Submit Search
Upload
“Analysis of Multi Storied Diagrid Structure using ETABS Software”
•
0 likes
•
20 views
IRJET Journal
Follow
https://www.irjet.net/archives/V9/i5/IRJET-V9I5759.pdf
Read less
Read more
Engineering
Report
Share
Report
Share
1 of 6
Download now
Download to read offline
Recommended
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
IRJET Journal
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
IRJET Journal
ANALYSIS AND DESIGN OF HIGH-RISE DIAGRID STRUCTURES
ANALYSIS AND DESIGN OF HIGH-RISE DIAGRID STRUCTURES
IRJET Journal
DIA-Grid Structures
DIA-Grid Structures
IRJET Journal
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
IRJET Journal
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET Journal
Comparative study of Diagrid System with Conventional Framed Structure
Comparative study of Diagrid System with Conventional Framed Structure
IRJET Journal
Analysis Of Earthquake Resistant Structure By Base Isolation Method
Analysis Of Earthquake Resistant Structure By Base Isolation Method
IRJET Journal
Recommended
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
COMPARATIVE ANALYSIS OF DIAGRID STRUCTURE WITH VARIOUS INDIAN SEISMIC ZONE
IRJET Journal
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
A Review of Comparison between Frame Structure & Diagrid under Seismic & Wind...
IRJET Journal
ANALYSIS AND DESIGN OF HIGH-RISE DIAGRID STRUCTURES
ANALYSIS AND DESIGN OF HIGH-RISE DIAGRID STRUCTURES
IRJET Journal
DIA-Grid Structures
DIA-Grid Structures
IRJET Journal
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
Seismic Behaviour of Multistorey RC Frame with Shear wall and Octagrid Sructure
IRJET Journal
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET- Comparative Study of different Shapes of Diagrid Structure System with...
IRJET Journal
Comparative study of Diagrid System with Conventional Framed Structure
Comparative study of Diagrid System with Conventional Framed Structure
IRJET Journal
Analysis Of Earthquake Resistant Structure By Base Isolation Method
Analysis Of Earthquake Resistant Structure By Base Isolation Method
IRJET Journal
Seismic Analysis of I Shaped and Plus Shaped Building with and without damper
Seismic Analysis of I Shaped and Plus Shaped Building with and without damper
IRJET Journal
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
IRJET Journal
SEISMIC ANALYSIS OF G+7 RESIDENTIAL BUILDING WITH AND WITHOUT SHEAR WALL
SEISMIC ANALYSIS OF G+7 RESIDENTIAL BUILDING WITH AND WITHOUT SHEAR WALL
IRJET Journal
Comparative Analysis of Conventional Steel Structure with Diagrid Structures ...
Comparative Analysis of Conventional Steel Structure with Diagrid Structures ...
IRJET Journal
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET Journal
“A REVIEW PAPER ON BEHAVIOR OF GRIDSHELL STRUCTURE”
“A REVIEW PAPER ON BEHAVIOR OF GRIDSHELL STRUCTURE”
IRJET Journal
Performance Study of High Rise Building with Diagrid System Under Dynamic Loa...
Performance Study of High Rise Building with Diagrid System Under Dynamic Loa...
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Analysis of diagrid structure in comparison with exterior braced frame structure
Analysis of diagrid structure in comparison with exterior braced frame structure
eSAT Journals
Corelative Study of Regular and Mass-Irregular Multistorey Building
Corelative Study of Regular and Mass-Irregular Multistorey Building
IRJET Journal
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET Journal
“Analysis of a Multistorey Building with Grid slab in Different Seismic Zones...
“Analysis of a Multistorey Building with Grid slab in Different Seismic Zones...
IRJET Journal
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
IRJET Journal
Seismic Performance of Circular And Rectangular Column by Cyclic And Monotoni...
Seismic Performance of Circular And Rectangular Column by Cyclic And Monotoni...
IRJET Journal
OPTIMAL GRID GEOMETRY OF A DIAGRID STRUCTURE
OPTIMAL GRID GEOMETRY OF A DIAGRID STRUCTURE
IRJET Journal
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET Journal
Performance Analysis of the Tall Structure with Diagrid for Seismic Loading
Performance Analysis of the Tall Structure with Diagrid for Seismic Loading
IRJET Journal
Performance based design of Tall RC Structures considering Uncertainty in pla...
Performance based design of Tall RC Structures considering Uncertainty in pla...
IRJET Journal
IRJET- Design and Analysis of Concrete Diagrid Building and its Comparison wi...
IRJET- Design and Analysis of Concrete Diagrid Building and its Comparison wi...
IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
More Related Content
Similar to “Analysis of Multi Storied Diagrid Structure using ETABS Software”
Seismic Analysis of I Shaped and Plus Shaped Building with and without damper
Seismic Analysis of I Shaped and Plus Shaped Building with and without damper
IRJET Journal
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
IRJET Journal
SEISMIC ANALYSIS OF G+7 RESIDENTIAL BUILDING WITH AND WITHOUT SHEAR WALL
SEISMIC ANALYSIS OF G+7 RESIDENTIAL BUILDING WITH AND WITHOUT SHEAR WALL
IRJET Journal
Comparative Analysis of Conventional Steel Structure with Diagrid Structures ...
Comparative Analysis of Conventional Steel Structure with Diagrid Structures ...
IRJET Journal
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET Journal
“A REVIEW PAPER ON BEHAVIOR OF GRIDSHELL STRUCTURE”
“A REVIEW PAPER ON BEHAVIOR OF GRIDSHELL STRUCTURE”
IRJET Journal
Performance Study of High Rise Building with Diagrid System Under Dynamic Loa...
Performance Study of High Rise Building with Diagrid System Under Dynamic Loa...
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
IRJET Journal
Analysis of diagrid structure in comparison with exterior braced frame structure
Analysis of diagrid structure in comparison with exterior braced frame structure
eSAT Journals
Corelative Study of Regular and Mass-Irregular Multistorey Building
Corelative Study of Regular and Mass-Irregular Multistorey Building
IRJET Journal
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET Journal
“Analysis of a Multistorey Building with Grid slab in Different Seismic Zones...
“Analysis of a Multistorey Building with Grid slab in Different Seismic Zones...
IRJET Journal
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
IRJET Journal
Seismic Performance of Circular And Rectangular Column by Cyclic And Monotoni...
Seismic Performance of Circular And Rectangular Column by Cyclic And Monotoni...
IRJET Journal
OPTIMAL GRID GEOMETRY OF A DIAGRID STRUCTURE
OPTIMAL GRID GEOMETRY OF A DIAGRID STRUCTURE
IRJET Journal
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET Journal
Performance Analysis of the Tall Structure with Diagrid for Seismic Loading
Performance Analysis of the Tall Structure with Diagrid for Seismic Loading
IRJET Journal
Performance based design of Tall RC Structures considering Uncertainty in pla...
Performance based design of Tall RC Structures considering Uncertainty in pla...
IRJET Journal
IRJET- Design and Analysis of Concrete Diagrid Building and its Comparison wi...
IRJET- Design and Analysis of Concrete Diagrid Building and its Comparison wi...
IRJET Journal
Similar to “Analysis of Multi Storied Diagrid Structure using ETABS Software”
(20)
Seismic Analysis of I Shaped and Plus Shaped Building with and without damper
Seismic Analysis of I Shaped and Plus Shaped Building with and without damper
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
Optimum Design of Concrete Diagrid Building and its Comparison with Conventio...
SEISMIC ANALYSIS OF G+7 RESIDENTIAL BUILDING WITH AND WITHOUT SHEAR WALL
SEISMIC ANALYSIS OF G+7 RESIDENTIAL BUILDING WITH AND WITHOUT SHEAR WALL
Comparative Analysis of Conventional Steel Structure with Diagrid Structures ...
Comparative Analysis of Conventional Steel Structure with Diagrid Structures ...
IRJET- Parametric Study on Multistoried Diagrid Structure
IRJET- Parametric Study on Multistoried Diagrid Structure
“A REVIEW PAPER ON BEHAVIOR OF GRIDSHELL STRUCTURE”
“A REVIEW PAPER ON BEHAVIOR OF GRIDSHELL STRUCTURE”
Performance Study of High Rise Building with Diagrid System Under Dynamic Loa...
Performance Study of High Rise Building with Diagrid System Under Dynamic Loa...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of Seismic Behaviors of RC Frame Structure With Bracing System and W...
Analysis of diagrid structure in comparison with exterior braced frame structure
Analysis of diagrid structure in comparison with exterior braced frame structure
Corelative Study of Regular and Mass-Irregular Multistorey Building
Corelative Study of Regular and Mass-Irregular Multistorey Building
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
IRJET- A Study on Behaviour of Diagrid Structure using Pushover Analysis
“Analysis of a Multistorey Building with Grid slab in Different Seismic Zones...
“Analysis of a Multistorey Building with Grid slab in Different Seismic Zones...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Comparison of Seismic Resistance of Moment Resisting RC Building using Shear ...
Seismic Performance of Circular And Rectangular Column by Cyclic And Monotoni...
Seismic Performance of Circular And Rectangular Column by Cyclic And Monotoni...
OPTIMAL GRID GEOMETRY OF A DIAGRID STRUCTURE
OPTIMAL GRID GEOMETRY OF A DIAGRID STRUCTURE
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
IRJET- Comparative Seismic Evaluation of Response of RC Building with Shear W...
Performance Analysis of the Tall Structure with Diagrid for Seismic Loading
Performance Analysis of the Tall Structure with Diagrid for Seismic Loading
Performance based design of Tall RC Structures considering Uncertainty in pla...
Performance based design of Tall RC Structures considering Uncertainty in pla...
IRJET- Design and Analysis of Concrete Diagrid Building and its Comparison wi...
IRJET- Design and Analysis of Concrete Diagrid Building and its Comparison wi...
More from IRJET Journal
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
IRJET Journal
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
IRJET Journal
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
IRJET Journal
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
IRJET Journal
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
IRJET Journal
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
IRJET Journal
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
IRJET Journal
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
IRJET Journal
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
IRJET Journal
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
IRJET Journal
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
IRJET Journal
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
IRJET Journal
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
IRJET Journal
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
IRJET Journal
React based fullstack edtech web application
React based fullstack edtech web application
IRJET Journal
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
IRJET Journal
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
IRJET Journal
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
IRJET Journal
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
IRJET Journal
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
IRJET Journal
More from IRJET Journal
(20)
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE...
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
STUDY THE EFFECT OF RESPONSE REDUCTION FACTOR ON RC FRAMED STRUCTURE
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
A COMPARATIVE ANALYSIS OF RCC ELEMENT OF SLAB WITH STARK STEEL (HYSD STEEL) A...
Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
A Review on the Progress and Challenges of Aluminum-Based Metal Matrix Compos...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A Review of “Seismic Response of RC Structures Having Plan and Vertical Irreg...
A REVIEW ON MACHINE LEARNING IN ADAS
A REVIEW ON MACHINE LEARNING IN ADAS
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
Long Term Trend Analysis of Precipitation and Temperature for Asosa district,...
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
P.E.B. Framed Structure Design and Analysis Using STAAD Pro
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
A Review on Innovative Fiber Integration for Enhanced Reinforcement of Concre...
Survey Paper on Cloud-Based Secured Healthcare System
Survey Paper on Cloud-Based Secured Healthcare System
Review on studies and research on widening of existing concrete bridges
Review on studies and research on widening of existing concrete bridges
React based fullstack edtech web application
React based fullstack edtech web application
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A Comprehensive Review of Integrating IoT and Blockchain Technologies in the ...
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED CONCRETE.
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Optimizing Business Management Process Workflows: The Dynamic Influence of Mi...
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Multistoried and Multi Bay Steel Building Frame by using Seismic Design
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Cost Optimization of Construction Using Plastic Waste as a Sustainable Constr...
Recently uploaded
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
Suhani Kapoor
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
sanyuktamishra911
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls in Nagpur High Profile
Extrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
120cr0395
result management system report for college project
result management system report for college project
Tonystark477637
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
Call Girls in Nagpur High Profile
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Call Girls in Nagpur High Profile
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
purnimasatapathy1234
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur High Profile
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
SIVASHANKAR N
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
roncy bisnoi
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
SIVASHANKAR N
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
Suhani Kapoor
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Call Girls in Nagpur High Profile
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
KurinjimalarL3
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Dr.Costas Sachpazis
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
Tsuyoshi Horigome
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)
simmis5
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur High Profile
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Christo Ananth
Recently uploaded
(20)
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
VIP Call Girls Service Hitech City Hyderabad Call +91-8250192130
KubeKraft presentation @CloudNativeHooghly
KubeKraft presentation @CloudNativeHooghly
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Call Girls Service Nashik Vaishnavi 7001305949 Independent Escort Service Nashik
Extrusion Processes and Their Limitations
Extrusion Processes and Their Limitations
result management system report for college project
result management system report for college project
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Microscopic Analysis of Ceramic Materials.pptx
Microscopic Analysis of Ceramic Materials.pptx
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
High Profile Call Girls Nagpur Meera Call 7001035870 Meet With Nagpur Escorts
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
MANUFACTURING PROCESS-II UNIT-2 LATHE MACHINE
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Pimpri Chinchwad Call Me 7737669865 Budget Friendly No Advance Boo...
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
MANUFACTURING PROCESS-II UNIT-5 NC MACHINE TOOLS
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
Top Rated Pune Call Girls Budhwar Peth ⟟ 6297143586 ⟟ Call Me For Genuine Se...
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
SPICE PARK APR2024 ( 6,793 SPICE Models )
SPICE PARK APR2024 ( 6,793 SPICE Models )
Java Programming :Event Handling(Types of Events)
Java Programming :Event Handling(Types of Events)
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call Girls Service Nagpur Tanvi Call 7001035870 Meet With Nagpur Escorts
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
Call for Papers - Educational Administration: Theory and Practice, E-ISSN: 21...
“Analysis of Multi Storied Diagrid Structure using ETABS Software”
1.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 05 | May 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 3702 “Analysis of Multi Storied Diagrid Structure using ETABS Software” Rohit Sunil Navale Department of Civil Engineering SND College of Engineering & Research Center Babhulgaon Tal.yeola Dist.Nashik Prof. Nikam PravinAnkushrao Department of Civil Engineering SND College of Engineering & Research Center Babhulgaon Tal.yeola Dist.Nashik Dr Mate N.U. Department of Civil Engineering Amrutvahini College of Engineering, Sangamner, Dist.Ahehmadnagar ---------------------------------------------------------------------***-------------------------------------------------------------------- Abstract -The increasing requirement to achieve larger heights has fueled the growth of structural system concepts for tall buildings. Structural engineers have been able to design and construct buildings that have grown higher and higher for over a century. Many new ideas have arisen as a result of this process, including the relatively new and ground-breaking high-rise diagrid structural system. The diagrid structure was born from the development of this notion to a system without vertical columns. For tall buildings, digrid structural systems are developing as structurally efficient and architecturally remarkable assemblies. Diagrid structures are effective in terms of both strength and stiffness in giving solutions.A tall skyscraper with a G+16 storey structure is investigated and compared under various circumstances. We explore three modules in our project: structures without diagonal grids, structures with diagonal grids at selected bay's outer face, and structures with diagonal grids at selected bay's inner face. Storey drifts and displacement will be compared, as well as axial forces and bending moments, and shear forces in the column. Keywords: Displacement, Story Drift, Bending Moment, Axial Forces, Shear Forces, INTRODUCTION: - The diagrid is a type of diagonal member that is used in both gravity and lateral load resisting systems. Braced tube structures have evolved into diagrid systems. Engineers can now use cutting-edge structural systems to construct structures that are more than 100 stories tall. Researchers began using the term diagrid, which is a mix of diagonal and grid, in 1970. Diagrid is a steel-frame construction method that results in triangular structures with diagonal support beams. Aside from eliminating perimeter columns, the diagrid design has other advantages. Vertical load carrying capability is often provided by columns, with diagonals or braces providing stability and resistance to large forces like as wind and seismic stresses. The diagrid's diagonal member carries both shear and moment. As a result, the best angle for placing diagonals is determined by the height of the building. 1. Objective of Study: 1. ETAB Software Diagrid Structure Analysis 2. To learn how high-rise constructions react to earthquakes. 3. To comprehend the behaviour of high-rise constructions in a certain location when subjected to diagrid loading. 4. Determine whether a diagonal grid is suitable for a certain construction.
2.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 05 | May 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 3703 LITERATURE REVIEW:- • "Diagrid: An innovative, sustainable, and efficient structural system," by Esmaeel Asadi and Hojjat Adeli, published in 2016. This study discusses several diagrid configurations, as well as the primary aspects that influence their behaviour and design parameters. The diagrid applications for free form steel and concrete structures are presented, demonstrating the diagrid's applicability in structural design for complicated buildings. It also covers diagrid connections, nonlinear diagrid behaviour, and diagrid structural control. The article suggests that diagrid has the potential to become a more extensively employed structural system in mid to highrise buildings due to its exceptional lateral stiffness and aesthetic qualities. The adjustability of diagrid density and diagonal angle, as well as the flexibility of triangulated diagrid parts to produce complex forms, are the essential structural properties of diagrids. • "Improving the seismic performance of diagrid buildings with buckling constrained braces," Saman Sadeghi and Fayaz R. Rofooei, 2019. The seismic performance of diagrids with buckling limited bracing is investigated in this study (BRBs). The seismic performance factors of six three-dimensional diagrid structures with varied heights and diagonal angles that were modelled using the Open sees programme are evaluated using nonlinear static analysis. The findings show that utilising BRBs enhances the seismic performance of the models investigated by collecting plastic damages in the BRBs and spreading plastic hinges more uniformly across the models. • "Seismic fragility evaluation of a diagrid structure based on energy approach," Majid Moradi and Moein Abdolmohammadi (2020). The goal of this research is to use energy approach principles to analyse the seismic behaviour of diagrid structural systems under near-field and far-field earthquakes in order to acquire a better understanding of their seismic behaviour and the benefits of adopting energy approaches. The Incremental Dynamic Analysis (IDA) method and a finite element model are used to investigate the behaviour of a 50-story skyscraper. The results reveal that the structure is more vulnerable in far-field earthquakes than in near-field earthquakes, using both the maximum story drift and energy approaches. METHODOLODY The following is the methods used to attain the aforementioned goals: i) Conduct a literature review ii) In ETAB Software, choose a building model for the study. iii) Create a diagonal column model of the chosen structure (diagrid bracing). Model 1: Plain hexagonal structure with no bracing. Model 2: A structure featuring diagonal bracing (diagrids) on the ground, first, and second floors. Model 3: A structure having diagonal bracing on the 13th, 14th, and 15th floors. Model 4: A structure featuring cross bracing on the 7th and 8th floors. iv) A comparison assessment of the data produced from the analysis in ETAB Software and a seismic analysis of the selected building model. v) Discussions and observations of outcomes
3.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 05 | May 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 3704 Figure 1: 3D view of G+16 Storey Model without diagrid Figure 2: 3-D View of Model 2 Figure 3 : 3-D View of Model 3 Figure 4 : 3-D View of Model 4 Model 1: Plain hexagonal structure with no bracing. ETAB Software was used to create a basic hexagonal model that included columns, beams, and slabs. The following are the sizes, concrete grades, and rebar grades: T Table 1. Item Specification Item Storey Size Grade of Concrete Grade of Rebars Beam All Storeys 230 X 600 mm M30 HYSD500 Column First 3 Storey 1000 X 1000 mm M30 HYSD500 4 To 6 Storey 975X975 mm 7 To 9 Storey 950X950 mm 10 To 12 Storey 925X925 mm 13 To 15 Storey 900X900 mm 16 Storey 875X875 mm Two Way Slab All Storeys 150 mm thick M30 - Shear Wall 200 mm thick M30 -
4.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 05 | May 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 3705 The load pattern applied on the structures is as follows: Table 2. Load Specifications Basic Load Combinations as per [IS 456:2000, Table 18, pg. no. 68]. 1. 1.5(DL+LL) 14. 1.2(DL+LL+EQX) 2. 1.2(DL+LL+WLX) 15. 1.2(DL+LL+EQ-X) 3. 1.2(DL+LL+WL-X) 16. 1.2(DL+LL+EQY) 4. 1.2(DL+LL+WLY) 17. 1.2(DL+LL+EQ-Y) 5. 1.2(DL+LL+WL-Y) 18. 1.5(DL+EQX) 6. 1.5(DL+WLX) 19. 1.5(DL+EQ-X) 7. 1.5(DL+WL-X) 20. 1.5(DL+EQY) 8. 1.5(DL+WLY) 21. 1.5(DL+EQY-Y) 9. 1.5(DL+WLY-Y) 22. 0.9DL+1.5EQX 10. 0.9DL+1.5WLX 23. 0.9DL+1.5EQ-X 11. 0.9DL+1.5WL-X 24. 0.9DL+1.5EQY 12. 0.9DL+1.5WLY 25. 0.9DL+1.5EQ-Y 13. 0.9DL+1.5WL-Y 14. Various load combinations as per [IS 1893 part-1:2016, 6.3.2.2, pg. no. 8] have been implemented on the structure. They are as follows: 15. 1.2DL+1.2LL+1.2EQX+0.36EQY 16. 1.2DL+1.2LL-1.2EQX-0.36EQY 17. 1.2DL+1.2LL+1.2EQY+0.36EQX 18. 1.2DL+1.2LL-1.2EQY-0.36EQX 19. 1.5DL+1.5EQX+0.45EQY 20. 1.5DL-1.5EQX-0.45EQY 21. 1.5DL+1.5EQY+0.45EQX 22. 1.5DL-1.5EQY-0.45EQX 23. 0.9DL+1.5EQX+0.45EQY 24. 0.9DL-1.5EQX-0.45EQY 25. 0.9DL+1.5EQY+0.45EQX 12. 0.9DL-1.5EQY-0.45EQX Model 2: Building with diagonal bracing(diagrids) at Ground floor, 1st floor and 2nd floor. Table 3. Diagrid Specifications Model 3: Building with diagonal bracing at 13th storey, 14th floor and 15th floor. Table 3. Diagrid Specifications Define Load Pattern Type of Load Load Dead Load (DL) Dead - Live Load (LL) Live 2 kN/m Floor Furnish Load Super Dead 1.5 kN/m Wall Load Super Dead 10 kN/m Earthquake Load in x-dir (EQX) Seismic Seismic Zone Factor Z- 0.16 Importance Factor I- 1.2 Earthquake Load in y-dir (EQY) Seismic Seismic Zone Factor Z- 0.16 Importance Factor I- 1.2 Item Storey Size Grade of Concrete Diagrid On ground floor, 1st and 2nd floor 230 X 230 mm M30 Item Floor Size Grade of Concrete Diagrid On 13th , 14th and 15th floor 230 X 230 mm M30
5.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 05 | May 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 3706 Model 4: Building with cross bracing at 7th floor and 8th floor. Table 3. Diagrid Specifications Conclusion and Discussion: Model 1: Plain hexagonal structure with no bracing. A hexagonal building with G+16 stories and no diagrid is considered. The greatest drift found after the analysis was 0.001321. Under the operation of the design base of shear, storey drift in any storey shall not exceed 0.004 times the storey height [IS 1893 part1:2016]. As a result, the structure is not safe since it shows more deflection than is required, namely 0.0012. Model 2: A structure featuring diagonal bracing (diagrids) on the ground, first, and second floors. A 16-story hexagonal building with diagrids on the ground, first, and second floors is considered. The largest drift found after the analysis was 0.001248.As a result, the structure is safe because it has the same deflection as the required 0.0012. Model 3: A structure having diagonal bracing on the 13th, 14th, and 15th floors. A 16-story hexagonal skyscraper featuring diagrids on the 13th, 14th, and 15th floors is being considered. The largest drift found after the analysis was 0.001069.As a result, the structure is safe because it has less deflection than required, namely 0.0012. Model 4: A structure featuring cross bracing on the 7th and 8th floors. A 16-story hexagonal structure featuring diagrids on the 7th and 8th floors is being studied. The greatest drift found after the analysis was 0.00099. As a result, the structure is safe because it has less deflection than required, namely 0.0012. Graph 1. Maximum drift of the four models. Graph 2. Maximum displacement of the four models. CONCLUSION 1. According to IS 1893 part-1 2016, the lateral displacement of hexagonal buildings is greater than envisaged. 2. It was discovered that the maximum drift was correct to the required drift according to IS code after installing diagonal bracings (Diagrid) at the ground 1st and 2nd floors. 3. After installing diagonal bracings (Diagrid) on the 13th, 14th, and 15th floors, it was discovered that the maximum Item Storey Size Grade of Concrete Diagrid On 7th and 8th floor 230 X 230 mm M30
6.
International Research Journal
of Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 09 Issue: 05 | May 2022 www.irjet.net p-ISSN: 2395-0072 © 2022, IRJET | Impact Factor value: 7.529 | ISO 9001:2008 Certified Journal | Page 3707 drift was less than the IS code-mandated drift. 4. After installing diagonal bracings (Diagrid) on the 7th and 8th floors, it was discovered that the maximum drift was far less than the IS code required drift. 5. As a result, the building's drift when diagrids are installed at the bottom storeys is greater than the building's drift when diagrids are positioned at the top storeys. Also, when the diagrids are put in the structure's middle stories, the drift is reduced to a minimum. 6. When comparing the four models of each column, there is no such variance in axial force and shear force. 7. The bending moments of the models differ slightly. REFERENCES 1. Esmaeel Asadi and Hojjat Adeli, Wiley, Dec 2016, "Diagrid: An innovative, sustainable, and efficient structure system." 2. Saman Sadeghi, Fayaz R. Rofooei, “Improving the seismic performance of diagrid structures using buckling restrained braces.”, Journal of Constructional Steel Research 166, 2019. 3."Seismic fragility assessment of a diagrid structure using the energy technique," Majid Moradi and Moein Abdolmohammadi, Journal of Constructional Steel Research 174, 2020. 4. Vahid Mohsenian, Saman Padashpour, Iman Hajirasouliha, “Seismic reliability analysis and estimation of multilevel response modification factor for steel diagrid structural systems.”, Journal of Building Engineering, 2019. 5. G.B. Ramesh Kumar and Neha Tirkey, "Analysis on the diagrid structure with the Conventional building frame using ETABS," Materials Today: Proceedings, Elsevier, 2019."Analyzing alternative configurations of variable angle diagrid structures." by Kamil Ashraf Bhat and Peerzada Danish, Elsevier, Materials Today: Proceedings, 2020
Download now