1. Chidambaram. S
S/O K.Subramaniyam
153, Kongu Nagar,
Perundurai, Erode-Dist.,
TamilNadu-638052.
Phone No: +91 9965584334.
Passport No: J3133673
E mail: chidambaram.prod@gmail.com
OBJECTIVE
To become a professional with sound practical knowledge and team building potential
and contribute my skills to the betterment of the firm I work for.
EXPERIENCE
1. Company Name: Rina India Pvt. Ltd., Mumbai
Designation: Inspection Engineer – QA/QC
Period: Since August’14
MAJOR PROJECTS HANDLED
• Process piping inspection Carried out of Rajasthan Northern Development Project at
Mangala Processing Terminal for M/S.Cairn India Ltd., Barmer, Rajasthan.
• Enhance Oil Recovery (EOR) Project at M/S.Cairn India Ltd., Barmer, Rajasthan.
ACTIVITES INVOLVED
• Review and understand the project specification / technical requirements & Drawings.
• Verification of materials, materials receiving inspection prior to release for fabrication
and installation.
• Review of client work method statement and QC procedure.
• Review the WPS, PQR and conducted WQT to qualify the welders.
• Witnessing the pipe fit ups & Weld visual at fabrication shop and site as per project
specification.
• Witnessing well pad modification activities as well as new well connection to the header
lines as per project specification / approved drawings.
• During Plant/Well pad shutdown witnessing the Tie in spool erection (Golden Joints) to
the live lines.
• RT film interpretation and witnessing the NDE tests.
• Witnessing PMI test on materials & welded joints.
• Review the PWHT charts and witnessing the Hardness test.
• Inspecting the structural fabrication and erection of the pipe racks and pipe supports as
per approved drawing/Code of construction.
• Raise the Technical Queries to the contractor/execution team as per site condition.
• Validity verification of calibrated measuring instruments, welding Machines, Electrode
baking ovens, Pressure Gauges
• To conduct line walk down and prepared punch list & classified the punch points and to
release the line for hydro test.
• Witnessing the hydro test as per project specification.
• Raising the NCR for the concern department who’s going against the approved
procedure/technical requirements and closing the NCR after completion of corrective
action which they are taken.
• Review and approve the test packs after completion of all site activities.
• Perform routine surveillance at contractor work site to inspect the welding consumables,
working tool status, welding parameters & check the Pre heat (If necessary).
• To conduct the toolbox talk at contractor work place and to make their welders
understand about WPS and review their previous day production reports.
2. 2. Company Name: Bureau Veritas India Pvt. Ltd., Chennai
Designation: Field Inspector – QA/QC
Period: Since April’12 to July’14
MAJOR PROJECTS HANDLED
• Process piping inspection Carried out of Effluent Treatment Plant (ETP) capacity of
1500 m³/hr for M/S. VA Tech Wabag at IOCL Paradip Refinery, Odhissa.
• Successfully completed the shop inspection of 320 KM of LSAW pipe for M/S. SCOP
(State Company of Oil Projects, IRAQ) as per API 5L at Jindal Saw Ltd., Gujarat.
ACTIVITES INVOLVED
In Project site
• Review the contract specification / technical requirements & Drawings.
• Review the WPS, PQR and witnessing WQT for Welders Qualification.
• Check the fit ups & weld visual of piping as per ITP/codes and approved isometric
drawings.
• Check the orientation of pipe fittings during erection at site as per approved isometric
drawings.
• Piping material identification as per isometric drawing.
• Coordinate with site quality person and give necessary feedback to client.
• Offering welds to NDT as per client approved procedure/project specification.
• Witnessing NDE inspection of welds and RT films interpretation.
• Review the PWHT chart & Hardness check as per project specification.
• Carry out the line walk down and preparing punch points and to issue the mechanical
clearance for loops to be hydro tested.
• Witnessing of hydro test and approve the final test packs.
• To prepared the Weekly/Monthly progress report to the client/End user.
In Pipe mill Industries and Shop floor
• Raw material inspection-Review of test certificates with relevant codes/standards and
Purchase Order.
• Witnessing of Procedure (WPS) & Performance (WPQ) Qualification as per ASME
Section.
• Welding parameter Monitoring & weld visual inspection of LSAW pipes.
• Review of radiographic films as per code of construction.
• Witnessing of pressure testing of pipes (Hydro test) as per code/technical specification.
• Witnessing of destructive tests for pipe lots as per API 5L/Customer requirements.
• Dimensional & Final inspection of welded pipes with approved QAP and test plans.
• Raising the NCR for the concern department who’s going against the QAP/ITP.
• Witnessing of 3.2 material test certification.
• Witnessing of PMI Test.
• Inspection carried out steel structures as per AWS D 1.1
• Inspection of structural items like columns, beams, Frames.
• Expediting with vendors and providing Updated expedition reports.
Company Name: SGS India Pvt. Ltd, Ahmedabad
Designation: Inspection Engineer – QA/QC
Period: July’09 to March’12
MAJOR PROJECTS HANDLED
• Successfully completed the shop inspection of 90 KM of HSAW pipe for M/S. GSWB
(Gujarat State Water Board), Surat as per IS 3589:2001 at PSL Pipes Ltd., Gujarat.
• Ductile iron pipes (Produced by Centrifugal Casting) inspection as per IS, ISO and BSEN
standards in Jindal Saw Ltd. & Electrotherm India Ltd., Gujarat.
3. • Successfully completed the 21MW (1.5MWx14) wind farm project at Palladam,
Tamilnadu for M/s.Hindustan Zinc Ltd.
ACTIVITES INVOLVED
In Pipe mill Industries & Ductile Iron Pipe Manufacturing
• Raw material inspection - Review of Test certificates with respect to Standards & P.O
• Review the WPS,PQR and witnessing the WQT.
• Witnessed the destructive tests as per approved ITP/Project specification.
• RT film interpretation.
• Witnessing of hydro test as per project specification.
• Final and Dimensional inspection as per standard and QAP/ITP.
• Perform routine inspection, monitoring & assurance of production activities (Casting,
Cement Lining) in accordance with the Projects/Client specifications, ITP & Quality
Plans.
• Stage inspection is followed as per quality assurance plan.
• Inspecting the coating thickness of galvanizing & bituminous coating as per codes/Client
specifications.
• Review and comment upon manufacture daily inspection records
In Wind Farm Project
• Witnessing the torque of wind Turbine by using hydraulic and manual torque wrenches.
• Testing the sensor operations in rotor and nacelle, rotor break operation, Nacelle yawing,
Blade pitching and angel setting.
• To check the laser alignment test for non-drive end of gear box to generator’s drive end
during pre-commissioning activities for wind turbine generator.
• Review and approve the mechanical erection protocol.
CERTIFICATION COURSE
ASNT (American Society for Nondestructive Testing) NDT Level-II Qualified
Ultrasonic Testing (UT), Radiographic testing (RT), Magnetic Particle Testing (MPT),
Liquid Penetrant testing (LPT).
ACADAMIC RECORDS
• B.E (Production) From Government College of Technology, Coimbatore in 2009 and
obtained the aggregate of 66.18%.
• HSC from Private in 2005 and obtained the Percentage of 90.08%.
• SSLC from Govt. Boys Hr. Sec. School, Perundurai and Obtained the Percentage of 88.40%.
Personal Details:
Father’s name
Marital Status
:
:
K. Subramanian
Single
Sex : Male
Date of Birth : 02.06.1987
Nationality : Indian
Mother Tongue : Tamil
Languages known : Tamil, English & Hindi (Speaking only).
I hereby declare that all details and particulars furnished above are correct to the best of my
knowledge.