Hebei RuiD Cooling Tower Parts Manufacturer Co., Ltd. specializes in commercial and industrial PVC fills for cooling towers since 1976. The company operates advanced facilities for designing, developing, and manufacturing PVC and CPVC cooling tower parts and fills. Their goal is to be a leading provider of these products to meet clients' needs. They produce a wide range of PVC and CPVC fills in various sizes, styles, and materials to suit different applications. Honeycomb fills are also offered, which provide efficient precipitation through their structure and large surface area.
This document provides a summary of the selection process for a water cooled chiller system for Comin Khmere Co. Ltd. The following key steps are described:
1) A building load calculation using HAP software determined a total cooling load of 2357 kW. This required selecting a chiller with a 843.9 kW cooling capacity and 4 chillers total.
2) A 1012.68 kW cooling tower was selected based on the chiller condenser load and design parameters.
3) Pumps were selected to move 40.4 l/s of chilled water and 48.5 l/s of condenser water, with pressure drops of 270 kPa and 280 kPa respectively accounted
This document discusses storage tanks and piping facilities and inspection frequencies at a refinery. It notes that there are 120 total storage tanks, including 13 LPG spheres or mounded bullets. It describes the different types of atmospheric storage tank roofs and lists codes and standards for tank inspection and repair. The document outlines the importance of regular tank inspections to prevent leaks and catastrophic failures. It provides details on inspection techniques, frequencies, and protocols. Record keeping and various tests run during and after maintenance and inspection are also summarized.
HS2 Tunnel Ventilation - lessons learned from Crossrail 2018_12_12Quintus Murphy
Presentation to HS2 top management on the lessons learned from the Crossrail project using tunnel ventilation as a case study and with special emphasis on how to avoid costly project overruns in the future.
This document provides an overview of heat and power integration techniques for minimizing utility usage in process design. It discusses the temperature interval method, composite curve method, and linear programming method for pinch analysis to determine the minimum utility targets. It also covers constructing heat exchange networks to maximize energy recovery between hot and cold streams using the minimum number of heat exchangers while meeting the utility targets. Optimization of heat exchange network design requires balancing the tradeoff between capital costs from additional heat exchangers and operating costs from higher utility usage.
OISD-STD-117 Fire Protection Facilities for Petroleum Depots, Terminals, Pipe...AnupamaPanoli
The document outlines standards for fire protection facilities at petroleum depots, terminals, and pipeline installations in India. It discusses requirements for fire water systems, foam systems, control room protection, firefighting equipment, alarm systems, and organization of fire safety resources. The standards aim to minimize loss of life and property from fire through rapid containment and extinguishment. Requirements include fixed water spray and foam systems for large storage tanks, monitors and hydrants in hazardous areas, and clean agent systems for control rooms.
Basic training water based fire protectionSabrul Jamil
This document provides an introduction and overview of various water-based fire protection systems, including standpipe systems, wet pipe sprinkler systems, dry pipe sprinkler systems, deluge sprinkler systems, and pre-action sprinkler systems. It defines key terminology, describes common system components, and explains the purpose and function of different sprinkler head types and special application nozzles. Standards for installation and maintenance are also referenced.
This document provides a summary of the selection process for a water cooled chiller system for Comin Khmere Co. Ltd. The following key steps are described:
1) A building load calculation using HAP software determined a total cooling load of 2357 kW. This required selecting a chiller with a 843.9 kW cooling capacity and 4 chillers total.
2) A 1012.68 kW cooling tower was selected based on the chiller condenser load and design parameters.
3) Pumps were selected to move 40.4 l/s of chilled water and 48.5 l/s of condenser water, with pressure drops of 270 kPa and 280 kPa respectively accounted
This document discusses storage tanks and piping facilities and inspection frequencies at a refinery. It notes that there are 120 total storage tanks, including 13 LPG spheres or mounded bullets. It describes the different types of atmospheric storage tank roofs and lists codes and standards for tank inspection and repair. The document outlines the importance of regular tank inspections to prevent leaks and catastrophic failures. It provides details on inspection techniques, frequencies, and protocols. Record keeping and various tests run during and after maintenance and inspection are also summarized.
HS2 Tunnel Ventilation - lessons learned from Crossrail 2018_12_12Quintus Murphy
Presentation to HS2 top management on the lessons learned from the Crossrail project using tunnel ventilation as a case study and with special emphasis on how to avoid costly project overruns in the future.
This document provides an overview of heat and power integration techniques for minimizing utility usage in process design. It discusses the temperature interval method, composite curve method, and linear programming method for pinch analysis to determine the minimum utility targets. It also covers constructing heat exchange networks to maximize energy recovery between hot and cold streams using the minimum number of heat exchangers while meeting the utility targets. Optimization of heat exchange network design requires balancing the tradeoff between capital costs from additional heat exchangers and operating costs from higher utility usage.
OISD-STD-117 Fire Protection Facilities for Petroleum Depots, Terminals, Pipe...AnupamaPanoli
The document outlines standards for fire protection facilities at petroleum depots, terminals, and pipeline installations in India. It discusses requirements for fire water systems, foam systems, control room protection, firefighting equipment, alarm systems, and organization of fire safety resources. The standards aim to minimize loss of life and property from fire through rapid containment and extinguishment. Requirements include fixed water spray and foam systems for large storage tanks, monitors and hydrants in hazardous areas, and clean agent systems for control rooms.
Basic training water based fire protectionSabrul Jamil
This document provides an introduction and overview of various water-based fire protection systems, including standpipe systems, wet pipe sprinkler systems, dry pipe sprinkler systems, deluge sprinkler systems, and pre-action sprinkler systems. It defines key terminology, describes common system components, and explains the purpose and function of different sprinkler head types and special application nozzles. Standards for installation and maintenance are also referenced.
[Faye c. mc_quiston_,_jerald_d._parker_,_jeffrey_d.Akeel Zanghana
This document provides an overview of the 6th edition of the textbook "Heating, Ventilating, and Air Conditioning: Analysis and Design" by Faye C. McQuiston, Jerald D. Parker, and Jeffrey D. Spitler. The summary includes:
1) The textbook covers fundamental concepts of HVAC systems as well as analysis and design of air conditioning, heating, ventilation, and indoor air quality systems.
2) It provides an introduction to HVAC units and dimensions, moist air properties, comfort and indoor environmental quality, heat transfer in buildings, heating and cooling load calculations, energy calculations, fans and air distribution, and refrigeration systems.
3) The 6th
Topic 04 chilled beam system note version smallpnnazz
Chilled beam systems are an alternative to conventional HVAC systems like VAV that use beams suspended from ceilings to cool rooms. Water is circulated through pipes in the beams to absorb heat from the air. As the air around the beam cools, it falls to the floor and is replaced by warmer rising air, creating convection currents. There are passive and active beam types. Passive beams rely on natural convection while active beams integrate supply air nozzles. Chilled beams provide cooling through both radiation and convection with benefits like lower energy use and better indoor air quality compared to conventional systems.
Design, Installation and Testing of the VRF SystemSocheat Veng
The document provides details about the design, installation, and testing of a VRF air conditioning system at the TK Royal One building in Cambodia.
[1] It describes the components of a Panasonic VRF system, including outdoor units, indoor units, and compressor types. Load calculations were performed using estimation and manual methods to determine a total cooling load of 109.8kW was required.
[2] An outdoor unit model U-40ME2R8 with 113kW maximum cooling capacity was selected. Four indoor ducted units were chosen for the conference hall.
[3] The installation process for air ducts, copper pipes, drain pipes, and outdoor/indoor units is
FOR DOWNLOAD THIS GO THROUGH THIS BELOW LINK
https://ezazsidd1993.stores.instamojo.com/?ref=profile_bar
INTRODUCTION OF FIRE FIGHTING
FIRE FIGHTING NETWORK COMPONENTS
Manual Fire Fighting System
Standpipe System-Landing Valve(L.V) ,Fire Hose Cabinet(F.H.C).
Fire Hydrant(F.H).
Fire Department Connection(F.D.C).
Portable Fire Extinguishers.
Pipe Types& connecting of pipes.
Pipe Accessories, Supports & Valves.
Water Source & Pumping Station.
The revolutionary Water-Mist technology. Low Pressure & High Pressure Water-Mist. Design calculations, Standards, Applications, Limitations. Alternative to Gas suppression - sprinkler systems.
Contact: 95949-66462
This document outlines calculations for a mechanical smoke ventilation system for a basement floor with a store. It determines the heat release rate and smoke mass flow rate based on the fire area and assumptions. It then calculates the required air flow rate, duct size, and fan specifications. The system will include two exhaust fans of 18,500 CFM each and two fresh air intake fans of 10,500 CFM each, all located on the roof. The ducts will be sized to accommodate the required air flow rates. The entrance areas are determined to provide sufficient fresh air intake.
Presentación de Iñaki Ibarrondo, Jefe del Servicio de Seguridad Industrial del Gobierno Vasco en la Jornada de AVEQ-KIMIKA sobre el Reglamento de Equipos a Presión
This document provides specifications for horizontal and vertical fire-fighting pumps and packages that meet UNI EN 12845 and UNI EN 12259-12 standards. It includes performance ranges, dimensions, materials, and test procedures for horizontal split-case centrifugal pumps and vertical shaft turbine pumps. Installation diagrams and specifications are also provided for electric motor and diesel engine driven fire pump sets with controllers.
This document provides guidelines for fireproofing structures and critical systems at Chevron facilities. It discusses where fireproofing is needed, required protection levels, and recommended materials. Fireproofing is warranted for structures supporting high-risk equipment within 50 feet of potential fire sources and should protect against 1000°F for 3 hours. It recommends concrete or other cementitious coatings to achieve this, with standards specifying required thicknesses and weights based on the desired fire rating. The document serves as a supplement to the industry standard API RP 2218.
This presentation discusses NFPA 20 standards for fire pump sets. It provides background on NFPA and describes how NFPA sets standards for fire safety issues. NFPA 20 contains requirements for fire pumps, including that they must operate at 150% rated capacity at 65% total rated head. The presentation reviews pump types, motor and diesel engine selection requirements, control panels, accessories, and examples of electric and diesel pump sets.
Learn more about the differences between wet chemical pre-engineered restaurant systems and water sprinklers. Examines test results from both systems and includes the benefits and downfalls of each.
Smoke control and management systems aim to contain smoke and toxic gases to the area of origin using three main methods: containment, exhaust, and opposed airflow. Key goals are to prevent smoke from spreading and to maintain tenable conditions for evacuation. Systems often integrate with fire protection, HVAC, and other building systems. Proper design, installation, and regular acceptance testing are important to ensure effective operation.
This document provides definitions and information related to fire and explosion hazards. It defines key terms like hazard, risk, fire, explosion, ignition sources, and stages of combustion. It also discusses flash point, fire point, auto-ignition temperature, and flammability limits. The document outlines how to prevent and mitigate explosions through ventilation, ignition source control, containment, material substitution, and separation. It also discusses hazardous area classification and electrical equipment certification for different zones and gas/vapor groups.
1. A fire hydrant system provides a source of water to assist firefighters in battling a fire. It comprises pumps, pipes, hydrant valves, hoses, and nozzles that work together.
2. Water is stored in a reliable source like mains or a tank. Pipes direct the water from the source to hydrant valves located throughout buildings.
3. When pressure drops are detected, pumps boost water pressure to ensure an adequate flow of water can be directed through hoses and nozzles onto a fire.
This document discusses principles and methods for estimating cooling loads on buildings. It covers heat transfer mechanisms like conduction, convection and radiation. It explains factors that affect human comfort and methods to estimate different components of a cooling load, including conduction through surfaces, solar heat gain through windows, internal heat gains from occupants, lights, equipment and infiltration. An example calculation is provided to estimate the sensible and latent cooling loads on an office space from these various components. The purpose is to understand and quantify all sources of heat gain on a building to properly size air conditioning equipment.
The document discusses fire water pump systems, including their purpose of protecting life and property. It provides an overview of key components such as the pump, driver, controller, and sensing line arrangement. The document outlines pump characteristics, rated capacities, materials used, water supply sources, and types of pumps. It also discusses pump installation, jockey pumps, diesel, electric, and steam fire pump systems and their components. Testing organizations such as UL and FM are described.
Yongkang Jinle Outdoor Supplies Co., Ltd is a professional manufacturer of roof top tents, car side awnings, and camping trailers located in Yongkang, Zhejiang, China. They have 120 employees including 10 engineers and cover 16,000 square meters. Their yearly output is 40,000 sets with yearly sales of $15 million mainly to markets in the USA, EU, and Australia. Their products include soft shell and hard shell roof top tents, car side awnings, and camping trailers. They emphasize investment in production equipment, research and development, and new product designs.
[Faye c. mc_quiston_,_jerald_d._parker_,_jeffrey_d.Akeel Zanghana
This document provides an overview of the 6th edition of the textbook "Heating, Ventilating, and Air Conditioning: Analysis and Design" by Faye C. McQuiston, Jerald D. Parker, and Jeffrey D. Spitler. The summary includes:
1) The textbook covers fundamental concepts of HVAC systems as well as analysis and design of air conditioning, heating, ventilation, and indoor air quality systems.
2) It provides an introduction to HVAC units and dimensions, moist air properties, comfort and indoor environmental quality, heat transfer in buildings, heating and cooling load calculations, energy calculations, fans and air distribution, and refrigeration systems.
3) The 6th
Topic 04 chilled beam system note version smallpnnazz
Chilled beam systems are an alternative to conventional HVAC systems like VAV that use beams suspended from ceilings to cool rooms. Water is circulated through pipes in the beams to absorb heat from the air. As the air around the beam cools, it falls to the floor and is replaced by warmer rising air, creating convection currents. There are passive and active beam types. Passive beams rely on natural convection while active beams integrate supply air nozzles. Chilled beams provide cooling through both radiation and convection with benefits like lower energy use and better indoor air quality compared to conventional systems.
Design, Installation and Testing of the VRF SystemSocheat Veng
The document provides details about the design, installation, and testing of a VRF air conditioning system at the TK Royal One building in Cambodia.
[1] It describes the components of a Panasonic VRF system, including outdoor units, indoor units, and compressor types. Load calculations were performed using estimation and manual methods to determine a total cooling load of 109.8kW was required.
[2] An outdoor unit model U-40ME2R8 with 113kW maximum cooling capacity was selected. Four indoor ducted units were chosen for the conference hall.
[3] The installation process for air ducts, copper pipes, drain pipes, and outdoor/indoor units is
FOR DOWNLOAD THIS GO THROUGH THIS BELOW LINK
https://ezazsidd1993.stores.instamojo.com/?ref=profile_bar
INTRODUCTION OF FIRE FIGHTING
FIRE FIGHTING NETWORK COMPONENTS
Manual Fire Fighting System
Standpipe System-Landing Valve(L.V) ,Fire Hose Cabinet(F.H.C).
Fire Hydrant(F.H).
Fire Department Connection(F.D.C).
Portable Fire Extinguishers.
Pipe Types& connecting of pipes.
Pipe Accessories, Supports & Valves.
Water Source & Pumping Station.
The revolutionary Water-Mist technology. Low Pressure & High Pressure Water-Mist. Design calculations, Standards, Applications, Limitations. Alternative to Gas suppression - sprinkler systems.
Contact: 95949-66462
This document outlines calculations for a mechanical smoke ventilation system for a basement floor with a store. It determines the heat release rate and smoke mass flow rate based on the fire area and assumptions. It then calculates the required air flow rate, duct size, and fan specifications. The system will include two exhaust fans of 18,500 CFM each and two fresh air intake fans of 10,500 CFM each, all located on the roof. The ducts will be sized to accommodate the required air flow rates. The entrance areas are determined to provide sufficient fresh air intake.
Presentación de Iñaki Ibarrondo, Jefe del Servicio de Seguridad Industrial del Gobierno Vasco en la Jornada de AVEQ-KIMIKA sobre el Reglamento de Equipos a Presión
This document provides specifications for horizontal and vertical fire-fighting pumps and packages that meet UNI EN 12845 and UNI EN 12259-12 standards. It includes performance ranges, dimensions, materials, and test procedures for horizontal split-case centrifugal pumps and vertical shaft turbine pumps. Installation diagrams and specifications are also provided for electric motor and diesel engine driven fire pump sets with controllers.
This document provides guidelines for fireproofing structures and critical systems at Chevron facilities. It discusses where fireproofing is needed, required protection levels, and recommended materials. Fireproofing is warranted for structures supporting high-risk equipment within 50 feet of potential fire sources and should protect against 1000°F for 3 hours. It recommends concrete or other cementitious coatings to achieve this, with standards specifying required thicknesses and weights based on the desired fire rating. The document serves as a supplement to the industry standard API RP 2218.
This presentation discusses NFPA 20 standards for fire pump sets. It provides background on NFPA and describes how NFPA sets standards for fire safety issues. NFPA 20 contains requirements for fire pumps, including that they must operate at 150% rated capacity at 65% total rated head. The presentation reviews pump types, motor and diesel engine selection requirements, control panels, accessories, and examples of electric and diesel pump sets.
Learn more about the differences between wet chemical pre-engineered restaurant systems and water sprinklers. Examines test results from both systems and includes the benefits and downfalls of each.
Smoke control and management systems aim to contain smoke and toxic gases to the area of origin using three main methods: containment, exhaust, and opposed airflow. Key goals are to prevent smoke from spreading and to maintain tenable conditions for evacuation. Systems often integrate with fire protection, HVAC, and other building systems. Proper design, installation, and regular acceptance testing are important to ensure effective operation.
This document provides definitions and information related to fire and explosion hazards. It defines key terms like hazard, risk, fire, explosion, ignition sources, and stages of combustion. It also discusses flash point, fire point, auto-ignition temperature, and flammability limits. The document outlines how to prevent and mitigate explosions through ventilation, ignition source control, containment, material substitution, and separation. It also discusses hazardous area classification and electrical equipment certification for different zones and gas/vapor groups.
1. A fire hydrant system provides a source of water to assist firefighters in battling a fire. It comprises pumps, pipes, hydrant valves, hoses, and nozzles that work together.
2. Water is stored in a reliable source like mains or a tank. Pipes direct the water from the source to hydrant valves located throughout buildings.
3. When pressure drops are detected, pumps boost water pressure to ensure an adequate flow of water can be directed through hoses and nozzles onto a fire.
This document discusses principles and methods for estimating cooling loads on buildings. It covers heat transfer mechanisms like conduction, convection and radiation. It explains factors that affect human comfort and methods to estimate different components of a cooling load, including conduction through surfaces, solar heat gain through windows, internal heat gains from occupants, lights, equipment and infiltration. An example calculation is provided to estimate the sensible and latent cooling loads on an office space from these various components. The purpose is to understand and quantify all sources of heat gain on a building to properly size air conditioning equipment.
The document discusses fire water pump systems, including their purpose of protecting life and property. It provides an overview of key components such as the pump, driver, controller, and sensing line arrangement. The document outlines pump characteristics, rated capacities, materials used, water supply sources, and types of pumps. It also discusses pump installation, jockey pumps, diesel, electric, and steam fire pump systems and their components. Testing organizations such as UL and FM are described.
Yongkang Jinle Outdoor Supplies Co., Ltd is a professional manufacturer of roof top tents, car side awnings, and camping trailers located in Yongkang, Zhejiang, China. They have 120 employees including 10 engineers and cover 16,000 square meters. Their yearly output is 40,000 sets with yearly sales of $15 million mainly to markets in the USA, EU, and Australia. Their products include soft shell and hard shell roof top tents, car side awnings, and camping trailers. They emphasize investment in production equipment, research and development, and new product designs.
Hengshui Jingtong Rubber Co., Ltd. specializes in manufacturing and exporting waterstop products since the establishment in 1983. Adhering to the principle that quality determines the success and failures. Our company pays much attention to quality managements and today we are one of the leading companies owning customers in many countries.
Waterstop products including PVC, TPV, HDPE and rubber waterstops
Two main ranges of products including waterstop series and strip waterstop series are supplied by our company. Waterstop series includes the products of PVC waterstop, HDPE waterstop, TPV & TPER waterstop, rubber waterstop, steel-edge waterstop as well reinforced waterstop. Meanwhile, strips waterstops contain PZ waterstop, butyl waterstop and mastic waterstops. Additionally, as your request, waterstops can be made of other materials such as EPDM and silicone, etc.
To suit your specific scheme, waterstops can be made to order as your designs, even with complex profiles and different materials. So if you want to make a custom order, don't forget to enclose your design drawing, sizes and standards.
Jingtong also can give you some professional advice about how to install the waterstops you purchased. If you have some questions, please feel free to contact us directly via sales@jointwaterstop.com.
This document describes an innovative method for manufacturing PVC tape with a 17% cost savings. The method involves coating PVC film with a specially compounded water-borne acrylic pressure sensitive adhesive without compromising quality. This allows for higher production speeds, a more compact machine design, lower costs, and an eco-friendly process compared to conventional PVC tape manufacturing. A cost analysis demonstrates a net cost savings of 17.73% per square meter using this new method.
tunnel and mine ventilation ducting catalogueKevin Yang
Jiangsu Sulong Eco-Technologies Co., Ltd is a Chinese manufacturer of PVC and coated fabric products. They produce three main product series: coated fabrics and membranes, ventilation hoses, and waterproof coiled materials. The company was established in 2007 and has five production lines and 23 patents. They supply products for construction, mining, and other industries and have received several quality certifications.
GRP Sectional Water Tank - Pipeco Industrypipecogroup
PIPECO INDUSTRIES is a company specializes in the development and
production of GRP Water tanks. Located in India, & Gimhae South Korea our largescale plant and research center are dedicated to ongoing development and production
to lead the industry
Contact us - +91 98881 40909 / 98453 33446
Mail id - sales@pipecogroup.com
This document describes a company called YWCT that designs and manufactures custom cooling towers. It offers both field-assembled and factory-made cooling tower models and series. The CING and FRPP series are field-assembled, with the CING using a concrete structure and the FRPP using a pultruded fiberglass structure. Both are erected on site. The document provides details on the construction, options, and specifications of these field-assembled cooling tower series.
Microcool general liquid cooling presentation 10215Scott Holland
- Wolverine has over 90 years of experience manufacturing heat transfer products and invented the first high performance heat transfer tubes.
- They have developed Micro Deformation Technology (MDT) to enhance flat surfaces for liquid cooling, creating custom cold plates.
- MDT can form fins or pins on surfaces in various configurations with heights from 1mm to 8mm and spacing from 3 fins/cm to 255 fins/cm.
- Standard and custom cold plates are offered for applications like power electronics and automotive cooling.
FPI-Corporate Brochure for information aboutAbdulbaset14
This document provides information about Composite Piping Solutions, a company that manufactures and installs composite pipe solutions. It details the company's global presence with factories and sales offices across Asia, the Middle East, Europe, Africa, and the Americas. The document outlines Composite Piping Solutions' product portfolio including fiberglass, thermoplastic composite, and spoolable pipes. It also describes the key industries served: Oil & Gas, Chemical & Industrial, Water & Infrastructure, and Marine & Offshore.
The document discusses various machines used in the manufacturing of PVC pipes. It describes in-line socketing machines that socket PVC pipes after cutting. It also mentions off-line PVC cutting machines for external threading, and PVC pipe slotting machines that can slot two pipes at a time. In-line printing machines can imprint company logos on PVC pipes. The benefits of PVC pipe manufacturing machines are also summarized.
Development of Special Purpose of profile Machine, PVC Fittings and PVC Pipe ...Atharva Naik
This presentation contain information about Development of Special Purpose of profile Machine, PVC Fittings and PVC Pipe Machine. This PPT is nothing but our industrial experience as intern at Supreme Gold PVT LTD Nanded.
Customer care and quality are at the core of everything we do and gaining ISO9001 accreditation status is a reflection of the excellence of Coastal’s management systems. Achieving recognition for our strong customer focus, well-defined in-house responsibilities and our quest for continual improvement, means you can be confident that a call to Coastal will be the only call you need to make for all your Joinery Hardware needs.
This document discusses sheet applications in the construction field, focusing on PVC and polyolefin sheets. It describes the materials, technologies, and applications for manufacturing rigid and foamed PVC sheets as well as foamed polyolefin sheets using extrusion. Example applications discussed include coverings for houses, windows, doors, advertising boards, tents, containers, and barrages. The technologies described include multi-component dosing units, twin screw extruders, pre-cooling units, polishing roll stacks, and process controls. Market data on raw material consumption trends in Europe is also presented.
Nanjing Feitian Glass Industry Co. Ltd. is a leading glass manufacturer in China established in 1993. They produce tempered glass, laminated glass, and insulating glass units for applications such as building facades, windows, and doors. The company has over 300 employees and exports over $5 million annually. Their glass products are certified to European and Chinese standards and their factory is ISO9001 certified.
Isuzu 3 ton water tank fire fighting truckBrianYao9
ChengLi special Automobile Co.,Ltd provides a quotation for an ISUZU 3 ton water tank fire fighting truck. The truck has a 2000kg liquid loading capacity, 95km/h maximum speed, and 20L/s fire pump rated flow. The chassis is an ISUZU QL1070A6KWY with a 2999cc engine. The truck has a 2000L water tank made of 3mm carbon steel and includes a water pump, piping system, car water cannon, fire control system, electrical equipment, and firefighting tools. The quotation price for the fire truck is USD 25,491 CIF Yangon, Myanmar port.
Mẫu thiết kế profile Công ty Tôn thép Đông Á bằng tiếng AnhSaoKim.com.vn
Mẫu thiết kế profile Công ty Tôn thép Đông Á bằng tiếng Anh với dung lượng 28 trang do Sao Kim thực hiện
Xem ngay các dự án thiết kế brochure được nhiều khách hàng lựa chọn nhất: http://www.saokim.com.vn/dich-vu/tai-lieu-marketing/thiet-ke-profile/
Liên hệ để được tư vấn thiết kế profile trực tiếp ngay hôm nay: 0964.699.499 (Chuyên gia Nguyễn Tuấn Hùng)
Shouju Industry (Group) Co., Ltd is a precision manufacturing company founded in 1987 that has since expanded to include multiple factories and offices worldwide. It provides services such as mold design and manufacturing, product R&D, precision injection molding, and engineering support. Its main business segments are automotive, packaging, and medical. Shouju aims to be a pioneer in precision manufacturing through honest business practices and mutual benefits with customers and employees. It has a large equipment portfolio and provides value-added services such as condition tracking and feedback optimization for customers.
We would like to present the supreme material for pitched roofs - QUEENTILE STONE COATED STEEL ROOFING.
Now the Company is expanding its sales market and searching for new partners and dealers.
- The company manufactures and repairs barrels and screws for transforming plastics, thermoplastics, rubber, and silicones. They can produce screws from 12-350mm in diameter with various surface treatments and tolerances down to 0.01mm.
- They produce bimetallic lined screws and barrels with different abrasion-resistant compounds to extend wear life when processing materials with heavy workloads like fiberglass.
- As an experienced company with over 30 years in the industry, they offer technical support 24/7 and customized solutions for barrels and screws along with repair services.
- The company manufactures and repairs barrels and screws for transforming plastics, thermoplastics, rubber, and silicones. They can produce screws from 12-350mm in diameter with various surface treatments and tolerances down to 0.01mm.
- They produce bimetallic lined screws and barrels with different abrasion-resistant compounds to increase wear life when processing materials with heavy workloads like fiberglass.
- As well as standard sizes, they can produce customized barrels and screws for single and double screw extruders and injection molding machines, including auxiliary parts. The company has over 30 years of experience in manufacturing and repair and provides 24/7 technical and mechanical support.
This document provides product specifications for Accu-Pac VF-19 PLUS anti-fouling fill sheets for cooling towers. The fill sheets are made of rigid PVC that is UV protected and resistant to chemicals, rot, fungi and bacteria. The corrugated fill sheets are formed into modules up to 24 inches wide, 23 5/8 inches high and 10 feet long, providing a surface area of at least 47 square feet per cubic foot. The fill modules are to be installed according to the manufacturer's recommendations, with care taken to ensure a close fit and protection from damage during installation.
The document provides instructions for servicing and repairing a ROCHEM Spacer Tube reverse osmosis module. It describes the components of the module, including the membrane element, spacers, and seals. It also provides details on assembly, specifications, flow path, and exploded/sectioned views of the module. The instructions are intended to guide maintenance like membrane replacement through a step-by-step process.
The document discusses the benefits of exercise for mental health. Regular physical activity can help reduce anxiety and depression and improve mood and cognitive functioning. Exercise causes chemical changes in the brain that may help protect against mental illness and improve symptoms.
Shandong Ocean Pipe Technology Co., Ltd. manufactures four series and dozens of specifications of fiberglass reinforced plastic pipes. Their main products include GRE pipes for offshore platforms and marine engineering, GRE pipes for oil fields, large diameter GRE pipes for chemical and LNG industries, and FRP pipes for fresh water and sewage disposal. The company's products have been widely used both domestically and internationally and have received certification from several international classification societies. Shandong Ocean Pipe aims to continue innovating and providing high quality GRE pipe products and technical services to customers.
He Bei Cheng Da FRP Co., Ltd. is a Chinese manufacturer of GRP tanks, FRP pressure vessels, and plastic pipes and fittings located in Hengshui, Hebei. The report summarizes an on-site audit conducted of the company by SGS on March 25, 2016. Key details include:
1) The company was established in 2002 and has 104 employees. It has passed ISO, ISO 14001, and OHSAS certifications.
2) The audit assessed the company's management systems, production capacity, quality control, and other areas.
3) The company produces FRP tanks, pressure vessels, and other products on machinery like fiberglass winding machines in
This document appears to provide technical details and measurements for a manhole structure, listing components such as screw, corner block, inside support H, tie rod, inside support, tie rod V, water in, outside ladder, water out, overflow drain, air vent, water level indicator, and various measurements.
Building a Raspberry Pi Robot with Dot NET 8, Blazor and SignalRPeter Gallagher
In this session delivered at NDC Oslo 2024, I talk about how you can control a 3D printed Robot Arm with a Raspberry Pi, .NET 8, Blazor and SignalR.
I also show how you can use a Unity app on an Meta Quest 3 to control the arm VR too.
You can find the GitHub repo and workshop instructions here;
https://bit.ly/dotnetrobotgithub
The Indian government has been working over the past few years to include elements of ITS in the transport sector. This standard ensures the optimal operation of the current transport infrastructure. It also increases the efficiency, safety, comfort, and quality of the system. That is why the government created the AIS-140 standard. Compliance with this standard means all vehicles used for public transit must have panic buttons and vehicle tracking modules installed. Nevertheless, in future in the standard protocol of AIS-140 you can expect fare collection and CCTV capabilities.
Get more information here: https://blog.watsoo.com/2023/12/27/all-about-prithvi-ais-140-gps-vehicle-tracker/
Google Calendar is a versatile tool that allows users to manage their schedules and events effectively. With Google Calendar, you can create and organize calendars, set reminders for important events, and share your calendars with others. It also provides features like creating events, inviting attendees, and accessing your calendar from mobile devices. Additionally, Google Calendar allows you to embed calendars in websites or platforms like SlideShare, making it easier for others to view and interact with your schedules.
1. Hebei RuiD Cooling Tower Parts Manufacturer Co., Ltd.
Cooling Tower Parts
Specialize in Commercial and Industrial PVC Fills Since 1976.
Web: http://www.pvccoolingfill.com
E-mail: info@pvccoolingfill.com
2. 1E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Hebei RuiD Cooling Tower Parts Manufacturer Co., Ltd. was founded in
1976 and rapidly increased its activities in the FRP Cooling Tower material
production market.
We operates the art productions facilities, combining the resources
necessary for design, development and manufacture of advanced PVC &
CPVC products from cutting-edge technologies for the chemical and food
industries, Water & Air Cooling waste water treatment and water supply.
RuiD quickly became the leader in the Cooling Tower China composite
industry. Our Cooling Tower Parts is involved in many mega-size cooling
tower projects, providing a total solution of detailed design, production for
the process industry, water treatment industry and more.
Our goal is to be the leader in providing commercial and industrial PVC Fills
for our clients' needs.
4. 3E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Material: PVC.
Fire classification: M2.
Typical sheet size: As requested.
Color: Black, blue, transparent or other.
With 42% Oxygen Index.
Working Temperature 65 °C.
●
●
●
●
●
●
●
●
●
●
Technical Parameters
Film fills to fit any application, any water quality level.
Widest range of flute geometries to control fouling.
High thermal performance options.
New tower construction as well as retrofit applications.
Feature
Available Styles
Brand: BAC
Size: 1220 × 1300 mm
Thickness: 0.30–0.35 mm
Flute: 19 mm
●
●
●
●
PVC CoolingTower Fills
Model No.: RDFill-01
Many modern cooling towers utilize efficient plastic film fills that maximize surface
area for evaporative cooling. Water is distributed onto the fill and spreads into a thin
film, increasing the air-water interface and allowing waste heat to evaporate at an
accelerated rate. The main factors driving fill selection are Total Suspended Solids
(TSS) levels, water make-up, intended treatment, and potential for contamination.
Brand: BAC
Size: 1333 mm × any length
Thickness: 0.28–0.33 mm
Flute: 19 mm
●
●
●
●
Model No.: RDFill-02
5. 4E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Brand: USA SPX MARLEY
Size:
●
●
915 mm × any length
1220 mm × any length
●
●
Thickness: 0.28–0.33 mm
Flute: 19 mm
●
●
Brand: China LIANGCHI
Size:
●
●
750 × 800 mm
750 × 1600 mm
750 × 1000 mm
●
●
●
Thickness: 0.28–0.33 mm
Flute: 20mm
●
●
Brand: Japan KUKEN
Size:
●
●
750 × 2000 mm
930 × 2000 mm
●
●
Thickness: 0.28–0.33 mm
Flute: 18 mm
●
●
Model No.: RDFill-04
Model No.: RDFill-05
Model No.: RDFill-03
Brand: KS
Size: 610 × 1200 mm
Thickness: 0.28–0.33 mm
Flute:
●
●
●
●
Model No.: RDFill-06
12 mm
19 mm
●
●
Brand: SPINDLE
Size:
●
●
850 × 1000 mm
1300 × 1000 mm
●
●
Thickness: 0.28–0.33 mm
Flute: 16 mm
●
●
Model No.: RDFill-07
6. 5E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Brand: ShangY
Size:
●
●
800 × 1000 mm
800 × 1200 mm
●
●
Thickness: 0.28–0.33 mm
Flute: 16 mm
●
●
Brand: SHINWA/EBARA
Size: 950 × 950 mm
Thickness: 0.28–0.33 mm
Flute: 20 mm
●
●
●
●
Model No.: RDFill-08
Model No.: RDFill-09
Brand: Black S
Size: 500 × 1030 mm
Thickness: 0.28–0.33 mm
Flute: 35 mm
●
●
●
●
Model No.: RDFill-10
Brand: Transparent S
Size: 500 × 1030 mm
Thickness: 0.28–0.33 mm
Flute: 35 mm
●
●
●
●
Model No.: RDFill-011
7. 6E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Brand: Air Inlet Louver
Size: 350 × 1000 mm
Thickness: 0.28-0.33 mm
Flute: Order
●
●
●
●
Brand: Dual Inclin
Size:
●
●
Model No.: RDFill-12
Model No.: RDFill-13
500 × 1000 mm
500 × 2000 mm
●
●
Thickness: 0.28–0.33 mm
Flute: 33mm
●
●
Brand: Transparent Dual Line
Size: 500 × 1000 mm
Thickness: 0.28–0.33 mm
lute: 25 mm
●
●
●
●
Model No.: RDFill-014
Brand: Seagull
Size: 500 × 2000 mm
Thickness: 0.30–0.35 mm
Flute: 22 mm
●
●
●
●
Model No.: RDFill-015
8. 7E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
CPVC CoolingTower Fills
Material: CPVC, polycarbon, ABS or other.
Material grade: Flame spread rate not to exceed 25 per ASTM E-84.
Working temperature: 75 °C to 85 °C.
Tensile strength: 6300 PSI.
Standard: ISO 9001:2008.
Typical sheet size: As request.
Color: Black, blue, transparent or other customized colors.
With 42% oxygen index.
●
●
●
●
●
●
●
●
CPVC cooling tower fill is an advanced products of PVC fills. The main materials of CPVC fills
are chlorine and polyvinyl chloride. It has excellent high temperature resistance, chemical
resistance, high mechanical strength and fire resistance performance.
Extremely high temperature resistance.
Compared with PVC fills and PP fills. The maximum working temperature of PVC fills are 65 °C and
PP is 90 °C. The maximum working temperature of C can achieve 100 °C. It can supplies maximum
pressure loading capacity but also supplies longest service life in the high temperature environments.
Corrosion resistance.
The high content of chlorine element supplies excellent chemical stability, it can resist acid, alkali,
salty and other organic solvent.
Fire resistance performance.
Fire resistance is the most outstanding performance of CPVC cooling tower fills. It can neither be
self-burning nor contribute to burning. The LOI (Limiting Oxygen Index) can achieve 46, which is the
most highest grade of fire resistance.
●
●
●
Feature
Technical Parameters
9. 8E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Available Styles
Material: CPVC
Brand: Japan KingSun
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 01
1220 × 610 mm
1800 × 305 mm
●
●
Thickness: 0.30 mm
Flute: 12 mm
●
●
Material: CPVC
Brand: SPX
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 02
915 mm × any length
1220 mm × any length
●
●
Thickness: 0.30 mm
Flute: 19 mm
●
●
Material: CPVC
Brand: Brentwood
Size: 1220 mm × 610 mm
Thickness: 0.28 mm
Flute: 19 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 03
Material: CPVC
Brand: Mayrly HoneyComb Drift Eliminator
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 04
Width: 50 mm/60 mm/70 mm
Length: 120 mm/1300 mm
●
●
Thickness: 0.30 mm
Flute: 20 mm
●
●
10. 9E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Material: CPVC
Brand: BAC
Size: 1220 × 1300 mm
Thickness: 0.33 mm
Flute: 19 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 05
Material: CPVC
Brand: Japan Kuken
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 06
750 × 2000 mm
930 × 2000 mm
●
●
Thickness: 0.30 mm
Flute: 18 mm
●
●
Material: CPVC
Brand: BAC
Size: 1300 mm width × any length
Thickness: 0.33 mm
Flute: 19 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 07
Material: CPVC
Brand: Liangchi
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 08
750 × 1600 mm
750 × 800 mm
●
●
Thickness: 0.30 mm
Flute: 20 mm
●
●
11. 10E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Material: CPVC
Brand: SY
Size: 1200 × 800 mm
Thickness: 0.32 mm
Flute: 16 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 09
Material: CPVC
Brand: Marley
Size: 915 mm width × any length
Thickness: 0.30 mm
Flute: 19 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 10
Material: CPVC
Brand: Spindle
Size: 850 × 1000 mm
Thickness: 0.35 mm
Flute: 16 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 11
Material: CPVC
Brand: Spindle
Size: 850 × 1000 mm
Thickness: 0.35 mm
Flute: 16 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 12
12. 11E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Material: CPVC
Brand: Renyuan
Size: 950 × 950 mm
Thickness: 0.33 mm
Flute: 20 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 13
Material: CPVC
Brand: Spindle
Size: 1000 × 1000 mm
Thickness: 0.33 mm
Flute: 16 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 14
Material: CPVC
Brand: S
Size: 1000 × 500 mm
Thickness: 0.30 mm
Flute: 35 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 15
Material: CPVC
Brand: S
Size: 1000 × 500 mm
Thickness: 0.30 mm
Flute: 30 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower fill 16
13. 12E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Material: CPVC
Brand: Dual Inclin
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 17
Material: CPVC
Brand: Offset
Size: 500 × 1000 mm
Thickness: 0.30 mm
Flute: 25 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 18
500 × 1000 mm
500 × 2000 mm
●
●
Thickness: 0.28–0.33 mm
Flute: 33 mm
●
●
Material: CPVC
Brand: Japan LINGSUN
Size:
●
●
●
Model No.: CPVC Cooling Tower Fill 19
Material: CPVC
Brand: Transparent S
Size: 500 × 1030 mm
Thickness: 0.28–0.33 mm
Flute: 35 mm
●
●
●
●
●
Model No.: CPVC Cooling Tower Fill 20
300 × 1200 mm
600 × 1200 mm
●
●
Thickness: 0.28–0.32 mm
Flute: 19 mm
●
●
14. 13E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Honeycomb Fills
Feature
Firm structure.
Large wetted perimeter.
Small hydraulic radius
Small volume.
Large specific surface area.
Anti-corrosion.
Anti-aging.
●
●
●
●
●
●
●
Temperature resistance.
Easy cleaning.
High treating efficiency.
Low maintenance.
Safe and non-toxic.
Wide range of applications.
●
●
●
●
●
●
Honeycomb fills are precipitation packings developed based on shallow settlement. It has
large wetted perimeter, small hydraulic radius. When operating, the honeycomb fills can
supply good laminar conditions and ensure the high efficiency of particle precipitation
without being disturbing by the turbulent flow. Additional, it can speed up the filtration of
water and particle and shorten precipitation distance.
Table 1: Common Specs of Honeycomb Fills
Item Material Specification
Raw Material
Thickness
(mm)
Sheet Quantity
(pieces/m3
)
Density
(m3
/mt)
Weight
(kg/m3
)
HFS-01 PVC 25 0.45 80 17.2 58
HFS-02 PVC 30 0.45 68 20.8 48
HFS-03 PVC 35 0.5 40 22.2 45
HFS-04 PVC 40 0.5 50 25 40
HFS-05 PVC 50 0.6 30 25 40
HFS-06 PVC 80 0.8 20 28.6 35
HFS-07 PP 25 0.5 80 22.2 45
HFS-08 PP 30 0.5 68 27.8 36
HFS-09 PP 35 0.5 40 23 32
HFS-10 PP 40 0.5 50 37 27
HFS-11 PP 50 0.6 30 21 28
HFS-12 PP 80 0.8 20 27 -
15. 14E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Available Styles
PP material honeycomb fill pack PVC material honeycomb fill pack
1.By material
Inclined type honeycomb fill Straight type honeycomb fill
2.By assemble structure
White color honeycomb fill
3.By color
Blue color honeycomb fill Black color honeycomb fill
16. 15E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Honeycomb cooling tower fill Honeycomb drift eliminator
4.By function
Counter flow honeycomb fills Biphasic weave honeycomb fills
5.Other types of honeycomb fills
Oblique weave honeycomb fills Crossflow type honeycomb fills
17. 16E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
High-temp Resistant CoolingTower Fills
Many modern cooling towers utilize efficient plastic film fills that maximize surface
area for evaporative cooling. Water is distributed onto the fill and spreads into a
thin film, increasing the air-water interface and allowing waste heat to evaporate
at an accelerated rate. The main factors driving fill selection are Total Suspended
Solids (TSS) levels, water make-up, intended treatment, and potential for
contamination.
Technical Parameters
Material: CPVC, Polycarbon, ABS or other.
Material grade: Flame Spread Rate Not to Exceed 25 Per ASTM E-84.
Tensile strength: 6300 PSI.
Standard: ISO 9001:2008 (Iaf). Required certification shall be provided later.
Working temperature 75 °C to 85 °C.
With 42% oxygen index.
●
●
●
●
●
●
Feature
Film fills to fit any application, any water quality level.
Widest range of flute geometries to control fouling.
High thermal performance options.
New tower construction as well as retrofit applications.
●
●
●
●
18. 17E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Air Inlet Louvers & Drift Eliminator
Drift eliminators are used to control water loss from a cooling tower by limiting the amount
of circulating water droplets that are emitted with the exhaust air of the tower. Since
drift droplets contain the same chemical and particulate matter of the circulating water
from which they originate, they can cause numerous detrimental effects on surrounding
equipment and the environment. The cooling tower industry uses drift rate to compare drift
eliminator performance, a relationship that correlates droplet capture efficiency to the water
circulation rate in a tower. RUID’s drift eliminators are specifically designed to achieve
maximum drift removal efficiency in both crossflow and counterflow tower applications
with various product options available to minimize pressure drop, drift loss, cost, or a
combination of all three.
Model No.: RD-DE-01
Brand: BAC Drift Eliminator
Size: 140 mm × any length
●
●
Model No.: RD-DE-02
Brand: Marley Drift Eliminator
Size: 140 mm × any length
●
●
Model No.: RD-DE-03
Brand: Evapco
Size: 140 mm × any length
●
●
Model No.: RD-DE-04
Brand: PVC Air Inlet Louver
without flat sheet
Size: 140 mm × any length
●
●
Model No.: RD-DE-05
Brand: PVC Air Inlet Louver
with flat sheet
Size: 140 mm × any length
●
●
Model No.: RD-DE-06
Brand: AIR LOUVER
Size: 355 × 1000 mm
●
●
19. 18E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Model No.: RD-DE-07
Brand: Blade Type Drift
Eliminator
Size: 140 mm × any length
●
●
Model No.: RD-DE-08
Brand: Spig Drift Eliminator
Size: 140 mm × any length
●
●
Model No.: RD-DE-09
Brand: Drift Eliminator
Size: 175 × 30 mm
●
●
Model No.: RD-DE-10
Brand: Multi Wave
Size: 160 mm × 45 mm
●
●
Model No.: RD-DE-11
Brand: Multi Dimension
Size: 140 mm × any length
●
●
Model No.: RD-DE-12
Brand: M Shape Eliminator
Size: 160 mm × 40 mm
●
●
Model No.: RD-DE-13
Brand: Water Eliminator
Size: 145 × 21 mm
●
●
Model No.: RD-DE-14
Brand: S DRIFT ELIMINATOR
Size: 220 mm × any length
●
●
Model No.: RD-DE-15
Brand: Brentwood Drift
Eliminator
●
20. 19E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
PP CoolingTower Fills
PP cooling tower fill, an alternative to the PVC cooling tower fills, is made
of polypropylene material with superior quality and features. PP cooling
tower fill is suitable for counter flow and cross flow cooling towers. It is
widely used in power station cooling towers, process cooling towers, air
conditioning cooling towers.
High temperature resistance.
It features higher temperature resistance than PVC cooling towers. It can remain good
performance in the high temperature up to 90°C while the 65°C of PVC fill to ensure good
performance in more applications.
Welded bonding technology.
Another advantage of PP cooling tower fill is the attachment of block. As we all know,
the PVC fills is glued together into blocks. But the PP cooling tower fills are welded into
accurate honeycomb opening at the surface of the fill blocks. In this way, it can prevent PP
cooling tower fill breaking up over time and breaking down of the PP fill blocks.
●
●
Feature
21. 20E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Lamella Clarifier Inclined Settler
Lamella clarifier inclined tube settler has high efficient solid and liquid filtering performance.
A lamella clarifier or inclined plate settler (IPS) is a type of high efficient setter designed to
remove particulates from liquids. Compared with conventional clarifier, treatment capacity
of lamella clarifier is increased 7-10 times. In this system, the inclined tube settler is the
most important component.
The inclined settler can be made into plate or blocks, which is known as the corrugated
plate settler for lamella clarifier and inclined tuber settler for lamella clarifier. Raw materials
are made into PP sheet, then the PP sheet are pressed and corrugated into inclined sheets.
Then cut them into suitable pieces to form the inclined plates. The inclined plates can be
assembled into inclined tube/blocks settlers as customers requirements.
Technical Parameters
Material: PP.
Aperture: 25 mm, 30 mm, 35 mm, 40 mm, 50 mm, 60 mm and 80 mm.
Thickness: 0.45–0.8 mm.
Plate/block pitch angle: 45° to 70°.
Tube/plate length: 1–2 m.
Sheet size: Commonly is 1000 × 1000 mm.
Block size: Commonly is 1000 × 1000 × 86 mm.
●
●
●
●
●
●
●
22. 21E-mail: info@pvccoolingfill.com Web: http://www.pvccoolingfill.com
Cooling Tower Fills
Feature
Large wetted perimeter.
Small hydraulic radius.
Corrosion and rust resistance.
Chemical stability.
Temperature resistance.
High purifying performance.
High treating capacity.
●
●
●
●
●
●
●
Physical treatment instead of chemicals.
Cost saving and economical.
Non-toxic and will not pollute the water or surrounding environments.
COD removal rate up to 60% – 70%.
Color removal rate up to 60% – 90%.
●
●
●
●
●
Types
Corrugated plate for lamella clarifier Inclined tube settler for lamella clarifier
Inclined tube settlers are used
in the lamella clarifier
Inclined tube settler is used to purify
waters in water treatment applications
Application
23. Address: Zhaohui Street Fuqiang Road, Zaoqiang
FRP Industry Zone Hebei 053100
Mobile: +86-13931808425 / +86-15713184658
E-mail: info@pvccoolingfill.com
Web: http://www.pvccoolingfill.com
Cooling Tower Parts