Submit Search
Upload
Analysis and design of high-rise diagrid structures
•
0 likes
•
43 views
AI-enhanced title
IRJET Journal
Follow
https://www.irjet.net/archives/V9/i6/IRJET-V9I685.pdf
Read less
Read more
Engineering
Report
Share
Report
Share
1 of 5
Download now
Download to read offline
Recommended
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET Journal
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
IRJET Journal
DIA-Grid Structures
DIA-Grid Structures
IRJET Journal
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET Journal
“Analysis of Multi Storied Diagrid Structure using ETABS Software”
“Analysis of Multi Storied Diagrid Structure using ETABS Software”
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
IRJET Journal
Recommended
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET Journal
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
IRJET Journal
DIA-Grid Structures
DIA-Grid Structures
IRJET Journal
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET Journal
“Analysis of Multi Storied Diagrid Structure using ETABS Software”
“Analysis of Multi Storied Diagrid Structure using ETABS Software”
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
IRJET Journal
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
IRJET Journal
IRJET- A Performance Study of (G+20) RCC Structure using Framed Bundled B...
IRJET- A Performance Study of (G+20) RCC Structure using Framed Bundled B...
IRJET Journal
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
IRJET Journal
A Review on Seismic Analysis of Irregular Plan of Diagrid Structure on Slopin...
A Review on Seismic Analysis of Irregular Plan of Diagrid Structure on Slopin...
IRJET Journal
REVIEW ON BEHAVIOUR OF DIAGRID STRUCTURAL SYSTEM IN HIGH-RISE BUILDING
REVIEW ON BEHAVIOUR OF DIAGRID STRUCTURAL SYSTEM IN HIGH-RISE BUILDING
Journal For Research
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET Journal
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
IAEME Publication
Study on Behavior of Tubular Diagrid Structures During Seismic Excitation
Study on Behavior of Tubular Diagrid Structures During Seismic Excitation
IRJET Journal
IRJET- Comparative Analysis of RCC Structure and Tube-in-Tube Structure
IRJET- Comparative Analysis of RCC Structure and Tube-in-Tube Structure
IRJET Journal
IRJET-Analytical Study on Horizontal Irregularities in RCC Structures with La...
IRJET-Analytical Study on Horizontal Irregularities in RCC Structures with La...
IRJET Journal
Analysis of diagrid structure in comparison with exterior braced frame structure
Analysis of diagrid structure in comparison with exterior braced frame structure
eSAT Journals
IRJET- Diagrid Structural System for Tall Buildings: State of the Art Review
IRJET- Diagrid Structural System for Tall Buildings: State of the Art Review
IRJET Journal
IRJET- Analysis of G+45 Bundled Tube Structure using Different Bracing System...
IRJET- Analysis of G+45 Bundled Tube Structure using Different Bracing System...
IRJET Journal
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET Journal
Comparative Seismic Analysis of G+20 RC Framed Structure Building for Maximum...
Comparative Seismic Analysis of G+20 RC Framed Structure Building for Maximum...
IRJET Journal
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET Journal
Analyzing Utility of Component Elements of Outrigger System
Analyzing Utility of Component Elements of Outrigger System
IRJET Journal
IJRET20140304067
IJRET20140304067
Nishith Panchal
Diagrid structural system strategies to reduce lateral forces on high rise bu...
Diagrid structural system strategies to reduce lateral forces on high rise bu...
eSAT Publishing House
SEISMIC ANALYSIS OF TRANSFER SLAB STRUCTURE WITH DIFFERENT GEOMETRY
SEISMIC ANALYSIS OF TRANSFER SLAB STRUCTURE WITH DIFFERENT GEOMETRY
IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
More Related Content
Similar to Analysis and design of high-rise diagrid structures
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
IRJET Journal
IRJET- A Performance Study of (G+20) RCC Structure using Framed Bundled B...
IRJET- A Performance Study of (G+20) RCC Structure using Framed Bundled B...
IRJET Journal
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
IRJET Journal
A Review on Seismic Analysis of Irregular Plan of Diagrid Structure on Slopin...
A Review on Seismic Analysis of Irregular Plan of Diagrid Structure on Slopin...
IRJET Journal
REVIEW ON BEHAVIOUR OF DIAGRID STRUCTURAL SYSTEM IN HIGH-RISE BUILDING
REVIEW ON BEHAVIOUR OF DIAGRID STRUCTURAL SYSTEM IN HIGH-RISE BUILDING
Journal For Research
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET Journal
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
IAEME Publication
Study on Behavior of Tubular Diagrid Structures During Seismic Excitation
Study on Behavior of Tubular Diagrid Structures During Seismic Excitation
IRJET Journal
IRJET- Comparative Analysis of RCC Structure and Tube-in-Tube Structure
IRJET- Comparative Analysis of RCC Structure and Tube-in-Tube Structure
IRJET Journal
IRJET-Analytical Study on Horizontal Irregularities in RCC Structures with La...
IRJET-Analytical Study on Horizontal Irregularities in RCC Structures with La...
IRJET Journal
Analysis of diagrid structure in comparison with exterior braced frame structure
Analysis of diagrid structure in comparison with exterior braced frame structure
eSAT Journals
IRJET- Diagrid Structural System for Tall Buildings: State of the Art Review
IRJET- Diagrid Structural System for Tall Buildings: State of the Art Review
IRJET Journal
IRJET- Analysis of G+45 Bundled Tube Structure using Different Bracing System...
IRJET- Analysis of G+45 Bundled Tube Structure using Different Bracing System...
IRJET Journal
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET Journal
Comparative Seismic Analysis of G+20 RC Framed Structure Building for Maximum...
Comparative Seismic Analysis of G+20 RC Framed Structure Building for Maximum...
IRJET Journal
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET Journal
Analyzing Utility of Component Elements of Outrigger System
Analyzing Utility of Component Elements of Outrigger System
IRJET Journal
IJRET20140304067
IJRET20140304067
Nishith Panchal
Diagrid structural system strategies to reduce lateral forces on high rise bu...
Diagrid structural system strategies to reduce lateral forces on high rise bu...
eSAT Publishing House
SEISMIC ANALYSIS OF TRANSFER SLAB STRUCTURE WITH DIFFERENT GEOMETRY
SEISMIC ANALYSIS OF TRANSFER SLAB STRUCTURE WITH DIFFERENT GEOMETRY
IRJET Journal
Similar to Analysis and design of high-rise diagrid structures
(20)
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
IRJET- A Performance Study of (G+20) RCC Structure using Framed Bundled B...
IRJET- A Performance Study of (G+20) RCC Structure using Framed Bundled B...
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
A Review on Seismic Analysis of Irregular Plan of Diagrid Structure on Slopin...
A Review on Seismic Analysis of Irregular Plan of Diagrid Structure on Slopin...
REVIEW ON BEHAVIOUR OF DIAGRID STRUCTURAL SYSTEM IN HIGH-RISE BUILDING
REVIEW ON BEHAVIOUR OF DIAGRID STRUCTURAL SYSTEM IN HIGH-RISE BUILDING
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
ISEISMIC PERFORMANCE OF RC FRAMED BUILDINGS UNDER LINEAR DYNAMIC ANALYSISjcie...
Study on Behavior of Tubular Diagrid Structures During Seismic Excitation
Study on Behavior of Tubular Diagrid Structures During Seismic Excitation
IRJET- Comparative Analysis of RCC Structure and Tube-in-Tube Structure
IRJET- Comparative Analysis of RCC Structure and Tube-in-Tube Structure
IRJET-Analytical Study on Horizontal Irregularities in RCC Structures with La...
IRJET-Analytical Study on Horizontal Irregularities in RCC Structures with La...
Analysis of diagrid structure in comparison with exterior braced frame structure
Analysis of diagrid structure in comparison with exterior braced frame structure
IRJET- Diagrid Structural System for Tall Buildings: State of the Art Review
IRJET- Diagrid Structural System for Tall Buildings: State of the Art Review
IRJET- Analysis of G+45 Bundled Tube Structure using Different Bracing System...
IRJET- Analysis of G+45 Bundled Tube Structure using Different Bracing System...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
IRJET- Multi Cornered Thin Wall Sections for Crashworthiness and Occupant Pro...
Comparative Seismic Analysis of G+20 RC Framed Structure Building for Maximum...
Comparative Seismic Analysis of G+20 RC Framed Structure Building for Maximum...
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET- Parametric Study on Multistoried Diagrid Structure
Analyzing Utility of Component Elements of Outrigger System
Analyzing Utility of Component Elements of Outrigger System
IJRET20140304067
IJRET20140304067
Diagrid structural system strategies to reduce lateral forces on high rise bu...
Diagrid structural system strategies to reduce lateral forces on high rise bu...
SEISMIC ANALYSIS OF TRANSFER SLAB STRUCTURE WITH DIFFERENT GEOMETRY
SEISMIC ANALYSIS OF TRANSFER SLAB STRUCTURE WITH DIFFERENT GEOMETRY
More from IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
IRJET Journal
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
IRJET Journal
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
IRJET Journal
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
IRJET Journal
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
IRJET Journal
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
IRJET Journal
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
IRJET Journal
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
IRJET Journal
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
IRJET Journal
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
IRJET Journal
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
IRJET Journal
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
IRJET Journal
React based fullstack edtech web application
React based fullstack edtech web application
IRJET Journal
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
IRJET Journal
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
IRJET Journal
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
IRJET Journal
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
IRJET Journal
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
IRJET Journal
More from IRJET Journal
(20)
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
React based fullstack edtech web application
React based fullstack edtech web application
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Recently uploaded
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Christo Ananth
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
SIVASHANKAR N
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
upamatechverse
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur High Profile
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
ranjana rawat
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
SIVASHANKAR N
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
9953056974 Low Rate Call Girls In Saket, Delhi NCR
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
NikhilNagaraju
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
KurinjimalarL3
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Low Rate Call Girls In Saket, Delhi NCR
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
wendy cai
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
9953056974 Low Rate Call Girls In Saket, Delhi NCR
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
slot gacor bisa pakai pulsa
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
upamatechverse
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
João Esperancinha
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Dr.Costas Sachpazis
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
Suhani Kapoor
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
Suhani Kapoor
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
ranjana rawat
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
Soham Mondal
Recently uploaded
(20)
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
Introduction to IEEE STANDARDS and its different types.pptx
Introduction to IEEE STANDARDS and its different types.pptx
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
(MEERA) Dapodi Call Girls Just Call 7001035870 [ Cash on Delivery ] Pune Escorts
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
main PPT.pptx of girls hostel security using rfid
main PPT.pptx of girls hostel security using rfid
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
DJARUM4D - SLOT GACOR ONLINE | SLOT DEMO ONLINE
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Decoding Kotlin - Your guide to solving the mysterious in Kotlin.pptx
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANVI) Koregaon Park Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
OSVC_Meta-Data based Simulation Automation to overcome Verification Challenge...
Analysis and design of high-rise diagrid structures
1.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 06 | June 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 515 ANALYSIS AND DESIGN OF HIGH-RISE DIAGRID STRUCTURES Swagat Dattatraya Aher1, Prof.Vishwajit Kadlag2 1PG Scholar,Department of Civil Engineering,Dr.D.Y.Patil School of Engineering and Technolgy, Charholi Bk, Via Lohegaon, Pune, Maharastra, India 2Associate Professor, Department of Civil Engineering, Dr.D.Y.Patil School of Engineering and Technolgy, Charholi Bk, Via Lohegaon, Pune, Maharastra, India ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - As the world's population grows, so does the cost of accessible land. The lateral loads become more important than the gravitational loads as the building's height rises. Wind load and earthquake load are two forms of lateral loads that can be applied to high-rise buildings. Different forms of lateral load resisting structures used in high-rise buildings include shear walls, rigid framed structures, brace tubes, wall frames, outrigger systems, and diagrid systems. For lateral load resistance, thediagridstructuralsystem isan efficient and effective structural system. Diagrid structure isa type of exterior structural system in which all external columns are replaced by a sequence of triangular shaped diagonal grids, and inside columnsaresolelymeanttosupport gravity loads. Two forms of 48 story structures in seismic zone III are studied in this study: rectangular &L-shape. Thetotalheightof all the structures is 168 meters. There are four diagrid modules in the seismic zone. In the diagrid construction, two, four, six, and eight modules have been employed. E-TABS is used to analyses and simulate diagrid structure. IS 800:007 is used to design all structural members. For earthquake analysis, IS 1893 part1- 2016 is utilized, and for wind load analysis, IS 875 part3- 2015 is employed. For dynamic analysis, the response spectrum approach is used. The maximum storey displacementandmaximumstoreydriftof all the study findings are compared, and the ideal diagrid angle for all modules is calculated. Key Words: Diagrid structure, Storey displacement, Storey drift, Optimum diagrid angle 1. INTRODUCTION Rapid population expansion and high land costs have a significant influence on the construction sector, which leads to an upward trend in building construction.However,when building heights rise, lateral load resisting systems become more critical than gravity load resisting structural systems. To withstand the lateral stresses. Rigid frame, shear wall, wall-frame, utilised braced tube system, outrigger system, and tubular system are some of the most prevalent systems. Because of the structural efficiency and aesthetic possibilities given by the system's distinctive geometric design, the diagonal grid structural system has recently become popular for tall structures. Rapid population expansion and high land costs have a significantinfluence on the construction sector, which leads to an upward trend in building construction. However, when building heights rise, lateral load resisting systems become more critical than gravity load resisting structural systems. To be able to tolerate lateral strains. Some of the most common systems include rigid frame, shear wall,wall-frame,employedbraced tube system, outrigger system, and tubular system. The diagonal grid structural system has lately become popular for tall structures due to its structural efficiency and aesthetic possibilities provided by the system's distinctive geometric form. Because of the layout and efficiency of a diagrid system, the number of structural elements required on the outside side of buildings is reduced, resulting in less blockage to the outside view. The structural efficiency of the diagrid system also aids in the avoidance of interior and corner columns, allowing for greatfloordesignfreedom.The most recent high-rise building system, which has now become the most popular The "Diagonal Grid System," also known as the "Diagrid system," is popular among today's designers. The Diagrid system is made up of multiple diagonal components that join to produce a triangulated or grid-shaped design. The name "diagrid" is derived from the phrases "diagonal" and "grid." A diagrid structure is a sortof structural system that consists of diagonal grids connected by horizontal rings to provide a beautiful and redundant structure that is particularly useful for high-rise structures. Due to its triangulated configuration, diagrid structures differ from braced frame systems in that diagonals as key structural components contribute insupportinggravityload as well as lateral load, obviating the requirement forvertical columns. A diagrid system's column-free structure has various advantages, including great architectural freedom, elegance, and huge day illumination due to its small outside surface. Because of its structural efficiency, the diagrid system has recently been used on numerous tall steel structures. 2. Objective of Study I. To assess the performance of a high-rise building equipped with a diagrid system. II. To do static analysis, response spectrum analysis, and wind analysis in terms of story displacement and drift
2.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 06 | June 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 516 III. Determine the diagrid system's optimal diagrid angle. 3. Geometric parameters of the building models Structural parameter Steel structure Shapes of building rectangular and L- shape Number of stories 48 Size of plan a). for rectangular shape 48m x 64m b). for L-shape shape 48m x 48m Spacing between bays 4m Spacing between diagrid along perimeter 8m Height of each storey 3.5m Number storey per module 2, 4, 6, & 8 storey Grade of structural steel (Fy) Fe 500 Grade of concrete (Fck) M40 3.1 Comparative analysis Case-I : Comparison between each module for rectangular and L-shape shape of structure. 2-storey module 4-storey module 6-storey module 8-storey module Case-II: Combination all storey modules rectangular and L- shape of structure. 2-storey, 4-storey, 6-storey and 8 storey 4. Research Methodology The analysis of a 48-story diagrid structure withrectangular and L-shaped building is offered in this work. As per Indian Standard, lateral forces owing to earthquakes and wind effects are taken into account. The structure was analyzed using IS 1893:2016 and IS800:2007.TheETABSprogramme is used for modeling and analysis of diagrid systems. Earthquake loads are subjected to response spectrum analysis. The beams and columns are treated as flexural components for linear static and dynamic analysis. The major goal of this study is to investigatethebehaviorofhigh- rise buildings with Diagrid systems of various angles for rectangular and L-shape structures in seismic zone III, as well as to determine the best diagrid angle using static, dynamic, and wind analysis. In first phase, modeling of 48 storey high rise buildings with Diagrid systems by defining material and section properties & having same height with different diagrid angles which is done by using ETABS software. In second phase, define several sorts of loads and their combinations on the rectangular shapeofthestructureinthe second phase. Define the functions necessary for the response spectrum in dynamic analysis. Finally, using the findings of the study, verify the behavior of a rectangular shape structure with Diagrid systems of the same height and different angle in seismic zone III. In third phase, define several sorts of loads and their combinations on additional L-shape structures for dynamic analysis in the third phase. Define the functions that will be used to create the response spectrum. Finally, using the findings of the study, examine the behavior of the L-shape of structure with Diagrid systems with the same height and different angle in seismic zone III. In fourth phase, The collecting and analyzing data on two forms of structures in the form of several parameterssuchas Storey shear and Storey Drift is the fourth phase. In the fifth step, evaluate all seismic zone-III factors to determine the best angle for rectangular and L-shaped structures, as well as combinations of 2, 4, 6, and 8-story modules. 5. Modeling and Analysis Fig -1: Plan of rectangular shape building model Figure 1 shows the typical planofrectangularshapebuilding models which are Considered for the study as shown in figure and spacing between each bay is 4 meters.
3.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 06 | June 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 517 Fig -2: Plan of L- shape building model The building is subjected to following Loads as per IS 875 (part 1 and 2)-2015: Dead load: 2 kN/m2 Live Load: 3 kN/m2 The following table shows that basic design consideration in seismic zone III. Table -1: Basic design consideration Fig -3: 3D rendered view of rectangular shape structure Fig -4: 3D rendered view of L- shape structure Story Beam Column [tube section] Diagrid [pipe section] 1-16 ISMB 550 750 X 750 X 50 750 X 25 17-32 ISMB 500 700 X 700 X 45 750X 25 33-48 ISMB 500 600 X 600 X 35 750 X25 Table -2: Section properties for rectangular & L-shape of building Number storeys per module Angle (Degree) 2 41.18 4 60.25 6 69.14 8 74.05 Table -3: Diagrid angle for rectangular & L- shape of building During the seismic zone III narrative module analysis, all load combinations are chosen as per IS 800. In ETABS, the load combinations shown in the table are selected using the default steel structure combination. Wind parameter details: (AS PER IS 875-2015) in zone III. Terrain category – 3 Structure class – C Risk coefficient – 1.06 Topography factor – 1 Importance factor- 1.30 Zone Zone factor Location of building Basic wind speed of city in m/s Soil type III 0.16 Pune 39 Hard(site type 1)
4.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 06 | June 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 518 6. Result and Discussion 1. Analysis Result and its Discussion for Rectangular shape of building in Seismic Zone III. Fig -5: Maximum storey displacement for all modules modules in rectangular shape structure The graphical representation of maximum storey displacement of 48 story rectangular building modules in zone III is shown in Figure: 5. In the 8 module diagrid, the maximum storey displacement is 193.48 mm. The greatest storey displacement with the least value is 166.2 mm, which is recorded for a four-story module. The minimum value of maximum story displacement is found to be between 60 degree and 70 degree. The maximum allowable storey displacement is 336 mm, When comparing eight module diagrid to four module and six modulediagrid,themaximum story displacement for four moduleandsix modulediagridis reduced by 14.09 % and 4.46 % respectively. The maximum storey drift of 48 story rectangular building modules in zone III is depictedgraphicallyinFigure:6.Thisis the graphical representation for wind load analysisbecause, when compared to seismic and response spectrum analysis, wind load analysis offers the highest values of tale drift in zone III. The maximum storey drift in the combo module is 0.001532m, which is greater. The smallest maximum storey drift value is 0.001176 m, which may be found in the four- story module diagrid. The maximum allowablestoreydriftis 0.014 m. Maximum story drift for all modules in zone III is observed to be within this limit. Maximum story drift for four module and six module diagrid is reduced by 23.24% and 15.68% when we compare with combination module diagrid which gives maximum value of drift in zone III. Fig -6: Maximum storey drift for all modules in rectangular shape structure 2. Analysis Result and its Discussion for L-shape ofbuilding in Seismic Zone III. Fig -7: Maximum storey displacement for all modules in L- shape structure The maximum storey displacement of 48 storey L-shaped building modules in zone III is depicted graphicallyinFigure 7. In 8 modules, the maximum storey displacement is 252.65mm. 194.35 is the smallest figure of maximum storey displacement mm, which may be seen in a four-story module. It has been discovered that the minimum value of maximum storey displacement ranges from 60 to 70degree. The highest allowable storey displacement is 336 mm, and all modules in zone III have maximum story displacements that are within the allowable limit. When we compare the maximum story displacementofeightmodulediagridtofour and six module diagrid, the maximum story displacement of four and six module diagrid is lowered by23.07% and15.44 % respectively.
5.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 06 | June 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 519 Fig -8: Maximum storey drift for all modules in L-shape structure The maximum storey drift of 48 storey L-shaped building modules in zone III is depicted graphically in Fig 8.In the 8 module diagrid, the maximum storey drift is 0.001885 m. The smallest maximum storey drift value is 0.001360 m, which may be found in The diagrid is a four-story module. The maximum allowable storey drift is 0.014 m, and maximum story drift for all modules in zone III is observed to be within this limit. When eight module diagrid is compared to four and six module diagrid, the maximum narrative drift for four and six module diagrid is lowered by 27.85 % and 17.34 % respectively. 7. Conclusion i).Wind load has the maximum story displacementandstory drift in rectangular and L-shaped buildings as compared to earthquake load. ii).8-storey diagrid module has the maximum story displacement and story drift in rectangular and L-shaped buildings. iii).Combination of all modules in rectangular building produces minimum value of maximum storey displacement and maximum storey drift than L-shape of structure. In the 60-70 degree range, maximum storey displacement and maximum storey drift decrease. iv). In comparison to 2-storey, 6-storey, and 8-storey modules, the 4 storey module in any form of building delivers less value of maximum storey displacement and maximum storey drift. REFERENCES (1). M. M. Ali and K. Moon. (2007). Structural developments in tall buildings: Currents trends and future prospects. Architectural Science Review, University of Sydney . (2). Berry Charnish and Terry McDonnell. (2008). The Bow: Unique diagrid structural systems for a sustainable tall building. CTBUH 2008 8th World Congress, Dubai. (3). K. S. Moon. (2011). Diagrid Structures for Complex- Shaped Tall Buildings. The 12th East AsiaPacific Conference on Structural Engineering and Construction. (4). K. Jani and Paresh V. Patel. (2013). Analysis and design of diagrid structural system for high rise steel buildings. Chemical, Civil and Mechanical Engineering Tracks of 3rd Nirma University International Conference on Engineering. (5) G.Milana, P. Olmati, K. Gkoumas and F. Bontempi.(2014). Sustainability concepts in the design of high-rise buildings: the case of diagrid systems. 3rd International Workshop on Design in Civil and Environmental Engineering. (6). F. M. Thomas, Binu M.IssacandJessymol George.(2015). Performance evaluation of tall buildings with steel diagrid system. 2nd International Conference on Science, Technology and Management. (7). Manthan Shah, Snehal V. Mevada and Vishal B. Patel. (2016). Comparative study of diagrid structures with conventional frame structures. International Journal of Engineering Research and Application. (8). Dr. Mohammad T Bhuiyan and Dr.RobertoLeon.(2016). Preliminary design of Diagrid tall building. IAJC-ISAM International Conference. (9). U. A. Nawale and D. N. Kakade. (2016). Analysis of diagrid structural system by ETABS International Advanced Research Journal in Science, Engineering and Technology. (10). Dr.Gopisiddappa, M.Divyashree, Sindhuja. (2017). Performance study of high rise building with diagrid system under dynamic loading. International Research Journal of Engineering andTechnology.riseconstruction.International Journal of Civil Engineering and Technology.
Download now