For more Full product Details:www.examsboost.com
Our workable study material for exam meets the exact and accurate exam questions and answers. So that’s why ExamsBoost is popular in the field of IT Certification Exams material providers.Please visit site: www.examsboost.com/
Good Stuff Happens in 1:1 Meetings: Why you need them and how to do them well
Best Network appliance NS0-157 Free Latest Exam Questions
1. Network Appliance
Exam Code: NS0-157
Exam Name: NetApp Certified Data Administrator,
Clustered Data ONTAP
http://www.examsboost.com/test/NS0-157/
ExamsBoost
Boost up Your Certification Score
Product Version =Demo
Up to Date products, reliable and verified.
Questions and Answers in PDF Format.
2. EXAMSBOOST2 | P a g e
http://www.examsboost.com/test/NS0-157/
Question: 1
When creating a data aggregate, what is the default minimum number of disks for RAID4 and RAID-
DP?
A. 5 for RAID4 and 9 for RAID-DP
B. 4 for RAID4 and 7 for RAID-DP
C. 3 for RAID4 and 5 for RAID-DP
D. 2 for RAID4 and 3 for RAID-DP
Answer: D
Explanation: If a root volume exists as a traditional volume, it can be a stand-alone RAID4 or RAID-DP
volume. RAID4 requires a minimum of two disks and can protect against single-disk failures. RAID-
DP, the default RAID type, requires a minimum of three disks and can protect against double-disk
failures. Using RAID-DP for the root aggregate is recommended.
Reference: https://library.netapp.com/ecmdocs/ECMP1196986/html/GUID-306BB9AE-99CF-4C98-
AB5F-C23A77FA4B6A.html
Question: 2
What are the two valid settings for fractional reserve? (Choose two.)
A. 100%
B. 20%
C. 0%
D. 50%
Answer: A, C
Explanation: The fractional reserve setting is expressed as a percentage; the only valid values are 0
and 100 percent. You use the vol options command to set fractional reserve.
Reference: https://library.netapp.com/ecmdocs/ECMP1368845/html/GUID-596042AF-8E9C-4187-
969C-633DFDD5A936.html
Question: 3
How many disks reside in a DS4246 shelf?
A. 46
B. 42
C. 14
D. 24
Answer: D
Explanation:
3. EXAMSBOOST3 | P a g e
http://www.examsboost.com/test/NS0-157/
Reference: http://www.netapp.com/uk/products/storage-systems/disk-shelves-and-storage-
media/disk-shelves-tech-specs.aspx(See the Table).
Question: 4
Which two NFS versions are supported on clustered Data ONTAP 8.3? (Choose two.)
A. NFSv1
B. NFSv2
C. NFSv3
D. NFSv4
Answer: C, D
Explanation: Configure clustered Data ONTAP 8.3 for NFSv3, NFSv4, and NFSv4.1, including parallel
NFS (pNFS)
Question: 5
A customer wants to use a UTA2 PCIe card in a new FAS8000 system.
Which three steps must be completed before the customer is able to use the ports for Fc access to
an FCP switch? (Choose three.)
A. Use the system hardware unified-connect modify command to change the personality from
initiator to target.
B. Verify the WWPN of the UTA2 so that these can be used in the igroup to map the LUNs for host
access.
C. Verify that the correct SFP+ is installed for FC.
D. Verify the card’s hardware configuration by running the system hardware unified-connect show
command.
E. Verify that Data ONTAP iSCSI, GIFS, and NFS are licensed on the system.
Answer: A, C, D
Reference: https://library.netapp.com/ecmdocs/ECMP1368525/html/GUID-EC0DDAEE-1178-48EF-
B90D-0A7DF498F71B.html
Question: 6
Which two default SVM roles are available when an SVM is created? (Choose two.)
A.vsadmin-readonly
B. root
C.vsadmin
D. admin
Answer: A, C
4. EXAMSBOOST4 | P a g e
http://www.examsboost.com/test/NS0-157/
Explanation:
Reference: https://library.netapp.com/ecmdocs/ECMP1368701/html/GUID-FFE11F8C-490B-4D6D-
A18E-3488275029C7.html(See the table 1st point and last point).
Question: 7
In the storage failover command, what does the bypass-optimization option do?
A. It takes over the partner node without performing aggregate relocation.
B. It migrates all logical interfaces during takeover.
C. It takes over without migrating all logical interfaces.
D. It takes over the partner node performing aggregate relocation.
Answer: A
Explanation:
Take over the partner node without performing
aggregate relocation
storage failover takeover -bypass-
optimization true
Reference: https://library.netapp.com/ecmdocs/ECMP1367947/html/GUID-4B814447-521D-43B7-
846D-AB4EF86A25A1.html
Question: 8
Which type of upgrade is supported from a single-node FAS2552 to a dual-node cluster with
clustered Data ONTAP 8.3 when all 10 GB ports are used for host access?
A. a disruptive upgrade from a single-node cluster to a dual-node HA cluster
B. a non-disruptive upgrade of a single-node cluster into a dual-node HA cluster
C. a single-node cluster upgraded by migration of data to another single-node cluster
D. a disruptive single-node cluster upgraded to a dual-node HA cluster by adding 10 Gb Ethernet
cards
Answer: D
Question: 9
Which two solutions are valid for clustered Data ONTAP MetroCluster? (Choose two.)
A. FAS3200 series controllers
B. FAS2500 series controller
C. four nodes at each site
D. two nodes at each site
Answer: A, D
Question: 10
5. EXAMSBOOST5 | P a g e
http://www.examsboost.com/test/NS0-157/
Which type of connectivity is supported when connecting third-party arrays through FlexArray
Virtualization for back-end storage to a NetApp cluster?
A. iSCSI
B. SAS
C. FC
D. Infiniband
Answer: C
Explanation:
Reference:
On the back end, FlexArray attaches to your existing storage arrays via Fibre Channel and provides a
virtualization layer between the storage array and the hosts
Question: 11
You have multiple volumes that are exported to a group of hosts within your environment. A new
host needs access to the volumes.
Which two actions accomplish this task? (Choose two.)
A. Mount the new exports from the host.
B. Create a new SVM.
C. Create a rule in the export policy on the SVM.
D. Create a new data LIF on the SVM.
Answer: C, D
Question: 12
A customer wants to use jumbo frames on an interface group called a0a. Interface group a0a
contains ports e0c and e0d. Additionally, the customer is using VLAN tagging for VLANs 510 and 520.
VLAN 510 will use jumbo frames but VLAN 520 will not. When the customer tries to enable jumbo
frames on a0a-510 the command fails.
What caused the failure?
A. The MTU size must be set on the broadcast domain to which the ports belong.
B. The LIF corresponding with VLAN 510 is not configured for jumbo frames.
C. Ports e0c and e0d have conflicting MTU sizes configured.
D. Jumbo frames must be enabled from the advanced privilege set.
Answer: A
Question: 13
6. EXAMSBOOST6 | P a g e
http://www.examsboost.com/test/NS0-157/
You change the volume junction-path of vol1 from /vol/vol1 to /vol1. NFS clients are unable to
connect to the new path/vol1.
Which mirrors need to be updated to solve this problem?
A. TDP mirrors of the SVM root volume.
B. XDP mirrors of the SVM root volume
C. DP mirrors of the SVM root volume
D. LS mirrors of the SVM root volume
Answer: D
Question: 14
You just added a vSphere host to your environment that needs access to the existing NFS datasrtore.
The applicable export policy is named VMW, and each host’s IP address has been given access.
What should you do to grant the new host access to the NFS datastore?
A. Create a new volume.
B. Create a new rule under the VMW export policy.
C. Create a new SVM.
D. Create a new export policy for the new host.
Answer: A
Question: 15
A NetApp cluster is connected to two network switches for resiliency. One of the network switches
loses power. Most LIFs on the cluster automatically recover from the switch failure to and are
reachable through the network. One LIF used for CIFS access is not reachable through the network
until power is restored to the failed switch.
Which two areas should be investigated to determine the problem? (Choose two.)
A. The protocols allowed on the LIFs.
B. The LIFs failover-group configuration.
C. The LIFs home port.
D. The broadcast domain’s member ports.
Answer: B, C
Question: 16
An administrator is attempting to add two FAS8020 nodes to an existing cluster of eight FAS2552
nodes. They are receiving an error when attempting to join the new nodes.
What is causing this error?
A. The cluster switch connections have been cabled incorrectly.
B. The disk shelves on one of the new nodes are displaying an error.
C. The maximum number of nodes is already in the cluster.
7. EXAMSBOOST7 | P a g e
http://www.examsboost.com/test/NS0-157/
D. The new nodes are running a newer version of clustered Data ONTAP.
Answer: D
Question: 17
A customer has an aggregate, aggr1_01 with three RAID groups: rg0, rg1, and rg2. Each RAID group
has 15 disks, and the aggregate’s maximum RAID group size is set to 18 disks. The customer adds
three additional disks to the aggregate using the following command:
storage aggregate add-disks –aggregate aggr1_01 –diskcount 3
How are the RAID groups affected by this command?
A. The disks are added to a new RAID group rg3.
B. Each RAID group receives one additional disk.
C. The three disks are added to RAID group rg2.
D. The three disks are added to RAID group rg0.
Answer: B
Question: 18
A customer has a 1000 GB volume that is at 25% capacity and has no existing Snapshot copies. The
customer creates a Snapshot copy of the volume, creates a new 250 GB file, and deletes an existing
100 GB file.
How much space is free in the volume?
A. 350 GB
B. 400 GB
C. 500 GB
D.600 GB
Answer: C
Question: 19
A user is reporting trouble using a SVM management LIF. You have verified host configuration,
network connectivity, and that the LIF responds to pings.
What should you do to continue troubleshooting this problem?
A. Ensure the SVM management LIF’s failover policy is correct.
B. Ensure the SVM management LIF’s administrative status is up.
C. Ensure the SVM management LIF is on its home port.
D. Ensure the SVM management LIF’s firewall policy is set to management.
Answer: A
8. EXAMSBOOST8 | P a g e
http://www.examsboost.com/test/NS0-157/
Explanation:
Reference: You must have prepared the SVM networking for a major upgrade by creating the
necessary SVM management LIFs, failover groups, and routes.
Reference:https://library.netapp.com/ecmdocs/ECMP1636041/html/GUID-5B0E96CF-78F8-40B9-
A62D-C5A6E62A53D7.html
Question: 20
You notice your indirect I/O performance between nodes in your 4-node cluster is slowing down
from prior week. Each node has two 10 GB connections to the cluster interconnect, one to each
switch. You are using four out of 12 available ports on each cluster interconnect switch. Your cluster
network utilization is over 80%.
What should you do to increase cluster interconnect performance?
A. Change the SFP+ from 10 Gb to 16 Gb on each node and switch.
B. Add two more cluster interconnect connections per node.
C. Add additional ISLs between the two cluster interconnect switches.
D. Change the cable from TwinAx to optical with SFP+ for better throughput.
Answer: B
9. EXAMSBOOST9 | P a g e
http://www.examsboost.com/test/NS0-157/
Thank You for Trying Our Product
Click the Link Below To Get Full Version
http://www.examsboost.com/test/NS0-157/
WE ACCEPT
FEATURES
90 Days Free Updates
Money Back Pass Guarantee
Instant Download or Email Attachment
24/7 Live Chat Support
PDF file could be used at any Platform
50,000 Happy Customer