SlideShare a Scribd company logo
1 of 61
Presentation Coverage
Air Heater & Boiler Performance Indices
Improvements in Measurements - Case
Studies
Calculation of Boiler Efficiency - Sample
Calculations
05/08/19 1Manohar Tatwawadi
Air Heater - Performance Indicators
• Air-in-Leakage
• Gas Side Efficiency
• Heat X - ratio
• Flue gas temperature drop
• Air side temperature rise
• Gas & Air side pressure drops
(The indices are affected by changes in entering
air or gas temperatures, their flow quantities and
coal moisture)
05/08/19 2Manohar Tatwawadi
AH Performance Monitoring
• O2 & CO2 in FG at AH Inlet
• O2 & CO2 in FG at AH Outlet
• Temperature of gas entering / leaving air heater
• Temperature of air entering / leaving air heater
• Diff. Pressure across AH on air & gas side
(Above data is tracked to monitor AH performance)
05/08/19 3Manohar Tatwawadi
Air heater Air-in-leakage
All units that operate with a rotary type regenerative air
heater experience some degree of air leakage across
the air heater seals.
An increase in air leakage across the seals of an AH
results in increased ID and FD fan power and flow rate
of flue gas. Sometimes it can put limitations on unit
loading as well.
Typically air heater starts with a baseline leakage of 8
to 10% after an overhaul.
05/08/19 4Manohar Tatwawadi
Air Heater Leakage (%)
The leakage of the high pressure air to the low
pressure flue gas is due to the Differential Pressure between
fluids, increased seal clearances in hot condition, seal
erosion / improper seal settings.
Increased AH leakage leads to
• Reduced AH efficiency
• Increased fan power consumption
• Higher gas velocities that affect ESP performance
• Loss of fan margins leading to inefficient operation and at
times restricting unit loading
05/08/19 5Manohar Tatwawadi
Air Heater Leakage (%)
• Direct - Hot End / Cold End
(60% through radial seals + 30% through Circumferential
bypass)
Air leakage occurring at the hot end of the air
heater affects its thermal and hydraulic
performance while cold end leakage increases
fans loading.
• Entrained Leakage due to entrapped air between
the heating elements (depends on speed of rotation
& volume of rotor air space)
05/08/19 6Manohar Tatwawadi
Rotary Air heater
RADIAL SEAL
AXIAL
SEAL
BYPASS SEAL
COLD END
HOT END
HOT INTERMEDIATE
05/08/19 7Manohar Tatwawadi
SEALS ARRANGEMENT
05/08/19 8Manohar Tatwawadi
Double seal
05/08/19 9Manohar Tatwawadi
Flexible seal assembly - Cold Condition
05/08/19 10Manohar Tatwawadi
Flexible seal assembly - Hot Condition
05/08/19 11Manohar Tatwawadi
Leakage Assessment
• Leakage assessment must be done by a grid survey using
a portable gas analyser.
• Calculation of leakage using CO2 values is preferred
because of higher absolute values and lower errors.
• Method of determination of O2 or CO2 should be the same at
inlet and outlet - wet or dry (Orsat)
• Single point O2 measurement feedback using orsat is on dry
basis while zirconia measurement is on wet basis.
• Leakage assessment is impacted by air ingress from
expansion joints upstream of measurement sections.
05/08/19 12Manohar Tatwawadi
Air Heater Leakage (%)
Weight of air passing from air side to gas side
This leakage is assumed to occur entirely between air
inlet and gas outlet
05/08/19 13Manohar Tatwawadi
Air Heater Leakage - Calculation
Empirical relationship using the change in concentration of
O2 or CO2 in the flue gas
= CO2in - CO2out * 0.9 * 100
CO2out
= O2out - O2in * 0.9 * 100 = 5.7 – 2.8 * 90
(21- O2out) (21-5.7)
= 17.1 %
CO2 measurement is preferred due to high absolute values;
In case of any measurement errors, the resultant influence on
leakage calculation is small.
05/08/19 14Manohar Tatwawadi
Gas Side Efficiency
Ratio of Gas Temperature drop across the air heater,
corrected for no leakage, to the temperature head.
= (Temp drop / Temperature head) * 100
where Temp drop = Tgas in -Tgas out (no leakage)
Temp head = Tgasin - T air in
Gas Side Efficiency = (333.5-150.5) / (333.5-36.1) = 61.5 %
05/08/19 15Manohar Tatwawadi
Tgas out (no leakage) = The temperature at which the gas
would have left the air heater if there were no AH leakage
= AL * Cpa * (Tgas out - Tair in) + Tgas out
Cpg * 100
Say AH leakage – 17.1%, Gas In Temp – 333.5 C, Gas Out Temp –
133.8 C, Air In Temp – 36.1 C
Tgasnl = 17.1 * (133.8 – 36.1) + 133.8 = 150.5 C
100
05/08/19 16Manohar Tatwawadi
HEAT X – Ratio
Ratio of heat capacity of air passing through the air heater to
the heat capacity of flue gas passing through the air heater.
= Wair out * Cpa
Wgas in * Cpg
= Tgas in - Tgas out (no leakage)
Tair out - Tair in
Say AH leakage – 17.1%, Gas In Temp – 333.5 C, Gas Out Temp –
133.8 C , Air In Temp – 36.1 C, Air Out Temp – 288 C
X ratio = (333.5 – 150.5) / (288 –36.1) = 0.73
05/08/19 17Manohar Tatwawadi
X-Ratio depends on
• moisture in coal, air infiltration, air & gas mass flow rates
• leakage from the setting
• specific heats of air & flue gas
X-ratio does not provide a measure of thermal performance
of the air heater, but is a measure of the operating
conditions.
A low X-ratio indicates either excessive gas weight through
the air heater or that air flow is bypassing the air heater.
A lower than design X-ratio leads to a higher than design
gas outlet temperature & can be used as an indication of
excessive tempering air to the mills or excessive boiler
setting infiltration.
05/08/19 18Manohar Tatwawadi
Pressure drops across air heater
• Air & gas side pressure drops change approximately in
proportion to the square of the gas & air weights through
the air heaters.
• If excess air is greater than expected, the pressure drops
will be greater than expected.
• Deposits / choking of the basket elements would lead to an
increase in pressure drops
• Pressure drops also vary directly with the mean absolute
temperatures of the fluids passing through the air heaters
due to changes in density.
05/08/19 19Manohar Tatwawadi
Air Ingress Calculations
Air ingress quantification is done with the same formulae
as those used for calculation of AH leakage
Air ingress
= O2out - O2in * 0.9 * 100 = 6.5 - 5.7 * 90
(21- O2out) 21 - 6.5
= 4.96 %
The basis of O2 or CO2 calculation should be the same –
either wet or dry.
05/08/19 20Manohar Tatwawadi
Air Heaters Temp measurements
• Thermocouples for flue gas temperatures at AH inlet as
well as exit are generally clustered on one side.
• A grid survey is needed for representative values.
• Exit gas temperatures need to be corrected to a
reference ambient and to no leakage conditions for
comparison.
• Thermocouples for SA temperature measurement at
AH outlet are mounted too close to air heaters and need
to be relocated downstream to avoid duct stratification.
• Additional mill or changes in coal quality change
thermal performance of a tri-sector air heater in a very
major way; performance evaluation is difficult.05/08/19 21Manohar Tatwawadi
Flue gas temperature as measured in common ducts leading
to ESPs in 500 MW units is more representative than weighted
averages of temperatures measured at individual AH exits.
Flue Gas Temperatures C
T 3 T 4 T 9 T 11 T 14
PAPH A Outlet 142.7 133.2 145.7 139.1 139.9
SAPH A Outlet 132.5 133.1 139.8 138.1 137.0
Eqv. Temp A side 135.9 133.1 141.7 138.5 138.0
Grid Average Left 141.8 146.5 147.3 144.1 143.6
PAPH B Outlet 142.2 134.5 143.9 137.9 149.5
SAPH B Outlet 135.9 132.4 139.6 136.2 143.2
Eqv. Temp B side 138.0 133.1 141.0 136.7 145.3
Grid Average Right 144.0 147.5 149.9 148.4 150.4
Flue Gas Temperature at AH outlet
05/08/19 22Manohar Tatwawadi
Boiler Performance
Boiler Efficiency
The % of heat input to the boiler absorbed by the
working fluid (Typically 85-88%)
05/08/19 23Manohar Tatwawadi
Boiler Efficiency…
Boiler Efficiency can be determined by
a) Direct method or Input / Output method
b) Indirect method or Loss method
05/08/19 24Manohar Tatwawadi
Direct Method
100
valuecalorificGrossxratefiringFuel
enthalpy)waterfeedenthalpy(steamxrateflowSteam
xEfficiencyBoiler
−
=
05/08/19 25Manohar Tatwawadi
Boiler Efficiency…
Direct method or Input / Output method measures the
heat absorbed by water & steam & compares it with
the total energy input based on HHV of fuel.
• Direct method is based on fuel flow, GCV, steam flow
pressure & temperature measurements. For coal
fired boilers, it’s difficult to accurately measure coal
flow and heating value on real time basis.
• Another problem with direct method is that the extent
and nature of the individual components losses is not
quantified.
05/08/19 26Manohar Tatwawadi
Boiler Efficiency…
Indirect method or Loss method
For utility boilers efficiency is generally calculated by heat
loss method wherein the component losses are calculated
and subtracted from 100.
Boiler Efficiency = 100 - Losses in %
05/08/19 27Manohar Tatwawadi
Indirect Method
Boiler Flue gas
Efficiency = 100 – (1+2+3+4+5+6+7+8)
Fuel + Air
1. Dry Flue gas loss
2. H2 loss
3. Moisture in fuel
4. Moisture in air
5. CO loss
7. Fly ash loss
6. Radiation
8. Bottom ash loss
WaterSteam
05/08/19 28Manohar Tatwawadi
Indirect or Loss method
• In Heat Loss method the unit of heat input is the higher
heating value per kg of fuel. Heat losses from various
sources are summed & expressed per kg of fuel fired.
Efficiency = 100 – (L/Hf) * 100
L – losses
Hf – heat input
05/08/19 29Manohar Tatwawadi
Indirect or Loss method
• This method also requires accurate determination of
heating value, but since the total losses make a relatively
small portion of the total heat input (~ 13 %), an error in
measurement does not appreciably affect the efficiency
calculations.
• In addition to being more accurate for field testing, the
heat loss method identifies exactly where the heat
losses are occurring.
05/08/19 30Manohar Tatwawadi
Boiler Efficiency…
Commonly used standards for boiler performance testing are
ASME PTC 4 (1998)
BS – 2885 (1974)
IS: 8753: 1977
DIN standards
05/08/19 31Manohar Tatwawadi
arameters required for computing Boiler Efficiency
AH flue gas outlet O2 / CO2 / CO
AH flue gas inlet and outlet temp C
Primary / Secondary air temp at AH inlet / outlet C
Total Airflow / Secondary Air Flow t/hr
Dry/Wet bulb temperatures C
Ambient pressure bar a
Proximate Analysis & GCV of Coal kcal / kg
Combustibles in Bottom Ash and Flyash
05/08/19 32Manohar Tatwawadi
Boiler Losses Typical values
Dry Gas Loss 5.21
Unburnt Loss 0.63
Hydrogen Loss 4.22
Moisture in Fuel Loss 2.00
Moisture in Air Loss 0.19
Carbon Monoxide Loss 0.11
Radiation/Unaccounted Loss 1.00
Boiler Efficiency 86.63
05/08/19 33Manohar Tatwawadi
Effect of Operating Parameters on Boiler Losses
05/08/19 34Manohar Tatwawadi
Dry Gas Loss (Controllable)
• This is the heat carried away by flue gas at AH outlet
• It’s a function of flue gas quantity and the temperature
difference between air heater exit gas temperature
and FD fan inlet air temperature
• Typically 20 C increase in exit gas temperature ~ 1%
reduction in boiler efficiency.
05/08/19 35Manohar Tatwawadi
Dry Gas Loss…
Sensible Heat of flue gas (Sh)
Sh = Mass of dry flue gas X Sp. Heat X (Tfg – Tair)
Dry Flue Gas Loss % = (Sh / GCV of Fuel) * 100
05/08/19 36Manohar Tatwawadi
Dry Gas loss reduction requires
• Boiler operation at optimum excess air
• Cleanliness of boiler surfaces
• Good combustion of fuel
• Reduction of tempering air to mill.
• Reduction in air ingress
• Cleaning of air heater surfaces and proper
heating elements / surface area
05/08/19 37Manohar Tatwawadi
Unburnt Carbon Loss (Controllable)
• The amount of unburnt is a measure of effectiveness of
combustion process in general and mills / burners in
particular.
• Unburnt carbon includes the unburned constituents in
flyash as well as bottom ash.
• Ratio of Flyash to Bottom ash is around 80:20
• Focus to be on flyash due to uncertainty in repeatability
and representative ness of unburnt carbon in bottom ash
• +50 PF fineness fractions to be < 1-1.5%05/08/19 38Manohar Tatwawadi
Unburnt Carbon Loss (Controllable)
Loss due to Unburnt Carbon
= U * CVc * 100 / GCV of Coal
CVc – CV of Carbon 8077.8 kcal/kg
U = Carbon in ash / kg of coal
= Ash * C (Carbon in coal)
100 100 - C
05/08/19 39Manohar Tatwawadi
Influencing Factors - Unburnt Carbon Loss
• Type of mills and firing system
• Furnace size
• Coal FC/VM ratio, coal reactivity
• Burners design / condition
• PF fineness (Pulveriser problems)
• Insufficient excess air in combustion zone
• Air damper / register settings
• Burner balance / worn orifices
• Primary Air Flow / Pressure
05/08/19 40Manohar Tatwawadi
CO Loss (Controllable)
• Ideally, average CO at gooseneck after combustion
completion should be below 100 ppm and no single
value over 200 ppm
• CO monitors at ID fan discharge in all boilers to
supplement O2 feedback
C + O2 = CO2 + 8084 kcal / kg of Carbon
2C+ O2 = 2CO + 2430 kcal / kg of Carbon
2H2+ O2 = 2H2O + 28922 kcal / kg of Hydrogen
S + O2 = SO2 + 2224 kcal / kg of Sulphur
(We lose 5654 kcal for each kg of CO formed)
05/08/19 41Manohar Tatwawadi
Moisture Loss
Fuel Hydrogen Loss
This loss is due to combustion of H present in fuel. H is
burnt and converted in water, which gets evaporated.
Fuel Moisture Loss
This loss is due to evaporation and heating of inherent
and surface moisture present in fuel. (Can be reduced
by judicious sprays in coal yards)
05/08/19 42Manohar Tatwawadi
Computation - Moisture Loss
Total Moisture Loss
= (9H+M) * Sw / GCV of Coal
Sw – Sensible Heat of water vapour
= 1.88 (Tgo – 25) + 2442 + 4.2 (25 - Trai)
The moisture in flue gases (along with Sulphur in fuel) limits
the temperature to which the flue gases may be cooled due
to corrosion considerations in the cold end of air heater, gas
ducts etc.
05/08/19 43Manohar Tatwawadi
Other Losses
1. Sensible Heat Loss of ash
• Bottom Ash Hoppers
• Eco Hoppers
• AH Hoppers
• ESP hoppers
Sensible Heat Loss (%) = (X / GCV) *100 (~0.5-0.6 %)
X = [{Ash * Pflyash * C pash
* (T go
- T rai
)}
+ {Ash * Pahash * C pash
* (T go
- T rai
)}
+ {Ash * Peash * C pash
* (T gi
-T rai
)}
+ {Ash * Pba * C pash
* (T ba
- T rai
)}]
05/08/19 44Manohar Tatwawadi
Other Losses
2. Radiation Loss through Bottom Ash Hopper
• Coal Flow Rate 135 Tons/Hr
• GCV of Coal 3300 Kcal/Kg
• Eqv. Heat Flux thro’ Bottom opening 27090 Kcal/hr/m2
• Bottom opening area of S-Panel 15.85 m2
Radiation Loss through Bottom Ash Hopper =
[H BOTTOM
* A S-PANEL
*100 ] / [Coal Flow * GCV * 1000]
= 0.096 %
05/08/19 45Manohar Tatwawadi
Other Losses
3. Coal Mill Reject Loss
• Coal Flow 135 T/hr
• Coal Mill Rejects 200 kg/hr
• GCV of Coal 3300 kcal/Kg
• CV of Rejects 900 kcal/Kg
• Mill Outlet Temp Tmillout
90 C
• Reference Temperature Trai
30 C
• Specific Heat of Rejects CpREJECT
0.16 kcal/Kg/C
Loss due to Mill Rejects = X / (Coal Flow * GCV * 1000)
X = [Rejects * (CVREJECT
+ CpREJECT
(Tmillout
– Trai
))* 100 ]
= (0.0408 %)05/08/19 46Manohar Tatwawadi
Other Losses
4. Radiation Loss
Actual radiation and convection losses are difficult to
assess because of particular emissivity of various
surfaces.
05/08/19 47Manohar Tatwawadi
HEAT CREDIT
Heat Credit due to Coal Mill Power
= [MP * 859.86 * 100] / [Coal Flow * GCV * 1000]
Coal Flow Rate Coal FLOW
Tons/Hr
Total Coal Mill Power MP kWh
GCV of Coal Kcal/Kg
05/08/19 48Manohar Tatwawadi
Computations
1. The proximate analysis of coal is used to estimate the
as-fired percentages of carbon & hydrogen using ‘Parr
Formula’and nitrogen using ‘Gebhardt Formula’.
a) UltC = (1-0.01Z)*Cp + (5.0*FuelA) - (50.0*UltS)
Where Z = FuelTM*100 + 110*FuelA + 10*UltS
Qp = (100 * HHV) / (100 - Z)
Vp = 100*(100*FuelVM - 10*FuelA -
10*UltS)/(100-Z)
Cp = 0.0015782 * Qp - 0.2226 * Vp + 37.69
 
Say Fixed Carbon – 23.5, VM – 22.2, TM – 10.6, Ash 43.7 %,
S – 0.4 %; Ultimate C = 34.9%05/08/19 49Manohar Tatwawadi
b) UltH = (1-0.01Z)*Hp + (1.0*FuelA) - (1.5*UltS)
Where Z = FuelTM*100 + 110*FuelA + 10*UltS
Qp = (100 * HHV) / (100 - Z)
Vp = 100 * (100*FuelVM-10*FuelA -
10*UltS)/(100-Z)
Hp = 0.0001707 * Qp +0.0653 * Vp -2.92
Ultimate H = 2.7 %
c) UltN = 2.10 - 1.2*FuelVM = 1.8 %
 
d) UltOAct = 100 - UltCAct + UltHAct + UltNAct +
UltSAct + FuelAAct + FuelTMAct)
  = 5.9 %
05/08/19 50Manohar Tatwawadi
Proximate to Ultimate Conversion
Formulae used for conversion of proximate analysis to
ultimate analysis add to the uncertainty of results.
For some coals, its recommended to use Seyler & Dulong
formula for estimation of C & H and modified Gebardht
formula for estimation of N from proximate analysis.
It’s suggested to get proximate & ultimate analysis of few
coal samples done to validate the formulae being used.
05/08/19 51Manohar Tatwawadi
 
2) The flue gas O2 reading from zirconia probe is based
on a wet analysis. For comparison with the orsat or the
test grid readings, it must be converted to a dry analysis.
If the % moisture in the flue gas is unknown, a typical
value of 8% can be used.
O2 dry = O2 wet / (1-%Moisture/100)
Say O2
dry = 3.2 / (1 – 8 / 100) = 3.48 %
05/08/19 52Manohar Tatwawadi
Manual Inputs Units Symbol Value
Unit Load MW L 210
FW Flow at Eco Inlet T/hr Ffw 615
Wet Bulb Temp C Wb 24
Dry bulb Temp C Db 30
Barometric Pressure mmHgC BP 760
Total Coal Flow T/hr Fin 140
Unburnt C in Bottom Ash % Cba 1.2
Unburnt C in Flysash % Cfa 0.4
Radiation & Unaccounted Loss % Lrad 1.2
% of Flyash to Total Ash % Pfa 80
% of Bottom ash to Total Ash % Pba 20
Ultimate Analysis - As Fired
Carbon % Ca 36.4
Sulfur % S 0.6
Hydrogen % H 2.8
Moisture % M 12.2
Nitrogen % N 1
Oxygen % O 7
Ash % A 40
Gross Calorific Value kcal/kg Gcv 3320
05/08/19 53Manohar Tatwawadi
Avg. Flue Gas O2 - APH Out % O2out 5.0
Avg. Flue Gas CO2 - APH Out % CO2out 14.3
Avg. Flue Gas CO - APH Out ppm COout 50
Avg. Flue Gas Temp - APH In C Tgi 350
Avg. Flue Gas Temp - APH Out C Tgo 135
Primary Air to APH Temp In C Tpai 40
Primary Air from APH Temp Out C Tpao 325
Secondary Air to APH Temp In C Tsai 34
Secondary Air from APH Temp Out C Tsao 325
Total Secondary Air Flow T/hr Fsa 450
Total Primary Air Flow T/hr Fpa 250
Design Ambient / Ref Air Temp C Tref 30
05/08/19 54Manohar Tatwawadi
Computations
Losses - Test Conditions Unit Symbol Value
Dry Gas Loss
= Sh*100/(Gcv*4.186) % Ldg 4.617
Carbon in fuel % Ca 36.4
Sulfur in fuel % S 0.6
Carbon in ash / kg of fuel kg/kg coal U 0.00225
Specific heat of gas kg/kg/C Cp 30.6
Avg. Flue Gas Temp - APH Out C Tgo 135
Unburnt C in ash = Pfa/100*Cfa + Pba/100*Cba % Cash 0.56
C in ash / kg of coal = A/100*Cash/(100-Cash) kg U 0.00225
Total air flow = SA + PA flow T/hr Fta 700
Ratio SA flow to Total Air flow=Fsa/Fta % Rsa 0.64
Ratio PA flow to Total Air flow=Fpa/Fta % Rpa 0.36
Weighted Temp Air In = Tsai*Rsa + Tpai*Rpa C Trai 36.1
Weighted Temp Air Out = Tsao*Rsa + Tpao*Rpa C Tao 325
05/08/19 55Manohar Tatwawadi
Avg. Flue Gas CO2 - APH Out % CO2out 14.3
Gross CV kcal/kg Gcv 3315.2
Weight of dry gas = (Ca+S/2.67-
100*U)/(12*CO2out) kg/kg coal Wd 0.2121
Sensible Heat dry gas = Wd*30.6(Tgo-Trai) kJ/kg Sh 641.66
Loss due to Unburnt Carbon
= U*CVc*100/Gcv % Luc 0.55
Carbon in Ash / kg of coal kg/kg coal U 0.00225
CV of Carbon kcal/kg CVc 8077.8
Gross CV kcal/kg Gcv 3320
Loss due to moisture in fuel
= Sw*M/(Gcv*4.186) % Lmf 2.284
Moisture in Fuel % M 12.2
Avg. Flue Gas Temp - APH Out C Tgo 135
Weighted Temp Air - APH In C Tai 36.1
Gross CV kcal/kg Gcv 3320.0
Sensible heat of water vapour Sw = 1.88*(Tgo-
25)+2442+4.2*(25-Trai) kJ/kg Sw 2602
05/08/19 56Manohar Tatwawadi
Loss due to Hydrogen in Fuel
=9*H*Sw/(Gcv*4.186) % Lhf 4.72
Hydrogen in fuel % H 2.8
Loss due to Carbon monoxide
= COoutp*7*Cvco*(Ca-100*U) /3 /
(CO2out+Cooutp) / Gcv % Lco 0.021
Avg. Flue Gas CO2 - APH Out % CO2out 14.3
Avg. Flue Gas CO - APH Out % Cooutp 0.005
Carbon in fuel % Ca 36.4
CV of Carbon Monoxide kcal/kg CVco 2415
Gross CV kcal/kg Gcv 3320
Carbon in Ash / kg of coal kg/kg coal U 0.0023
05/08/19 57Manohar Tatwawadi
Loss due to moisture in air
= Ma*1.88*(Tgo-Trai)*100/(Gcv*4.186) % Lma 0.139
Carbon in fuel % Ca 36.4
Hydrogen in fuel % H 2.8
Sulfur in fuel % S 0.6
Oxygen in fuel % O 7
Carbon in ash / kg of fuel kg/kg coal U 0.0023
Gross CV kcal/kg Gcv 3320
Moisture in Air (from Psychrometric Chart) kg/kg Mwv 0.0165
Ref.air temp C Trai 36.14
Avg. Flue Gas Temp - APH Out C Tgo 135
Avg. Flue Gas O2 - APH Out % O2out 5
Avg. Flue Gas N2 - APH Out = 100 - (O2out-
CO2out-Cooutp) % N2out 80.7
Stoichiometric air = (2.66*(C-
U*100)+7.937*H+0.996*S-O)/23.2 kg/kg coal Sa 4.83
Excess Air = 1+[(O2out-Cooutp/2)]/[0.2682*N-
(O2out-Cooutp)] Ea 1.30
Total Moisture in air = Sa*Ea*Mwv % Ma 0.1036
05/08/19 58Manohar Tatwawadi
Gas Temp Leaving AH - Corr to design ambient
Ambient Temp - test C Tad 30
Ambient Temp - design C Tadd 30
Ref. Air Temp - test C Trai 36.14
Ref. Air Temp - design C Trad 36.14
=Tadd+(Trai-Tad)
Gas Temp entering AH - test C Tgi 350
Gas Temp leaving AH - test C Tgo 135
Gas Temp leaving AH (Corr) C Tgc 135.00
=(Trad*(Tgi-Tgo)+Tgi*(Tgo-Trai)) /
(Tgi-Trai)
05/08/19 59Manohar Tatwawadi
Loss due to moisture in air
= Mad*1.88*(Tgc-Trad)*100/(Gcvd*4.186) % Lmac 0.107
Carbon in fuel - design % Cd 37
Hydrogen in fuel - design % Hd 2.3
Sulfur in fuel - design % Sd 0.3
Oxygen in fuel - design % Od 7.6
Carbon in ash / kg of fuel kg/kg coal U 0.0023
Gross CV - design kcal/kg cvd 3300
Moisture in Air (from Psychrometric Chart) kg/kg Mwvd 0.013
Ref.air temp - design C Trad 36.143
Avg. Flue Gas Temp - APH Out (Corr) C Tgc 135.00
Avg. Flue Gas O2 - APH Out % O2out 5
Avg. Flue Gas N2 - APH Out = 100 - (O2out-CO2out-
Cooutp) % N2out 80.7
Stoichiometric air = (2.66*(Cd-
U*100)+7.937*Hd+0.996*Sd-Od)/23.2 kg/kg coal Sad 4.69
Excess Air = 1+[(O2out-Cooutp/2)]/[0.2682*N2out-
(O2out-Cooutp)] Ead 1.30
Total Moisture in air = Sad*Ead*Mwvd % Mad 0.0792
05/08/19 60Manohar Tatwawadi
THANKS
05/08/19 61Manohar Tatwawadi

More Related Content

What's hot

Effect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / MillsEffect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / MillsManohar Tatwawadi
 
TPS EFFICIENCY AND HEAT RATE
TPS EFFICIENCY AND HEAT RATE TPS EFFICIENCY AND HEAT RATE
TPS EFFICIENCY AND HEAT RATE Manohar Tatwawadi
 
Boiler Efficiency Calculation by Direct & Indirect Method
Boiler Efficiency Calculation by Direct & Indirect MethodBoiler Efficiency Calculation by Direct & Indirect Method
Boiler Efficiency Calculation by Direct & Indirect MethodTahoor Alam Khan
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticPichai Chaibamrung
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlHossam Zein
 
Hp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbinesHp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbinesBoben Anto Chemmannoor
 
Power Plant Simulator Day 3 Part 5
Power Plant Simulator Day 3 Part 5Power Plant Simulator Day 3 Part 5
Power Plant Simulator Day 3 Part 5Manohar Tatwawadi
 
The Coal mill performance monitoring
The Coal mill performance monitoringThe Coal mill performance monitoring
The Coal mill performance monitoringManohar Tatwawadi
 
Steam Turbine Performance in TPS
Steam Turbine Performance in TPSSteam Turbine Performance in TPS
Steam Turbine Performance in TPSManohar Tatwawadi
 
Auxiliary power consumption reduction
Auxiliary power consumption reductionAuxiliary power consumption reduction
Auxiliary power consumption reductionAmit jangra
 
Coal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plantsCoal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plantsSHIVAJI CHOUDHURY
 
Thermal Power Plant Simulator, Cold, warm and Hot rolling of Steam Turbine
Thermal Power Plant Simulator, Cold, warm and Hot rolling of Steam TurbineThermal Power Plant Simulator, Cold, warm and Hot rolling of Steam Turbine
Thermal Power Plant Simulator, Cold, warm and Hot rolling of Steam TurbineManohar Tatwawadi
 
Training material for air preheater
Training material for air preheaterTraining material for air preheater
Training material for air preheaterHOANG VAN DUC
 
TPS Coal Mills and Fan Performance
TPS Coal Mills and Fan PerformanceTPS Coal Mills and Fan Performance
TPS Coal Mills and Fan PerformanceManohar Tatwawadi
 
Principle of operation bowl mill
Principle of operation bowl millPrinciple of operation bowl mill
Principle of operation bowl millDevidutta Panda
 
Boiler efficiency by loss Method
Boiler efficiency by loss MethodBoiler efficiency by loss Method
Boiler efficiency by loss MethodRajeev Saini
 

What's hot (20)

Heat rate of coal fired power plant
Heat rate of coal fired power plantHeat rate of coal fired power plant
Heat rate of coal fired power plant
 
Effect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / MillsEffect of Coal Quality and Performance of Coal pulverisers / Mills
Effect of Coal Quality and Performance of Coal pulverisers / Mills
 
TPS EFFICIENCY AND HEAT RATE
TPS EFFICIENCY AND HEAT RATE TPS EFFICIENCY AND HEAT RATE
TPS EFFICIENCY AND HEAT RATE
 
Boiler Efficiency Calculation by Direct & Indirect Method
Boiler Efficiency Calculation by Direct & Indirect MethodBoiler Efficiency Calculation by Direct & Indirect Method
Boiler Efficiency Calculation by Direct & Indirect Method
 
Steam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnosticSteam Condenser performance and loss diagnostic
Steam Condenser performance and loss diagnostic
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater control
 
Boiler light up & loading
Boiler light up & loadingBoiler light up & loading
Boiler light up & loading
 
Hp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbinesHp/ lp bypass system for steam turbines
Hp/ lp bypass system for steam turbines
 
Power Plant Simulator Day 3 Part 5
Power Plant Simulator Day 3 Part 5Power Plant Simulator Day 3 Part 5
Power Plant Simulator Day 3 Part 5
 
The Coal mill performance monitoring
The Coal mill performance monitoringThe Coal mill performance monitoring
The Coal mill performance monitoring
 
Steam Turbine Performance in TPS
Steam Turbine Performance in TPSSteam Turbine Performance in TPS
Steam Turbine Performance in TPS
 
Auxiliary power consumption reduction
Auxiliary power consumption reductionAuxiliary power consumption reduction
Auxiliary power consumption reduction
 
Coal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plantsCoal mill pulverizer in thermal power plants
Coal mill pulverizer in thermal power plants
 
Thermal Power Plant Simulator, Cold, warm and Hot rolling of Steam Turbine
Thermal Power Plant Simulator, Cold, warm and Hot rolling of Steam TurbineThermal Power Plant Simulator, Cold, warm and Hot rolling of Steam Turbine
Thermal Power Plant Simulator, Cold, warm and Hot rolling of Steam Turbine
 
Air heater
Air heaterAir heater
Air heater
 
Training material for air preheater
Training material for air preheaterTraining material for air preheater
Training material for air preheater
 
TPS Coal Mills and Fan Performance
TPS Coal Mills and Fan PerformanceTPS Coal Mills and Fan Performance
TPS Coal Mills and Fan Performance
 
Principle of operation bowl mill
Principle of operation bowl millPrinciple of operation bowl mill
Principle of operation bowl mill
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boiler
 
Boiler efficiency by loss Method
Boiler efficiency by loss MethodBoiler efficiency by loss Method
Boiler efficiency by loss Method
 

Similar to Air Heater and PF Boiler Performance Indices

197264747 104999991-aph-performance-improvements
197264747 104999991-aph-performance-improvements197264747 104999991-aph-performance-improvements
197264747 104999991-aph-performance-improvementshomeworkping3
 
Cooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpurCooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpurBhanupratap Niranjan
 
Boiler Efficiency.pptx
Boiler Efficiency.pptxBoiler Efficiency.pptx
Boiler Efficiency.pptxSourav Bhunia
 
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANTENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANTManohar Tatwawadi
 
Fox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services
 
Training presentation
Training presentation Training presentation
Training presentation Keyur Patel
 
Factors Affecting Boiler Performance
Factors Affecting Boiler PerformanceFactors Affecting Boiler Performance
Factors Affecting Boiler PerformanceManohar Tatwawadi
 
STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...
STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...
STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...IAEME Publication
 
2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...
2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...
2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...Komandur Sunder Raj, P.E.
 
Energy audit boiler and steam lines
Energy audit  boiler and steam linesEnergy audit  boiler and steam lines
Energy audit boiler and steam linesRohil Kumar
 
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS STedyChriswanda1
 
API Fired Heater Safety Study Report
API Fired Heater Safety Study ReportAPI Fired Heater Safety Study Report
API Fired Heater Safety Study ReportHeaterSIM
 
Handbook_of_Mechanical_Engineering_calcc
Handbook_of_Mechanical_Engineering_calccHandbook_of_Mechanical_Engineering_calcc
Handbook_of_Mechanical_Engineering_calccRAULCARDENASHUAMAN
 
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Belilove Company-Engineers
 
Performance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantPerformance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantIAEME Publication
 
HVAC operation and safety in industry.pptx
HVAC operation and safety in industry.pptxHVAC operation and safety in industry.pptx
HVAC operation and safety in industry.pptxEngr. Md. Zakirul Islam
 
Energy audit & conservation studies for industries
Energy audit & conservation studies for industriesEnergy audit & conservation studies for industries
Energy audit & conservation studies for industriesravindradatar
 

Similar to Air Heater and PF Boiler Performance Indices (20)

197264747 104999991-aph-performance-improvements
197264747 104999991-aph-performance-improvements197264747 104999991-aph-performance-improvements
197264747 104999991-aph-performance-improvements
 
Cooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpurCooling system by Bhanupratap Niranjan IIT kanpur
Cooling system by Bhanupratap Niranjan IIT kanpur
 
Boiler Efficiency.pptx
Boiler Efficiency.pptxBoiler Efficiency.pptx
Boiler Efficiency.pptx
 
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANTENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
ENERGY AUDIT METHODOLOGY FOR TURBINE CYCLE IN A POWER PLANT
 
Fox Commercial Services PMA Presentation
Fox Commercial Services PMA PresentationFox Commercial Services PMA Presentation
Fox Commercial Services PMA Presentation
 
Paper 11 icaer_2013modified
Paper 11 icaer_2013modifiedPaper 11 icaer_2013modified
Paper 11 icaer_2013modified
 
Training presentation
Training presentation Training presentation
Training presentation
 
Factors Affecting Boiler Performance
Factors Affecting Boiler PerformanceFactors Affecting Boiler Performance
Factors Affecting Boiler Performance
 
STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...
STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...
STUDY OF PERFORMANCE EVALUATION OF DOMESTIC REFRIGERATOR WORKING WITH MIXTURE...
 
2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...
2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...
2003 ASME Power Conference Performance Evaluation of Feedwater Heaters for Nu...
 
Experimental Analysis of an Regenerative Air Preheater In Boiler TPS- 1 Expan...
Experimental Analysis of an Regenerative Air Preheater In Boiler TPS- 1 Expan...Experimental Analysis of an Regenerative Air Preheater In Boiler TPS- 1 Expan...
Experimental Analysis of an Regenerative Air Preheater In Boiler TPS- 1 Expan...
 
Energy audit boiler and steam lines
Energy audit  boiler and steam linesEnergy audit  boiler and steam lines
Energy audit boiler and steam lines
 
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S4DES-7; R404A; t0 -5; tc 45.pdf for CS S
4DES-7; R404A; t0 -5; tc 45.pdf for CS S
 
API Fired Heater Safety Study Report
API Fired Heater Safety Study ReportAPI Fired Heater Safety Study Report
API Fired Heater Safety Study Report
 
Handbook_of_Mechanical_Engineering_calcc
Handbook_of_Mechanical_Engineering_calccHandbook_of_Mechanical_Engineering_calcc
Handbook_of_Mechanical_Engineering_calcc
 
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
Process Heaters, Furnaces and Fired Heaters: Improving Efficiency and Reducin...
 
Performance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantPerformance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plant
 
Energy audit of boiler
Energy audit of boilerEnergy audit of boiler
Energy audit of boiler
 
HVAC operation and safety in industry.pptx
HVAC operation and safety in industry.pptxHVAC operation and safety in industry.pptx
HVAC operation and safety in industry.pptx
 
Energy audit & conservation studies for industries
Energy audit & conservation studies for industriesEnergy audit & conservation studies for industries
Energy audit & conservation studies for industries
 

More from Manohar Tatwawadi

Frequently Asked Questions on TURBINE Part 3
Frequently Asked Questions on TURBINE Part 3Frequently Asked Questions on TURBINE Part 3
Frequently Asked Questions on TURBINE Part 3Manohar Tatwawadi
 
Green building concepts and good building practices
Green building concepts and good building practicesGreen building concepts and good building practices
Green building concepts and good building practicesManohar Tatwawadi
 
Auxiliary Consumption and Saving due to Increase in Boiler Efficiency
Auxiliary Consumption and Saving due to Increase in Boiler EfficiencyAuxiliary Consumption and Saving due to Increase in Boiler Efficiency
Auxiliary Consumption and Saving due to Increase in Boiler EfficiencyManohar Tatwawadi
 
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIESCOMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIESManohar Tatwawadi
 
Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1Manohar Tatwawadi
 
Cooling towers in thermal power plants
Cooling towers in thermal power plantsCooling towers in thermal power plants
Cooling towers in thermal power plantsManohar Tatwawadi
 
Electrical safety in power stations
Electrical safety in power stationsElectrical safety in power stations
Electrical safety in power stationsManohar Tatwawadi
 
Cost accounting, cost control and cost reduction in TPS
Cost accounting, cost control and cost reduction in TPSCost accounting, cost control and cost reduction in TPS
Cost accounting, cost control and cost reduction in TPSManohar Tatwawadi
 
Environmental and pollution control in Thermal Power Stations
Environmental and pollution control in Thermal Power StationsEnvironmental and pollution control in Thermal Power Stations
Environmental and pollution control in Thermal Power StationsManohar Tatwawadi
 
Energy Audit & Energy Conservation Opportunities in Electrical Equipments ...
Energy Audit & Energy  Conservation  Opportunities in  Electrical Equipments ...Energy Audit & Energy  Conservation  Opportunities in  Electrical Equipments ...
Energy Audit & Energy Conservation Opportunities in Electrical Equipments ...Manohar Tatwawadi
 
Fuels and Combustion Equations
Fuels and Combustion EquationsFuels and Combustion Equations
Fuels and Combustion EquationsManohar Tatwawadi
 
Basics of thermal power stations
Basics of thermal power stationsBasics of thermal power stations
Basics of thermal power stationsManohar Tatwawadi
 
Handling of turbine during emergencies
Handling of turbine during emergenciesHandling of turbine during emergencies
Handling of turbine during emergenciesManohar Tatwawadi
 
Thermal power plant efficiency
Thermal power plant efficiencyThermal power plant efficiency
Thermal power plant efficiencyManohar Tatwawadi
 
210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rateManohar Tatwawadi
 
THERMAL POWER PLANT EFFICIENCY AND HEAT RATE
THERMAL POWER PLANT EFFICIENCY AND HEAT RATETHERMAL POWER PLANT EFFICIENCY AND HEAT RATE
THERMAL POWER PLANT EFFICIENCY AND HEAT RATEManohar Tatwawadi
 

More from Manohar Tatwawadi (20)

Power Plant Operations.pdf
Power Plant Operations.pdfPower Plant Operations.pdf
Power Plant Operations.pdf
 
Frequently Asked Questions on TURBINE Part 3
Frequently Asked Questions on TURBINE Part 3Frequently Asked Questions on TURBINE Part 3
Frequently Asked Questions on TURBINE Part 3
 
Green building concepts and good building practices
Green building concepts and good building practicesGreen building concepts and good building practices
Green building concepts and good building practices
 
Auxiliary Consumption and Saving due to Increase in Boiler Efficiency
Auxiliary Consumption and Saving due to Increase in Boiler EfficiencyAuxiliary Consumption and Saving due to Increase in Boiler Efficiency
Auxiliary Consumption and Saving due to Increase in Boiler Efficiency
 
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIESCOMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
COMPRESSED AIR SYSTEM . ENERGY CONSERVATION OPPORTUNITIES
 
FAQ on Turbines Part 2
FAQ on Turbines Part 2FAQ on Turbines Part 2
FAQ on Turbines Part 2
 
Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1Frequently asked questions on turbines Part 1
Frequently asked questions on turbines Part 1
 
Cooling towers in thermal power plants
Cooling towers in thermal power plantsCooling towers in thermal power plants
Cooling towers in thermal power plants
 
Electrical safety in power stations
Electrical safety in power stationsElectrical safety in power stations
Electrical safety in power stations
 
Cost accounting, cost control and cost reduction in TPS
Cost accounting, cost control and cost reduction in TPSCost accounting, cost control and cost reduction in TPS
Cost accounting, cost control and cost reduction in TPS
 
Environmental and pollution control in Thermal Power Stations
Environmental and pollution control in Thermal Power StationsEnvironmental and pollution control in Thermal Power Stations
Environmental and pollution control in Thermal Power Stations
 
Energy Audit & Energy Conservation Opportunities in Electrical Equipments ...
Energy Audit & Energy  Conservation  Opportunities in  Electrical Equipments ...Energy Audit & Energy  Conservation  Opportunities in  Electrical Equipments ...
Energy Audit & Energy Conservation Opportunities in Electrical Equipments ...
 
Fuels and Combustion Equations
Fuels and Combustion EquationsFuels and Combustion Equations
Fuels and Combustion Equations
 
Basics of thermal power stations
Basics of thermal power stationsBasics of thermal power stations
Basics of thermal power stations
 
Handling of turbine during emergencies
Handling of turbine during emergenciesHandling of turbine during emergencies
Handling of turbine during emergencies
 
Thermal power plant efficiency
Thermal power plant efficiencyThermal power plant efficiency
Thermal power plant efficiency
 
210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rate
 
THERMAL POWER PLANT EFFICIENCY AND HEAT RATE
THERMAL POWER PLANT EFFICIENCY AND HEAT RATETHERMAL POWER PLANT EFFICIENCY AND HEAT RATE
THERMAL POWER PLANT EFFICIENCY AND HEAT RATE
 
Biomass Power Plants
Biomass Power PlantsBiomass Power Plants
Biomass Power Plants
 
Swot Analysis
Swot AnalysisSwot Analysis
Swot Analysis
 

Recently uploaded

Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)Suman Mia
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Dr.Costas Sachpazis
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130Suhani Kapoor
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCall Girls in Nagpur High Profile
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingrakeshbaidya232001
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...ranjana rawat
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learningmisbanausheenparvam
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...ranjana rawat
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSRajkumarAkumalla
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxAsutosh Ranjan
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxpranjaldaimarysona
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxwendy cai
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Christo Ananth
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxupamatechverse
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur High Profile
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSKurinjimalarL3
 

Recently uploaded (20)

Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)Software Development Life Cycle By  Team Orange (Dept. of Pharmacy)
Software Development Life Cycle By Team Orange (Dept. of Pharmacy)
 
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
★ CALL US 9953330565 ( HOT Young Call Girls In Badarpur delhi NCR
 
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
Sheet Pile Wall Design and Construction: A Practical Guide for Civil Engineer...
 
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
VIP Call Girls Service Kondapur Hyderabad Call +91-8250192130
 
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service NashikCollege Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
College Call Girls Nashik Nehal 7001305949 Independent Escort Service Nashik
 
Porous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writingPorous Ceramics seminar and technical writing
Porous Ceramics seminar and technical writing
 
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
9953056974 Call Girls In South Ex, Escorts (Delhi) NCR.pdf
 
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
The Most Attractive Pune Call Girls Budhwar Peth 8250192130 Will You Miss Thi...
 
chaitra-1.pptx fake news detection using machine learning
chaitra-1.pptx  fake news detection using machine learningchaitra-1.pptx  fake news detection using machine learning
chaitra-1.pptx fake news detection using machine learning
 
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
(ANJALI) Dange Chowk Call Girls Just Call 7001035870 [ Cash on Delivery ] Pun...
 
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICSHARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
HARDNESS, FRACTURE TOUGHNESS AND STRENGTH OF CERAMICS
 
Coefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptxCoefficient of Thermal Expansion and their Importance.pptx
Coefficient of Thermal Expansion and their Importance.pptx
 
Processing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptxProcessing & Properties of Floor and Wall Tiles.pptx
Processing & Properties of Floor and Wall Tiles.pptx
 
What are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptxWhat are the advantages and disadvantages of membrane structures.pptx
What are the advantages and disadvantages of membrane structures.pptx
 
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptxExploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
Exploring_Network_Security_with_JA3_by_Rakesh Seal.pptx
 
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
Call for Papers - African Journal of Biological Sciences, E-ISSN: 2663-2187, ...
 
Introduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptxIntroduction and different types of Ethernet.pptx
Introduction and different types of Ethernet.pptx
 
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCRCall Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
Call Us -/9953056974- Call Girls In Vikaspuri-/- Delhi NCR
 
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur EscortsCall Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
Call Girls in Nagpur Suman Call 7001035870 Meet With Nagpur Escorts
 
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICSAPPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
APPLICATIONS-AC/DC DRIVES-OPERATING CHARACTERISTICS
 

Air Heater and PF Boiler Performance Indices

  • 1. Presentation Coverage Air Heater & Boiler Performance Indices Improvements in Measurements - Case Studies Calculation of Boiler Efficiency - Sample Calculations 05/08/19 1Manohar Tatwawadi
  • 2. Air Heater - Performance Indicators • Air-in-Leakage • Gas Side Efficiency • Heat X - ratio • Flue gas temperature drop • Air side temperature rise • Gas & Air side pressure drops (The indices are affected by changes in entering air or gas temperatures, their flow quantities and coal moisture) 05/08/19 2Manohar Tatwawadi
  • 3. AH Performance Monitoring • O2 & CO2 in FG at AH Inlet • O2 & CO2 in FG at AH Outlet • Temperature of gas entering / leaving air heater • Temperature of air entering / leaving air heater • Diff. Pressure across AH on air & gas side (Above data is tracked to monitor AH performance) 05/08/19 3Manohar Tatwawadi
  • 4. Air heater Air-in-leakage All units that operate with a rotary type regenerative air heater experience some degree of air leakage across the air heater seals. An increase in air leakage across the seals of an AH results in increased ID and FD fan power and flow rate of flue gas. Sometimes it can put limitations on unit loading as well. Typically air heater starts with a baseline leakage of 8 to 10% after an overhaul. 05/08/19 4Manohar Tatwawadi
  • 5. Air Heater Leakage (%) The leakage of the high pressure air to the low pressure flue gas is due to the Differential Pressure between fluids, increased seal clearances in hot condition, seal erosion / improper seal settings. Increased AH leakage leads to • Reduced AH efficiency • Increased fan power consumption • Higher gas velocities that affect ESP performance • Loss of fan margins leading to inefficient operation and at times restricting unit loading 05/08/19 5Manohar Tatwawadi
  • 6. Air Heater Leakage (%) • Direct - Hot End / Cold End (60% through radial seals + 30% through Circumferential bypass) Air leakage occurring at the hot end of the air heater affects its thermal and hydraulic performance while cold end leakage increases fans loading. • Entrained Leakage due to entrapped air between the heating elements (depends on speed of rotation & volume of rotor air space) 05/08/19 6Manohar Tatwawadi
  • 7. Rotary Air heater RADIAL SEAL AXIAL SEAL BYPASS SEAL COLD END HOT END HOT INTERMEDIATE 05/08/19 7Manohar Tatwawadi
  • 10. Flexible seal assembly - Cold Condition 05/08/19 10Manohar Tatwawadi
  • 11. Flexible seal assembly - Hot Condition 05/08/19 11Manohar Tatwawadi
  • 12. Leakage Assessment • Leakage assessment must be done by a grid survey using a portable gas analyser. • Calculation of leakage using CO2 values is preferred because of higher absolute values and lower errors. • Method of determination of O2 or CO2 should be the same at inlet and outlet - wet or dry (Orsat) • Single point O2 measurement feedback using orsat is on dry basis while zirconia measurement is on wet basis. • Leakage assessment is impacted by air ingress from expansion joints upstream of measurement sections. 05/08/19 12Manohar Tatwawadi
  • 13. Air Heater Leakage (%) Weight of air passing from air side to gas side This leakage is assumed to occur entirely between air inlet and gas outlet 05/08/19 13Manohar Tatwawadi
  • 14. Air Heater Leakage - Calculation Empirical relationship using the change in concentration of O2 or CO2 in the flue gas = CO2in - CO2out * 0.9 * 100 CO2out = O2out - O2in * 0.9 * 100 = 5.7 – 2.8 * 90 (21- O2out) (21-5.7) = 17.1 % CO2 measurement is preferred due to high absolute values; In case of any measurement errors, the resultant influence on leakage calculation is small. 05/08/19 14Manohar Tatwawadi
  • 15. Gas Side Efficiency Ratio of Gas Temperature drop across the air heater, corrected for no leakage, to the temperature head. = (Temp drop / Temperature head) * 100 where Temp drop = Tgas in -Tgas out (no leakage) Temp head = Tgasin - T air in Gas Side Efficiency = (333.5-150.5) / (333.5-36.1) = 61.5 % 05/08/19 15Manohar Tatwawadi
  • 16. Tgas out (no leakage) = The temperature at which the gas would have left the air heater if there were no AH leakage = AL * Cpa * (Tgas out - Tair in) + Tgas out Cpg * 100 Say AH leakage – 17.1%, Gas In Temp – 333.5 C, Gas Out Temp – 133.8 C, Air In Temp – 36.1 C Tgasnl = 17.1 * (133.8 – 36.1) + 133.8 = 150.5 C 100 05/08/19 16Manohar Tatwawadi
  • 17. HEAT X – Ratio Ratio of heat capacity of air passing through the air heater to the heat capacity of flue gas passing through the air heater. = Wair out * Cpa Wgas in * Cpg = Tgas in - Tgas out (no leakage) Tair out - Tair in Say AH leakage – 17.1%, Gas In Temp – 333.5 C, Gas Out Temp – 133.8 C , Air In Temp – 36.1 C, Air Out Temp – 288 C X ratio = (333.5 – 150.5) / (288 –36.1) = 0.73 05/08/19 17Manohar Tatwawadi
  • 18. X-Ratio depends on • moisture in coal, air infiltration, air & gas mass flow rates • leakage from the setting • specific heats of air & flue gas X-ratio does not provide a measure of thermal performance of the air heater, but is a measure of the operating conditions. A low X-ratio indicates either excessive gas weight through the air heater or that air flow is bypassing the air heater. A lower than design X-ratio leads to a higher than design gas outlet temperature & can be used as an indication of excessive tempering air to the mills or excessive boiler setting infiltration. 05/08/19 18Manohar Tatwawadi
  • 19. Pressure drops across air heater • Air & gas side pressure drops change approximately in proportion to the square of the gas & air weights through the air heaters. • If excess air is greater than expected, the pressure drops will be greater than expected. • Deposits / choking of the basket elements would lead to an increase in pressure drops • Pressure drops also vary directly with the mean absolute temperatures of the fluids passing through the air heaters due to changes in density. 05/08/19 19Manohar Tatwawadi
  • 20. Air Ingress Calculations Air ingress quantification is done with the same formulae as those used for calculation of AH leakage Air ingress = O2out - O2in * 0.9 * 100 = 6.5 - 5.7 * 90 (21- O2out) 21 - 6.5 = 4.96 % The basis of O2 or CO2 calculation should be the same – either wet or dry. 05/08/19 20Manohar Tatwawadi
  • 21. Air Heaters Temp measurements • Thermocouples for flue gas temperatures at AH inlet as well as exit are generally clustered on one side. • A grid survey is needed for representative values. • Exit gas temperatures need to be corrected to a reference ambient and to no leakage conditions for comparison. • Thermocouples for SA temperature measurement at AH outlet are mounted too close to air heaters and need to be relocated downstream to avoid duct stratification. • Additional mill or changes in coal quality change thermal performance of a tri-sector air heater in a very major way; performance evaluation is difficult.05/08/19 21Manohar Tatwawadi
  • 22. Flue gas temperature as measured in common ducts leading to ESPs in 500 MW units is more representative than weighted averages of temperatures measured at individual AH exits. Flue Gas Temperatures C T 3 T 4 T 9 T 11 T 14 PAPH A Outlet 142.7 133.2 145.7 139.1 139.9 SAPH A Outlet 132.5 133.1 139.8 138.1 137.0 Eqv. Temp A side 135.9 133.1 141.7 138.5 138.0 Grid Average Left 141.8 146.5 147.3 144.1 143.6 PAPH B Outlet 142.2 134.5 143.9 137.9 149.5 SAPH B Outlet 135.9 132.4 139.6 136.2 143.2 Eqv. Temp B side 138.0 133.1 141.0 136.7 145.3 Grid Average Right 144.0 147.5 149.9 148.4 150.4 Flue Gas Temperature at AH outlet 05/08/19 22Manohar Tatwawadi
  • 23. Boiler Performance Boiler Efficiency The % of heat input to the boiler absorbed by the working fluid (Typically 85-88%) 05/08/19 23Manohar Tatwawadi
  • 24. Boiler Efficiency… Boiler Efficiency can be determined by a) Direct method or Input / Output method b) Indirect method or Loss method 05/08/19 24Manohar Tatwawadi
  • 26. Boiler Efficiency… Direct method or Input / Output method measures the heat absorbed by water & steam & compares it with the total energy input based on HHV of fuel. • Direct method is based on fuel flow, GCV, steam flow pressure & temperature measurements. For coal fired boilers, it’s difficult to accurately measure coal flow and heating value on real time basis. • Another problem with direct method is that the extent and nature of the individual components losses is not quantified. 05/08/19 26Manohar Tatwawadi
  • 27. Boiler Efficiency… Indirect method or Loss method For utility boilers efficiency is generally calculated by heat loss method wherein the component losses are calculated and subtracted from 100. Boiler Efficiency = 100 - Losses in % 05/08/19 27Manohar Tatwawadi
  • 28. Indirect Method Boiler Flue gas Efficiency = 100 – (1+2+3+4+5+6+7+8) Fuel + Air 1. Dry Flue gas loss 2. H2 loss 3. Moisture in fuel 4. Moisture in air 5. CO loss 7. Fly ash loss 6. Radiation 8. Bottom ash loss WaterSteam 05/08/19 28Manohar Tatwawadi
  • 29. Indirect or Loss method • In Heat Loss method the unit of heat input is the higher heating value per kg of fuel. Heat losses from various sources are summed & expressed per kg of fuel fired. Efficiency = 100 – (L/Hf) * 100 L – losses Hf – heat input 05/08/19 29Manohar Tatwawadi
  • 30. Indirect or Loss method • This method also requires accurate determination of heating value, but since the total losses make a relatively small portion of the total heat input (~ 13 %), an error in measurement does not appreciably affect the efficiency calculations. • In addition to being more accurate for field testing, the heat loss method identifies exactly where the heat losses are occurring. 05/08/19 30Manohar Tatwawadi
  • 31. Boiler Efficiency… Commonly used standards for boiler performance testing are ASME PTC 4 (1998) BS – 2885 (1974) IS: 8753: 1977 DIN standards 05/08/19 31Manohar Tatwawadi
  • 32. arameters required for computing Boiler Efficiency AH flue gas outlet O2 / CO2 / CO AH flue gas inlet and outlet temp C Primary / Secondary air temp at AH inlet / outlet C Total Airflow / Secondary Air Flow t/hr Dry/Wet bulb temperatures C Ambient pressure bar a Proximate Analysis & GCV of Coal kcal / kg Combustibles in Bottom Ash and Flyash 05/08/19 32Manohar Tatwawadi
  • 33. Boiler Losses Typical values Dry Gas Loss 5.21 Unburnt Loss 0.63 Hydrogen Loss 4.22 Moisture in Fuel Loss 2.00 Moisture in Air Loss 0.19 Carbon Monoxide Loss 0.11 Radiation/Unaccounted Loss 1.00 Boiler Efficiency 86.63 05/08/19 33Manohar Tatwawadi
  • 34. Effect of Operating Parameters on Boiler Losses 05/08/19 34Manohar Tatwawadi
  • 35. Dry Gas Loss (Controllable) • This is the heat carried away by flue gas at AH outlet • It’s a function of flue gas quantity and the temperature difference between air heater exit gas temperature and FD fan inlet air temperature • Typically 20 C increase in exit gas temperature ~ 1% reduction in boiler efficiency. 05/08/19 35Manohar Tatwawadi
  • 36. Dry Gas Loss… Sensible Heat of flue gas (Sh) Sh = Mass of dry flue gas X Sp. Heat X (Tfg – Tair) Dry Flue Gas Loss % = (Sh / GCV of Fuel) * 100 05/08/19 36Manohar Tatwawadi
  • 37. Dry Gas loss reduction requires • Boiler operation at optimum excess air • Cleanliness of boiler surfaces • Good combustion of fuel • Reduction of tempering air to mill. • Reduction in air ingress • Cleaning of air heater surfaces and proper heating elements / surface area 05/08/19 37Manohar Tatwawadi
  • 38. Unburnt Carbon Loss (Controllable) • The amount of unburnt is a measure of effectiveness of combustion process in general and mills / burners in particular. • Unburnt carbon includes the unburned constituents in flyash as well as bottom ash. • Ratio of Flyash to Bottom ash is around 80:20 • Focus to be on flyash due to uncertainty in repeatability and representative ness of unburnt carbon in bottom ash • +50 PF fineness fractions to be < 1-1.5%05/08/19 38Manohar Tatwawadi
  • 39. Unburnt Carbon Loss (Controllable) Loss due to Unburnt Carbon = U * CVc * 100 / GCV of Coal CVc – CV of Carbon 8077.8 kcal/kg U = Carbon in ash / kg of coal = Ash * C (Carbon in coal) 100 100 - C 05/08/19 39Manohar Tatwawadi
  • 40. Influencing Factors - Unburnt Carbon Loss • Type of mills and firing system • Furnace size • Coal FC/VM ratio, coal reactivity • Burners design / condition • PF fineness (Pulveriser problems) • Insufficient excess air in combustion zone • Air damper / register settings • Burner balance / worn orifices • Primary Air Flow / Pressure 05/08/19 40Manohar Tatwawadi
  • 41. CO Loss (Controllable) • Ideally, average CO at gooseneck after combustion completion should be below 100 ppm and no single value over 200 ppm • CO monitors at ID fan discharge in all boilers to supplement O2 feedback C + O2 = CO2 + 8084 kcal / kg of Carbon 2C+ O2 = 2CO + 2430 kcal / kg of Carbon 2H2+ O2 = 2H2O + 28922 kcal / kg of Hydrogen S + O2 = SO2 + 2224 kcal / kg of Sulphur (We lose 5654 kcal for each kg of CO formed) 05/08/19 41Manohar Tatwawadi
  • 42. Moisture Loss Fuel Hydrogen Loss This loss is due to combustion of H present in fuel. H is burnt and converted in water, which gets evaporated. Fuel Moisture Loss This loss is due to evaporation and heating of inherent and surface moisture present in fuel. (Can be reduced by judicious sprays in coal yards) 05/08/19 42Manohar Tatwawadi
  • 43. Computation - Moisture Loss Total Moisture Loss = (9H+M) * Sw / GCV of Coal Sw – Sensible Heat of water vapour = 1.88 (Tgo – 25) + 2442 + 4.2 (25 - Trai) The moisture in flue gases (along with Sulphur in fuel) limits the temperature to which the flue gases may be cooled due to corrosion considerations in the cold end of air heater, gas ducts etc. 05/08/19 43Manohar Tatwawadi
  • 44. Other Losses 1. Sensible Heat Loss of ash • Bottom Ash Hoppers • Eco Hoppers • AH Hoppers • ESP hoppers Sensible Heat Loss (%) = (X / GCV) *100 (~0.5-0.6 %) X = [{Ash * Pflyash * C pash * (T go - T rai )} + {Ash * Pahash * C pash * (T go - T rai )} + {Ash * Peash * C pash * (T gi -T rai )} + {Ash * Pba * C pash * (T ba - T rai )}] 05/08/19 44Manohar Tatwawadi
  • 45. Other Losses 2. Radiation Loss through Bottom Ash Hopper • Coal Flow Rate 135 Tons/Hr • GCV of Coal 3300 Kcal/Kg • Eqv. Heat Flux thro’ Bottom opening 27090 Kcal/hr/m2 • Bottom opening area of S-Panel 15.85 m2 Radiation Loss through Bottom Ash Hopper = [H BOTTOM * A S-PANEL *100 ] / [Coal Flow * GCV * 1000] = 0.096 % 05/08/19 45Manohar Tatwawadi
  • 46. Other Losses 3. Coal Mill Reject Loss • Coal Flow 135 T/hr • Coal Mill Rejects 200 kg/hr • GCV of Coal 3300 kcal/Kg • CV of Rejects 900 kcal/Kg • Mill Outlet Temp Tmillout 90 C • Reference Temperature Trai 30 C • Specific Heat of Rejects CpREJECT 0.16 kcal/Kg/C Loss due to Mill Rejects = X / (Coal Flow * GCV * 1000) X = [Rejects * (CVREJECT + CpREJECT (Tmillout – Trai ))* 100 ] = (0.0408 %)05/08/19 46Manohar Tatwawadi
  • 47. Other Losses 4. Radiation Loss Actual radiation and convection losses are difficult to assess because of particular emissivity of various surfaces. 05/08/19 47Manohar Tatwawadi
  • 48. HEAT CREDIT Heat Credit due to Coal Mill Power = [MP * 859.86 * 100] / [Coal Flow * GCV * 1000] Coal Flow Rate Coal FLOW Tons/Hr Total Coal Mill Power MP kWh GCV of Coal Kcal/Kg 05/08/19 48Manohar Tatwawadi
  • 49. Computations 1. The proximate analysis of coal is used to estimate the as-fired percentages of carbon & hydrogen using ‘Parr Formula’and nitrogen using ‘Gebhardt Formula’. a) UltC = (1-0.01Z)*Cp + (5.0*FuelA) - (50.0*UltS) Where Z = FuelTM*100 + 110*FuelA + 10*UltS Qp = (100 * HHV) / (100 - Z) Vp = 100*(100*FuelVM - 10*FuelA - 10*UltS)/(100-Z) Cp = 0.0015782 * Qp - 0.2226 * Vp + 37.69   Say Fixed Carbon – 23.5, VM – 22.2, TM – 10.6, Ash 43.7 %, S – 0.4 %; Ultimate C = 34.9%05/08/19 49Manohar Tatwawadi
  • 50. b) UltH = (1-0.01Z)*Hp + (1.0*FuelA) - (1.5*UltS) Where Z = FuelTM*100 + 110*FuelA + 10*UltS Qp = (100 * HHV) / (100 - Z) Vp = 100 * (100*FuelVM-10*FuelA - 10*UltS)/(100-Z) Hp = 0.0001707 * Qp +0.0653 * Vp -2.92 Ultimate H = 2.7 % c) UltN = 2.10 - 1.2*FuelVM = 1.8 %   d) UltOAct = 100 - UltCAct + UltHAct + UltNAct + UltSAct + FuelAAct + FuelTMAct)   = 5.9 % 05/08/19 50Manohar Tatwawadi
  • 51. Proximate to Ultimate Conversion Formulae used for conversion of proximate analysis to ultimate analysis add to the uncertainty of results. For some coals, its recommended to use Seyler & Dulong formula for estimation of C & H and modified Gebardht formula for estimation of N from proximate analysis. It’s suggested to get proximate & ultimate analysis of few coal samples done to validate the formulae being used. 05/08/19 51Manohar Tatwawadi
  • 52.   2) The flue gas O2 reading from zirconia probe is based on a wet analysis. For comparison with the orsat or the test grid readings, it must be converted to a dry analysis. If the % moisture in the flue gas is unknown, a typical value of 8% can be used. O2 dry = O2 wet / (1-%Moisture/100) Say O2 dry = 3.2 / (1 – 8 / 100) = 3.48 % 05/08/19 52Manohar Tatwawadi
  • 53. Manual Inputs Units Symbol Value Unit Load MW L 210 FW Flow at Eco Inlet T/hr Ffw 615 Wet Bulb Temp C Wb 24 Dry bulb Temp C Db 30 Barometric Pressure mmHgC BP 760 Total Coal Flow T/hr Fin 140 Unburnt C in Bottom Ash % Cba 1.2 Unburnt C in Flysash % Cfa 0.4 Radiation & Unaccounted Loss % Lrad 1.2 % of Flyash to Total Ash % Pfa 80 % of Bottom ash to Total Ash % Pba 20 Ultimate Analysis - As Fired Carbon % Ca 36.4 Sulfur % S 0.6 Hydrogen % H 2.8 Moisture % M 12.2 Nitrogen % N 1 Oxygen % O 7 Ash % A 40 Gross Calorific Value kcal/kg Gcv 3320 05/08/19 53Manohar Tatwawadi
  • 54. Avg. Flue Gas O2 - APH Out % O2out 5.0 Avg. Flue Gas CO2 - APH Out % CO2out 14.3 Avg. Flue Gas CO - APH Out ppm COout 50 Avg. Flue Gas Temp - APH In C Tgi 350 Avg. Flue Gas Temp - APH Out C Tgo 135 Primary Air to APH Temp In C Tpai 40 Primary Air from APH Temp Out C Tpao 325 Secondary Air to APH Temp In C Tsai 34 Secondary Air from APH Temp Out C Tsao 325 Total Secondary Air Flow T/hr Fsa 450 Total Primary Air Flow T/hr Fpa 250 Design Ambient / Ref Air Temp C Tref 30 05/08/19 54Manohar Tatwawadi
  • 55. Computations Losses - Test Conditions Unit Symbol Value Dry Gas Loss = Sh*100/(Gcv*4.186) % Ldg 4.617 Carbon in fuel % Ca 36.4 Sulfur in fuel % S 0.6 Carbon in ash / kg of fuel kg/kg coal U 0.00225 Specific heat of gas kg/kg/C Cp 30.6 Avg. Flue Gas Temp - APH Out C Tgo 135 Unburnt C in ash = Pfa/100*Cfa + Pba/100*Cba % Cash 0.56 C in ash / kg of coal = A/100*Cash/(100-Cash) kg U 0.00225 Total air flow = SA + PA flow T/hr Fta 700 Ratio SA flow to Total Air flow=Fsa/Fta % Rsa 0.64 Ratio PA flow to Total Air flow=Fpa/Fta % Rpa 0.36 Weighted Temp Air In = Tsai*Rsa + Tpai*Rpa C Trai 36.1 Weighted Temp Air Out = Tsao*Rsa + Tpao*Rpa C Tao 325 05/08/19 55Manohar Tatwawadi
  • 56. Avg. Flue Gas CO2 - APH Out % CO2out 14.3 Gross CV kcal/kg Gcv 3315.2 Weight of dry gas = (Ca+S/2.67- 100*U)/(12*CO2out) kg/kg coal Wd 0.2121 Sensible Heat dry gas = Wd*30.6(Tgo-Trai) kJ/kg Sh 641.66 Loss due to Unburnt Carbon = U*CVc*100/Gcv % Luc 0.55 Carbon in Ash / kg of coal kg/kg coal U 0.00225 CV of Carbon kcal/kg CVc 8077.8 Gross CV kcal/kg Gcv 3320 Loss due to moisture in fuel = Sw*M/(Gcv*4.186) % Lmf 2.284 Moisture in Fuel % M 12.2 Avg. Flue Gas Temp - APH Out C Tgo 135 Weighted Temp Air - APH In C Tai 36.1 Gross CV kcal/kg Gcv 3320.0 Sensible heat of water vapour Sw = 1.88*(Tgo- 25)+2442+4.2*(25-Trai) kJ/kg Sw 2602 05/08/19 56Manohar Tatwawadi
  • 57. Loss due to Hydrogen in Fuel =9*H*Sw/(Gcv*4.186) % Lhf 4.72 Hydrogen in fuel % H 2.8 Loss due to Carbon monoxide = COoutp*7*Cvco*(Ca-100*U) /3 / (CO2out+Cooutp) / Gcv % Lco 0.021 Avg. Flue Gas CO2 - APH Out % CO2out 14.3 Avg. Flue Gas CO - APH Out % Cooutp 0.005 Carbon in fuel % Ca 36.4 CV of Carbon Monoxide kcal/kg CVco 2415 Gross CV kcal/kg Gcv 3320 Carbon in Ash / kg of coal kg/kg coal U 0.0023 05/08/19 57Manohar Tatwawadi
  • 58. Loss due to moisture in air = Ma*1.88*(Tgo-Trai)*100/(Gcv*4.186) % Lma 0.139 Carbon in fuel % Ca 36.4 Hydrogen in fuel % H 2.8 Sulfur in fuel % S 0.6 Oxygen in fuel % O 7 Carbon in ash / kg of fuel kg/kg coal U 0.0023 Gross CV kcal/kg Gcv 3320 Moisture in Air (from Psychrometric Chart) kg/kg Mwv 0.0165 Ref.air temp C Trai 36.14 Avg. Flue Gas Temp - APH Out C Tgo 135 Avg. Flue Gas O2 - APH Out % O2out 5 Avg. Flue Gas N2 - APH Out = 100 - (O2out- CO2out-Cooutp) % N2out 80.7 Stoichiometric air = (2.66*(C- U*100)+7.937*H+0.996*S-O)/23.2 kg/kg coal Sa 4.83 Excess Air = 1+[(O2out-Cooutp/2)]/[0.2682*N- (O2out-Cooutp)] Ea 1.30 Total Moisture in air = Sa*Ea*Mwv % Ma 0.1036 05/08/19 58Manohar Tatwawadi
  • 59. Gas Temp Leaving AH - Corr to design ambient Ambient Temp - test C Tad 30 Ambient Temp - design C Tadd 30 Ref. Air Temp - test C Trai 36.14 Ref. Air Temp - design C Trad 36.14 =Tadd+(Trai-Tad) Gas Temp entering AH - test C Tgi 350 Gas Temp leaving AH - test C Tgo 135 Gas Temp leaving AH (Corr) C Tgc 135.00 =(Trad*(Tgi-Tgo)+Tgi*(Tgo-Trai)) / (Tgi-Trai) 05/08/19 59Manohar Tatwawadi
  • 60. Loss due to moisture in air = Mad*1.88*(Tgc-Trad)*100/(Gcvd*4.186) % Lmac 0.107 Carbon in fuel - design % Cd 37 Hydrogen in fuel - design % Hd 2.3 Sulfur in fuel - design % Sd 0.3 Oxygen in fuel - design % Od 7.6 Carbon in ash / kg of fuel kg/kg coal U 0.0023 Gross CV - design kcal/kg cvd 3300 Moisture in Air (from Psychrometric Chart) kg/kg Mwvd 0.013 Ref.air temp - design C Trad 36.143 Avg. Flue Gas Temp - APH Out (Corr) C Tgc 135.00 Avg. Flue Gas O2 - APH Out % O2out 5 Avg. Flue Gas N2 - APH Out = 100 - (O2out-CO2out- Cooutp) % N2out 80.7 Stoichiometric air = (2.66*(Cd- U*100)+7.937*Hd+0.996*Sd-Od)/23.2 kg/kg coal Sad 4.69 Excess Air = 1+[(O2out-Cooutp/2)]/[0.2682*N2out- (O2out-Cooutp)] Ead 1.30 Total Moisture in air = Sad*Ead*Mwvd % Mad 0.0792 05/08/19 60Manohar Tatwawadi