipe Repair." This document delves into the modern methods of repairing underground pipes without the need for extensive excavation, highlighting the numerous advantages and the latest techniques used in the industry.
Learn about the cost savings, reduced environmental impact, and minimal disruption associated with trenchless technology. Discover detailed explanations of popular techniques such as pipe bursting, cured-in-place pipe (CIPP) lining, and directional drilling. Understand how these methods can be applied to various types of infrastructure, from residential plumbing to large-scale municipal systems.
Ideal for homeowners, contractors, engineers, and anyone interested in modern plumbing solutions, this guide provides valuable insights into why trenchless pipe repair is becoming the preferred choice for pipe rehabilitation. Stay informed about the latest advancements and best practices in the field.
Final project report on grocery store management system..pdfKamal Acharya
In today’s fast-changing business environment, it’s extremely important to be able to respond to client needs in the most effective and timely manner. If your customers wish to see your business online and have instant access to your products or services.
Online Grocery Store is an e-commerce website, which retails various grocery products. This project allows viewing various products available enables registered users to purchase desired products instantly using Paytm, UPI payment processor (Instant Pay) and also can place order by using Cash on Delivery (Pay Later) option. This project provides an easy access to Administrators and Managers to view orders placed using Pay Later and Instant Pay options.
In order to develop an e-commerce website, a number of Technologies must be studied and understood. These include multi-tiered architecture, server and client-side scripting techniques, implementation technologies, programming language (such as PHP, HTML, CSS, JavaScript) and MySQL relational databases. This is a project with the objective to develop a basic website where a consumer is provided with a shopping cart website and also to know about the technologies used to develop such a website.
This document will discuss each of the underlying technologies to create and implement an e- commerce website.