This API-653 inspection report summarizes the findings of an inspection of a 210,000-gallon aboveground storage tank. The inspection found that the tank's mechanical integrity does not meet API-653 requirements due to issues with shell weld alignment, penetrations without reinforcing plates, and shell inserts with non-rounded corners. Ultrasonic thickness readings were taken and pitting was noted that did not exceed allowable limits. The roof could not be fully inspected due to corrosion on the access ladder. Recommendations included repairs to the shell, floor, and coating as well as further inspections of welds.