4. Mestex manufacturing facility
offers multiple assembly bays and
painting capability.
Three Manufacturing building
complex
Production
Capacity
MESTEX
5. MESTEX
A DIVISION OF MESTEK, INC
Indirect
Indirect/Direct
Evaporative
Cooling
Direct
Evaporative
Cooling
Hydronic
Unit
Heaters
Door
Curtains
Hydronic
Face and
Bypass Coils
Direct and
Indirect Gas
Fired
Products
Packaged
DOAS
Systems
Air
Intake
HoodsCRAH
Unit
CRAHU
Unit
Air
Turnover
Evap
Air Turnover
Unit
National Accounts
Industrial
OEM
MESTEX
6. Direct Gas Fired Equipment
Features and key options:
• Direct Drive Plenum Fans
with VFD speed control
• Airflow station
• DDC controls
• Mixing box
• Cooling coil
• Evaporative cooling
• Ventilation-only versions
available
Outdoor
• 1,600 to 100,000 cfm
Indoor
• 1,600 to 64,000 cfm
Universal
• 2,000 to 16,000 cfm
MESTEX
7. Direct Fired Applications
• Kitchen Make-up Air
• Waste Water Treatment Plants
• Factories
• Painting, Welding, Plating, & Circuit Board Etching
Processes
• General Warehousing
• Very High Building Exhaust (building negative
pressure)
• LEED Point Requirements
• High Efficiency Heating
• BacNet Compatible
• Low Cost Cooling
MESTEX
8. Indirect Gas Fired Equipment
Features and key options:
• Direct Drive Plenum Fans with
VFD speed control
• DDC controls
• Mixing box
• Cooling coil
• Evaporative cooling
• Ventilation-only versions
available
Outdoor
• 2,300 to 46,000 cfm
Indoor
• 1,500 to 94,000 cfm
MESTEX
9. Indirect Fired Applications
• Kitchen Make-up Air
• Painting Processes
• Institutions
• Schools
• Storage Buildings
• Chemical Processing or Production
• Pharmaceutical Research Labs
• General Warehousing
• Very High Building Exhaust
• (building negative pressure)
MESTEX
10. Air Turnover Equipment – Warehouse/Storage
Product Temperature Control
Features and key options:
• Centrifugal or Prop Fans
• DDC controls
• Mixing box
• Cooling coil
• Filtration Options
• Optional outdoor applications
• Ventilation-only versions
available
Air Turnover
• 6,600 to 150,000 cfm
MESTEX
11. Air Turnover Applications
• Distribution Centers
• General Warehousing
• Pharmaceutical Storage
• Manufacturing Plant
• Metal Buildings
• Any open area building
• General Space Heating & Cooling
• BacNet Compatible
MESTEX
12. Hydronic Coils and Unit Heaters –
Outside Air Pre-treatment, Process
Exhaust Make-Up
Unit Heater and Air Handler
features and key options:
• VFD
• Revolving air discharge
system
• High bay throw designs
• Stainless steel construction
Integral Face and Bypass
Coils
• Actuator type options
• Special coatings
• Special materials
Integral Face and Bypass Coils
Steam or Hot Water Unit Heaters
• 900 to 27,000 cfm
Combustion Air Pre-Heaters
• 900 to 26,000 cfm
Steam or Hot Water Air Handlers
• 1,500 to 40,000 cfm
MESTEX
13. Air Curtains – Overhead Door Infiltration
Control, Infiltration Temperature Control
Features and key options:
• Steam or hot water coils
• Gas heat
No heat
• 2,800 to 24,000 cfm
Steam or Hot Water Heat
• 1,500 to 30,000 cfm
Gas heat
• 2,800 to 24,000 cfm
MESTEX
14. Dedicated Outdoor Air Systems –
Packaged Cooling Designed for High
Temperatures, Wide Temperature Swings,
Dehumidification
Features and key options:
• VFD
• DDC controls
• Direct drive plenum fans
• Enthalpy wheel
• Return Air/Mixed Air Option
• Gas heat
• Electric heat
Split system
• 1,500 to 14,000 cfm
Packaged unit
• 1,500 to 14,000 cfm
MESTEX
15. Evaporative Cooling Solutions
Features and key options:
• VFD
• DDC controls
• Direct drive plenum fans
• Cooling coils
• Gas heat
Direct
• 5,000 to 64,000 cfm
Indirect
• 1,500 to 37,500 cfm
Indirect/direct
• 1,500 to 37,500 cfm
MESTEX
16. Indirect or Indirect/Direct Evaporative
Cooling Applications
• Data Centers
• Chemical Processing or Production
• ASHRAE 62.1 Requirements
• LEED Point Requirements
• Low Cost Cooling
MESTEX
17. Indirect & Indirect Direct Evaporative Cooling
• Aztec ASC Line
• Indirect or indirect/direct evap
• DDC controls with Internet access
available
• Stainless steel evap sections
• Fully welded floor pans
• Glassdek UL900cl2 media
• Cleanable media pre-filters
• Direct drive plenum fan(s)
• VFD capable
• Automatic fill and drain system
• 1,500 – 37,500 cfm range
• 1 to 18 - 42U racks
MESTEX
18. 1946 Alton
introduces
industrial
grade direct
evap cooling
system
1989 Aztec
introduces
“spray
cooling”
technology to
industrial
market
1990 Aztec
patents
indirect/direct
evap cooling
1990 Aztec
introduces
“air-to-air”
indirect evap
cooling
technology
1991 Aztec
patents
indirect/direct
evap cooling
using cooling
tower/coil
technology
1995 Aztec
discontinues
“spray
cooling”
technology to
reduce
customer
operating
costs
1995 Aztec
discontinues
“air-to-air”
indirect evap
cooling as less
efficient than
tower/coil
technology
2011 Aztec
reconfigured
for higher
efficiency air
handling
2012 Aztec
introduces
web-enabled,
networkable
DDC controls
to evap
market
Aztec/Alton Design History
MESTEX
19. Air Filter/Intake Hoods
• High air handling capacity 20,000, 40,000, 60,000,
80,000 & 120,000 cfm of air delivery per hood.
• Heavy duty welded iron base
• Filter options up to MERV13
• Mist eliminator filters available as pre-filters
• Fully welded floor panels
• IAQ type drain pans
• Access doors with lift and turn latches
• Designed for velocities that minimize
m moisture entrainment
• Airflow volume/shut off dampers optional
• Heavy duty steel grate access covers over interior
air openings
• Optional C/W or D/X coil for precooling
Mist Eliminator Design
Louver Design
The Intake Hood provides filtered outside air
utilizing “free cooling” or “adiabatic cooling”
solutions.
MESTEX
23. Aztec IT Pod Evaporative Cooling Systems
• Cold supply temperatures for the DEC
version roughly 3 degrees F above
ambient wet bulb. (up to 88%
effectiveness)
• DDC controls available.
• Direct drive fans standard.
• Filter options up to MERV16
• Supplemental mechanical cooling coils
available
• Fully welded floor panels
• Up to 7,000 cfm of air delivery per tunnel
in standard mode.
MESTEX
25. Computational Fluid Dynamics
(CFD)
CFD Software Utilized by Mestex, FloVENT – Mentor Graphics
• Features advanced smart parts that can be used for representing
physical systems
• Supports parallel processing, thereby minimizing time taken to run
individual solutions
• Suitable for room level modeling such as industrial/commercial buildings,
HVAC buildings and components, data centers, shopping malls, theaters,
storage facilities and warehouses
MESTEX